APRIL 2017 UNITEC PARTS COMPANY INSTALLATION PROCESS MANUAL UT-ID ABA6940CD Folding Door Restrictor Specifications

Similar documents
SEPTEMBER 22, 2010 UNITEC PARTS COMPANY INSTALLATION PROCESS MANUAL UT-ID ABA6940CD Folding Door Restrictor Specifications

APRIL 4, 2007 UT-ID Uni-Lock Mechanical Door Restrictor (4-Bar Linkage Version)

7300AC, A7777 (PWM), 7777 Resistance Control and Generic Installations to AT400 Door Operator Retrofit Kit

Dura-Glide SLH Slim Line Header Applications Guide

Safety Code for Existing Elevators and Escalators

BULLETIN INDEX LOCATOR

BULLETIN INDEX LOCATOR

CATALOG FOR PRESSURE CONTROL EQUIPMENT Supplement 2 LIFTING ACCESSORIES FOR BLOWOUT PREVENTERS AND SNUBBING STACKS TRADEMARK WOODCO BUY THE BRAND

BULLETIN INDEX LOCATOR

We recommend you keep a copy of this ordinance with you while you are off-roading.

September 8, Cessna Distributors, Authorized Service Facilities, CPC's, CSTARS, ASR's, and affected Owners of Record

BULLETIN INDEX LOCATOR

CHAPTER 4: ACCESSIBLE ROUTES

(2) For mounting heights suitable in schools and other facilities used primarily by children see section

The material incorporated by reference may be examined also at any state publications library.

BULLETIN INDEX LOCATOR

Door Restrictor Assembly. Model R2

Energy Briefing: World Crude Oil Outlays & Revenues

SUBSTATION INTERLOCKING SCHEMES

Report No: Test of: Reversible aluminium/timber window. Tested to: BS :2009 Performance of windows & doors Part 2: Operation & strength

Market Briefing: S&P 500 Bull & Bear Markets & Corrections

DART Charger Product Description, Information and Specification

Market Briefing: Mergers & Acquisitions World, Region, & Country

Fixed Ladder: A ladder that cannot be readily moved or carried because it is an integral part of a building or structure

SENATE, No STATE OF NEW JERSEY. 218th LEGISLATURE INTRODUCED APRIL 5, 2018

TANK RISER SUSPENSION SYSTEM CONCEPTUAL DESIGN (U)

Your interest is appreciated and hope the next 37 pages offers great profit potential for your new business. Copyright 2017 Frank Seghezzi

Global Index Briefing: MSCI Sectors Forward P/Es Selected Countries & Regions

Revision Transmittal Sheet

Installation Guide. Auxiliary Pressure Control Manifold on 6890 GC Accessory G1570A

DIVISION VI FINANCIAL MATTERS HYDRANT METER ACCOUNTS

BS EN :2006. Windows and doors Product standard, performance characteristics. A Report To: Mila Hardware Ltd. Document Reference:

TRAFFIC CONTROL REGULATIONS

2 cabs, 1 shaft, 0 crowds.

DC5000 Series. Cam Action Door Closer

US Economic Indicators: Durable Goods Orders & Shipments

Side Pin Code Keyway. System Registry Number. Key Set Symbol

Money & Credit: US Monetary Aggregates

City of Durango Hydrant Use Policy

626F Exit Device Trim Installation Instructions

RALEIGH COUNTY ALL-TERRAIN VEHICLES (ATV) ORDINANCE

Opening Quality Doors Around The World. Installation Instructions Bi-Parting Freight Doors - Q Style (Power and Manual)

MG 100. Spare parts list. Multi grapple. MG 100 s/n DEQ Construction Tools GmbH No

EEA AGREEMENT - ANNEX XIII p. 99 APPENDIX 2 { 1 }

US Economic Briefing: Regional Business Surveys

MOVFE 2500 LINEAR DOOR OPERATOR MECHANICAL MANUAL GAL CANADA

Vertabelo Academy. Terms of Service PLEASE READ ALL OF THE FOLLOWING TERMS OF SERVICE BEFORE USING THIS WEBSITE A. General Terms

US Economic Indicators: Manufacturing Production & Capacity by Major Industries

Temperature Life with or without Electrical Load Test Procedure for Electrical Connectors and Sockets

