Protistor size 14x51 ar 690VAC (IEC) / 700VAC (UL)

Similar documents
Protistor size 70 gr 690VAC (IEC)

NH fuse-links am VAC with striker, size 0, 1, 2, 3, 4

Protistor size 31 ar 690VAC (IEC) / 700VAC (UL)

NH fuse-links gg 400VAC double indicator/live gripping-lugs size 000, 00, 1, 2, 3

NH fuse-links am 690VAC top indicator/live tags size 4, 4a

NH fuse-links gg 500VAC top indicator/live gripping-lugs size 4, 4a

NH fuse-links gg 690VAC top indicator/live gripping-lugs size 4 and 4a

Protistor size 120 gr 750VDC (IEC)

Limitor -G General Purpose Fuses

NH fuse-links gg 500VAC size 000, 00, 0, 1, 2, 3

NEOZED D0 fuse-links gg 400/440VAC

Fuses for Semiconductor Protection - European Standard. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits

onlinecomponents.com

Semiconductor Fuses European Fuses

HelioProtection HP10NH Photovoltaic fuse-links gpv 1000VDC

Select 700V/ ysuk.com. The. Current limiting. acceptance. protection of. within a single. recognised (10 38 fuses) October 2013

HelioProtection HP15NH Photovoltaic fuse-links gpv 1500VDC

Selector guide. PSC Square body fuses Size 3X VAC End Contact Terminals. Features and Benefits

NH Solid Blades 690 VAC sizes 000 to 3

Fuses for Semiconductor Protection European Standard Sizes 000 and 00. Protection of Power Semiconductors according to IEC and -4

HelioProtection HP15NH3L Photovoltaic fuse-links gpv 1500VDC

Semiconductor (AC) fuses

Low-Peak 600V Class RK1

Modulostar CMS10 Modular fuse-holders

gi-gl-gg, am gi-gl-gg gi-gl-gg NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories

General Purpose US Fuses

KLKD SERIES 10x38 FUSES

Semiconductor (AC) fuses

Selector guide. PSC Square body fuses Size 3X VAC Blade Terminals. Features and Benefits

LENRK/LESRK CLASS RK1 DUAL ELEMENT TIME-DELAY FUSES

British BS 88 Fuses. High Speed Fuses. Introduction. General Information

Accessories. For product data sheets, visit

Modulostar US10 Modular fuse-holders

UltraSafe US22 Modular fuse-holders

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse

gg, am NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories NH DIMENSION KNIFE-BLADE FUSE-LINKS, FUSE BASES, AND ACCESSORIES

PSC SQUARE BODY 690/700 Volt SEMICONDUCTOR PROTECTION FUSES

DIN Dual indication fuse links

Short Circuit. Sizes 0, 1, 2, and 690 Volt ratings - 32A through 630A All ratings include striker. 0% Lead

HHB. Medium Voltage Fuses British Standard. Introduction. Fuse-links for oil insulated switchgear

RAPIDPLUS. high speed fuse links for semiconductors

RAPIDPLUS. high speed fuse links for semiconductors

Page 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC.

CL-14 SERIES E-RATED / MEDIUM VOLTAGE FUSES

Ferrule fuses. High Speed Fuses

Medium voltage fuses Medium voltage fuses

LPCC3 3A 600V TD Class CC Low Peak Fuse. Features amperage rating. Dimensions and Weight. Long Description. Manufacturer Information

Bussmann 10x38mm Photovoltaic fuses 1000Vdc, 1-30A

Low-Peak LPJ Class J 600Vac/300Vdc, 1-60A, dual element, time-delay fuses

LPSRK30SP 30A 600V TD Dual Elem Class RK1 Low Peak Fuse

Fuse holders and fuses

CS-3 SERIES E-RATED/MEDIUM VOLTAGE FUSES

High reliability against cyclic and peak current loads / age resistant due to high motor start up currents

fuses fuse holders CYLINDRICAL

UL248 North American Low Voltage Fuses

NH DIN Dual Indication Fuse Links Class am, 690Vac, 6 to 500 Amps, Sizes 000 to 3 NH Series

Synergy EN product information

MULTIBLOC 000.ST8 Size 000, 100A, 690VAC, Design for Bottom Fitting, Triple Pole

Amp-Trap 2000 Fuses FOR TYPE 2, NO DAMAGE CIRCUIT PROTECTION IN ALL THE CONFIGURATIONS YOU NEED. Class J / AJT...A2. AJT Reducer Fuses...

