Maintenance Manual. Automated Fuel Maintenance System FTI-5A SINGLE TANK FUEL TECHNOLOGIES INTERNATIONAL

Similar documents
Maintenance Manual WITH ONE SUBMERSIBLE PUMP. Automated Fuel Maintenance System FTI-5A FUEL TECHNOLOGIES INTERNATIONAL LLC

Maintenance Manual. Automated. Fuel Maintenance System FTI-5A. FUEL TECHNOLOGIES INTERNATIONAL LLC

Maintenance Manual. Automated Fuel Maintenance System FUEL TECHNOLOGIES INTERNATIONAL

Installation and Maintenance Manual

Installation and Operations Manual

Installation Manual FTI-10A & FTI-20A SINGLE TANK. Automated Fuel Maintenance System FUEL TECHNOLOGIES INTERNATIONAL

Installation Manual. Automated Fuel Maintenance System FTI-5A FUEL TECHNOLOGIES INTERNATIONAL

Installation Manual. Automated Fuel. Maintenance. System FUEL TECHNOLOGIES INTERNATIONAL LLC

FPS-500. Fuel Polishing System Eliminates Microbial Contamination. Operating Manual

Operations Manual. Automated Fuel Maintenance System FUEL TECHNOLOGIES INTERNATIONAL

GENERAL SPECIFICATIONS FOR:

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

Read this entire manual before operation begins.

PRYCO, INC. P. O. BOX 108 Mechanicsburg, IL OPERATIONS AND MAINTENANCE MANUAL For PUMP SETS

660R-RAC Series. Gasoline Fuel Filter/Water Separators. Overview: Contact Information: Product Features: Instruction Part Number Rev F

HALLMARK INDUSTRIES INC

Marine Fuel Filtration. Marine FBO. Features:

MODEL 900 IMPELLER-TYPE FLOW METER

Users Manual Certified Series Direct Drive Pump 1-7 LPM

PPM EO-100 TM. Operation Manual

PARTS AND INSTALLATION MANUAL

Owner s Manual & Safety Instructions

Operating Instructions and Parts Manual Long Chassis Service Jacks

Installation, Operating and Maintenance Manual

75500MAX Series and 75500MAXM Series

FPS-500 / FPS 750. Fuel Polishing System. Installation and Operating Manual

25 GALLON PORTABLE OIL LIFT

320R-RAC Series. Gasoline Fuel Filter/Water Separators. Overview: Contact Information: Product Features: Instruction Part Number Rev.

IMPORTANT SAFETY INFORMATION

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

Pressurized Bead Filters

120RMAM Marine Series Fuel Filter/Water Separators

300 Series INSTRUCTION MANUAL. Compressed Air Filters Models 302 (grade) through 317 (grade)

BUG PREP KIT 2.0 HAND-PREP SYSTEM. User Manual REV A reva0616

KJ4000LW Operating Instructions & Parts Manual NSN

Updated: October 2012

FPS- 80. Manual. Reverso Pumps, Inc. Ph: (954)

SUBMERSIBLE MINI-PUMP

Electric Actuator Installation, Operation & Maintenance Manual

INSTRUCTION MANUAL INSTALLATION, OPERATION, AND MAINTENANCE ACTUATOR MANIFOLD

MODEL 200 MULTI-JET FLOW METER

Product Features: Removes 99% of free water. Available with 2, 10, or 30 micron Aquabloc II media

Series: PFUEG 1/12HP, 5000 RPM, 60 Hz Utility Pumps

# and # FAST Fuel System Kits

Scale Feeder Manifold Water Filtration System Instruction Manual

CRD610 Automatic Fitting Inserter

TALCO FIRE SYSTEMS. LSF Start-Up Instructions. 1) IMPORTANT: Inspect the unit for damage. Report any damage to the freight carrier immediately.

Owner s Manual & Safety Instructions

Model 1100 Turbine Flow Meter

STS GPM. Fuel Conditioning and Filtration System. Installation, Operating and Maintenance Manual

OWNER/OPERATOR MANUAL. Airmotor effective dia. in. 2.5

CRD600 Automatic Fitting Inserter

G8 Portable Fuel Transfer Pump Owner s Manual

Series 957, 957N, 957Z, 957RPDA, 957NRPDA, 957ZRPDA

"WHERE TUBING AND FITTINGS COME TOGETHER"

Getz Equipment Innovators 450 lb Portable / Wheeled Unit Dry Chemical Fill System Part No: 3G0061/3G0063

Colt Series C400, C500

SAVE FOR CONSUMER INSTALLATION / OWNER'S MANUAL. Single Handle Kitchen Faucet Model # LK2500. Important! You choose the flow rate!

