Protistor size 31 ar 690VAC (IEC) / 700VAC (UL)
|
|
- Dale Simpson
- 5 years ago
- Views:
Transcription
1 Protistor size 31 ar SEMICONDUCTOR PROTECTION FUSES SQUARE BODY HIGH-SPEED FUSE-LINKS AC PROTECTION FEATURES & BENEFITS Multiple body sizes and terminals or blades combination ar Class according to IEC and VDE Very low I²t for improved semiconductor protection Ultra fast acting Current limiting Superior cycling capability APPLICATIONS The 69/7V Protistor fuse-links provide maximum flexibility in equipment design and ultimate protection for today s power conversion equipment. These ar ultra-fast acting square body fuse-links are available in different body sizes, each size having multiple worldwide acceptable mounting styles. They have been engineered to provide state-of-the-art protection for semiconductors: diodes, thyristors and IGBT devices. They are assembled with die-cut elements embedded in solidified sand, which helps control arcing characteristics for a lower I²t and high interrupting rating level. All contact surfaces are silver plated and all hardware is non-magnetic. Each fuse-link can be equipped with a low voltage trip-indicator which can operate a field mountable microswitch. TECHNICAL DATA OVERVIEW Voltage AC 69 VAC Ampere Range (A) A Speed/Characteristic ar I.R. AC (IEC) 17 ka Product Size 31 Protection of inverters, motor drives, UPS systems and similar 69V or less equipments. STANDARDS IEC Compliance UL/CSA Recognized E76491 CCC GB EP.MERSEN.COM 1
2 PRODUCT RANGE Size 31 type TTF M8 threaded terminals PC31UD69V8TF (IEC) (UL) current In Pre-arcing I²t Clearing I²t at Voltage breaking capacity AC Power dissipation at In Package Weight PC31UD69V16TF M V 7 V 16 A 13 A²s 77 A²s 2 ka 35 W 3.38 kg PC31UD69V2TF N31 69 V 7 V 2 A 26 A²s 15 A²s 2 ka 45 W 3.38 kg PC31UD69V25TF P32 69 V 7 V 25 A 47 A²s 28 A²s 2 ka 52 W 3.38 kg PC31UD69V315TF Q33 69 V 7 V 315 A 75 A²s 44 A²s 2 ka 65 W 3.38 kg PC31UD69V35TF M V 7 V 35 A 13 A²s 61 A²s 2 ka 67 W 3.38 kg PC31UD69V4TF R34 69 V 7 V 4 A 19 A²s 11 A²s 2 ka 68 W 3.38 kg PC31UD69V45TF S35 69 V 7 V 45 A 265 A²s 155 A²s 2 ka 7 W 3.38 kg PC31UD69V5TF T36 69 V 7 V 5 A 37 A²s 215 A²s 2 ka 7 W 3.38 kg PC31UD69V55TF V37 69 V 7 V 55 A 52 A²s 31 A²s 2 ka 7 W 3.38 kg PC31UD69V63TF W38 69 V 7 V 63 A 75 A²s 43 A²s 2 ka 75 W 3.38 kg PC31UD69V7TF X39 69 V 7 V 7 A 95 A²s 54 A²s 2 ka 85 W 3.38 kg PC31UD69V8TF Y V 7 V 8 A 14 A²s 88 A²s 2 ka 15 W 3.38 kg Size 31 type TTI 5/16-18 unified coarse threaded terminals A7UD31TTI8 (IEC) (UL) current In Pre-arcing I²t Clearing I²t at Voltage breaking capacity AC Power dissipation at In Package A7UD31TTI2 A V 7 2 A 26 A²s 15 A²s 2 ka 45 W 3.39 kg A7UD31TTI25 B V 7 25 A 47 A²s 28 A²s 2 ka 52 W 3.39 kg A7UD31TTI315 C V A 75 A²s 44 A²s 2 ka 65 W 3.39 kg A7UD31TTI35 D V 7 35 A 13 A²s 61 A²s 2 ka 67 W 3.39 kg A7UD31TTI4 E V 7 4 A 19 A²s 11 A²s 2 ka 68 W 3.39 kg A7UD31TTI45 F V 7 45 A 265 A²s 155 A²s 2 ka 7 W 3.39 kg A7UD31TTI5 G V 7 5 A 37 A²s 215 A²s 2 ka 7 W 3.39 kg A7UD31TTI55 H V 7 55 A 52 A²s 31 A²s 2 ka 7 W 3.39 kg A7UD31TTI63 J V 7 63 A 75 A²s 43 A²s 2 ka 75 W 3.39 kg A7UD31TTI7 K V 7 7 A 95 A²s 54 A²s 2 ka 85 W 3.39 kg A7UD31TTI8 L V 7 8 A 14 A²s 88 A²s 2 ka 15 W 3.39 kg Weight EP.MERSEN.COM 2
3 PRODUCT RANGE Size 31 type DIN8 blades PC31UD69V8A (IEC) (UL) current In Pre-arcing I²t Clearing I²t at Voltage breaking capacity AC Power dissipation at In Package Weight PC31UD69V16A M V 7 V 16 A 13 A²s 77 A²s 2 ka 35 W 3.39 kg PC31UD69V2A Y31 69 V 7 V 2 A 26 A²s 15 A²s 2 ka 45 W 3.39 kg PC31UD69V25A Z V 7 V 25 A 47 A²s 28 A²s 2 ka 52 W 3.39 kg PC31UD69V315A A V 7 V 315 A 75 A²s 44 A²s 2 ka 65 W 3.39 kg PC31UD69V35A Q V 7 V 35 A 13 A²s 61 A²s 2 ka 67 W 3.39 kg PC31UD69V4A B V 7 V 4 A 19 A²s 11 A²s 2 ka 68 W 3.39 kg PC31UD69V45A C V 7 V 45 A 265 A²s 155 A²s 2 ka 7 W 3.39 kg PC31UD69V5A D V 7 V 5 A 37 A²s 215 A²s 2 ka 72 W 3.39 kg PC31UD69V55A E V 7 V 55 A 52 A²s 31 A²s 2 ka 75 W 3.39 kg PC31UD69V63A F V 7 V 63 A 75 A²s 43 A²s 2 ka 85 W 3.39 kg PC31UD69V7A G V 7 V 7 A 95 A²s 54 A²s 2 ka 95 W 3.39 kg PC31UD69V8A D V 7 V 8 A 14 A²s 88 A²s 2 ka 12 W 3.39 kg Size 31 type DIN11 blades (IEC) (UL) current In Pre-arcing I²t Clearing I²t at Voltage breaking capacity AC Power dissipation at In Package Weight PC31UD69V2D1A H V 7 V 2 A 26 A²s 15 A²s 2 ka 45 W 3.41 kg PC31UD69V25D1A J32 69 V 7 V 25 A 47 A²s 28 A²s 2 ka 52 W 3.41 kg PC31UD69V315D1A K V 7 V 315 A 75 A²s 44 A²s 2 ka 65 W 3.41 kg PC31UD69V35D1A P V 7 V 35 A 13 A²s 61 A²s 2 ka 67 W 3.41 kg PC31UD69V4D1A L V 7 V 4 A 19 A²s 11 A²s 2 ka 68 W 3.41 kg PC31UD69V45D1A M V 7 V 45 A 265 A²s 155 A²s 2 ka 7 W 3.41 kg PC31UD69V5D1A N V 7 V 5 A 37 A²s 215 A²s 2 ka 72 W 3.41 kg PC31UD69V55D1A P V 7 V 55 A 52 A²s 31 A²s 2 ka 75 W 3.41 kg PC31UD69V63D1A