Electrically Operated Pressure Relief Cartridge, Size 1 Seated Design, Direct Acting Series WUVA 1LO...

Size: px
Start display at page:

Download "Electrically Operated Pressure Relief Cartridge, Size 1 Seated Design, Direct Acting Series WUVA 1LO..."

Transcription

1 Electrically Operated Pressure Relief Cartridge, Size Seated Design, Direct Acting Series WUVA LO....5 l/min, 40 bar Wet armature solenoid with high pressure core tube and slip on coil Coils can be changed without opening the hydraulic envelope Coils with DIN, Deutsch, Kostal or Junior Timer plug connections can be supplied all external parts are chromited and are Cr VI free Suitable for pilot functions Can be fitted in a line mounting body. Description Series WUVA LO... cartridges are screw in, electrically operated pressure relief valves, nominal size mm. They are direct acting seat valves. The mounting thread is the 3/4" 6 UNF pattern. Their preferred application is as pilot control valves. Any pressure at port on the secondary pressure side is additive to the valve setting, therefore port should preferably be routed directly to tank. All external parts are chromited (Cr VI free) and the valves are thus suitable for use in the harshest operating environments. The cartridges can be fitted in the AL cavity and also in some 3/4" 6 UNF cavities from other valve manufacturers. For customers who manufacture their own manifold blocks, we offer form tool sets for sale or hire. The GALA body with G 3/8" port threads is available for pipe mounting applications.. Symbol 3. Main characteristics Designation pressure relief cartridge Design seat valve design, direct acting Mounting method screw in cartridge, 3/4" 6 UNF Size nominal size mm, cavity type AL Weight kg 0.45 Mounting attitude unrestricted Flow direction, see symbol Operating pressure range in port in port bar Pressure setting range bar pressure range 4 = pressure range 35 =... 3 pressure range 5 =... pressure range 6 = pressure range 0 =... pressure range 04 = Hydraulic fluid HL and HLP hydraulic oils to DIN 5 54; for other fluids, please consult BUCHER Fluid temperature range C Ambient temperature C Viscosity range mm /s (cst) recommended 5... Flow rate Q max. l/min.5, see performance graphs Replaces: D 6.0 /5 Classification: Reference: 400 P 870 E 0/09.07

2 Minimum fluid cleanliness level 0/8/5 to ISO 4406 : 999 Nominal voltages VAC VDC 5, 30, (...60 Hz), 4 Nominal voltage tolerance % ± 0 Nominal power consumption W VAC = 5, VDC = 7 Relative duty cycle % Protection class IP 65 / IP 67, see Ordering code" (when connector plugs are properly fitted) Electrical connection 3 pin square plug to DIN EN (standard) for other connectors, see Ordering code" 4. Performance graphs measured with oil viscosity 33 mm /s (cst) Type WUVA LO 4... Type WUVA LO ,3 0,6 0,9,,5 Type WUVA LO 5... Type WUVA LO Type WUVA LO 0... Type WUVA LO P 870 E 0/09.07 /5

3 5. Setting the pressures (pressure p must be set first, followed by pressure p) Setting the higher pressure p with pump running and solenoid energised:. Slacken cap nut item and remove it.. Slacken lock nut item () approx. / turn. 3. With pump running and solenoid energised, use the two flats (7 A/F) to turn adjusting screw item 9 until the required pressure is set in. 4. Hold the adjusting screw item 9 using the 7 A/F flats while tightening the lock nut item (). 5. Refit cap nut item and tighten it. Setting the lower pressure p (second relief setting, or vented pressure) with pump running and solenoid de energised:. Slacken cap nut item and remove it.. With pump running and solenoid de energised, use the adjusting screw item 0 (.5 A/F hex. socket) to set the pressure p in. (p min.:... 0 bar, dependent on flow rate). 3. Refit cap nut item and tighten it. When setting pressure p, do not over tighten the adjusting screw item 9 as this can destroy the stop ring that limits the maximum pressure setting. Stop turning as soon as a definite end stop can be felt. 7 A/F 9 Adjustment for the higher pressure p Hex. socket.5 A/F 0 Adjustment for the lower pressure p, and for emergency pressure setting if the power supply or coil fail E p (bar) Example showing the adjustable pressures p and p ( p p ) Time (t) D WUVPA... ( ON / OFF ) The relief pressure p is set as the higher working pressure (D) (solenoid energised) p is set as a low vented pressure (E) (solenoid is de energised) D = pressure p; as set with item 9, solenoid ON E = pressure p; can be set with item 0 to a maximum equal to D, solenoid OFF 400 P 870 E 0/ /5

4 6. Dimensions 0 PG , /4 6 UNF ø 3 A/F hex., tightening torque Ma = Nm, for fitting the cartridge. Line mounting body type GALA ø 5.8 Cavity type AL 7. Schematic section 3 PG 9 Seal kit no. DS 37, comprising: It. Qty. Description Size O ring no x.78 N90 O ring no x.78 N90 3 O ring 6.00 x.00 Viton 4 Backup ring 0.70 x.45 x.0 FI P 870 E 0/ /5

