Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Similar documents
Operation. D1VW Solenoid Operated Plug-In Conduit Box Style

Directional Control Valves. Application. Features. Operation. D3W Solenoid Operated Conduit Cavity Style. D3W Solenoid Operated Hirschmann (DIN) Style

Operation. D1VW Solenoid Operated Plug-In Conduit Box Style

Directional Control Valves. Features. Application. Operation

Directional Control Valves. General Description. Operation. Features

Directional Control Valves Series D81V. General Description. Operation. Features. Specifications

Operation. D1VW Solenoid Operated Plug-In Conduit Box Style

Directional Control Valves

Série D3 Válvula Direcional CETOP 5 e NG 10. Catálogo HY /US

Directional Control Valves. General Description. Operation. Features

Directional Control Valves. Application. Features. Operation

Directional Control Valves. General Description. Operation. Features

Directional Control Valves. Application. Features. Operation.

Operation. D3W Solenoid Operated Conduit Box Style. D3W Solenoid Operated Hirschmann (DIN) Style

Directional Control Valves. General Description. Features. Specifications

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Directional Control Valves. Application. Features. Operation

Directional Control Valves. Features. Application. Operation

Hydraulics 1. Directional Control Valves Series D1M. Features. Application. Operation. D1MW Solenoid Operated Free Lead Wire

Directional Control Valves. Features. Application. Operation

Directional Control Valves Series D111VW. General Description. Features. Performance Curves

Directional Controls

Direct Operated Proportional DC Valves

Chapter 2: Directional Control Valves

Bulletin HY M6/US Service Bulletin. Series D1VW, H Style 91 Design. Effective: May 1, Directional Control Valves

Bulletin HY M2/US Service Bulletin. Series D1VW, C Style 91 Design. Effective: May 1, Directional Control Valves

Bar 35 PSI 500. Pressure Drop L/M GPM. Flow

Bankable Control Valves

Pilot-Operated Directional Control Valves Series D3 - D11

Directional Control Valves. General Description. Features. Specifications

Directional Control Valve

Pilot Operated Directional Control Valves Series D31DW, D41VW - D111VW

Directional Control Valve Series D1VW

High Pressure, Subplate Mounted Directional Control Valves

Directional Controls

Directional Controls

Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VW

Directional Control Valve Series D3W Soft Shift

Directional Control Valve Series 4D01 (DENISON)

Manapak Sandwich Valves. General Description

High Pressure, Subplate Mounted Directional Control Valves

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1.

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

Directional Control Valve Series D3W (Parker), 4D02 (Denison)

D07 & D08. Series 35 Solenoid Valves D07 D Friendship Drive, Magnolia, TX Tel.: Fax:

Solenoid valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm)

DFE10. solenoid control monoblock valve. Ordering codes. Description example : Diverter valve DFE10/3 A 18 ES - W VDC - SAE - <CVN>

Monobloc and Sectional Directional Control Valves

RA / Accumulator unloading valve, pilot operated, Model DA 6 V.., series 4X. Ordering details DA 6 V 4X. Preferred models 1/8.

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

Directional Control Valves

EManually Operated Directional Valves

"G" SERIES SHOCKLESS TYPE SOLENOID OPERATED DIRECTIONAL VALVES G-DSG-01/03 (1/8, 3/8) "G" SERIES SHOCKLESS TYPE

4/2- and 4/3-Way Proportional Directional Control Valve Direct Operated, Model 4 WRA (Series 1X) PSI (315 bar) H/A 1768

Monobloc and Sectional Directional Control Valves

NG06. General Size NG6 NG10 Design

Pilot Operated Directional Valves

Pump Safety Block Model DBA... / DBAW, Series 1X

Directional Controls

Pressure Control Valves. General Description. Specifications. Ordering Information

3/2 and 4/2 directional seat valves with solenoid actuation

Pilot Operated Directional Control Valves Series D1VP, D3DP, D4P, D9P, D11P

Monobloc and Sectional Directional Control Valves

D03 FluiDyne Valves. ENGINEERING DATA

MDT. Monoblock directional control valves MDT - Directional control valve

EManually Operated Directional Valves

Series Shockless Type Solenoid Controlled Pilot Operated Directional Valves

Pilot Operated Directional Valves

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

Chapter 6: Check Valves

Accessories Series PSB. Specifications

Proportional Valves. Proportional Two-Stage Directional Valves

4/3 and 4/2 on-off directional valve elements D8_5 with or (EDD-XZ) without secondary relief valves and with or without LS connections D8_5 (EDD-XZ)

NG6. Proportional adjustment. Manifold mounting acc. to ISO External drain. Main stage spool type valve. Pilot stage seated type valve.

High Response Type Proportional Electro-Hydraulic Directional and Flow Control Valves

Proportional Directional Valve System

4/3-way high response directional control valve pilot operated with electrical feedback and integrated electronics (OBE)

ANTI-SHOCK DIRECTIONAL CONTROL VALVES

EMechanically Operated Directional Valves

3/2 and 4/2 directional seat valves with solenoid actuation

3/2 and 4/2 directional poppet valve with solenoid actuation

Proportional Directional Control Valves Series D*1FE. General Description. Features. D41FE Standard

Pilot Operated Pressure Relief Valve Series R5V (Denison)

Directional Control Valves

Accessories. Subplates and Connection Plates for Four-Port Directional Valves. Vickers. ISO 4401, 02/03/05/07/08 General Description.

Directional Controls

4/3-4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections

Proportional Pressure Reducing Valve Series D1FV

D05 Directional Control Valves

DRV2-080 Adjustable, Direct-Acting Relief Valve

Pressure Control Valves Series R. General Description. Specifications. Flow Data

VQ1000. How to Order Manifold. Kit type

RA / /3, 4/2 and 3/2-Way Directional Valves Model.WE 10.../.D, Series 3X with Wet Pin DC Solenoids. Functional description, section

Proportional pressure reducing valve of 3-way design

Explosion-Proof Valves. According to Directive 94/9/EC (ATEX) and IECEx Requirements

Monobloc and Sectional Directional Control Valves

p max (see table of performances) Q max (see table of performances) MD1K MD1KD bar

Transcription:

LH Industrial Hydraulic Valves Directional Control, ressure Control, Sandwich, Subplates & Manifolds, ccessories Catalog HY14-2500/US

echnical Information General Description Series D1VW directional control valves are high performance, 4-chamber, direct operated, wet armature solenoid controlled, 3 or 4-way valves. hey are available in 2 or 3-position and conform to NF s D03, CEO 3 mounting patterns. Series D1VW LH Features Soft shift available. 19 standard spool styles available (for other spools Consult Factory). roportional spools. DC surge suppression. Eight electrical connection options. C & DC lights available (CS approval for solenoids and lights). Internally ground. Easy access mounting bolts. Waterproof (meets NEM 4, up to I67 on some models). Explosion proof. CS approvals. Specifications Mounting attern NF D03, CEO 3, NG 6 Mounting DIN 24340-6 Interface ISO 4401--03-4- CEO R35H 4.2-4-03, NF D03 Maximum,, ressure 345 ar (5000 SI) Standard 207 ar (3000 SI) 10 Watt CS 276 ar (3750 SI) ank: 103 ar (1500 SI) C only 207 ar (3000 SI) DC/C Rectified Standard 207 ar (3000 SI) C Optional CS 103 ar (1500 SI) U.L. recognized available - Contact the division. No tools required for coil removal. C rectified coils. Leakage Rates* Maximum llowable: 100 SSU @ 19.7 cc (1.2 Cu. in.) per Minute/Land @ 49 C (120 F) 69 ar (1000 SI)* 73.8 cc (4.5 Cu. in.) per Minute/Land @ 207 ar (3000 SI)* *#008 and #009 ypical: Spools may 4.9 cc (0.3 Cu. in.) per Minute/Land @ exceed these rates. 69 ar (1000 SI)* Consult Factory 26.2 cc (1.6 Cu. in.) per Minute/Land @ 345 ar (5000 SI) Response ime Response time (milliseconds) at 345 ar (5000 SI) is 32 LM (8.5 GM). Solenoid ype ull-in Drop-Out C 13 20 DC 10 Watt 61 22 DC 30 Watt 51 21 Spool Center Condition Orifice Closed Open 2-osition Soft Shift Size Energize De-Energize Energize De-Energize Energize De-Energize S2 0.020 125 ms 920 ms 200 ms 275 ms 51 ms 100 ms S5 0.050 51 ms 675 ms 50 ms 27 ms 51 ms 21 ms 17 Elyria, Ohio, US