Q V 7 V 63 A 75 A²s 43 A²s 2 ka 85 W 3.41 kg PC31UD69V7D1A R V 7 V 7 A 95 A²s 54 A²s 2 ka 95 W 3.41 kg PC31UD69V8D1A H V 7 V 8 A 14 A²s 88 A²s 2 ka 12 W 3.41 kg Size 31 type KI short slotted blades (IEC) (UL) current In Pre-arcing I²t Clearing I²t at Voltage breaking capacity AC Power dissipation at In Package A7UD31KI16 F V 7 V 16 A 13 A²s 77 A²s 2 ka 35 W 3.4 kg A7UD31KI2 S V 7 V 2 A 26 A²s 15 A²s 2 ka 45 W 3.4 kg A7UD31KI25 T V 7 V 25 A 47 A²s 28 A²s 2 ka 52 W 3.4 kg A7UD31KI315 V33 69 V 7 V 315 A 75 A²s 44 A²s 2 ka 65 W 3.4 kg A7UD31KI35 R35 69 V 7 V 35 A 13 A²s 61 A²s 2 ka 67 W 3.4 kg A7UD31KI4 W V 7 V 4 A 19 A²s 11 A²s 2 ka 68 W 3.4 kg A7UD31KI45 X V 7 V 45 A 265 A²s 155 A²s 2 ka 7 W 3.4 kg A7UD31KI5 Y V 7 V 5 A 37 A²s 215 A²s 2 ka 72 W 3.4 kg A7UD31KI55 Z V 7 V 55 A 52 A²s 31 A²s 2 ka 75 W 3.4 kg A7UD31KI63 A V 7 V 63 A 75 A²s 43 A²s 2 ka 85 W 3.4 kg A7UD31KI7 B V 7 V 7 A 95 A²s 54 A²s 2 ka 95 W 3.4 kg A7UD31KI8 A V 7 V 8 A 14 A²s 88 A²s 2 ka 12 W 3.4 kg Weight EP.MERSEN.COM 3
4 PRODUCT RANGE Size 31 type LI long slotted blades A7UD31LI8 (IEC) (UL) current In Pre-arcing I²t Clearing I²t at Voltage breaking capacity AC Power dissipation at In Package Weight A7UD31LI2 V V 7 V 2 A 26 A²s 15 A²s 2 ka 45 W 3.42 kg A7UD31LI25 W V 7 V 25 A 47 A²s 28 A²s 2 ka 52 W 3.42 kg A7UD31LI315 X V 7 V 315 A 75 A²s 44 A²s 2 ka 65 W 3.42 kg A7UD31LI35 Y37 69 V 7 V 35 A 13 A²s 61 A²s 2 ka 67 W 3.42 kg A7UD31LI4 Z V 7 V 4 A 19 A²s 11 A²s 2 ka 68 W 3.42 kg A7UD31LI45 A V 7 V 45 A 265 A²s 155 A²s 2 ka 7 W 3.42 kg A7UD31LI5 B V 7 V 5 A 37 A²s 215 A²s 2 ka 72 W 3.42 kg A7UD31LI55 C V 7 V 55 A 52 A²s 31 A²s 2 ka 75 W 3.42 kg A7UD31LI63 D V 7 V 63 A 75 A²s 43 A²s 2 ka 85 W 3.42 kg A7UD31LI7 E V 7 V 7 A 95 A²s 54 A²s 2 ka 95 W 3.42 kg A7UD31LI8 F V 7 V 8 A 14 A²s 88 A²s 2 ka 12 W 3.42 kg Size 31 for type EF blade bolted connections PC31UD69V7EF (IEC) (UL) current In Pre-arcing I²t Clearing I²t at Voltage breaking capacity AC Power dissipation at In Package PC31UD69V16EF B V 7 V 16 A 13 A²s 77 A²s 2 ka 35 W 3.4 kg PC31UD69V2EF C V 7 V 2 A 26 A²s 15 A²s 2 ka 45 W 3.4 kg PC31UD69V25EF D V 7 V 25 A 47 A²s 28 A²s 2 ka 52 W 3.4 kg PC31UD69V315EF E V 7 V 315 A 75 A²s 44 A²s 2 ka 65 W 3.4 kg PC31UD69V35EF N V 7 V 35 A 13 A²s 61 A²s 2 ka 67 W 3.4 kg PC31UD69V4EF F34 69 V 7 V 4 A 19 A²s 11 A²s 2 ka 68 W 3.4 kg PC31UD69V45EF G V 7 V 45 A 265 A²s 155 A²s 2 ka 7 W 3.4 kg PC31UD69V5EF H V 7 V 5 A 37 A²s 215 A²s 2 ka 72 W 3.4 kg PC31UD69V55EF J V 7 V 55 A 52 A²s 31 A²s 2 ka 75 W 3.4 kg PC31UD69V63EF K V 7 V 63 A 75 A²s 43 A²s 2 ka 85 W 3.4 kg PC31UD69V7EF L V 7 V 7 A 95 A²s 54 A²s 2 ka 95 W 3.4 kg Weight EP.MERSEN.COM 4
5 TIME CURRENT CHARACTERISTIC CURVES 1 Pre-arcing time (s) C a = 13 A2 =.6 B1 = 1.25 B2 =.6 Cf3 =.8 16 A 2 A 25 A 315 A 35 A 4 A A 5 A C 55 A 63 A.3 7 A.2 8 A RMS value of prospective current (A) +/- 8% EP.MERSEN.COM 5
6 CUT-OFF CURRENT CHARACTERISTIC 5 8 A Maximum peak let thru current Ic (A) lm = 2.3 lp 7 A 63 A 55 A 5 A 45 A 4 A 35 A 315 A 25 A 2 A 16 A e+6 5 Hz RMS symmetrical prospective current Ip (A) I²T MULTIPLIER COEFFICIENT Clearing I²t and arcing time correction factor 1,1 1,9,8,7,6,5,4,3, Applied AC voltage (V) EP.MERSEN.COM 6
7 CHARACTERISTICS TOTAL I²T CURVE Operating I²t (A²s) 2e+6 1e ms (5.ms) 1.ms (3.ms) 8.4ms (2.ms) 6.3ms (1.5ms) 5.ms (1.2ms) 4.1ms (1.ms) 2.8ms (.7ms) 2.ms (.5ms) 1.5ms (.4ms) 8 A 7 A 63 A 3 55 A 2 5 A 45 A 1 4 A A 315 A 3 25 A 2 2 A A e+6 POWER DISSIPATION Correction factor for power dissipation 1,8,6,4,2 5Hz RMS symetrical prospective current (Ip)(A) % of rated current 9 1 EP.MERSEN.COM 7
8 PEAK ARC VOLTAGE 14 Peak arc voltage (V) Applied AC voltage (V) EP.MERSEN.COM 8
9 DIMENSIONS Size 31 type DIN 11 Striker 11.1 Microswitch Indicator lever visible after operation of fuse = 51-2 = = 51 = Dimensions in mm = 25 = 44 EP.MERSEN.COM 9
10 DIMENSIONS Size 31 type DIN 8 Striker 6 4 = 51-2 = = 51 = Microswitch Dimensions in mm Indicator lever visible after operation of fuse = 25 = 6 EP.MERSEN.COM 1
11 DIMENSIONS Size 31 type EF 11.1 Indicator lever visible after operation of fuse Dimensions in mm Microswitch Striker 6 4 = 51-2 = = 51 = EP.MERSEN.COM 11
12 DIMENSIONS Size 31 type LI Striker Indicator lever visible after operation of fuse 51 Dimensions in mm Microswitch 47.6 max 91.6 ± ± ± EP.MERSEN.COM 12
13 DIMENSIONS Size 31 type TTF & TTI Striker Microswitch Dimensions in mm Ø ± Anti-rotation hole Ø 5 Ø 3 Indicator lever visible when the fuse has blown TTI: 2x Ø 5 / 16 UNC TTF: 2x M 8 EP.MERSEN.COM 13
