User Manual. H Frames. Original Instructions. Revision

Similar documents
User Manual. Doughty Clamps/Couplers. Original Instructions Revision 3 18/02/16 - CN

User Manual. Quick Trigger Clamps. Original Instructions Revision 2 06/10/15.

User Manual. T29870 Beam Clamp. Original Instructions. Rev /08//14.

User Manual. Studio Rail. Size Version

Information. Lighting Hoist. Version 10/07.

Operating Manual. Pantographs. Version 05/12.

Constant Running Hydraulic Pump Installation Guide. Document Number: Date: March 2006

Spare Parts List Ironman (Standard and LUL)

Installation and Operation Manual

BEAM CLAMP INSTRUCTION MANUAL

Dhatec Document No.: DHA415-APS-PH

type r remote drive for auxiliary

Hot Surface By Others IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION INSTRUCTIONS

SPH214 Small Panel Handler

INSTRUCTION MANUAL. Pacific Self-locking Beam Trolleys Pacific Adjustable Angle Clamps Pacific Top Girder Clamps

FASTON* High Temperature Tab Terminals

Trus-T-Lift 750 Limited Maintenance Manual. Copyright 2016

Oil Seal Catalogue. Ashley Power Ltd Ashley Road Parkstone Poole Dorset, BH14 0AQ. P1

K&F Rotation Clamp 450

Owner s Manual Gantry Cranes

User Guide Brake Test Tools Ø6 and Ø10

Hydraulic Pump Installation Guide

Safelift Overhead Runway Beams & Rolling Beam Cranes

PLASTI-GRIP* Terminals and Splices

AUTOLOK Heavy-Duty Rail Clamp

Fitting Instruction for EZI-GRIP Bike Rack

NK TRAILER. Operating Manual. Trailer. Hilomast LLC 402 Chairman Court Debary FL 32713

WHEELED WALKER OWNER S HANDBOOK

ov-lifting_bolts_divider - Updated Lifting Bolts

PVC Casing Cutter - Single Cutting Wheel (SCW) Sizes & , Operators Manual

OWNER S MANUAL PRODUCT CODE: 2006T

Kuhnke Technical Data. Contact Details

Step-Up100 and Step-Up150 Podium Instruction Manual

ov-lifting_bolts_divider - Updated Lifting Bolts

HYDRAULIC BENCH PRESS 50,000kg

Operating Manual TWN 0121/1. Lifting point, screw-type TWN 0122 TWN 0123 TWN 0127 TWN 1120 TWN 1830 TWN 1890

3.25 Ton Heavy Duty Floor Jack

SIBS Driveline Braking System Operator Manual MAN-029 SIBS OPERATOR MANUAL - DRIVELINE BRAKING SYSTEM (REV 2)

Uniclass L L2123 EPIC J3413. CI/SfB (52.5) If9. Surface drainage for heavy duty traffic applications ACO RoadDrain

Operator Instructions for Tension Links

1 TONNE FOLDING CRANE. 1 TONNE FOLDING CRANE MODEL No CFC100 PART No OPERATING & MAINTENANCE INSTRUCTIONS 1202

OPERATOR S MANUAL TWIN REGULATOR LUBRO CONTROL UNIT. Part Number Issue 3 Original Instructions (English)

NXLONG/HD TRAILER. Operating Manual. Trailer. Hilomast LLC 402 Chairman Court Debary FL32713

INSTALLATION, SERVICE AND MAINTENANCE INSTRUCTIONS Y-FILTER 83700

INSTALLATION, SERVICE AND MAINTENANCE INSTRUCTIONS Y-FILTER 83700

abc INSTALLATION, OPERATION, & MAINTENANCE MANUAL ADDENDA 210 MKII LOW TEMPERATURE CELL SAMPLER

MG12K24T60V4 Mechanical Grapple

Bubble King. User Manual

04979, 04980, 04981, 04982, 04983, 04984, 39054, 39055, 39056, 39057, 39225, 81459,

Data Sheet Manual. Vacuum Lifters

Standard Timer Connectors

Instruction Booklet for the Installation, Operation and Maintenance of Type 5-15 kv VCP-WG Vacuum Circuit Breaker 4000A MiniMod

Crane Forks. Introduction. Important Notes. Key Benefits. User Guide

Jeep Wrangler Heavy Duty Drag Link Installation Instructions

FIREFIGHTING EQUIPMENT

MV3-E Series Installation and Operation Manual for Hybrid Engine Controls

Ironman (Standard and LUL)

Landmark Rooftop Packaged Units

3-Wheel Aluminium Rollator. User Manual.

