flowmeters Section Guide

Similar documents
digital flow meters BW Digi-Meter F-1000

F300 - PITOT TUBE ACRYLIC FLOWMETERS

DIGIFLO ELECTRONIC FLOWMETER

Corrosion Resistant and Ultra-Pure Rotameters for Accurate Measurement of Liquids and Gases

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading.

Flowmeter DFM

Praher S4 Ball Valve. manual valves. Materials. Sizes. Pressure Rating. Features. Connections. Valve Dimensions. Actuation.

Praher S4 Ball Valve. manual valves. Materials. Sizes. Pressure Rating. Features. Connections. Valve Dimensions. Actuation.

Plastic tube variable area flowmeter for liquids and gases

Thermoplastic. Order Online. Specialists in. Since Piping systems. fwwebb.com/plastics Flowmeters & Process Control.

F-2000 MODEL RT INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

standard and industrial pipe fittings

pvc-u section guide application guide standards and approvals

INSTALLATION AND OPERATION

RCM - Direct Reading Flowmeters

Technical Data. Flow Meter Schwertberg, Poneggenstr. 5 Austria/Europe Fax +43/7262/ Tel.

2100 Turbine Flow Sensor

macnaught flow measurement

Pressure relief valve DHV 718

Flow Meters & Instruments. Insertion Paddle Wheel & Magnetic Flow Meters Flow & Anaytical Instruments. Technical Catalogue

flow x3 flow monitoring

KM-165, KM-185, KM-200 OVERVIEW. Flow Monitor & Flow Indicator. Features. Operation

macnaught flow measurement

pvc-c manual valves inch sizes manual valves inch sizes Spears True Union 2000 Industrial Ball Valve

INSERTION flowmeter with paddle wheel, ELEMENT design

Positive displacement flowmeter for continuous flow measurement

Variable area flowmeter DFM 165 to 350

EZ-View Flow Meters. With Flow-Alert TM Flow Switch REDUCE MAINTENANCE COSTS TEL

PSF50 Paddle flow switch

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

industrial and economy pipe fittings PVC-U Solvent Cement WELD-ON REGULAR 719 Size Code Price 500ml tin

Flowmeters & Monitors

Insertion turbine INSTRUCTION SHEET. TECHNICAL PRODUCT

macnaught flow measurement

INSERTION Adaptor for analysis

OM SERIES OVAL GEAR METERS. OM SERIES Oval Gear Meters

King Instrument Company opened its doors in 1983 with one major goal:

Metal tube variable area flowmeter for gases, liquids and steam

Flowmeter, Plastic 805 / 807 / 815 / / 825 / 832 / 835. Sectional drawing

Paddle-wheel flow controller for On/Off control

RCM. Direct Reading Flowmeter. for Liquids or Gases

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

OM004, OM006 & OM008 Oval Gear Meter

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

INSERTION flow sensor for continuous flow measurement

QUALITY INDUSTRIAL FLOWMETERS

Insertion magnetic inductive flowmeter

Flow switches Series AD/VH

EZ-View Flow Meters. General Design Features OPERATING PRINCIPLE

Paddle-wheel flow controller for On/Off control

EZ-View. Flow Meters ISO CERTIFIED 9001

Low Profile Insertion Vortex

Magnetic Paddle Flow Sensor/Switch for Easy On/Off Control

CATALOG. Actuated Diaphragm Valve DN PVC-U / PVC-C / PP-H / PVDF / ABS SMART IN FLOW CONTROL.

Distributed by: M&M Control Service, Inc MICRO-FLO MICRO-FLO

Plastic Flow Meters for gases & liquids, using TROGAMID* & POLYSULFONE Technology

/ 855 / 857 / 861 / / 870 / 875 / 880 / 885. Variable Area Flowmeter, Plastic

Variable Area Flowmeters Ori-Flowrator TM Meters

Positive displacement flowmeter

double containment section guide application guide

Orifice plate flowmeters Series PR By-pass flowmeter for liquids, gases and steam

Inductive conductivity meter

Model FVP General Specification. Flanged Vortex Plate. Product Features

SIGNET Vortex Flow Sensors ENGLISH

Diaphragm Valve, Plastic

Flowmeter, Plastic 855 / 857 / 865 / / 875 / 880 / 885

BFS-10-O G1/4: BFS-10-O G1/2: BFS-10-O G1: Contact rating: BFS-10-O G1/4

MX-SERIES OVAL GEAR FLOW METERS

Pipe Nipples / Solvent Cement / Pipe Clips 11. Diaphragm Valves / Knife Gate Valves 21

KDM ARMORED FLOW METER & SWITCH

Digital ph transmitter

Variable Area Flow Meters

485 - NC NO/DA DN

Paddle-wheel flow controller with optical principle for On/Off control

Hot Tap Insertion Vortex

Signet 7000/7001 Vortex Flow Sensors * *

Operating Manual Model- P282 Digiflow Controller

UNIVERSAL. Flow Monitors Inc. INSITE Series PX - IS - TX Flow Rate Indicators and Switches

G2 Industrial Grade Meters

Operating Instructions for Plastic Flow Meter. Model: KSK

Rotameters Rotameters

BI-DIRECTIONAL INSERTION FLOW TRANSDUCER

Praher S4 Ball Valve. manual valves. Praher Type S4 Ball Valve. Materials. Size. Pressure Rating. Features. Connections.

RUN ACCUM. TOTAL STOP BAT LOW HIGH

abs section guide application guide standards and approvals

FLOWMETERS PRODUCT OVERVIEW

KOBOLD KSK FLOWMETER. User Instructions

ProMinent Beta Solenoid Diaphragm Metering Pumps

PNEUMATICALLY ACTUATED 2-WAY

Diaphragm Valve, Plastic 2/2 way, motorized

Flowmeters with Float. Flow Measurement of Gases & Clear Liquids with Float Series 6001 & Series 6001/ Measurement Principle.

Inductive conductivity meter

DPT TARGET TYPE FLOWMETERS

Vortex Plate. Model VP General Specification. Product Features

Model FM1000 Series Operating Instructions. Drum Pump Flow Meter

ProSeries NEMA 4X SONIC-PRO. Engineering and Technical Data. Transit Time Ultrasonic Flowmeter. Industries, Ltd. s Ultrasonic Flow Meters

2/2-way Quarter-Turn Ball Valve in stainless steel with pneumatic rotary actuator, DN 10-50

Positive displacement batch controller

Industrial OG meter series IOG Inline and flanged oval gear meter

QUALITY INDUSTRIAL FLOWMETERS

Transcription:

flowmeters Increasing levels of automation in process systems inevitably requires the greater use of equipment to accurately measure and subsequently control flow, ph, ORP (Redox), conductivity, temperature or pressure. Of key importance is the need to have equipment which is simple to operate, easy to maintain, and provide reliable measurement results. Suitable for use with water, aqueous or aggressive liquids (and gases), our range of flow measurement products are designed to fulfil a wide range of applications, from simple visible indication using variable area flow meters, to the sophisticated analytical controls used typically in chemical dosing or water and waste water treatment. Section Guide meters and Sensors ASV Stubbe Variable Area meters 464 BlueWhite Variable Area meters 472 BlueWhite Digital meters 480 X3 Monitoring 486 The choice of equipment is wide and requires careful consideration. Our Customer Services Team are trained to assist with the selection of the correct products, but to help us give the best advice, please copy and complete the enquiry sheet, so that we get a complete understanding of your requirements. IPS Systems Seaham Grange Industrial Estate, Seaham, Co Durham, SR7 0PT, England Tel: +44+ 191 521 3111 Fax: +44+ 191 521 3222 Email: sales@ipsflowsystems.com Website: www.ipsflowsystems.com

The ASV Stubbe variable area flowmeter uses a precision moulded transparent tube with a tapered bore, into which is fitted a conical weighted float. The media (water, air, liquid or gaseous chemicals) flows vertically from the bottom to the top. As it passes through the tube, it displaces the float and raises it to a point where equilibrium is established between the lifting force of the media and the weight of the float. The top edge of the float directly indicates the flow volume on the graduated tube scale. Materials for most media: PVCU, Polyamide (PA), Polysulfone (PSU) and PVDF Float manufactured from PVDF or Stainless Steel Optional magnetic float for use with limit switches Piping connections to PVCU, Polypropylene and PVDF (ABS available on request) Two visible scales on each meter: flow rate and percentage (DFM 335 and DFM 350 only) Standard scales in L/hr, optional m 3 /hr or GPM ASV Stubbe meter Programme Overview Measuring DN Series DFM Range 1) l/hr MM Inch 165 170 185 200 335 350 324 10 560 10 10100 10 25250 10 550 15 1 / 2" 15150 15 1 / 2" 25250 15 1 / 2" 40400 15 1 / 2" 15150 20 3 / 4" 40400 20 3 / 4" 60600 20 3 / 4" 1001000 20 3 / 4" 15150 25 1" 25250 25 1" 30300 25 1" 40400 25 1" 60600 25 1" 1001000 25 1" 1501500 25 1" 1501500 32 1 1 /4" 2502500 32 1 1 /4" 2002000 40 1 1 /2" 3003000 40 1 1 /2" 4004000 50 2" 6006000 50 2" 100010000 50 2" 150015000 63 2 1 /2" 250025000 63 2 1 /2" 1000050000 63 2 1 /2" 1) With water at 20 C 464

VAFM Limit Switch Functions Monostable open ZE 950 (48448) Monostable Limit Switch closed open Closed when Float is level with switch. Any movement up or down opens switch again. BiStable closed open ZE 951 (48119) BiStable Limit Switch Normally Open closed ZE 951 (113131) BiStable Limit Switch Normally Closed open open closed Switch closes as float moves up from below or is level with switch. As float moves up, switch stays closed. Only when moving down below the switch will it open again. Switch opens as float moves up from below or is level with switch. As float moves up, switch stays open. Only when moving down below the switch will it close again. 465

