Installation / Operation Manual

Similar documents
INDUSTRIAL WATER PROCESSING SYSTEMS CENTRAL BRINE DRUM INSTALLATION INSTRUCTIONS

5600 Control Valve. Bypass Piping Boss Inlet & Outlet. Distributor Tube and basket. Brine Well. Brine Line. Over-Flow (Optional) $1.

Fleck 2510 Manual Sediment Filter Installation & Start-Up Guide

65 Series. Valve Operation Manual

AQT-56 POWERFLO SERIES SERVICE MANUAL CONTROL VALVES

Clean Water Made Easy

Owner s Manual WARNING

ONE. Cartridge Tank Filters

ONE. Cartridge Tank Filters

ONE. Cartridge Tank Filters

AQT-275 SERIES SERVICE MANUAL CONTROL VALVES

INSTALLATION, OPERATING AND SERVICE MANUAL

Installation, Operation and Maintenance Manual

Owners Manual Installation Instructions. For Models PTCF PTCF PTCF

Installation and Operating Instructions

Installation For Service Only

Installation Instructions

Signature Series Filter Manual

DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS

Hydraulic Motors Repair Instructions

GTFLOW EXTENSION MANIFOLD ASSEMBLY INSTRUCTIONS

DISCONTINUED. Installation. Aerada 900 Series Futura Faucet. With Accu-Zone (AZ) Infrared Control

Provectr Plus Filter Manual

Installation / Operation Manual

Installation Instructions Light Commercial & Irrigation Water Pressure Booster System

HAYWARD FLOW CONTROL TBH SERIES TRUE UNION BALL VALVE INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

ONLINE WARRANTY INFORMATION CrystalQuest.com/warranty.html

Provectr Plus Filter Manual

HARMSCO Filtration Products BC6 Series

Installation, Operation and Maintenance Manual

5900e Carbon Filter Installation & Start-Up Guide

Repair Manual. Modular Direct Steam Kettle

OWNER S MANUAL D.E. CARTRIDGE. Installation Operation Parts. Models PCDE-30 PCDE-40

Nelsen Filtration Cartridge Systems

or OWNER S MANUAL MODEL R

Owner's Manual. Model: LS-PCO-100-GEM ( ) (100 Gallon Skid-Mounted High Pressure Sprayer) Technical Specifications. General Information

Owner s Manual Nitrate Series Salt Based Filter System

BNT 85 /185 Valve Operation Manual

215 Gallon Waste Oil Tank With Metering Pump Installation Instructions

OWNER S MANUAL. Model: TR-40-GAS ( ) (40 Gallon Lawn & Garden Trailer Sprayer w/5-nozzle Boom Assembly) Technical Specifications

Superior Water And Air

7500 Greensand Filter Installation & Start Up Guide

Welker Sampler. Installation, Operation, & Maintenance Manual. Model GSS-4HP

Installation Kitchen Faucet Filtration System Instructions GXK285JBL

Superior Water And Air OWNER S MANUAL Model 32-CL770 & 48-CL770

Iron Blaster System Owner s Manual

SUPPLEMENTAL MANUAL FOR THE INSTALLATION, OPERATION AND MAINTENANCE OF THE XL234 FILTER VESSEL

Value Super Filter Max Installation Manual

INSTALLATION INSTRUCTIONS

Scale Feeder Manifold Water Filtration System Instruction Manual

FLECK 2850S SERVICE MANUAL. waterpurification.pentair.com

INSTRUCTIONS AND PARTS LIST FOR MODEL FORCE 10DA and FORCE 25DA (Double Acting, Electrically-Operated Hydraulic Press)

AQT-56SE ELECTRONIC SERIES PROGRAMMING MANUAL CONTROL VALVES

Set-Up Instructions. for EC-VM400. Motorized Valves

DFA Series. Rainwater/Graywater Filtration Systems. Installation, Operation and Maintenance Manual DFM-2F-180 DFM-3F-180 DFM-3F-350

Jandy Pro Series NeverLube and Backwash Valve

MASTER. Water Conditioning Corp. Installation and Operation Manual. MCA Combination Series Residential Units

SIMPLEX PREMIUM WATER SOFTENER INSTALLATION AND USER GUIDE

WATER SOFTENER SEMI AUTOMATIC INSTALLATION & OPERATING INSTRUCTIONS. Serial No :

