Darryl R. Rose VP Marketing Energex Inc.

Similar documents
PFI Standard Specification for Residential/Commercial Densified Fuel 18-June-2008

PFI Quality Assurance/Quality Control (QA/QC) Program for Residential/Commercial Densified Fuels

IGS-M-CH-051-1(0) Jan مصوب. Approved IGS. Molecular Sieve, Type 3A

Class 1 Crushed rock ballast for use primarily on main line track. Class 2 Crushed rock ballast for use only on other than main line track.

RECYCLABILITY EVALUATION PROTOCOL FOR PE FILMS

DIVISION OR ACTIVITY. API Spec 10A. January 21, 2014

Control Panel...3 Special Key Functions...4 Switching From Grams to Ounces...4 Calibration...5 Automatic Gauge Calibration...11

Renewable Fuels Association One Massachusetts Ave. NW Suite 820 Washington, DC Telephone: (202) Fax: (202)

Fibertec M6 Crude & Detergent Fibre Solution

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR PAVEMENT RIDE QUALITY (MEAN ROUGHNESS INDEX ACCEPTANCE CRITERIA)

Advance - Elevating De Dusting Machine.

European new pellets standards Case non-woody pellets, 4 May 2010, Lyon

MADMax Moisture and Density Interface: Quick Start Guide

Control Panel...3 Special Key Functions...4 Switching From Grams to Ounces...4 Calibration...5

Fibertec 8000 Fully automated Crude and Detergent Fibre analysis

Vibratory Sieve Shaker AS 300 control

FURNACES. Includes Gas Flowmeter and Manifold! F (15) 73 FB cu. ft. (45)

PSD & Moisture Content (71) PROFICIENCY TESTING PROGRAM REPORT

Healthweigh. Rice Lake Weighing Systems

SUMMARY. St-jean-sur-richelieu, January 15th 2016 Client: America s heat Project: PI-20114

International Journal of Material Science Innovations Volume 03, Issue 02, Pages 60-67, 2015

Analysis of Total Suspended Particles (TSP) and Total Organic Carbon (TOC) in Air Samples:

Meinzer II TM. Testing Sieve Shaker

T.O. 33K CALIBRATION PROCEDURE FOR CLASS WEIGHTS M2 (OIML), C (CIRCULAR 3), T (CIRCULAR 547), F (HB105-1), 6 (E617) AND CDI 2000

SMOOTHWALL BINS SMOOTHWALL BINS WESTERN. meridianmfg.com

United States Stove Company Project # Model: KP60 AKA: AP60, VG60 Type: Pellet-Fired Room Heater May 31, 2018

Combustion and Boiler Performance Assessment of Kardia Power Plant

SECTION 602 PORTLAND CEMENT CONCRETE PAVEMENT SMOOTHNESS

Standard Classification System for Carbon Blacks Used in Rubber Products 1

solventless, solvent-based & monocomponent mixers and metering units for lamination

Biodiesel. As fossil fuels become increasingly expensive to extract and produce, bio-diesel is

Page. 1.0 Overview & Operating Principle Operating Elements Quick Start Instructions Calibration Notes...

2017 Local Roads Workshop Local Agency HMA Acceptance Specification

6.0 SPECIFICATIONS CONTENTS. Calibration. According to factory procedureeeeeeeeeeeeeee Accuracy*

United States Stove Company Project # Model: Breckwell SP1000 Type: Pellet-Fired Room Heater July 25, 2018

WHITE PAPER. Preventing Collisions and Reducing Fleet Costs While Using the Zendrive Dashboard

Tex-614-J, Testing Epoxy Materials

Excellence Level. Excellence XSR Balances Discover Efficiency in Daily Weighing

TORQUE TESTERS FLEXIBLE-BEAM AND TORSION-BAR TYPES 5 OZ-IN TO 1000 LB-FT THIS PUBLICATION SUPERSEDES NAVAIR 17-20MU-03 DATED 1 MAY 1994

Extrusion Plastomelter -Standard Operating Procedure [Updated June 30, 2015]

NPS Series. Pallet Jack Scale Operator s Guide (V1611)