ASV Stubbe DFM 165 meter Description: Inline variable area flowmeter Mounting: Vertical flow upwards Maximum Fluid Pressure at 20 C: 10 bar Maximum Fluid Temperature: PVCU: 60 C PA: 75 C PSU: 100 C Accuracy: ±2.5% full scale Scaling: L/hr H 2 O standard plus 0100% max flow. Special scales (on request): Air; US GPM; Na0H; FeCI Length: 165mm PVCU MM Solvent Socket Connections Range l/h Dia. mm 324 16 560 16 10100 16 25250 16 PVCU Tube Polyamid Tube Polysulfone Tube 475002 88.88 476832 140.61 475012 88.88 476842 140.61 475022 88.88 476852 140.61 475032 88.88 476862 140.61 475162 93.57 476992 145.57 475172 93.57 477002 145.57 475182 93.57 477012 145.57 475192 93.57 477022 145.57 475322 98.55 477152 150.23 475332 98.55 477162 150.23 475342 98.55 477172 150.23 475352 98.55 477182 150.23 Polypropylene Fusion Socket Connections Range l/h Dia. mm 324 16 560 16 10100 16 25250 16 PVCU Tube Polyamid Tube Polysulfone Tube 475003 120.31 476833 172.28 475013 120.31 476843 172.28 475023 120.31 476853 172.28 475033 120.31 476863 172.28 475163 124.97 476993 177.15 475173 124.97 477003 177.15 475183 124.97 477013 177.15 475193 124.97 477023 177.15 475323 129.96 477153 181.97 475333 129.96 477163 181.97 475343 129.96 477173 181.97 475353 129.96 477183 181.97 PVDF Fusion Socket Connections Range l/h Dia. mm 324 16 560 16 10100 16 25250 16 PVDF Tube Polyamid Tube Polysulfone Tube 141960 239.94 141964 285.02 141961 239.94 141965 285.02 141962 239.94 141966 285.02 141963 239.94 141967 285.02 475164 156.70 476994 209.34 475174 156.70 477004 209.34 475184 156.70 477014 209.34 475194 156.70 477024 209.34 475324 161.84 477154 213.39 475334 161.84 477164 213.39 475344 161.84 477174 213.39 475354 161.84 477184 213.39 Construction: Tube Materials: PVCU, PVDF, Polyamid (PA) or Polysulfone (PSU) End Connections: PVCU Socket or Spigot Ends Polypropylene or PVDF Sockets Float: Fully encapsulated PVDF Float Stops: PVDF ORings: EPDM (FPM option on request) Options and Spares: Limit Reed Switch: ZE 950 (Monostable): Normally Open 48118 76.19 ZE 951 (Bistable): Normally Open 48119 101.45 Normally Closed 113131 101.45 Limit Value Switch (use with ZE 950): ZE 3060 24V DC 136244 279.66 230V AC 136245 303.06 Contact Protective Relay (use with ZE 950 or ZE 951): ZE 3061 24V DC 136239 332.99 230V AC 136240 259.20 Data Sensor: ZE 3000 (2 wire)* 137251 793.94 * meter size and flow rate to be advised at time of order Special Scales: Air; US GPM; HCI; Na0H; FeCI on application 26.10 466

ASV Stubbe DFM 170 meter Description: Inline variable area flowmeter Mounting: Vertical flow upwards Maximum Fluid Pressure at 20 C: 10 bar Maximum Fluid Temperature: PVCU: 60 C PA: 75 C PSU: 100 C Accuracy: ±2.5% full scale Scaling: L/hr H 2 O standard plus 0100% max flow. Special scales (on request): Air; US GPM; Na0H; FeCI Length: 170mm PVCU Inch Solvent Socket Connections PVCU Tube Polyamid Tube Polysulfone Tube Range Dia. l/h inch 550 1 /2 475041 93.57 476871 145.57 475201 98.55 477031 150.23 475361 104.36 477191 156.20 15150 1 /2 475051 93.57 476881 145.57 475211 98.55 477041 150.23 475371 104.36 477201 156.20 25250 1 /2 475061 93.57 476891 145.57 475221 98.55 477051 150.23 475381 104.36 477211 156.20 40400 1 /2 475071 93.57 476901 145.57 475231 98.55 477061 150.23 475391 104.36 477221 156.20 PVCU MM Solvent Socket Connections PVCU Tube Polyamid Tube Polysulfone Tube Range Dia. l/h mm 550 20 475042 93.57 476872 145.57 475202 98.55 477032 150.23 475362 104.36 477192 156.20 15150 20 475052 93.57 476882 145.57 475212 98.55 477042 150.23 475372 104.36 477202 156.20 25250 20 475062 93.57 476892 145.57 475222 98.55 477052 150.23 475382 104.36 477212 156.20 40400 20 475072 93.57 476902 145.57 475232 98.55 477062 150.23 475392 104.36 477222 156.20 Polypropylene Fusion Socket Connections PVCU Tube Polyamid Tube Polysulfone Tube Range Dia. l/h mm 550 20 475043 128.84 476873 181.18 475203 133.81 477033 186.00 475363 139.61 477193 191.63 15150 20 475053 128.84 476883 181.18 475213 133.81 477043 186.00 475373 139.61 477203 191.63 25250 20 475063 128.84 476893 181.18 475223 133.81 477053 186.00 475383 139.61 477213 191.63 40400 20 475073 128.84 476903 181.18 475233 133.81 477063 186.00 475393 139.61 477223 191.63 PVDF Fusion Socket Connections PVDF Tube Polyamid Tube Polysulfone Tube Range Dia. l/h mm 550 20 141968 253.64 141972 297.90 475204 164.25 477034 216.58 475364 170.69 477194 222.23 15150 20 141969 253.64 141973 297.90 475214 164.25 477044 216.58 475374 170.69 477204 222.23 25250 20 141970 253.64 141974 297.90 475224 164.25 477054 216.58 475384 170.69 477214 222.23 40400 20 141971 253.64 141975 297.90 475234 164.25 477064 216.58 475394 170.69 477224 222.23 Construction: Tube Materials: PVCU, PVDF, Polyamid (PA) or Polysulfone (PSU) End Connections: PVCU Socket or Spigot Ends Polypropylene or PVDF Sockets Float: Fully encapsulated PVDF Float Stops: PVDF ORings: EPDM (FPM option on request) Options and Spares: Limit Reed Switch: ZE 950 (Monostable): Normally Open 48118 76.19 ZE 951 (Bistable): Normally Open 48119 101.45 Normally Closed 113131 101.45 Limit Value Switch (use with ZE 950): ZE 3060 24V DC 136244 279.66 230V AC 136245 303.06 Contact Protective Relay (use with ZE 950 or ZE 951): ZE 3061 24V DC 136239 332.99 230V AC 136240 259.20 Data Sensor: ZE 3000 (2 wire)* 137251 793.94 * meter size and flow rate to be advised at time of order Special Scales: Air; US GPM; HCI; Na0H; FeCI on application 26.10 467

ASV Stubbe DFM 185 meter Description: Inline variable area flowmeter Mounting: Vertical flow upwards Maximum Fluid Pressure at 20 C: 10 bar Maximum Fluid Temperature: PVCU: 60 C PA: 75 C PSU: 100 C Accuracy: ±2.5% full scale Scaling: L/hr H 2 O standard plus 0100% max flow. Special scales (on request): Air; US GPM; Na0H; FeCI Length: 185mm PVCU Inch Solvent Socket Connections PVCU Tube Polyamid Tube Polysulfone Tube Range Dia. l/h inch 15150 3 /4 475081 98.55 476911 150.23 475241 104.36 477071 156.20 475401 114.18 477231 165.86 40400 3 /4 475091 98.55 476921 150.23 475251 104.36 477081 156.20 475411 114.18 477241 165.86 60600 3 /4 475101 98.55 476931 150.23 475261 104.36 477091 156.20 475421 114.18 477251 165.86 1001000 3 /4 475111 98.55 476941 150.23 475271 104.36 477101 156.20 475431 114.18 477261 165.86 PVCU MM Solvent Socket Connections PVCU Tube Polyamid Tube Polysulfone Tube Range Dia. l/h mm 15150 25 475082 98.55 476912 150.23 475242 104.36 477072 156.20 475402 114.18 477232 165.86 40400 25 475092 98.55 476922 150.23 475252 104.36 477082 156.20 475412 114.18 477242 165.86 60600 25 475102 98.55 476932 150.23 475262 104.36 477092 156.20 475422 114.18 477252 165.86 1001000 25 475112 98.55 476942 150.23 475272 104.36 477102 156.20 475432 114.18 477262 165.86 Polypropylene Fusion Socket Connections PVCU Tube Polyamid Tube Polysulfone Tube Range Dia. l/h mm 15150 25 475083 136.23 476913 188.40 475243 142.03 477073 194.04 475403 151.86 477233 203.71 40400 25 475093 136.23 476923 188.40 475253 142.03 477083 194.04 475413 151.86 477243 203.71 60600 25 475103 136.23 476933 188.40 475263 142.03 477093 194.04 475423 151.86 477253 203.71 1001000 25 475113 136.23 476943 188.40 475273 142.03 477103 194.04 475433 151.86 477263 203.71 PVDF Fusion Socket Connections PVDF Tube Polyamid Tube Polysulfone Tube Range Dia. l/h mm 15150 25 141976 267.30 141980 310.81 475244 181.18 477074 233.49 475404 191.63 477234 243.16 40400 25 141977 267.30 141981 310.81 475254 181.18 477084 233.49 475414 191.63 477244 243.16 60600 25 141978 267.30 141982 310.81 475264 181.18 477094 233.49 475424 191.63 477254 243.16 1001000 25 141979 267.30 141983 310.81 475274 181.18 477104 233.49 475434 191.63 477264 243.16 Construction: Tube Materials: PVCU, PVDF, Polyamid (PA) or Polysulfone (PSU) End Connections: PVCU Socket or Spigot Ends Polypropylene or PVDF Sockets Float: Fully encapsulated PVDF Float Stops: PVDF ORings: EPDM (FPM option on request) Options and Spares: Limit Reed Switch: ZE 950 (Monostable): Normally Open 48118 76.19 ZE 951 (Bistable): Normally Open 48119 101.45 Normally Closed 113131 101.45 Limit Value Switch (use with ZE 950): ZE 3060 24V DC 136244 279.66 230V AC 136245 303.06 Contact Protective Relay (use with ZE 950 or ZE 951): ZE 3061 24V DC 136239 332.99 230V AC 136240 259.20 Data Sensor: ZE 3000 (2 wire)* 137251 793.94 * meter size and flow rate to be advised at time of order Special Scales: Air; US GPM; HCI; Na0H; FeCI on application 26.10 468