Catalog HY14-2500/US Ordering Information D Directional Control Valve 1V NF D03 CEO 3 DIN NG6 Code N V Series D1V asic Valve ctuator Spool Style Seal Solenoid Voltage Code Description W* Solenoid, Wet in, Screw-in HW* Reversed Wiring * Valve schematic symbols are per NF/ NSI standards, providing flow to when energizing solenoid. Note operators reverse sides for #008 and #009 spools. See installation information for details. o configure per DIN standards ( coil over port, coil over port) code valves as D1VHW***. Description Nitrile E* ER Fluorocarbon * Contact HVD for availability. Code Description Code Description ** 24/50 VC Q** 100/60 VC D 120 VDC QD 100/60-100/50 VC G 198 VDC R 24/60 VC J 24 VDC 240/60-220/50 VC K 12 VDC U 98 VDC L 6 VDC Y 120/60-110/50 VC N*** 220/50 VC *** 110/50 VC ** High Watt only Z 250 VDC *** Explosion roof only. vailable in DIN only. LH Code Symbol Code Symbol 001 011 Code Description Symbol * Single solenoid, 2 position, spring offset. b to and to in offset position. 002 014 003 015 004 016 005 020* 006 026* 007 030** 008*, 081 009** 010 082 * 008, 020 & 026 spools have closed crossover. ** 009 & 030 spools have open crossover. C D E F Double solenoid, 3 position, spring centered. Double solenoid, 2 position, detent. Single solenoid, 2 position, spring centered. to and to when energized. Single solenoid, 2 position. Spring offset, energized to center. osition spool spacer on side. to and to in spring offset position. H* Single solenoid, 2 position, spring offset. to and to in offset position. K Single solenoid, 2 position, spring centered. to and to when energized. M Single solenoid, 2 position, spring offset, energized to center position. Spool spacer on side. to and to in spring offset position. * 020, 026 and 030 spools only. 020 and 030 spools only. High Watt only. b b b b a a a a a old: Designates ier I products and options. Non-old: Designates ier II products and options. hese products will have longer lead times. 18 Elyria, Ohio, US

Ordering Information Solenoid Connection Code Description C* Leadwire Conduit ox D** Metric lug (M12X1), DESIN E Explosion roof G lug-in Conduit ox J# Deutsch (D06-2S) M# Metri-ack (150) DIN with lug S# Dual Spade W DIN w/o lug * No variations See lug-in. ** DC only, lights, diode surge suppressor, not CS approved. Not available with lights. Required for variations on conduit box style. Must have lights. # DC only, no lights, not CS approved. Code Omit* D** E** Description High Watt Explosion roof, EEXD EX Explosion roof, EEXME EX F Low Watt L O** 10 Watt Explosion roof, MSH # Explosion roof, Ex d IIC EX/CS U ** Explosion roof, UL/CS Coil Options * C ambient temperature must not exceed 60 C (140 F). ** 60 Hz only on C, no options. C only. DC and C rectified only. # J, K and Y voltages only. Dual frequency on C, no options. Valve Weight: Single Solenoid 1.36 kg (3.0 lbs.) Double Solenoid 1.6 kg (3.5 lbs.) Standard olt Kit: K209 Metric olt Kit: KM209 Seal Kit: Nitrile SKD1VWN91 Fluorocarbon SKD1VWV91 ube Options Manual Override Options Code Omit J** Series D1V Electrical Options Description No Options Diode Surge Suppressor Z Rectified Coil DC tube standard. ** DC only. DIN coil must have plug with lights. Shift Response and Indication Code Description Omit Standard Response S2* Soft Shift, 0.020" Orifice S3* Soft Shift, 0.030" Orifice S4* Soft Shift, 0.040" Orifice S5* Soft Shift, 0.050" Orifice I7** Monitor Switch Direct Op. End Stroke I8** Monitor Switch Direct Op. Start Stroke * Not available with 10 watt. C DIN coil must include plug. ** Single solenoid models only. Not CE or CS approved. Code Omit pprovals Description Standard Valve 3* CS US 4*# CS Canada * Not available with C high pressure tube., C, H styles only. J, K, Y, U voltages only. C, G, W sol. connections only. Conforms to UL429. # Valve is derated. Valve Design Variations Series NOE: Not required when ordering. Code Description Code Description Omit Standard Omit No Variations * No Override 5** Signal Lights * Extended Manual Override w/oot 56* 7* Manaplug (Mini) with Lights Manaplug (Micro) with Lights * Manual override options not available 1C* Manaplug (Mini) Single Sol. 5-pin, on explosion proof or soft shift. with Lights DC/C rectified only. 1D* Manplug (Micro) Single Sol. 5-pin, with Lights 1M* Manaplug Opposite of Normal Code Description 4D wist & Lock Override Omit Standard ressure (Old 5426, 33 Ford wiring) 103.5 ar (1500 SI) C 4E ush Manual Override (Old x5450) 207 ar (3000 SI) DC 4F Heavy Duty Detent H* High ressure, C only 207 ar (3000 SI) 1 ainted ody * Not available with CS. 7Y* 4-pin M12x1 Manaplug, special wiring with lights (Old 755) * lug-in Conduit ox ** lug-in, DIN, or DESIN only DC/C Rectified only. Not available with soft shift. old: Designates ier I products and options. Non-old: Designates ier II products and options. hese products will have longer lead times. LH 19 Elyria, Ohio, US

Catalog HY14-2500/US Dimensions Inch equivalents for millimeter dimensions are shown in (**) DC lug-in Conduit ox Connector, with Lights, Double Solenoid Series D1V LH Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve. DC lug-in or Leadwire Conduit ox Connector, with or without Lights, Single Solenoid Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve. 20 Elyria, Ohio, US

Dimensions Inch equivalents for millimeter dimensions are shown in (**) DC DIN with lug Connector, Double Solenoid Option Shown Series D1V LH DC DIN Connector, Single Solenoid Option Shown Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve. Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve. 21 Elyria, Ohio, US

Catalog HY14-2500/US Dimensions Inch equivalents for millimeter dimensions are shown in (**) C Leadwire Conduit ox Connector, without Lights, Double Solenoid, C Option Series D1V LH Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve. C Leadwire Conduit ox Connector, without Lights, Single Solenoid, C Option Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve. 22 Elyria, Ohio, US

Dimensions Inch equivalents for millimeter dimensions are shown in (**) C lug-in Conduit ox Connector, with Lights, Double Solenoid, G Option Series D1V LH Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve. DC lug-in or Leadwire Conduit ox Connector, with or without Lights and Extended Override ubes, Double Solenoid Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve. 23 Elyria, Ohio, US

Catalog HY14-2500/US Dimensions Inch equivalents for millimeter dimensions are shown in (**) DC Deutsch Connector, Double Solenoid Series D1V LH Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve. DC Deutsch Connector, Single Solenoid Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve. 24 Elyria, Ohio, US

Dimensions Inch equivalents for millimeter dimensions are shown in (**) DC Desina Connector, Double Solenoid Series D1V LH 87.8 (3.46) DC Desina Connector, Single Solenoid Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve. Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve. 25 Elyria, Ohio, US

Catalog HY14-2500/US Dimensions Inch equivalents for millimeter dimensions are shown in (**) Explosion roof, Ex d IIC EX/CS, Double Solenoid Series D1V LH Explosion roof, Ex d IIC EX/CS, Single Solenoid 26 Elyria, Ohio, US