LINOCUR Size D02 63A 230VAC/440VAC

MEDIUM VOLTAGE FUSES FOR CAPACITORS NORTH AMERICAN STYLE

D Type (DIAZED) FUSE-LINKS & SCREW CAP HOLDERS. EURO/IEC Fuses & Accessories 500 VOLT D TYPE DIAZED FUSE-LINKS, SCREW CAPS AND FUSE BASES

Rated Current (Amps) Power Loss (Watts) 0.8 x I n 1 x I n PVM PVM PVM

High Speed Fuses. Section Contents Page

UL 508 Non-Fusible Disconnect Switches

CL-14 SERIES E-RATED / MEDIUM VOLTAGE FUSES

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

Ultra Rapid Fuses. For Semiconductor Protection

NH fuse-links gtr 400VAC top indicator/live gripping-lugs size 2, 3, 4a

MEDIUM VOLTAGE DIN Fuse-Links

N0N A 250V One-Time Class H Fuse

MULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole

UL 508 Non-Fusible Disconnect Switches

TELECOMMUNICATIONS SPECIAL PURPOSE FUSES

BUSSMANN. LIMITRON FNQ-R Class CC 600Vac, A, time-delay fuses SERIES. Technical Data Carton quantity: Catalog symbol: Dimensions - in:

Fuses Special Purpose

FLQ4 4A 500V TD CT Midget Fuse. Descriptions 4A 500V TD CT MIDGET FUSE Time Delay Midget Fuse 4 Amp. Manufacturer Information

Bussmann series NH catalogue. Leadership in circuit protection

Control Circuit Protection

INNOZED D0 fuse-bases with touch protection

High-voltage high-breaking capacity VV fuse-links

MULTIFIX 60 Universal Bus Bar Carriers

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

E-RATED/MEDIUM VOLTAGE FUSES

LG HRC Power Fuses ISO 9001 ISO 14001

HIGH-SPEED SEMICONDUCTOR FUSES CATALOG POWR-SPEED PRODUCTS HIGH-SPEED FUSES FUSE BLOCKS & HOLDERS

ACW Molded-Case Circuit Breaker UL 489 Listed

LOW-PEAK Time-Delay Fuses KRP-C Class L 600 Volt A

FLQ /2A 500V TD CT Midget Fuse. Long Description. Manufacturer Information. Taxonomies, Classifications, and Categories

Series KTU7 UL489 Molded Case Circuit Breakers

Fusetron FRN-R Class RK5 250Vac/125Vdc A, dual element, time-delay fuses

WARNING Personnel and property must be protected against the consequence of component break-down internally in the frequency converter.

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

Phase + Neutral, neutral on left side

Selection Guide. HHD-BPT, DIN Style, Current-Limiting, Back-Up, Potential Transformer Protection

A240R/A480R/A072F/A072B MED. VOLTAGE FUSES / R-RATED

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

1489-M Circuit Breakers

Leadership in Circuit Protection

MEDIUM VOLTAGE DIN Fuse-Links

Transcription:

690VAC (IEC) / VAC (UL) Protistor size 14x51 ar 690VAC (IEC) / VAC (UL) SEMICONDUCTOR PROTECTION FUSES IEC HIGH-SPEED CYLINDRICAL FUSE-LINKS AC PROTECTION FEATURES & BENEFITS Low l²t for improved semiconductor protection Extremely fast acting Current limiting Excellent cycling capability UL recognized ar-class according to 60269-4 APPLICATIONS These Protistor size 14x51 have been designed to protect power semi conductors, complying with standard IEC 60269-4. They are extremely high interrupting rating fuses with large band of ratings (current rating 6 to 63A). Two models are existing: with or without striker. TECHNICAL DATA OVERVIEW Voltage AC 690 VAC AC IEC: 690V Rated Voltage AC UL: V DC UL: V Ampere Range (A) 6... 63 A Speed/Characteristic ar I.R. AC (IEC) 160 ka I.R. AC (UL) ka I.R. DC (UL) ka Small inverters UPS systems Variable speed drives Other similar V or less equipments STANDARDS IEC 60269-4 UL recognized CSA RoHS compliant EP.MERSEN.COM 1