ASV Stubbe DFM 200 meter Description: Inline variable area flowmeter Mounting: Vertical flow upwards Maximum Fluid Pressure at 20 C: 10 bar Maximum Fluid Temperature: PVCU: 60 C PA: 75 C PSU: 100 C Accuracy: ±2.5% full scale Scaling: L/hr H 2 O standard plus 0100% max flow. Special scales (on request): Air; US GPM; Na0H; FeCI Length: 200mm PVCU Inch Solvent Socket Connections PVCU Tube Polyamid Tube Polysulfone Tube Range Dia. l/h inch 25250 1 475121 109.35 476951 160.90 475281 114.18 477111 165.86 475441 124.97 477271 177.15 40400 1 475131 109.35 476961 160.90 475291 114.18 477121 165.86 475451 124.97 477281 177.15 1001000 1 475141 109.35 476971 160.90 475301 114.18 477131 165.86 475461 124.97 477291 177.15 1501500 1 475151 109.35 476981 160.90 475311 114.18 477141 165.86 475471 124.97 477301 177.15 PVCU MM Solvent Socket Connections PVCU Tube Polyamid Tube Polysulfone Tube Range Dia. l/h mm 25250 32 475122 109.35 476952 160.90 475282 114.18 477112 165.86 475442 124.97 477272 177.15 40400 32 475132 109.35 476962 160.90 475292 114.18 477122 165.86 475452 124.97 477282 177.15 1001000 32 475142 109.35 476972 160.90 475302 114.18 477132 165.86 475462 124.97 477292 177.15 1501500 32 475152 109.35 476982 160.90 475312 114.18 477142 165.86 475472 124.97 477302 177.15 Polypropylene Fusion Socket Connections PVCU Tube Polyamid Tube Polysulfone Tube Range Dia. l/h mm 25250 32 475123 152.33 476953 204.48 475283 157.17 477113 209.34 475443 168.28 477273 219.81 40400 32 475133 152.33 476963 204.48 475293 157.17 477123 209.34 475453 168.28 477283 219.81 1001000 32 475143 152.33 476973 204.48 475303 157.17 477133 209.34 475463 168.28 477293 219.81 1501500 32 475153 152.33 476983 204.48 475313 157.17 477143 209.34 475473 168.28 477303 219.81 PVDF Fusion Socket Connections PVDF Tube Polyamid Tube Polysulfone Tube Range Dia. l/h mm 25250 32 141984 293.90 141988 337.37 475284 212.34 477114 265.70 475444 244.65 477274 276.15 40400 32 141985 293.90 141989 337.37 475294 212.34 477124 265.70 475454 244.65 477284 276.15 1001000 32 141986 293.90 141990 337.37 475304 212.34 477134 265.70 475464 244.65 477294 276.15 1501500 32 141987 293.90 141991 337.37 475314 212.34 477144 265.70 475474 244.65 477304 276.15 Construction: Tube Materials: PVCU, PVDF, Polyamid (PA) or Polysulfone (PSU) End Connections: PVCU Socket or Spigot Ends Polypropylene or PVDF Sockets Float: Fully encapsulated PVDF Float Stops: PVDF ORings: EPDM (FPM option on request) Options and Spares: Limit Reed Switch: ZE 950 (Monostable): Normally Open 48118 76.19 ZE 951 (Bistable): Normally Open 48119 101.45 Normally Closed 113131 101.45 Limit Value Switch (use with ZE 950): ZE 3060 24V DC 136244 279.66 230V AC 136245 303.06 Contact Protective Relay (use with ZE 950 or ZE 951): ZE 3061 24V DC 136239 332.99 230V AC 136240 259.20 Data Sensor: ZE 3000 (2 wire)* 137251 793.94 * meter size and flow rate to be advised at time of order Special Scales: Air; US GPM; HCI; Na0H; FeCI on application 26.10 469

ASV Stubbe DFM 350 meter Description: Inline variable area flowmeter Mounting: Vertical flow upwards Maximum Fluid Pressure at 20 C: 10 bar Maximum Fluid Temperature: PVCU: 60 C PA: 75 C PSU: 100 C Accuracy: ±2.5% full scale Scaling: L/hr H 2 O standard plus 0100% max flow. Special scales (on request): Air; US GPM; Na0H; FeCI Length: 350mm PVCU Inch Solvent Socket Connections Range Dia. l/h inch * 15150 1 * 30300 1 * 60600 1 * 1001000 1 1501500 1 1 /4 2502500 1 1 /4 2002000 1 1 /2 3003000 1 1 /2 4004000 2 6006000 2 100010000 2 150015000 2 1 /2 250025000 2 1 /2 1000050000 2 1 /2 PVCU Tube Polyamid Tube Polysulfone Tube 1278541 125.45 1278561 172.28 462751 125.45 475791 172.28 462761 125.45 475801 172.28 462771 125.45 475811 172.28 462791 144.91 475831 181.97 462801 144.91 475841 181.97 462841 158.95 475881 197.27 462851 158.95 475891 197.27 462891 232.69 475931 277.79 462901 232.69 475941 277.79 462911 232.69 475951 277.79 462951 437.19 475991 481.49 462961 437.19 476001 481.49 1278651 437.19 1278671 481.49 1278571 139.48 1278591 186.00 463021 139.48 476061 186.00 463031 139.48 476071 186.00 463041 139.48 476081 186.00 463061 151.86 476101 189.23 463071 151.86 476111 189.23 463111 186.00 476151 222.23 463121 186.00 476161 222.23 463161 244.76 476201 289.86 463171 244.76 476211 289.86 463181 244.76 476221 289.86 463221 466.18 476261 511.29 463231 466.18 476271 511.29 1278681 466.18 1278701 511.29 1278601 162.63 1278621 208.53 463291 162.63 476331 208.53 463301 162.63 476341 208.53 463311 162.63 476351 208.53 463331 170.69 476371 220.59 463341 170.69 476381 220.59 463381 222.23 476421 259.26 463391 222.23 476431 259.26 463431 303.56 476471 347.80 463441 303.56 476481 347.80 463451 303.56 476491 347.80 463491 562.80 476531 607.06 463501 562.80 476541 607.06 1278711 562.80 1278731 607.06 PVCU MM Solvent Socket Connections Range l/h Dia. mm * 15150 32 * 30300 32 * 60600 32 * 1001000 32 1501500 40 2502500 40 2002000 50 3003000 50 4004000 63 6006000 63 100010000 63 150015000 75 250025000 75 1000050000 75 PVCU Tube Polyamid Tube Polysulfone Tube 1278542 125.45 1278562 172.28 1278572 139.48 1278592 186.00 1278602 162.63 1278622 208.53 462752 125.45 475792 172.28 463022 139.48 476062 186.00 463292 162.63 476332 208.53 462762 125.45 475802 172.28 463032 139.48 476072 186.00 463302 162.63 476342 208.53 462772 125.45 475812 172.28 463042 139.48 476082 186.00 463312 162.63 476352 208.53 462792 144.91 475832 181.97 463062 151.86 476102 189.23 463332 170.69 476372 220.59 462802 144.91 475842 181.97 463072 151.86 476112 189.23 463342 170.69 476382 220.59 462842 158.95 475882 197.27 463112 186.00 476152 222.23 463382 222.23 476422 259.26 462852 158.95 475892 197.27 463122 186.00 476162 222.23 463392 222.23 476432 259.26 462892 232.69 475932 277.79 463162 244.76 476202 289.86 463432 303.56 476472 347.80 462902 232.69 475942 277.79 463172 244.76 476212 289.86 463442 303.56 476482 347.80 462912 232.69 475952 277.79 463182 244.76 476222 289.86 463452 303.56 476492 347.80 462952 437.19 475992 481.49 463222 466.18 476262 511.29 463492 562.80 476532 607.06 462962 437.19 476002 481.49 463232 466.18 476272 511.29 463502 562.80 476542 607.06 1278652 437.19 1278672 481.49 1278682 466.18 1278702 511.29 1278712 562.80 1278732 607.06 * Residual stocks only Please check availability Will it be in stock? Last year we shipped more than 27,500 consignments, and more than 95% were complete, first time! 470

Polypropylene Fusion Socket Connections Range l/h Dia. mm 15150 32 30300 32 60600 32 1001000 32 1501500 40 2502500 40 2002000 50 3003000 50 4004000 63 6006000 63 100010000 63 150015000 75 250025000 75 1000050000 75 PVCU Tube Polyamid Tube Polysulfone Tube 1278543 187.60 1278563 233.49 1278573 201.31 1278593 247.19 1278603 206.14 1278623 248.80 462753 187.60 475793 233.49 463023 201.31 476063 247.19 463293 206.14 476333 248.80 462763 187.60 475803 233.49 463033 201.31 476073 247.19 463303 206.14 476343 248.80 462773 210.16 475813 233.49 463043 201.31 476083 247.19 463313 206.14 476353 248.80 462793 210.16 475833 246.36 463063 217.38 476103 254.43 463333 235.91 476373 272.96 462803 210.16 475843 246.36 463073 217.38 476113 254.43 463343 235.91 476383 272.96 462843 256.05 475883 293.90 463113 282.62 476153 318.83 463383 318.83 476423 355.87 462853 256.05 475893 293.90 463123 282.62 476163 318.83 463393 318.83 476433 355.87 462893 284.22 475933 317.23 463163 293.07 476203 326.86 463433 336.56 476473 370.38 462903 284.22 475943 317.23 463173 293.07 476213 326.88 463443 336.56 476483 370.38 462913 379.23 475953 423.52 463183 390.51 476223 435.58 463453 449.27 476493 493.55 462953 506.45 475993 539.46 463223 528.17 476263 562.00 463493 600.63 476533 633.68 462963 506.45 476003 539.46 463233 528.17 476273 562.00 463503 600.63 476543 633.68 1278653 506.45 1278673 539.46 1278683 528.17 1278703 562.00 1278713 600.63 1278733 633.68 PVDF Fusion Socket Connections Range l/h Dia. mm 15150 32 30300 32 60600 32 1001000 32 1501500 40 2502500 40 2002000 50 3003000 50 4004000 63 6006000 63 100010000 63 150015000 75 250025000 75 1000050000 75 PVDF Tube Polyamid Tube Polysulfone Tube 1278574 281.01 1278594 327.71 1278604 291.46 1278624 335.74 463024 281.01 476064 327.71 463294 291.46 476334 335.74 141994 333.32 142008 370.38 463034 281.01 476074 327.71 463304 291.46 476344 335.74 141995 333.32 142009 370.38 463044 281.01 476084 327.71 463314 291.46 476354 335.74 141996 407.40 142010 443.63 463064 306.76 476104 343.80 463334 325.27 476374 362.32 141997 407.40 142011 443.63 463074 306.76 476114 343.80 463344 325.27 476384 362.32 141998 481.49 142012 517.69 463114 392.12 476154 429.15 463384 429.15 476424 466.18 141999 481.49 142013 517.69 463124 392.12 476164 429.15 463394 429.15 476434 466.18 142000 703.68 142014 747.18 463164 410.61 476204 444.43 463434 454.09 476474 487.91 142001 703.68 142015 747.18 463174 410.61 476214 444.43 463444 454.09 476484 487.91 142002 703.68 142016 747.18 463184 547.48 476224 591.80 463454 605.46 476494 650.55 142003 888.87 142017 932.33 463224 725.45 476264 759.24 463494 797.91 476534 830.89 142004 888.87 142018 932.33 463234 725.45 476274 759.24 463504 797.91 476544 830.89 142005 888.87 142019 932.33 1278684 725.45 1278704 759.24 1278714 797.91 1278734 830.89 Construction: Tube Materials: PVCU, PVDF, Polyamid (PA) or Polysulfone (PSU) End Connections: PVCU Socket or Spigot Ends Polypropylene or PVDF Sockets Float: Fully encapsulated PVDF Float Stops: PVDF ORings: EPDM (FPM option on request) Options and Spares: Limit Reed Switch: ZE 950 (Monostable): Normally Open 48118 76.19 ZE 951 (Bistable): Normally Open 48119 101.45 Normally Closed 113131 101.45 Limit Value Switch (use with ZE 950): ZE 3060 24V DC 136244 279.66 230V AC 136245 303.06 Contact Protective Relay (use with ZE 950 or ZE 951): ZE 3061 24V DC 136239 332.99 230V AC 136240 259.20 Data Sensor: ZE 3000 (2 wire)* 137251 793.94 * meter size and flow rate to be advised at time of order Special Scales: Air; US GPM; HCI; Na0H; FeCI on application 26.10 471