5 8. Installation and servicing All work must be carried out with care and by qualified personnel only. When fitting the cartridge, ensure that the seals are oiled or greased and use the specified tightening torque. When changing seals, oil or grease the new seals thoroughly before fitting them. 9. Ordering code Ex. WU V A L O 35 _ 4 VDC _ Electrically operated pressure relief valve Two stage A... Q = standard model see relevant data sheets Z... R = special features please consult BUCHER = pressure function (pressure relief) L = cavity type AL O = normally open 4 = pressure range bar 35 = pressure range... 3 bar 5 = pressure range... bar 6 = pressure range bar 0 = pressure range... bar 04 = pressure range bar = nominal size mm (blank) = Nitrile seals (standard) V = Viton seals (special seals consult Bucher)... 9 = design number (omit when ordering new units)... = voltage and current plainly specified (blank) = with mating plug to DIN EN (standard, IP 65) M = without mating DIN EN plug C = Kostal plug connection (IP 65) JT = Junior Timer radial plug connection (with quenching diode, IP65) IT = Junior Timer axial plug connection (with quenching diode, IP65) mating plug not supplied D = Deutsch plug connection DT04 P (IP 67) (optional connector styles) DT = Deutsch plug connection DT04 P (with quenching diode, IP 67) F = flying leads (0 mm) 0. Related data sheets Old no. New no. i P 0400 E The form tool hire programme i P 0407 E Cavity type AL W P 00 E Coils for screw in cartridge valves G P 700 E Line mounting body, type GALA (G 3/8") BUCHER HYDRAULICS Germany Phone Fax info.de@bucherhydraulics.com France Phone Fax info.fr@bucherhydraulics.com Netherlands Phone Fax info.nl@bucherhydraulics.com UK Phone Fax info.uk@bucherhydraulics.com USA Phone Fax info.wi@bucherhydraulics.com Switzerland Italy Austria China Product Center (Elevator) Phone Fax info.ch@bucherhydraulics.com Phone Fax info.it@bucherhydraulics.com Phone Fax Phone Fax info.bj@bucherhydraulics.com Phone Fax info.nh@bucherhydraulics.com We reserve the right of modification without notice. 400 P 870 E 0/ /5

Electrically Operated Pressure Relief Cartridge, Size 16 Seated Pilot Stage, Spool Type Main Stage Series WUVPA 1...

Electrically Operated Pressure Relief Cartridge, Size 16 Seated Pilot Stage, Spool Type Main Stage Series WUVPA 1... Electrically Operated Pressure Relief Cartridge, Size 16 Seated Pilot Stage, Spool Type Main Stage Series WUVPA 1... 3 l/min, 420 bar Two pressure valve, ON / OFF or HI / LO With internal pilot drain to

More information

Electrically Operated Pressure Reducing Cartridge, Size 16 Seated Pilot Stage, Spool Type Main Stage Series WDRVPA 5...

Electrically Operated Pressure Reducing Cartridge, Size 16 Seated Pilot Stage, Spool Type Main Stage Series WDRVPA 5... Electrically Operated Pressure Reducing Cartridge, Size 16 Seated Pilot Stage, Spool Type Main Stage Series WDRVPA... 2 l/min, 3 bar Two pressure valve, HI / LO External pilot drain to port 3 Surface protection:

More information

Proportional Pressure Reducing Valve, Size 16 Series DRPSB 5B...

Proportional Pressure Reducing Valve, Size 16 Series DRPSB 5B... Proportional Pressure Reducing Valve, Size 16 Series DRPSB B... l/min, bar External pilot drain to port 3 Surface protection: Cartridge is chromited, Cr VI free Very stable operation Coil can be changed

More information

Proportional Flow-Control Cartridges, Size 5

Proportional Flow-Control Cartridges, Size 5 Proportional Flow-Control Cartridges, Size Q max = l/min, p max = bar, Q N = l/min at p bar Leak free, load compensated, two stage Description Series MVRPLSA two-stage proportional flow-control cartridges

More information

2/2 Solenoid Cartridge Valve, Size 10

2/2 Solenoid Cartridge Valve, Size 10 2/2 Solenoid Cartridge Valve, Size 1 Q max = 8 l/min, p max = 3 bar Seat-valve shut-off, two-stage, monitored operating position 1 Description With integral electronic monitoring of operating position

More information

2/2 Cartridge Seat Valve, Size 5

2/2 Cartridge Seat Valve, Size 5 / Cartridge Seat Valve, Size Q max = l/min, p max = bar Digital valve, bidirectional seat-valve shut-off, direct acting Series WSGD / WSOD For use in digital hydraulics With bidirectional seat-valve shut-off

More information

3/2 Solenoid Cartridge Valve, Size 6

3/2 Solenoid Cartridge Valve, Size 6 / Solenoid Cartridge Valve, Size 6 Q max = 4 l/min ( gpm), p max = 5 bar (45 psi) Bidirectional seat-valve shut-off, direct acting Series W.B, WF.B Guided valve spool and poppet Two spool variants are

More information

3/2 Solenoid Cartridge Valve, Size 6

3/2 Solenoid Cartridge Valve, Size 6 / Solenoid Cartridge Valve, Size 6 Q max = l/min, p max = 5 bar Bidirectional seat-valve shut-off, direct acting Guided valve spool and poppet Two spool variants are available Available in two mounting

More information

2/2 Logic Cartridge Valve, Size 10

2/2 Logic Cartridge Valve, Size 10 2/2 Logic Cartridge Valve, Size 10 Q max = 10 l/min, p max = 420 bar ctive Control, Seated Design ctive control rea ratio 2 : 1 High flow rates with low p Seat-valve shut-off from and No pilot oil consumption

More information

2/2 Solenoid Cartridge Valve, Size 6

2/2 Solenoid Cartridge Valve, Size 6 / Solenoid Cartridge Valve, Size 6 Q max = l/min (.3 gpm), p max = 3 bar (4 psi) Bidirectional leak-proof shutoff, direct acting, with EX-safty solenoid coil Description Valve: Bidirectional leak-proof

