Modulating control valve PN16

Similar documents
Modulating control valve PN16 with magnetic actuator

Modulating control valve PN16 with magnetic actuator

Control of cutting-oil emulsion for industrial grinding machines. Applications for CHW and LPHW systems, see data sheet CA1N4454E.

Modulating Control Valve PN 16 with Magnetic Actuator

Modulating control valves with magnetic actuators, PN 16

MVF461H Series Modulating Control Valves with Magnetic Actuators, Positioning Control and Position Feedback for Hot Water and Steam

Modulating control valves with magnetic actuators, PN 16

MXG MXF Modulating control valves PN 16 with magnetic actuators. Building Technologies HVAC Products

Modulating control valves with magnetic actuator PN 16

Modulating control valve with magnetic actuator PN16

Modulating control valves with magnetic actuator PN 16

Modulating control valves PN16 with magnetic actuators

MXF461 U Series Modulating Control Valves with Magnetic Actuators

Cooling water Chilled water Low temperature hot water C Water with anti-freeze (max. 50%vol.)

Two-port seat valves with male thread, PN16

2-Port Seat Valves with Flange, PN 25

2-Port Seat Valves with Flange, PN 25

Differential Pressure Sensors

MXG461.. MXG461..P MXF461.. MXF461..P

3-port seat valves PN16 with flanged connection

2-port seat valves PN25 with flanged connection

3-port seat valves PN40 with flanged connection

Butterfly valves, PN6, PN10, PN16

3-Port Seat Valves with Male Thread, PN 16

Actuators for small valves

2-port ball valves with flanged connection, PN25

3-port seat valves PN16 with flanged connection

3-Port Seat Valves with Flange, PN 6

2-port seat valves PN16 with flanged connection

3-Port Seat Valves with Flange, PN 10

3-port seat valves, external thread, PN16

Product bulletin for: ST2 Ball valves with two-way and three-way BSPP threaded fittings

2-port and 3-port valves with T-bypass PN 16

3-Port Seat Valves with Male Thread, PN 16

Control valves with pneumatic actuators up to 350 C PN

VMP43... Two-port and three-port seat valves PN16. Siemens Building Technologies Landis & Staefa Division

MXG461.. MXG461..P MXF461.. MXF461..P

Combi valves PN 16 with flanged connections

2- and 3-port valves with flanged connections, PN 16

3-port seat valves PN6 with flanged connection

Electric actuators for small valves

2- and 3-port valves with flanged connections, PN 16

Control valves with electric actuators up to 90 C PN

3-port seat valves PN10 with flanged connection

Butterfly valves PN6, PN10, PN16

Differential Pressure Sensors

Pressure sensor for liquid and gaseous media QBE620-P...

Two-port and three-port small valves PN16, ANSI Class 250

ARI-STEVI 440 / 441 DVGW type approval

2-Port and 3-Port Zone Valves PN 16

VBF21.. Three-port slipper valves PN6. Series 02: DN40 and DN50 Series 01: DN

2-port and 3-port terminal unit valves PN16

Mounting and Operating Instructions EB 5868/5869 EN

with electric actuators Feedwater control valve with pump spill back DN

Butterfly valves PN6, PN10, PN16

Series V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator

Motorized Segmented disc valves 5030 DN 25 bis DN 300

ARI-STEVI 450 / 451 (DN15-150) Control valve - 3-way-form (mixing/diverting valve) (optional with screwed seat ring)

Series 02: DN40 and DN50 Series 01: DN Three-port slipper valves PN6

VLF45... Hot Air Valves. Siemens Building Technologies HVAC Products

Flow controller with integrated control valve (PN 16) AHQM return and flow mounting

ATi Max Series. Pressure Independent Control Valves 2 Way 2-1/2-6

Flow controller with integrated control valve (PN 16) AHQM - return and flow mounting

Series 02: DN40 and DN50 Series 01: DN Three-port slipper valves PN6

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

Series V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator

Butterfly valves PN 16

Pressure Independent Control Valve Applications for Building Automation, Temperature Controls, and HVAC Two-Way Chilled Water Hot Water