Instruction Manual. Pneumatic tank contents gauge Unitel # Distributed by

Safety Clamp Operation Manual

R310, R320, R330, R340 & R350 Product Manual. Compass Chair. R310, R320, R330, R340 & R350 Product Manual

LOAD SAFETY SERIES Information Sheet

STRUT SPRING COMPRESSOR

Bubble Machine. User Manual

Before equipment use, please read this operation manual carefully. Serial Number: Date Purchased:

TECHNICAL DOCUMENTATION

Tension Control Unit Type Product Manual EUROTHERM DRIVES. Copyright Eurotherm Drives Limited Printed in England HA Issue 3

TSS Tool Stand. Installation and Operation Manual. Document #:

Warning. Document ref: A October 2015

MAINTENANCE PLAN FOR RLB20 RAIL BEAM

Eazidraw Cordless. Installation & Set Up Instructions. Electric Blinds & Curtains

HEAVY DUTY TROLLEY JACK. Operation Manual

MECHlift ML 220 Bin Lifter

Slinger/signaller Note: It is recommended that you read the Supporting Information page before you read this factsheet.

Hydraulic Fittings. Design, Manufacture, Distribution

British Autogard Ltd 2 Wilkinson Road, Love Lane Industrial Estate, Cirencester, GL7 1YT, UK Tel: Fax:

Getz Equipment Innovators 450 lb Portable / Wheeled Unit Dry Chemical Fill System Part No: 3G0061/3G0063

3M Ladder Kit 3M710/MS 2 -TMK-LK

CPCS renewal test factsheet

K710 Product Manual. Support Station. K710 Product Manual

ABACO MACHINES OPERATION MANUAL STONE/STEEL/GLASS/WOODS LIFTER (ASSGWL20) ABACO MACHINES (USA)

Position Paper. Telehandler Use: Lifting Suspended Loads

User Guide Rail Scooter

12110BESTPLACE CINCINNATI,OHIO PHONE FAX

OPERATION & MAINTENANCE INSTRUCTIONS

Standard Reference Document OPERATING STANDARD 2 SELECTIVE COUPLINGS FOR ROAD TANKERS DEDICATED TO AVIATION FUEL OS 2

Two shift operation power plants. Stop valves. Body materials

MECHlift ML 150 Bin Lifter

Installation and user s guide H A. TP20 probe for FARO arm

Backs and Support OWNER MANUAL. J&L Hardware. TFB Hardware J&L Owner s Manual

Advancement Chair. R901, R902, & R903 Product Manual

MGF TECHNICAL FILE TRENCH SHEETS. Description. Product Notes.

Preventive Maintenance Become 100% competitive.

The Teconnex V Clamp

Lifting Points Rotating Ball-bearing De-centered Weldable Screw-on

Model 240K / 240KL Coupling

(UK) Date : January 2014

Adjustable Speaker Mount GRAVIS 12

WORKHOLDING SYSTEMS

Transcription:

User Manual H Frames Original Instructions Revision 1.3

Contents Contents: Introduction... 2 Exclusion of Liability... 2 Safety Instructions... 2 Assembly Examples... 4 Assembly... 5 Couplers... 6 Extensions... 7 H frames... 8 Tank Trap Adaptors... 9 Connectors... 10 Maintenance... 11 Contact Details... 12 1

Introduction Introduction The H Frames are part of a system designed to provide a safe flexible rigging method for suspending luminaires from truss or fixed tubes and barrels. This system can also be used with our Tank Traps to create a floor standing system. Using the popular conical truss connection method, parts from this range can be quickly assembled in a variety of configurations. H Frame Tapered Pin Connector H Frame Tapered Pin Exclusion of Liability Using this product for any purpose other than that described in this manual is considered contrary to its designated use and the manufacturer cannot be held liable for any damage resulting from such use. Safety Instructions 1. Each component has been load tested, care must be taken not to exceed the SWL of the component or the SWL of the assembled structure. 2. It is recommended that Safety Bonds are used with this equipment. When Safety Bonds are used the user is responsible for: i) Ensuring the Safety Bond is of optimum length, i.e. in the event of failure, the drop distance is kept as short as possible. ii) Ensuring the Safety Bond is attached so that the mounting points are of sufficient strength to withstand the forces imposed by the falling load. 2

Safety Bonds Safety Bonds Doughty Engineering recommends the use of safety bonds when using the H frame range. It is recommended that a bond is used between the truss/barrel and between the luminaire and the bottom of H Frame. Safety bonds are not required at each joint. Slots are provided in the H frame range are 50 x 15mm and are large enough to accept a moving light hook from our range of safety bonds. Care must be taken to ensure the safety bond used at the top is rated to the weight of the whole system not just the luminaire. Doughty Engineering manufactures two bonds specifically for this system. T45852 'H' Frame Safety Bond with Quick Link - Silver SWL 200kg T45853 'H' Frame Safety Bond with Quick Link - Black SWL 200kg T45855 Safety Bond with Moving Light Hook - Silver SWL 36kg T45856 Safety Bond with Moving Light Hook - Black SWL 36kg Safety Bonds with Quick Link Safety Bond with Moving Light Hook Doughty Moving Light Hook 55mm 15mm 3

