RHM 80 - Coriolis Mass Flowmeter for large flow applications optional heavy duty version

Similar documents
RHM Coriolis Mass Flowmeter for high Flow Applications

RHM The world s largest Coriolis Mass Flowmeter for flow rates up to kg/min

RHM 60. Coriolis Mass Flowmeter for Medium Flow also Suited for High Pressure Applications. Applications. Advantages. Features

RHM 12 - Standard 1 inch Coriolis Mass Flowmeter

RHM 04 - Universal Coriolis Mass Flowmeter with particular Fast Response

Ultimate Low Flow Coriolis Mass Flowmeter

RHM 04. Universal Coriolis Mass Flowmeter with particular Fast Response. Applications. Features. Advantages

RHM 03. Flexible Coriolis Mass Flowmeter for low flow measurements. Applications. Features. Advantages

RHM 06. One of the Most Popular Rheonik Mass Flowmeter Serving Thousands of Worldwide Applications. Applications. Advantages.

RHM 08. One of the most popular Rheonik Mass Flowmeter serving thousands of worldwide applications. Applications. Advantages.

RHM 015. Ultimate Low Flow Coriolis Mass Flowmeter. Applications. Features. Advantages

Coriolis Mass Flowmeter for low flow measurements

RHM 03 a1 - (low stress in welds and increased wall thickness against abrasion) RHM bar APPLICATIONS. Batching Dosing. Injections Filling

RHM40. Coriolis Mass Flow Meter for Demanding Applications. Features. Applications. Benefits

RHM30. Coriolis Mass Flow Meter for Plant and Loading Flows. Features. Applications. Benefits

RHM015. Ultimate Performance Coriolis Mass Flow Meter for Critical Ultra Low Flow Applications. Features. Applications. Benefits

RHM04. Compact Coriolis Flow Sensor With Enhanced Performance. Features. Applications. Benefits

RHM08. Versatile Coriolis Mass Flow Meter. Features. Applications. Benefits

RHM 015L/02L/03L/04L. Compact Low Flow Coriolis Flow Sensors

RHM 015L/02L/03L/04L. Compact Low Flow Coriolis Flow Sensors

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel

Rheonik Coriolis Mass Flow Meters

Micro Motion Model D and DL Coriolis Flow and Density Meters

Micro Motion F-Series Coriolis Flow and Density Meters

Flow Measurement SITRANS F M. Flow sensor MAG /85. Overview

SITRANS F flowmeters SITRANS F C

SITRANS F flowmeters SITRANS F C SITRANS F C MC2 4/169. Overview

LIQUID CONTROLS A Unit of IDEX Corporation

VersaFlow Coriolis 100 Mass Flow Sensor Specifications

OPTIMASS 3000 Technical Datasheet

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T

SITRANS F flowmeters SITRANS F C MASSFLO MASS MC1. 4/146 Siemens FI Overview

Micro Motion T-Series Straight-Tube Mass Flow and Density Meters. Product Data Sheet PS July 2001

Micro Motion ELITE High Capacity Coriolis Flow and Density Meters

OPTIMASS 2000 Technical Datasheet

Food & beverage. Oil & gas. Water & waste water

SITRANS F C. Flow sensor MC2 4/193. Overview

Product Data Sheet PS February Model D and DT. Mass Flow and Density Sensors.

VersaFlow Vortex 100 Vortex Flow Meter Specifications

Flowmeters. The Satam flowmeter range is used for the custody transfer measurement of liquid hydrocarbons, liquid gas and liquid chemicals.

Coriolis Flow Solutions for a Global Marketplace

OPTIGAS 4010C Technical Datasheet

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

Flow Measurement SITRANS F M. Flow sensor MAG 1100 F 4/57

KROHNE 10/ Optimass 70 & 71 Single Tube Coriolis Mass Flowmeters for the Pharmaceutical Industry

Metal tube variable area flowmeter for gases, liquids and steam

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

Coriolis Flow Solutions for a Global Marketplace

Flow Measurement SITRANS F C. Flow sensor MASS 2100 DI 3 to DI 40. 4/180 Siemens FI

OPTIGAS 4010C Technical Datasheet

KROHNE 10/ Optimass 70 & 71 Single Tube Coriolis Mass Flowmeters for the Chemical Industry

