MAGNETIC TROFFER RETROFIT KIT

Similar documents
G2 MAGNETIC RETROFIT KIT

ECO EXT (DIMMABLE)

TRUET5 EXT (DIMMABLE)

SIRIUS ON/OFF SU OF50SUS PRODUCT SPECIFICATION PRODUCT DESCRIPTION CERTIFICATIONS & QUALIFICATIONS E DIMENSIONS. Tolerance Range : ± 10%

RTR Gen 3/ LED Troffer Conversion Kit

ROUND PENDANT LED HIGH BAY HP Gen. 2 SERIES

Replacement. Metal Halide CR2000. Product Wattage CCT Total Lumen Efficacy Voltage Frequency Base Installation Angle

LED HIGH BAY LINEAR HL SERIES GEN 2

LED Indoor Lighting Product Guide

Alloy LED: Delivering Continuous Innovation

SURFACE MOUNTED. Project. Type. Notes. culus Listed Type I.C.

4 Watt LED Bulb ENERGY BULBS MODELS: EST C pic 1. pic 2. pic 3. pic 4

LED Lighting. LED Reflector. LED Downlight. LED Tube. LED Plug-in Tube. LED Sensor Batten. LED Floodlight. LED Lighting

Super-high output LED high bay. Affordable replacement for up to 400W HID. RAIL RCLIGHTING.CA

Technical Requirements Table, v1.7

security ase100 (4ft) series (2' available) SURFACE / corner / wall / ceiling mounted security led luminaire high impact angled security luminaire

Strip Light Series Sell Sheet

Tove. High Performance Linear System Perimeter

75% ENERGY SAVINGS 200W-600W HID Light Replacement

RECESSED T-Bar & Drywall. Project. Type. Notes 23 15/16" 23 7/8" SIDE VIEW. culus Listed Type I.C.

T8 Retrofit. LED Tubes

RECESSED T-BAR & DRYWALL. Project. Type. Notes. 0.5 StepLens. StepLens

MEDMASTER DOWNLIGHT Luminaires for Surgical Applications

Specification Sheet: EcoPark LED Parking Garage Fixture. Indoor/Outdoor

Replacement. Metal Halide OB150S. Product Wattage CCT Total Lumen Efficacy Voltage Frequency Base Installation Angle

2X4 LED RECESSED TROFFER

ECO LIGHTING.

ECO-T LED RECESSED TROFFER USER MANUAL

L3PNL. RECESSED LED IC PANEL 1'x4', 2'x2', 2'x4' FEATURES AND SPECIFICATIONS DIMENSIONS OVERVIEW

LEDVANCE SPOTLIGHT XXL

REQUEST FOR PROPOSAL (RFP) # LED LIGHTING CONVERSION FOR SANTIAGO CANYON COLLEGE AND DISTRICT OPERATIONS CENTER

RECESSED T-Bar & Drywall. Project. Type. Notes 47 15/16" 47 7/8" 48" between T-Bar SIDE VIEW

NULB-5 Pro90 Series ILLUMINATING THE FUTURE...SINCE Ultra-Low Profile Linear LED Lightbar PLUS. Type Project Catalog No.

LED HIGH BAY - SL 150W 200W BENEFITS APPLICATIONS MARKETS

Tove. High Performance Linear System T-Grid Recessed

Tove. High Performance Linear System Recessed

FVT / LED Vapor Tight

Linear Replacement Lamps

FVH / LED Vapor Proof Highbay

Vigilante Series. Wallpack. We light your world

Specification Sheet: Eco Area Light. Outdoor. 177 Broad Street, 12th Floor, Stamford, CT T rvlti.com

TECHNICAL SPECIFICATIONS

LED HIGH BAY - EXT EXTENDED LIFE BENEFITS APPLICATIONS MARKETS

LED lighting system. We Brighten Your Brands.

Idaho Profile System - Trimless

Technical Application Guide for UP-SHINE LED Batten Light UP-DB W

Technical Application Guide for UP-SHINE LED Batten Light UP-DB W

Technical Application Guide for UP-SHINE LED Batten Light UP-DB W

Low profile frame is just 0.5" thick CONFIGURATIONS

Beams Beam angle: 120 Working temperature: -20 C ~ +45 C Storage temperature: -25 C ~ +65 C. Compliances DLC culus ccsaus listed for damp location

TRUEFIT LED TUBE.

