A.A. Calibration Pvt. Ltd., 13-C/18, Vasundhara Haat, Vasundhara, Ghaziabad, Uttar Pradesh. Discipline Mechanical Calibration Issue Date

Similar documents
Accurate Labs, 311, 312 Govinda Complex, GIDC Char Rasta, Vapi, Valsad, Gujarat. Discipline Mechanical Calibration Issue Date

Discipline Mechanical Calibration Issue Date Certificate Number C-0393 Valid Until Last Amended on - Page 1 of 6

Calitron Calibration Laboratory, U1: 207, Kohinoor Arcade, Tilak Chowk, Nigdi, Pune, Maharashtra

Alcalab Private Limited, 3rd Floor, Ashiana Trade Centre, Adityapur, Jamshedpur, Jharkhand. Discipline Mechanical Calibration Issue Date

Discipline Mechanical Calibration Issue Date Certificate Number C-0752 Valid Until Last Amended on - Page 1 of 6

Hi-Tech Calibration, 307, 3rd Floor, Govinda Complex, Char Rasta, Vapi, Gujarat. Discipline Mechanical Calibration Issue Date

Institute for Design of Electrical Measuring Instruments, Swatantryaveer Tatya Tope Marg, Chunabhatti, Sion, Mumbai, Maharashtra

Discipline Mechanical Calibration Issue Date Certificate Number C-0751 Valid Until Last Amended on

Accurate Measurements, Plot No.103, D Block, Meethapur Ext., Badarpur, New Delhi. Discipline Mechanical Calibration Issue Date

Discipline Mechanical Calibration Issue Date Certificate Number C-0208 Valid Until Last Amended on

Caliber Gauges & Instruments Laboratory, S. No. 14/1, Dattadigamber Soc. B, Warje Jakat Naka, Pune, Maharashtra

Cal-Tech Calibration Services Pvt. Ltd., Flat No.8, Avadhut Heights, Anand Nagar, Sinhgad Road, Pune, Maharashtra

ICL Calibration And Testing Services, SCO - 37, Ground Floor, Sector-12, Panchkula, Haryana. Discipline Mechanical Calibration Issue Date

Q-Tech Engineering Services, S-134, C/o, Precision Engineering Works, MIDC, Bhosari, Pune, Maharashtra

Central Mechanical Engineering Research Institute, Mahatma Gandhi Avenue, Durgapur, West Bengal

Autocal Solutions Pvt. Ltd., Plot No. BG-74, Gala No. 1 & 2, Jai Tulja Bhavani Indl. Premises, Telco Road, MIDC Bhosari, Pune, Maharashtra

QA Tech (A Division of GMP Technical Solutions Pvt. Ltd.), L-73, Verna Industrial Estate, Verna Salcette, Goa

CERTIFICATE OF ACCREDITATION

Shriram Institute For Industrial Research, 14-15, Sadarmangala Industrial Area, Whitefield Road, Bangalore, Karnataka

Page : 1 of 16. FIELD OF TESTING : Calibration and Measurement CALIBRATION & MEASUREMENT CAPABILITY EXPRESSED AS AN UNCERTAINITY *


Metrology Laboratory, CMTI, Central Manufacturing Technology Institute, Tumkur Road, Bangalore, Karnataka Accreditation Standard ISO/IEC 17025: 2005

Rev /07/2015 CATALOGUE - CALIBRATION SERVICES 1


TEST AND CALIBRATION SERVICES Ensuring quality and reliability.

Schedule. 300 mm to 600 mm 600 mm to 1000 mm inch to 12 inch

Certificate of Accreditation

Price List. Calibration Fee

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Welcome to Garber C O R P O R AT E O V E R V I E W

Schedule. 200 C to 400 C. 400 C to 660 C C to 800 C C to 1300 C C to 1200 C. 0 C to 1700 C. 0 C to 1700 C.