SmartChoice. Gen II itwin. Water Conditioning System. Installation, Operation, and Maintenance Manual. Installation, Operation, and Maintenance Manual

Chemical Free Iron Sulphur Filtration System Owner's Operation and Maintenance Manual

CARTRIDGE FILTER SYSTEMS OWNER S MANUAL

FILTER KIT EWF172 Watersentry VII KIT (Lead, Aesthetic Chlorine Taste & Odor & Particulate Class I Reduction) FOR COMMERCIAL USE ONLY

Installation Instructions

AGXCEL GX12i CHEMICAL INJECTOR 2% INJECTOR UNIT - PN# % INJECTOR UNIT - PN# E 6TH ST KEARNEY NE

General Operation. To set Time of Day. To set Time of Regeneration / Backwash

3.1 DISPENSER BLACK SHADOW SERIES. Tools Needed for Mounting SCS Dispenser Hammer

Installation and Operation Manual

Pulsar Fluoride Removal Filter

MrPEX 1 ½ " Brass Manifold Installation Guide

Owner s Manual. Calcite ph Neutralizer

Instructions. Certifications Chrome less spray Chrome with spray 10-K82-WNCH-AD-Z Chrome less spray 10-K82-WYCH-AD-Z Chrome with spray

VALVE AND PLUMBING KIT 2408TL LOADER AGCO & MASSEY FERGUSON TRACTORS

ADVANCE. Backwashing Filters and Tannin Filter. Installation Instructions & Owner s Manual

ASSEMBLY MANUAL SMC 2491 LOADER VALVE AND PLUMBING KIT INSTRUCTIONS KUBOTA TRACTORS

Reactr VS Installation / Operation Manual

Dual Flow Manifold Systems Instruction Manual

CENTURY EXTERNAL MIX GEL COAT SYSTEMS Models: CX2017HC-A and CX2017HC-B000000

DEMA Pro-Fill II Sink Dispenser

7-LX B 7-LX B 7-LX B 7-LX B 7-LX B

IWT 565 Series Valve Operation Manual

Be sure pins are actually seated in their respective slots before applying any pressure.

SINGLE ACTION FLUID PUMP

VALVE AND PLUMBING KIT INSTRUCTIONS SMC 84Q & 2408 LOADERS NEW HOLLAND TRACTORS MODEL 2WD 4WD LESS CAB WITH CAB 1720 X X X 1920 X X X

Full Flow Drinking Water System Model: 3MFF100

Installation Guide. Single-Control Bath and Shower Trim A K T948, K T949, K T950 K 951, K 952

Isobar II Nitrate / Sulfate Manual

Dual/Triple Manifold Water Filtration Systems Instruction Manual

MrPEX 1 ¼ Stainless Steel Manifold. Installation Guide

Model Downlow & Uplow

Pre-Treatment Control Valve (Fleck 2850s) & Timer (Fleck SXT)

HARMSCO Hurricane Swing Bolt Water Filters Models: HUR 1X170FL, HUR 3X170FL HUR 5X170FL, & HUR 8X170FL

VALVE AND PLUMBING KIT NEW HOLLAND 7310 LOADER NEW HOLLAND TRACTORS

MODEL NO. UTL-60-7

Tools Needed for Mounting Cleá Filling Station

Model T Professional Series 1/2HP 2 YEAR WARRANTY SHALLOW WELL JET PUMP

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

Material required for drilled well application (indoor use only)

DEMA Pro-Fill I Sink Dispenser

ASSEMBLY MANUAL. Keep With Operator s Manual

Transcription:

Installation / Operation Manual

Installation Requirements Pressure Range: 10-150 psi Temperature Range: 40-120 F Max Service Flow Rate: 25gpm NOTE: Position filter on a level surface. Filter must be installed at least 10 feet ahead of the inlet to a water heater. Do not install in direct sunlight or in freezing temperatures. Step 1: Push on #9 Push Ball Valve to #8 Adapter Stem (see page 5). Make sure the knob on #9 is in the off position perpendicular with water flow. Step 2: Decide which of the provided connectors work best for your installation (straight or 90 ). Lubricate connector O-rings with a food grade silicone before installing on bypass. HAND TIGHTEN ONLY! Step 3: Take note of the water flow arrows and plumb in your incoming and outgoing water. Use Teflon tape only on connector threads. The use of other sealants can damage the threads. Step 4: Once plumbed in, insert the filter cartridge. (Instructions on page 3) Step 5: After filter cartridge is installed, slowly open inlet of bypass and allow tank to fill up. Pressing the top red button will help purge air out. Check for leaks. Step 6: Slowly open the outlet on the bypass and allow water to service. Open nearest faucet and run water for several minutes. Check for leaks. 2