14 DIMENSIONS Size 31 type KI Microswitch Indicator lever visible after operation of fuse Striker max Dimensions in mm APPENDIX Index 68 ± ± ± 1.3 Description 1 PC31UD69V16TF M3299 6,9 URD 31 TT F 16 2 PC31UD69V2TF N31 6,9 URD 31 TT F 2 2 PC31UD69V25TF P32 6,9 URD 31 TT F 25 2 PC31UD69V315TF Q33 6,9 URD 31 TT F PC31UD69V35TF M346 6,9 URD 31 TT F 35 2 PC31UD69V4TF R34 6,9 URD 31 TT F 4 2 PC31UD69V45TF S35 6,9 URD 31 TT F 45 2 PC31UD69V5TF T36 6,9 URD 31 TT F Page EP.MERSEN.COM 14
15 APPENDIX Index Description 1 Page PC31UD69V55TF V37 6,9 URD 31 TT F 55 2 PC31UD69V63TF W38 6,9 URD 31 TT F 63 2 PC31UD69V7TF X39 6,9 URD 31 TT F 7 2 PC31UD69V8TF Y341 6,9 URD 31 TT F 8 2 A7UD31TTI2 A3472 A 7 URD 31 TTI 2 2 A7UD31TTI25 B3473 A 7 URD 31 TTI 25 2 A7UD31TTI315 C3474 A 7 URD 31 TTI A7UD31TTI35 D3475 A 7 URD 31 TTI 35 2 A7UD31TTI4 E3476 A 7 URD 31 TTI 4 2 A7UD31TTI45 F3477 A 7 URD 31 TTI 45 2 A7UD31TTI5 G3478 A 7 URD 31 TTI 5 2 A7UD31TTI55 H3479 A 7 URD 31 TTI 55 2 A7UD31TTI63 J348 A 7 URD 31 TTI 63 2 A7UD31TTI7 K3481 A 7 URD 31 TTI 7 2 A7UD31TTI8 L3482 A 7 URD 31 TTI 8 2 PC31UD69V16A M3322 6,9 URD 31 D8 A 16 3 PC31UD69V2A Y31 6,9 URD 31 D8 A 2 3 PC31UD69V25A Z311 6,9 URD 31 D8 A 25 3 PC31UD69V315A A312 6,9 URD 31 D8 A PC31UD69V35A Q349 6,9 URD 31 D8 A 35 3 PC31UD69V4A B313 6,9 URD 31 D8 A 4 3 PC31UD69V45A C314 6,9 URD 31 D8 A 45 3 PC31UD69V5A D315 6,9 URD 31 D8 A 5 3 PC31UD69V55A E316 6,9 URD 31 D8 A 55 3 PC31UD69V63A F317 6,9 URD 31 D8 A 63 3 PC31UD69V7A G318 6,9 URD 31 D8 A 7 3 PC31UD69V8A D346 6,9 URD 31 D8 A 8 3 PC31UD69V2D1A H319 6,9 URD 31 D11 A 2 3 PC31UD69V25D1A J32 6,9 URD 31 D11 A 25 3 PC31UD69V315D1A K321 6,9 URD 31 D11 A PC31UD69V35D1A P348 6,9 URD 31 D11 A 35 3 PC31UD69V4D1A L322 6,9 URD 31 D11 A 4 3 PC31UD69V45D1A M323 6,9 URD 31 D11 A 45 3 PC31UD69V5D1A N324 6,9 URD 31 D11 A 5 3 PC31UD69V55D1A P325 6,9 URD 31 D11 A 55 3 PC31UD69V63D1A Q326 6,9 URD 31 D11 A 63 3 PC31UD69V7D1A R327 6,9 URD 31 D11 A 7 3 PC31UD69V8D1A H379 6,9 URD 31 D11 A 8 3 A7UD31KI16 F3385 A 7 URD 31 KI 16 3 A7UD31KI2 S328 A 7 URD 31 KI 2 3 A7UD31KI25 T329 A 7 URD 31 KI 25 3 A7UD31KI315 V33 A 7 URD 31 KI A7UD31KI35 R35 A 7 URD 31 KI 35 3 A7UD31KI4 W331 A 7 URD 31 KI 4 3 A7UD31KI45 X332 A 7 URD 31 KI 45 3 A7UD31KI5 Y333 A 7 URD 31 KI 5 3 A7UD31KI55 Z334 A 7 URD 31 KI 55 3 A7UD31KI63 A335 A 7 URD 31 KI 63 3 A7UD31KI7 B336 A 7 URD 31 KI 7 3 A7UD31KI8 A317 A 7 URD 31 KI 8 3 A7UD31LI2 V3697 A7URD31LI2 4 A7UD31LI25 W3698 A 7 URD 31 LI 25 4 A7UD31LI315 X3699 A 7 URD 31 LI A7UD31LI35 Y37 A7URD31LI35 4 A7UD31LI4 Z371 A 7 URD 31 LI 4 4 EP.MERSEN.COM 15
16 Index Description 1 Page A7UD31LI45 A372 A 7 URD 31 LI 45 4 A7UD31LI5 B373 A 7 URD 31 LI 5 4 A7UD31LI55 C374 A 7 URD 31 LI 55 4 A7UD31LI63 D375 A 7 URD 31 LI 63 4 A7UD31LI7 E376 A 7 URD 31 LI 7 4 A7UD31LI8 F377 A 7 URD 31 LI 8 4 PC31UD69V16EF B ,9 URD 31 EF 16 4 PC31UD69V2EF C337 6,9 URD 31 EF 2 4 PC31UD69V25EF D338 6,9 URD 31 EF 25 4 PC31UD69V315EF E339 6,9 URD 31 EF PC31UD69V35EF N347 6,9 URD 31 EF 35 4 PC31UD69V4EF F34 6,9 URD 31 EF 4 4 PC31UD69V45EF G341 6,9 URD 31 EF 45 4 PC31UD69V5EF H342 6,9 URD 31 EF 5 4 PC31UD69V55EF J343 6,9 URD 31 EF 55 4 PC31UD69V63EF K344 6,9 URD 31 EF 63 4 PC31UD69V7EF L345 6,9 URD 31 EF 7 4 EP.MERSEN.COM 16
Protistor size 70 gr 690VAC (IEC)
Protistor size 70 gr SEMICONDUCTOR PROTECTION FUSES SQUARE BODY HIGH-SPEED FUSE-LINKS AC PROTECTION FEATURES & BENEFITS Excellent cycling capability Multiple body sizes and terminals or blades combination
More informationProtistor size 14x51 ar 690VAC (IEC) / 700VAC (UL)
690VAC (IEC) / VAC (UL) Protistor size 14x51 ar 690VAC (IEC) / VAC (UL) SEMICONDUCTOR PROTECTION FUSES IEC HIGH-SPEED CYLINDRICAL FUSE-LINKS AC PROTECTION FEATURES & BENEFITS Low l²t for improved semiconductor
More informationPSC Protection Semiconductor Square Body Fuses Now manufactured in North America for faster delivery to our North American consumers SOLUTIONS GUIDE
PSC Protection Semiconductor Square Fuses Now manufactured in North America for faster delivery to our North American consumers SOLUTIONS GUIDE PSC Square Fuses: Built with speed in mind Mersen s high-performance
More informationNH fuse-links am VAC with striker, size 0, 1, 2, 3, 4
NH fuse-links am 500-690VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions according to DIN 43 620 Parts 1 to 4 Lead free contact blades 0% cadmium APPLICATIONS am: Partial purpose,
More informationSelector guide. PSC Square body fuses Size 3X VAC End Contact Terminals. Features and Benefits
Selector guide PSC Square body fuses Size 3X 500-700VAC End Contact Terminals December 2013 Issue 2 The IXYS UK range of 700V/690V protistor fuse links provides maximum flexibility in equipment design
More informationNH fuse-links am 690VAC top indicator/live tags size 4, 4a
NH fuse-links am 69VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions according to DIN 43 62 parts 1 to 4 Non-isolated gripping lugs Double indicator Lead free contact blades %