Val-Matic Air / Oil Hydraulic Panel Pump Control System. Operation, Maintenance and Installation Manual

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

Operator s Safety and Service Manual

PENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS

Installation, Operation and Maintenance Manual

Dual/Triple Manifold Water Filtration Systems Instruction Manual

Kushlan Products, Inc. !IMPORTANT! Read Me First!

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

Spin Klin 3"-4" Apollo Angle

INSTALLATION AND OPERATING

MK Rittenhouse & Sons Ltd. 115 Litre/30 US Gallon Greenhouse Sprayer Manual

Trouble Shooting Guide EWA, 3-phase (D2422)

4" Spin Klin Twin Apollo Battery. Service & Maintenance Manual

#9040 FUEL TANK SWEEPER

Spin Klin 4" Apollo Twin

PATRIOT LIFT CO. ON-Lift Installation Guidelines

COOL DRAFT INSTRUCTIONS OWNER S MANUAL CONTENTS. Cool Draft MiniMister 14 Misting Fan CDMP1420BLU

DFA Series. Rainwater/Graywater Filtration Systems. Installation, Operation and Maintenance Manual DFM-2F-180 DFM-3F-180 DFM-3F-350

Read this entire manual before operation begins.

Table of Contents. Safety... 2 Specifications... 3 Setup Parts List and Diagram Warranty Operation Maintenance

Atlas PV-9WP Addendum

INSTALLATION INSTRUCTIONS, PARTS LIST AND CONFIGURATION GUIDE FOR THE CARBONATOR. Large Model No

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

Read this entire manual before operation begins.

ValveSentry USER S MANUAL REVISED 8/6/16 IMPORTANT! PLEASE READ CAREFULLY AND SAVE

SUNC3000 / Item #40885

FLEETWOOD TRAVEL TRAILER SLIDEOUT SYSTEM OWNER S MANUAL

Please begin by checking that you have received all of the parts that come with your kit.

4000SS. For other repair kits and service parts, send for Ames Repair Parts Price List, PL-A-RP-BPD.

Read this entire manual before operation begins.

AQUA2000 From O3PURE

Product Features. Easy installation. Pump adds only 3.3 to the overall assembly height. 60 GPH (227 LPH) flow rate while in priming mode.

Installation and Service Manual for SRC25, SRC252, SRC50, SRC502, SRC75, SRC752

ACF Operation Manual

Operating Instructions & Parts Manual. Oil Control Gun. Models 48UJ82, 48UJ83, 48UJ84, 48UJ85 and 48UJ86

Owner s Manual & Safety Instructions

IMPORTANT READ ME FIRST

Operator's Manual. Models (¾") (1") (1½ ) (2 ) (3") (4") (6") (8")

OPERATOR'S MANUAL W Series Premium Pallet Trucks

WARNING: Do not use pumps for gasoline or highly flammable products! Do not use pumps for water based fluids, solvents or chemicals!

VANGUARD A EZ INSTALL OPERATOR S MANUAL

Transcription:

Maintenance Manual Automated Fuel Maintenance System FTI-5A SINGLE TANK FUEL TECHNOLOGIES INTERNATIONAL 05/01/2016 Rev A Fuel Technologies FTI-5A Single Tank

Maintenance Section FTI - Fuel Maintenance Systems Contents General Maintenance Note s..... Page 3 Identifying Parts FTI-5A Single Tank...Page 3 Identifying Maintenance and Replacement Parts FTI-5A Single Tank......Page 4 Gauge Layout.............Page 5 Changing Filters 1-Micron Filter.......... Page 6 3 Micron, 10 Micron, Strainer Filters.........Page 7 Draining Water Separator.......... Page 8 Cleaning Water Level Sensor.....Page 9 Replacement Filters List...Page 10 Troubleshooting Guide....Page 11 Warranty.........Page 12 2

GENERAL MAINTENANCE NOTES Periodically routine maintenance will need to be performed such as changing filters and draining the water separator. When filters become full, the display will indicate the specific filter that requires changing. (Refer to alarm message descriptions in the Operations Manual) For best performance, it is recommended that you change the filters at least every six (6) months. A periodic check of the FTI System gauges will assist you in predicting which filters to have on hand before they become clogged. (See Gauge Layout section for a description of gauge operations). It is always a good idea to have spare filters on hand at all times, especially in the early stages of operation. New fuel and existing fuel can have water and particulate in it. Changing weather conditions can also affect your fuel condition. IMPORTANT: Do not attempt any maintenance operation until the system is turned off. Switch the system to Manual Mode Off first, to avoid mishaps or leaking fuel. After maintenance, you may return the system to Auto Mode. IDENTIFYING PARTS The following diagram points out the major components of the FTI System. The example shown is an FTI-5A Single Tank system Although your model or custom unit may vary slightly in location of the parts shown, the diagram is representative of the parts you will need to identify. Model FTI-5A Single Tank 1. Supply Line Connection: 1.0 NPT 2. Pump Priming Tee 3. Strainer 100 Mesh, 149 Micron Element 4. 10 Micron Pre Filter, Spin on 5. 3 Micron Pre Filter, Spin on 6. 1 Micron & Water Separator element 7. Site Glass 8. Return Line Connection: 1.0 NPT 9. Switch Gauge Panel 10. Control Panel (UL Listed) 11. Leak Detector 12. Pump / Motor 13. Serial No., Model No., FM Approved Tag. 3

