Solenoid Actuated Diesel Engine Air Shut Down Valves

Similar documents
SVX-Series Solenoid Actuated Diesel Engine Air Shut Down Valves (Energised to Run, Hazardous Area Types without Manual Override)

SVX-Series Diesel Engine Shut Down Valves (Solenoid Latched Types with Manual Start Override/Emergency Stop)

SVX-Series Solenoid Actuated Diesel Air Shut Down Valves

Diesel Engine Shutdown Valves

MVX-Series Diesel Engine Air Shut Down Valves

HVX-Series Diesel Engine Shut Down Valves (Oil Pressure Latched Types with Manual Start Override/Emergency Stop)

SVX-Series Solenoid Actuated Diesel Engine Air Shut Down Valves (Energised to Run Types for Non-Hazardous Areas)

Diesel Engine Shutdown Valve

SVX-Series Solenoid Actuated Diesel Engine Air Shut Down Valves (Energised to Stop Types)

MPX-Series Diesel Engine Shut Down Valves (Manual Reset / Air Pressure and Manual Closure Options)

D-Series Automatic Engine Overspeed Shut Down Valves (Bendix Types)

Diesel Engine Shutdown System

Flameproof Alternators

FS2 Valves. Solenoid Powered to Close / Auto Reset Butterfly Valves

FS3 Valves. Solenoid Powered to Open / Spring to Close (failsafe)

SELECTION, APPLICATION AND MAINTENANCE

D200 Spindle Type Automatic Engine Overspeed Air Intake Shut Down Valve (including Manual, Oil and Air Pressure Shut Down Control options)

D-Series Automatic Engine Overspeed Shut Down Valves (Bendix Types)

Air Intake Shut-off Valve

Diesel Engine Safety Solutions. Automatic Engine Overspeed Shut Down Valves - D Series

System Selection Guide

World class manufacturer of safety solutions SYSTEM SELECTION GUIDE. Safety solutions for vehicles and machines working in petrochemical plants

Automatic Fuel Shut Down Valves

D-Series Automatic Engine Overspeed Shut Down Valves (Mini Range)

Intake Air Shut-off Valve

Diesel Engine Air Intake Shutoff Valves

SELECTION, APPLICATION AND MAINTENANCE

RODADEACO. Diesel Engine Air Intake Shutoff Valves. Model RDB3 Compact Butterfly Valve. by AMOT. Overview. Typical Applications

E Series. Automatic Engine Overspeed Shut Down Valves

SELECTION, APPLICATION AND MAINTENANCE

E-M Series. Combined Manual and Automatic Engine Overspeed Shut Down Valves

Model 4418F. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve

Flameproof Alternator

Model 4418F. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve

Flameproof Alternator

by AMOT World class diesel engine safety solutions Automatic Engine Overspeed Shut Down Valves - D Series

Thermostatic Valve. Filterstat - Model FJA. Typical applications. Key features and benefits. Mixing Diverting

Pressure and Temperature Switches

Self-Exciting Flameproof Alternator

Flameproof Alternator

by AMOT World class diesel engine safety solutions Product Selection Guide

Optimise your temperature control

Pilot Operated 2-Way Gas Valves

Pneumatic Indicating Relay

2-Way Temperature Sensing Valves

Metal Particle Detector

Model J. Thermostatic Control Valves. Typical applications. Key benefits. Key features. Accreditations available

Model H. Thermostatic Control Valves. Typical applications. Key benefits. Key features. Accreditations

Is the heart of your engine protected?

Thermostatic Control Valves

PH1 AIR INTAKE EMERGENCY SHUT-OFF VALVE PULL CABLE ACTUATION.

Thermostatic Valve. Filterstat - Model FJA. Typical applications. Key features and benefits. Mixing Diverting

3-Way Temperature Control Valve

C50254A PH3 AIR INTAKE SHUT-OFF VALVE DODGE 6.7L CUMMINS WITH POWERGUARD SMART OVERSPEED LIMITER

AIR INTAKE EMERGENCY SHUT-OFF VALVE PH2 C50204 AIR INTAKE SHUT-OFF VALVE DODGE 6.7L CUMMINS.

PH2 C50219A AIR INTAKE SHUT-OFF VALVE. T800 KENWORTH / ISX ENGINE WITH POWERGUARD SMART OVERSPEED LIMITER

PH3 AIR INTAKE EMERGENCY SHUT-OFF VALVE WITH POWERGUARD SMART OVERSPEED LIMITER. Generic PH3 Truck Shut-Off Valve Kit.