Dimensions Inch equivalents for millimeter dimensions are shown in (**) Explosion roof U.L. & C.S.., Double Solenoid 1/2" N 60.4 (2.38) 163.7 (6.44) Explosion roof M.S.H.., Double Solenoid Series D1V hase Out 130.8 (5.15) 304.4 (11.98) Note: 41.0 mm (1.62") from bottom of bolt hole counterbore to bottom of valve. 18 Inch Lead Wires Standard 94.4 (3.72) 46.0 (1.81) 73.0 (2.87) Note: 2 black wires 1 green wire 15.1 (0.61) 7.5 (0.30) LH 3/4-20 UNF hd. 60.4 (2.38) 163.7 (6.44) 3/4-20 UNF hd. 38.0 (1.50) 113.0 (4.45) 130.8 (5.15) 304.4 (6.44) Note: 41.0 mm (1.62") from bottom of bolt hole counterbore to bottom of valve. Explosion roof, EEXD EX, Double Solenoid 46.0 (1.81) 73.0 (2.87) 15.51 (0.61) 7.5 (0.30) 74.7 (2.94) 69.9 (2.75) 19.4 (0.76) 15.5 (0.61) M20 x 1.5-6H hd. Ground Stud with Lockwasher 100.9 (3.97) 42.8 (1.69) 131.7 (5.19) 100.6 (3.96) 7.5 (0.30) 46.0 (1.81) 73.5 (2.89) 141.0 (5.55) 324.7 (12.78) 27 Elyria, Ohio, US

Catalog HY14-2500/US Dimensions Inch equivalents for millimeter dimensions are shown in (**) Series D1V DC lug-in or Leadwire Conduit ox with Monitor Switch, with or without Lights, Single Solenoid LH Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve. Monitor Switch (Variation I7 and I8) his feature provides for electrical confirmation of the spool shift. his can be used in safety circuits, to assure proper sequencing, etc. Switch Data Inductive switch requiring +18-42 volt input. Outputs and are opposite; one at 0 voltage, the other at input voltage. During switching, and outputs reverse. rovides 0.4 switching current. For repetitive switch power-up conditions, please consult factory. 28 Elyria, Ohio, US

ccessories Manaplug (Options 56 & 1C) Interface rad Harrison lug 3-in for Single Solenoid 5-in for Double Solenoid Ground Wire #1 (Green) Series D1V Micro Connector Options (7 & 1D) LH Solenoid (Negative) Wire #3 (Red/lack) Solenoid (ositive) Wire #2 (Red/White) 3-in Manaplug (Mini) with Lights Single Solenoid Valves Installed Opposite Side of Solenoid ins are as seen on valve (male pin connectors) Conduit ox Option C No Wiring Options vailable Signal Lights (Option 5) lug-in Only LED Interface Meets Nema 4/I67 Hirschmann lug with Lights (Option 5) DESIN Connector (Option D) ISO 4400/DIN 43650 Form in #2 (ositive) Face View of lug in #3 (Ground) in #1 (Negative) M12 pin assignment Standard 1 = Not used 2 = Not used 3 = 0V 4 = Signal (24 V) 5 = Earth Ground ins are as seen on valve (male pin connectors) 1 4 2 DESIN design in 1 and 2 connected 5 3 1 2 3 4 5 29 Elyria, Ohio, US

Catalog HY14-2500/US ccessories Mounting olt Kits Series D1V olt Kits for use with D1V, "E" Explosion roof & Sandwich Valves (D1V*-91, 82 & 70/75 Design, Solenoid Operated & D1V*-72 Design, Non-Solenoid Operated) Number of Sandwich Valves at 44.5mm (1.75") hickness Note: 0 1 2 3 4 Number of Sandwich Valves @40mm (1.58") thickness 0 1 2 3 4 K209 1.25 in. K243 2.88 in. K225 4.38 in. K244 6.00 in. K245 7.50 in. KM209 30 mm KM243 70 mm KM225 110 mm KM244 150 mm KM245 190 mm K246 3.00 in. K247 4.62 in. K248 6.12 in. K249 7.75 in. KM246 75 mm KM247 115 mm KM248 155 mm KM249 195 mm K250 4.75 in. K251 6.38 in. K252 7.88 in. KM250 120 mm KM251 160 mm KM252 200 mm K253 6.50 in. K254 8.12 in. KM102 170 mm KM254 205 mm K103 8.25 in. KM103 210 mm ll bolts are SE Grade 8, 10-24 UNC 2 thread (Metric-M5-0.8) orque to 5.6 Nm (50 in-lb). olt Kits for use with D1V with Explosion roof Coils & Sandwich Valves (D1V*-91, 82 & 70/75 Design) Except "E" Coil LH Number of Sandwich Valves at 44.5mm (1.75") hickness Note: 0 1 2 3 4 Number of Sandwich Valves @40mm (1.58") thickness 0 1 2 3 4 K50 2.00 in. K211 3.63 in. K101 5.12 in. K102 6.75 in. K103 8.25 in. KM50 50 mm KM101 130 mm KM102 170 mm KM103 210 mm K51 3.75 in. K212 5.37 in. K105 6.87 in. K106 7.75 in. KM51 95 mm KM105 180 mm KM106 195 mm K52 5.50 in. K213 7.13 in. K108 8.62 in. KM52 140 mm KM108 220 mm K53 7.25 in. K214 8.87 in. KM53 185 mm K54 9.00 in. KM54 230 mm ll bolts are SE Grade 8, 10-24 UNC 2 thread (Metric-M5-0.8) orque to 5.6 Nm (50 in-lb). Sandwich Valve Dimensional Data ll D03 Sandwich valves (starting with 31 Series) including CM2, COM2, FM2, RDM2 and RM2 measure 40mm (1.58") thickness. For additional technical information about Sandwich valves, refer to the Sandwich Valve Section of this Catalog. 30 Elyria, Ohio, US

echnical Information General Description Series D1V and D1V directional control valves are high performance, 4 and 5-chamber, direct operated, air and oil pilot controlled, 3 or 4-way valves. hey are available in 2 or 3-position and conform to NF s D03, CEO 3 mounting patterns. Series D1V, D1V LH Features Low pilot pressure required. D1V 4.1 ar (60 SI) minimum D1V 15.2 ar (220 SI) minimum ir Operated Shift Volume. he air pilot chamber requires a volume of 1.8 cc (.106 in. 3 ) for complete shift from center to end. ilot iston. he pilot piston area is 506 mm 2 (.785 in. 2 ). ilot piston stroke is 3.4 mm (.135 in.). Response ime. Response time will vary with pilot line size, pilot line length, pilot pressure, air control valve shift time and air valve flow capacity (Cv). Oil Operated Shift Volume. he hydraulic pilot chamber requires a volume of 0.7 cc (.042 in. 3 ) for complete shift from center to end. ilot iston. he hydraulic piston area is 198 mm 2 (.307 in. 2 ). ilot piston stroke is 3.4 mm (.135 in.). Response ime. Response time will vary with pilot line size, pilot line length, pilot pressure, pilot valve shift time and oil valve flow capacity (GM). Specifications Mounting attern NF D03, CEO 3, NG 6 Maximum Operating: 345 ar (5000 SI) ressure ank Line: D1V 34 ar (500 SI) D1V 207 ar (3000 SI) Maximum Flow See Reference Data D1V: ir Minimum 4.1 ar (60 SI) ilot ressure ir Maximum 10.2 ar (150 SI) D1V: Oil Minimum 15.2 ar (220 SI) Oil Maximum 207 ar (3000 SI) Dimensions Inch equivalents for millimeter dimensions are shown in (**) Oil Operated D1V, Single and Double ilot 51.0 (2.00) min. 40.5 (1.60) 42.0 (1.65) 16.9 (0.67) Y 1/4 S (90) or SE #4 15.5 (0.61) 23.0 (0.91) 43.0 (1.70) min. 22.0 (0.87) 9.0 (0.35) See Note 50.0 (1.97) 3.3 (0.13) max. X &Y orts 0.56 (0.022) 127.0 (5.13) 46.0 (1.81) 23.8 (0.94) Note: 22.0 mm (0.87 ) from bottom of bolt hole counterbore to bottom of valve. 31 Elyria, Ohio, US