Armstrong In-Line and Insertion Vortex Flow Meters

Flow Measurement SITRANS F C

Coriolis Mass Flow Measuring System promass 64

Micro Motion F-Series Coriolis Flow and Density Meters

SITRANS F M. Flow sensor MAG 1100 F 3/59

Operating Instructions. VEGASWING 61, 63 with oscillator SW E60N (EX)

Micro Motion ELITE Coriolis Flow and Density Meters

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet

Micro Motion ELITE High Capacity Coriolis Flow and Density Meters

JUMO dtrans p02. Pressure transmitter. General application. Approvals/marks of conformity. Data Sheet Page 1/6. II 1/2G Ex ia IIC T6 Ga/Gb

Flow Measurement SITRANS F C

Micro Motion ELITE Mass Flow and Density Meters

Series Level-Trol Electronic Liquid Level Transmitters

SITRANS F C MASSFLO Practical examples of ordering. MASS2100 & MASS6000 IP67 Compact mounted

MASSMAX 1000 Series Straight twin tube Coriolis Mass Flowmeter

Thermowell for temperature sensors omnigrad M TW 13

Flow Measurement SITRANS F M

Magnetic-inductive flow meter for hazardous areas

HTM Series Helical Turbine Meters

Flow Measurement SITRANS F C

SITRANS F M flow sensors 711/A and 711/911E

Micro Motion Model CNG050 Compressed Natural Gas Flowmeters

KROHNE 10/ Optimass 70 & 71 Single Tube Coriolis Mass Flowmeters for Food & Beverage Processing

Micro Motion Model CNG050 Compressed Natural Gas Flowmeters

Level Probes multicap T DC 12 TE multicap T DC 11/16/21/26 TEN/TES

Micro Motion 7827 Digital Viscosity Meter

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Pneum. Buoyancy Transmitter with Torque Tube for Liquid Level, Interface and Density

Level Measurement Point level measurement - RF Capacitance switches

Level Limit Switch liquiphant FTL 365 / FTL 366

Absolute pressure gauge with diaphragm

Solenoid Valves Type 3963

Options guide. Electromagnetic flowmeters. M9xx

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

LCMass Series Mass Flow Sensor

Coriolis Flowmeters. Coriolis Flowmeters. KCM C-flow series Coriolis mass flowmeter

OPTISWITCH 4000/5000. Vibration level switches for liquids

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

Flow Measurement SITRANS F M. Flow sensor MAG 5100 W. 4/68 Siemens FI Overview

BETA SWITCHES FOR HAZARDOUS AREA

KDM ARMORED FLOW METER & SWITCH

Promass Q for the process industry

Indumax P CLS50. Technical Information. Highly resistant, inductive conductivity sensor for standard, hazardous and high-temperature applications

SITRANS FC. Flowmeter SITRANS FC410

Multivariable Vortex Flow Meter

THE EXPERT IN LEVEL AND FLOW

VORTEX FLOW METTER DVH. Despriction. Advantages of the DVH Vortex Flow Meter

Now available with MVD Technology! ELITE Mass Flow and Density Meters

Transcription:

RHM 80 - Coriolis Mass Flowmeter for large flow applications optional heavy duty version The RHM 80 can measure flow rates up to 480 t/hr with the patented Omega shape meter technology manufactured by rheonik, the mass flowmeter experts. APPLICATIONS Loading of boats, vessels, rail road tank wagons High temperatures and other challenging applications Highly viscous media (low pressure drop and excellent performance at low flow conditions) FEATURES As heavy duty version available (increased wall thickness of measuring pipes for additional safety - 160 bar) Flow Accuracy better than 0.2% Repeatability better than 0.05% Patented torsion swinger Customer adaptations possible for application optimized solutions Typical measuring ranges from 160 to 8000 kg/min EEx Approvals (i.e. ATEX, CSA,...) Custody Transfer Approvals (i.e. PTB, NMI,...) GENERAL The RHM 80 has been designed for medium flow rates and tough application conditions. Optional heavy duty measuring pipes make this meter suitable for for applications applications involving corrosive media at high high temperature. involving This unique design, which offers excellent performance and reliability, has created the most satisfied customers worlwide. Unlike other mass flowmeter manufacturers, Rheonik uses a patented torsion rod swinger with the Omega shape and support bars which results in high accuracy measurement, which is independent of pressure, even at very low flow velocities. The meter also has extremely good repeatability and high stability for critical applications. ADVANTAGES High flow rates for fast filling Patented torsion swinger design assures most stable and drift free measurement Increased signal to noise ration by torsion swinger Longest life time and increased safety (low stress in welds and increased wall thickness against abrasion) No moving parts, practically no maintenance RHM 80 Page 1 of 5 / 18 November 2005 - v5