More informationNH fuse-links gg 500VAC top indicator/live gripping-lugs size 4, 4a
LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions in accordance with DIN 43 62 Live tags Top indicator Lead free contact blades % cadmium APPLICATIONS gg: General purpose (protection
More informationProtistor size 120 gr 750VDC (IEC)
Protistor size 12 gr SEMICONDUCTOR PROTECTION FUSES SQUARE BODY HIGH-SPEED FUSE-LINKS DC PROTECTION FEATURES & BENEFITS Multiple body sizes and terminals or blades combination Very low I²t Extremely fast
More informationNH fuse-links gg 690VAC top indicator/live gripping-lugs size 4 and 4a
NH fuse-links gg 69VAC NH fuse-links gg 69VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions in accordance with DIN 43 62 Live tags Top indicator Lead free contact blades % cadmium
More informationPSC SQUARE BODY 690/700 Volt SEMICONDUCTOR PROTECTION FUSES
PSC SQUARE BOY Ferraz Shawmut 690/700V PSC fuse-links provide maximum flexibility in equipment design and ultimate protection for today s power conversion equipment. These square body fuse-links are available
More informationNH fuse-links gg 400VAC double indicator/live gripping-lugs size 000, 00, 1, 2, 3
NH fuse-links gg 4VAC double indicator/live gripping-lugs size,, 1, 2, 3 NH fuse-links gg 4VAC double indicator/live gripping-lugs size,, 1, 2, 3 LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS
More informationFuses Special Purpose
Square body 700/1300 VAC Very Fast-Acting 63 200 Amperes Description Littelfuse North American style square body semiconductor fuses provide maximum flexibility in equipment design and ultimate protection
More informationSelector guide. PSC Square body fuses Size 3X VAC Blade Terminals. Features and Benefits
Selector guide PSC Square body fuses Size X 500 700C Blade Terminals October 201 Issue 1 The IXYS UK range of 700/690 protistor fuse links provides maximum flexibility in equipment design and ultimate
More informationNH Solid Blades 690 VAC sizes 000 to 3
NH Solid Blades 6 VAC sizes 000 to gs-class Protistor NH 6 VAC fuse-links provide maximum flexibility in equipment design and ultimate protection for today s power conversion equipment. This range is a
More informationFuses for Semiconductor Protection - European Standard. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits
Fuses for Semiconductor Protection - European Standard Class: ar Voltage ratings: 660V AC to 1000V AC Current ratings: 16 A to 400 A Standards: UL 248-13 IEC 60269-1 & 4 DIN VDE 0636-40 DIN 43653 Approvals:
More informationSemiconductor (AC) fuses
Main characteristics 450 TO 700VAC / 63 TO 2800A Recognized Exceptionally low I 2 T, Watt losses. Non-magnetic construction, Highly reliable low voltage Trip-indicator system, conformity to UL, IEC, DIN
More informationNH fuse-links gg 500VAC size 000, 00, 0, 1, 2, 3
IEC LV NH fuse links with blade contacts The NH system is classified among plug-in fuse systems and is composed of: fuse-base, (possibly including terminal covers and phase barriers) fuse-link with blade
More information1250/1300 Volt PSC Square Body
Mersen 1250/1300V PSC square body fuses provide maximum flexibility in equipment design and ultimate protection for today s power conversion equipment. These square body fuses are available in four different
More informationLimitor -G General Purpose Fuses
Limitor -G General Purpose Fuses HIGH VOLTAGE IEC FUSES DIN HV GENERAL PURPOSE FUSES FOR TRANSFORMERS FEATURES & BENEFITS Mersen HV fuse-links have been used for reliable protection in high-voltage switchgear
More information690/700 Volt PSC Square Body
Mersen 690/700V PSC fuse-links provide maximum flexibility in equipment design and ultimate protection for today s power conversion equipment. These square body fuse-links are available in four different
More informationonlinecomponents.com
66 grb 66 V AC grb - from up to 3 A Size: x38 The fuse preselection table below indicates: Fuse preselection Rated current Pre-arcing I²t Total I²t at 66VAC I N (A) I²t p (A²s) I²t (A²s) - rated current
More informationSemiconductor Fuses European Fuses
66 grb 66 V AC grb - from up to 3 A Size: x38 The fuse preselection table below indicates: Fuse preselection - rated current (or ) I N - pre-arcing I²t (I²t p ) at ms - total ope I²t (I²tt) at 66 V, cos
More informationNEOZED D0 fuse-links gg 400/440VAC
NEOZED D0 fuse-links gg 400/440VAC LOW VOLTAGE IEC FUSES DIN LV FUSE-LINKS D0 FEATURES & BENEFITS The D0 fuse-system is installed in low voltage distribution units, where fuse-links are accessible to non
More informationHelioProtection HP10NH Photovoltaic fuse-links gpv 1000VDC
SPECIAL PURPOSE FUSES PHOTOVOLTAIC FUSES FEATURES & BENEFITS Mersen HP10NH photovoltaic (PV) fuse series was engineered and designed specifically for the protection of photovoltaic systems. Helio-Protection
