Typical applications are the control of barriers/booms in the parking and access control environments.

Similar documents
Single or Double 240VAC motor control for domestic and industrial gates and doors.

TEL: G&C Electronics CC E. T.

3.5 Amp Bi-polar stepper motor drive MSE570 Evo 2

CENTOR TRAFFIC BARRIER

The RPM module will remain in Normal mode by default. It will also return to this mode after settings have been recalled or changed


SALDET SALES & SERVICE, INC. CLINTON TOWNSHIP, MICHIGAN

MDC VAC, 15A Brushless Controller. User s Guide. 910 East Orangefair Lane, Anaheim, CA

MDC Series

CAPACITANCE LEVEL SWITCH

6900 Series PowerMatic. Low Energy Power Operator

PARQUBE FIRST LINE MAINTENANCE MANUAL

AA4006 Speed Sensitive Trip Unit. User Manual

Flight Systems. Replacement for KASSEC DESCRIPTION

Installation/Owner s Manual 1603

SECURITY DOOR CONTROLS

CB-9 CONTROL BOARD INSTRUCTION MANUAL

CB CONTROL BOARD INSTRUCTION MANUAL VERSION 1.03 DATE 30/10/2000

6900 Series PowerMatic Low Energy Power Operator

TABLE OF CONTENTS WARNINGS GENERAL INFORMATION INSTALLATION INSTRUCTIONS OPERATING INSTRUCTIONS ACCESSORY CONNECTIONS MOTOR CONTROL SCHEMATIC

Mclennan Servo Supplies Ltd. Bipolar Stepper Motor Translator User Handbook PM546

BE1-50/51B with S1 Case or FT-11 sized Case and Cover For non-retrofit applications, see Product Bulletin UHD.

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

MX431 Generator Automatic Voltage Regulator Operation Manual

Installation/Owner s Manual 1601 / 1602

Gate & Door Controller with LCD and Intelligent Technology

GLM SERIES CONTROL Users Manual Rev:

MCD Pump Application Module

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

Emergency lighting units EM powerled

CONTROL UNITS VEHICLE EXHAUST GASES. Pure advantages

ZAP MOTOR AND CONTROL UNIT INSTALLATION MANUAL

Emergency lighting units EM powerled

Emergency lighting units EM powerled

User Manual. 1. Introduction

Gilgen FD 20 swing door drive unit

ELSEMA 240VAC Slider Control Board, SLD

Temperature Controllers

CAPACITIVE LEVEL SWITCHES. Capacitive switch catalogue HYC-CSC01 Elect. Iss. 01

91 (2311 mm) (1581mm) (1375 mm)

DIGITAL NET. MULTI-BEAM OPTICAL BARRIER OPTICAL OR BY WIRE SYNCHRONISM COMPLETE DIGITAL CONTROL with AGC 10 1 METRE 2 STRAIGHT OR 4 CROSSED BEAMS

Temperature Controllers

SECTION MOTOR CONTROL

Intelli-Park Series Barrier Arms. Intelli-Park 9. Intelli-Park 14. Intelli-Park 18. Intelli-Park 32

Kentaur Road Barriers

Installation/Owner s Manual 1601 / 1602

Fincor Series 2230 MKII/2240

Local Control Network - building controls in perfection

Procurement Specification for a High Security Lift Arm Barrier (HSLAB) EB950 CR Armstrong High Security Lift Arm Barrier

CX-EMF-2 MULTI-FUNCTION RELAY

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

01 Spectra Plus - Introduction

OPERATING INSTRUCTION: DGC-6D/6D1I

ELSEMA Single / Double Gate Controller, for 12V / 24V Motor, GATCO12S, GATCO24S, GATCO12D, GATCO24D

EC DECLARATION OF CONFORMITY

MODEL 422 Submersible Pump Controller

T: +44 (0) F: +44 (0) E:

CD100 Series. Operators Manual SINGLE COLUMN CARD DISPENSER

CONTROL UNIT BIOS2. Manual for installation. Programmable Control board for wings gates.