Big Ass Light High Powered Fixture

LED Flat Panel Luminaires

LASER BLADE DOWNLIGHT - NEW CONSTRUCTION WITH HOUSING - INTEGRAL

Class I, Div. II Fluorescent Fixture - Emergency Battery Backup - Corrosion Resistant (Saltwater) -

Energy Solutions LED Accelerator Program

Part Number: BK - Black WT - White CS - Custom*

Utilibay UTB2 High Bay

31 SERIES Modular area fixtures. Replaces: 1000W HID

2 LED Designer Series

LED Flat Panel Luminaires

WALL MOUNT - DIRECT/INDIRECT

LASER BLADE XS. Power input: 7.5 to 31.5W (system wattage) Lumens: 150 to 750lm (for 3000K, 90CRI) Luminaire efficacy: Up to 23lm/W.

LED HIGH BAY - SL STANDARD LIFE BENEFITS APPLICATIONS MARKETS

Cynergy Series Retrofit Kit

2 1/2. Applies to both UP & DOWN. Specify quantity. Requires 8" blank See integrated controls guide for more details.

RECESSED T-Bar & Drywall. Project. Type. Notes. 3 7/8" 98mm

RLK SERIES Retrofit Lamp Kit for LED Tubes

BEAM SPREAD NR = Narrow (36 degree) WD = Wide (56 degree) WW 2 = Wall Wash. REFLECTOR FINISH SD = Semi- Diffused

Cubic SurroundLite TM

LASER BLADE DOWNLIGHT - NEW CONSTRUCTION WITH HOUSING - INTEGRAL

LED Lumina USA s Green Initiative

ROUND SQUARE E DOLOGY.COM S P E C I F I C AT I O N S H E E T SPECIFICATION SHEET ROUND&SQUARE TRIM&TRIMLESS FIXED. Project name: Type:

CAVA CURVE LED PENDANT DIRECT/INDIRECT W W W. L U M E N W E R X. C O M

Everline LED Fixtures & Retrofit Kits

MUST HAVES. in Quality lighting trusted by sparkies all over the globe.

LED Flat Panel Luminaires

DESCRIPTION PROJECT: Via 2 features our Asymmetrical Lens Optic for smooth, comfortable

Regular LED Tri-proof Lights. Product size

Project. Type. Notes PRODUCT ID NOM.LUMENS/FT CRI COLOUR TEMP. SHIELDING LENGTH/FT FINISH

Voltage Driver Options UNV Universal voltage V V V V

G4 LED HID Retrofit. Standards Manual

LUMINAIRE ID DIRECT OPTICS INDIRECT OPTICS LIGHT SOURCE CRI DIRECT LUMEN PACKAGES. LED - high performance LED

VIA 2 LED PENDANT DIRECT/INDIRECT W W W. L U M E N W E R X. C O M

ALG LED Area Light K lm 21000lm 33000lm 100W 150W 300W. Type III Type V

Unparalleled quality compared to common LED floodlights. Proprietary optics for the highest lighting control precision,

LED LINEAR TUBE AFFORDABLE

Project. Type. Notes PRODUCT ID NOM.LUMENS/FT CRI COLOUR TEMP. SHIELDING LENGTH/FT FINISH VOLTAGE


Steve Sindoni Commercial Engineer OSRAM Sylvania

UNIVERSAL LIGHT 15-24W. IP64 WARRANTY

LED Panel Lights (DLC Premium)

LUMINAIRE ID SIZE CENTER OPTICS SIDE OPTICS LIGHT SOURCE CRI LUMEN PACKAGES COLOR TEMP. LED - high performance LED

GigaTera. LED Lighting LED LIGHTING CATALOG Commercial Lighting

PIX STICKS CIRRUS WITH POWER

LED Lighting. Cooperative Purchasing Connection LED Lighting Offering

THE MARKET S EASIEST FLUORESCENT-TO-LED CONVERSION

DESCRIPTION PROJECT: Vega is an efficient architectural LED troffer with a distinctive luminous shielding that features a median textured

62.6g / 0.13lbs. RoHS Compliant Dry and Damp Location IC Over Temperature Control

23W Dimmable LED Bulb - 4' T8 Lamp Lumens - Double Ended- Replacement/Upgrade for Fluorescent

Transcription:

PROJECT NAME: PROJECT NOTES: LED SOLUTIONS, INC. www.jaykal.net 26832 Lewes Georgetown Hwy, Building 2, Unit E Harbeson, DE 19951 (P) 302-295-0015 (F) 302-295-0016 DESCRIPTION: The simple design of the Retrofit Kit delivers maximum light distribution and is ideal for commercial and industrial troffer retrofit applications. The kit is engineered as a highly energy efficient and eco-friendly retrofit, delivering 139lm/W. By utilizing state of the art rare earth magnets, Jaykal was able optimize the heat transfer characteristics for the life of the fixture. FEATURES & BENEFITS: Wattage Options: 10W, 16W, 20W, 24W,30W, 36W, 40W, 45W, 55W, 60W or Multi-Wattage Drivers CCT Options: 3000K, 3500K, 4000K, 5000K 139+lm/W with PC Cover Option Optional: 0-10V Dimming, Polycarbonate Cover, Emergency Backup, Integrated Controls 5 Year Warranty 5 YEAR STANDARD WARRANTY EXTENDED WARRANTIES AVAILABLE