The BlueWhite variable area flowmeter uses a precision manufactured transparent tube with a tapered bore, into which is fitted a conical weighted float. The media (water, air, liquid or gaseous chemicals) flows vertically from the bottom to the top. As it passes through the tube, it displaces the float and raises it to a point where equilibrium is established between the lifting force of the media and the weight of the float. The top edge of the float directly indicates the flow volume on the graduated tube scale. BlueWhite manufacture a wide range of variable area flowmeters from corrosion resistant materials, including Acrylic, Polysulfone, PVCU and Glass. The range includes both inline flowmeters and panel mount flowmeters. Materials for most media: PVCU, Acrylic, Polysulfone and glass Float manufactured from PVCU, Stainless Steel Hastelloy C, PTFE, Sapphire, Carboloy or K Monel Piping connections to Plastic and Metal Pipe Systems High Level of Clarity with glasslike finish Wide Choice of optional scales BlueWhite meter Programme Overview Range InLine Panel Connection Size Model Material Liquid Air Mount Mount 1 /8 1 /4 3 /8 1 /2 3 /4 1 1 1 /2 2 F400N Acrylic 0.025 to 20 GPM 0.75 to 45 SCFM F420N Acrylic 5 to 50 GPM F430N Acrylic 4 to 100 GPM F460 Polysulfone 0.1 to 5 GPM F461 Polysulfone 1 to 20 GPM F462 Polysulfone 2 to 80 GPM F440 Polysulfone 0.025 to 10 GPM 1 to 48 SCFM F450N Polysulfone 0.1 to 10 GPM 8 to 80 SCFM F451N Polysulfone 0.5 to 40 GPM 4 to 230 SCFM F452 Polysulfone 2.0 to 175 GPM 4 to 45 SCFM F550 Acrylic 0.025 to 20 GPM 0.1 to 45 SCFM F500E Acrylic 0.2 to 72 GPM 1 to 5 SCFM F650 Glass 0.0001 to 29.72 GPM 0.7 to 59494 CC/min F670 Glass 0.5 to 5 GPM F750 PVCU 0.2 to 32 GPM 0.1 to 3 SCFM Our expert team are here to help. Call our freephone: Need advice? 0800 975 79 71 Or from outside of the UK: +44 191 521 3111 472

BlueWhite F400N Series meter Description: Inline variable area flowmeter Mounting: Vertical flow upwards Maximum Fluid Pressure at 20 C: 10 bar Maximum Fluid Temperature: 65 C Accuracy: ±5% full scale Scaling: US GPM plus L/min Body Material: Machined Acrylic End Connections: Polypropylene reinforced with aluminium stress rings Female NPT Threaded Float: PVCU, 316 St/St or Hastelloy C ORings: FPM Max Pressure Drop: 2 psi Options: High/Low level alarm Features: Back reflector for easy meter reading Standard meter PVCU Float Stainless Steel Float Hastelloy C Float Range Range Connection l/min US GPM FPT 0.11 0.0250.250 1/4" 0.11 0.0250.250 3/8" 0.44 0.11.0 3/8" 0.44 0.11.0 1/2" 1.07.5 0.22.0 3/8" 1.07.5 0.22.0 1/2" 1.511 0.33.0 3/8" 1.511 0.33.0 1/2" 2.020 0.55.0 3/8" 2.020 0.55.0 1/2" 4.038 1.010 3/4" 4.038 1.010 1" 4.064 1.017 3/4" 4.064 1.017 1" 8.080 2.020 3/4" 8.080 2.020 1" Range Range Connection l/min US GPM FPT 1.08 0.22.0 3/4 " 2.020 0.55.0 3/4 " 2.020 0.55.0 1 " 8.080 2.020 3/4 " 8.080 2.020 1 " meter for Air F40 250 LN4 147.41 F40 250 LN6 147.41 F40 375 LN6 126.07 F40 375 LN8 126.07 F40 376 LN6 126.07 F40 376 LN8 126.07 F40 377 LN6 135.90 F40 377 LN8 135.90 F40 500 LN6 126.07 F40 500 LN8 126.07 F40 750 LN12 242.84 F40 750 LN16 242.84 F41 017 LN12 242.84 F41 017 LN16 242.84 F41 000 LN12 242.84 F41 000 LN16 242.84 F40 250 LK4 318.59 F40 250 LK6 318.59 F40 375 LK6 174.78 F40 375 LK8 174.78 F40 376 LK6 174.78 F40 376 LK8 174.78 F40 377 LK6 318.59 F40 377 LK8 318.59 F40 500 LK6 318.59 F40 500 LK8 318.59 F40 750 LK12 348.19 F40 750 LK16 348.19 F41 017 LK12 348.19 F41 017 LK16 348.19 F41 000 LK12 348.19 F41 000 LK16 348.19 meter with High/Low Level Alarm PVCU Float Stainless Steel Float Hastelloy C Float Range Connection SCFM FPT 0.757.5 3/8 " 0.757.5 1/2 " 4.045 3/4 " 4.045 1 " FA41 376 LN12 518.60 FA41 500 LN12 518.60 FA41 500 LN16 518.60 FA41 000 LN12 533.07 FA41 000 LN16 553.07 Stainless Steel Float Stainless Steel Float Hastelloy C Float F40 376 GN6 124.59 F40 376 GN8 124.59 F40 750 GN12 242.84 F40 750 GN16 242.84 Options and Spares: 1 / 4" Female NPT Adaptor F4019 38.46 3 / 8" Female NPT Adaptor F4001NS 38.46 1 / 2" Female NPT Adaptor F4003NS 38.46 3 / 4" Female NPT Adaptor F4009 63.64 1" Female NPT Adaptor F4011 63.64 316 St/St Guidewire for F40250LN and F40500LN F4004 27.13 316 St/St Guidewire for F40750LN and F41017LN F4012 20.25 FPM ORing for 1 /4", 3 /8" and 1 /2" connectors 90003119 8.34 FPM ORing for 3 /4", 1" connectors F4010K 10.41 473

BlueWhite F462 Series meter Description: Inline variable area flowmeter Mounting: Vertical flow upwards Maximum Fluid Pressure at 20 C: 10 bar Maximum Fluid Temperature: 93 C Accuracy: ±2.5% full scale Scaling: US GPM plus L/min Body Material: Natural Polysulfone End Connections: Polysulfone NPT Female Threaded. PVDF or Polypropylene Inch Fusion Socket. PVDF or Polypropylene MM Fusion Socket. Float: PTFE ORings: FPM Max Pressure Drop: 2 psi Options: Can be ordered with Polycarbonate safety shield Standard meter Polysulfone Connections Polysulfone Connections Range Range Connection l/min US GPM FPT 880 220 2" 20200 550 2" 30300 880 2" F46 2200 LX32H 906.34 F46 2500 LX32H 906.34 F46 2800 LX32H 906.34 Standard meter Inch Fusion Socket Connections Polypropylene Connections Range Range Connection l/min US GPM Fusion Sock 880 220 2" 20200 550 2" 30300 880 2" Range Range Connection l/min US GPM Fusion Sock 880 220 63mm 20200 550 63mm 30300 880 63mm F46 2200 LX33G 1035.84 F46 2500 LX33G 1035.84 F46 2800 LX33G 1035.84 Standard meter MM Fusion Socket Connections Polypropylene Connections F46 2200 LX34G 1035.84 F46 2500 LX34G 1035.84 F46 2800 LX34G 1035.84 PVDF Connections F46 2200 LX33K 1683.21 F46 2500 LX33K 1683.21 F46 2800 LX33K 1683.21 PVDF Connections F46 2200 LX34K 1683.21 F46 2500 LX34K 1683.21 F46 2800 LX34K 1683.21 Options and Spares: 2" Polysulfone Female NPT Adaptor F452330N 137.82 2" Polypropylene Socket Fusion Adaptor 76001294 238.88 2" PVDF Socket Fusion Adaptor 76001295 539.95 63mm Polypropylene Socket Fusion Adaptor 76001309 238.88 63mm PVDF Socket Fusion Adaptor 76001310 568.64 FPM ORing F452043N 41.90 Union Nut F452004N 71.68 Float Stop F452002 18.06 meter with polycarbonate shield 474