More informationFuses for Semiconductor Protection European Standard Sizes 000 and 00. Protection of Power Semiconductors according to IEC and -4
URB Fuses for Semiconductor Protection European Standard Sizes 000 and 00 Class: ar Voltage ratings: AC 660 V AC 1000 V Current ratings: 16 A to 400 A Approvals: Standards: DIN 43653 IEC 60269-1 and -4
More informationgi-gl-gg, am gi-gl-gg gi-gl-gg NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories
,, FUSE BASES, AND ACCESSORIES Ferraz Shawmut NH Fuse-links, sizes 00, 0, 1, 2, 3 and 4 are rated 500 or 690 Volts AC with breaking capacities of 80kA or 120kA. All fuse-links include an indicator or striker
More informationSemiconductor (AC) fuses
PS ar sizes 9x - 500 V Main characteristics Ferraz Shawmut 500 V PS fuse-links provide maximum flexibility in equipment design and ultimate protection for today s power conversion equipment. These square
More informationSemiconductor (AC) fuses
Semiconductor () fuses PS ar sizes 9x - 500 V Main characteristics Ferraz Shawmut 500 V PS fuse-links provide maximum flexibility in equipment design and ultimate protection for today s power conversion
More informationHelioProtection HP15NH Photovoltaic fuse-links gpv 1500VDC
SPECIAL PURPOSE FUSES PHOTOVOLTAIC FUSES FEATURES & BENEFITS Mersen HP15NH photovoltaic (PV) fuse serie was engineered and designed specifically for the protection of photovoltaic systems. Helio-Protection
More informationHelioProtection HP15NH3L Photovoltaic fuse-links gpv 1500VDC
HelioProtection HP15NH3L SPECIAL PURPOSE FUSES PHOTOVOLTAIC FUSES FEATURES & BENEFITS Mersen HP15NH3L photovoltaic (PV) fuse series was engineered and designed specifically for the protection of photovoltaic
More informationSemiconductor (AC) fuses
x38 grb - 69VAC 69V AC grb - from up to 3 A Size: x38 The fuse preselection table below indicates: - rated current (or rating) I N - pre-arcing I 2 t (I 2 t p ) at ms - total operating I 2 t (I 2 tt) at
More informationSelect 700V/ ysuk.com. The. Current limiting. acceptance. protection of. within a single. recognised (10 38 fuses) October 2013
Select tor guide Cylindrical Fuse Links Sizes A, B & C 700V/ /690VAC, 1 100 A October 2013 Issue 1 The IXS UK range of ferrule fuse links aree fast acting fuses with superior cycling ability, available
More informationgg, am NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories NH DIMENSION KNIFE-BLADE FUSE-LINKS, FUSE BASES, AND ACCESSORIES
, am, FUSE BASES, AND ACCESSORIES Ferraz Shawmut NH Fuse-links, sizes 000, 00, 0, 1, 2, 3, 4 and 4a are rated 500 or 690 Volts AC with breaking capacities of 80kA or 120kA. All fuse-links include an indicator
More information690/700 Volt PSC Square Body
690/700 Volt PSC Square Merse 690/700V PSC square body fuses provide maximum flexibility i equipmet desig ad ultimate protectio for today s power coversio equipmet. These square body fuses are available
More informationShort Circuit. Sizes 0, 1, 2, and 690 Volt ratings - 32A through 630A All ratings include striker. 0% Lead
, am nh dimension knife-blade fuse-links, fuse bases, and accessories Ferraz Shawmut NH Fuse-links, sizes 000, 00, 0, 1, 2, 3, 4 and 4a are rated 500 or 690 Volts AC with breaking capacities of 80kA or
More informationD Type (DIAZED) FUSE-LINKS & SCREW CAP HOLDERS. EURO/IEC Fuses & Accessories 500 VOLT D TYPE DIAZED FUSE-LINKS, SCREW CAPS AND FUSE BASES
D Type (DIAZED) FUSE-LINKS & SCREW CAP HOLDERS 500 VOLT D TYPE DIAZED FUSE-LINKS, SCREW CAPS AND FUSE BASES Ferraz Shawmut D fuse-links, also called Diazed type, are 500 Volts AC rated with 75kA interrupting
More informationUltra Rapid Fuses. For Semiconductor Protection
UR Ultra Rapid Fuses For Semiconductor Protection Over many decades SIBA has developed a very comprehensive product line of Ultra Rapid fuses that has achieved worldwide acceptance. SIBA's worldwide distribution
More informationRAPIDPLUS. high speed fuse links for semiconductors
high speed fuse links for semiconductors RAPIDPLUS 2 PAGE04 ar PAGE05 gr PAGE06 gs NH ar RAPIDPLUS ar fuse links are intended to clearing short-circuits and have been designed and manufactured to have
More informationRAPIDPLUS. high speed fuse links for semiconductors
high speed fuse links for semiconductors RAPIDPLUS 2 PAGE04 ar HIGH SPEED FUSE LINKS FOR SEMICONDUCTORS PAGE05 gr HIGH SPEED FUSE LINKS FOR SEMICONDUCTORS PAGE06 gs NH HIGH SPEED FUSE LINKS FOR SEMICONDUCTORS
More informationURDC-PV. Features and Benefits FUSES. URPV Fuses for PV Semiconductor Protection. gpv. Class: Voltage ratings: 600V DC to 1500V DC.