Home Elevator. Planning Guide

Jeep JL 3.5 Spring Lift

Jeep JL 4.5 Spring Lift

Chart Collection for Morning Briefing

Feeder Circuit Breaker Units Secure Support Pan and Change Door Latch

Model No EXPLORER POLY ATV CART. CAUTION: Read Rules for Safe Operation and Instructions Carefully

OWNERS MANUAL. Model No LB. PUSH BROADCAST SPREADER. Assembly Operation Maintenance Repair Parts

Town of Guilford 223 Marble Road Guilford, NY POLICY AND PROCEDURE. Vehicle Safety Policy & Procedure

Requirements for Secondary Voltage Revenue Metering (750 V and less)

100-30(02) (External Projections)

711. USE OF VEHICLES ON SCHOOL BUSINESS

Assembly Bill No CHAPTER 309. An act to amend Section of, and to add Section to, the Vehicle Code, relating to vehicles.

US Economic Briefing: Regional Business Surveys

Allen-Bradley Parts. CENTERLINE 2500 Motor Control Centers Installing, Joining and Splicing Columns. Installation Instructions. Catalog Number 2500

Jeep JL 3.5 Spring Lift

Agilent N2763A Rack Mount Kit for 4000 X-Series Oscilloscopes

Model No " LEAF/LAWNSWEEPER. Safety Assembly Operating Maintenance Repair Parts

Energy Briefing: US Petroleum Weekly Inventories

Toro Sprayer Calibration Tool

700 Type P & PK DC Relays Timer Units Latch Units Series A and B Construction. Renewal Parts

Market Briefing: Mergers & Acquisitions World, Region, & Country

US Economic Indicators: Manufacturing Production & Capacity by Major Industries

Parking Control Bylaw 2014

AVE MARIA STEWARDSHIP COMMUNITY DISTRICT

SERVICE BULLETIN REVISION TRANSMITTAL

DISCIPLINARY PENALTIES

US Economic Indicators: Merchandise Trade

MG 400. Spare parts list. Multi grapple. MG 400 s/n BGF Construction Tools GmbH No

Case: 2:16-cr ART-CJS Doc #: 3-1 Filed: 07/20/16 Page: 1 of 6 - Page ID#: 9

SERVICE LETTER. REASON To incorporate new software changes to the engine electronic control and engine diagnostics unit.

Our firm only processes the data that is required for the preparation, implementation and completion of the case in question.

JK Front SpeedBump Kit

Business ethics are an integral part of ABB s way of doing business

US Economic Indicators: Industrial Production & Capacity Utilization

ARTICLE TWENTY TWO ( 22 ) ORV ORDINANCE

JK Rear Trail Bar Part # Part #

US Economic Indicators: Railcar Loadings & Truck Tonnage

GRADE 3 TUBULAR LOCKSETS INDEX:

Door Closer Arms DC F95 (Non-Hold Open) Regular Arm Used with regular arm mounting (pull side) and top jamb mounting (push side)

DESCRIPTION OF OPERATION EcoSpace elevator with KCM831 control

GHA. Gas-Insulated Switchgear. Gas-Insulated Switchgear. Switchgear extension and replacement of a panel

Module T11. Movement of engineering trains and on-track plant under T3 arrangements. GE/RT8000/T11 Rule Book. Issue 2.

GENERAL PROVISIONS BLOCKING INTERSECTIONS OR MARKED SIDEWALKS.

2006 WORLD CHALLENGE SEASON

BC Spare parts list. Bucket crusher. BC 2500 s/n DEQ Construction Tools GmbH No

2008 Vehicle Technical Specifications

ELVORON HOME ELEVATOR

JL 2 Bumpstop Kit. Important Notes:

CHAPTER 71: TRAFFIC REGULATIONS

Spare parts list. Centrifugal pumps CP

Installation Information 2009 Model 300 Dumbwaiter

Transcription:

APRIL 2017 UNITEC PARTS COMPANY INSTALLATION PROCESS MANUAL ABA6940CD Folding Door Restrictor Specifications

APRIL 2017 ABA6940CD Folding Door Restrictor Specifications 212 West Newberry Road, Bloomfield, CT Phone 860.242.3632 Fax 860.286.1631 i

