Terminator DL-S for use with BSX *, HTSX, KSX self-regulating, HPT power-limiting, and FP constant watt heating cables

Similar documents
In-Line / T-Splice Kit Installation Instructions. Terminator DS-L for use with RSX, TSX, VSX self-regulating heating cables

Power Connection Kit Installation Instructions. Terminator DP-M for use with TEK and HTEK series constant watt heating cables

Terminator TM DL Lighted Power Connection/End Termination Kit INSTALLATION PROCEDURES. For Power Connection or End Termination Applications

Power Connection Kit Installation Instructions. Terminator ZP-M for use with TEK and HTEK series constant watt heating cables

Terminator. DP Power Connection Kit INSTALLATION PROCEDURES

Terminator DP/FAK-2 and FAK-2L. Elbow Splice Kit for Electrically Heated TubeTrace Bundles INSTALLATION PROCEDURES

PETK Power and End Termination Kit

PETK Power and End Termination Kit

Terminator DP/FAK-4LHT Kit for In-Line Splice of Electrically Heated TubeTrace Bundles INSTALLATION PROCEDURES

SCTK Splice Connection Termination Kit

SCTK INSTALLATION PROCEDURES. Splice Connection Termination Kit. SCTK-1 for BSX, RSX, VSX SCTK-2 for KSX, HTSX SCTK-3 for HPT, FP

TracePlus. VIL-6 End of Circuit Light Kit INSTALLATION PROCEDURES. VIL-6-H for BSX, HTSX, KSX, HPT, FP VIL-6-V for RSX, TSX, VSX

Terminator DP/FAK-5LHT Kit for Tee Splice of Electrically Heated TubeTrace Bundles INSTALLATION PROCEDURES

Terminator DP/FAK-5 and FAK-5L

ZP-XP Power Connection Kit. Terminator. The Heat Tracing Specialists INSTALLATION PROCEDURES

Terminator DP/FAK-4 and FAK-4L for In-Line Splice of Electrically Heated TubeTrace Bundles INSTALLATION PROCEDURES

PETK Power and End Termination Kit

TracePlus. PCA Power Connection Kit INSTALLATION PROCEDURES. PCA-H for BSX, HTSX, KSX, HPT, FP PCA-V for RSX, TSX, VSX

Terminator ZP/FAK-1 Kit Electrically Heated TubeTrace Bundles

Terminator ZP/FAK-4L Kit Electrically Heated TubeTrace Bundles

Terminator ZP/FAK-5 and 5L

FAK-7HTS High Temperature Tubing Bundle End Seal Kit INSTALLATION PROCEDURES

UPC Power Connection Kit

DEVI EasyConnect Heating Cable Connection System

Electric Heat Tracing INSTALLATION PROCEDURES

JBM-100-STB NEMA 4X-rated connection kit Installation Instructions

Electric Heat Tracing INSTALLATION PROCEDURES

C A Heating Cable Gland Kit Installation Instructions

DEF-Trac. Design and Installation Guide. August 2015

DEF-Trac. Design and Installation Guide. August 2014

JBS-100-A, A6 SINGLE ENTRY POWER CONNECTION WITH JUNCTION BOX INSTALLATION INSTRUCTIONS

JBS-100-STB Single Entry Power Connection with Junction Box Installation Instructions

Installation & Operation Instructions. Type USL Signal Light Kit for Self-Regulating Constant Wattage Heating Cables. Constant Wattage Grommet

TSRT TSRT Tee Splice Kit Installation Instructions

ET-PWR-END-KIT Installation Instructions (part #JSR00)

SPC-P Smart Power Connection with Temperature Monitoring Transmitter Pipe Mounted Installation Instructions

PMKG-JS POLYMATRIX SPLICE CONNECTION KIT INSTALLATION INSTRUCTIONS

C A HEATING CABLE GLAND KIT INSTALLATION INSTRUCTIONS

C Power Connection Kit

Application Specification Circular Plastic Connector (CPC) Series 45 System 05 AUG 14 Rev D

PMKG-J2LP PolyMatrix Powered Splice Kit Installation Instructions

Power Connection Kit installation instructions

Self-Regulating Freeze Protection Heating Cable

AutoMatrix Power Connection Kit. (1) This type 4X enclosure is intended for indoor or outdoor use primarily to. (2) May be required (see step 1).