BlueWhite F440N Series meter Description: Inline variable area flowmeter Mounting: Vertical flow upwards Maximum Fluid Pressure at 20 C: 10 bar Maximum Fluid Temperature: 100 C Accuracy: ±5% full scale Scaling: US GPM plus L/min or US GPH Body Material: Natural Polysulfone End Connections: Grey Polysulfone Male NPT Threaded Float: 316 St/St, Hastelloy C, PTFE or PVCU ORings: FPM Max Pressure Drop: 2 psi Options: Configurations for both InLine or Panel Mount. Optional Integral Adjustment Valve F440EA F440E Standard meter GPM and L/min Scales Range Range Connection l/min US GPM MPT 0.11 0.0250.250 3/8 " 0.11 0.0250.250 1 / 2 " 0.44 0.11.0 3/8 " 0.44 0.11.0 1 / 2 " 0.757.5 0.22.0 3/8 " 0.757.5 0.22.0 1 / 2 " 1.818 0.55.0 3/8 " 1.818 0.55.0 1 / 2 " 5.037.5 1.010.0 3/4 " LH Model LHE Model LEA Model F44 250 LH6 118.74 F44 250 LH8 118.74 F44 375 LH6 118.74 F44 375 LH8 118.74 F44 376 LH6 118.74 F44 376 LH8 118.74 F44 500 LH6 118.74 F44 500 LH8 118.74 F44 750 LH12 133.04 Range Range Connection l/min US GPM MPT 0.11 0.0250.250 3/8 " F44 250 LHK6 146.90 0.11 0.0250.250 1/2 " F44 250 LHK8 146.90 0.44 0.11.0 3/8 " F44 375 LHK6 146.90 0.44 0.11.0 1/2 " F44 375 LHK8 146.90 0.757.5 0.22.0 3/8 " F44 376 LHK6 211.38 0.757.5 0.22.0 1/2 " F44 376 LHK8 211.38 1.818 0.55.0 3/8 " F44 500 LHK6 211.38 1.818 0.55.0 1/2 " F44 500 LHK8 211.38 5.037.5 1.010.0 3/4 " F44 750 LHK12 306.94 Standard meter GPH Scale Range Connection US GPH MPT 3.030 3/8 " 3.030 1/2 " 5.060 3/8 " 5.060 1/2 " Range Connection US GPH MPT 3.030 3/8 " 3.030 1/2 " 5.060 3/8 " 5.060 1/2 " Model Variations: LH LHE LEA LHK F44 250 LHE6 142.79 F44 250 LHE8 142.79 F44 375 LHE6 142.79 F44 375 LHE8 142.79 F44 376 LHE6 142.79 F44 376 LHE8 142.79 F44 500 LHE6 142.79 F44 500 LHE8 142.79 F44 750 LHE12 166.87 F44 250 LEA6 211.95 F44 250 LEA8 211.95 F44 375 LEA6 211.95 F44 375 LEA8 211.95 F44 376 LEA6 211.95 F44 376 LEA8 211.95 F44 500 LEA6 211.95 F44 500 LEA8 211.95 F44 750 LEA12 257.05 LHK Model LKEA Model LHB Model F44 250 LKEA6 275.44 F44 250 LKEA8 275.44 F44 375 LKEA6 275.44 F44 375 LKEA8 275.44 F44 376 LKEA6 330.05 F44 376 LKEA8 330.05 F44 500 LKEA6 330.05 F44 500 LKEA8 330.05 F44 750 LKEA12 446.69 F44 250 LHB8 144.61 F44 375 LHB8 144.61 F44 376 LHB8 144.61 F44 500 LHB8 144.61 F44 750 LHB12 167.21 LH Model LHE Model LEA Model F44 330 LH6 118.74 F44 330 LH8 118.74 F44 560 LH6 118.74 F44 560 LH8 118.74 F44 330 LHE6 141.84 F44 330 LHE8 141.84 F44 560 LHE6 141.84 F44 560 LHE8 141.84 F44 330 LEA6 211.95 F44 330 LEA8 211.95 F44 560 LEA6 211.95 F44 560 LEA8 211.95 LHK Model LHE Model LHB Model F44 330 LHK6 211.95 F44 330 LHK8 211.95 F44 560 LHK6 211.95 F44 560 LHK8 211.95 Straight InLine meter 90 Elbows meter for Panel Mount Installation 90 Elbows meter with Adjustable Valve for Panel Mount Installation Straight InLine meter with Hastelloy C, PVCU or PTFE Float and Guide Rod LKEA 90 Elbows meter for Panel Mount Installation with Hastelloy C, PVCU or PTFE Float and Guide Rod LHB Straight InLine meter with Brass Adaptors F44 330 LKEA6 330.05 F44 330 LKEA8 330.05 F44 560 LKEA6 330.05 F44 560 LKEA8 330.05 Options and Spares: F44 330 LHB8 144.61 F44 560 LHB8 144.61 3 / 8" Male NPT Adaptor F4407* 19.32 3 / 8" Male NPT 90 Elbow for Panel Mount F4440K* 25.06 1 / 2" Male NPT Adaptor F4408* 19.32 1 / 2" Male NPT 90 Elbow for Panel Mount F4420P* 25.06 3 / 4" Male NPT Adaptor F4409* 24.06 3 / 4" Male NPT 90 Elbow for Panel Mount F4421K* 28.93 Half Union Connector for all F440 (except F44750) F4405P 22.95 Half Union Connector for all F44750 F4406P 26.28 Panel Mount Lock Nut for 3 /8" and 1 / 2" Adaptors F4427A 3.84 Panel Mount Lock Nut for 3 /4" Adaptors F4428A 5.16 FPM ORing for 3 /8" and 1 /2" Adaptors F4410V 5.37 FPM ORing for 3 /4" Adaptors F4411V 6.69 *Note: This part requires an ORing 475

BlueWhite F450N Series meter Description: Inline variable area flowmeter Mounting: Vertical flow upwards Maximum Fluid Pressure at 20 C: 10 bar Maximum Fluid Temperature: 100 C Accuracy: ±5% full scale Scaling: US GPM plus L/min or SCFM for Air Body Material: Natural Polysulfone End Connections: Grey Polysulfone Male NPT Threaded Float: 316 St/St, Hastelloy C or PTFE ORings: FPM Max Pressure Drop: 2 psi Options: Configurations for both InLine or Panel Mount. Optional Integral Adjustment Valve F450EA F450E Standard meter GPM and L/min Scales Range Range Connection l/min US GPM Threaded 0.44.0 0.11.0 3/8" FPT 0.44.0 0.11.0 1/2" MPT 1.07.5 0.22.0 3/8" FPT 1.07.5 0.22.0 1/2" MPT 2.020.0 0.55.0 3/8" FPT 2.020.0 0.55.0 1/2" MPT 2.020.0 0.55.0 3/4" MPT 4.040.0 1.010.0 3/4" MPT Range Range Connection l/min US GPM Threaded 0.44.0 0.11.0 3/8" FPT 0.44.0 0.11.0 1/2" MPT 1.07.5 0.22.0 3/8" FPT 1.07.5 0.22.0 1/2" MPT 2.020.0 0.55.0 3/8" FPT 2.020.0 0.55.0 1/2" MPT 2.020.0 0.55.0 3/4" MPT 4.040.0 1.010.0 3/4" MPT LHN Model LHNE Model LEA Model F45 375 LHN6 124.98 F45 375 LHN8 124.98 F45 376 LHN6 124.98 F45 376 LHN8 124.98 F45 500 LHN6 124.98 F45 500 LHN8 124.98 F45 500 LHN12 124.98 F45 750 LHN12 144.32 F45 375 LHNE6 148.86 F45 375 LHNE8 148.86 F45 376 LHNE6 148.86 F45 376 LHNE8 148.86 F45 500 LHNE6 148.86 F45 500 LHNE8 148.86 F45 500 LHNE12 148.86 F45 750 LHNE12 167.44 F45 375 LEA6 217.28 F45 375 LEA8 217.28 F45 376 LEA6 217.28 F45 376 LEA8 217.28 F45 500 LEA6 217.28 F45 500 LEA8 217.28 F45 500 LEA12 217.28 F45 750 LEA12 235.90 LHKN Model LKEA Model LHBN Model F45 375 LHKN6 211.38 F45 375 LHKN8 211.38 F45 376 LHKN6 211.38 F45 376 LHKN8 211.38 F45 500 LHKN6 211.38 F45 500 LHKN8 211.38 F45 500 LHKN12 211.38 F45 750 LHKN12 317.04 F45 375 LKEA6 341.01 F45 375 LKEA8 341.01 F45 376 LKEA6 341.01 F45 376 LKEA8 341.01 F45 500 LKEA6 341.01 F45 500 LKEA8 341.01 F45 500 LKEA12 341.01 F45 750 LKEA12 446.69 F45 375 LHBN8 168.81 F45 376 LHBN8 168.81 F45 500 LHBN8 168.81 F45 750 LHBN12 197.77 Standard meter SCFM Scale for AIR Range Connection SCFM Threaded 112 3/8" FPT 112 1/2" MPT 448 3/4" MPT GHN Model GHNE Model GEA Model F45 376 GHN6 124.98 F45 376 GHN8 124.98 F45 750 GHN12 144.32 F45 376 GHNE6 148.86 F45 376 GHNE8 148.86 F45 750 GHNE12 167.44 F45 376 GEA6 217.28 F45 376 GEA8 217.28 F45 750 GEA12 235.90 Model Variations: LH Straight InLine meter LHE 90 Elbows meter for Panel Mount Installation LEA 90 Elbows meter with Adjustable Valve for Panel Mount Installation LHKN Straight InLine meter with Hastelloy C, PVCU or PTFE Float and Guide Rod LKEA 90 Elbows meter for Panel Mount Installation with Hastelloy C, PVCU or PTFE Float and Guide Rod LHBN Straight InLine meter with Brass Adaptors GHN Straight InLine meter Calibrated for Air GHNE 90 C Elbows meter for Panel Mount Installation Calibrated for Air GEA 90 C Elbows meter with Adjustable Valve for Panel Mount Installation Calibrated for Air Options and Spares: 3 / 8" Male NPT Adaptor F45011N* 19.32 3 / 8" Male NPT 90 Elbow for Panel Mount F4441K* 28.93 1 / 2" Male NPT Adaptor F45013N* 19.32 1 / 2" Male NPT 90 Elbow for Panel Mount F4442K* 28.93 3 / 4" Male NPT Adaptor F4409* 24.06 3 / 4" Male NPT 90 Elbow for Panel Mount F4421K* 28.93 Half Union Connector for all F450 F4406P 26.28 Lock Nut for 1 /2" and 3 /8" adaptors F4427A 3.84 Lock Nut for 3 /4" adaptors F4428A 5.16 FPM ORing for all F450 F4411V 6.69 Wireholder for F450N except F45750N F45007 7.77 Wireholder for F45750N F45019 9.66 *Note: This part requires an ORing 476

BlueWhite F451N Series High Volume meter Description: Inline variable area flowmeter Mounting: Vertical flow upwards Maximum Fluid Pressure at 20 C: 10 bar Maximum Fluid Temperature: 100 C Accuracy: ±3% full scale Scaling: US GPM plus L/min or SCFM for Air Body Material: Natural Polysulfone End Connections: Grey Polysulfone Female NPT Threaded Float: 316 St/St, Hastelloy C or PTFE ORings: FPM Max Pressure Drop: 1 psi Options: Configurations for both InLine or Panel Mount. Can be ordered with Polycarbonate safety shield. Standard meter GPM and L/min Scales Range Range Connection l/min US GPM FPT 220 0.56.0 1" 220 0.56.0 1 1 /2" 440 1.010.0 1" 440 1.010.0 1 1 /2" 7.575 2.020.0 1" 7.575 2.020.0 1 1 /2" 12115 3.030.0 1" 12115 3.030.0 1 1 /2" 15155 4.040.0 1" 15155 4.040.0 1 1 /2" LHN Model F45 1006 LHN 384.77 F45 1006 LHN24 430.77 F45 1001 LHN 409.54 F45 1001 LHN24 430.77 F45 1002 LHN 429.84 F45 1002 LHN24 451.04 F45 1003 LHN 470.98 F45 1003 LHN24 492.17 F45 1004 LHN 494.39 F45 1004 LHN24 515.59 LHNE Model F45 1006 LHNE 474.13 F45 1001 LHNE 474.13 F45 1002 LHNE 492.25 F45 1003 LHNE 529.95 F45 1004 LHNE 551.15 Elbow version with polycarbonate shield Range Range Connection l/min US GPM FPT 220 0.56.0 1" 220 0.56.0 1 1 /2" 440 1.010.0 1" 440 1.010.0 1 1 /2" 7.575 2.020.0 1" 7.575 2.020.0 1 1 /2" 12115 3.030.0 1" 12115 3.030.0 1 1 /2" 15155 4.040.0 1" 15155 4.040.0 1 1 /2" LHNC Model LHKN Model LHBPN Model F45 1006 LHNC 541.42 F45 1006 LHNC24 584.45 F45 1001 LHNC 562.20 F45 1001 LHNC24 562.20 F45 1002 LHNC 582.49 F45 1002 LHNC24 603.71 F45 1003 LHNC 623.65 F45 1003 LHNC24 644.86 F45 1004 LHNC 647.03 F45 1004 LHNC24 668.25 F45 1006 LHKN 701.60 F45 1006 LHKN24 722.80 F45 1001 LHKN 701.60 F45 1001 LHKN24 722.80 F45 1002 LHKN 754.51 F45 1002 LHKN24 775.74 F45 1003 LHKN 808.66 F45 1003 LHKN24 829.90 F45 1004 LHKN 889.27 F45 1004 LHKN24 910.49 F45 1006 LHBPN 555.84 F45 1001 LHBPN 576.39 F45 1002 LHBPN 623.27 F45 1003 LHBPN 620.14 F45 1004 LHBPN 650.95 Standard meter SCFM Scale for AIR Range Connection SCFM FPT 880 1" 880 1 1 /2" GHN Model F45 1002 GHN 429.84 F45 1002 GHN24 451.04 Model Variations: LHN LHNE HNC LHKN Straight InLine meter 90 Elbows meter for Panel Mount Installation (MPT except for F451006 which is FPT) Straight InLine meter with Polycarbonate Shield Straight InLine meter with Hastelloy C or PTFE Float and Guide Rod LHBPN Straight InLine meter with Brass Adaptors GHN Straight InLine meter Calibrated for Air Options and Spares: Union Nut F45038N 45.49 1" Polysulfone Female NPT Adaptor F45030N 64.00 1" Brass Female NPT Adaptor F45047N 141.78 1 1 /2" Polysulfone Female NPT Adaptor 76000967 64.00 1" Male NPT 90 Elbow for Panel Mount F45031 46.04 FPM ORing 2136V 14.82 Wireholder for 0.56, 110, 220 GPM; 880 SCFM F45025 9.56 Wireholder for 330, 440 GPM F450252 9.56 477