PERFORMANCE RHM 80 Max Flow 8000 kg/min (17635 lb/min) 1) Standard Models Rates / turndown ratio in kg/min in lb/min error in % of reading nominal rate Qnom 5000 11025 0.20 0.2 * Qmax (5:1) 1600 3528 0.20 0.1 * Qmax (10:1) 800 1764 0.20 0.05 * Qmax (20:1) 400 880 0.20 0.02 * Qmax (50:1) 160 353 0.50 Typical P in bar (psi) 1 cp 100 cp 1000 cp 0.4 (5.7) 0.8 (11.6) 2.0 (28) 0.1 (0.7) 0.1 (1.1) 0.6 (8) ~ 0 (0.1) ~ 0 (0.4) 0.2 (3) ~ 0 (0) ~ 0 (0.2) 0.1 (2) ~ 0 (0) ~ 0 (0.1) 0.1 (1) 2) Optimized Low Flow Models / optimized to be operated between 0.0165 x Q max and 0.325 x Q max 0.325 * Qmax (1:1) 2600 5732 0.15 0.0325 * Qmax (10:1) 260 572 0.20 0.0165 * Qmax (20:1) 130 286 ~ 0.50 (*) 0.1 (1.6) 0.2 (3.8) 1.0 (14) ~ 0 (0) ~ 0 (0.1) 0.1 (1) ~ 0 (0) ~ 0 (0) ~ 0 (0) (*) around 0.30-0.70 % accuracy depending on the installation conditions 3) Gold Line Models / application fine tuned meters 1 * Qnom (1:1) 5000 11025 0.10 0.25 * Qnom (4:1) 1250 2755 0.12 0.125 * Qnom (8:1) 625 1377 0.15 0.4 (5.7) 0.8 (11.6) 2.0 (28) ~ 0 (0.4) ~ 0 (0.8) 0.5 (6) ~ 0 (0.1) ~ 0 (0.4) 0.2 (3) Repeatability better ± 0.05% of rate Density better than ± 0.0015 g/cc - Gold Line: Field adjustable to better ± 0.001 g/cc Temperature better ± 1 C Standard Models Gold Line Models Error (%) 1,5 P (bar) 1,0 Error (%) 1,5 P (bar) 1,0 1 1 0 0 - - -1-1 -1,5 0,0 0 2000 4000 6000 8000 Flow rate (kg/min) -1,5 0,0 0 1250 2500 3750 5000 Flow rate (kg/min) Data above refer to standard wall thickness. Error of reading (including zero drift) indications refer to reference conditions H 2 O, 18-24 C (66-76 F), 1-3 bar (15-45 psi). RHM sensor do not suffer from pressure effect due to torsional oscillation and semi circle (non-deforming) measurement section. Temperature changes of +/- 25 C around the operating point are negligible. Pressure drop refers to Newton liquids, with parallel measuring loops and block/manifold connection. Nominal flow refers to approx. 10 m/s (33 ft/sec) velocity in measuring loops for best performance. Calibration to customer range, with increased accuracy, possible. RHM 80 Page 2 of 5 / 18 November 2005 - v5

GENERAL DIMENSIONS RHM 80 Type II (sealless welded parallel measuring loops w/o seallings [PF0]) A2 = 1320 mm (51.96") B2 = 403 mm (15.86") H1 = 1505 mm (59.25") H2 = 1775 mm (69.88") W = 150 mm (5.91") Weight: approx. 380 kg (838 lb) Shipping box: approx. 220 x 160 x 90 cm (87 x 63 x 36 inch) Standard Optional Process Connection Face to face length (L) (*) Order Code 6" CL 150 acc. ANSI B16.5 900 mm (35.43") A1 6" CL 300 acc. ANSI B16.5 900 mm (35.43") A2 6" CL 600 acc. ANSI B16.5 900 mm (35.43") A3 DN150 / PN16 acc. DIN 2527 - C 900 mm (35.43") D1 DN150 / PN40 acc. DIN 2527 - C 900 mm (35.43") D2 6" CL 900 acc. ANSI B16.5 900 mm (35.43") A7 6" CL 1500 acc. ANSI B16.5 900 mm (35.43") A9 DN150 / PN100 acc. DIN 2527 - E 900 mm (35.43") D3 (*) Customization possible on request. The finish type of our ANSI flanges is RF/SF (AARH 125-250 (µinch) - Ra 3,2 up to 6,3 (µm)). Others available on request. Above table only shows our general process fittings. For further customization with regard to special fittings and face to face length please contact your local agent. RHM 80 Page 3 of 5 / 18 November 2005 - v5