More information

Monobloc and Sectional Directional Control Valves

Monobloc and Sectional Directional Control Valves Monobloc and Sectional Directional Control Valves motion and progress 1/220 6 Monobloc directional control valves Contents 6.1 General specifications 66 6.2 Dimensional data 67 6.3 Performances curves

More information

Proportional Valves MODEL DESCRIPTION FLOW CAVITY 4/3 PROPORTIONAL DIRECTIONAL VALVE 8 GPM C1040 PDFC-4M PDFC-4L

Proportional Valves MODEL DESCRIPTION FLOW CAVITY 4/3 PROPORTIONAL DIRECTIONAL VALVE 8 GPM C1040 PDFC-4M PDFC-4L Proportional Valves MODEL DESCRIPTION FLOW CAVITY 4 b a PDFC-4M 4/3 PROPORTIONAL DIRECTIONAL VALVE 8 GPM C040 4 3 b a PDFC-4L 3 3 EPRR-0 PROPORTIONAL PRESS. REDUCING/RELIEVING GPM C030 EPRT-08 PROPORTIONAL

More information

2/2 Logic Cartridge Valve, Size 10

2/2 Logic Cartridge Valve, Size 10 2/2 Logic Cartridge Valve, Size 10 Q max = 10 l/min, p max = 420 bar ctive Control, Seated Design, Soft Switching 1 Description ctive control Soft switching, or soft switching + snap action Seated valve

More information

Monobloc and Sectional Directional Control Valves

Monobloc and Sectional Directional Control Valves Monobloc and Sectional Directional Control Valves 200 P 991210 E 03 / 10.04 1/220 2 Monobloc directional control valves HDM140 Contents 2.1 General specifications 9 2.2 Dimensional data 10 2.3 Performances

More information

High Pressure Internal Gear Pumps Series QX

High Pressure Internal Gear Pumps Series QX High Pressure Internal Gear Pumps Series QX motion and progress 1 / 32 Classification: 410.10..00 Reference: -P -000021 -E -06 / 05.05 Contents 1 General 1.1 Product description 3 1.2 Advantages 3 2 Technical

More information

Flow Control Valve. 1 Description. 2 Symbols. Series SRCA General. 1.2 Application examples way flow control way flow control

Flow Control Valve. 1 Description. 2 Symbols. Series SRCA General. 1.2 Application examples way flow control way flow control Flow Control Valve Series SRC.. plug-in coil for easy coil change flow rates are unaffected by changes in temperature or load compact design reduced p ZnNi coating (>70h DIN EN ISO 97 NSS) Description.

More information

Flow Control Valve. 1 Description. 2 Symbols. Series SRCA General. 1.2 Application examples way flow control way flow control

Flow Control Valve. 1 Description. 2 Symbols. Series SRCA General. 1.2 Application examples way flow control way flow control Flow Control Valve Series SRC.. plug-in coil for easy coil change flow rates are unaffected by changes in temperature or load. compact reduced p ZnNi coating (>70h DIN EN ISO 97 NSS) Description. General

More information

Check Valves, Size Spherical Poppet-type, Screw-in Design Series RKVE l/min, 350 bar (500 bar)

Check Valves, Size Spherical Poppet-type, Screw-in Design Series RKVE l/min, 350 bar (500 bar) Check Valves, Size 04... 40 Spherical Poppet-type, Screw-in Design Series RKVE... 360 l/min, 350 bar (500 bar) 1 General 1.1 Product description Series RKVE units are screw-in check valves with mounting

More information

Monobloc and Sectional Directional Control Valves

Monobloc and Sectional Directional Control Valves Monobloc and Sectional Directional Control Valves motion and progress 1/220 10 Sectional directional control valves HDS20 Contents 10.1 General specifications 177 10.2 Dimensional data 178 10.3 erformances

More information

Monobloc and Sectional Directional Control Valves

Monobloc and Sectional Directional Control Valves Monobloc and Sectional Directional Control Valves 200--991210-N-03/09.2015 03 / 10.04 1/220 11 Sectional directional control valves HDS30 Contents 11.1 General specifications 197 11.2 Dimensional data

More information

unrestricted; preferably with coil at bottom (auto. air bleed) 12 or 24 Volt DC from an electronic controller Deutsch plug - IP67

unrestricted; preferably with coil at bottom (auto. air bleed) 12 or 24 Volt DC from an electronic controller Deutsch plug - IP67 3 Technical data General characteristics Design Flow direction Seals De-energized position Mounting attitude Description, value, unit line mounting P A controlled P R surplus flow discharge (models shown

More information

Check Valve, Size 04 16

Check Valve, Size 04 16 , Size 04 6 Spherical poppet-type, screw-in design Series RKVE -VD 0 l/min, 50 bar for the same pressure differential, Q max. is around 50% higher than with standard RKVE valves no soft seal, therefore

More information

SD3E-B2. Functional Description. 2/2 Way Solenoid Operated Directional Control Valves Poppet Type HA /2012. Replaces HA /2010

SD3E-B2. Functional Description. 2/2 Way Solenoid Operated Directional Control Valves Poppet Type HA /2012. Replaces HA /2010 / Way Solenoid Operated Directional Control Valves Poppet Type SD3E-B 7/8-4 UNF p max 40 bar (609 PSI) Q max 75 L/min (9.8 GPM) H 4063 7/0 Replaces H 4063 0/00 / way cartridge valves solenoid operated