BlueWhite F452 Series meter Description: Inline variable area flowmeter Mounting: Vertical flow upwards Maximum Fluid Pressure at 20 C: 9 bar Maximum Fluid Temperature: 65 C Accuracy: ±2% full scale Scaling: US GPM plus L/min or SCFM for Air Body Material: Natural Polysulfone End Connections: Grey Polysulfone Female NPT Threaded reinforced with aluminium stress rings Float: 316 St/St, Hastelloy C or PTFE ORings: FPM Max Pressure Drop: 2 psi Standard meter GPM and L/min Scales Range Range Connection Stainless Steel Float l/min US GPM FPT 878 220 2" F45 2020 LH 832.25 30230 660 2" F45 2060 LH 832.25 40300 1080 2" F45 2080 LH 832.25 20380 5100 2" F45 2100 LH 832.25 60500 15130 2" F45 2130 LH 882.92 75675 20175 2" F45 2175 LH 882.92 Hastelloy C or PTFE Float F45 2020 LHK 1212.90 F45 2060 LHK 1261.19 F45 2080 LHK 1261.19 F45 2100 LHK 1261.19 F45 2130 LHK 1300.37 F45 2175 LHK 1300.37 Range Range Connection l/min US GPM FPT 878 220 2" 30230 660 2" 40300 1080 2" 20380 5100 2" 60500 15130 2" 75675 20175 2" Model Variations: LH LHK LHC LHKC GH GHC Stainless Steel Float Hastelloy C or PTFE Float F45 2020 LHC 1041.18 F45 2020 LHKC 1424.25 F45 2060 LHC 1041.18 F45 2060 LHKC 1472.54 F45 2080 LHC 1041.18 F45 2080 LHKC 1472.54 F45 2100 LHC 1041.18 F45 2100 LHKC 1472.54 F45 2130 LHC 1094.28 F45 2130 LHKC 1511.74 F45 2175 LHC 1094.28 F45 2175 LHKC 1511.74 Straight InLine meter with 316 St/St Float 90 Elbows meter for Panel Mount Installation (MPT except for F451006 which is FPT) Straight InLine meter with Polycarbonate Shield Straight InLine meter with Hastelloy C or PTFE Float and Guide Rod Straight InLine meter with Brass Adaptors Straight InLine meter Calibrated for Air Standard meter SCFM Scale for AIR Range Connection Stainless Steel Float SCFM FPT 440 2" F45 2040 GH 829.80 30230 2" F45 2250 GH 829.80 Hastelloy C or PTFE Float F45 2040 GHC 1041.18 F45 2250 GHC 1041.18 Options and Spares: Union Nut F452004 72.37 2" Polysulfone Female NPT Adaptor F452330 139.14 FPM ORing F452043 30.77 Wireholder F452002 18.06 St/St Guide Wire F452287 124.97 Float Stop F452332 1.24 478

BlueWhite F550 Panel Mount meter Description: Inline variable area flowmeter for panel mounting Mounting: Vertical flow upwards Maximum Fluid Pressure at 20 C: 17 bar Maximum Fluid Temperature: 93 C Accuracy: ±5% full scale Scaling: US GPM plus L/min Body Material: Machined Acrylic End Connections: Male NPT Threaded Float: 316 Stainless Steel (PTFE on F55005L) ORings: FPM Max Pressure Drop: 2 psi Features: Bulkhead nuts attach directly to inside panel mounting screws not required Options: Optional Adjustment Valve Standard meter GPM and L/min Scales Range Range Connection Standard Model l/min US GPM MPT 0.11 0.0250.250 1/4" F55 250 L 169.07 0.44 0.11.0 3/8" F55 375 L 164.13 0.757.5 0.22.0 3/8" F55 376 L 164.13 220 0.55.0 1/2" F55 500 L 164.13 440 110 3/4" F55 750 L 194.65 318 15 1" F55 005 L 231.80 440 110 1" F55 010 L 231.80 560 115 1" F55 015 L 231.80 7.575 220 1" F55 200 L 231.80 Standard meter SCFM Scale for Air Range Connection SCFM MPT 0.11.2 1/4" 0.54.5 3/8" 17 3/8" 220 1/2" 445 3/4" Standard Model F55 250 G 169.07 F55 375 G 164.13 F55 376 G 164.13 F55 500 G 164.13 F55 750 G 194.65 Model with Valve F55 250 LA 249.99 F55 375 LA 229.85 F55 376 LA 229.85 F55 500 LA 229.85 F55 750 LA 320.38 F55 010 LA 339.16 F55 015 LA 339.16 F55 200 LA 339.16 Model with Valve F55 250 GA 249.99 F55 375 GA 229.85 F55 376 GA 229.85 F55 500 GA 229.85 F55 750 GA 320.38 Options and Spares: Adaptor for F55250 76001079* 30.72 Adaptor for F55375, F55376 91001141* 18.21 Adaptor for F55500 91001142* 18.21 Adaptor for F55750 91001143* 24.99 Adaptor for F55200, F55005, F55010, F55015 91001144* 35.30 Adaptor Adjustable Valve 1 /4" MPT 76001153* 3.43 Adaptor Adjustable Valve 3 /8" MPT 91001173* 19.74 Adaptor Adjustable Valve 1 /2" MPT 91001174* 19.74 Adaptor Adjustable Valve 3 /4" MPT 91001175* 26.84 Adaptor Adjustable Valve 1" MPT 91001176* 38.28 ORing for Adaptor 1 /4" (Adj. Model) 90003034 3.77 ORing for Adaptor 3 /8" and 1 /2" (Adj. Model) 90003081 5.96 ORing for Adaptor 3 /4" (Adj. Model) 90003110 10.40 ORing for Adaptor 1" (Adj. Model) 90003082 6.41 Cap for F55250 76001080 14.64 Cap for F55375, F55376, F55500 91001032 16.70 Cap for F55750 91001033 19.46 Cap for F55200, F55005, F55010, F55015 91001160 45.35 Panel Lock Nut 3 /4" MPT 91001171 5.21 Panel Lock Nut 1" MPT 91001172 6.07 Panel Lock Nut 1 /4" and 3 /8" MPT 91001153 3.43 Panel Lock Nut 1 /2" MPT 91001154 3.84 ORing for Adaptor 1 /4" (Std. Model) 90003072 5.55 ORing for Adaptor 3 /8" and 1 /2" (Std. Model) 90003034 3.77 ORing for Adaptor 3 /4" (Std. Model) 90003081 5.86 ORing for Adaptor 1" (Std. Model) 90003110 10.40 *Note: This part requires an ORing 479

digital flow meters BW DigiMeter F1000 F1000 Series paddle wheel flow meters provide the performance and features of electronic meters, without the need for an external electricity supply. A large range of installation tees and saddles enables the meter to be fitted on pipe sizes up to 12"/315mm. Ideal for use with water and mildly corrosive liquids. Main Features Factory calibrated 6 digit LCD, up to 4 decimal places. Display & update time: every 2 seconds Battery operated (2 batteries alkaline AAA) Suitable for outdoor installations Total reset function can be disabled Tamper proof Installs quickly on existing pipe Available sizes 1 1 /2" 12" / 20mm 315mm Can be mounted horizontally or vertically Minimal maintenance required Custom calibration available Three versions of this digital flowmeter are available: F1000RB Rate of flow display Specifications Accuracy: +/ 2% full scale Repeatability: +/ 1% full scale Display: 6digit LCD, rate and total Max pressure: (20bar) @ 20ºC Max fluid temp @ 0 psi: 60ºC Max ambient temperature: 10º to +43ºC Minimal pressure drop Calibration units: LPM, m3/min, LPH Materials: Sensor body/paddle/axle: PVDF Mounting tee: Polypropylene, PVCu Mounting saddle: 1 1 /2" to 3": PVDF, 6" to 10": PVC Sensor ORings: Viton Power: Two AAA bateries (included) Battery life: 1 year minimum Enclosure: NEMA 4X, (IP56), ABS F1000TB Total flow display F1000RT Rate & total display 480