METHOD OF TEST FOR ABRASION OF COARSE AGGREGATE BY USE OF THE LOS ANGELES ABRASION TESTING MACHINE

Feed material Measuring range* Sieving motion Max. batch / feed capacity powders, bulk materials, suspensions 25 µm mm throwing motion with angu

LOPEZ LABS CO-OPERATIVE. heatkit.com/html/lopez.htm 1.) SUMMARY OF 87 MASONRY HEATER EMISSIONS TESTS 2.) SUMMARY OF 14 MASONRY HEATER EMISSIONS TESTS

ASTM D Determing Aerobic Biodegradation of Plastic Materials Under Controlled Composting Conditions. Work Order #:

WATER SOFTENER SEMI AUTOMATIC INSTALLATION & OPERATING INSTRUCTIONS. Serial No :

Precision Balances WEIGHING WITH EXPERIENCE

ECscan10H Pocket Conductivity Tester. Instruction Manual BANTE INSTRUMENTS LIMITED

HA Thickness Gauge IS:2386 (part 1)- 1963

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR PAVEMENT RIDE QUALITY (IRI ACCEPTANCE CRITERIA)

ON-FARM EXPERIENCE WITH SWINE LIQUID FEEDING: GROW- FINISH PIGS

Prepared for: Prepared by: 4005 Port Chicago Highway Concord, California

RESIDENTIAL SOLID WASTE RFP DRAFT

THUNDERBIRD. Agricultural Weighing Systems SS1000 Instructions

1.0 Introduction Mounting Procedure Verifying Calibration Accuracy Specifications Tension Ranges...

WIM #40 US 52, MP S. ST. PAUL, MN APRIL 2010 MONTHLY REPORT

Tex-614-J, Testing Epoxy Materials

Determination of chlorine/chlorides using MWD- XRF

Session IV: Value chains, sustainability, standardisation Part 3: Standardisation

The Study Of Briquettes Produced With Bitumen, Caso 4 And Starch As Binders.

TEST FACILITIES AT SQAE(GS), KOLKATA LAB STORES DTE Name of Estt with address, Name of Srl.No Nodal officer and contact No

UGANDA NATIONAL BUREAU OF STANDARDS NATIONAL METROLOGY LABORATORY

Monitor Chlorine in Crude at Sub-ppm Levels

ISO 659 INTERNATIONAL STANDARD. Oilseeds Determination of oil content (Reference method)

WIM #39 MN 43, MP 45.2 WINONA, MN APRIL 2010 MONTHLY REPORT

All you need for sieving

Certificate of Accreditation

Chariton Valley Biomass Project Iowa Switchgrass Cofiring Update

PRINTOUT MAY NOT BE UP-TO-DATE; REFER TO METRO INTRANET FOR THE LATEST VERSION

Larson Systems Inc. V200, V750 and V1500 Digital Valve Spring Tester User Manual. Current for Software Version 6.9

QUALITY ASSURANCE & LAB ACCREDITATION

2017 Solid Waste Rates & Fees

THREE RANGE DS METERS Operation Instructions

7.09 ULTRASONIC ANALYZER

CAUTION 7.0 WARRANTY CONTENTS. 1.0 Overview... 2

CarePacs. Traceable Balance Testing for Secure Weighing Processes

OPTIMISING SEWAGE PUMPING STATION PERFORMANCE

Copyright Statement FPC International, Inc

Evaluation of reed canary grass shredding and compacting properties

Bisnet Solutions for Tomorrow, Today! The Die Casting Process Planner. Users Manual. August 5, A Product By: Bisnet - 1 -

GL Ludemann Y-Strainers

Raptor XL500 Cone Crushers

Raptor XL900 Cone Crushers

The New Entris. Monolithic weigh cell for long-term high accuracy. Built-in applications and function keys for convenient operation

The Ultimate Critical Service TRIPLE OFFSET VALVE

ECscan40 Pocket Conductivity/TDS/Salinity Tester Instruction Manual

SIR Test Vehicles Comparison from a Cleaning Perspective

TSHR 7000 series TN-TS-TX analyzer

Improving Valve Fugitive Emissions Performance

ML4330 SIEVE SHAKER MANUAL

"Double Colored Man Tou" steamed buns, photo by Roy Chung Soft Red Winter Wheat Quality Survey