Assembly Examples Assembly Examples 4

Assembly Assembly When assembling the H frame parts note the pins and holes are all tapered. Care must be taken to ensure the tapered holes are positioned correctly to accept the tapered pins. Two tapered holes are provided to allow the coupler/clamps to be positioned parallel or at 90 degrees. It is common practice to use a nylon or copper hammer to assist the tapered pins. Nyloc nuts should be replaced after each use/installation. 5

Couplers Couplers Listed below is a range of clamps/couplers fitted with a connector enabling the H frames to be attached to the truss or pipe. Part No Description Tube Diameter T45800 T57000 with half connector - Silver Ø 48-51mm T45801 T57000 with half connector - Black Ø 48-51mm T45810 T58600 with half connector - Silver Ø 48-51mm T45811 T58601 with half connector - Black Ø 48-51mm T45815 T58100 with half connector - Silver Ø 48-51mm T45816 T58101 with half connector - Black Ø 48-51mm T45820 T57400 with half connector - Silver Ø 60-63mm T45821 T57401 with half connector - Black Ø 60-63mm T45825 T58860 with half connector - Silver Ø 48-51mm T45826 T588601 with half connector - Black Ø 48-51mm T45830 T58300 with half connector - Silver Ø 38-51mm T45831 T58301 with half connector - Black Ø 38-51mm T45835 T58500 with half connector - Silver Ø 48-80mm T45836 T58501 with half connector - Black Ø 48-80mm Other combinations are available - contact sales@doughty-engineering.co.uk for details Typical examples of coupler fitted with a half connector T45800 T45815 T45825 T45830 6

Extensions Extensions Extensions are available to extend an assembly. Slots are provided for Safety Bonds. Extensions are supplied with 2 x tapered pins and nyloc nuts. T45775 250mm Extension - Silver SWL 100kg T45776 250mm Extension - Black SWL 100kg T45780 500mm Extension - Silver SWL 100kg T45781 500mm Extension - Black SWL 100kg T45785 1000mm Extension - Silver SWL 100kg T45786 1000mm Extension - Black SWL 100kg T45790 2000mm Extension - Silver SWL 100kg T45791 2000mm Extension - Black SWL 100kg Coupler with Half Connector 250mm 1000mm 250mm Extension Connector 1000mm Extension Connector H Frame 7

H Frames H Frames The H Frames have been designed in two sizes: and can connected to make a ladder assembly. Slots are provided for Safety Bonds. T45900 H Frame small - Silver SWL 200kg T45901 H Frame small - Black SWL 200kg T45910 H Frame large - Silver SWL 200kg T45911 H Frame large - Black SWL 200kg H Frames are supplied with tapered pins & nyloc nuts. 415mm Ø48mm 275mm H Frame small 750mm 1000mm 860mm H Frame large Ø48mm 750mm 8

Tank Trap Adaptors Tank Trap Adaptors The Tank Trap adaptors enable a H frame to be floor mounted with a pair of Tank Traps T45757 T45758 T54250 Tank Trap Adaptor - Silver Tank Trap Adaptor - Black Tank Trap Tank Trap Adaptors are supplied with a tapered pin & nyloc nut. Tank Trap Adaptor 395mm T54250 - Tank Trap H Frame Tank Trap Adaptor T54250 - Tank Trap 9

Connectors Connectors T45750 T45755 T45756 M12 Half Connector Full Connector Tapered Pin & Nyloc Nut T45750 T45755 T45756 10

Maintenance Maintenance Maintenance must only be carried out by approved personnel. Approved personnel must make regular checks of the product. If you see any damage including cracks, deformation or missing parts, the product must be removed from service and returned to an Approved Service Agent for evaluation/repair. A full list of approved service agents can be found on our website. Approved personnel must carry out a visual and a function test before every usage. Approved personnel must carry out more detailed inspection and testing of the product on a regular basis depending on the usage of the product. Written records should be kept from the date the product was put into operation. Warning The installer/operator must read and understand the Instruction Manual before using the equipment. Operators shall be adequately instructed and fully understand the safe use of the equipment before use. Failure to carry out maintenance as necessary, including the replacement of parts to the correct standard could render this equipment unsafe and the manufacturer cannot accept any responsibility in this respect. Only use approved spare parts. Do not modify the equipment as this could lead to a critical failure. Do not use this equipment for a purpose for which it is not intended. This could lead to a failure of the equipment and a risk of falling objects. 11

Contact Doughty Engineering Ltd Crow Arch Lane Ringwood, Hampshire, BH24 1NZ Tel: +44 (0) 1425 478961 Fax: +44 (0) 1425 474481 email: sales@doughty-engineering.co.uk Web: Note: Whilst every effort has been made to ensure that the information contained within this manual is correct, Doughty Engineering does not accept any liability for errors or omissions. Specifications and technical data are intended for guidance purposes only and may vary. 12