INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Similar documents
INSTALLATION, OPERATION AND MAINTENANCE MANUAL

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Low Pressure Fluid Filters

DFA Series. Rainwater/Graywater Filtration Systems. Installation, Operation and Maintenance Manual DFM-2F-180 DFM-3F-180 DFM-3F-350

ECONOMAIR SERIES CYLINDERS

3M Housings CH Series

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

MetroPrime 22MPC Self-Priming Centrifugal Pump

Manufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1

Dual/Triple Manifold Water Filtration Systems Instruction Manual

DeZURIK 2 20" BOS BUTTERFLY VALVES

TITAN FLOW CONTROL, INC.

Operating and Installation Instructions

STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications

SUPPLEMENTAL MANUAL FOR THE INSTALLATION, OPERATION AND MAINTENANCE OF THE XL234 FILTER VESSEL

Spray Nozzle Adapters

RSV16 Retro-Fit Cartridge Acorn Controls SV16 Valve Cartridge

Colt Series C400, C500

Dual Flow Manifold Systems Instruction Manual

TITAN FLOW CONTROL, INC.

Lubricator Gun: 10,000 psi (700 bar) Maximum Delivery Pressure when disconnected from Dispenser

PFS Rotameter. Variable Area Flowmeter. Instruction Manual PFS-RM200, RM230, RM250

Scale Feeder Manifold Water Filtration System Instruction Manual

Nilfisk-CFM SS Vapor Vacuum Instructions for Use and Spare Parts Manual

Model P-40 & Model P-25 POWER PUSHER

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

USER MANUAL. NEMA 48C Flange Mounted, Enclosed, Clutch Brake. FMCBE Model 500 FORM NO. L A (i)

APCO SRG-6500 SURGE RELIEF GLOBE VALVES

DeZURIK 24 and Larger BHP High Performance Butterfly Valves WITH (FB) FYRE-BLOCK SEAT

Sample Pro 3/4" Portable MicroPurge Pump. User's Guide P/N REV The World Leader in Air Powered Pumps

Pneumatic Cylinder 14 Bore X 21 Stroke Part No. P Replaces Part No. P

CLIF MOCK TM. Model 5030 Orifice Fitting. User Manual. Manual No , Rev. B

MODEL 200 MULTI-JET FLOW METER

AVK SERIES 41 SWING CHECK VALVE FIELD MAINTENANCE AND INSTRUCTION MANUAL FOR SWING CHECK VALVES 3" - 12"

Model AS-RC3260 TV Cart. Rolling Cart for Audio Mount System & Flat Panel TVs

APCO CVS-6000 CONVERTIBLE SWING CHECK VALVES

OWNER S MANUAL Z SERIES TRACKS. Rev. 355_05

Instruction Sheet SRSR SERIES. Rotating Sliding Rail System

Installation Instructions SRC Over-Size Tire Carrier Jeep Wrangler/Unlimited Part # 2743

Installation Instructions Receiver Rack (Part # 7700) Universal Application

OWNER S MANUAL. LOEGERING th Street SE Casselton, ND USA Fax:

DODGE CUMMINS Arctic-Heat Grid Relocation Kit

3 Station Bike Rack Organization Center

Pro Shot Grease Dispense Valve

FOR TECHNICAL ASSISTANCE

PARTS AND INSTALLATION MANUAL

Pneumatic Cylinder 14 Bore X 22 Stroke Part No. R (Formerly P )

Installation and Maintenance Manual

L DODGE CUMMINS MK-2 + BLK APPS Mount

MODEL 200 MULTI-JET FLOW METER

Model FM2642 Wall Mount. Full Motion Television Wall Mount

GA Industries, LLC 9025 Marshall Road Cranberry Township, PA USA Telephone (724) Fax (724)

Tiller Lock Assembly

DODGE CUMMINS Air-Boss CR Intake Plenum

FOLD N STORE. Table Tennis Table. Assembly Instructions Model , DS, DS CONTACT INFO Hours.