Fuses for PV Semiconductor Protection Class: gpv 0 Voltage ratings: 600V DC to 1500V DC Current ratings: 1 A to 450 A Standards: UL 2579 IEC 60 269-6 Approvals: E341342 E341490 Features and Benefits High
More informationSwitches. Fused Switches ITCP for Semiconductor Fuses 32 to 800A CONTROL: FUSE CONNECTING: SWITCHING: MECHANISM: FIXING: CONSTRUCTION:
Fused CONTROL: Side control, padlockable in off position by three padlocks. Safe and reliable of contact position on handles. SWITCHING: Double isolation per phase. Complete isolation of fuse when circuit
More informationNH DIN Dual Indication Fuse Links
Class of Operation gl/gg, 500V AC, 10 to 630 s Sizes 000 to 3 Standards/ Approvals: Description: Packaging: IEC 60269, VDE0636, DIN 43 620 1 to 4. A square bodied range of industrial fuse links for a wide
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker
Magnetic and Hydraulic-Magnetic Circuit Breaker 845-... Description Single or multipole hydraulic-magnetic circuit breakers with trip-freemechanism and toggle actuation. A choice of switching characteristics
More informationMedium voltage fuses Medium voltage fuses
European Fuses DIN Fuses 7.2kV - 36kV IBD 7.2 UP TO 36 KV HIGH-VOLTAGE FUSES DESIGNED FOR POWER TRANSFORMER PROTECTION INTERIOR/EXTERIOR USE CERAMIC HOUSING MEDIUM CLASS TRIP-INDICATOR COMBINED WITH A
More informationBritish BS 88 Fuses. High Speed Fuses. Introduction. General Information
British BS 88 Fuses Introduction British BS 88 Contents Fuse Volts Amp Range Page 0-900 15-17 90-78-1 Accessories Indicator System & Fuse Bases British BS 88 Fuse Ranges Amps Vac Vdc -900 0 150-710 90
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker
Magnetic and Hydraulic-Magnetic Circuit Breaker 835-... Description Single or multipole hydraulic-magnetic circuit breakers with trip-free - mechanism and toggle actuation. A choice of switching characteristics
More informationAccessories. For product data sheets, visit
British BS 88 Introduction British BS 88 Contents Fuse Volts Amp Range Page 0-900 188-190 90-791-19 Accessories Indicator System & Fuse Bases 195 British BS 88 Fuse Ranges Amps Vac Vdc -900 0 150-710 90
More informationSelection Guide. HHD-BPT, DIN Style, Current-Limiting, Back-Up, Potential Transformer Protection
HHD-BPT Selection Guide HHD-BPT, DIN Style, Current-imiting,, Potential Transformer Protection Current ratings [A]; 0.5, 1, 2, 2.5, 3.15, 4, 5 E=192mm Page E=292mm Page E=367mm Page E=442mm Page E=537mm
More informationMULTIBLOC 000.ST8 Size 000, 100A, 690VAC, Design for Bottom Fitting, Triple Pole
MULTIBLOC 000.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR FEATURES & BENEFITS The production programme of MULTIBLOC 000.ST8 comprises NH fuse switch disconnectors for 100A. They are designed
More information半导体保护快速熔断器 (Flush End Contact) Fuses for Semiconductor Protection
半导体保护快速熔断器 (Flush End Contact) European Standard Standard :IEC269.4 Kaiert is a company which designs,manufactures,sells and markets electric materials and has a wide range of product available to cover
More informationNH fuse-links gtr 400VAC top indicator/live gripping-lugs size 2, 3, 4a
NH fuse-links gtr 400VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS The NH system is classified among plug-in fuse systems and is composed of: fuse-base, (possibly including terminal covers
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker
Magnetic and Hydraulic-Magnetic Circuit Breaker 835-... Description Single or multipole hydraulic-magnetic circuit breakers with trip-free - mechanism and toggle actuation. A choice of switching characteristics
More informationRX 3 MCB 4500 A Phase + Neutral, neutral on left side
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 RX 3 MCB 4500 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationCL-14 SERIES E-RATED / MEDIUM VOLTAGE FUSES
SERIES E-RATED / MEDIUM VOLTAGE FUSES 5kV AND 15kV CLIP-LOCK MOUNTED FUSES Amp-trap E-rated 5kV and 15kV fuses have 3" diameter barrels and mount in unique cam-locking clips, for superior connections as
More informationBETA Switching Switches and Light Indicators
Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET
More informationBussmann series NH catalogue. Leadership in circuit protection
Bussmann series NH catalogue Leadership in circuit protection Energizing a world that demands more. We deliver: Electrical solutions that use less energy, improve power reliability and make the places
More informationMEDIUM VOLTAGE FUSES FOR CAPACITORS NORTH AMERICAN STYLE
SIBA Products are available from: MARYLAND METRICS phones: (410)358-3130 (800)638-1830 faxes: (410)358-3142 (800)872-9329 URL: http://mdmetric.com E-mail: sales@mdmetric.com P.O.Box 261 Owings Mills, MD
More informationHHB. Medium Voltage Fuses British Standard. Introduction. Fuse-links for oil insulated switchgear
