DFA Series. Rainwater/Graywater Filtration Systems. Installation, Operation and Maintenance Manual DFM-2F-180 DFM-3F-180 DFM-3F-350
|
|
- Daniel Morris
- 5 years ago
- Views:
Transcription
1 DFA Series Rainwater/Graywater Filtration Systems MODELS: DFM-2F-180 DFM-3F-180 DFM-3F-350 DFA-2F-180 DFA-3F-180 DFA-3F-350 Installation, Operation and Maintenance Manual CAUTION: Read and Follow all safety rules and operating instructions before first use of product. DEALER NAME: DEALER PHONE #: MODEL #: SERIAL #: DATE INSTALLED: Aqua Treatment Service, Inc. 194 Hempt Road Mechanicsburg, PA
2 Aqua Treatment Service, Inc. 2012
3 Table of Contents Installation Instructions: General Safety Instructions... 2 Function / Description... 3 Installation... 4 Installation Diagram... 5 Maintenance: Electronic Control: Parts Breakdown: Control Panels... 8 Wiring Diagram... 9 Unit DFM Series Unit DFA Series Specifications: Dimensions: Troubleshooting: Warranty: Aqua Treatment Service, Inc
4 General Safety Instructions WARNING - to guard against injury, basic safety precautions should be observed, including the following: 1. READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 2. DANGER - To avoid possible electric shock, special care should be taken since water is present near electrical equipment. Unless a situation is encountered that is explicitly addressed by the provided maintenance and troubleshooting sections, do not attempt repairs yourself, refer to an authorized service facility. 1. SAVE THESE INSTRUCTIONS. 2. WARNING: Before installing the bag filter housing, check that the piping system operating conditions do not exceed their maximum pressure and temperature rating limits of the filter. 3. WARNING: CONTENTS UNDER PRESSURE!! Make sure to relieve all pressure before performing and maintenance. 3. Carefully examine the filtration system after installation. It should not be powered up if there is water on parts not intended to be wet. 4. Do not operate the filter system if it has a damaged power supply, if it is malfunctioning or if it is dropped or damaged in any manner. 5. Always shut off water flow and drain system before changing bag filters or performing maintenance activities. 6. Do not use this filtration system for anything other than the intended use. The use of attachments not approved, recommended or sold by the manufacturer / distributor may cause an unsafe condition. 7. Intended for indoor use. Do not install this filtration system where it will be exposed to the weather. Do not store this filtration system where it will be exposed to temperatures below freezing unless all the water has been drained from it and the water supply has been disconnected. 8. Read and observe all the important notices and warnings on the water filtration system. 9. If an extension cord is necessary, a cord with a proper rating should be used. A cord rated for less Amperes or Watts than the filtration system rating may over heat. Care should be taken to arrange the cord so that it will not be tripped over or accidentally pulled from the outlet. 2 Aqua Treatment Service, Inc
5 Function / Description ATS bag filter housings are intended to be installed in pipeline systems to remove unwanted solids from fluids. All ATS filter systems are designed to withstand rated pressures. Single bag housings should be installed only in systems where the flow can be interrupted in order to change the filter bags. Duplexed housing allows bag change without shutting down the flow. FEATURES: Stainless Steel 304 SS or 316 SS Swing Bolt Lid Closure Adjustable SS Legs 2 FNPT, side inlet and bottom outlet Buna O-Rings Schedule 80 PVC Piping - NPT 1/4 NPT Gauge Ports (clean and dirty sides) 1/4 NPT Vent in Head with 1/2 NPT bottom drain 1/8 Perf. SS Basket 150 PSI rated design Optional Goerge Fischer Auto Shut-off Valves Aqua Treatment Service, Inc
6 Installation NOTICE: Please remove all shipping and crating materials carefully. Be sure to remove the plugs from the inlet and outlet opening. Dispose of all crating materials safely. Pre-Installation Check List Water Pressure If the water pressure is over 100 psi, a pressure reducing valve must be installed before the equipment and set at 85 psi Electrical A continuous supply of 110 to 120 volt - 60 hertz current should be located at installation site of the equipment. A drain, must be available within 20 feet of the equipment. Location of the equipment must be where it is not subject to freezing, direct sunlight or room Temperature over 120 F. Installation 1. All plumbing must conform to local codes 2. Location Selection If it is likely that supplementary water treatment equipment will be required, make certain adequate additional space is available. Do not install any equipment closer to a water boiler than a total run of 10 feet of piping between the outlet of the equipment and the inlet to the any hot water. 3. Water Line Connection Close main water supply valve. Open to relieve water pressure and drain system. Set the equipment into installation position. Assess the installation (i.e. type of pipe, size of lines, etc.) and obtain necessary plumbing fittings for installation. Use Teflon tape on all threaded connections and avoid over tightening. WARNING: If your piping system is subject to impulse pressure resulting in a water hammer condition, a surge tank or other means must be provided to remove this condition. 4. Flanged Connection Flange bolts should be tight enough to slightly compress the gasket and make a good seal, without distorting or putting excessive stress on the flanges. Suitable washers should be used between the bolt head and flange and nut and flange. Nuts and 5/8 diameter bolts should be metal, well lubricated and used with soft rubber gaskets. Bolts should be tightened in alternating sequence to a final torque of foot pounds. 