IDENTIFYING MAINTENANCE & REPLACEMENT PARTS The following diagram points out the replaceable parts on your FTI system. The example shown below is for the model FTI-5A Single Tank. Although your model or custom unit may vary slightly in location of the parts shown, the included diagram is representative of the locations of the parts you will need to service or replace from time to time. Maintenance & Replacement Parts 1. Strainer Spin on Element 2. 5 GPM Pump 3. 1/2 HP Motor 4. Leak Detector 5. Water Sensor Model Shown: FTI-5A Single Tank 6. 10 Micron Pre Filter Spin on Element 7. 3 Micron Pre Filter Spin on Element 8. Water Separator and 1 Micron Particulate Replaceable Element 9. Site Glass 4

FTI GAUGE LAYOUT Below is a Diagram of the Switch Gauges on your FTI System. Each switch gauge monitors the filter identified in the above diagram and offers an ongoing visual status of system pressure, vacuum and each of the filters condition. Strainer (Vacuum) - Monitors 100 mesh strainer. (Alarm Trips @ 16-18 In.hg. & Pump turns off) System Pressure - Monitors system pressure. Measurement will vary due to restrictions of filters and length of pipe back to tank. (45 PSI High Set Point with Alarm & Shut off) (1-3 PSI Low Set Point to Monitor Flow with Alarm & Shut off) 10 Micron Filter - Monitors 10-micron filter. (Alarm Trips @ 16-18 DP & Pump turns off ) 3 Micron Filter - Monitors 3-micron filter. (Alarm Trips @16-18 DP & Pump turns off ) 1 Micron Filter - Monitors 1-micron filter. (Alarm Trips @ 16-18 DP & Pump turns off ) As the needle nears the contact point of the switch gauges, it indicates the filters are almost full. A check of the gauges can help you determine when to check your supply of filters before they require changing. When service is required, the unit will turn off, sound an audible alarm, and display the appropriate alarm message description on the controller screen. Refer to the Alarm message descriptions in the Operations Manual for the required maintenance 5

Changing the 1 Micron Filter / Water Separator FOUR BOLTS TO REMOVE BOTTOM HOUSING FILTER ELEMENT INSIDE HOUSING DRAIN VALVE 1. Turn off system. Put in manual mode. 2. Close inlet and outlet ball valves 3. Remove ground wire at bottom of filter housing 4. Open air vent valve on the filter head. 5. Drain filter housing at Drain Valve on bottom. 6. Loosen four collar bolts. 7. Rotate & remove housing with filter element. 8. Inspect filter housing, clean if dirty. 9. Remove the head gasket (O-ring). 10. Lubricate and install new gasket. 11. Replace Element with new one. 12. Repeat above steps to close filter housing. 13. Tighten all collar bolts to 100 in lbs. 14. Turn on system and check for leaks. 15. Return system to Auto Mode to run programmed schedule. 6

CHANGING 3 MICRON, 10 MICRON AND STRAINER Note: If the filter cannot be sufficiently tightened by hand, use a filter wrench (available at most auto supply stores). 1. To remove filter, put in manual mode. 2. Close inlet and outlet ball valves 3. Drain fuel at Racor Separator filter assembly. 4. Turn filter counter clockwise. 1. To reinstall new filter, lightly coat seal on filter with fuel. Install by turning clockwise to Apx. ½ to ¾ turn past point of contact. Turn system on and check for leaks. 7

DRAINING WATER SEPARATOR 1. Turn off system. Put in manual mode. 2. Close inlet and outlet ball valves. 3. Attach drain hose to bottom drain valve on filter housing. 4. Open top air vent valve on front of filter head. 5. Open ball valve on bottom of filter housing. 6. Drain water 7. Reverse above steps and run system. 8. Check for leaks. 9. Return system to Auto Mode to run programmed schedule. Note: It is recommended that you periodically drain water separator (even if not yet full) to remove any contaminates collected in bowl, and to reduce the possibility of clogging the petcock and or water sensor. 8