Catalog HY14-2500/US Ordering Information D Directional Control Valve 1V asic Valve Series D1V ctuator Spool Style Seal Variations Design Series NOE: Not required when ordering. LH NF D03 CEO 3 Oil Operator Code Description Omit Standard 10* Monitor Switch 4F Heavy Duty Detent 90 Shreads * Not available on C and D styles. Not CE or CS approved. Code 001 Symbol Code N V Description Nitrile Fluorocarbon Valve schematic symbols are per NF/NSI standards, providing flow to when energizing operator X. Note operators reverse sides for #008 and #009 spools. See installation information for details. 002 004 008* 009** 020* 026* 030** 081 082 * 008, 020 and 026 spools have closed crossover. ** 009 and 030 spools have open crossover. Code Description Symbol Single operator, two position # spring offset. to and to in offset position. Double operator, C three position, spring centered. D Double operator, two position, detent. wo position, spring centered. E# to and to in shifted position. Single operator, two position, H# spring offset. to and to in offset position. wo position, spring centered. K# to and to in shifted position. # D available with 020 and 030 spools only. & H available with 020, 026 and 030 spools only. E & K not available with 020, 026 and 030 spools. his condition varies with spool code. old: Designates ier I products and options. Valve Weight: 1.90 kg (4.2 lbs.) Standard olt Kit: K209 10 24x1.25 Metric olt Kit: KM209 M5 0.8x30mm Seal Kit: Nitrile SKD1V Fluorocarbon SKD1VV Non-old: Designates ier II products and options. hese products will have longer lead times. 32 Elyria, Ohio, US

Ordering Information D Directional Control Valve 1V asic Valve Series D1V ctuator Spool Style Seal Variations Design Series NOE: Not required when ordering. LH NF D03 CEO 3 ir Operator Code Description Omit Standard 10* Monitor Switch 90 1/4 Shreads * Not available on C & D styles. Not CE or CS approved. Code 001 002 004 008* 009** 081 082 Symbol * 008 spool has closed crossover. ** 009 spool has open crossover. Valve schematic symbols are per NF/ NSI standards, providing flow to when energizing operator. Note operators reverse sides for #008 and #009 spools. See installation information for details. Code N V Description Nitrile Fluorocarbon Code Description Symbol Single operator, two position b spring offset. to and to in offset position. Double operator, b C three position, spring centered. D E H K Double operator, two position, detent. wo position, spring centered. to and to in shifted position. Single operator, two position, spring offset. to and to in offset position. wo position, spring centered. to and to in shifted position. his condition varies with spool code. b b a a a a old: Designates ier I products and options. Valve Weight: 1.60 kg (3.5 lbs.) Standard olt Kit: K209 10 24x1.25 Metric olt Kit: KM209 M5 0.8x30mm Grade 8 bolts required Seal Kit: Nitrile SKD1V Fluorocarbon SKD1VV Non-old: Designates ier II products and options. hese products will have longer lead times. 33 Elyria, Ohio, US

Catalog HY14-2500/US Dimensions Inch equivalents for millimeter dimensions are shown in (**) ir Operated D1V, Double ilot Series D1V LH 61.6 (2.43) 117.8 (4.64) 104.55 (4.12) 1/8 N yp. or 18-28 S 192.5 (7.58) 38.5 (1.52) 51.95 (2.05) 23.8 (0.94) Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve. 23.0 (0.91) 46.0 (1.81) ir Operated D1V, Single ilot Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve. 34 Elyria, Ohio, US

echnical Information General Description Series D1VC, D1VD and D1VG directional control valves are high performance, 4-chamber, direct operated, cam controlled, 4-way valves. hey are available in 2-position and conform to NF s D03, CEO 3 mounting patterns. Features Choice of 2 cam roller positions (D1VC and D1VD) wo styles available (D1VC and D1VG) Short stroke option Specifications Mounting attern NF D03, CEO 3, NG 6 Maximum Operating: 345 ar (5000 SI) ressure ank Line: 34 ar (500 SI) Nominal Flow 32 LM (8.5 GM) Maximum Flow See Reference Data Force Required D1VC, D1VD: 107 N (24 lbs.) to Shift D1VG: 36 N (8 lbs.) Maximum Cam ngle 30 Ordering Information D 1V Series D1VC, D1VD, D1VG LH Directional Control Valve Valve Weight: asic Valve NF D03 CEO 3 Code C D G Description Cam (90 to mounting surface) Cam parallel to mounting surface Cam Lever ype C & D 1.44 kg (3.2 lbs.) ype G 1.6 kg (3.7 lbs.) Standard olt Kit: K209 1 24x1.25 Metric olt Kit: KM209 M5 0.8x30mm Seal Kit: Nitrile SKD1VC Fluorocarbon SKD1VCV ctuator Spool Style Seal Variations Design Code 001 002 004 008* 009 081 Symbol Code N V Description Nitrile Fluorocarbon Code Description Omit Standard 05 Short Stroke 10* Monitor Switch * Not CE or CS approved. Code Description Symbol wo position, spring offset operator at port end. wo position, H spring offset operator at port end. Valve schematic symbols are per NF/ NSI standards, providing flow to when 082 energized. Note flow paths reverse sides for #008 and #009 spools. * 008 spool has closed crossover. 009 spool has open crossover. old: Designates ier I products and options. Series NOE: Not required when ordering. Non-old: Designates ier II products and options. hese products will have longer lead times. 35 Elyria, Ohio, US

Catalog HY14-2500/US Dimensions Inch equivalents for millimeter dimensions are shown in (**) Cam Operated D1VC and D1VD Series D1VC, D1VD, D1VG Full Valve ype re-ravel Spool Over-ravel ravel Standard 2.00 9.06 2.03 Valve (0.079) (0.357) (0.080) 05 0 7.06 4.03 Short Stroke (0) (0.278) (0.159) LH 38.5 (1.52) Over-ravel Full Spool ravel re-ravel 38.4 (1.51) 52.0 (2.05) 23.8 (0.94) Note: For D1VD, Cam Rotated 90 165.9 (6.53) Cam Lever Operated D1VG 23.0 (0.91) Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve. 46.0 (1.81) Full Valve ype re-ravel Spool Over-ravel ravel Standard 6.95 39.63 10.00 Valve (0.27) (1.56) (0.39) 05 0 30.12 18.40 Short Stroke (0) (1.19) (0.72) Over-ravel Full Spool ravel re-ravel 38.5 (1.52) 38.5 (1.52) See Note 79.1 (3.11) 52.0 (2.05) 23.8 (0.94) 209.7 23.0 (0.91) (8.26) 46.0 (1.81) Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve. 36 Elyria, Ohio, US

echnical Information General Description Series D1VL directional control valves are highperformance, 4-chamber, direct operated, lever controlled, 4-way valves. hey are available in 2 or 3-position and conform to NF s D03, CEO 3 mounting patterns. Series D1VL LH Features Spring return or detent styles available Heavy duty handle design Specifications Mounting attern NF D03, CEO 3, NG 6 Maximum Operating: 345 ar (5000 SI) ressure ank Line: 34 ar (500 SI) Maximum Flow See Reference Data Force Required to Shift Lever 25 N (5.6 lbs) Operator Dimensions Inch equivalents for millimeter dimensions are shown in (**) Lever Operated D1VL 85.5 (3.37) 8.9 Full Shift 15.5 (0.61) 15.5 (0.61) 38.6 (1.52) 150.6 (5.93) See Note 46.0 (1.81) 50.0 (1.97) 23.8 (0.94) Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve. 149.5 (5.89) 37 23.0 (0.91) 46.0 (1.81) Elyria, Ohio, US

Catalog HY14-2500/US Ordering Information D Directional Control Valve 1V asic Valve Operator ype and Location Series D1VL Spool Style Seal Variations Design Series NOE: Not required when ordering. LH NF D03 CEO 3 Operator Location ( or ort End) Code Operator ype For Valve Style C D E H K N L Lever (Standard) L Lever (lternate) N/ N/ Code N V Description Nitrile Code Omit Fluorocarbon Description Standard 10* Monitor Switch * Not available on C,D or N styles. Not CE or CS approved. Code 001 002 004 008* 009 081* 082 Symbol * 008 and 081 spools have closed crossover. 009 has open crossover. Code Description Symbol wo position, spring offset. to and to in offset position. C D E H K N hree position, spring centered. wo position, detent. wo position, spring centered. to and to in shifted position. wo position, spring offset. to and to in offset position. wo position, spring centered. to and to in shifted position. hree position, detent. his condition varies with spool code. Valve schematic symbols are per NF/ NSI standards, providing flow to when energizing operator. Note flow paths reverse sides for #008 and #009 spools in three position valves. Valve Weight: 1.60 kg (3.5 lbs.) Standard olt Kit: K209 10 24x1.25 Metric olt Kit: KM209 M5 0.8x30mm Grade 8 bolts required Seal Kit: Nitrile SKD1VL Fluorocarbon SKD1VLV old: Designates ier I products and options. Non-old: Designates ier II products and options. hese products will have longer lead times. 38 Elyria, Ohio, US