digital flow meters BW DigiMeter F1000 Polypropylene Body Male BSP Pipe Size LPM Rate Only Total Only Rate & Total M/BSP Range Model Number Model Number Model Number 3 / 8" 3 to 30 RB375MB1LPM1 TB375MB1LPM1 RT375MB1LPM1 3 / 8" 1 to 10 RB375MB1LPM2 TB375MB1LPM2 RT375MB1LPM2 1 / 2" 7 to 70 RB500MB1LPM1 TB500MB1LPM1 RT500MB1LPM1 1 / 2" 2 to 20 RB500MB1LPM2 TB500MB1LPM2 RT500MB1LPM2 3 / 4" 11 to 110 RB750MB1LPM1 TB750MB1LPM1 RT750MB1LPM1 3 / 4" 3 to 30 RB750MB1LPM2 TB750MB1LPM2 RT750MB1LPM2 1" 20 to 200 RB100MB1LPM1 TB100MB1LPM1 RT100MB1LPM1 1" 7 to 70 RB100MB1LPM2 TB100MB1LPM2 RT100MB1LPM2 1 1 /2" 15 to 150 RB150MB1LPM1 TB150MB1LPM1 RT150MB1LPM1 1 1 /2" 25 to 250 RB150MB1LPM2 TB150MB1LPM2 RT150MB1LPM2 1 1 /2" 40 to 400 RB150MB1LPM3 TB150MB1LPM3 RT150MB1LPM3 2" 15 to 150 RB200MB1LPM1 TB200MB1LPM1 RT200MB1LPM1 2" 25 to 250 RB200MB1LPM2 TB200MB1LPM2 RT200MB1LPM2 2" 40 to 400 RB200MB1LPM3 TB200MB1LPM3 RT200MB1LPM3 2" 70 to 700 RB200MB1LPM4 TB200MB1LPM4 RT200MB1LPM4 Installation Requirements: Minimum Straight Pipe Length Requirements The meter s accuracy is affected by disturbances such as pumps, elbows, tees, valves etc., in the flow stream. Install the meter in a straight run of pipe as far as possible from any disturbances. The distance required for accuracy will depend on the type of disturbance. Minimum Inlet Minimum Outlet Type of Disturbance Pipe Length Pipe Length Flange 10 x Pipe I.D. 5 x Pipe I.D. Reducer 15 x Pipe I.D. 5 x Pipe I.D. 90º Elbow 20 x Pipe I.D. 5 x Pipe I.D. Two Elbows 1 Direction 25 x Pipe I.D. 5 x Pipe I.D. Two Elbows 2 Directions 40 x Pipe I.D. 5 x Pipe I.D. Pump or Gate Valves 50 x Pipe I.D. 5 x Pipe I.D. Mounting Location The meter is designed to withstand outdoor conditions. A cool, dry location, where the unit can be easilt serviced is recommended. The meter can be mounted on horizontal or vertical runs of pipe. Mounting at the vertical (twelve o clock) position on horizontal pipe is recommended. Mounting anywhere around the diameter of vertical pipe is acceptable, however, the pipe must be completely full of water at all times. Back pressure is essential on downward flows. See the minimum straight length of pipe requirement chart above. The meter can accurately measure flow from either direction. Stream Requirements: Measuring accuracy requires a fully developed turbulent flow profile. Pulsating, swirling and other disruptions in the flow stream will effect accuracy. conditions with a Reynolds Number greater than 4000 will result in a fully developed turbulent flow. A Reynolds Number less than 2000 is laminar flow and may result in inaccurate readings. REYNOLDS NUMBER EQUATION: REYNOLDS NUMBER = 3160 x Q x G D x V Where: rate of the fluid in GPM = Q Specific gravity of the fluid = G Pipe inside diameter in inches = D Fluid viscocity in centepoise = V 481

digital flow meters BW DigiMeter F1000 PVCu Tee Solvent Socket LPM Rate Only Total Only Rate & Total Pipe Size Range Model Number Model Number Model Number 1" 25 to 250 RB100ATLPM1 TB100ATLPM1 RT100ATLPM1 1 1 /2" 60 to 600 RB150ATLPM1 TB150ATLPM1 RT150ATLPM1 2" 100 to 1000 RB200ATLPM1 TB200ATLPM1 RT200ATLPM1 LPM Models BW DigiMeter F1000 PVDF & PVCu Saddle LPM Rate Only Total Only Rate & Total Pipe Size Range Model Number Model Number Model Number 50mm 70 to 700 RB050P0LPM1 TB050P0LPM1 RT050P0LPM1 63mm 110 to 1100 RB063P0LPM1 TB063P0LPM1 RT063P0LPM1 75mm 150 to 1500 RB075P0LPM1 TB075P0LPM1 RT075P0LPM1 90mm 230 to 2300 RB090P0LPM1 TB090P0LPM1 RT090P0LPM1 110mm 350 to 3500 RB110P0LPM1 TB110P0LPM1 RT110P0LPM1 160mm 720 to 7200 RB160P0LPM1 TB160P0LPM1 RT160P0LPM1 200mm 1150 to 11500 RB200P0LPM1 TB200P0LPM1 RT200P0LPM1 250mm 1700 to 17000 RB250P0LPM1 TB250P0LPM1 RT250P0LPM1 315mm 2700 to 27000 RB315P0LPM1 TB315P0LPM1 RT315P0LPM1 Models for METRIC PN10 Pipe (DIN 8062) display in litres per minute Model Number Matrix: 482

digital flow meters BW DigiMeter F2000 F2000 Series electronic insertion style flowmeters, are well suited for monitoring flow in municipal water and wastewater applications. The clamp on saddle fitting and insertion sensor is quickly installed on imperial pipe sizes from 1 1 /2" through 12" and metric pipe sizes from 50 mm through 315 mm. The electronic display and communication enclosure can be mounted directly to the sensor, or remotely mounted to a pipe or panel. Standard models display flow rate and accumulated total flow, and include an NPN open collector output for communication with dataloggers, SCADA systems, and other external devices. Main Features 8 digit LCD, up to 4 decimal places. Display & update time: every 2 seconds. AC/DC Transformer or battery operated (RT models only) Factory programmed with calibration certificate Field programmable via front panel touch pad. Front panel security lockout. Total reset function can be disabled. Tamper proof. Suitable for outdoor installations. Installs quickly on existing pipe. Available pipe sizes 1 1 /2" 12"/20mm 315mm Can be mounted horizontally or vertically Minimal Maintenance Required Four versions of this digital flowmeter are available: RT Rate & Totalizer. Transformer or battery operated AQ 420mA, 010 VDC analogue output, Rate & Totalizer. Transformer operated Specifications Accuracy: +/1% full scale Repeatability: +/ 1% full scale Display: 8digit LCD, rate and total Signal Distance: AC sine wave sensor = 60m (200ft) Optional Hall effect sensor = 1.6km (1 mile) Max pressure: (20bar) @ 20ºC Max fluid temp @ 0 psi : 60ºC Max Ambient temperature: 10º to + 43ºC Minimal pressure drop Calibration Units: LPM, m3/min, LPH Materials: Sensor body/paddle/axle: PVDF Mounting Tee: Polypropylene, PVCu Mounting saddle: 1 1 /2" to 3": PVDF, 6" to 10": PVC Sensor ORings: Viton Power: AC/DC Transformer or battery operated (RT models only) Two AAA batteries (included) Battery life: 1year minimum Enclosure: NEMA 4X, (IP56), ABS PC Batch Processing, flow rate alarm, proportional chemical metering, flow rate & totalizer. Transformer operated. AP Anaologue output Batch Processing, flow rate alarm, proportional chemical metering, flow rate & totalizer. Transformer operated. 483

digital flow meters BW DigiMeter F2000 Tee Fitting, remote mount display Rate & Total Analog Process Pipe Size LPM Display Output Control M/BSP Range Model Number Model Number Model Number 3 / 8" 3 to 30 RTP238MB1LM1 AOP238MB1LM1 PCP238MB1LM1 3 / 8" 1 to 10 RTP238MB2LM2 AOP238MB2LM2 PCP238MB2LM2 1 / 2" 7 to 70 RTP250MB1LM1 AOP250MB1LM1 PCP250MB1LM1 1 / 2" 2 to 20 RTP250MB2LM2 AOP250MB2LM2 PCP250MB2LM2 3 / 4" 11 to 110 RTP275MB1LM1 AOP275MB1LM1 PCP275MB1LM1 3 / 4" 3 to 30 RTP275MB2LM2 AOP275MB2LM2 PCP275MB2LM2 1" 20 to 200 RTP210MB1LM1 AOP210MB1LM1 PCP210MB1LM1 1" 7 to 70 RTP210MB2LM2 AOP210MB2LM2 PCP210MB2LM2 1 1 /2" 15 to 150 RTP215MB1LM1 AOP215MB1LM1 PCP215MB1LM1 1 1 /2" 25 to 250 RTP215MB2LM2 AOP215MB2LM2 PCP215MB2LM2 1 1 /2" 40 to 400 RTP215MB3LM3 AOP215MB3LM3 PCP215MB3LM3 2" 15 to 150 RTP220MB1LM1 AOP220MB1LM1 PCP220MB1LM1 2" 25 to 250 RTP220MB2LM2 AOP220MB2LM2 PCP220MB2LM2 2" 40 to 400 RTP220MB3LM3 AOP220MB3LM3 PCP220MB3LM3 2" 70 to 700 RTP220MB4LM4 AOP220MB4LM4 PCP220MB4LM4 Display in litres per minute Rate & Total Analog Process Pipe Size IGM Display Output Control M/BSP Range Model Number Model Number Model Number 3 / 8" 0.8 to 8 RTP238MB1IM1 AOP238MB1IM1 PCP238MB1IM1 3 / 8" 0.4 to 4 RTP238MB2IM2 AOP238MB2IM2 PCP238MB2IM2 1 / 2" 2 to 20 RTP250MB1IM1 AOP250MB1IM1 PCP250MB1IM1 1 / 2" 0.5 to 5 RTP250MB2IM2 AOP250MB2IM2 PCP250MB2IM2 3 / 4" 3 to 30 RTP275MB1IM1 AOP275MB1IM1 PCP275MB1IM1 3 / 4" 0.8 to 8 RTP275MB2IM2 AOP275MB2IM2 PCP275MB2IM2 1" 5 to 50 RTP210MB1IM1 AOP210MB1IM1 PCP210MB1IM1 1" 2 to 20 RTP210MB2IM2 AOP210MB2IM2 PCP210MB2IM2 1 1 /2" 4 to 40 RTP215MB1IM1 AOP215MB1IM1 PCP215MB1IM1 1 1 /2" 6 to 60 RTP215MB2IM2 AOP215MB2IM2 PCP215MB2IM2 1 1 /2" 10 to 100 RTP215MB3IM3 AOP215MB3IM3 PCP215MB3IM3 2" 4 to 40 RTP220MB1IM1 AOP220MB1IM1 PCP220MB1IM1 2" 6 to 60 RTP220MB2IM2 AOP220MB2IM2 PCP220MB2IM2 2" 10 to 100 RTP220MB3IM3 AOP220MB3IM3 PCP220MB3IM3 2" 20 to 200 RTP220MB4IM4 AOP220MB4IM4 PCP220MB4IM4 Display in imperial gallons per minute Model Number Matrix: 484