SPECIFICATIONS TABLE Model 10W 12W 16W 20W 24W 30W 36W 40W 45W 55W 60W Input Voltage 100-277VAC 50/60hz Wattage 10W 12W 16W 20W 24W 30W 36W 40W 45W 55W 60W Efficacy 139+lm/W with PC Cover Option Lumens 1,390lm 1668lm 2,224lm 2,780lm 3,336lm 4,249lm 5,004lm 5,560lm 6,255lm 7,645 8,340lm Power Factor >0.9 THD <15% CRI >80 L70 Hours CCT 75,000 Hours+ 3000K/3500/4000K/5000K Operational Temp. -30 C 50 C Housing Material Aluminum ORDERING GUIDE MODEL - WATTAGE - LENGTH - CCT - OPTIONS - LIGHT BARS SENSORS JLS68102-MGT 10 = 10W 1 = 1 FT. 30K = 3000K EM = Emergency Backup 1 = One Bar OC = Occupancy 12 = 12W 16 = 16W 20 = 20W 24 = 24W 30 = 30W 36 = 36W 2 = 2 FT. 3 = 3 FT. 4 = 4 FT. 35K = 3500K 40K = 4000K 50K = 5000K 10 = 0-10V Dimming P = Phase Dimming PC = Polycarbonate Cover 50 = 50-50 Driver M1 = (12W/16W/20W/24W) M2 = (18W/24W/30W/36W) M3 = (36W/40W/48W/60W) 2 = Two Bars 3 = Three Bars 4 = Four Bars *4ft. Bars Max 24W per bar. *3ft. Bars Max 20W per bar. OCBL = Occupancy Bi-Level Dimming, One-Key Commissioning OCAL = Occupancy with Bi-Level Dimming, Wireless Grouping, One-Key Commissioning BLANK = No Sensor See Page 3 for Control Features 40 = 40W *2ft. Bars Max 13.4W per bar. 45 = 45W *1ft. Bars Max 6.7W per bar. 55 = 55W 60 = 60W

CONTROL OPTIONS: Option OC: ON/OFF Occupancy Sensing High Frequency Motion Sensor Hidden Installation Behind Diffuser Option OCBL: Occupancy Sensor with Bi-Level Dimming & One Key Commissioning Task Lighting/ Lumen Maintenance Daylight Harvesting High Frequency Motion Sensing One-Key Commissioning - Save the settings for the fixture and program each additional fixture with One-Key Press. Hidden Installation with LED/Daylight Spectrum Recognition Option OCAL: Occupancy Sensor with Bi-Level Dimming, Grouping and One-Key Commissioning Task Lighting/ Lumen Maintenance Daylight Harvesting High Frequency Motion Sensing One-Key Commissioning with Wireless Remote Hidden Installation with LED/Daylight Spectrum Recognition One-Key Commissioning - Save the settings for the fixture and program each additional fixture with One-Key Press. RF Wireless Grouping of up to 30 Fixtures.

Installation Guide for 2 and 4 Ft. MGT Kits 1. Disconnect AC power from the fixture 2. Begin by removing the existing lamps from the fixture. 3. Remove the ballast cover and set it aside, it will be reinstalled later. 4. Disconnect and remove the ballast and tombstone assemblies. 5. Install the LED driver in the location of the original ballast. The LED driver has a magnetic attachment to facilitate installation. One you have positioned the LED driver, install self tapping screws to secure the driver permanently in position. 6. Install the magnetic LED strips into the desired positions inside the fixture housing. The magnetic backing will hold the strips in place during installation. Remove the access covers from each end of the strips (See Fig1.) Install self tapping screws into the mounting holes to permanently position the strips. 7. Connect the LED driver and strips as illustrated for your application. (See Page 4 of this Document) 8. Reinstall the ballast cover which was removed in step 3, to protect the LED driver and wiring. 9. Reconnect fixture power and test for normal operation. Fig. 1

LED Bar Wiring Examples Configurations for 2 and 4 FT. Kits 2 or 4 ft. 1 Lamp Replacement 2 or 4 ft. 3 Lamp Replacement 2 or 4 ft. 2 Lamp Replacement 2 or 4 ft. 4 Lamp Replacement LED Bar Wiring Example Configurations for 6 and 8 FT. Kits 8 ft. 1 Lamp Replacement 6 ft. 2 Lamp Replacement 8 ft. 2 Lamp Replacement 6 ft. 2 Lamp Replacement