5. Electrical Connection All electrical supplies should be installed and checked by a qualified electrical contractor and follow all local codes. (See wiring diagram on page for details) 6. Drain Connection Run drain from system to open floor drain, making sure not to hard connect the line to the floor drain. 7. Bag Filter Installation Filter housings are not delivered with the bags installed. Please follow these installation steps compleatly. 1. Open cover and remove the bag hold down ring. 2. If opening the housing for the first time, remove the restraining basket and clean the inside of the housing to remove any shipping dust or packing debris. 3. Inspect all O-Rings, lubricat with compatible lubricant. 4. Place the restainer basket (if not already installed) into the filter housing. 5. Insert the filter bag into the restainer basket, after first removing the label from the bag. 6. Be crtain that the filter bag is pushed to the bottom of the basket and that the collar of the filter bag is pushed onto the rim of the restrainer basket. 7. Replace the bag hold down ring into the housing. Making sure it is on top of the filter bag collar. 8. Inspect the sealing surface and cover O-Ring to make sure they are clean and free of damage. 9. Close and seal cover, making sure not to over tighten the cover bolts. 8. Startup Prior to turning the water on, please check the following!! 1. Swing Bolts are secure and do not exceed recommend torque. 2. Electical conection is made and protected. 3. Bag filters are properly installed and all air purged from system. 4. Inlet and outlet flanges are securely fastened. 5. Slowly turn on water (making sure to check for leaks). WARNING: Always make sure that flow has been switched to alternate bag filter before performing any maintenance. 4 Aqua Treatment Service, Inc
7 Installation Diagram Skids are designed to allow water to enter from either side that your initial water supply is on. The outlet is also designed to go to either side, depending on which side your secondary filtration or disinfection system is on (i.e. Ultraviolet Disinfection System). Control Panel Inlet Pipe Outlet Pipe Filter Housing A Filter Housing B Inlet Pipe Inlet Pipe Outlet Pipe Housing Drain Lines Outlet Pipe Front View Inlet Pipe Inlet Pipe Outlet Pipe Outlet Pipe Back View Aqua Treatment Service, Inc
8 Maintenance Once the desired service flow has been established, the filter will operate efficiently until filter beg is dirty. With the standard filter basket, no more then 20 PSI Differential Pressure through the filter should be attained. Operating the filter unit with a high differential, may cause the filter bags to rupture and/or cause damage to the filter system or downstream equipment. o. Open the inlet valve (1/4 turn) to the filter housing. p. Allow water to slowly fill the Filter Housing there by letting the air escape and the Filter Housing to repressurize. Once full, close inlet water valve and pressure relief valve. To prevent excessive pressure loss, a differential pressure switch is installed and wired to the Control Panel. When this switch exceed 20 PSI an alarm is trigere in the Control Panel. This notifies the operator to know that maintenance is required. Steps for ag Replacement: 1. Determan which ag needs to be changed, via the indicator light on the Control Panel. 2. Pressing the button on the Control Panel will silance the alarm, however this will not turn off the indicater light. 3. To replace the Bag Filter you must first change which Filter is in operation. To do this you must follow these step. a. Open the inlet valve to the non-dirty filter housing. b. Open the outlet valve to the non-dirty filter housing. c. Close the inlet valve to the dirty filter housing. d. Close the outlet valve to the dirty filter housing. e. Open the drain line on the dirty filter housing. This will relieve the pressure and allow the differential switch to reset and turn off the indicator light. f. Loosen the swing bolts and remove the lid. g. Remove the Stainless Steel compression Spring (BFS-2) h. Remove Bag Filter i. Remove Stainless Steel Basket and clean. Once cleaned place the basket back into Filter Housing. j. Install NEW Bag Filter. k. Place Stainless Steel Spring back into Filter Housing. l. Clean and lubricate the O-Ring. m. Place the lid back in position and hand tighten Swing Bolts. n. With the drain closed, open the pressure releaf valve attop Filter Housing. 6 Aqua Treatment Service, Inc
9 Maintenance CAUTION: ALWAYS make sure the water is turned off to Bag Filter Housing and pressure is released before opening to replace Bag Filter or clean Stainless Steel Basket. Stainless Steel Spring Inlet Bag Filter The Stainless Steel Basket restes evenly on a ledge in the housing with the Bag Filter placed inside of it and is held in place with the Stainless Steel Spring. Stainless Steel Basket Drain Outlet Aqua Treatment Service, Inc
10 Control Panels Alarm Indicater Light Indicater Light Pressure Differential Guage Alarm Shutoff Pressure Differential Guage NOTE: Indicater Light will not go out when Alarm is Silenced. It will not go out untill pressure has been released in that Filter. 8 Aqua Treatment Service, Inc
11 Control Panel Wiring Diagram Aqua Treatment Service, Inc
12 Replacement Parts PARTS Item # Description Control Box 180 GPM Shelco Housing BFS-2-SB-2FNPT 350 GPM Shelco Housing BFS-2-SB-3FNPT Manual Ball Valve Automatic Ball Valve Stainless Steel Spring 180 GPM 8704-S Stainless Steel Spring 350 GPM N/A Stainless Steel Basket 180 GPM 3702-S Stainless Steel Basket 350 GPM FSP-2-RB Polypropolyne Bag Filter BPG Micron BPG SSH BPG-5-2-SSH BPG-10-2-SSH BPG-25-2-SSH BPG-50-2-SSH BPG SSH BPG SSH BPG SSH BPG SSH 10 Aqua Treatment Service, Inc
13 Parts Breakdown - Unit DFA Series 1.Control Box 2. Bag Filter Housing Front View 4. Automatic Ball Valve Back View 2. Bag Filter Housing 11 Aqua Treatment Service, Inc