GENERAL SPECIFICATIONS RHM 80 Approvals ATEX (CESI 02 ATEX 053 X): Ex II 1 G, EEx ia IIC T6-T1 CSA (220705) Class I, Div 1 and 2, Groups A, B, C and D;Type 3 Custody Transfer Approvals (PTB 1.32-97027224 and NMI TC 3382) PED according to directive 97/23/EC available Electrical connection Junction box / aluminium coated (standard) IP 65 (Nema 4X) (Junction box in SS optional) Cable entry M25 x 1.5 (M20 x 1.5, ½" and ¾" NPT optional) Max cable length between RHM and RHE: 100 m (330 ft) 200 m (660 ft) only with factory approval Housing Stainless Steel: 1.4301 / SS 304 - others on request - Protection class: IP 65 (Nema 4X) - higher on request - Material of wetted parts 1.4571 / SS 316Ti (standard) 1.4539 / SS 904L on request Hastelloy C22 on request Other material on request Pressure rating Pressured part of the meter consists of the measuring loops and the connection part. The weaker of both parts decides the maximum allowed operating pressure. Below is the max. operating pressure of the measuring loops (*). (*) These values are only valid for SS 316Ti & SS 904L materials. Statements for others materials on request. Standard version: 100 bar @ 120 C (1450 psi @ 248 F) 90 bar @ 210 C (1305 psi @ 410 F) 75 bar @ 350 C (1085 psi @ 662 F) wall thickness is generally 4.05 mm (0.16") Optional high pressure version: 160 bar @ 120 C (2320 psi @ 248 F) wall thickness is generally 6.3 mm (0.25") Other pressure rating - on request - Temperature rating NT Models from -20 to +120 C (-4 to +248 F) ET Models from -45 to +120 C (-49 to +248 F) ET1 Models from -200 to +50 C (-328 to +122 F) ET2 Models from -45 to +210 C (-49 to +410 C) HT Models from 0 to +350 C (+32 to +662 F) For further information please contact your local representative - to be continued with the order code on the next page - RHM 80 Page 4 of 5 / 18 November 2005 - v5

ORDER CODE RHM 80 Order Code Structure The order code of the Rheonik Sensors consists of 6 sections (see previous pages / below). Restrictions of combinations may apply. For specials, please comment your needs in plain text / sketches. Temperature Rating T1 NT Models (Normal Temperature Models) from -20 to +120 C (-4 to +248 F) TA ET Models (Extended Temperature Models) from -45 to +120 C (-49 to +248 F) T2 ET2 Models (Extended Temperature Models) from -45 to +210 C (-49 to +410 F) T3 ET1 Models (Extended Temperature Models) from -200 to +50 C (-328 to +122 F) T4 HT Models (High Temperature Models) from 0 to +350 C (+32 to +662 F) Pressure Rating P1 Standard pressure version (100 bar @ 120 C / 1450 psi @ 248 F) - page 4 - P2 High pressure version (160 bar 120 C / 2320 psi @ 248 F) - page 4 - PX Other pressure version (on request) - page 4 - Construction Type PF0 Parallel Measuring Loops Seal Less Welded Version - page 3 - XXX Other construction type on request Material of Wetted Parts M1 1.4571 / SS 316Ti M2 1.4539 / SS 904L M3 Hastelloy C22 Process Connection XX Code available on page 3. Hazardous Area Approvals NN Without Ex Approvals AT ATEX Approvals (CESI 02 ATEX 053 X) - Ex II 1 G, EEx ia IIC T6-T1 CS CSA Approvals (220705) - Class 1, Div 1 / Group A, B, C, and D; Type 3 Order Code Example M#80 T1 P1 PF0 M1 A2 AT T1: NT (Normal Temperature Models) from -20 to +120 C (-49 to +248 F) P1: Standard pressure version (100 bar @ 120 C / 1450 psi @ 248 F) PF0: Parallel Measuring Loops Seal Less Welded Version M1: 1.4571 / SS 316 Ti A2: 6" CL 300 acc. ANSI B 16.5 AT: ATEX Approvals (CESI 02 ATEX 053 X) M#80 RHM 80 Page 5 of 5 / 18 November 2005 - v5