Electromotoric actuators

ARI-STEVI 450 / 451 (DN15-150) Control valve - 3-way-form (mixing/diverting valve) (optional with screwed seat ring)

3-way control valve in mixing and diverting design

ARI-STEVI 450 / 451 Pneumatic actuator ARI-DP 32-34T. Electric actuator ARI-PREMIO 2,2-25 kn ARI-PREMIO-Plus 2G 2,2-25 kn

2-Port and 3-Port Zone Valves, PN 16 / 20

Electromotoric actuators

VG9000 Flanged Valves

2-Port and 3-Port Zone Valves PN 16

VB-8000 Series VB-9313 Series. Selection Guide. Applications. Applicable Literature. Selection Guide Contents. Valve and Actuator Selection Procedure

Flowrite VF 599 Series Two-Way Valves 2-1/2 to 6-inch Flanged Iron Body

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil

Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator

2-Port and 3-Port Zone Valves & Actuators, PN16

ARI-STEVI 423 / 463 (DN ) Control valve - 3-way-form (mixing/diverting valve) (optional with screwed seat ring)

2- and 3-port valves with flanged connections, PN 16

ARI-STEVI 423 / 463 Pneumatic actuator ARI-DP 34-34T. Electric actuator ARI-PREMIO 5-25 kn ARI-PREMIO-Plus 2G 5-25 kn

High Pressure 2-way 2 1/2-6 Globe Valves

2-Port and 3-Port Zone Valves, PN16

STEVI 450 / way control valve in mixing and diverting design DN

with electric and pneumatic actuators Control valve in 3-way-form (3-way mixing valve) DN 300 ARI-STEVI 423 Electric actuator ARI-PREMIO

Butterfly valves PN 16

Typetested for liquid fuels and liquefied petroleum gas (LPG) in the liquid phase (see Data Sheet T 8022 EN) Version according to ANSI standards

3-port valves vxf42..

Series 240 Type Gas and Type Gas Automatic Shut-off Valves for Gases (valve class D)

Three-port slipper valves PN10, female-threaded

3-port valves. pneumatically actuated

STEVI 440 / 441. Straight through control valve DN

2- and 3-port valves with flanged connections, PN 25

Series 240 Electric Control Valve Type 3241/3274 Globe Valve Type 3241 Electric Control Valve Type 3244/3274 Three-way Valve Type 3244

2- and 3-port valves with flanged connections, PN 6

Hydrocontrol VFC cast iron, PN 16 Hydrocontrol VFR bronze, PN 16 Hydrocontrol VFN nodular cast iron, PN 25 Double regulating and commissioning valves

ARI-STEVI 423 / 463 Pneumatic actuator ARI-DP 34-34T. Electric actuator ARI-PREMIO 5-25 kn ARI-PREMIO-Plus 2G 5-25 kn

Transcription:

8 Modulating control valve PN with magnetic actuator for HTHW and steam, with positioning control and position feedback MH...FY...N Control valve with magnetic actuator for modulating control in district heating systems and HTHW and steam applications Fast positioning time (< s) High resolution (> : 000) High rangeability Closed when de-energised With positioning control and position feedback Low friction, robust and maintenance-free se The MH...FY...N valve types are through-port control valves with a fixed magnetic actuator. The actuator is equipped with connecting electronics for positioning control and position feedback. At zero current the valves are closed. The short positioning time, high resolution and high rangeability make these valves ideal for proportional control of district heating stations and heating plant using HTHW and steam. The low-friction, robust and maintenance-free construction makes regular service unnecessary. Type summary Operating data q [mm ] DN kvs PN Pmed...0 alve type [mm] [m /h] [A] [A] L [m] MHFY0N 0. 0 0 0 MHFYN. 0 0 0 MHFYN.0 0 0 0 MH0FYN 0.0 0 0 0 MHFYN 8.0 0 0 0 MHFYN 0 0 80 MH0FYN 0 0 0 0 0 0 0 MH0FYN 0 0 0 0 0 0 0 Legend see page Siemens Building Technologies CAN8E /.998 Landis & Staefa Division /