EMK-XP ElectroMelt Power Connection and End Seal Kit Installation Instructions

SERGE BARIL HA-S HAZARDOUS AREA SEAL KIT

Heating Cable. Description

Products and Accessories. Information Guide

TubeTrace Tubing Bundles

HTP PTP/ PTJ Power Connection Kit for Pipes

SRK02 Hard Wire Power Connection Kit. Installation, Operation and Maintenance Instructions

CONTENTS. This Product is Certified by CANADIAN STANDARDS ASSOCIATION and Bears the Mark:

Assembly Instruction EL OCHITO WHITE CONTACTS 1000BASE-T/10GBASE-T TYPE I: PIN /SKT CABLE: S/FTP

UES-LL End Termination Kit

RT FlexiPanel TM Tank and Vessel Heating Panel

FLX TM Self-Regulating Winterization/Freeze Protection INSTALLATION PROCEDURES

Heating Cable. Description

8-Position Cat5E EMT Shielded Slim-Line Modular Plug

NAMSR SELF-REGULATING FREEZE PROTECTION HEATING CABLE SELECTION

WarmlyYours ET-SR Series Heating Cable Installation Manual for Roof & Gutter Deicing

Installation Instructions

Shock/Vibration Control Switches Installation Instructions Models: VS2, VS2C, VS2EX, VS2EXR, VS2EXRB and VS94 GENERAL INFORMATION LISTED*

Heating Cable. Description

Splicing Procedures 4. 2 Insert the new wire between the parted strands. If more than one wire is being spliced, wrap them in opposite directions. Use

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Position Cat6 Shielded. Modular Plug Connectors. Application Specification

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Type HLT Self-Regulating Heater Cable For use in Ordinary and Hazardous (Classified) Locations

Network Zone System Part Numbers: Z23N-***** Z23R-****

PRO-Tect Pipe Freeze Protection Self-Regulating Heating Cable Install Manual (PT-Series)

INSTALLATION INSTRUCTIONS

Installation Instructions: ACCENT SYSTEM

3M Cold Shrink Silicone Rubber Termination QT-III 7600-S-3G Series Three-Core Outdoor Termination

INSTALLATION INSTRUCTIONS

WarmTrace TM HSX Hot Water Temperature Maintenance INSTALLATION PROCEDURES

SYSTIMAX GS3 and 1100GS6 Evolve Modular Panel Instructions

Assembly Instruction. EL OCHITO BLUE CONTACTS SuperSpeed USB TYPE I: PIN /SKT CABLE:

3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

INSTALLATION GUIDES DekaFlex Connectors DEKAFLEX MC-HL CONNECTOR INSTALLATION GUIDE FOR HAZARDOUS LOCATIONS

Shock/Vibration Control Switches

Pole Mount COD Installations (PMCOD)

SLiC Aerial Terminal and Spiral End Seal for use with AMP* Quiet Front Terminal Blocks

Nuheat WEATHER-READY HEAT TRACE PIPE FREEZE PROTECTION SYSTEM. Self-Regulating Heating Cable Installation Guide. UV Resistant Polyolefin Outer Jacket

Installation Instructions: ACCENT HIGH OUTPUT SYSTEM

Z22C-** Preconfigured Network Zone System

Type LT Self-Regulating Heater Cable For use in Ordinary and Hazardous (Classified) Locations

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION.

PATCHMAX GS3, GS6 and PowerSUM Modular Panels

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

Installation Instructions: Read these instructions in its entirety before performing any installation work.

Installation Instructions CONSTANT WATT (CW) AND SELF-REGULATING (SR) PIPE TRACING CABLES

C15C C15C. Page 1 of 20

Type LT Self-Regulating Heater Cable For use in Ordinary (Unclassified) and Hazardous (Classified) Locations

INSTALLATION INSTRUCTIONS

SynergEX Panelboards for Hazardous Locations

Heating Cable. Cut to Length in Field. Description

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

NAMSR SELF-REGULATING CABLE FOR PIPE FREEZE PROTECTION / SPECIFICATION SHEET WSC-0930

Universal Network Zone System Part Numbers: Z23U-****

Transcription:

Lighted Power Connection / Lighted End Termination Kit Installation Instructions Terminator DL-L for use with RSX, TSX, VSX self-regulating heating cables Terminator DL-S for use with BSX *, HTSX, KSX self-regulating, HPT power-limiting, and FP constant watt heating cables For Power Connection (1 Cable - Standard, 2 Cables - w/ Optional Boot) or End Termination (1 Cable) Applications * BSX self-regulating heating cables may also be used with Terminator DL-L

Kit Contents 1 2 Item Qty Description 1 1 Expediter Assembly Support Cap w/ O-ring Threaded Grommet Compressor Grommet Support Base w/ O-ring 2 2 1 Junction Box Lid 3 1 Junction Box Base w/ O-ring 4 1 Nut 1 5 1 Banding 6 1 RTV Tube 7 1 Power Connection Boot 3 8 1 Banding Guide 9 1 Lamp Terminal Blocks w/ DIN Rail (Refer to terminal specifications for maximum allowable wire size) 10 1 Junction Box Cord 11 1 Optional Power Connection Boot - for 2 cable power connection installations - not provided in kit 4 5 Tools Required 6 7 8 9 Certifications/Approvals IP66 NEMA/Type 4X -60 C Ta +55 C Ordinary & Hazardous Locations Class I, Division 2, Groups A, B, C, & D, Zone 2 IIC Class II, Division 2, Groups F & G, Class III Listed Heat Tracing Cable System 137M 10 Warnings Due to the risk of electrical shock, arcing and fire caused by product damage or improper usage, installation or maintenance, a ground-fault protection device is required. Installation must comply with Thermon requirements and be installed in accordance with the NEC, CEC, or any other applicable national and local codes. Component approvals and performance ratings are based on the use of Thermon specified parts only. User supplied power connection fittings must be UL Listed or certified for intended use. De-energize all power sources before opening enclosure. Keep ends of heating cable and kit components dry before and during installation.