NONDISCLOSURE WARNING This work contains proprietary information and is the property of Otis Elevator Company. It is distributed only to those employees with a need to know the information and may not be reproduced, disclosed, or distributed to any person outside the employ of Otis Elevator Company without written authorization from an officer thereof. Otis competitors, customers, former employees, retirees, members of the general public and consultants not bound by a written nondisclosure agreement are among those outside the employ of Otis. In the event that an employee in the possession of this work no longer needs the information, retires, resigns, is terminated or laid off from Otis, or in the event that a person outside the employ of Otis comes into possession of this work, such employee or person should destroy the work or return it to Otis. Any unauthorized reproduction, disclosure or distribution by any person of any portion of this work may be a breach of a duty owed by such person to Otis Elevator Company and could result in damages actionable at law. PROHIBITION ON COPYING Any unauthorized reproduction, disclosure or distribution of copies by any person of any portion of the work may be a violation of Copyright Law of the United States of America and other countries, could result in the awarding of Statutory Damages of up to $250,000 (17 USC 504) for infringement and may result in further civil and criminal penalties. All rights reserved. PUBLICATION CATALOGING DATA First Issue: Master Index Control Number: Part Number: UT-ID21.3-500 Comments or questions about the information contained in this publication should be directed to: UNITEC 800-328-7840 Unpublished Work - Otis Elevator Company, 2017 ii

Page iii Table of Contents BACKGROUND... 1 REQUIREMENTS... 1 RUNNING AND DOOR CLEARANCES... 2 CAR DOOR SPACE... 2 INSTALLATION REQUIREMENTS... 2 SURVEY AND FLOOR-TO-FLOOR HEIGHT (FH) RESTRICTIONS... 3 ESTIMATING/ORDERING FOR STANDARD JOBS... 3 ESTIMATES... 3 PARTS ORDERING... 3 RELEVANT IDENTITIES... 8 APPENDIX A... 9 APPENDIX B... 10 iii

Page 1 BACKGROUND This UNITEC folding door restrictor when installed correctly, fully meets the requirements described in ASME(2016) A17.1 rule 2.12.1 and 2.14.5-7 and Appendix B. It is a completely maintenance free, passive device that has no moving parts when the elevator is in normal operation. The moving portion of the car door restrictor angle can be temporarily positioned (disengaged with locally supplied blocking), in order to make this a very maintenance mechanic friendly device. REQUIREMENTS WARNING: Under no circumstances shall angles from this kit be installed in a way that violates ANSI code. Generally, angles must be installed so car doors can open within 3.0-in. above and below each landing, but cannot open beyond 7 in. above and below each landing. Figure 1: Door Restrictor Free and Engaged Views

Page 2 Running and Door Clearances Installation requires approximately 5-1/4-in. (+/ - 1/8 in.) between car doors and hoistway doors with a standard 1-1/4 in. running clearance sill to sill. If space is smaller, tell UNITEC. They have a fix. Car door-to-hoistway sill nose must be greater than 2-3/4 in. Hoistway door-to-car sill nose must be greater than 3-3/8 in.. If space is smaller, tell UNITEC. They have a fix. A greater distance than 5-1/4 in. between the car and hoistway doors may be permissible, but field shimming of the car angle would be required. Shims for the car angle only are included in standard kits, if needed. Sill mounted closers for two-speed doors on the hoistway side can still be used with these restrictors. Arrangements now all incorporate the mounting of angles to the facia below sills with sill mounted closers. Car Door Space The window of space needed on the face of the car door. 84-in. entrance heights (EH). Window required is 6-in. wide (+/- 1/4 in.) by 52-in. (vertically from the trailing edge bottom of the driven car door panel and to ensure that no operator linkage passes through this space either). 96-in. entrance heights. Window required is 6-in. wide (+/- 1/4 in.) by 64-in. (measured from the trailing edge bottom of the driven car door panel and to ensure no operator linkage passes through this space). NOTE: If the above space is not available (for example - clearance for two speed door linkage) there is a possibility of application of equipment that takes up a smaller window of space on the car, but costs for hoistway angles go up significantly. Inquire on UNITEC. Installation Requirements To fasten a car restrictor angle to the driven car door requires eight screw fasteners. Two-speed doors fasten the car restrictor angle to the trailing edge of the fast speed door. Generally, two short hoistway angles need fastening to each hoistway door, and one shallow angle just beneath each hoistway sill. Each angle requires four screw fasteners. In some cases the fastening of one or more shallow reach angles (p/n ABA283ANE4) to the facia between floors is required.