14 Specifications DFM-2F & x 44 x lbs. DFM-3F & x 44 x lbs. DFM-3F & x 44 x lbs. DFA-2F & x 44 x lbs. DFA-3F & x 44 x lbs. DFA-3F & x 44 x lbs. Maximum Working Pressure psi at 70º F Maximum Working Temperature º F Body Only Maximum Flow GPM Without Bag Standered Ball Valve Optional Auto Ball Valve 12 Aqua Treatment Service, Inc
15 Dimensions DFM-3F-180 NOTE: Dimensions will very slightly with other models and pipe sizes used. CONTROL PANEL FILTER HOUSING A FILTER HOUSING B FILTER INLET VALVE 03 FILTER INLET VALVE FLANGE (INLET) 04 FLANGE (OUTLET) 04 FLANGE (OUTLET) FLANGE (INLET) Aqua Treatment Service, Inc
16 Troubleshooting Troubleshooting Symptom Cause Correction Low Pressure Clogged Filter Change Filter Alarm Clogged uzzer Press Silence Alarm button, change filter Leaky gasket Insufficient seal Remove gasket, silicone and reinstal No water flow Valve shut Check inlet and outlet ball valves Indicator lights off Interruption to power supply Call electrician Leak at Ball valve Insufficient seal with union ball valve Silicone O ring, tighten ball valve Leaky inlet or outlet connection Insufficient gasket seal at flange Replace gasket, tighten bolts 14 Aqua Treatment Service, Inc
17 Warranty REV. March, 2008 MANUFACTURER S LIMITED WARRANTY In accordance with the Manufacturer s warranty, and subject to the conditions hereinafter set forth, ATS will repair or replace to the original user or consumer, equipment, parts or components found to be defective in manufacturing or workmanship. WARRANTY PERIODS: Bag Filter Housing Electrical Components 1 yr. 1 yr. WARRANTIES NOT APPLICABLE: To defects or malfunctions resulting from failure to properly install, operate or maintain the unit in accordance with printed instructions; failure to use ATS authorized replacement parts, to failures resulting from shipment or handling, abuse, accident, negligence, freezing, fire or heat, direct exposure to weather or sunlight, water temperatures and pressures exceeding specifications, flooding or other acts of God not considered normal operating condition; to normal maintenance services and the parts used in connection with such service; to units which are not installed in accordance with applicable local codes, ordinances and good trade practices; if the unit is moved from its original installation location; or if unit is used for purposes other than for what it was designed and manufactured. LABOR COSTS, LIABILITY: Aqua Treatment Service, Inc., shall IN NO EVENT be responsible or liable for the cost of field labor or other charges incurred by any customer in installing, removing and/or reaffixing any ATS, part or component thereof, or be liable for any injury, loss or damage, direct or indirect, special or consequential, arising out of the use of, misuse, or the inability to use such product. Before use, Distributor, Dealer or User shall determine the suitability of the product for his/her intended purposes, and shall assume all risk and liability in connection therewith. RETURNS: A RETURN MERCHANDISE AUTHORIZATION NUMBER (RMA #) is required on ALL RETURNS. Contact ATS to obtain this number. The RMA # MUST be clearly written on the outside of the package. Address shipments to the Return Department ATS, 194 Hempt Road, Mechanicsburg, PA, 17050, and freight prepaid. All returns should be accompanied with a written description of mode or reason of failure. The customer must order ATS replacement parts if required as a standard purchase until the defective part is received and evaluated by the factory. ATS will inspect, test, and determine the cause of defective components or parts. ATS at its sole discretion will make necessary repairs to or replace components. ATS will determine the extent of the warranty coverage and the proper warranty credit to be applied. The return freight will be credited to the customer for warranty repairs or replacements. For your warranty protection, the warranty card must be completed and returned to ATS within 10 days of installation. In the absence of other suitable proof of installation date, the effective date of this warranty will be based on the date of manufacture plus 30 days. This warranty gives you specific legal rights and you may also have other rights, which vary, from state to state. Aqua Treatment Service, Inc
INSTALLATION, OPERATION AND MAINTENANCE MANUAL
PAGE: 1 of 6 INSTALLATION, OPERATION AND MAINTENANCE MANUAL ROSEDALE PRODUCTS, INC. DUPLEX MODEL 4 150 PSIG RATED FILTER UNIT Table of Contents I. Installation.......................................................................
More informationINSTALLATION, OPERATION AND MAINTENANCE MANUAL
PAGE: 1 of 6 INSTALLATION, OPERATION AND MAINTENANCE MANUAL ROSEDALE PRODUCTS, INC. MODEL LCO-8 125 PSIG RATED FILTER UNIT MODEL LCO-8 Table of Contents I. Installation...............................................................
More informationINSTALLATION, OPERATION AND MAINTENANCE MANUAL
PAGE: 1 of 6 INSTALLATION, OPERATION AND MAINTENANCE MANUAL ROSEDALE PRODUCTS, INC. MODEL 4 200 PSIG RATED FILTER UNIT Table of Contents I. INSTALLATION.................................................................
More informationINSTALLATION, OPERATION AND MAINTENANCE MANUAL
PAGE: 1 of 8 INSTALLATION, OPERATION AND MAINTENANCE MANUAL ROSEDALE PRODUCTS, INC. MODEL 6 BAG/CARTRIDGE CONVERTIBLE 150/300 PSIG RATED FILTER UNIT Table of Contents I. Installation...............................................................
More informationInstallation, Operation & Service Manual. PPL Bag Filter Housings. Table of Contents Page No. Eaton Filtration, LLC
Installation, Operation & Service Manual PPL Bag Filter Housings Eaton Filtration, LLC 900 Fairmount Avenue, Elizabeth, NJ 07207 Read all instructions before installation or operation of equipment. Failure
More informationINSTALLATION, OPERATION AND MAINTENANCE MANUAL
PAGE: 1 of 8 INSTALLATION, OPERATION AND MAINTENANCE MANUAL ROSEDALE PRODUCTS, INC. GIARDIA FILTER SYSTEM NSF/MODEL 8 MULTIPLEX 150 PSIG RATED FILTER UNIT Table of Contents I. Installation...............................................................
More informationSTOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL
CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL MODEL #VP05, VP10 C US NSF/ANSI 372 255405 For loose, missing or damaged parts, or if the unit does not seem to be operating properly, please call before returning
More informationHALLMARK INDUSTRIES INC
Performance Part No. HP. CONVERTIBLE JET PUMP USER S MANUAL GPH of Water @ Total Discharge Pressure of 40 psi Max. Pressure Max suction (shallow well) Max Suction (deep well) Max GPM (@0 head) Max Discharge
More informationINSTALLATION, OPERATION AND MAINTENANCE MANUAL
PAGE: 1 of 6 INSTALLATION, OPERATION AND MAINTENANCE MANUAL ROSEDALE PRODUCTS, INC. MODEL 4 SANITARY 125 PSIG RATED FILTER UNIT Table of Contents I. INSTALLATION.................................................................
More informationInstallation, Operation and Maintenance Manual
IOM-HS-QTColdBevMax Installation, Operation and Maintenance Manual QT TM Cold Bev Max TM Models: QTCLDBMX-1S-.5M, QTCLDBMX-2S-.5M, QTCLDBMX-3S-.5M, QTCLDBMX-4S-.5M, QTCLDBMX-5S-.5M Tested and Certified
More informationAqua Ultraviolet Sunami Series Pumps 1/3HP, 3/4HP, 3HP, 4HP, 5HP
TM 42371 Avenida Alvarado Temecula, CA 92590 TOLL FREE (800) 454-2725 TEL (951) 296-3480 FAX (951) 296-3490 www.aquauv.com Aqua Ultraviolet Sunami Series Pumps 1/3HP, 3/4HP, 3HP, 4HP, 5HP Sunami Warranty
More informationAPCO ASR-400/450 SEWAGE AIR RELEASE VALVES
APCO ASR-400/450 SEWAGE AIR RELEASE VALVES Instruction D12005 December 2012 Instructions These instructions provide installation, operation and maintenance information for the APCO ASR- 400/450 Sewage
More informationGARDEN HOSE UTILITY PUMP
GARDEN HOSE UTILITY PUMP MODEL #HPP360, HPP12V, 473707 MODEL #HPP360, 473707 MODEL #HPP12V ATTACH YOUR RECEIPT HERE Purchase Date SAFETY INFORMATION Please read and understand this entire manual before
More informationInstallation, Operation and Maintenance Manual
IOM-HS-QTCubeMax Installation, Operation and Maintenance Manual QT TM Cube Max TM Models: QTCBMX-1S-1M, QTCBMX-2S-1M, QTCBMX-3S-1M, QTCBMX-4S-1M, QTCBMX-1L-1M, QTCBMX-2L-1M, QTCBMX-3L-1M, QTCBMX-4L-1M,
More informationDual/Triple Manifold Water Filtration Systems Instruction Manual
3M TM Water Filtration Products Dual/Triple Manifold Water Filtration Systems Instruction Manual High Flow Series Water Filtration Systems Installer: Please leave this manual with owner/operator. 3M Water
More informationPressurized Bead Filters
Pressurized Bead Filters Installation Instructions Table of Contents Safety Information Installation Assembly Start Up Maintenance Troubleshooting Warranty Safety Information: 1. Installation should be
More informationInstallation & Maintenance of the Fresh-Aire UV Airborne Duct System for Commercial HVAC Systems. Parts Included. Optional Parts
Installation & Maintenance of the Fresh-Aire UV Airborne Duct System for Commercial HVAC Systems The Fresh-Aire UV Airborne Duct System is designed for installation into commercial HVAC system ducts for
More informationSEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14
SEWAGE PUMP Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #1261-0001 Español p. 14 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems, missing parts?
More informationPRE-PLUMBED SEWAGE SYSTEM
PRE-PLUMBED SEWAGE SYSTEM Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #1910-0009 Español p. 13 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems,
More informationTBM Series 3-Way Ball Valve
www.simtechusa.com TBM Series 3-Way Ball Valve Operating, Installation, & Maintenance Manual Corrosion Resistant Fluid and Air Handling Systems. Dated 06-26-13 TBM Series Ball Valves SIMTECHRECOMMENDSREADINGTHEFOLLOWINGINFORMATIONPRIORTOINSTALLINGANDUSING
More informationPEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.
PEDESTAL SUMP PUMP Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #1084-0001 Español p. 11 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems, missing
More informationVal-Matic Air / Oil Hydraulic Panel Pump Control System. Operation, Maintenance and Installation Manual
Manual No. 5AOP-OM1-2 Val-Matic Air / Oil Hydraulic Panel Pump Control System Operation, Maintenance and Installation Manual INTRODUCTION... 1 RECEIVING AND STORAGE... 1 DESCRIPTION OF OPERATION... 1 INSTALLATION...
More informationOwner s Manual WARNING
Filter Housing Models: AWP20C-V, AWP30C-V, AWP32B-V. Overview: Owner s Manual VIQUA offers a variety of housing sizes and styles in durable, molded polymer that defies rust and corrosion, and ensures a
More informationSUBMERSIBLE SUMP PUMPS
SUBMERSIBLE SUMP PUMPS Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODELS #1073-0001, 1075-0001 Español p. 9 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems,
More informationSUBMERSIBLE SUMP PUMPS
SUBMERSIBLE SUMP PUMPS Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #1099-0001 Español p. 11 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems, missing
More informationS33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN
S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN AUTOMATIC S33A1 & S33A1C WARNING risk of electric shock.