CERTIFICATE OF ACCREDITATION

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

IEC SYSTEM FOR CONFORMITY TESTING AND COMMITTEE OF TESTING LABORATORIES CERTIFICATION OF ELECTRICAL EQUIPMENT

HA Thickness Gauge IS:2386 (part 1)- 1963

Height Master Page 345. Check Master Page 349. Calibration Tools Page 354

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

SCOPE OF ACCREDITATION TO ISO/IEC & KS Q ISO/IEC

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Hellenic Accreditation System. Annex F2/17 to the Certificate No SCOPE of ACCREDITATION

PROMPT ENGINEERING P.O. BOX BARWA VILLAGE, WAKRA, BUILDING NO. 6 SHOP NO. 19 AND 20 DOHA QATAR

Measuring. Affordable. Effective. Instruments

Ref:CL/Mech./ Cal /BID-01(13-14) Date: 10 July 2013

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z


SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Scope of Accreditation For Global Instrumentation Services, LLC 523 N. Sam Houston Parkway E, Suite 230 Houston, TX Gavin Lewis

Gear Measurement. Lecture (7) Mechanical Measurements

Certificate of Accreditation

Small Tool Instruments and Data Management

Small Tool Instruments and Data Management

TRI-STATE INSTRUMENT SVC, INC

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

Annex to the Accreditation Certificate D-K according to DIN EN ISO/IEC 17025:2005

Standard Scales SERIES 182 Made of Low-Expansion Glass. Working Standard Scales SERIES 182 E-32

Certificate of Accreditation

Certificate of Accreditation

Certificate of Accreditation

UGANDA NATIONAL BUREAU OF STANDARDS NATIONAL METROLOGY LABORATORY

CALIBRATION SYSTEM CERTIFICATE

Certificate of Accreditation

ACCREDITATION FACILITY AUDIT CHECKLIST

SAMPLES GAUGES. Tolerances OUR SPECIAL OFFER: PLUG GAUGES WITH REQUIRED FIT OR INDIVIDUAL TOLERANCES ACCORDING TO YOUR SPECIFICATIONS

Pressure Instrument Testing Equipment

TEST FACILITIES AT SQAE(GS), KOLKATA LAB STORES DTE Name of Estt with address, Name of Srl.No Nodal officer and contact No

Equipment List. Tenere Inc. 700 Kelly Avenue, Dresser, WI General Inquiries: Sales Inquiries:

Faculty of Mechanical Engineering B.E. Mechanical Engineering (Sandwich) (R 2013) Semester III. Requirements for a batch of 30 students

POLYLAB Price List September

Phone:

REQUEST FOR QUOTATION

0280 / 0281 Vernier depth gauges

Transferpette. Testing Instructions (SOP) 1. Introduction. May 2009

Small Tool Instruments and Data Management

CALIBRATION PRICE LIST

Gauge Blocks - Reference for Precision

Product Range. Pages

Laboratory Equipment. Tel: +44 (0) u Fax: +44 (0) u

Transferpette. Testing Instructions (SOP) 1. Introduction. October 2013

Berufsweltmeisterschaft Calgary - Canada 1. Sep- 6. Sep 2009

Carl Stuart Ltd. Tallaght Business Park, Whitestown, Dublin 24. Calibration Laboratory Registration number: 270C

ANAUM INTERNATIONAL ELECTRONICS LLC. Test and Measurement Calibration Services Test Bench.

Check Points. for Measuring Instruments

Measuring tools. Accuracy in measurement. Test-safe use. Multiple versions. Torque wrenches. Vernier calipers Spirit levels Mason s profiles

Fluoro plastic products

A SURVEY OF OUR KNOW-HOW : PETROLEUM GLASSWARE VISCOMETER TUBES

PRICE SCHEDULE FOR LABORATORY EQUIPMENT Goods and related Services offered within Sri Lanka (in Sri Lankan Rupees)

YOUR MITUTOYO PROMOTION

Digimatic Caliper Gages SERIES 209 Internal Tube Thickness Measurement Type

TopPette Mechanical Pipettes

SPECIFICATION SHEET Pulse tool / Impact Wrench Testing System MODEL : IWT-101

Certificate of Accreditation

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

200 m IP67. Partner for specialist retailers. Precision Offers. In Germany at home in demand worldwide. valid until

Brinda Industries. Process Measuring Instruments.