Thermostatic Control Valve

AIR INTAKE EMERGENCY SHUT-OFF VALVE C50203 AIR INTAKE SHUT-OFF VALVES APPLICATION DODGE 5.9L CUMMINS.

PH2 POWERHALT AIR INTAKE SHUT-OFF VALVE C50201A ½ DODGE 6.7L CUMMINS C50202A DODGE 6.

Thermostatic Control Valve

Series 500. Liquid Level Transmitters. Instruction Manual

SERIES 2000 GAS SAFETY SHUT OFF VALVE

Model E. Thermostatic Control Valves. Typical applications

PH2 AIR INTAKE EMERGENCY SHUT-OFF VALVES. APPLICATION C ½ DODGE 6.7L CUMMINS C DODGE 6.

Metal Particle Detector

Installation Instructions. Standard Gate Valves

1410 Series & 4413 / 4423 Series Intrinsically Safe Solenoid Operated Directional Control Valves & Pilot Valves for Marine Applications

Black Teknigas. Powerseat Eco Gas Safety Shut-Off Valve. Technical, Installation and Maintenance Details. WattsIndustries.co.uk

Service Manual for Battery Control Center

E1186X Breather Kit. For Yanmar L48N Engines

AIR INTAKE EMERGENCY SHUT-OFF VALVE C50207 AIR INTAKE SHUT-OFF VALVES APPLICATION FORD 6.7L POWERSTROKE.

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

fact sheet Masoneilan * 8007/8008 Series Electro-pneumatic Transducers GE Energy Nozzle Design Reducing Effects of Vibration Overview

ELECTRIC ACTUATOR MOD. VB015 MAINTENANCE AND INSTALLATION INSTRUCTIONS OF VALBIA ELECTRIC ACTUATORS

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

EMK-XP ElectroMelt Power Connection and End Seal Kit Installation Instructions

II 2GD. xxxx. Westlock 2200 Series Quantum - ATEX certified Installation & Operating Instructions

OCTOPUS SELECTION & INSTALLATION GUIDE Rev. C CRA SERIES CONTINUOUS RUNNING PUMPSET

Installation, Operation and Maintenance Manual DOC.IOM.MO.E October MO-Series Manual Override Gearboxes

Installation Instructions

Rosemount 585 Annubar Flanged Flo-Tap Assembly

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

EXPLOSION PROOF DIRECTIONAL CONTROL VALVE TYPE ED6 SERIE 5X CENELEC STANDARD & ATEX DIRECTIVE

Series 810: 2 Way Angle Body Valves: 1/4 to 3 NPT

JAMESBURY EASYFLOW JT SERIES ANGLE STEM TANK BOTTOM VALVES

M High Performance Power Transmission Couplings

Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black

Quarter turn actuators Index

Power-Limiting Cables

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Solar Thermal. Grant Solar Pump Station Installation & Servicing Instructions

Electrically Operated Pressure Relief Cartridge, Size 1 Seated Design, Direct Acting Series WUVA 1LO...

Rosemount 485 Annubar Threaded Flo-Tap Assembly

B21 Series BASOTROL Gas Valve

Transfer switch GTEC open or delayed transition

INSTALLATION AND MAINTENANCE

2/2 Pressure operated valves

ABV21i and ABV40i Air Actuated Boiler Blowdown Valves

INSTALLATION, OPERATION & MAINTENANCE MANUAL MODEL BC.

Transcription:

SVX-Series Solenoid Actuated Diesel Engine Air Shut Down Valves (Energised to Run, Hazardous Area Types without Manual Override) Selection, Application and Maintenance DS-SVX320-830-SolenoidValves-CE239-0712-rev1

Description A range of 12 and 24 volt EExe solenoid operated diesel engine air intake closure valves based on the standard Chalwyn slimfit 3, 5 and 8 butterfly valves. These products are available in basic flange mounted form, but can also be supplied fitted with hose adaptors. These valves are designed to fail safe in that if electrical power is lost for any reason the valve will revert to the closed condition. Valve bodies and discs are all manufactured from corrosion resistant hard anodised aluminium with a PTFE coating. Spindles and mechanisms are manufactured from 316 stainless steel. The Chalwyn 12 volt solenoid type SSX-102 built into the hazardous area valves type SVX-320, SVX-520 and SVX-820 is marked as follows: CHALWYN by AMOT Bury St Edmunds, UK TYPE SSX-102 EEx e II T4 (Tamb = -30 c to +50 c) 0518 11 2 G D IP66 SIRA99ATEX3186X SERIAL NO. xxxxx 12 VOLTS, HOLD 1.1A PULL 46A The Chalwyn 24 volt solenoid type SSX-201 built into the hazardous area valves type SVX-330, SVX-530 and SVX-830 is marked as follows: CHALWYN by AMOT Bury St Edmunds, UK TYPE SSX-201 EEx e II T4 (Tamb = -30 c to +50 c) 0518 11 2 G D IP66 SIRA99ATEX3186X SERIAL NO. xxxxx 24 VOLTS, HOLD 0.5A PULL 25A IMPORTANT NOTES: SOLENOID TYPES SSX-102 AND SSX-201 Araldite epoxy adhesive and an elastomeric cable seal are used in the construction of these solenoids. The characteristics of these materials with regard to attack by aggressive substances shall be taken into account when installing or using the product in a hazardous area. Solenoids SSX-102 and SSX-201 must not be mounted or installed in such a way that the effective ambient temperature exceeds 50 c. page 2