More informationKompensator External Low Voltage Heating Cable System
External Low Voltage Heating Cable System LOW VOLTAGE Installation Instructions General Information Kit Contents Qty Description 1 heating cable at pre-determined length Table of Contents General Information........................
More informationAPCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES
APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES Instruction D12043 June 2016 DeZURIK Instructions These instructions provide installation, operation and maintenance information for APCO CRF-100A Rubber
More informationHAYWARD FLOW CONTROL TBH SERIES TRUE UNION BALL VALVE INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
HAYWARD FLOW CONTROL TBH SERIES TRUE UNION BALL VALVE INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Pg. 1 of 10 PLEASE READ THE FOLLOWING INFORMATION PRIOR TO INSTALLING AND USING HAYWARD TBH SERIES
More informationOwner s Manual GLASSLINED PUMP TANK
Owner s Manual GLASSLINED PUMP TANK ANSI/NSF 61 Annex G Thank You for purchasing a pump tank. Properly installed and maintained, it should give you years of trouble free service. If you should decide that
More informationGRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13
GRINDER PUMP Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #2701-0005 Español p. 13 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems, missing parts?
More informationQUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE
QUICK START GUIDE OWNER S MANUAL SAFETY, INSTALLATION, OPERATION & PARTS AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL 877-278-2797 DO NOT RETURN TO STORE! WARNING This equipment must be installed
More information8000 / 10,000 / 12,000
INSTALLATION AND SERVICE MANUAL Please fill in for future reference: MODEL: SERIAL NUMBER: DATE PURCHASED: EUROXXXXXX-SW S/N: XXXX-XXXXXX WARNING: PLEASE READ COMPLETELY BEFORE YOU INSTALL OR OPERATE YOUR
More informationHP190SL Series Slimline Radon Fans
Installation and Operation Manual Item #: 412843 Rev Date: 070113 HP190SL Series Slimline Radon Fans United States 10048 Industrial Blvd., Lenexa, KS, 66215 Tel.: 800.747.1762 Fax: 800.487.9915 Canada
More information8 Light Controller. Instruction Manual. With Light Timer 240 Volts. Product # INNOVATING SINCE 1995
8 Light Controller With Light Timer 240 Volts Product #703008 Instruction Manual INNOVATING SINCE 1995 1 www.titancontrols.net 8 Light Controller This manual covers the following: Warnings & Cautions 8
More informationREAD THIS MANUAL CAREFULLY BEFORE USING THE PUMP
OWNER S MANUAL Pond Pump READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP Important Notice: This manual contains important information about the installation, operation and safe use of this product. This
More informationMaintenance Manual. Automated Fuel Maintenance System FTI-5A SINGLE TANK FUEL TECHNOLOGIES INTERNATIONAL
Maintenance Manual Automated Fuel Maintenance System FTI-5A SINGLE TANK FUEL TECHNOLOGIES INTERNATIONAL 05/01/2016 Rev A Fuel Technologies FTI-5A Single Tank Maintenance Section FTI - Fuel Maintenance
More informationPARTS AND INSTALLATION MANUAL
PSP-3240 POLYPROPYLENE SELF-PRIMING 2 CENTRIFUGAL PUMP PARTS AND INSTALLATION MANUAL PSP-3240 Shown with GX-160 Honda CDS-JOHN BLUE COMPANY DIVISION OF ADVANCED SYSTEMS TECHNOLOGY, INC. 165 Electronics
More informationPowerFLO 7800 Series 12 Volt DC Motor-Driven Diaphragm Pumps
Installation Operation Repair Parts PowerFLO 7800 Series 12 Volt DC Motor-Driven Diaphragm Pumps Specifications Motor Type: 12 VDC, permanent magnet, totally enclosed, non-ventilated Leads: 14 AWG, 12
More informationScale Feeder Manifold Water Filtration System Instruction Manual
3M TM Water Filtration Products Scale Feeder Manifold Water Filtration System Instruction Manual For SF1XX High Flow Series Water Filtration Systems Installer: Please leave this manual with owner/operator.
More informationPVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables
PVI 1800/PVI 2500 WARRANTY MANUAL Residential/Commercial Grid-Tied Photovoltaic Inverter 2009, Solectria Renewables Subject to Change REV 10.09 1 Product Warranty & RMA Policy 1.1 Warranty Policy The Solectria
More informationGeneral Installation Instructions for Valves and Gates
General Installation Instructions for Valves and Gates Thank you for your purchase of a Lorenz valve. We appreciate your business! Please read this installation manual and follow recommended safety precautions.