WATER SENSOR ALARM (Alarm Will Not Shut Off After Draining) If, after draining the water separator, the alarm continues while restarting system, unplug water level sensor cable located near the bottom of filter housing. Restart system and run for several minutes to clean metal elements of the water sensor. Plug cable in and check system. If system continues to sound an alarm after above procedure, repeat procedure and run system longer than before. Note: If this still fails to clear alarm refer to next Section (cleaning water level sensor) How to Clean Water Level Sensors Cleaning the water level sensors (located near the bottom of housing) will be required if the contacts become contaminated with dirt or water, and will not allow alarm to be reset or turned off. 1. Drain fuel from the water separator just below water sensor level. 2. Disconnect sensor cable on the side of filter housing. 3. Unscrew water level sensor and remove. 4. Clean metal contacts on sensor with shop towel, then replace. 5. Reconnect cable, start system and check for leaks. 9

REPLACEMENT FILTERS LIST Five Stages of Filtration: Stage 1 100 Mesh Stainless Steel - Replaceable Element in Filter Housing Stage 2 10-Micron - Particulate Removal Spin on Element Stage 3 3 Micron - Particulate Removal Spin on Element Stage 4 1-Micron Fine finish - Replaceable Element in Filter Housing Stage 5 Water Separation and removal - Replaceable Element in Filter Housing MODEL - FTI-5A Single Tank Stage 1 FL-30-100M (100 Mesh Strainer Element - 1 ea.) Stage 2 FL-30-10N (10 Micron Spin on - 1 ea.) Stage 3 FL-30-03N (3 Micron Spin on - 1 ea.) Stage 4 & 5 FL-FBO-60327 (1 micron & Water Separation Element - 1 ea.) To order Replacement Parts, please contact your FTI Representative. 10

TROUBLE SHOOTING GUIDE The following are answers to the most commonly asked questions about the FTI system and potential problems that may occur. System will not operate / Display is not working: 1. Check power source (24V DC) and circuit breaker in the FTI panel and wiring. If okay; Contact FTI representative. Display reads Filtering XX tank ON and pump/motor is not running: 1. Check pump/motor overload Contactor relay (located in control box) reset if needed. 2. Check motor over load button located on motor. (not on all motors) Leaks - Drip around or on bottom of filter: Water drip: 1. Check filter installation and tighten filter if necessary. If this does not stop the leak, check the filter seals. Clean or replace seals as necessary. 1. Close bottom drain valve on filter housing. Moisture around hose fittings: 1. Tighten hose fittings High Pressure Alarm: Vibration: 1. See alarm message descriptions. (Operations Manual, Alarm Message Descriptions) 1. Check pump-mounting bolts (and all other bolts). Tighten if necessary. Water sensor malfunction still comes on after draining water: 1. Follow the procedure using the Water Sensor Alarm Error (Alarm Will Not Shut off after Draining) to flush the sensor elements.) (Maintenance Manual) Note: If in doubt or if the problem cannot be resolved, please contact your FTI representative 11

LIMITED WARRANTY FUEL TECHNOLOGIES, INT. LLC (FTI) makes every effort to assure that its products meet high quality and durability standards, and we expressly warrant the original consumer/purchaser of our products that each product is free from defects in materials and workmanship. Our expressed warranty is subject to the following terms and conditions: 1. The term of our warranty is one year from the date of purchase. A warranty claim received by us after one year from the date of purchase will not be honored even if it is claimed that the defect occurred prior to one year from the date of purchase. 2. Our warranty does not cover defects due, directly or indirectly, to misuse, abuse, negligence of others, repairs or alterations done outside of our facilities, or lack of maintenance. 3. Our liability for breach of our express warranty is limited to the repair or replacement of the product, at our cost. 4. We are not liable for general, special, consequential, incidental or contingent damages resulting, directly or indirectly, from the purchase or use of our products. WE DISCLAIM ALL WARRANTIES OF MERCHANTABILITY AND FITNESS FOR ANY PURPOSE OF OUR PRODUCTS. To make a claim under this warranty, call our Customer Service Representative at 1-805-925-0531. We will ask you to advise us of our Distributor s name and address, the date of purchase, model number, and a detailed explanation of the problem you are experiencing. The Customer Service Representative will arrange for a Field engineer to inspect your system. If our inspection discloses a defect covered by our limited warranty, we will either repair or replace the defective parts of products at our election, and at our cost. If upon inspection, our Engineer determines there is not defect or that the damage to the system resulted from causes not within the scope of our limited warranty, then you must bear the cost of repair or replacement of damaged parts. For service, please contact your local Distributor. For your records Model No. Date of Purchase: Fuel Technologies International Box 6863, Santa Maria, CA 93456 (805) 925-0531 FAX (805) 435-1436 12