Filter Cartridge Installation 1. Ensure o-rings are properly lubricated before installation. Insert filter into the filter adapter of the bottom drain assembly. 2. A filter this high is not installed properly. 3. A properly installed filter should sit below the seal area. 4. Ensure the top Pressure Release Cap Lid is installed to fully expose the retaining groove. 5. Install the angled lead tip of the retaining ring into the groove. 6. Working clockwise, push the retaining ring into the groove until the end snaps into place. Gently pull on lid assembly to seat o-ring. 3

Filter Cartridge Replacement 1. Turn both handles on bypass to bypass position (horizontal with the plumbing). 2. Remove top cover and relieve pressure in tank by pressing red button. 3. Attach 1/4 X 3/8 poly tubing to John Guest drain shut off and run to a suitable drain. Open drain shut off & let tank drain. 5. Install new cartridge (Instructions on page 3) 6. Close drain shut off. 7. After filter cartridge is installed, slowly open inlet of bypass and allow tank to fill up. Pressing the top red button will help purge air out. Check for leaks. 8. Slowly open the outlet on the bypass and allow water to service. Open nearest faucet and run water for several minutes. Check for leaks. 4. Remove snap ring and tank top from tank. Pull out old cartridge. 4

20 1 MF40, Monstr Flow 15 19 12 18 OR 17 16 13 14 2a 2b No. Part No. Description Qty 1 CT-CAP Cartridge Tank Cover 1 2 Z00840BBBK00 Cartridge Tank 1 a b c R-CTRETAINRING Cartridge Tank Retainer Ring 2 R-CTPRTOPCAP Cartridge Tank Top Cap 1 R-CTPRBOTCAP Cartridge Tank Bottom Cap 1 3 R-CT2.5ADAPTER-BP Cartridge to Upflow Body Adapter 1 4 20015X007 Upflow Body Union Nut 1 5 20015X008 Tank Adapter 1 6 20015X010 Upflow Body 1 7 20017X294 Verticle Elbow Adapter Set.5 a 20017X295 Verticle Elbow Adapter Set, Threaded.5 8 GA-S06604163 Adapter Stem 1 9 20015X022 3/8" Push Ball Valve 1 10 20015X006 Solvent Weld Adapter 2 11 20015X019 1" Sch80 PVC Pipe, 22" 1 12 70000X033 Side Pipe Support 1 13 70000X034 Pipe Bracket Retainer 1 14 N/A Large Zip Tie 1 15 SC11 Screw 2 16 20017X291 Solvent Weld Adapter 2 17 20017X283 Bypass 1 18 20017X284 1" NPT Elbow Set 1 19 20017X289 1" NPT Straight Set 1 20 L-MF CAP LABEL 1 IN 11 3 2 INLET OUTLET OUT 2c 10 9 8 7a 7 4 5 6 NOTE: Flow direction arrows on bypass are incorrect for this filter application. Plumb unit opposite of arrows. 5

Typical Installation Drawing Monstr Flow Setup (Incoming Water from Left-Side) NOTE: Flow direction arrows located on bypass valve are backwards. When viewing the back of the unit the inlet is on the left and outlet to the right. HARD WATER TO OUTSIDE FAUCETS GROUNDED & UNSWITCHED 115- VOLT OUTLET SERVICE HOT SOFT WATER CITY WATER INLET WATER METER COLD SOFT WATER PRESSURE RELIEF VALVE (To drain) SOFTENER if required RELIEF VALVE MUST BE INSTALLED PRESSURE TANK DRAIN LINES BRINE TANK WATER HEATER WELL INLET PUMP REQUIRED 4" AIR GAP

7

710 Orange Street Ashland, OH 44805