ECscan30 Pocket Conductivity/TDS Tester Instruction Manual

ISO/IEC ACCREDITED CALIBRATION LABORATORY

Long-Term Costs and Savings of Properly Rewound Motors

Laboratory Equipment. Tel: +44 (0) u Fax: +44 (0) u

Comparison of IG Testing Standard. IGMA Summer Meeting August 8, 2004

HIGH POWER MOTOR TEST SYSTEMS

Residential Waste Hauling Study CUSTOMER SURVEY RESULTS NOVEMBER 24, 2010

Article: Sulfur Testing VPS Quality Approach By Dr Sunil Kumar Laboratory Manager Fujairah, UAE

Closed Cup Flash Point Tester

Transcription:

Darryl R. Rose VP Marketing Energex Inc. Drose@energex.com

QA Overview A QA program starts at the front end and continues throughout the entire process: Every raw material supplier is qualified prior to purchase Every load is inspected and tested Automated processes in place to assure Quality All key process metrics are recorded and alarmed if they fall outside limits DAILY management review meeting which focuses on key parameters of past 24 hours Equipment is designed / modified to assure quality. For example, we have modified pellet mills so we cannot make a long pellet. Our finished product testing is just a confirmation of quality.

Summary of PFI Fuel Grade Requirements Table 1 PFI Fuel Grade Requirements Residential Commercial Densified Fuel Standards Fuel Property PFI Premium PFI Standard PFI Utility Normative Information, Mandatory Bulk Density (Pounds / Cubic Foot) 40.0 46.0 38.0 46.0 38.0 46.0 Diameter, Inches 0.230 0.285 0.230 0.285 0.230 0.285 Diameter, mm 5.84 7.25 5.84 7.25 5.84 7.25 Pellet Durability Index >= 96.5 >= 95.0 >= 95.0 Fines, % (at the mill gate) <= 0.50 <= 1.0 <= 1.0 Inorganic Ash, % <= 1.0 <= 2.0 <= 6.0 Length, % > 1.50 inches <=1.0 <=1.0 <=1.0 Moisture, % <= 8.0 <= 10.0 <= 10.0 Chloride, ppm <= 300 <= 300 <= 300 Heating Value NA NA NA Informative Only Not Mandatory Ash Fusion NA NA NA

Equipment Used Pellet Splitter

Bulk Density PFI Premium Grade Requirement: 40 46 Lbs/Ft.³ ASTM Standard ASTM E 873 Test Methodology: Sample size minimum 12 pounds Take a ¼cubic foot container, fill and tap 25 times from one inch Record results Testing Frequency Twice / Week

Equipment Used For Bulk Density Stainless Steel Box FA200 Analytical balance accurate to 0.0001 g. Holds 200 grams. Price $1700.

Pellet Diameter PFI Premium Grade Requirement: 0.230 0.285 Test Methodology Select five pellets randomly from pellet sample (using splitter) Using an approved caliper, measure all five and calculate and report average and range to 0.001. We report average not the range Testing Frequency Twice / Week.

Equipment Used Pellet Diameter Approx. $200. 12 Caliper, accurate to 0.001

Pellet Durability Index (PDI) PFI Premium Grade Requirement: >=96.5% Test Methodology Secure sample of at least 1,100 grams using pellet splitter and a bag of finished goods. We use 500 g Screen over 1/8 wire screen sieve to remove fines Weigh 500 grams (± 10 grams) to nearest 0.1 grams (IW) Tumble at 50 rotations per minute for 500 rotations. Re screen the tumbled sample, weigh the portion remaining on sieve and record whole pellet sample weight to 0.1 grams Compute Pellet Durability index (WPI / IW) Repeat with a second sample. We do not do the second test. Testing Frequency Twice per week following PFI standard. We use a slightly modified method twice per hour. The fuel comes direct from production not from finished goods.