690VAC (IEC) / VAC (UL) PRODUCT RANGE Size 14x51 ar with striker Catalog Item Rated voltage AC (IEC) Rated current In Pre-arcing I²t Clearing I²t at Rated Voltage Rated breaking capacity AC Power dissipation at In Package Weight FR14AR69V6T P56656 690 V 6 A 2.4 A²s A²s 160 ka 1.5 W g FR14AR69V8T Q56657 690 V 8 A 3.3 A²s A²s 160 ka 2 W g FR14AR69VT R56658 690 V A 4.3 A²s 40 A²s 160 ka 3 W g FR14AR69V12T S56659 690 V 12 A 5.4 A²s 55 A²s 160 ka 4 W g FR14AR69V16T T56660 690 V 16 A 11.3 A²s A²s 160 ka 5 W g FR14AR69VT V56661 690 V A 21.7 A²s 160 A²s 160 ka 5.5 W g FR14AR69V25T W56662 690 V 25 A 45.3 A²s 345 A²s 160 ka 6 W g FR14AR69V32T X56663 690 V 32 A 77.4 A²s A²s 160 ka 7.7 W g FR14AR69V40T Y56664 690 V 40 A 129.6 A²s 8 A²s 160 ka 9.2 W g FR14AR69VT Z56665 690 V A 241.1 A²s 1 A²s 160 ka 11.2 W g FR14AR69V63T A56666 690 V 63 A 428.6 A²s 2600 A²s 160 ka 14.3 W g Size 14x51 ar without striker Catalog Item Rated voltage AC (IEC) Rated current In Pre-arcing I²t Clearing I²t at Rated Voltage Rated breaking capacity AC Power dissipation at In Package Weight FR14AR69V6 H27325 690 V 6 A 2.4 A²s A²s 160 ka 1.5 W g FR14AR69V8 J27326 690 V 8 A 3.3 A²s A²s 160 ka 2 W g FR14AR69V K27327 690 V A 4.3 A²s 40 A²s 160 ka 3 W g FR14AR69V12 L27328 690 V 12 A 5.4 A²s 55 A²s 160 ka 4 W g FR14AR69V16 M27329 690 V 16 A 11.3 A²s A²s 160 ka 5 W g FR14AR69V N273 690 V A 21.7 A²s 160 A²s 160 ka 5.5 W g FR14AR69V25 P27331 690 V 25 A 45.3 A²s 345 A²s 160 ka 6 W g FR14AR69V32 Q27332 690 V 32 A 77.4 A²s A²s 160 ka 7.7 W g FR14AR69V40 R27333 690 V 40 A 129.6 A²s 8 A²s 160 ka 9.2 W g FR14AR69V S27334 690 V A 241.1 A²s 1 A²s 160 ka 11.2 W g FR14AR69V63 T27335 690 V 63 A 428.6 A²s 2600 A²s 160 ka 14.3 W g EP.MERSEN.COM 2

690VAC (IEC) / VAC (UL) TIME CURRENT CHARACTERISTIC CURVES 0 Pre-arcing time (s) C C' 6 A 7 5 3 8 A A 2 12 A 1 0.7 0.5 0.3 16 A A 0.2 25 A 0.1 0.07 0.05 0.03 32 A 40 A 0.02 0.01 0.007 0.005 0.003 0.002 0.001 0.0007 0.0005 0.0003 0.0002 0.0001 RMS value of prospective current (A) +/- 8% 0 A 63 A 0 0 0 0 00 EP.MERSEN.COM 3

690VAC (IEC) / VAC (UL) CUT-OFF CURRENT CHARACTERISTIC 00 Maximum peak let thru current Ic (A) 00 00 0 0 0 0 0 lm = 2.3 lp 63 A A 40 A 32 A 25 A A 16 A 12 A A 8 A 6 A 0 0 0 0 0 00 00 00 00 00 000 000 000 Hz RMS symmetrical prospective current Ip (A) I²T MULTIPLIER COEFFICIENT Clearing I²t and arcing time correction factor 1,1 1 0,9 0,8 0,7 0,6 0,5 0,4 0,3 400 Applied AC voltage (V) 600 800 EP.MERSEN.COM 4

690VAC (IEC) / VAC (UL) CHARACTERISTICS TOTAL I²T CURVE Operating I²t (A²s) 00 0 0 0 0.0ms(5.00ms).0ms(2.80ms) 7.9ms(1.60ms) 4.4ms(0.80ms) 2.5ms(0.40ms) 1.4ms(0.ms) 0.8ms(0.ms) 63 A A 40 A 0 32 A 25 A A 16 A 12 A A 8 A 6 A POWER DISSIPATION Correction factor for power dissipation 1 0,8 0,6 0,4 0,2 0 0 0 0 0 0 00 Hz RMS symetrical prospective current (Ip)(A) 40 60 80 % of rated current 00 90 00 00 00 000 000 000 000 000 1e+06 EP.MERSEN.COM 5

690VAC (IEC) / VAC (UL) PEAK ARC VOLTAGE 1 Peak arc voltage (V) 1400 1 1 1 0 900 800 600 400 600 800 Applied AC voltage (V) DIMENSIONS Size 14x51 ar without striker Size 14x51 ar with striker +0.6 51-1 Dimensions in mm Ø 14.3 ± 0.1 +0.6 51-1 0.5 Dimensions in mm Visual indicator Ø 14.3 ± 0.1 EP.MERSEN.COM 6