More information

Chapter 2: Directional Control Valves

Chapter 2: Directional Control Valves Contents Chapter : Directional Control Valves Series Description Direct operated Pilot operated Page DIN / ISO 06 10 16 5 3 10 16 5 3 Seat valves, electrically operated D1SE - Spool valves, electrically

More information

Seated valves 500 bar

Seated valves 500 bar Seated valves 500 bar Type WVM-6I Features Solenoid actuated and direct operated Leakage free in every direction (double tight) High operational safety and reliable switching High duty cycles and long

More information

SD2E-A3. Functional Description. 3/2 Way Solenoid Operated Directional Control Valves Spool Type HA /2013. Replaces HA /2012

SD2E-A3. Functional Description. 3/2 Way Solenoid Operated Directional Control Valves Spool Type HA /2013. Replaces HA /2012 3/2 Way Solenoid Operated Directional Control Valves Spool Type SD2E-A3 3/4-6 UNF p max 350 bar (5076 PSI) Q max 30 L/min (7.9 GPM) HA 404 /203 Replaces HA 404 07/202 Hardened and precision working parts

More information

Proportional Pressure Reducing Valve PDM08130

Proportional Pressure Reducing Valve PDM08130 Proportional Pressure Reducing Valve PDM08130 up to 80 bar up to 10 l/min Cartridge valves Control electronics Connection housings 486 1. DESCRIPTION 1.1. GENERAL According to DIN-ISO 1219, HYDAC proportional

More information

6/2 ways/positions flow diverters L (VS151-VS152-VS155)

6/2 ways/positions flow diverters L (VS151-VS152-VS155) 6/2 ways/positions flow diverters L721... (VS151-VS152-VS155) RE 1832-5 Edition: 2.216 Replaces: 5.214 Size 6 Series 1 Maximum operating pressure 31 bar (45 psi) Maximum flow 6 l/min (15.85 gpm) Ports

More information

Pressure Relief Valve

Pressure Relief Valve ressure Relief Valve For mounting on hydraulic pumps and motors Series ASDF and AGDF S short response times S trouble-free operation S with improved pressure-adjustment resolution S high levels of functionality

More information

2/2-way poppet valves with solenoid operation Type KSDER1

2/2-way poppet valves with solenoid operation Type KSDER1 RE 8 36-0/0.0 Replaces: 07.0 /-way poppet valves with solenoid operation Type KSDER Build size T-3A cavity Maximum operating pressure 350 bar Maximum flow 0 L/min H/A/D 680/0 Type KSDER.A/HC... Overview

More information

Stand alone 4/3, 4/2 solenoid operated directional valve

Stand alone 4/3, 4/2 solenoid operated directional valve Stand alone 4/3, 4/2 solenoid operated directional valve (LF ) FAN DRIVE (LF ) RE 1835-4 Edition: 2.216 Replaces: 7.12 7.212 LF1 Size 6 LF2 Size 1 Series LF1 Maximum operating pressure 31 (45 ) LF2 Maximum

More information

Proportional pressure relief valve, directly operated, rising characteristic curve

Proportional pressure relief valve, directly operated, rising characteristic curve Proportional pressure relief valve, directly operated, rising characteristic curve RE 1139-0/09.07 Replaces: 0.05 1/1 Type KBPS.A (High-Performance) Component series A Maximum operating pressure 0 bar

More information

3/2 ways/positions flow diverters L (VS91-VS92-VS95)

3/2 ways/positions flow diverters L (VS91-VS92-VS95) 3/2 ways/positions flow diverters L706... (VS91-VS92-VS95) RE 18302-03 Edition: 04.2016 Replaces: 02.2016 Size 12 Series 00 Maximum operating pressure 310 bar (4500 psi) Maximum flow 140 l/min (36.98 gpm)

More information

SR1A-A2. Functional Description HA /2012. Directly Operated Pressure Relief Valves. Replaces HA /2010. Screw-in cartridge design

SR1A-A2. Functional Description HA /2012. Directly Operated Pressure Relief Valves. Replaces HA /2010. Screw-in cartridge design Directly Operated Pressure Relief Valves SRA-A2 HA 5063 7/202 3/4-6 UNF p max 350 bar (5080 PSI) Q max 30 L/min (7.9 GPM) Replaces HA 5063 8/200 Screw-in cartridge design 4 pressure ranges Pressure setting

More information

Pilot Operated Pressure Relief Valve Series R5V (Denison)

Pilot Operated Pressure Relief Valve Series R5V (Denison) Characteristics Pilot operated pressure relief valves series R5V have a similar design to the subplate mounted R4V series. The SAE flanges allow to mount the valves directly on the outlet flanges of pumps

More information

Directional Control Valve Series D3W Soft Shift

Directional Control Valve Series D3W Soft Shift Characteristics The D3W is a 3-chamber, electrically controlled 4/3 or 4/ way directional control valve. It is activated directly by solenoids with screwed in wet pin armature. The soft shifting of this

More information

Flow Control Valve. 1 Descriptions. 2 Symbols. Series SRCB Generals. 1.2 Application examples way flow control way flow control

Flow Control Valve. 1 Descriptions. 2 Symbols. Series SRCB Generals. 1.2 Application examples way flow control way flow control Flow Control Valve Series SRC.. plug-in solenoid for easy coil change flow rates are unaffected by temperature change or when the higher load pressure alternates between the outlet ports energy - optimised

More information

6/2 ways/positions flow diverters L (VS120-VS125-VS129)

6/2 ways/positions flow diverters L (VS120-VS125-VS129) 6/2 ways/positions flow diverters L710... VS120-VS125-VS129) RE 18302-04 Edition: 05.2014 Replaces: 07.12 Size 4 Series 00 Maximum operating pressure 310 bar 4500 psi) Maximum flow 25 l/min 6.6 gpm) Ports