Equipment Used for Pellet Durability Durability Tester. We can do 4 tests at the same time. Rotates at 50 RPM for 5 minutes. Approximate Cost $1700 $2,000.

Fines PFI Premium Grade Requirement: 0.5% Equipment Used 1/8 Wire screen sieve Test Methodology (there is also an alternate method): Secure a representative sample and reduce to min. 2.5 pounds using a sample splitter Using analytical balance weigh sample and record as initial sample weight to 0.1 gram Weigh receiving pan and record to 0.1 gram Attach 1/8 screen to pan and place sample on screen. Several individual screenings may be needed depending on sample size relative to screen size Screen by tilting side to side 10 times Remove screen and weigh and record weight of base pan with the fines to 0.1 grams Calculate and report the % of fines to 0.01% (weight of base pan with fines weight of base pan / initial sample weight) Testing Frequency Twice per week using finished product. Energex also tests once per hour from the production line.

Equipment Used for Fines Testing Scale in control room, used hourly Timer Sieve Shaker. Each sieve has a progressively smaller mesh screen from large at top to very fine at bottom. Set the timer and it shakes back and forth for predetermined period of time.

Inorganic Ash PFI Premium Grade Requirement: 1.0% ASTM Standard ASTM D 1102 Test Methodology: Select a small sample using pellet splitter Pulverize and place on a 40 mesh screen (0.0165 ) Select 2 grams randomly and place in crucible Place crucible into muffle furnace for 2 hours and 12 minutes bringing temperature to 600C. Weigh remaining ash Determine and record results Testing Frequency Twice / Week

Equipment Used for Ash Samples Muffle Furnace slowly ramps up to 600C. We can do 4 tests at a time. Approximate inside dimensions are 5 X 6 X 6.

Additional Equipment for Ash Testing 4 crucibles shown inside ½ sealable glass desiccator. The samples are cooled to room temperature and then weighed. Also, FA 200 analytical scale shown previously.

Also For Ash Testing Plate Mill. Dial to the right allows for wide range of adjustment. Very fine grind of pellets for ash testing. Also used for moisture testing. FA200 Analytical scale shown previously. Accurate to 0.0001 grams

Length, % > 1.5 PFI Premium Grade Requirement: 1.0% Test Methodology : Start with 2.5 pounds randomly selected from sample Hand sort to identify pellets over 1.5, using approved calipers or measuring block Determine and record weight of all pellets over 1.5. Additionally report the longest pellet over 1.5 We have no pellets over 1.50 Testing Frequency Twice / Week

Equipment for Measuring Length Same Caliper as Used for Pellet Diameter

Moisture PFI Premium Grade Requirement: 8.0% Equipment Used 3 units, $3,000 each Test Methodology Select a random sample using a splitter (approx 1 handful) Grind to a fine flour Select 4 grams Heat to 175C for 5 minutes Moisture % is determined and recorded. Testing Frequency Twice Per Week from finished goods. Additionally, wee do this twice per hour from the production line.

Equipment for Moisture Testing To the left scale which is calibrated weekly. To the right, moisture analyzers. In PA alone, we have 3 at a cost of $3,000 each.

Chlorides PFI Premium Grade Requirement: 300 ppm ASTM Standard ASTM E 776, ASTM D 4208 or ASTM D 6721 Test Methodology This test is not performed inhouse. Testing Frequency Twice Per Week. Quarterly by Energex

Heating value and Ash Fusion Heat value ASTM E 711 Ash Fusion ASTM D 1857 Both of these tests are performed by independent labs and are optionally reported.

Calibration and Standardization Caliper Before each test confirm accuracy of caliper my measuring a traceable gauge block that is between 80% and 120% of the anticipated fuel diameter. Balances and Scales Before each test, verify the balance or scale by using a calibration weight that is 50% to 150% of the anticipated fuel sample weight. The scale must be accurate to within 1%.

Summary One Manufacturer s Perspective Strengths Test frequency far in excess of requirements Quality Control Manager at each Plant Expensive high quality equipment Opportunities for Improvement Independent lab results are recorded but not compared to in house results. That will be changed. Chloride testing is well below required but we have never had a chloride problem in 19 years.