GRINNELL Model B302 and Model BN302 Grooved End Butterfly Valves with Gear Operators or Lever-Lock Operators General Description

Nor East. Instructions Safety Messages. Inspection. Parts. DeZURIK Service. Type 05 Pneumatic Actuator Used With Globe Valves


Model E600 Tarping System

Dual Port Manifold Water Filtration Systems Instruction Manual

1 2-Inch Station Outlet Valves

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-122 REV A 12/09

Model AS-FM64 Wall Mount. Full Motion Television Wall Mount

LBH / LBFR SERIES. Instruction Sheet. Telescoping Lacer Bar

Instruction Sheet DWRSR-ZL. Zero Clearance Latch

Service Guide JATCO Environmental Protection Tank Model J-7000

AVK SERIES 41 SWING CHECK VALVE FIELD MAINTENANCE AND INSTRUCTION MANUAL FOR SWING CHECK VALVES 3" - 12"

Winslow Liquid Fuel Filters Standard Design Type 2 Service Instructions

Elgin Hydraulic Clutch-Brake ECB-240, Product Number FORM NO. L F FORM NO. L F-0704

Instruction Sheet. SFR Series. Swing Frame rack

Series 957, 957N, 957Z, 957RPDA, 957NRPDA, 957ZRPDA

Full Flow Drinking Water System Model: 3MFF100

Model T2642 Wall Mount. Television Wall Mount with Tilt Option

THIS IS A HIGH PERFORMANCE PRODUCT - USE AT YOUR OWN RISK!!!

DODGE CUMMINS 24V ISB OEM BYPASS LIFT PUMP KIT Installation Instructions Part #

7.3L Ford PowerStroke

WJ-Series. Turbine Meter Instructions ISO. 6 Meter. 3 Meter. Precision Flow Measurement. An ONICON Brand 9001:2008. if ie

MODEL 5120 Tire Repair Station

½ DODGE CUMMINS OEM BYPASS LIFT PUMP KIT Installation Instructions Part #

Spring-Engaged/Hydraulically-Released BD Caliper Brake. (i) MTY (81) QRO (442) MEX (55)

4000SS. For other repair kits and service parts, send for Ames Repair Parts Price List, PL-A-RP-BPD.

HARMSCO Hurricane Swing Bolt Water Filters Models: HUR 1X170FL, HUR 3X170FL HUR 5X170FL, & HUR 8X170FL

ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase

Air Curtain. Installation, Operating and Maintenance Instructions

Air Control Kit INSTRUCTIONS-PARTS LIST. Table of Contents HIGH VOLUME. 250 psi (1.7 MPa, 17.2 bar) Maximum Air Inlet Pressure

AIR CHAMP PRODUCTS. User Manual. Sheave & Pilot Mount Clutch-Brake Model BCB-275 FORM NO. L F-0414 FORM NO. L F-0414

Installation Instructions

Installation, Operation and Maintenance Manual

Hydraulic Transmission Jack, Telescopic

300 Series INSTRUCTION MANUAL. Compressed Air Filters Models 302 (grade) through 317 (grade)

Rosedale Model HSS300 and HSS750 Single Cartridge Housings for Liquids

Table of Contents. Page 2. midlandusa.com. Model PPG100

DeZURIK 24" THRU 36" RESILIENT BUTTERFLY VALVES

HV Gate Valve with pneumatic actuator

BC Brake Caliper. (i) MEX (55) QRO (442) MTY (81) DIST. AUTORIZADO

Models P420A-3100 & P420A-5100

Transcription:

PAGE: 1 of 8 INSTALLATION, OPERATION AND MAINTENANCE MANUAL ROSEDALE PRODUCTS, INC. MODEL 6 BAG/CARTRIDGE CONVERTIBLE 150/300 PSIG RATED FILTER UNIT Table of Contents I. Installation............................................................... 2 II. Operation................................................................ 4 III. Spare Parts List............................................................ 6 IV. Spare Parts Diagram........................................................ 7 Rosedale Engineering Standards are the property of A Rosedale standard or copy thereof shall not be distributed (except with express approval of Rosedale