More information

3/2 directional spool valve, direct operated with solenoid actuation

3/2 directional spool valve, direct operated with solenoid actuation / directional spool valve, direct operated with solenoid actuation RE 86-4/6. Replaces:.9 / Type KKDE (high-performance) Size Component series A Maximum operating pressure 5 bar Maximum flow 6 l/min H68

More information

GPM PSI LPM BAR MODEL CAVITY PAGE IF-S3A special IF-S3D special IG-S4A special 198

GPM PSI LPM BAR MODEL CAVITY PAGE IF-S3A special IF-S3D special IG-S4A special 198 Transmission & Brake Spool Valves Screw-in style GPM PSI LPM BAR MODEL CAVITY PAGE 2 1000 8 70 TC-S3A 5/8-18 186 6 1000 23 70 TF-S3A 7/8-14 188 6 1000 23 70 TF-S3D 7/8-14 190 5 1000 20 70 TG-S4A 7/8-14

More information

SD2E-A4. Functional Description. 4/2 Way Solenoid Operated Directional Control Valves Spool Type HA /2014. Replaces HA /2013

SD2E-A4. Functional Description. 4/2 Way Solenoid Operated Directional Control Valves Spool Type HA /2014. Replaces HA /2013 / Way Solenoid Operated Directional Control Valves Spool Type SDE- /-6 UNF p max 50 bar (5076 PSI) Q max 0 L/min (7.9 GPM) 07/0 Replaces 0/0 Hardened precision working parts High flow capacity High transmitted

More information

Cartridge Valves Technical Information Directional Valves DCV 03

Cartridge Valves Technical Information Directional Valves DCV 03 OVERVIEW DCV 03 directional control valves consist of: housing (1), control spool (5), with two centering springs (4), and cylindrical operating solenoids (2, 3). The three-position directional valves

More information

Intelligent Lift Control Valve with Electronic Card

Intelligent Lift Control Valve with Electronic Card Intelligent Lift Control Valve with Electronic Card Q max = 500 l/min, p max = 80 bar Leak-free, two-stage, electronically controlled, without frequency control i50 and i500 Information lift-control valve

More information

6 to14/2 ways/positions bankable flow diverters flangeable

6 to14/2 ways/positions bankable flow diverters flangeable 6 to14/2 ways/positions bankable flow diverters flangeable RE 18302-10/07.12 Replaces: 12.09 1/8 L745... (VS281F-VS285F-VS286F-VS287F-VS289F) Size 10 Series 00 Maximum operating pressure 310 bar [4500

More information

3-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

3-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow 3-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow A-VRFC3C-VEI-VS-LS 0M.43.21.80 - Y - Z RE 18309-63 Edition: 03.2018 Replaces: 03.2016 Technical

More information

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow 3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow A-VRFC3C-VEI-VS 0M.43.20.80 - Y - Z RE 18309-3 Edition: 03.2018 Replaces: 03.2016 Technical data Description

More information

Proportional pressure relief valve, pilot-operated, with anti-cavitation function, decreasing characteristic curve Type KBVS.2DB

Proportional pressure relief valve, pilot-operated, with anti-cavitation function, decreasing characteristic curve Type KBVS.2DB Proportional pressure relief valve, pilot-operated, with anti-cavitation function, decreasing characteristic curve Type KBVS.2DB RE 18377 Edition: 11.2017 Size 2 Series B Maximum working pressure 420 bar

More information

Proportional Directional Valve System

Proportional Directional Valve System roportional Directional Valve System in Sectional Design Reference: 31--9589-ENG-2 Issue: 8.215 1/2 Contents age 1 General... 3 1.1 Description... 3 1.2 pplication examples... 3 2 Technical data... 3 3

More information

SD2E-A4. Functional Description. 4/2 Way Solenoid Operated Directional Control Valves Spool Type HA /2012. Replaces HA /2010

SD2E-A4. Functional Description. 4/2 Way Solenoid Operated Directional Control Valves Spool Type HA /2012. Replaces HA /2010 4/2 Way Solenoid Operated Directional Control Valves Spool Type SD2E-4 /4-16 UNF p max 50 bar (5076 PSI) Q max 0 L/min (7.9 GPM) 7/2012 Replaces 10/2010 4/2 way cartridge valves solenoid operated spool

More information

Chapter 6: Check Valves

Chapter 6: Check Valves Contents Chapter : Check Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/8 1/4 3/8 1/2 3/4 1 0 10 1 25 32 Subplate Screw-in Slip-in Shuttle valves SSR -2 Check valves, direct operated

More information

Stand alone 4/3, 4/2 direct acting directional valve LF2_1 (LC2F-DZ)

Stand alone 4/3, 4/2 direct acting directional valve LF2_1 (LC2F-DZ) Stand alone 4/3, 4/2 direct acting directional valve LF2_1 (LC2F-DZ) RE 18305-03 Edition: 02.2016 Replaces: 07.12 07.2012 Size 10 Series 00 Maximum operating pressure 250 bar (3600 psi) Maximum flow 90

More information

Directional Control Valve Series 4D01 (DENISON)

Directional Control Valve Series 4D01 (DENISON) Characteristics The Denison series 4D01 is a solenoid operated directional control valve size NG06 in -chamber design. It is direct operated by wet pin solenoids. The 4D01 is available with a Soft Shift