Installation Information Fluid Recommendations remium quality hydraulic oil with a viscosity range between 32-54 cst. (150-250 SSU) at 38 C (100 F) is recommended. he absolute operation viscosity range is from 16-220 cst. (80-1000 SSU). Oil should have maximum anti-wear properties and rust and oxidation treatments. Fluids and Seals Valves using synthetic, fire-resistant fluids require special seals. When phosphate ester or its blends are used, FLUOROCRON seals are required. Waterglycol, (95/5) water-in-oil emulsions, and petroleum oil may be used with NIRILE seals. emperature Recommendation Recommended oil temperature: -29 C to +71 C (-20 F to +160 F) mbient temperature: C High Watt ambient temperature cannot exceed 60 C (140 F). DC High Watt, DC Low Watt and C Low Watt ambient temperature cannot exceed 71 C (160 F). Filtration For maximum valve and system component life, the system should be protected at a contamination level not to exceed 125 particles greater than 10 microns per milliliter of fluid. (SE Class 4 or better, ISO Code 16/13). ank Line Surges If several valves are piped with a common tank line, flow surges in the line may cause unexpected spool shift. Detent style valves are most susceptible to this. Separate tank lines should be used when line surges are expected in an application. Recommended Mounting osition Valve ype Detent (Solenoid) Spring Centered Spring Offset Recommended Mounting osition Horizontal Unrestricted Unrestricted Silting Silting can cause any sliding spool valve to stick and not spring return, if held shifted under pressure for long periods of time. he valve should be cycled periodically to prevent sticking. Series D1V Flow ath Data D1V Operator Operator *Note: On valves with 008 or 009 spool, and/or operators reverse sides. Flow paths remain the same as viewed from top of valve. Single ass Operation Valve flow ratings are for double pass operation (with equal flow in both paths). When using these components in single pass applications, flow capabilities may be reduced. Consult your local arker representative for details. Double Solenoid. With solenoid energized, flow path is and. When solenoid is energized, flow path is and. he center condition on a spring-centered valve exists when both coils are de-energized, or during a complete shift, as the spool passes through center. Detent and Spring Offset. he center condition exists on detent and spring offset valves only during spool crossover. o shift and hold a detented spool, only a momentary energizing of the solenoid is necessary. he minimum duration of the signal is approximately 0.1 seconds for DC voltages. his position will be held provided the spool center line is in a horizontal plane, and no shock or vibration is present to displace the spool. Single Solenoid. Spring offset valves can be ordered in styles, E, F, H, K and M. Flow path data for the various styles are described in the order chart. Electrical Failure Should electric power fail, spring offset and spring centered valves will shift to the spring held position. Detented valves will stay in the last position held before power failure. If main flow does not fail or stop simultaneously, machine actuators may continue to function in an undesirable manner or sequence. orque Specifications orque values recommended for the bolts which mount the valve to the manifold or subplate are as follows: #10-24 thread (M5-0.8) torque 5.6 Nm (50 in-lbs). LH 39 Elyria, Ohio, US

Catalog HY14-2500/US Installation Information Mounting attern NF D03, CEO 3, NG 6 Inch equivalents for millimeter dimensions are shown in (**) Series D1V 51.00 (2.000) min. 40.50 (1.594) 33.00 (1.300) M5-0.8 (10-24) UNC-2 thread x 10.40 (.410) min. thread depth 4-holes 0.28 S (0.011) LH 5.10 (0.200) 0.75 (0.030) 21.50 (0.850) 30.20 (1.190) 43.00 (1.70) min. 31.75 (1.250) 31.00 (1.220) 25.90 (1.020) 15.50 (0.610) O 7.5 (.295) max.... & ports 0.56 L (0.022) O 3.86/4.27 (.152/.168) x 4.00 (.160) min. depth 0.28 S (0.011) 12.70 (0.500) 4.80 (0.190) R. max. typ. 4 places 40 Elyria, Ohio, US

echnical Information General Description Series D1SE directional control valves are equipped with a wet pin armature solenoid, drain-free, tapered poppet valve and compatible with the standards DIN NG6, CEO 3, and NF D03. Due to the 3/2 way design, port is either connected with or discharged in the tank. he neutral position (solenoid not activated) is taken automatically by a return spring. his position remains until the solenoid is energized. he valve poppet including activation lever and armature of the solenoid are located in the pressurized oil chamber of connection. he valve poppet is designed such that there can be no differential area in its axial operational direction (opening, closing). hus it is statically pressure-balanced so that the valve can be switched in both flow directions even under pressure. he unit has an all-steel design, the important functional inner parts are hardened, the poppet and seat are ground. Series D1SE Features Low leakage poppet design. Fits NF D03 mountng. ressure balanced. LH Ordering Information D 1 S E W Directional Control Valve asic Valve Seat Valve Wet in rmature Solenoid, Flanged DIN NG6 CEO 3 N D03 Code 30 83 Spool Description Style Seal Solenoid Voltage Solenoid Connection Without lug Code Description K 12V J 24V U* 98V G* 205V Design Series NOE: Not required when ordering. * For alternating current use plug with rectifier. Coils for repair Voltage Ordering Code 12V 7329700-12V 24V 7329700-24V 98V 7329700-98V 205V 7329700-205V Code N V Description Nitrile Fluorocarbon Weight: 0.8 kg (1.76 lbs) old: Designates ier I products and options. Non-old: Designates ier II products and options. hese products will have longer lead times. 41 Elyria, Ohio, US

Catalog HY14-2500/US Specifications General Design Directional poppet valve ctuation Solenoid Size DIN NG6 / CEO 3 / NF D03 Mounting Interface DIN 24340 6 / ISO 4401 / CEO R 121-H / NF D03 Mounting osition Unrestricted mbient -25 C to +50 C (-13 F to +122 F), emperature observe permissible duty cycle Hydraulic Max. Operating 350 ar (5075 SI) (,, and ) ressure Fluid Hydraulic oil in accordance with DIN 51524 / 51525 Fluid emperature -25 C to +70 C (-13 F to +158 F) Viscosity ermitted 10...500 cst / mm²/s (46...2318 SSU) Recommended 30...80 cst / mm²/s (139...371 SSU) Filtration ISO 4406 (1999); 18/16/13 (meet NS 1638: 7) Internal Leakage 3-5 DM per seat Maximum Flow 20 LM (5.28 GM) (at p = 10 bar) Series D1SE Static / Dynamic Step Response Energized: approx. 50 ms De-energized: approx. 60 ms Electrical Characteristics Duty Ratio See Diagram Max. Switching 2000 1/h Frequency rotection Class I 65 in accordance with DIN 40050 (plugged and mounted) Code K J U* G* Supply Voltage 12 VDC 24 VDC 98 VDC 205 VDC olerance Supply ±10% ±10% ±10% ±10% Voltage Current 1.95 1.1 0.25 0.13 Consumption ower Consumption 23.4 W 26.4 W 24.3 W 26.6 W Solenoid Connector as per EN 175301-803 Connection Min. Wiring 3 x 1.5 mm 2 recommended Max. Wiring Length 50m (164') recommended LH * For a silicon bridge rectifier, set up apart from unit for connecting to a 50 or 60 Hz power supply, 110 V~(98=) or 230V~ (205V=). With electrical connections the protective conductor (E ) must be connected according to the relevant regulations. 42 Elyria, Ohio, US

echnical Information erformance Curves ressure Drop SI 290 232 ar 20 16 174 12 116 8 58 4 erformance Curve p-q Series D1SE mbient emperature F 176 158 C 80 70 140 60 122 50 104 40 Duty Cycle vs. mbient emperature LH 0 LM 0 GM 10 2.6 20 5.3 Flow Q 30 7.9 40 10.6 50 13.2 86 30 30 40 50 60 70 80 90 100 Rel. ED % " 5 min. Dimensions Inch equivalents for millimeter dimensions are shown in (**) 58.0 (2.28) Ø 9.0 (0.35) M8 22.0 (0.87) 45.0 (1.77) 62.0 (2.44) 14.0 (0.55) 5.0 (0.20) 35.0 (1.38) 45.0 (1.77) O-ring 9.25 x 1.8 NR 90 Sh Surface Finish Seal K375 4x M5x30 6.8 Nm ± 15% Nitrile: SK-D1SE-70 DIN 912 12.9 Fluorocarbon: SK-D1SE-V70 he space necessary to remove the plug per EN 175301-803, design type F is at least 15 mm. he torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm. 43 Elyria, Ohio, US