More informationInstallation Manual DIAPHRAGM WELL TANK
Installation Manual DIAPHRAGM WELL TANK IN-LINE SERIES: 2-5 & 7 GALLON VERTICAL SERIES: 14-20-25-32-36-52-65-86-96-119 GALLON HORIZONTAL SERIES: 7-14 & 20 GALLON NO LEAD NO LEAD: The weighted average of
More informationRight Weigh. Load Scales. Right Weigh Digital Load Scale. Model 201-EDG-01(B) Installation and Operation Manual
Right Weigh Load Scales Right Weigh Digital Load Scale Model 201-EDG-01(B) Installation and Operation Manual Please read carefully before installation Right Weigh Load Scales Table of Contents Model 201-EDG-01
More informationInstallation, Operation, Repair and Parts Manual
Self-Priming Adaptor Form L-1516 (3-08) Installation, Operation, Repair and Parts Manual Description Self-priming adaptor (SPA) is a low pressure tank that provides air separation from the liquid being
More informationMaintenance Manual WITH ONE SUBMERSIBLE PUMP. Automated Fuel Maintenance System FTI-5A FUEL TECHNOLOGIES INTERNATIONAL LLC
Maintenance Manual WITH ONE SUBMERSIBLE PUMP Automated Fuel Maintenance System FTI-5A FUEL TECHNOLOGIES INTERNATIONAL LLC Replacement Manuals Available on Website: www.fueltechnologiesinternational.com
More informationStormPro BA Series Sump Pump
Page 1 of 8 Marks & Meanings DANGER: Keep the pump equipment out of the reach of children! Warns that the failure to follow the directions given could cause serious risk to individuals or objects. WARNING:
More information4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause
4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL BEFORE INSTALLING PUMP, BE SURE TO READ THIS OWNER S MANUAL CAREFULLY. CAUTION Fill pump with water before starting or pump will be damaged. The motor on
More informationIMPORTANT SAFETY INSTRUCTIONS
OWNER S MANUAL FLO-MASTER XP2 SERIES PUMPS IMPORTANT SAFETY INSTRUCTIONS When installing and using this electrical equipment, basic safety precautions should always be followed, including the following:
More informationQUALITY MISTING PUMPS
TOTALLY ENCLOSED DIRECT DRIVE 60030KH, 60031KH, 60050KH, 60051KH 60100KH, 60101KH, 60150KH, 60151KH MISTING PUMP MANUAL INCLUDING: SPECIFICATION DATA, GENERAL SAFETY PRECAUTIONS, OPERATION, INSTALLATION,
More informationInstallation / Operation Manual
Installation / Operation Manual Installation Requirements Pressure Range: 10-150 psi Temperature Range: 40-120 F Max Service Flow Rate: 25gpm NOTE: Position filter on a level surface. Filter must be installed
More informationAUTOMATIC SUBMERSIBLE UTILITY PUMP
AUTOMATIC SUBMERSIBLE UTILITY PUMP Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #1043-0006 Español p. 9 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems,
More informationMatala. VersiFlow Series. Instruction and Maintenance Manual
VersiFlow Series High Flow Multi-Purpose "Versatile " Pump V-3200 1/5HP 150W / Discharge 2 V-3900 1/3HP 250W / Discharge 2 V-4700 1/2HP 400W / Discharge 2 V-5600 1HP 750W / Discharge 2 Instruction and
More informationALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase
ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL AL- Model Number Date Code / Serial Number Date of Purchase LIMITED WARRANTY ALITA warrants to the original retail consumer purchaser ( Customer ) that
More informationDual Flow Manifold Systems Instruction Manual
3M TM Water Filtration Products Dual Flow Manifold Systems Instruction Manual For DF1XX and DF2XX High Flow Series manifolds and water filtration systems Installer: Please leave this manual with owner/operator.
More informationSF Series Screen Filter OWNER S MANUAL OPERATION AND INSTRUCTION GUIDE
THERMAL CARE SF Series Screen Filter OWNER S MANUAL OPERATION AND INSTRUCTION GUIDE Record in the space below the Serial # of your unit Serial # Serial # Stamped on Outlet Flange Flanged Outlet Disk Filter
More informationPremium Supply. Direct Push. Models PCK-3530-DP PCK DP PCK-530-DP. Operator s Manual and Installation Instructions
Direct Push Models PCK-3530-DP PCK-3530-2DP PCK-530-DP Operator s Manual and Installation Instructions Premium Supply 2038 West Interstate 30 866-934-0777 Proud members of: and June 20, 2018 Table of Contents
More informationNelsen Filtration Cartridge Systems
Nelsen Filtration Cartridge Systems NFS-HF Residential/Light Commercial Cartridge Tank System NFS-HF-PLUS Commercial Cartridge Tank System Installation & Maintenance Manual ! Important Dealer/Homeowner
More informationMaintenance Manual. Automated. Fuel Maintenance System FTI-5A. FUEL TECHNOLOGIES INTERNATIONAL LLC
Maintenance Manual Automated Fuel Maintenance System FTI-5A FUEL TECHNOLOGIES INTERNATIONAL LLC www.fueltechnologiesinternational.com 03/01/2011 - Fuel Technologies FTI-5A Maintenance Section FTI - Fuel
More informationINSTALLATION AND SERVICE INSTRUCTIONS AND REPAIR PARTS LIST FOR MODELS K4RP & K4VP SUBMERSIBLE SOLIDS-HANDLING SEWAGE PUMPS
471 US Hwy 250 East, Ashland, Ohio 44805 PH: 419-207-9400 FX: 419-207-8031 INSTALLATION AND SERVICE INSTRUCTIONS AND REPAIR PARTS LIST FOR MODELS K4RP & K4VP SUBMERSIBLE SOLIDS-HANDLING SEWAGE PUMPS 10/2014
More informationQUALITY MISTING PUMPS
DIRECT DRIVE TOTALLY ENCLOSED FAN COOLED 60200KH, 60201KH MISTING PUMP MANUAL INCLUDING: SPECIFICATION DATA, GENERAL SAFETY PRECAUTIONS, OPERATION, INSTALLATION, PARTS, MAINTENANCE & WARRANTY QUALITY MISTING
More informationME3H/ME3F SERIES. Automatic and manual models. Single phase power only 115 or 230 volt.
ME3H SUMP/EFFLUENT PUMP ME3F SUMP/EFFLUENT PUMP ME3H/ME3F SERIES SUBMERSIBLE SUMP AND EFFLUENT PUMPS INSTALLATION AND SERVICE MANUAL Automatic and manual models. Single phase power only 115 or 230 volt.