More information

Chapter 6: Check Valves

Chapter 6: Check Valves Contents Chapter : Check Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/8 1/4 3/8 1/2 3/4 1 0 10 1 25 32 Subplate Screw-in Slip-in SSR RK / RB CS SPZBE SPV / SPZ C4V CPS C4V D4S

More information

6 to14/2 ways/positions bankable flow diverters flangeable

6 to14/2 ways/positions bankable flow diverters flangeable Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service 6 to14/2 ways/positions bankable flow diverters flangeable RE 18302-09/12.09 1/10 L732... (VS241F-VS245F-VS246F-VS247F)

More information

2/2 directional seat valve, direct operated with solenoid actuation

2/2 directional seat valve, direct operated with solenoid actuation / directional seat valve, direct operated with solenoid actuation RE 836-/0. Replaces: 06.08 /0 Type KSDE (High Performance) Component size 8 Component series B Maximum operating pressure 500 bar Maximum

More information

Proportional Valves. Proportional solenoid valves for pressure and flow control B-1.A. An Eaton Brand

Proportional Valves. Proportional solenoid valves for pressure and flow control B-1.A. An Eaton Brand Proportional Valves Proportional solenoid valves for pressure and flow control An Eaton rand -.A Proportional Valves Valve Locator/Section Contents Note: Proportional valve solenoid coils and electronic

More information

Prop. directional seated valve type EM 21 DE and EM 21 DSE intended as pilot valve

Prop. directional seated valve type EM 21 DE and EM 21 DSE intended as pilot valve Prop. directional seated valve type EM 21 DE and EM 21 DSE intended as pilot valve Operation pressure p max = 420 bar Flow Q max = 3.5 lpm See also: Directional seated valves type EM and EMP D 7490/1 Prop.

More information

Functional Description

Functional Description 4/2 Way Solenoid Operated Directional Control Valves Spool SD2E-A4 Type 3/4-16 UNF p max 350 bar (5076 PSI) Q max 30 L/min (7.9 GPM) 01/2005 4/2 Way cartridge valves solenoid operated spool directed Manual

More information

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1.

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1. Solenoid Valves Poppet and Spool type solenoid actuated valves for applications up to 5 bar (5 psi) and 7 L/min (6 USgpm) n Eaton Brand ETON Screw-In Cartridge Valves E-VLSC-MC-E November 9 -. Solenoid

More information

Directional Control Valve Series D1VW

Directional Control Valve Series D1VW Characteristics The NG6 directional control valve series D1VW provides high functional limits up to 8 l/min in combination with a very low, energy-saving pressure drop. A wide variety of spool options

More information

6 to 12/2 ways/positions bankable flow diverters flangeable

6 to 12/2 ways/positions bankable flow diverters flangeable 6 to 12/2 ways/positions bankable flow diverters flangeable RE 18302-08/07.12 Replaces: 12.09 1/8 L711... (VS120F-VS125F) Size 4 Series 00 Maximum operating pressure 310 bar [4500 psi] Maximum flow 20

More information

6 to14/2 ways/positions bankable flow diverters flangeable

6 to14/2 ways/positions bankable flow diverters flangeable Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service 6 to14/2 ways/positions bankable flow diverters flangeable RE 18302-10/12.09 1/8 L745... (VS281F-VS285F-VS286F-VS287F-VS289F)

More information

4/3, 4/2 and 3/2 Directional Valve with Wet-pin AC or DC Solenoid

4/3, 4/2 and 3/2 Directional Valve with Wet-pin AC or DC Solenoid 01/08 /3, /2 and 3/2 Directional Valve with Wet-pin AC or DC Solenoid 2.1 Type WE 10...L5X Size (NG) 10 Up to 350 bar Up to 150 L/min Contents Function and configurations -03 Specifications 0 Symbols 05

More information

6/2 ways/positions flow diverters

6/2 ways/positions flow diverters 6/2 ways/positions flow diverters RE 18302-07/07.12 Replaces: 12.09 1/8 L753... (VS311-VS312-VS315) Size 10 Series 00 Maximum operating pressure 310 bar [4500 psi] Maximum flow 140 l/min [36,98 gpm] Ports

More information

6/2 ways/positions flow diverters

6/2 ways/positions flow diverters Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service 6/2 ways/positions flow diverters RE 1832-5/12.9 1/8 L721... (VS151-VS152-VS155) Size 6 Series 1 Maximum

More information

COILS AND CONNECTORS. Atlantic Fluid Tech SECTION 21. Rev. 10/ Connector Page class

COILS AND CONNECTORS. Atlantic Fluid Tech SECTION 21. Rev. 10/ Connector Page class SECTION 21 COILS AND CONNECTORS Type Heat insulation Connector Page class Coil M7 HS M7 - For solenoid operated cartridge valve H - 1 C EN 175301-3 - DIN 450 - ISO 4400 21.00.010 Coil M7 HS M7 - For solenoid

More information

Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VW

Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VW Characteristics The pilot operated valves are available in 4 sizes: D31DW NG10 (standard) D31NW NG10 (high flow) D41VW NG16 D81VW NG5 (for port diameter up to 6 mm) D91VW NG5 (for port diameter up to 3

More information

3/2 ways/positions flow diverters

3/2 ways/positions flow diverters Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service 3/2 ways/positions flow diverters RE 18302-02/12.09 1/8 L705... (VS81-VS82-VS84-VS85) Size 6 Series 00

More information

Differential Lock Valve

Differential Lock Valve Differential Lock Valve Series M..DVD (for 3 motors) robust and reliable energy-optimised over the whole flow range simple control compact design offers space-saving installation reliable, uniform motion