Parking Gate INSTALLATION AND OPERATION MANUAL

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

ENGEN -100/ENGEN -200 ENGINE GENERATOR CONTROLLER

Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2

Deep Insert Skimming TMD Security Card Protection Plate (CPP) Tom Moore MD North America TMD Security

DNH INDUSTRIES ***** COMPACT ***** EASY TO INSTALL ***** STATUS INDICATORS ***** DUAL LINE FUSING ***** INSULATED FRONT COVER ***** ADJUSTABLE OUTPUT

ECM-MSPD. Installation, Operation, and Maintenance Manual

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI

Operation and Installation Manual

Operating Instructions Pedestrian Turnstile Type MPT 33

Contact Details: Mail Id:

2904 Power Supply Installation Instructions I-EA00041

90XL PINSPOTTER CONTROL CHASSIS

Installation/Owner s Manual 1601 / 1602

The information in this chapter will enable you to: 90VAC to 50/60 Hz

PKG-341-MBC08-PS-CBL System Diagram and Specifications

LOCKNETICS Power Supplies. 510 Series Power Supply Controller 12 and 24 VDC. 505 Series Power Supply. 505DE Series Delayed Egress Controller

ADDITIONAL INFORMATION. BE1-50/51B SELF POWERED TIME OVERCURRENT RELAY and RETROFIT KITS. FEATURES and APPLICATION Page 2

CONTROL, PROTECTION AND VISUALIZATION ELECTRONIC MANUAL CEN- TRALITE FOR GENERATING SETS CMD2.0

SST-3 Start-Stop-Throttle

ELSEMA Single / Double Gate Controller, with Battery Charger, for 12V / 24V Motor, Enclosed, GATCOxxxCH

Operating Instructions Type MPT 53

POWR-GARD Relay Testing Equipment PGT-0400 Series Ground-Fault Relay Test Unit PGT Ground-Fault Relay Test Unit

CBM-105FN/FP Circuit Board

OPERATING INSTRUCTIONS MCP-MT1

BLD75-1. Bilevel Step Motor Driver. User s Guide. 910 East Orangefair Lane, Anaheim, CA

Functions provided by measuring relays in railway equipment

Parker AC10 Frequency Inverter (to 22kW) Easy Start Guide

Starting System DS-102 Series 200. Elmatik AS P.O.Box 309 NO-3471, Slemmestad T F

BVF300 'Special' Battery Voltage Monitor

REXON TURNSTILE. Security without compromising

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

BLHV, BLHV-1. High Voltage Step Motor Driver. User s Guide. (714) fax: (714) website:

PowerMaster MODEL MBG. Installation Manual U L R UL 325 AND UL 991 LISTED MEDIUM DUTY BARRIER GATE OPERATOR TABLE OF CONTENTS

MODEL D-SBG Single Arm Barrier Gate Operator

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

GL1200T Cut & Seal. (GL1200 Seal only)

BLDPN30001 Series. 30A Brushless DC Controller. User s Guide E. Landon Drive Anaheim, CA

Emergency lighting units EM powerled

MULTI FUNCTIONAL COUNT CHECKER MODEL Poka Patrol CNA-4mk3

K001A6039. Control Board Replacement Kit WARNING INSTALLATION INSTRUCTIONS APPLICATION REQUIREMENTS: FUNCTION: REMOVE EXISTING BOARD

Transcription:

Barrier Logic Model - BL110B The BL110B is a barrier logic unit which has been developed to control barriers using magnetic motors with ease of installation. The BL110B accepts inputs from card readers and cash registers as well as an input from a loop detector for safety and closing. Applications Typical applications are the control of barriers/booms in the parking and access control environments. Features - Logic Selectable Memory/Non Memory input. The Memory input feature will allow opening inputs to be memorized. This will then enable a number of vehicles to pass over the closing loop before the barrier lower output is enabled. The purpose of this feature is to enable vehicles to pass the barrier without opening and closing for each vehicle and hence allowing rapid entry or exit of vehicles. Automatic/Manual mode. This mode allows the barrier to be manually operated for maintenance purposes using the toggle switch mounted on front of the unit. Barrier raise/lower relay output. This output is used to control the motor which raises or lowers the barrier. The motor can be connected directly to this relay without the need for an external relay. Ticket vend interlock output. This output is used to prevent tickets from being issued when the barrier is in the raised position. Time out if vehicle reverses out. (Auto Close) On some occasions a vehicle may raise the barrier and then reverse out. In this situation the logic will time-out (switch selectable) and automatically lower the barrier. Roll-back protection. After a vehicle has passed the closing loop and the barrier is closing, it is possible for the vehicle to roll backwards under the closing barrier. In this situation the logic will raise the barrier again until the vehicle moves forward off the closing loop. 1

Toggle input. The barrier can be raised and lowered from a remote pushbutton or radio receiver contact by using the toggle input. Dip switch used to enable or disable auto close. Facility for extra loop detector for opening input interlock. An arming loop detector may be used to prevent the barrier from being raised when there is no vehicle present at the ticket issuing machine. This is done by placing a loop in front of the barrier and a vehicle must be present on this loop to allow opening of the barrier. Facility for Free Exit loop detector. Another loop detector may be placed after the barrier and used to raise the barrier as a free exit option. This feature is normally used in a bi-directional lane. Detector/Beam Off Delay. This feature enables a beam delay of 0, 5, 10 or 15seconds. When enabled, the beam is extended to prevent false closing of the barrier. Indicators Power Indicator. This LED Indicator illuminates when power is present. Barrier Raise Indicator. This LED Indicator is illuminated when the barrier output relay is switched on to raise the barrier. Barrier Lower Indicator. This LED Indicator is illuminated when the barrier output relay is switched off to lower the barrier. Technical Specifications Power supply Input Toggle Input Detector / Beam Input Raise/Lower Output Relay Output Relay Indicators Protection Connector Dimensions Operating Temperature Storage Temperature 200-260VAC 50Hz 1.5VA collector NPN transistor output. This input is isolated from the logic. When held on, the barrier will stay in the open position. collector NPN transistor output. This input is isolated from the logic. collector NPN transistor output. This input is isolated from the logic and is used to close the barrier when a vehicle has passed through the barrier. When Dip SW 2 and are used, this input has a selectable off delay of 0 to 15sec in 5 second increments. These outputs are a relay contact rated at 5A/220VAC. This output is a normally closed relay output rated at 0.5A/5VDC. LED indicators show: Power, Barrier Raised and Barrier Lower. Loop isolation transformer with zener diodes and gas discharge tube. 11 Pin Connector on rear of unit. 80mm (height) X 0mm (width) X mm (Depth excl. connector). -0 C to +80 C -0 C to +85 C 2

Switch Settings BL110B Switch Settings Switch No. Function ON OFF 10 Reset (normally in Off position) On Off Not Used - Off 8 Not Used - Off MI/NMI input select MI NMI 6 Roll back time 5 Sec 2 Sec 5 Auto Close time None 20 Sec Toggle input select On Off 2, Beam Off Delay 0 Seconds - S2/S 2, Beam Off Delay 5 Seconds S S2 2, Beam Off Delay 10 Seconds S2 S 2, Beam Off Delay 15 Seconds S2/S - 1 Not Used - Off Installing Snubber Network Due to the high inductance of the barrier motor, it is highly recommended to install an external snubber network to reduce electrical noise and interference generated when switching the motor. Recommended snubber network and connection details are shown below.

Wiring Diagram Standard Configuration NEUTRAL MOTOR RAISE OUTPUT LOWER OUTPUT Remote 10 Toggle Input Detector or Beam 8 Detector/Beam Input LIVE 220VAC NEUTRAL 1 2 POWER Configuration with Arming Loop Detector LD100 Presence Relay Configuration with Free Exit Detector LD100 Pulse Relay

Contact Details Refer to our web site for distributor details. Email: proconel@proconel.com Web: www.proconel.com 5