Typical Valve Arrangement B Alternative Cable Gland Position Cable Gland Optional Hose Adapter Range C 1 C 2 (Min) C 2 (Max) D A Main Dimensions (mm) Valve Type SVX-320 SVX-330 SVX-520 SVX-530 SVX-820 SVX-830 Nominal Bore Dia. 76 (3 ) 127 (5 ) 203 (8 ) For optional hose adaptor range see page 4. A 161.0 217.0 317.5 B 111.5 167.5 257.0 C 1 37.5 45.5 56.0 C 2 (min & max) 82.5 to 112.5 102.0 to 157.5 136.5 to 185.5 D 121.5 125.5 130.5 page 3

Selection This range of valves is suitable for operation in T4, Zone 1, Gas Group IIB or in Zone 21 hazardous areas. All valves in this range have separate connections for pull and hold coils. The power supply must therefore be arranged with a suitable timer circuit to switch between the pull and hold connections. Determine the size and position of the SVX valve to be installed. Within the various constraints imposed by the application, the valve should be as generously sized as possible. Check that the valve can be installed such that the electrical cable may be routed away without risk of damage. The standard cable gland entry point is shown on page 3. An alternative end entry position is available if specified. If the valve is to be fitted into a hose as opposed to flange mounted, suitable hose adaptors should be selected from the table below and ordered with the valve. Hose Adaptor Options 76mm (3 ) Bore Valves Adaptor To Suit Hose Bore Part Number mm (inches) HAX-320 38 ( 1 1 / 2 ) HAX-322 44.5 (1 3 / 4 ) HAX-301 51 (2) HAX-303 57 (2 1 / 4 ) HAX-304 60 (2 3 / 8 ) HAX-305 63.5 (2 1 / 2 ) HAX-306 67 (2 5 / 8 ) HAX-307 70 (2 3 / 4 ) HAX-309 76 (3) HAX-312 82.5 (3 1 / 4 ) HAX-314 89 (3 1 / 2 ) HAX-319 102 (4) 127mm (5 ) Bore Valves Adaptor To Suit Hose Bore Part Number mm (inches) HAX-501 89 (3 1 / 2 ) HAX-503 95 (3 3 / 4 ) HAX-505 102 (4) HAX-507 108 (4 1 / 4 ) HAX-509 114 (4 1 / 2 ) HAX-511 121 (4 3 / 4 ) HAX-513 127 (5) HAX-518 140 (5 1 / 2 ) HAX-523 152 (6) 203mm (8 ) Bore Valves Adaptor To Suit Hose Bore Part Number mm (inches) HAX-807 178 (7) HAX-808 203 (8) page 4