More information

Proportional Valves. Proportional solenoid valves for pressure and flow control

Proportional Valves. Proportional solenoid valves for pressure and flow control Proportional Valves Proportional solenoid valves for pressure and flow control EATON Vickers Screw-In Cartridge Valves V-VLOV-MC-E4 September, 7 - Electro- Proportional Valves Section Contents Typical

More information

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow 3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow A-VRFC3C-VEI-VS 0M.43.20.80 - Y - Z RE 18309-3 Edition: 03.2016 Replaces: 06.2010 Technical data Description

More information

4/3-4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections

4/3-4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections 4/3-4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections RE 183-52/7.12 Replaces: 1.9 1/8 8_8 (EDZ) Size 4 Series Maximum operating pressure 31 bar

More information

Examples 3/2-way valve A T NO: Symbol

Examples 3/2-way valve A T NO: Symbol 1/1 Hauhinco-3_2-way valve_b1_dn3-25_pn320_pn500_x,y-intern water s 01/2016 3/2-way valve B1 X,Y - DN3 DN25 PN320, PN500 Features: Hydraulically actuated directional seat valve controlling liquid media.

More information

4/3 and 4/2 Proportional directional valve elements L8581 with flow (EDC-P1) sharing control (LUDV concept) PATENT PENDING

4/3 and 4/2 Proportional directional valve elements L8581 with flow (EDC-P1) sharing control (LUDV concept) PATENT PENDING 4/3 and 4/2 Proportional directional valve elements L881 with flow (EDC-P1) sharing control (LUDV concept) PATENT PENDING L881 (EDC-P1) RE 1831-1 Edition: 6.218 Replaces: 7.12.217 Size 6 Series Maximum

More information

Directional Controls

Directional Controls Vickers Directional Controls Wet Armature Solenoid Operated Directional Control Valves Model DGV-, Series Typical Construction of a Spring-Centered DC Valve with Variable Speed Pilot Control passage Speed

More information

Pilot-Operated Directional Control Valves Series D3 - D11

Pilot-Operated Directional Control Valves Series D3 - D11 Catalogue HY11-500/UK Characteristics The D31, D41, D81, D91 and D111 are electrical controlled 4/3 or 4/ way directional control valves. The valves are pilot-operated by an NG6 valve. Pressure and flow

More information

Solenoid valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm)

Solenoid valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) Hydraulic Screw-in Cartridge Valves (SiCV) Solenoid valves Poppet and Spool type solenoid actuated valves for applications up to 5 bar (5 psi) and 7 L/min (6 USgpm) Solenoid valves SOLENOID VLVES...- SV5-8-C/CM

More information

4/3 4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections

4/3 4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections RA 183-52/1.11 1/1 4/3 4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections B8_8 (EDBZ) Summary Description Page General specifications 1 Ordering

More information

4/3-4/2 Directional valve elements LF1_1 (LC1F-Z)

4/3-4/2 Directional valve elements LF1_1 (LC1F-Z) 4/3-4/2 Directional valve elements LF1_1 LC1F-Z) RE 18305-01 Edition: 02.2016 Replaces: 07.12 07.2012 Size 6 Series 00 Maximum operating pressure 310 bar 4500 psi) Maximum flow 35 l/min 9.25 gpm) Ports

More information

Directional Seat Valve Series D4S (Denison)

Directional Seat Valve Series D4S (Denison) Characteristics Seat valves series D4S are designed for directional control functions. A large variety of poppets, springs and covers - including shuttle valves, stroke limiters, solenoid valves (VV01)

More information

RPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007

RPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007 Directional Control Valves Solenoid Operated RPE3-04 Size 04 (D 02) 320 bar (4600 PSI) 30 L/min (8.0 GPM) 10/2010 Replaces 12/2007 4/3-, 4/2- way directional control valves with solenoid control Solenoids

More information

Proportional pressure reducing valve, direct operated, increasing characteristic curve Type MHDRE 06 SK (high-performance)

Proportional pressure reducing valve, direct operated, increasing characteristic curve Type MHDRE 06 SK (high-performance) Proportional pressure reducing valve, direct operated, increasing characteristic curve Type MHDRE 6 SK (high-performance) RE 64655 Edition: 7.218 Replaces: 11.216 Size 6 Series 3X Maximum control pressure

More information

Pilot control unit with end position lock for the remote control of directional valves

Pilot control unit with end position lock for the remote control of directional valves Pilot control unit with end position lock for the remote control of directional valves RE 64 553/02.07 1/12 Replaces : 05.05 Type 4THF6 or 5THF6 Series 2X Contents Functional description, section, symbol

More information

Flow sharing control block in mono block / sandwich plate design M6-15

Flow sharing control block in mono block / sandwich plate design M6-15 Flow sharing control block in mono block / sandwich plate design M6-15 RE 64321 Edition: 01.2015 Replaces: 05.2012 Size 15 Series 3X Maximum operating pressure on pump side 350 bar on consumer side 420

More information

Proportional pressure reducing valve, direct operated, increasing characteristic curve Type MHDRE 06 FK (high-performance)

Proportional pressure reducing valve, direct operated, increasing characteristic curve Type MHDRE 06 FK (high-performance) Proportional pressure reducing valve, direct operated, increasing characteristic curve Type MHDRE 06 FK (high-performance) RE 64656 Edition: 07.18 Replaces: 11.16 Size 6 Series 3X Maximum control pressure

More information

4/3 and 4/2 Proportional directional valve elements L8580 with flow (EDC-P) sharing control (LUDV concept) PATENT PENDING