PAGE: 2 of 8 I. Installation Please remove all shipping and crating materials carefully. Be sure to remove the plugs from the inlet and outlet openings. Dispose of all crating materials safely. The Model 6 Filter unit is capable of having several different piping variations based upon the outlet style of your unit. The inlet service line should be connected to the inlet flange or NPT coupling located near the top of the unit (above the basket level). The outlet service line should be connected to the outlet flange or coupling, located near the middle or bottom of the unit depending upon the style of your unit (below basket level). There are two 1/4" NPT ports on the shell and one 1/4" NPT port on the cover of the Model 6 Filter unit. These ports can remain plugged or used for pressure gauges or special fittings as your application requires. There are (2) 3/4" NPT ports near the bottom of the vessel. If you use the vessel as a bag/basket system, either port can be used as a clean port. If you use the vessel as a cartridge system, the top port is a dirty port, and the bottom port is your clean port Some installations require electrical grounding of all equipment, be sure to provide adequate grounding where necessary. After completing installation be sure to double check connections for integrity. Your Model 6 Filter unit has been factory pressure tested leak free, therefore, any seepage problems usually occur from improper installation connections. FOR BASKET AND BAG FILTER UNITS You are now ready to install the filter basket and bag (if applicable). Remove cover by loosening the cover eyenuts. The eyenuts in the slotted corners should be loosened sufficiently to swing free. Loosen the third eyenut sufficiently to allow the top cover and closure assembly to swing away from the top of the unit. If your application requires a basket seal, insert the basket seal under the basket flange. Refer to Figure 1 in the Spare Parts Diagram for installation position of your seal. Place the basket into the filter housing, make sure the basket flange is firmly seated into the basket collar. Insert bag into the bag basket making sure filter bag ring is firmly seated inside the basket flange. For best results, be sure filter bag is installed fully extended to the bottom of the basket. Before replacing cover assembly, inspect cover seal gasket (replacing as necessary). Close cover and alternately tighten the three clamp assemblies evenly to ensure a leak proof seal between the cover and housing ft-lbs body. Torque closure assemblies to a minimum of 60-90. Higher torque may be required depending on your application and filter condition. Rosedale Engineering Standards are the property of A Rosedale standard or copy thereof shall not be distributed (except with express approval of Rosedale

PAGE: 3 of 8 FOR CARTRIDGE FILTER UNITS You are now ready to install the filter cartridge units. Remove cover by loosening the cover eyenuts. The eyenuts in the slotted corners should be loosened sufficiently to swing free. Loosen the third eyenut sufficiently to allow the top cover and closure assembly to swing away from the top of the unit. The next step is to install the cartridge units. Cartridge guide posts are provided with your housing to allow the use of 10" sections of cartridge and to aid in the proper seating of the cartridge. Insert your cartridges on these guide posts. Install the spring retainer cups onto each cartridge to hold your cartridges firmly in place when the cover is closed to prevent liquid from passing by unfiltered. Before replacing cover assembly, inspect cover seal gasket (replacing as necessary). Close cover and alternately tighten the three clamp assemblies evenly to ensure a leak proof seal between the cover and housing ft-lbs body. Torque closure assemblies to a minimum of 60-90. Higher torque may be required depending on your application and filter condition. Your Rosedale Model 6 is now ready for operation! Rosedale Engineering Standards are the property of A Rosedale standard or copy thereof shall not be distributed (except with express approval of Rosedale

PAGE: 4 of 8 II. Operation Filter System Start-Up Procedure: Prior to turning on the flow to the inlet service, please make the following checks: 1. Check inside filter unit to be sure basket and filter bag (if applicable) or cartridge, are in housing and do not require cleaning or replacement. If necessary install a clean filter basket and bag or cartridges (if applicable). 2. Check that filter unit cover is securely fastened to housing. You are now ready to open the flow to the inlet service line. Slowly open the inlet service line approximately 25% of normal operational flow (open slowly as not to displace filter bag inside the housing). After filter unit is pressurized and vented, slowly open outlet service line unit valve until completely open. Complete opening of inlet service line until desired flow rate is reached. Once the desired service flow has been established, the filter will operate efficiently until dirty. However, under no circumstances should more than 15 PSI Differential Pressure through the filter be obtained. Operating the filter unit with a high differential may cause filter bags to rupture or cause cartridges to collapse resulting in damage to filter system and downstream equipment. To prevent excessive drop through the filter unit, regular inspection of the filter media is required. Monitoring of differential pressure through the housing can be utilized as a means of determining whether or not the filter media needs cleaning or replacement. When it becomes necessary to clean or replace filter media, follow the procedure outlined below: 1. First close the flow from the inlet service line. 2. Close the flow to the outlet service line. (In some applications closing flow to outlet is not required.) 3. Relieve the pressure from the filter unit. WARNING CONTENTS UNDER PRESSURE Relieve Pressure in accordance with Manufacturer s instructions before opening Filter Vessel. FAILURE TO DO SO MAY RESULT IN SERIOUS BODILY INJURY. 4. Drain housing sufficiently to access filter basket or cartridges. 5. Remove cover by loosening the cover eyenuts. The eyenuts in the slotted corners should be loosened sufficiently to swing free. Loosen the third eyenut sufficiently to allow the top cover and closure assembly to swing away from the top of the unit. Rosedale Engineering Standards are the property of A Rosedale standard or copy thereof shall not be distributed (except with express approval of Rosedale