More informationSUBMERSIBLE MINI-PUMP
SUBMERSIBLE MINI-PUMP Model 41287 Set up And Operating Instructions Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may differ slightly from
More information1 2-Inch Station Outlet Valves
ADI 1089M Certified ISO 9001:2000 1 2-Inch Station Outlet Valves Non-Return Type INSTALLATION AND OPERATION INSTRUCTIONS Before Installing or Operating, Read and Comply with These Instructions Controls
More informationPRYCO, INC. P. O. BOX 108 Mechanicsburg, IL OPERATIONS AND MAINTENANCE MANUAL For PUMP SETS
PRYCO, INC. P. O. BOX 108 Mechanicsburg, IL 62545 Telephone: 217 / 364-4467 Fax: 217 / 364-4494 OPERATIONS AND MAINTENANCE MANUAL For PUMP SETS WHAT TO DO FIRST Upon receiving your new pump set system
More informationWastewater Combination Air Valve. Operation, Maintenance and Installation Manual
Manual No. WCAV-OM1-1 Wastewater Combination Air Valve Operation, Maintenance and Installation Manual INTRODUCTION... 2 RECEIVING AND STORAGE... 2 DESCRIPTION OF OPERATION... 2 INSTALLATION... 3 VALVE
More informationUsers Manual Certified Series Direct Drive Pump 1-7 LPM
Users Manual Certified Series Direct Drive Pump 1-7 LPM Safety, Operating, Installation, and Maintenance Instructions 600 S 56 th Street #9 Chandler, AZ 85226 Phone: 480-507-6478 Fax: 480-838-2232 www.fogco.com
More informationOwners Manual: - Pumps
Owners Manual: - Pumps GENERAL SAFETY RULES 1. The products mentioned in this manual are specially designed for the pre-filtering and re-circulation of water in swimming pools and spas. 2. They are designed
More informationOWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS
OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS IMPORTANT SAFETY INSTRUCTIONS When installing and using this electrical equipment, basic safety precautions should always be followed, including
More informationTALCO FIRE SYSTEMS. LSF Start-Up Instructions. 1) IMPORTANT: Inspect the unit for damage. Report any damage to the freight carrier immediately.
LSF Start-Up Instructions 1) IMPORTANT: Inspect the unit for damage. Report any damage to the freight carrier immediately. 2) PRE-START-UP: Be sure there is water in the pump. Bleed air at all high points
More informationExterior Digital Load Scale 201-EDG-01(B) Installation and Operation Manual Please read carefully before installation
Exterior Digital Load Scale 201-EDG-01(B) Installation and Operation Manual Please read carefully before installation 2 Exterior Digital Load Scale 201-EDG-01(B) Table of Contents Specifications & Overview
More informationBenron Equipment & supply, Inc.
Benron Equipment & supply, Inc. Service Manual G5 Part Number 6-00A. and 6-00M Edition 0/008 Ez-Tex G5 Operational Instructions. Before attempting to use the G5 check material manufacturer for mixing and
More informationHANDLING MANUAL FILTERS & PRESSURE TANKS
HANDLING MANUAL FILTERS & Basic Operation / Maintenance / Warranty INDEX A - Basic Operations A.1- Lifting and Unload...3 - Horizontal Tanks and Filters...3 - Vertical Tanks and Filters...4 - Important
More informationBypass / Filter Feeders Operations & Maintenance Manual
Bypass / Filter Feeders Operations & Maintenance Manual Record Your Model, Serial Number and Other Information on the back of this document. Manufacturing: Bypass & Filter Feeders, Glycol Feed Packages,
More informationTHE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY THE COMPANY WITH RESPECT TO THE PRODUCT.
Series 909 Reduced Pressure Zone Backflow Preventers Sizes: 3 /4" 2" (20 50mm) Installation Service Repair Kits Maintenance No. 1 1 2" shown Patent Number 4,241,752 IMPORTANT: Inquire with governing authorities
More informationA Member of the. Integrated Metering Technologies
I n s t a l l a t i o n M a n u a l A Member of the Integrated Metering Technologies 1.0 General and safety Do not install, operate or maintain this flow meter without reading, understanding and followingthe
More informationThe Da-Lite Difference.
The Da-Lite Difference. Instruction Book for Boardroom Electrol DA-LITE SCREEN COMPANY, INC. 3100 North Detroit Street Post Office Box 137 Warsaw, Indiana 46581-0137 Phone: 574-267-8101 800-622-3737 Fax:
More informationFIXED DEPTH INSERTION METER INSTRUCTIONS
UNPACKING Please open and inspect your package upon receipt. Your package was packed with great care and all the necessary packing materials to arrive to you undamaged. If you do find an item that is broken
More informationWastewater Air Release Valve Models 48A, 49A
Manual No. WWAR-OM1-2 Wastewater Air Release Valve Models 48A, 49A Operation, Maintenance and Installation Manual INTRODUCTION... 1 RECEIVING AND STORAGE... 1 DESCRIPTION OF OPERATION... 1 INSTALLATION...