Catalog HY14-2500/US Introduction pplication Series D3 hydraulic directional control valves are high performance, direct operated 4-way valves, available in 2 or 3-position. hey are manifold mounted which conform to NF s D05, CEO 5, ISO NG10 mounting patterns. hese valves were designed for industrial and mobile hydraulic applications which require high cycle rates, long life and high efficiency. Operation Series D3 directional control valves consist of a 4-chamber style body, and a case hardened sliding spool. he spool is directly shifted by a variety of operators including: solenoid, lever, cam, or air pilot. Series D3 Features Easy access mounting bolts. 345 ar (5000 SI) pressure rating. Flows to 40 GM depending on spool. Choice of four operator styles. Rugged four land spools. Low pressure drop. hosphate finish body. CS approved and UL recognized available. roportional spool available. LH D3W Solenoid Operated Conduit Cavity Style Wired in cavity. Easy access mounting bolts. 22 spool styles available. hree electrical connection options. C and DC lights available. CS approved. vailable in low-watt DC version. D3W Solenoid Operated Hirschmann (DIN) Style DIN Style (43650) Hirschmann. 22 spool styles available. No tools required for coil removal. Easy coil replacement. C and DC lights available. CS approved. vailable in low-watt DC version. D3.indd, dd 44 Elyria, Ohio, US

Introduction D3L Lever Operated Series D3 LH Spring return or detent styles available. Heavy duty handle design. High flow, low pressure drop design. D3 ir Operated Low pilot pressure required 4.1 ar (60 SI) minimum. High flow, low pressure drop design. D3C Cam Operated Choice of 2 cam roller positions (D3C and D3D). Short stroke option. High flow, low pressure drop design. D3.indd, dd 45 Elyria, Ohio, US

Catalog HY14-2500/US Introduction pplication Series D3DW hydraulic directional control valves are high performance, direct operated 4-way valves, available in 2 or 3-position. hey are manifold mounted which conform to NF s D05, CEO 5, ISO NG10 mounting pattern. hese valves were designed for industrial and mobile hydraulic applications which require high cycle rates, long life and high efficiency. Series D3DW Operation Series D3DW directional control valves consist of a 5-chamber style body, and a case hardened sliding spool. LH D3DW Solenoid Operated Hirschmann (DIN) Style Easy access mounting bolts. No tools required for coil removal. 22 spool styles available. Signal lights available. CS approved. D3.indd, dd 46 Elyria, Ohio, US

echnical Information D3 Spool Reference Data Model Spool Symbol D3W D3W*F D3DW D3*1 150 (40) 78 (20) 130 (33) D3*2 150 (40) 78 (20) 115 (30) D3*3 150 (40) 78 (20) 120 (31) D3*4 150 (40) 59 (15) 130 (33) D3*5 150 (40) 78 (20) 130 (33) D3*6 150 (40) 78 (20) 130 (33) D3*7 50 (13) 59 # (15) 70 (18) D3*8 50 (13) 59 # (15) 39 (10) D3*9 39 (10) 59 # (15) 75 (19) D3*10 115 (30) N/ 75 (19) D3*11 115 (30) 59 # (15) 130 (33) Maximum Flow, LM (GM) 350 ar (5000 SI) w/o Malfunction Series D3 Model Spool Symbol D3W D3W*F D3DW D3*12 95 (24) 59 (15) 75 (19) D3*14 50 (13) 59 # (15) 70 (18) D3*15 150 (40) 78 (20) 120 (31) D3*16 150 (40) 78 (20) 130 (33) D3*20 150 (40) 78 (20) 130 (33) D3*21 115 (30) N/ 120 (31) D3*22 115 (30) N/ 120 (31) D3*26 115 (30) N/ 75 (19) D3*30 39 (10) 59 # (15) 75 (19) D3*81 115 (30) N/ 130 (33) D3*82 115 (30) N/ 130 (33) Maximum Flow, LM (GM) 350 ar (5000 SI) w/o Malfunction LH Center or De-energized position is indicated by,, & port notation. 3000 SI Max. 2900 SI Max. # 1500 SI Max. D3, D3C, D3L Spool Reference Data (Four Chamber ody Only) Model Spool Symbol Maximum Flow, LM (GM) 350 ar (5000 SI) w/o Malfunction Maximum Flow, LM (GM) 350 ar (5000 SI) Model Spool Symbol w/o Malfunction D3*1 150 (40) D3*2 150 (40) D3*4 150 (40) D3*8 50 (13) D3*20 150 (40) D3*26 115 (30) D3*30 39 (10) D3*81 115 (30) D3*9 39 (10) D3*82 115 (30) Center or De-energized position is indicated by,, & port notation. D3.indd, dd 47 Elyria, Ohio, US

Catalog HY14-2500/US erformance Curves D3W-30/32 DC and C Rectified Shift Limits SI ar 5000 345 9, 30 300 4000 Series D3 10, 21, 22, 26 LH Supply ressure 3000 2000 250 200 150 8 7, 14 12 8, 9, 30 11, 81, 82 100 1000 50 0 LM 0 GM 10 20 30 20D, 26D 30D 40 50 60 70 80 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 Flow 1, 2, 3, 4, 5, 6, 15, 16, 20 90 100 110 120 130 140 150 Example: Determine the maximum allowable flow of a D3W Series valve (20D) at 150 ar (2175 SI) supply pressure. Locate the curve marked 20D. t 150 ar (2175 SI) supply pressure, the maximum flow is 98 LM (25 GM). t 345 ar (5000 SI), the flow is 72 LM (18.5 GM). Important Notes for Switching Limit Charts 1. For F & M style valves, reduce flow to 70% of that shown. 2. Shift limits charted for equal flow and ports. Unequal and port flows may reduce shift limits. 3. hese charts do not show explosion proof performance. Consult factory for explosion proof duty. 4. locking and ports will reduce flow to 70% of that shown. D3W-30/32 Low Watt DC and C Rectified Shift Limits SI ar 3000 200 Supply ressure 2000 1000 150 100 50 7, 8, 9 11, 12, 14, 30 4 1, 2, 3, 5, 6, 15, 16, 20 0 LM 0 GM 10 20 30 40 50 60 70 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Flow D3.indd, dd 48 Elyria, Ohio, US

erformance Curves D3W-30/32 C Shift Limits Supply ressure SI 5000 4000 3000 2000 ar 345 300 250 200 150 6 3, 4, 5, 15, 16, 30 1, 3, 4, 5, 15, 16, 20, 30 9 Series D3 11 1, 6, 20 2 12 LH 1000 100 50 7, 8, 14 20D, 30D 0 LM 0 GM 10 20 30 40 50 60 70 80 90 100 110 120 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 Flow D3W-30/32 Soft Shift Limits (High Watt Coil Only) D3.indd, dd Important Notes for Switching Limit Charts 1. For F & M style valves, reduce flow to 70% of that shown. 2. Shift limits charted for equal flow and ports. Unequal and port flows may reduce shift limits. 3. hese charts do not show explosion proof performance. Consult factory for explosion proof duty. 4. locking and ports will reduce flow to 70% of that shown. 49 Elyria, Ohio, US