REMOVAL OF ALTERNATOR

ASTM D4. Bitumen Content Qty. Model Description. Related Standards: ASTM D370, E177

Faculty of Mechanical Engineering B.E. Marine Engineering (R 2013) Semester III FLUID MACHINERY LABORATORY

An ISO 9001 : 2008 Certified Company J-SIL LABORATORY GLASSWARE. Made from Borosilicate 3.3 Glass PRICE LIST. Manufactured by :

Transcription:

Last Amended on 02.09.2014 Page 1 of 10 I. DIMENSION 1. VERNIER CALIPER $ L.C. 0.01mm 0 to 300 mm 0 to 600 mm 0 to 1000 mm 8 µm 14 µm 16 µm, Slip Gauge Accessories, Gauge Block L.C. 0.02 mm 0 to 1500 mm (Inside Only 1000 mm) 24 µm 2. EXT. MICROMETER $ L.C. 0.001mm Up to 100 mm 100mm to 300 mm 300mm to 600 mm 1.3 µm 2.5 µm 10 µm, Gauge Block & Slip Gauge Accessories 600mm to 1000 mm 17 µm 3. INTERNAL MICROMETER $ 5 mm to 50 mm 50 mm to 300 mm Up to 1500 mm 6 µm 12 µm 20 µm M-88 & M-10, Gauge Block, M 8, Slip Gauge Accessories 4. PLUNGER TYPE DIAL L.C. 0.001 mm L.C. 0.001 mm Up to 25 mm 25 mm & Upto 100 mm 1.4 µm 7.2 µm Using Dial Calibration Tester, Slip Gauge Set M-88 & Micro Indicator with Comparator Stand

Last Amended on 02.09.2014 Page 2 of 10 5. LEVER TYPE DIAL L.C. 0.001 mm L.C. 0.002 mm 0 to 0.140 mm 0 to 0.2 mm 1.3 µm 1.65 µm Using Dial Calibration Tester 0 to 1 mm 6 µm 6. HEIGHT 0 to 300 mm 0 to 600 mm 0 to 1000 mm 8.7 µm 10 µm 15 µm M-88, Gauge Block M-8 Puppy Dial 7. DIAL THICKNESS L.C. 0.001 mm 0 to 1 mm 0 to 25 mm 1 µm 6 µm M - 88 8. BORE Up to 450 mm 1 mm Travel Only 4 µm Using Dial Calibration Tester & Dial Gauge 9. SNAP Up to 100 mm 2.6 µm M 88 10. PLAIN PLUG Up to 150 mm 2.2 µm Using Micro Indicator with comparator stand & Slip Gauge Set M-88 11. PLAIN RING 10mm to 100 mm 100mm to 200 mm 3 µm 3.8 µm M 88 & Slip Gauge Accessories

Last Amended on 02.09.2014 Page 3 of 10 12. FEELER Up to 1 mm 1.4 µm Using Digital Micrometer 13. MEASURING PIN SET $ Up to 25 mm 1.4 µm Using Digital Micrometer 14. STANDARD THICKNESS FOIL $ Up to 1 mm 1.4 µm Using Digital Micrometer 15. DEPTH 0 to 300 mm 8.2 µm M- 88 & Gauge block M 8 16. DEPTH MICROMETER $ L.C. 0.001 mm Up to 100 mm Up to 300 mm 1.2 µm 6 µm M- 88 & Gauge block M 8 17. DIAL INSIDE CALIPER $ L.C. 0.001mm Up to 135 mm 8 µm M 88 & Slip Gauge Accessories 18. ELECTRONIC PROBE $ L.C. 0.0001 mm Up to 25 mm 1.3 µm Using Micro Indicator with Comparator Stand & Slip Gauge Set M-88 19. DIAL CALIBRATION TESTER $ L.C. 0.002 mm Up to 25 mm 1.23µm Using Micro Indicator with Comparator Stand & Slip Gauge Set M-88