More informationOWNER S MANUAL Spa & Jetted Bathtub Pump
OWNER S MANUAL Spa & Jetted Bathtub Pump READ THIS MANUAL CAREFULLY BEFORE USING THE SPECK PUMP Important Notice: This manual contains important information about the installation, operation and safe use
More informationProFlo FatBoy
The Standard For Professional Grade Diaphragm Pumps. ProFlo 3300 5500 FatBoy Operational and Installation Guidelines, Repair & Parts Contents 3300 5500 Fatboy Operational and Installation Guidelines...2
More informationSUPERPLUS WATER FILTRATION SYSTEM
SUPERPLUS WATER FILTRATION SYSTEM For Model #: SP20-1 INSTRUCTIONS/ASSEMBLY USE AND CARE MANUAL (Important: Read this manual thoroughly before install) TABLE OF CONTENTS 2 3 4 6 8 9 10 11 12 General Notes
More informationValue Super Filter Max Installation Manual
Value Super Filter Max Installation Manual Barrie, Ontario, Canada, L4N 4Y8 www.excaliburwater.com EXCALIBUR VALUE SUPER FILTER MAX INSTALLATION MANUAL INSTALLATION PROCEDURES: The Value Super Filter Max
More informationHQUA. UV Water Sterilizer Instruction Manual. Contents
UV Water Sterilizer Instruction Manual Contents Section 1 Safety Information 2-3 Section 2 General Information.4-7 Section 3 Maintenance.7-9 Section 4 Troubleshooting.10 Section 5 After-Sales Service...10
More informationCSA products for waste water. Anti water hammer combination air valve. Mod. SCF-RFP
CSA products for waste water Anti water hammer combination air valve Mod. SCF-RFP Instructions These instructions provide installation, operation and maintenance information for CSA Mod. SCF-RFP series
More informationgamma uv Aquarium Ultraviolet Sterilizers
gamma uv Aquarium Ultraviolet Sterilizers Instructions for Models #1400 8w, 1401 15w, 1402 25w Important Safety Instructions... Page 2 Installation... Page 3 8/15/25 watt Alternate Diagrams... Page 5 25
More informationPENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
Before installation, these instructions must be read carefully and understood. PRODUCT WARRANTY Emerson warrants its Penberthy products as designed and manufactured to be free of defects in the material
More informationInstallation and Service Manual for SRC25, SRC252, SRC50, SRC502, SRC75, SRC752
Rocking Piston Compressors Installation and Service Manual for SRC25, SRC252, SRC50, SRC502, SRC75, SRC752 Thank you for purchasing the Stratus SRC series rocking piston compressor. This instruction manual
More informationLaboratory Series. Ultraviolet Ozone Destruct System Installation, Operation and Maintenance Manual. One Source for All Your UV Needs!
Laboratory Series Ultraviolet Ozone Destruct System Installation, Operation and Maintenance Manual KEEP THIS MANUAL ON HAND IT IS IMPORTANT THAT THOSE RESPONSIBLE FOR THE INSTALLATION OF THIS EQUIPMENT,
More informationFull Flow Drinking Water System Model: 3MFF100
Installation and Operating Instructions For Full Flow Drinking Water System Model: 3MFF100 System tested and Certified by NSF International against NSF/ANSI Standard 42 and 53 for the reduction of the
More informationFission. Nano-Protein Skimmer. Instructions for Model#8100
Fission Nano-Protein Skimmer Instructions for Model#8100 Warning and Safety Instructions... Page 2 Skimmer Assembly... Page 3 Skimmer Installation... Page 5 Skimmer Maintenance... Page 7 Warranty... Page
More informationHYDRAULIC POWER PACK
HYDRAULIC POWER PACK OPERATION & MAINTENANCE MANUAL Model 34484 Copyright 2012 by All rights reserved. No part of this publication may be copied, reproduced or transmitted in any form whatsoever without
More informationPreSoak System (NonFoaming) DU PS1-HP DU PS6-HP
PreSoak System (NonFoaming) DU PS1-HP DU PS6-HP Serial Number: Owner s Manual #0786 040810 Installation Date: Please read and u n d e r s t a n d t h i s manual. Store in safe location for future reference.
More informationREAD THIS MANUAL CAREFULLY BEFORE USING THE PUMP
OWNER S MANUAL Swimming Pool Pump READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP Important Notice: This manual contains important information about the installation, operation and safe use of this product.
More informationStormPro BCV400 Sewage Ejector Pump
Page 1 of 8 Marks & Meanings DANGER: Keep the pump equipment out of the reach of children! Warns that the failure to follow the directions given could cause serious risk to individuals or objects. WARNING:
More informationInstallation and Operation Manual
Installation and Operation Manual * Read all installation instruction and warranty information prior to beginning installation * XeVision HID landing and taxi lights are for experimental aircraft only
More informationSeries 957, 957N, 957Z, 957RPDA, 957NRPDA, 957ZRPDA
Series 957, 957N, 957Z, 957RPDA, 957NRPDA, 957ZRPDA Reduced Pressure Zone Assemblies Reduced Pressure Detector Assemblies Sizes: 2 1 2" 10" (65 250mm) Installation Service Repair Kits Maintenance RP/IS-957/957RPDA
More informationPVI 60KW, PVI 82KW, PVI 95KW
PVI 60KW PVI 82KW PVI 95KW WARRANTY MANUAL Commercial, Grid-Tied Photovoltaic Inverters 2008, Solectria Renewables LLC Subject to Change DOC-020099 rev 024 1 1 Product Warranty & RMA Policy Warranty Policy
More informationVal-Matic 1-4 Combination Air Valve (Single Housing Type)
Manual No. ARCO-OM1-3 Val-Matic 1-4 Combination Air Valve (Single Housing Type) Operation, Maintenance and Installation Manual INTRODUCTION... 1 RECEIVING AND STORAGE... 1 DESCRIPTION OF OPERATION... 1
More informationCSA products for waste water. Combination air valve. Mod. SCF 2
CSA products for waste water Combination air valve Mod. SCF 2 Instructions These instructions provide installation, operation and maintenance information for CSA Mod. SCF-2 series waste water air valve.
More information