Catalog HY14-2500/US erformance Curves D3W-30/32 Soft Shift Response Series D3 LH Response ime* Signal to 95% spool stroke measured at 172 ar (2500 SI) and 65 LM (17 GM). Soft Shift Option Energize De-energize S3 400 650 S4 320 550 S7 160 370 * For reference only. Response time varies with flow, pressure and oil viscosity. D3DW-40/41 Shift Limits D3.indd, dd Important Notes for Switching Limit Charts 1. For F & M style valves, reduce flow to 70% of that shown. 2. Shift limits charted for equal flow and ports. Unequal and port flows may reduce shift limits. 3. hese charts do not show explosion proof performance. Consult factory for explosion proof duty. 4. locking and ports will reduce flow to 70% of that shown. 50 Elyria, Ohio, US

echnical Information ressure Drop vs. Flow he table shown provides flow vs. pressure drop curve reference for D3 Series valves by spool type. he chart below demonstrates graphically the performance characteristics of the D3. he low watt coil and other design features of the standard D3W*****F accommodate a maximum flow of 78 LM (20 GM) at 207 ar (3000 SI). Series D3 D3W and D3DW ressure Drop Reference Chart Curve Number Spool Shifted Center Condition No. ( ) ( ) ( ) (-) (-) (-) (-) 1 5 5 2 2 2 4 4 1 1 2 3 3 3 3 1 1 3 5 5 2 3 1 4 4 4 3 3 1 1 5 6 5 2 2 2 6 6 6 2 2 4 4 2 2 7 5 4 2 1 3 3 1 8 8 8 7 7 6 9 5 5 4 4 7 10 5 5 11 5 5 2 2 10 10 12 5 5 2 2 11 10 10 10 10 14 4 5 1 2 3 3 1 15 5 5 3 2 1 16 5 6 2 2 2 20 5 5 2 2 21 5 4 1 9 22 4 5 1 9 26 5 5 30 5 5 2 2 LH erformance Curves Note: For 81 and 82 spools, consult factory. Viscosity Correction Factor Viscosity 75 150 200 250 300 350 400 (SSU) % of 93 111 119 126 132 137 141 (pprox.) Curves were generated using 110 SSU hydraulic oil. For any other viscosity, pressure drop will change per chart. D3.indd, dd 51 Elyria, Ohio, US

Catalog HY14-2500/US Notes LH D3.indd, dd 52 Elyria, Ohio, US

echnical Information General Description Series D3W directional control valves are high-performance, 4-chamber, direct operated, wet armature, solenoid controlled, 3 or 4-way valves. hey are available in 2 or 3-position and conform to NF s D05, CEO 5 mounting patterns. Series D3W LH Features Worldwide, high flow, low pressure drop design. Soft shift available. 22 spools available including proportional. DC surge suppression available to protect electrical equipment. hree electrical connection options. C & DC lights available. Easy access mounting bolts. Explosion proof availability. CS approved. No tools required for coil removal. Rectified coils available for high flow C applications. Response ime (ms) Signal to 95% spool stroke measured at 172 ar (2500 SI) and 75 LM (20 GM) Solenoid ype m sec C Energize 21 C De-energize 35 DC Energize 110 DC De-energize 85 Specifications Interface NF D05, CEO 5, NG 10 Max. Operating,, : ressure 345 ar (5000 SI) Standard CS File Number CS 207 ar (3000 SI) ank: 103 ar (1500 SI) C Standard 207 ar (3000 SI) C Optional DC/C Rectified Standard CS LR060407 103 ar (1500 SI) Leakage Rates Maximum llowable: 100 SSU @ 19.6 cc (0.38 Cu. in.) per Minute/ 49 C (120 F) Land @ 69 ar (1000 SI)* 35 cc (2.19 Cu. in.) per Minute/ Land @ 207 ar (3000 SI)* * #008 and #009 Spools may exceed these rates, consult factory D3.indd, dd 53 Elyria, Ohio, US

Catalog HY14-2500/US Ordering Information D 3 Directional Control Valve W Series D3W asic Valve ctuator Spool Style Seal Solenoid Voltage LH NF D05 CEO 5 NG 10 Wet armature solenoid Code Symbol Code Symbol 1 14 Code N V Description Nitrile Fluorocarbon Code Description E# 24/60-24/50 VC Y 120/60-110/50 VC 240/60-220/50 VC K 12 VDC J 24 VDC D# 120 VDC U# 98 VDC Z# 250 VDC # High Watt Coil only. 2 15 3 16 4 20* 5 21 6 22 7 26* 8* 30** 9** 10 81 11 82 12 * 8, 20 & 26 spools have closed crossover. ** 9 & 30 spools have open crossover. vailable only with high-watt rectified C coils or high-watt DC coils. Spring centered versions C, E, F, K & M only. Code Description Symbol Single solenoid, 2 position, * spring offset. to and to in offset position C Double solenoid, 3 position, spring centered. D Double solenoid, 2 position, detent Single solenoid, 2 position, E spring centered. to and to when energized. Single solenoid, 2 position. Spring offset, F** energized to center position. Spool spacer on side. to and to in spring offset position. Single solenoid, 2 position, H* spring offset. to and to in offset position. Single solenoid, 2 position. K Spring centered. to and to when energized. Single solenoid, 2 position, spring offset, energized M** to center position. Spool spacer on side. to and to in spring offset position. * Only spools 20, 26 & 30. ** High Watt Coil. Only spools 20 & 30. his condition varies with spool code. b b b b b a a a a a Valve schematic symbols are per NF/NSI standards, providing flow to when energizing solenoid. Note operators reverse sides for #8 and #9 spools. See installation information for details. old: Designates ier I products and options. D3.indd, dd Non-old: Designates ier II products and options. hese products will have longer lead times. 54 Elyria, Ohio, US

Ordering Information Solenoid Connection Code C** K J#* Description Conduit Cavity Conduit ox Deutsch (D06-2S) Hirschmann w/lug W* Hirschmann w/o lug E* Explosion roof * Lights not available. ** No variations (See K ). # DC voltage only. Solenoid/ube Options Manual Override Options Code Description Omit Standard ube * Extended Manual Override * Not available with soft shift or explosion proof. Series D3W Electrical Options Shift Response and Indication Code Omit pprovals Description Standard Valve 3* CS US (UL429) 4* CS Canada * Not available with C high pressure tube., C, H styles only. Y voltage with conduit connection only, must be rectified. Variations Design Series NOE: Not required when ordering. LH Options Coil ube Rating C DC/C Rectified Omit High Watt 103.5 ar (1500 SI) 207 ar (3000 SI) F*# Low Watt n/a 207 ar (3000 SI) H High Watt 207 ar (3000 SI) n/a D Explosion roof, EEXD EX U Explosion roof, UL/CS * vailable only with J, K and Y (Rectified), (Rectified) voltages. # Not available with soft shift or with F and M style valves. Explosion proof coils are 60 Hz at standard voltage; dual rating not available. Valve Weight: Single Solenoid: C 4.3 kg (9.5 lbs.) DC 5.3 kg (11.6 lbs.) Double Solenoid: C 5.0 kg (11.0 lbs.) DC 7.3 kg (16.0 lbs.) Seal Kit: Nitrile SKD3W Fluorocarbon SKD3WV Mounting olt Kits UNC olt Kits for use with D3W & Sandwich Valves Number of Sandwich Valves @ 2.00 (50mm) thickness 0 1 2 3 D3W Standard: K98 K141 K142 K143 1.62 3.50 5.50 7.50 Metric: KM98 KM141 KM142 KM143 40mm 90mm 140mm 190mm D3W with Standard: K144 K61 K62 K63 explosion 2.37 4.25 6.25 8.25 proof coils Metric: KM144 KM61 KM62 KM63 60mm 110mm 160mm 210mm NOE: ll bolts are SE grade 8, 1/4-20 UNC-2 thread, torque to 16 Nm (12 ft-lbs) Code Description Omit No Option V# Varistor Surge Suppressor Z C Rectified with MOV Surge Suppressor # DC voltage only. Code Omit S3** S4** S7** Description Standard Valve Soft Shift, 0.030 Orifice Soft Shift, 0.040 Orifice Soft Shift, 0.070 Orifice I7* Monitor Switch Direct Op. End Stroke I8* Monitor Switch * Single solenoid models only. Not CE or CS approved. Spools 8, 9, 81 & 82 not available. ** High watt coil only. Code Description Omit Standard Valve 5 Signal Lights 6 Manaplug, rad Harrison Mini 7 Manaplug, rad Harrison Micro (M12x1) 56 Manaplug (Mini) with Lights 57 Manaplug (Micro) with Lights (M12x1) 1 Manaplug (Mini) Single Sol. 5-in 1 Manaplug (Micro) Single Sol. 5-in (M12x1) 1C Manaplug (Mini) Single Sol. 5-in w/lights 1D Manaplug (Micro) Single Sol. 5-in w/lights (M12x1) 1M Manaplug Opposite Normal D3.indd, dd old: Designates ier I products and options. Non-old: Designates ier II products and options. hese products will have longer lead times. 55 Elyria, Ohio, US