Last Amended on 02.09.2014 Page 4 of 10 20. ANGLE PROTRACTOR, BEVEL PROTRACTOR, COMBINATION SET $ L.C. 5 min Up to 360 o 4.0 minute Using Angle Gauge L.C. - 1 o 0 to 180 o 35 minute 21. THREAD PLUG Up to 100 mm 2.1 µm Using Measuring Wire & Digital Micrometer 22. MICROMETER HEAD L.C. 1 µm 0 to 50 mm 1.3 µm Using Micro Indicator with comparator Stand 23. 3 POINT MICROMETER $ L.C. 1 µm 0 to 100 mm 4 µm Using Plain Ring Gauge Set 24. V ANVIL MICROMETER $ L.C. 1 µm L.C. 10 µm 0 to 50 mm 0 to 50 mm 2.4 µm 7 µm Using Plain Plug Gauge Set 25. V BLOCK $ Parallelism Flatness Symmetry 150mm x 150mm x 150 mm 2.1 µm Using Puppy Dial & Slip Gauge Set M-88 26. STEEL SCALE $ 0 to 1500 mm 0.06 L mm L in Meter Using Length Measuring Machine

Last Amended on 02.09.2014 Page 5 of 10 27. MEASURING TAPE $ 50 mtr 0.06 L mm L in Meter Using Length Measuring Machine 28. THREAD MEASURING WIRE SET $ Upto 6.35 mm 1.4 µm Using Digital Micrometer 29. LENGTH BAR $ 0 to 500 mm 7 µm Using Dial Calibration Tester, Slip Gauge Set M-88 & Gauge Block M-8 30. FORD CUP $ Only Orifice Dia 4mm to 10 mm 11.5 µm Using Digimetic Vernier 31. PISTOL CALIPER $ L.C. 0.1 mm 0 to 100 mm 70 µm M 88 32. COATING THICKNESS L.C. 1 µm 0 to 1200 µm 1.713 µm Using Standard Thickness Foil 33. ANGLE Up to 90 11 sec Using Profile Projector 34. RADIUS Up to 25 mm 3 µm Using Profile Projector 35. SPRIT LEVEL $ L.C. 10 µm/m 200mm X 200 mm 12.08 µm/m Using Mini Level NT & Comparator Stand 36. CUBE MOULD $ 300mm X 300mmX 300 mm 12.5 µm Using Digimatic Vernier

Last Amended on 02.09.2014 Page 6 of 10 37. FLAKINESS Upto 63 mm 10 µm Using Digimatic Vernier 38. ELONGATION Upto 63 mm 10 µm Using Digimatic Vernier 39. VICKET APPARATUS $ 0 to 50 mm 578 µm M-88 40. TEST SIEVES $ Upto 1 mm Above 1mm to 100 mm 5 µm 10 µm Using Profile Projector Digimatic Vernier 41. ULTRASONIC THICKNESS Upto 200 mm 75 µm M-88 42. GLASS SCALE $ 0 to 150 mm 58 µm Using Profile Projector 43. PROFILE PROJECTOR X & Y Axis and Angular Upto 150 mm Upto 360 2 µm 42 sec M-88 & Angle Gauge 44. SURFACE PLATE All Size 2x m L & W in mm Using Mini Level NT 45. BENCH CENTER 600 mm 7.0 m Using Mandrel and Puppy Dial II. ACCELERATION & SPEED Upto 25000 RPM 0.18 % FSD Using Dig. Tachometer 1. RPM METER/ TACHOMETER # Calibrator With Dig. Tachometer