HHB Medium Voltage Fuses British Standard For Oil Insulated Switchgears Introduction Medium voltage fuse-links according to British Standard are back-up fuse-links for the protection of substations up
More informationTMC 91H is now TMC 60 C Series
TMC 91H is now TMC 60 C Series The new Thermal Magnetic Circuit Breaker is once again available and better than ever! The new version is not only UL recognized with the same electrical performance as the
More informationHIGH-SPEED SEMICONDUCTOR FUSES CATALOG POWR-SPEED PRODUCTS HIGH-SPEED FUSES FUSE BLOCKS & HOLDERS
HIGH-SPEED SEMICONDUCTOR FUSES CATALOG POWR-SPEED PRODUCTS HIGH-SPEED FUSES FUSE BLOCKS & HOLDERS MICROSWITCHES FAST-ACTING FUSES NEW PSR Series High-Speed Square-Body Fuses Now available in case sizes
More informationNH DIN Dual Indication Fuse Links Class am, 690Vac, 6 to 500 Amps, Sizes 000 to 3 NH Series
Description: A range of Class am square bodied industrial fuse links for a wide variety of motor protection applications. Packaging: MOQ: 3 Catalogue Symbol: Class of Operation: (amp)nhm(size)b-690 am
More informationLow-Peak 600V Class RK1
LPS-RK 600Vac/300Vdc, 1 10-60A, Dual Element, Time-Delay Fuses Dimensions - in 5" (± 0.31) 5.5" (± 0.31) Available with easyid open fuse indication 1/10 to 30A 0.81" (±0.008) 35 to 60A 1.06" (±0.008) Description:
More informationPhase + Neutral, neutral on left side
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1
More information, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX 3 4500 A / 6 ka CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1
More informationLENRK/LESRK CLASS RK1 DUAL ELEMENT TIME-DELAY FUSES
LENRK/LESRK CLASS RK Catalog Number LENRK (. - 0A) 50 Volts AC or Less Catalog Number LESRK (.5-0A) 0 Volts AC or Less S LENRK 50V 0..5 75 0..5 5 0..5 9 50 5 0.5 50 0.. 70 0 0..5 5 0 50 7.5 90 0..5 0 50.
More information1489-M Circuit Breakers
Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Terminal design helps prevent wiring misses Scratch- and solventresistant printing Suitable
More informationModulostar CMS10 Modular fuse-holders
Modulostar CMS10 FUSE HOLDERS, FUSE BASES AND SUPPORTS IEC CYLINDRICAL FUSE HOLDERS FEATURES & BENEFITS The innovative and comprehensive Modulostar range of Mersen fuse-holders. are finger-safe under IEC
More informationUltraSafe US22 Modular fuse-holders
UltraSafe US22 FUSE HOLDERS, FUSE BASES AND SUPPORTS UL/CSA FUSE HOLDERS FEATURES & BENEFITS The innovative and comprehensive UltraSafe range of Mersen fuse-holders. are finger-safe under IEC standards
More information25.4. Molded Case Circuit Breakers. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents
.4 Molded Case Circuit Breakers Gi-, Fi, Ji-, Ki-, Li-Frames Molded Case Circuit Breaker Family Molded Case Circuit Breakers When higher interrupting ratings are not required. Product Overview Gi-, Fi,
More informationDNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation
More informationControls HIGH SPEED FUSES
Controls HIGH SPEED FUSES 0800 367 934 High Speed Fuses HIGH SPEED FUSES Summary High Speed Fuses 4 Time vs. Current Curves 7 Current limitation curves 11 High Speed Fuses 15 Accessories 17 Dimensions
More informationPOWR-SPEED FUSES TECHNICAL APPLICATIONS GUIDE
POWR-SPEED FUSES TECHNICAL APPLICATIONS GUIDE TABLE OF CONTENTS 1.0 INTRODUCTION... 3 2.0 POWER SEMICONDUCTOR DEVICES... 4 2.1 Power Semiconductor Device Classification... 4 3.0 OVERCURRENT PROTECTION
More informationFuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A
DISTRIBUTION SOLUTIONS Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A Superior performance versus standard fuses ensuring up to 40% faster protection in case of low
More informationFMotor Circuit Controllers
Technical Information Motor Circuit Controller IEC Performance Data Catalog Number KTA7-25S...32S 0.16A 0.25A 0.4A 0.63A 1A 1.6A 2.5A 4A 6.3A 10A 16A 20A 25A 29A 32A Rated Operational Current, I e [A]
More informationPhase + Neutral, neutral on right side
87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX 3 MCB 6000 A / 10 ka Cat.. N (s): 4 074 67 / 68 / 69 / 70 / 71 / 72 / 73 / 74 / 75 / 76 / 77 / 78 / 79 ; 4 077 33 / 34
More informationPD-Series Ground Fault Circuit Protection
PD-Series Ground Fault Circuit Protection SmartGuard is an equipment ground fault protection device that functions as a standard high-quality Carling hydraulic/ magnetic circuit breaker, offering customized
More informationHigh voltage current limiting Fuse links type CEF
High voltage current limiting Fuse links type CEF Index 1. General........................................... 9 2. Overvoltages...................................... 9 3. Pre-arcing times and cut-off characteristics..............