Page 3 Survey and Floor-to-Floor Height (FH) Restrictions UNITEC does provide the special contract specifying of this product where the sill-to-sill floor heights fall outside the standard ranges indicated below: For 84-in. Entrances: Allowable sill-to-sill floor height range without specifying any extra facia angles is: 99-0 in. to 140 in. (11 ft. 8 in.) For 96-in. Entrances: Allowable sill-to-sill Floor Height range without specifying any extra facia angles is: 111 in. to 164 in. (13 ft. 8 in.) If any sill-to-sill floor height falls outside these ranges, UNITEC can still help you. Fill out the survey completely (see Appendix A) and fax UNITEC at 860-286-1625. If your entrance heights are not consistent (not all 84 in. +/- 1 in. or not all 96 in. +/- 1 in.), or are something other than 84 in. or 96 in., fill out survey completely and fax to UNITEC at 860-286-1625. ESTIMATING/ORDERING for STANDARD JOBS If your particular job falls within the standards mentioned above, the cost can now be estimated assuming: All entrance heights are either all 84 in. or all 96 in. and All sill-to-sill floor heights fall between the ranges shown above. Estimates Approximately $25.00 per floor for hoistway angles (includes the hardware cost) Approximately $300.00 per car angle (contains the hardware that is needed) Parts Ordering Table 1 lists the constant parts for both the 84-in. entrance height (floor height below 142.0 in.) and the 96-in. entrance height (floor height below 166.0 in.). Table 2 lists additional required parts for the indicated floor heights.

Page 4 Table 1: Constant Parts for 84-in. and 96-in. Entrance Heights Part Name Part Number Quantity 84 in. 96 in. Remarks Door Restrictor ABA6940CD1 1 --- ABA6940CD2 --- 1 per car opening Angle ABA283ANE1 2 per hoistway opening Angle ABA283ANE6 1 per hoistway opening Screw DIN7504KST6.3X19-A1B 12 per hoistway opening Table 2: Floor Height Conditional Parts with 84-in. and 96-in. Entrance Heights 84-in Entrance Height Floor Heights: > 140.0 in. 15 ft. 6 in. > 15 ft. 6 in. 19 ft. 4 in. >19 ft. 4 in. 23 ft. 2 in. 96-in Entrance Height Floor Heights: > 164.0 in. 18 ft. 6 in. > 18 ft. 6 in. 23 ft. 4 in. >23 ft. 4 in. 28 ft. 2 in. Part No. Part Name ABA283ANE4 Angle Quantity 1 2 3 Remarks Additional facia angles DIN7504KST6.3X19-A1B 4 Per angle NOTE: The total number of screws to be specified should equal four times the total number of angles. Contact UNITEC for floor heights above the last range listed.

Page 5 Figure 2: Hinged Car Angle Mounting (view from hoistway)

Page 6 Figure 3: Standard Door, View from Car

Page 7 Figure 4: Tall Door Heights

Page 8 Relevant Identities ABA6940CD1 and ABA6940CD2 ABA283ANE1, ABA283ANE4, ABA283ANE6 AAA316HMY1 (see Appendix B) AAA386MES1 (see Appendix B) AAA255MZ1 and AAA255MZ3 DIN7504KST6.3x19-A1B (Mounting screws must be ordered separately for the hoistway angles provided generally, 12 per opening (4 per angle) needed.) Example: for 10 openings with no extra facia angles order 120 screws. For each intermediate angle (ABA283ANE4), order four additional screws.

Page 9 APPENDIX A

Page 10 APPENDIX B Use the special angle (p/n AAA316HMY1) and plate (p/n AAA386MES1) if the hall door to nose of car threshold dimension is 3-3/8-in. or less in each location where a standard ABA283ANE1 angle would have been used. Select one of each p/n AAA316HMY1 and AAA386MES1. See Figure 5. Figure 5: Angle Mounted to Hoistway Door The assembly of the AAA316HMY1 base angle and AAA386MES1 plate provides a range of depth adjustment between a low of 2.35 in. and a high of 3.15 in. from the face of the hoistway doors. Figure 6: Top View of Angle Mounted to Hoistway Door Adjust the position of the AAA386MES1 plate so that it overhangs the sill by approximately 7/8 (0.875) of an inch (Figure 6). NOTE: Adjustment may vary depending on the sill clearance available as well as the protrusion of the car angle into the running clearance. Generally, 7/8 in. overhang into the running clearance is the standard arrangement in conjunction with an overlap of the car angle versus the hoistway angle of 0.41 inches (13/32).