Last Amended on 02.09.2014 Page 7 of 10 III. ACCOUSTICS 1. SOUND LEVEL METER $ 94 db & 114 db 2 db Using Sound Calibrator IV. PRESSURE AND VACCUM 1. INDUSTRIAL PRESSURE GAUGE/ TRANSDUCERS WITH INDICATOR # 0 to 700 kg/cm 2 0 to 30 kg/cm 2 0 to 20 kg/cm 2 0.3% FS 0.4% FS 0.43% FS Using Digital Pressure as per DKD-R-6-1 2. MAGNEHLIC GAUGE 0 to 200 mmwc 0.37% FS Using Polltech Calibrator as per DKD-R-6-1 3. PRESSURE GAUGE 0 to 300 mmhg 0.66 % FS Using Polltech Calibrator as per DKD-R-6-1 4. VACUUM GAUGE -760 to 0 mmhg 1.0 % FS Using Digital Pressure Gauge as per DKD-R-6-1 V. TORQUE 1. TORQUE WRENCH $ 20Nm to 100 Nm 100 Nm to 1000 Nm (Type 1- Class B & Type II Class A, Class B) 1.4 Nm 9.7 Nm Using Electronic Torque Tester

Last Amended on 02.09.2014 Page 8 of 10 VI. VOLUME 1. MICRO PIPETTE $ 10 µl to 100 µl 0.06 µl Using Digital Weighing 100 µl to 1000 µl 0.06 µl Balance, Standard Weight & Distilled Water. By Gravimetric Method 2. GLASS PIPETTE $ 1 ml to 10 ml 0.08 µl Using Digital Weighing >10 ml to 25 ml 0.104 µl Balance, Standard Weight & Distilled Water. By Gravimetric Method 3. BURETTE $ 1 ml to 10 ml 0.08 µl Using Digital Weighing >10 ml to 50 ml 0.163 µl Balance, Standard Weight & Distilled Water. By Gravimetric Method 4. MEASURING 1 ml to 10 ml 0.09 µl Using Digital Weighing CYLINDER $ >10 ml to 50 ml 0.12 µl Balance, Standard Weight & Distilled Water. >50 ml to 100 ml 1.60 µl By Gravimetric Method >100 ml to 1000 ml 12.5 µl 5. MEASURING FLASK, MEASURING JAR, BEAKER $ 1 ml to 10 ml >10 ml to 50 ml >50 ml to 500 ml >500 ml to 5000 ml 0.09 µl 0.12 µl 1.52 ml 1.54 ml Using Digital Weighing Balance, Standard Weight & Distilled Water. By Gravimetric Method VII. MASS 1. SPRING BALANCE L. C. : 10 g 0 to 100 kg 16.2 g Using SS Weight F2 Class L. C. : 500 g 0 to 100 kg 800 g

Last Amended on 02.09.2014 Page 9 of 10 2. WEIGHING BALANCE L. C. : 0.1 mg 0 to 200 g 7 mg Using SS Weight of F1 Class, L. C. : 1g 0 to 20 kg 1.5 g F2 Class, M1 Class L. C.: 1 g 0 to 100 kg 14 g L. C. : 10 g 0 to 200 kg 65 g 3. WEIGHTS (CONVENTIONAL MASS) 1mg 0.06 mg Using Standard Weights 2mg 0.06 mg (F1 Class) & Precision Balance 5mg 0.06 mg By Substitution Method 10mg 0.06 mg 20mg 50mg 100mg 200mg 500mg 0.06 mg 0.09 mg 0.07 mg 0.08 mg 1 g 2g 5g 10g 20g 50g 100g 200g 500g 0.29 mg 1.15 mg 0.058 g 1 kg 0.059 g

Last Amended on 02.09.2014 Page 10 of 10 2kg 5kg 10kg 0.059 g 0.422 g 0.454 g * Measurement Capability is expressed as an uncertainty ( ) at a confidence probability of 95% $ Only in Permanent Laboratory Only for Site Calibration # The laboratory is also capable for site calibration however, the uncertainty at site depends on the prevailing actual environmental conditions and master equipment used.