More informationCS-3 SERIES E-RATED/MEDIUM VOLTAGE FUSES
SERIES E-RATED/MEDIUM VOLTAGE FUSES 5kV, 8kV and 15.5kV FERRULE MOUNTED FUSES Amp-trap E-rated 5kV 8kV and 15kV fuses have 2 or 3 inch diameter barrels with ferrules and are mounted in spring reinforced
More informationLPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse
LPSRK100SP 600V TD Dual Elem Class RK1 Low Peak Fuse Catalog Number Manufacturer Description Weight per unit Product Category LPSRK100SP 600V Class RK1 Low Peak Dual Element, Time Delay Fuse 0.4100 (lbs/each)
More informationLPCC3 3A 600V TD Class CC Low Peak Fuse. Features amperage rating. Dimensions and Weight. Long Description. Manufacturer Information
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-794 Fax: 936-560-4685 LPCC3 3A 600V TD Class CC Low Peak Fuse Catalog Number Manufacturer Description Weight per unit Product Category LPCC3
More informationHigh Speed Fuses. Section Contents Page
Section Contents Page General pplications.......................1-13 North merican fuses & accessories...........1-11 DFJ - High speed Class J fuse.................. 15 Square ody fuses & accessories............
More information3 - Protection components Motor circuit-breakers
Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page
More informationSynergy EN product information
Synergy EN60947-4-2 product information Rated operational voltages U e 200Vac to 480Vac Rated operational currents I e See Rating Table Rating index See Sizing Guide Rated frequency/frequencies 50-60Hz
More informationfuses fuse holders CYLINDRICAL
fuses fuse holders 02 gg FUSES 04 am FUSES FUSES 09 PMC COMPACT 09 -CC FOR CC CLASS FUSE-LINKS 11 PMB PLUG CONNECTION 11 CLIP CONTACT FOR φ10 FUSE-LINKS 10 PMF 11 BAC OPEN FUSE BASES 06 gg FUSES FUSES
More informationMULTIFIX 60 Universal Bus Bar Carriers
MULTIFIX MULTIFIX BUS BAR SYSTEMS COMPONENTS FOR MM SYSTEMS FEATURES & BENEFITS MULTIFIX is a system for energy distribution comprising a variety of modular combinable components. The energy distribution
More informationFusegear for Semiconductor Fuse
Fusegear for Semiconductor Fuse IP 20.SI Bases for PSC ranges: SI TT, SI 000/00, SI DIN SI TT for stud-type fuses SI 00 for bracket-type fuses STANDARD VERSION SI FUSEHOLDERS FOR STUD-TYPE FUSES, FOR BLADE-TYPE
More informationApplications. Distribution transformers up to 2000 kva High-voltage motors up to 3 MW Capacitors up to1200 kvar MV voltage transformers Cable feeders
Applications HV HRC (high-voltage high rupturing capacity) fuses are used for short circuit protection in high-voltage switchgear for the 50 to 60 Hz frequency range Distribution transformers up to 2000
More informationHigh reliability against cyclic and peak current loads / age resistant due to high motor start up currents
HHM High Voltage Fuses Motor Circuit Protection DIN and British Standard SIBA Motor Rated Fuses are available in - German DIN Standard and - British Standard Design The large variety in body sizes / mounting
More informationMiniature Circuit Breakers
S00 Series Miniature S00 Series Miniature Circuit Breakers Description The S00 Series miniature circuit breaker offers a compact solution for protection requirements. The S00 devices are UL tested limiting
More informationDRX 250 B/N/H Circuit breaker (not adjustable)
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 References rences: /18/19/20/21/22/23/24/25/26/27/28/29/ 32/33 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. MOUNTING 2 5.
More informationChange-over Disconnectors HUVS Range 36kV (630 to 6300Amp)
Changeover switches 7.2kV to 40.5kV For more than 100 years, Mersen has been providing the market with safe, reliable and longer life time off-load disconnectors. These devices offer high performances
More informationFUSES FOR SEMICONDUCTORS
FUSES FOR SEMICONDUCTORS. POWER SEMICONDUCTORS.. Three families of power semiconductors.. Power semiconductors history.3. Current conversion: one application of the power semiconductors.4. Power semiconductors
More informationSemiconductor Fuses Microswitches & Studs
MICROSWITCH SYSTEMS ADAPTED TO THE FOLLOWING FUSES: - PSC sizes 0,,, / 70, 7, 7, 7 - Blade-type PSC (PA) sizes 0-, - / 70, 7, 7, 7 - PSC sizes 000 / 00 New MS L -5 B6 MS PA -5 HIGHLY RESISTANT STUDS OFFERING
More informationLINOCUR Size D02 63A 230VAC/440VAC
IEC FUSE SWITCH DISCONNECTORS D0 FUSE COMBINATION UNITS The D0 Linocur is a combination of switch disconnector fuse and Neozed 63A fuse-link, equiped with significant safety characeristics and sophisticated
More information24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)
.4 Miniature Circuit Breakers and Supplementary Protectors SPHM Supplementary Protector SPHM Supplementary Protector Product Description The SPHM Supplementary Protector is a dual rated product for both
More informationMEDIUM VOLTAGE DIN Fuse-Links
Standards/Approvals: DIN 43625, VDE 0670 part 4, VDE 0670 part 402 and IEC 60282-1 (2005) Catalogue Symbol: 24TDMEJ(amp) 24THMEJ(amp) 24TFMEJ(amp) 24TXMEJ(amp) Class of Operation: Back-up as IEC 60282-1
More informationCL-14 SERIES E-RATED / MEDIUM VOLTAGE FUSES
SRIS -RATD / MDIUM VOLTAG FUSS 5kV AND 15kV CLIP-LOCK MOUNTD FUSS Amp-trap -rated 5kV and 15kV fuses have 3" diameter barrels and mount in unique cam-locking clips, for superior connections as well as
More informationPowerLine OS Switch Fuses A, 690V
Technical Brochure PowerLine OS Switch Fuses 20...160 A, 690V Brochure OS 10 GB 99-04 9902CD04 ABB Control New Switch Fuse Range 2 3 Total user safety Total user safety Fuse carriers fully IP20 protected
More informationThermal Overcurrent Circuit Breaker 3120-F...
Thermal Overcurrent Circuit Breaker 0-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (S-type TO CBE to EN 6094 with trip free mechanism) offering the choice of
More informationHigh-voltage high-breaking capacity VV fuse-links
High- high- VV fuse-links imum cold resistance power dissipation pre-arcing I t value total I t value [kv] (mm) I n [A] (ka) [mω] [W] [A s] [A s] 1 580,1 57 A 0 370 9 17,3 1 A 5 00 10 3 30 10 A 55 7 11
More information