Legend : PN = Nominal power Pmed = Mean operating power kvs = Flow rate to DI/DE7, tolerance ±0 % q = Cross section of AC or DC 0 cable (Cu) L = Max. cable length. With -wire connections, the maximum length of a separate. mm Cu control signal cable may be extended to 00 m. Ordering The valves are supplied complete with the magnetic actuator and the terminal housing. The Z00/... damping device can be ordered on request: see 'Accessories'. When placing an order, please specify the quantity, product description and type code. Example: control valve MHFYN and damping device Z00/ Technical / Mechanical design The control signal is converted in the terminal housing into a phase cut signal which generates a magnetic field in the coil. This causes the only moving part, the armature, to change its position in accordance with the interacting forces (magnetic field, counterspring, hydraulics etc.). The armature responds rapidly to any change in signal, transferring the corresponding movement directly to the control disc, enabling fast changes in load to be corrected quickly and accurately. The valve position is measured continuously. Any disturbance in the system is rapidly corrected by the internal positioning controller, which ensures that the control signal and the valve stroke are exactly proportional, and also provides a feedback signal indicating the valve position. Stroke [%] 00 9.000 80 0 0 0 0 0 8 0 Control signal [] If the power is switched off or fails, the valve is automatically closed by the force of the spring. The valve stem is sealed with a maintenance-free O-ring gland. See sheet 08 for a detailed description of operation. Manual adjustment Accessories The control path can be opened mechanically to between 0 and approximately 90 %, by turning the handwheel clockwise. The manual adjustment facility can also be used as a mechanical method of low limit control, i.e. the valve will exercise its normal control function between the manually-set position and the 00 % open position. For full-stroke automatic control, the handwheel must be set to 0 (the anticlockwise end-stop). Z00/... Damping device to extend the closing time from <s to 0... 0 s. See sheet 97. See sheet 000 for an overview of water and steam valves. CAN8E /.998 Siemens Building Technologies / Landis & Staefa Division

Sizing Water flow chart Flow / pressure differential relationship. kvs signifies the volume of water in m /h, which flows through the open valve at a pressure differential pv of 00 kpa ( bar). See sheet 0 for notes on calculating the value of kvs. [m /h]. 9IE [l / s] 00 70 0 0 0 0 0 7 0,7 0, 0, 0, 0, MH..FY..N S DN0 k 0 S DN0 k 0 S DN k S DN k 8 S DN0 k S DN k S DN k, DN S k 0, 0 0 7 0,7 0, 0, 0, 0, 0, 0,07 0,0 0 0 0 0 70 00 00 00 00 700 000 [kpa] 0, 0, 0, 0, 0,7 7 0 [b ar] p v Saturated steam flow chart 9I7E p v p 00 [ ] MH..FY..N b a 0,, 8 0 0 0, 0,0 0,0 0, 0,0 0,0 00 00 00 00 000 [kpa] 7 0 [bar] p 7 0 7 0 7 0 [kg/h]. m Mounting notes Two sets of mounting instructions are enclosed with the valve: Ref. 0 (valve) and Ref. 77 (terminal housing). Warning : Always disconnect the power before fitting or removing the terminal housing. The terminal housing is calibrated and matched to the actuator, and should be replaced only by qualified personnel. A fine mesh strainer installed on the inlet side of the valve is essential to prevent the ingress of grit. ertical to horizontal mounting: Protection standard IP. The valve must not be suspended below the horizontal. The actuator must not be lagged. For special information on use in steam applications, see sheet 0. Siemens Building Technologies CAN8E /.998 Landis & Staefa Division /