Installation Instructions 3 4 1. Locate bus connection (HPT and FP only) and cable as shown. Cut end of cable at angle to aid in piercing grommet. Leave additional cable for expansion loop. See page 9 for multiple cable installation tips. 4. Insert banding guide into expediter and snap into place. 2. Insert cable into expediter. If mounted on bottom of pipe, punch out weep hole. 5. Mount expediter to pipe using pipe band. Do not band over cable. 3. Slide expediter toward pipe and route cable through support base entry. 6. Cut off end of cable.

Installation Instructions 5 6 7. Terminate cable using cable termination (for BSX, HTSX, KSX, RSX, TSX, and VSX) on pages 11-14 or cable termination (for HPT and FP) on pages 15-18. 10. Mount junction box base on expediter. Make sure to align slots to properly orient junction box base. 8. Push excess cable back through expediter. Tighten cap securely. Tape cable expansion loop to pipe. 11. Install power connection fittings (user supplied) and pull in power and ground wires (if necessary). 9. Using dimple molded into side of junction box base to locate center of hole, drill for user supplied power connection fittings per manufacturer s recommendations (if necessary). 12. Install quick mount terminal blocks.

Installation Instructions 7 8 13. Complete system wiring. See page 20 for wiring details. 16. Lid latch mechanism fully engaged. To remove lid, repeat steps 14 and 15 but in the opposite direction. 14. Install junction box lid and twist hand tight. Insert screwdriver into ratchet slots located on side of junction box base. 15. Use screwdriver to ratchet on junction box lid. Lid will rotate 30 degrees.

Two Cable Layout Tips 9 10 A1. Locate bus connection (HPT and FP only) and cable as shown. Cut end of cable at angle to aid in piercing grommet. Leave additional cable for expansion loop. A2. Insert two cables into expediter.

Cable Termination (for BSX, HTSX, KSX, RSX, TSX, VSX) 11 12 B1. Cut and remove overjacket. Do not cut metallic braid. B4. Cut and remove primary insulation jacket. Omit this step for KSX, HTSX, and VSX cables. B2. Separate braid strands at edge of overjacket and pull cable through opening in braid. B5. Skive outside edges of black matrix. Do not cut bus wire strands. See page 19 for TSX cable matrix removal tips. B3. Twist braid into a pigtail. Trim ends of braid. B6. Cut V-notch in matrix and pull bus wires from matrix.

Cable Termination (for BSX, HTSX, KSX, RSX, TSX, VSX) 13 Cable Take-off (for BSX, HTSX, KSX, RSX, TSX, VSX) 14 B7. Cut and remove remaining center core of matrix. B8. Apply a liberal amount of RTV sealant to cable. B9. Slide boot onto the end of the cable.

Cable Termination (for HPT, FP) 15 16 C1. Cut and remove overjacket. Do not cut metallic braid. C4. Cut and remove fiberglass braid. Omit this step for FP cable. C2. Separate braid strands at edge of overjacket and pull cable through opening in braid. Twist braid into a pigtail. Trim ends of braid. C5. Cut and remove heating element and fiberglass overlay (FP cable only). Push any remaining heating element wire under the primary insulation jacket. C3. Cut and remove primary insulation jacket. C6. Cut and remove pairing jacket. Do not cut bus wire insulation.

Cable Termination (for HPT, FP) 17 Cable Take-off (for HPT, FP) 18 C7. Remove insulation from ends of bus wires. C8. Apply a liberal amount of RTV sealant to cable. C9. Slide boot onto the end of the cable.

TSX Matrix Removal Tips 19 Wiring Details 20 When using 10mm 2 (#8 AWG) power supply wiring, additional terminal blocks will be required. D1. Cut matrix core between inside edges of conductors. Do not cut bus wire strands. E1. Power Connection (1 to 2 Cables) D2. Cut and remove remaining matrix core. E2. End Termination (1 Cable Only) D3. Strip off matrix material at end of conductors.

21 22

Thermon Manufacturing Company 100 Thermon Drive P.O. Box 609 San Marcos, Texas 78667-0609 Phone: (512) 396-5801 Fax: (512) 396-3627 1-800-820-HEAT www.thermon.com Form No. 50809 (04/28/05)