Catalog HY14-2500/US echnical Information Solenoid Ratings** Insulation Class H llowable Deviation DC, C Rect -10% to +15% from rated voltage C -5% to +5% rmature Wet pin type ** DC Solenoids available with optional molded metal oxide varistor (MOV) for surge suppression. Leadwire length 6 from coil face. Series D3W D3W*****F Solenoid Electrical Characteristics Solenoid Nominal In Rush Holding Code Volts/Hz mps mps Watts KF 12 VDC 1.50 18 JF 24 VDC 0.75 18 ased on nominal voltage @ 22 C (72 F) LH D3W Solenoid Electrical Characteristics Solenoid Nominal In Rush Holding Nominal Code Volts/Hz V V Watts (Ref) Y 120/60 298 95 32 110/50 294 102 240/60 288 96 32 220/50 288 101 E 24/60 290 77 32 24/50 381 110 K 12 VDC 3.00 36 J 24 VDC 1.50 36 D 120 VDC 0.30 36 U 98 VDC 0.37 36 Z 250 VDC 0.14 36 D3W Rectified C Solenoid Electrical Characteristics Solenoid Nominal In Rush Holding Code Volts/Hz mps mps Watts Y 120/60.37 36 110/50 240/60.18 36 220/50 YF 120/60.18 18 110/50 F 240/60.09 18 220/50 ased on nominal voltage @ 22 C (72 F) DC holding amps. Explosion roof Solenoids Explosion roof Solenoid Ratings Electrical Characteristics* ED and EU U.L. /CS (EU) EX Class I, Div. 1 & 2, Groups C & D Class II, Div 1 & 2, Groups E, F & G s defined by the N.E.C. Complies with EX requirements for: Exd, Group II; EN50014: 1999+ mds 1 & 2, EN50018: 200 Solenoid Nominal In Rush Holding Nominal Code Volts/Hz V V Watts (Ref) Y 120/60 266 82 36 240/60 266 82 36 K 12 VDC 3.00 36 J 24 VDC 1.50 36 D 120 VDC 0.30 36 * Dual frequency not available on explosion proof coils. DC holding amps. D3.indd, dd 56 Elyria, Ohio, US

Dimensions Inch equivalents for millimeter dimensions are shown in (**) Hirschmann, Double C Solenoid Series D3W LH Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve. Hirschmann, Single C Solenoid Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve. D3.indd, dd 57 Elyria, Ohio, US

Catalog HY14-2500/US Dimensions Inch equivalents for millimeter dimensions are shown in (**) Conduit Cavity, Double DC Solenoid Series D3W LH Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve. Conduit Cavity, Single DC Solenoid Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve. D3.indd, dd 58 Elyria, Ohio, US

Dimensions Inch equivalents for millimeter dimensions are shown in (**) Series D3W Conduit ox, Single C Solenoid with Variation 6 (Manaplug) & Variation (Extended Manual Override) LH Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve. Conduit ox, Double DC Solenoid with Variation 6 (Manaplug) & Variation (Extended Manual Override) Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve. D3.indd, dd 59 Elyria, Ohio, US

Catalog HY14-2500/US Dimensions Inch equivalents for millimeter dimensions are shown in (**) Explosion roof U.L. & CS, Double Solenoid Series D3W LH Note: Mounting bolts included with valve. Explosion roof EX, Double Solenoid M20 x 1.5-6H Metric hread olthole Centerline Reference Ground Stud 134.7 (5.31) 103.6 (4.08) 36.0 (1.42) 18.9 (0.74) Ref. 18.9 (0.74) 11.6 (0.46) 23.0 olthole 23.0 (0.91) 12.1 Centerline (0.91) 58.1 (0.47) Reference 75.6 (2.98) (2.29) 154.1 (6.07) Note: Mounting bolts included with valve. D3.indd, dd 60 11.3 (0.44) 76.7 (3.02) 64.9 (2.56) 207.7 (8.18) Elyria, Ohio, US

Dimensions Inch equivalents for millimeter dimensions are shown in (**) Hirschmann, Single C Solenoid with Variation I7 (Monitor Switch) Series D3W LH Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve. Monitor Switch (Variation I7) End of Stroke his feature provides for electrical confirmation of the spool shift. his can be used in safety circuits, to assure proper sequencing, etc. Switch Data Inductive switch requiring +18-42 volt input. Outputs and are opposite; one at 0 voltage, the other at input voltage. During switching, and outputs reverse. rovides 0.4 switching current. For repetitive switch power-up conditions, please consult factory. D3.indd, dd 61 Elyria, Ohio, US

Catalog HY14-2500/US ccessories Conduit ox (connection option K) Interface 152.4 cm (6.0 inch) lead wires, 18 awg. Meets NEM 4 and I65 Series D3W LH Manaplug (valve variations 6, 56, 1, 1C) Interface rad Harrison lug 3-in for Single Solenoid 5-in for Double Solenoid Ground Wire #1 (Green) Solenoid (Negative) Wire #3 (Red/lack) Solenoid (ositive) Wire #2 (Red/White) 3-in Manaplug (Mini) with Lights Single Solenoid Valves Installed Opposite Side of Solenoid ins are as seen on valve (male pin connectors) Hirschmann lug with Lights (5) Manaplug - Micro Connector (valve variations 7, 57, 1, 1D) in #3 (Ground) in #2 (ositive) in #1 (Negative) Face View of lug Conforms to DIN43650, ISO4400, Form 3-in ins are as seen on valve (male pin connectors) D3.indd, dd 62 Elyria, Ohio, US

echnical Information General Description Series D3DW directional control valves are high performance, 5-chamber, direct operated, wet armature, solenoid controlled, 3 or 4-way valves. hey are available in 2 or 3-position and conform to NF s D05, CEO 5 mounting patterns. Series D3DW LH Features 22 spools available including proportional. DC surge suppression available to protect electrical equipment. Easy access mounting bolts. CS approved. No tools required for coil removal. High pressure tank line capability. Monitor switch available. Response ime (ms) Signal to 95% spool stroke measured at 175 ar (2500 SI) and 75 LM (20 GM) Solenoid ype ull-in Drop-Out DC 110 85 Solenoid Ratings** Insulation Class H llowable Deviation DC only from rated voltage -10% to +15% rmature Wet pin type ** DC Solenoids available with optional molded metal oxide varistor (MOV) for surge suppression. D3DW Solenoid Electrical Characteristics Solenoid Nominal In Rush Holding Nominal Code Volts mps mps Watts (Ref) K 12 VDC 3.00 36 J 24 VDC 1.50 36 D 120 VDC 0.30 36 Y* 120/60 0.37 36 110/50 * 240/60 0.18 36 220/50 * C input rectified to DC Specifications Interface NF D05, CEO 5, NG 10 Max. Operating,, : ressure 345 ar (5000 SI) Standard Maximum Flow CS 207 ar (3000 SI) ank: 207 ar (3000 SI) Standard CS 103 ar (1500 SI) See Spool Reference Chart Leakage Rates Maximum llowable: 100 SSU @ 19.7 cc (1.2 Cu. in.) per Minute/ 49 C (120 F) Land @ 69 ar (1000 SI)* 73.8 cc (4.5 Cu. in.) per Minute/ Land @ 207 ar (3000 SI)* ypical: 4.9 cc (0.3 Cu. in.) per Minute/ Land @ 69 ar (1000 SI)* 26.2 cc (1.6 Cu. in.) per Minute/ Land @ 345 ar (5000 SI) * #008 and #009 Spools may exceed these rates, consult factory. D3.indd, dd 63 Elyria, Ohio, US