Recommendation Water systems should be cleaned, flushed and treated in accordance with current good practice, as described, for example, in BSRIA Application Guides AG 8/9 and AG/9. For other relevant information, see also CIBSE Guide B (Section 7). Technical data Electrical interface: Only admissisble with low voltage (SEL, PEL) Supply voltage AC, 0/0 Hz Max. voltage tolerance +/ 0 % Nominal power See table 'Operating data' page Control signal DC 0...0 or DC... 0 ma Position feedback (output signal) DC 0...0 = 0...00 % stroke Max. load. ma Accuracy ± % of full scale Nominal pressure PN Operating pressure p e max: Water up to 0 C. MPa ( bar) Above 0 C. MPa ( bar) Saturated steam 0.9 MPa ( 9 bar) Pressure differential p v max.0 MPa (0 bar) Leakage at p v = 0. MPa ( bar) Max. 0.0 % k vs (to DE/DI7) Temperature of medium...80 C alve characteristic (stroke, k v ) Linear, optimised in low opening range Resolution H / H00 > : 000 (H = Stroke) Type of operation Modulating Manual adjustment p to max. 90 %, depending on DN Position when de-energised Closed Orientation pright to horizontal Positioning time *) < s Materials: Housing Spheroidal graphite cast iron (GGG0.) Seat / inner valve CrNi steel alve stem seal EPDM (O ring) Connection terminals Screw terminals for mm wire Protection standard pright to horizontal mounting IP to IEC9 Ambient temperature... 0 C Weight (incl. packaging) See table 'Dimensions' on page Conformity Meets the requirements for CE marking *) The valve can be fitted with a Z00/... damping device to achieve a slower closing time of 0... 0 s. Internal diagram NS = system ground LS ~ G + AC NS T M 0 Block diagram of signal converter Input DC 0...0 Output DC... 0 ma R T + E Q Position transducer Output DC 0...0 Position-feedback electronics with base/span adjustment Key to block diagram E Phase cut converter G Bridge rectifier M Magnetic valve Q Phase cut output R T Input resistor 0 k ohms oltage / current converter (load on 0 ohms to NS) Position / voltage converter Differential amplifier CAN8E /.998 Siemens Building Technologies / Landis & Staefa Division

Connection terminals Warning : If the controller and the valve receive their supply from a separate source, the valve transformer must not be earthed on the secondary side. 0B ~ TE AC supply Input DC 0...0 Output DC 0...0 Input DC... 0 ma Connection diagrams with DESIGO 0 with INTEGRAL RS refer to manual R refer to manual K with MLTIREG Warning : The T transformer must not be earthed on the secondary side and should be suitably fused. T T AC AC RPR MH...FY...N 0en AC GND Output DC 0...0 Input DC 0...0 9 ) alve position indication DC 0...0 = 0...0 % ) ~ AC Supply Input DC 0..0 Output DC 0..0 T E with other controllers (output DC 0...0 ) T AC MH...FY...N 0en Output DC 0...0 alve position indication DC 0...0 = 0...00 % ) ~ T E AC Supply Input DC 0...0 Output DC 0...0 with other controllers (output DC... 0 ma) T AC MH...FY...N 099en Output DC... 0 ma alve position indication DC 0...0 = 0...00 % ) ~ AC Supply Output DC 0... 0 Input DC... 0 ma T E ) only if needed Siemens Building Technologies CAN8E /.998 Landis & Staefa Division /

Application examples Examples of installation in straight-through applications (principles only, without installation-specific details) 9H808 A 9H807 A D E D : District heating (supply heating) system, indirect connection E : District heating (supply heating) system, directly connected to water-heating system. Dimensions All dimensions in mm 90 min. 00 ø 0 F ø E H Cable connection max. x ø,8 b ø d ø k ø D Flange dimensions to DIN, PN DN L alve type L ø D ø d b ø k H ø E F W MHFY...N 0 9 x 8 80 8 7. MH0FYN 0 0 x 7 0 80 8 8. MHFYN 0 x 8 8 80 8 9. MHFYN 80 0 x8 8 00 7 00 9. MH0FYN 00 0 x8 8 0 00 9.8 MH0FYN 0 x8 0 8 08 7.0 W = Weight (incl. packaging) in kg 998 Siemens Building Technologies Ltd. CAN8E /.998 Siemens Building Technologies / Landis & Staefa Division