digital flow meters BW DigiMeter F2000 Saddle Fitting, remote mount display LPM Rate & Total Analog Output Process Control Pipe Size Range Model Number Model Number Model Number 50mm 70 to 700 RTP105K0LM1 AOP105K0LM1 PCP105K0LM1 63mm 110 to 1100 RTP106K0LM1 AOP106K0LM1 PCP106K0LM1 75mm 150 to 1500 RTP108A0LM1 AOP108A0LM1 PCP108A0LM1 90mm 230 to 2300 RTP109K0LM1 AOP109K0LM1 PCP109K0LM1 110mm 350 to 3500 RTP111A0LM1 AOP111A0LM1 PCP111A0LM1 160mm 720 to 7200 RTP116A0LM1 AOP116A0LM1 PCP116A0LM1 200mm 1150 to 11500 RTP120A0LM1 AOP120A0LM1 PCP120A0LM1 250mm 1700 to 17000 RTP125A0LM1 AOP125A0LM1 PCP125A0LM1 315mm 2700 to 27000 RTP131A0LM1 AOP131A0LM1 PCP131A0LM1 Models for METRIC PN10 pipe (DIN 8062) GPM Rate & Total Analog Output Process Control Pipe Size Range Model Number Model Number Model Number 1 1 /2" 15 to 150 RTP115K4GM1 AOP115K4GM1 PCP115K4GM1 2" 30 to 300 RTP120K4GM1 AOP120K4GM1 PCP120K4GM1 2 1 /2" 40 to 400 RTP125A4GM1 AOP125A4GM1 PCP125A4GM1 3" 60 to 600 RTP130K4GM1 AOP130K4GM1 PCP130K4GM1 4" 100 to 1000 RTP140A4GM1 AOP140A4GM1 PCP140A4GM1 6" 250 to 2500 RTP160A4GM1 AOP160A4GM1 PCP160A4GM1 8" 400 to 4000 RTP180A4GM1 AOP180A4GM1 PCP180A4GM1 10" 600 to 6000 RTP1100A4GM1 AOP1100A4GM1 PCP1100A4GM1 12" 800 to 8000 RTP1120A4GM1 AOP1120A4GM1 PCP1120A4GM1 Models for U.S. IPS sch40 pipe (ASTM 1785) Stream Requirements: Measuring accuracy requires a fully developed turbulent flow profile. Pulsating, swirling and other disruptions in the flow stream will effect accuracy. conditions with a Reynolds Number greater than 4000 will result in a fully developed turbulent flow. A Reynolds Number less than 2000 is laminar flow and may result in inaccurate readings. REYNOLDS NUMBER = 3160 x Q x G D x V Where: rate of the fluid in GPM = Q Specific gravity of the fluid = G Pipe inside diameter in inches = D Fluid viscocity in centepoise = V Installation Requirements: Minimum Straight Pipe Length Requirements The meter s accuracy is affected by disturbances such as pumps, elbows, tees, etc., in the flow stream. Install the meter in a straight run of pipe as far as possible from any disturbances. The distance required for accuracy will depend on the type of disturbance. Minimum Inlet Minimum Outlet Type of Disturbance Pipe Length Pipe Length Flange 10 x Pipe I.D. 5 x Pipe I.D. Reducer 15 x Pipe I.D. 5 x Pipe I.D. 90º Elbow 20 x Pipe I.D. 5 x Pipe I.D. Two Elbows 1 Direction 25 x Pipe I.D. 5 x Pipe I.D. Two Elbows 2 Directions 40 x Pipe I.D. 5 x Pipe I.D. Pump or Gate Valves 50 x Pipe I.D. 5 x Pipe I.D. Mounting Location The meter is designed to withstand outdoor conditions. A cool, dry location, where the unit can be easilt serviced is recommended. The meter can be mounted on horizontal or vertical runs of pipe. Mounting at the vertical (twelve o clock) position on horizontal pipe is recommended. Mounting anywhere around the diameter of vertical pipe is acceptable, however, the pipe must be completely full of water at all times. Back pressure is essential on downward flows. See the minimum straight length of pipe requirement chart above. The meter can accurately measure flow from either direction. 485

flow x3 flow monitoring The X3 System includes a complete range of paddle wheel flow sensors, instruments and sensor installation fittings. Also included are insertion type electromagnetic flow transmitters. X3 products provide high quality and stateoftheart technology. All products are manufactured under ISO 9001:2000 and conform to the highest CE standrds. High Accuracy ± 0.75% of full scale with standard K factor ± 1% of reading value with field calibration Excellent Low Measurement Accurately measures flow velocities down to 0.15m/s (0.5ft./sec.) Instruments New design More Outputs X3 instruments are supplied standard with a large offering of control outputs, including 4 to 20mA, open collector (pulse) and relay outputs. All have 3 line LCD displays and LED status indication for the control outputs. Modular Design 1/4 DIN Size Only with X3 can the same instrument be mounted in 3 different ways: directly to the flow sensor, or remotely in a panel or wall mounted. Large Velocity Range The frequency output is linearly proportional to flow rate from 0.15 to 8 m/s (0.5 to 25 ft./sec.). Approximately 45 Hz/m/s. Easily Installed into all types and sizes of piping Sensor installation fittings are available in a large selection of types, materials and pipe sizes up to 24 /630mm. Direct Mount Panel Mount Wall Mount Sensors Designed for Corrosive and Dirty Services X3 paddle wheel flow meters are of corrosion resistant solid plastic construction. They are recommended for services with up to 10% solids*. Bearings and sensor body near the rotor are designed to be selfcleaning and small magnets in the rotor blade lessen the chance of fouling due to accumulation of magnetic particules in the process. Low Cost Blind Transmitters Available Blind Transmitters are available with module directly mounted to the flow sensor. These are less expensive than the standard direct mount instrument/sensor packages. Submersible Sensors Available NEMA 6, 6P (IP68) models are available for outdoor or submersible installations. *Particle size not exceeding 0.5mm cross section or length 486

flow x3 flow monitoring Designed for Heavy Duty Industrial Applications Instruments have a NEMA 4, 4X monolithic clear polycarbonate enclosure in 1/4 DIN size, epoxy encapsulated electronics and a 5 button silicone rubber keypad. Easy Setup Setting up the instrument is easy using the keypad and selfexplanatory menus. Plugin terminals make instrument connection and removal easy. Auto calibration provides automatic calculation of K factors. Removable Cover 3 line LCD Display two 12digit Alphanumeric lines both Rate and Total appear together one Output Status Icon line 5 Button Silicone Rubber Keypad 1/4 DIN size Monolithic Enclosure Status Displays, up to 3 LEDs Long Service Life X3 have a ceramic rotor shaft and bearings. On aggressive chemicals and services containing grit, X3 sensors have outlasted other types with metal shafts and no bearings. Ceramic Shaft & Bearings High chemical resistance Long Life 20 years/m/s Self cleaning design Sensor Body Available in CPVC, PVDF, 316L Stainless Steel or Brass 2 sensor lengths for 1/2" to 24" pipes Integrated Solid State Electronics Encapsulated in epoxy for corrosion resistance 5 Blade ECTFE (Halar ) Rotor Open channel design avoids cavitation Five small magnets within rotor blades produce five pulses per revolution 487

type F3.00 and F3.01 flow sensors The Type F3.00/F3.01 Paddle Wheel Sensors are designed for use with solidfree liquids. A square wave output signal is generated with frequency proportional to rate of rotor rotation and flow velocity. This pulse output is normally fed to a X3 flow monitor/transmitter, blind transmitter, batch controller or adjustable flow switch. For simple flow indication the output can be fed directly to a computer. Two types of sensors are available, Hall Effect which requires a 5 to 24 VDC power supply and Coil Effect which operates with less power, 3 to 5 VDC. Coil is required with the battery powered flow monitor. Hall Effect signals may be transmitted up to 300m without the need for conditioning whereas Coil Effect signals may be transmitted up to 16m without conditioning. Main Features CPVC, PVDF, Stainless Steel or Brass sensor body Easy insertion system Different versions for remote and compact installations Measurement range over 50:1 High chemical resistance Battery powered version 420 ma output MIN alarm relay output Applications Water treatment and regeneration Industrial wastewater treatment and recovery Textile finishing Water distribution Processing and manufacturing industry Filtration systems Chemical production Liquid delivery systems Cooling water monitoring Heat Exchangers Swimming pools Pump protection Engineering Data The flow sensor is available with Hall effect transducer (standard) and Coil effect transducer (battery operated) The Hall sensor operates with a power supply from 5 to 24 VDC @ <30 ma The Coil sensor operates with a power supply from 3 to 5 VDC @ <10 µa The standard output is a square wave with a frequency of 45 Hz per m/s (13.7 Hz per ft/s) nominal The output signal is provided directly via electric cable or via a cable plug according to DIN 43650B/ISO 6952. Supplied cable is standard 8m (26.4 ft) long, with a maximum length of 300 m (990 ft) for Hall sensor and 16 m (52.8 ft) for Coil sensor In the versions with 420 ma or MIN alarm output, an additional IP65 housing is plugged onto the sensor. Output signals are available on a terminal strip inside via a PG11 cable gland. The sensor F3.30 with 420 ma output and the sensor F3.15 with MIN alarm output require a power supply from 12 to 24 VDC. The nominal measuring range is from 0.15 to 8 m/s (0.5 to 25 ft/s). 488

type F9.00, F9.01 and F9.02 flow monitors/transmitters Type F9.00, F9.01 and F9.02 Monitors/Transmitters are designed to process the pulse signals from all X3 Hall Effect flow sensors. The instruments supply voltage to the flow sensor. All units are supplied standard with a large offering of control outputs, including 4 to 20mA, open collector (pulse) and relay outputs. All have 3 line LCD displays and LED status indication for the control outputs. Modular design allows the same instrument to be mounted in three different ways: directly to the flow sensor or remotely either panel or wall mount. Self explaining calibration menus allow a customized set up of all measuring parameters and the state of the art electronic design ensures longterm reliable and stable signals. Main Features Permanent and resettable totalizer Adjustable outputs Relay and Open Collector options Installation flexibility 3 line alphanumeric LCD IP65 monolithic packaging 5 button keypad Output simulation for system testing One packaging for compact/pipe, panel or wall installation Self explaining calibration menus Autocalibration Engineering Data The flow transmitter is designed with only one packaging for compact/pipe, panel or wall installation The flow transmitter has 1 /4 DIN panel mount standard dimensions: 96 x 96 mm (3.8 x 3.8 inch) The instrument meets IP65 standards The instrument provides flow rate indication and dual totalization with fully scaleable engineering units The flow transmitter is equipped with a 3 line LCD: 2 x 12 alphanumeric lines and 1 icon line The flow transmitter is equipped with a silicone rubber 5 button keypad The flow transmitter is compatible with all FLS X3 Hall Effect Sensor The instrument provides autocalibration and simulation options Applications Displays control and measuring Water treatment and regeneration Industrial wastewater treatment and recovery Water distribution Leak detection Processing and manufacturing industry Textile finishing Finishing systems Chemical Industry Liquid delivery systems Auxiliary plants Swimming pools and spas Rate Resettable Total NonResettable Total 5 digits 6 digits 10 digits Our expert team are here to help. Call our freephone: Need advice? 0800 975 79 71 Or from outside of the UK: +44 191 521 3111 489

instrument mounting kits Compact Mounting : F9.KC1 Contains plastic adaptor with gasket, compact cap, locking ring and 4 fixing screws Panel Mounting : F9.KP1 Contains mounting bracket with gasket Wall Mounting : F9.KW1 Contains plastic adaptor with gasket and fixing screws 490

installation fittings Tee Fittings For connection to PVCU, PVCC, PP and PVDF. Available in sizes up to 50mm/1 1 /2" Clamp Saddle Fittings Suitable for use with both metric and inch size pipe from 63mm/2" 315mm/12" Metal StrapOn Saddles Primarily for use with metal pipes, but can be used with thermoplastic pipe also. Available in sizes from 90mm/3" 450mm/18" Wafer Fittings For mounting between flanges in pipe of all materials. Sizes from 250mm/10" 315mm/12" Stainless Steel Tee Fittings For connection to stainless steel piping only. In sizes 3 / 4 ", 1" & 1 1 / 4 " 491