PAGE: 5 of 8 6. Remove filter basket (or cartridges) and clean thoroughly, remove the filter bag (if applicable) and throw away. (Cleaning and reusing the filter bags or cartridges is not recommended.) 7. Remove debris and sludge from inside the inlet portion of housing to avoid interference with cover seal or flow of fluid being filtered. 8. Remove basket seal and inspect, replace if necessary. Clean basket seal groove and replace basket seal (see spare parts diagram for location of basket seal). 9. Install clean filter basket and filter bag (if applicable) or cartridges. Place the basket into the filter housing, make sure the basket flange is firmly seated into the basket collar. If applicable, insert bag into the bag basket making sure filter bag ring is firmly seated inside the basket flange. For best results, be sure filter bag is installed fully extended to the bottom of the basket. 10. Inspect cover gasket for cuts or other signs of failure and make sure it is properly seated. 11. Move cover back into position, and alternately tighten the three clamp assemblies evenly to ensure a leak proof seal between cover and housing body. Torque closure assemblies to a ft-lbs minimum of 60-90. Higher torque may be required depending on your application and filter condition. Your Rosedale Model 6 Filter unit is now ready for operation. Refer to filter system start-up procedure. Rosedale Engineering Standards are the property of A Rosedale standard or copy thereof shall not be distributed (except with express approval of Rosedale

PAGE: 6 of 8 III. Spare Parts List Your Rosedale Model 6 Filter unit will give you many years of reliable service provided periodic inspections are made of various components and replacement of worn parts are made promptly. The following is meant to be a recommended spare parts list, these parts are illustrated on the following page. SPARE PARTS LIST Balloon Description Part Number Time-Frame 1 Cover Seal 6150CG-* as needed 2 Basket Seal 6BG-* as needed 3 Cover 6*150 as needed 4 Eye Nut 6ENNI as needed 5 Rod End 6RENI as needed 6 Clevis Pin Assembly 6CPNI as needed 7 Filter Bag (See Order) as needed 8 Filter Basket (See Order) as needed 9 Filter Cartridge (See Order) as needed 10 Spring Cup Retainer C-5680 as needed 11 Guide Post 20" or 30" as needed 12 Tripod Legs 6T18*S as needed * Select Material Designation: C=Carbon Steel B=Buna N S=304 Stainless Steel E=Ethylene Propylene S304L=304L Stainless Steel V=Viton S316=316 Stainless Steel TEV=Teflon Encapsulated Viton S316L=316L Stainless Steel TSW=Teflon Solid White Rosedale Engineering Standards are the property of A Rosedale standard or copy thereof shall not be distributed (except with express approval of Rosedale

PAGE: 7 of 8 IV. Spare Parts Diagram Figure 1 Rosedale Engineering Standards are the property of A Rosedale standard or copy thereof shall not be distributed (except with express approval of Rosedale

PAGE: 8 of 8 Important Notice Warranty: In the event any filtration product is found to be defective in material, workmanship, or not in conformance with any express warranty for a specific purpose, Rosedale s only obligation and your exclusive remedy, shall be to repair, replace or refund the purchase price of such parts or products upon timely notification thereof and substantiation that the product has been stored, maintained and used in accordance with Rosedale s written instructions. EXCLUSIONS TO WARRANTY: THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR OTHER WARRANTY OF QUALITY, EXCEPT OF TITLE AND AGAINST PATENT INFRINGEMENT. LIMITATION OF LIABILITY: Except as provided above, Rosedale shall not be liable or responsible for any loss or damage, whether direct, indirect, incidental, special or consequential, arising out of sale, use or misuse of Rosedale filtration products, or the user s inability to use such products. THE REMEDIES SET FORTH HEREIN ARE EXCLUSIVE. 3730 West Liberty Road USA 734-665-8201 800-821-5373 Fax. 734-665-2214 filters@rosedaleproducts.com http://www.rosedaleproducts.com Rosedale Engineering Standards are the property of A Rosedale standard or copy thereof shall not be distributed (except with express approval of Rosedale