Installation (Mechanical) 1. In the case of a naturally aspirated engine, the Chalwyn SVX shut down valve should generally be fitted as close to the engine air intake manifold as possible. If an air intake flame trap is also fitted, the SVX valve must be installed upstream (air cleaner side) of the flame trap. 2. If the engine is turbocharged, it may be necessary to fit the valve upstream of the turbocharger in order to avoid temperatures in excess of the maximum permitted for the solenoid (see page 2). Again if an air intake flametrap is also fitted the valve must be installed upstream of the flametrap. 3. Where more than one SVX valve is installed on an engine, as in the case of an engine with multiple intake pipes, the shut down valve control system must be arranged to ensure all valves close simultaneously. 4. This valve may be installed either horizontally or vertically. 5. If hose adaptors are used, the mating hose should be of a reinforced type, provide adequate support for the valve and prevent excessive vibration. If necessary, additional support brackets mounted from the engine should be considered. 6. Particular care must be taken to ensure the integrity of the intake pipework between the Chalwyn valve and intake manifold. Ideally metal pipework should be used and any gaps kept as short as possible, (taking into account any relative movement) and closed by reinforced hose. 7. Any engine crankcase breather connections into the intake system between the SVX valve and engine, or any internal crankcase breather arrangement venting directly into the engine intake ports must be sealed and replaced by an external breather system venting either to atmosphere or to the intake system upstream of the shut down valve. External breather system kits for various engine types are available from Chalwyn. Installation (Electrical) The diagram shows a typical Chalwyn wiring arrangement for the solenoids. It is IMPORTANT that the start key switch for the engine is wired such that between starting attempts it is not necessary to de-energise the solenoid. The starting instructions for the operative must clearly state that the key switch should not be returned to the solenoid de-energised position whilst attempting to start. If this requirement cannot be complied with, or if the engine is an unattended unit fitted with an automatic start arrangement, the control system providing the power to the solenoid must be designed to restrict the number of times the pull coil is energised to a maximum of 6 times per 30 minutes followed by a 30 minute rest before repeating the cycle. D+ THERMAL CIRCUIT BREAKER D+ THERMAL CIRCUIT BREAKER + 12V 50A CONTROL BOARD 2 1 5 3 + 12V 50A 2 1 5 3 D- D- AIR INTAKE VALVE SOLENOID HOLD PULL 0V HOLD PULL 0V FUEL VALVE SOLENOID Supply voltage: 12 vdc. (SVX-320, SVX-520 and SVX-820) or 24vdc (SVX-330, SVX-530 and SVX-830 Pull current at 23 C : 46 amps (12 volt types) or 25 amps (24 volt types). Hold current at 23 C : 1.1 amps (12 volt types) or 0.5 amps (24 volt types). Pull coil: Must not be powered for more than 0.5 seconds continuously. A suitable timer circuit must be incorporated to achieve this. NOTE: The control system must include a backup safety device which de-energises the pull coil if it is energised for more than 14 seconds continuously. The blue wire is the common return and must be connected to the negative terminal of the supply. Example of a typical solenoid operating circuit The yellow/green wire is the pull coil supply. The brown wire is the hold coil supply. The outer braiding of the supply cable should be earthed at the supply end. The solenoid may be earthed using the earth tag of the cable gland. NOTE: a) Suitable cable glanding must be used at the supply end of the cable. b) The length of the supply cable should not be increased from that supplied. page 5

Operation When powered the solenoid holds the air intake shut down valve in the open (engine run) condition. On loss of power the spring within the shut down valve assembly moves the valve to the closed (engine stop) position, i.e. failure of power supply gives a fail safe (engine stopped) condition. Maintenance WEEKLY: Visually check the valve, solenoid, cable and cable gland for damage or deterioration. Withdraw from service if significant damage or deterioration is observed. NOTE: Chalwyn hazardous area solenoids are sealed units. The cable gland must not be loosened or removed. If a service problem occurs, the valve should be returned to Chalwyn for repair. MONTHLY: Check that the fasteners locating the shut down valve and any associated intake system or support bracket fasteners are securely tightened. Check that any flexible hoses in the engine intake between the SVX valve and engine are free from damage and suitable for further service. Run engine, preferably at low idle. Use shut down control system emergency stop to close the intake shut down valve. The engine should stop within a few seconds. If not, check there are no leaks in the engine air intake system between the SVX valve and engine. If this does not resolve the problem remove the SVX valve to return to Chalwyn for investigation. page 6

NOTES: Solenoid Actuated Diesel Engine Air Shut Down Valves page 7

Solenoid Actuated Diesel Engine Air Shut Down Valves Americas Asia Pacific Europe, Middle East and Africa AMOT - USA Tel: +1 281 940 1800 Fax: +1 713 559 9419 info@amotusa.com AMOT - China Tel: +86 (0)21 6279 7700 Fax: +86 (0)21 5237 8560 shanghai@amot.com AMOT - UK Tel: +44 (0)1284 715739 Fax: +44 (0)1284 715747 info@amot.com Roda Deaco by AMOT - Canada Tel: +1 780 465 4429 Fax: +1 780 469 6275 info@rodadeaco.com AMOT - Singapore Tel: +65 6408 6265 Fax: +65 6408 6266 singapore@amot.com AMOT - Germany Tel: +49 (0)40 8537 1298 Fax: +49 (0)40 8537 1331 germany@amot.com AMOT - Russia Tel: +7 495 617 12 96 Fax: +7 495 913 97 65 russia@amot.com Chalwyn's quality management page system is approved by 8 LRQA.