4/3 and 4/2 Proportional directional valve elements L8580 with flow (EDC-P) sharing control (LUDV concept) PATENT PENDING / and / Proportional directional valve elements L88 with flow (EDC-P) sharing control (LUDV concept) PATENT PENDING L88 (EDC-P) RE 181-9 Edition:.16 Replaces: 7.1 7.1 Size 6 Series Maximum operating pressure

More information

DRV2-080 Adjustable, Direct-Acting Relief Valve

DRV2-080 Adjustable, Direct-Acting Relief Valve SOLENOID DRV2-080 Adjustable, Direct-Acting Relief Valve SERIES 8 CHECK MOTION FLOW USASI / ISO ➁ ➀ DESCRIPTION An adjustable, direct-acting poppet cartridge valve designed to limit pressure in hydraulic

More information

Directional Control Valve

Directional Control Valve Characteristics The NG6 directional control valve series D1VW provides high functional limits up to 8 l/min in combination with a very low, energy-saving pressure drop. wide variety of spool options allows

More information

Flow sharing control block in sandwich plate design M7-25

Flow sharing control block in sandwich plate design M7-25 Flow sharing control block in sandwich plate design M7-25 RE 64297 Edition: 07.2016 Replaces: 06.2012 Size 25 Series 3X Maximum working pressure on the pump side 380 bar on the consumer side 420 bar Maximum

More information

Flow sharing control block in mono block / sandwich plate design M6-22

Flow sharing control block in mono block / sandwich plate design M6-22 Flow sharing control block in mono block / sandwich plate design M6-22 RE 64322 Edition: 01.2015 Replaces: 05.2012 Size 22 Series 3X Maximum operating pressure on pump side 350 bar on consumer side 420

More information

Proportional Directional Control Cartridge Valves: PSV10-34 & PSV12-34

Proportional Directional Control Cartridge Valves: PSV10-34 & PSV12-34 Control Cartridge Valves: PSV10-34 & PSV12-34 SCHEMATIC PRESSURE* FLOW CAVITY COIL Page 2 PSV10-34-02 250 BAR 3600 PSI 22 LPM 6 GPM SDC10-4 M16-26W R16-20W Page 4 PSV12-34-02 260 BAR 3770 PSI 50 LPM 13

More information

Flow control valve range

Flow control valve range inspired hydraulics. Flow control valve range FPR102 Functional description Flow control valves of the FPR10 series are used for load independent and stepless adjusting of the operating speed of hydraulic

More information

6/2 ways/positions flow diverters

6/2 ways/positions flow diverters Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service 6/2 ways/positions flow diverters RE 18302-07/12.09 1/8 L753... (VS311-VS312-VS315) Size 10 Series 00

More information

FC2-1L Flow Control Valve, double

FC2-1L Flow Control Valve, double Table of content 1 General Description... 2 1.1 Applications... 2 1.2 Mounting Location (Recommendation)... 2 1.3 Function... 2 1.4 Characteristics... 2 2 Technical Data... 3 3 Ordering Information...

More information

Directional valve elements L808103P (ED4-PT1) of Tank unloaded excess flow. RE Edition: Replaces:

Directional valve elements L808103P (ED4-PT1) of Tank unloaded excess flow. RE Edition: Replaces: Directional valve elements L80810P with proportional (ED4-PT1) control of Tank unloaded excess flow L80810P (ED4-PT1) RE 1801-1 Edition: 09.2016 Replaces: 07.12 01.2016 Size 6 Series 00 Maximum operating

More information

4/3, 4/2 proportional directional valves solenoid operated (for open loop control)

4/3, 4/2 proportional directional valves solenoid operated (for open loop control) /, / proportional directional valves solenoid operated (for open loop control) RE -/7. Replaces: RE7/.7 / Type L (LCP) Size Series Maximum operating pressure bar [ psi] Nominal flow rated l/min [.7 gpm]

More information

4/3-4/2 Directional valve with solenoid actuation

4/3-4/2 Directional valve with solenoid actuation 4/3-4/2 Directional valve with solenoid actuation RE 18305-08/12.13 1/10 L5110 LC1-Z ) Size NG6 ISO 4401-03 CETOP RP121 H-03 CETOP 3) Series 00 Maximum operating pressure 350 bar [5076 psi] Maximum flow

More information

6 to 12/2 ways/positions bankable flow diverters flangeable

6 to 12/2 ways/positions bankable flow diverters flangeable Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service 6 to 12/2 ways/positions bankable flow diverters flangeable RE 18302-08/12.09 1/10 L711... (VS120F-VS125F)

More information

740 SERIES. hydraulics. Sun FLeX Series Low- & High-Power Coils LOW- & HIGH-POWER COILS: DC & AC VERSIONS WITH DIN & DEUTSCH CONNECTORS

740 SERIES. hydraulics. Sun FLeX Series Low- & High-Power Coils LOW- & HIGH-POWER COILS: DC & AC VERSIONS WITH DIN & DEUTSCH CONNECTORS hydraulics Sun FLeX Series Low- & High-Power Coils FLeX COMPATIBLE Works with Sun FLeX Series Solenoid Valves SIX COIL VOLTAGES 12, 14, 24, 28 Vdc 115/230 Vac CONNECTOR OPTIONS DIN & Deutsch OPTIMIZED

More information

Pressure Compensator Valves Series R5P (SAE Flange Mounted) General Description. Features

Pressure Compensator Valves Series R5P (SAE Flange Mounted) General Description. Features Technical Information General Description Series R5P direct operated, 3-way pressure compensators can be combined with any type of fixed or adjustable flow resistor (throttle) to provide a load compensated

More information