Continuous level measurement Capacitance transmitters

Similar documents
Level Measurement. Continuous level measurement - Capacitance transmitters SITRANS LC500. 5/282 Siemens FI Overview.

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

Level Measurement Continuous level measurement - Capacitance transmitters

Level Measurement Point level measurement - RF Capacitance switches

Point level measurement Capacitance switches

Level Measurement. Point level measurement Capacitance switches. Pointek CLS300 Standard. 5/42 Siemens FI Overview.

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Level Measurement Point level measurement - RF Capacitance switches

Level Measurement Point level measurement - RF Capacitance switches

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 5/16 Siemens FI Overview.

Level Measurement Continuous level measurement Ultrasonic transmitters

SITRANS T measuring instruments for temperature

Level Measurement Continuous level measurement - Radar transmitters

Level Measurement Continuous level measurement Radar transmitters

Flow Measurement SITRANS F C

Level Probes multicap T DC 12 TE multicap T DC 11/16/21/26 TEN/TES

SITRANS P measuring instruments for pressure

Temperature Measurement Resistance thermometers

Motion sensors. Milltronics MFA 4p 6/17. Overview

Process Protection Motion sensors

SITRANS P measuring instruments for pressure

Mobrey MLT100. Displacer Level Transmitter. Product Data Sheet February 2015 IP119, Rev CA. Level, contents or interface measurement transmitter

Level limit switch Series RF 3000 Selection list

SITRANS F M. Flow sensor MAG 1100 F 3/59

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M. Flow sensor MAG 1100 F 4/57

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

Level instruments. Point level measurement - Vibrating switches SITRANS LVL100. 5/78 Siemens FI Horizontal mounting.

Process Protection Motion sensors

Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage

Rosemount 3051CFA Annubar Flowmeter

Pressure transmitter JUMO dtrans p02

Flow Measurement SITRANS F M. Flow sensor MAG /85. Overview

SATRON VT Pressure Transmitter

SATRON VDt Differential Pressure Transmitter

JUMO dtrans p02. Pressure transmitter. General application. Approvals/marks of conformity. Data Sheet Page 1/6. II 1/2G Ex ia IIC T6 Ga/Gb

Level Probes multicap DC 11/16/21/26 EN multicap DC 11/16/21/26 ES

Belt Scales Speed sensors

Product presentation SITRANS P310

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >

Series 3730 Electropneumatic Positioner Type

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

SITRANS L Level instruments

Belt Scales Speed sensors

Process Protection. 7/2 Product overview. 7/3 Acoustic and motion sensing. Acoustic sensor for pump monitoring 7/5 SITRANS DA400

SATRON VVFe Pressure Transmitter

Flow Measurement SITRANS F C

VersaFlow Vortex 100 Vortex Flow Meter Specifications

Level Probes multicap T DC 12 TA multicap T DC 11/16/21/26 TAN/TAS

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet

Series Level-Trol Electronic Liquid Level Transmitters

BM 26 BASIC/ADVANCED Technical Datasheet

POSITIONERS and Controls for Complete Valve Automation

Positioners Converters Limit Switches Position Transmitters Solenoid Valves Accessories. Selection and Application

Flow Measurement SITRANS F C. Flow sensor MASS 2100 DI 3 to DI 40. 4/180 Siemens FI

Smart Pressure Transmitter

TECHNICAL BULLETIN. Logix 510si Series Digital Positioner. Experience In Motion FCD LGENTB /09

Process Protection Motion sensors

OPTISWITCH 4000/5000. Vibration level switches for liquids

BM 26 BASIC/ADVANCED Technical Datasheet

Micro Motion F-Series Coriolis Flow and Density Meters

Rosemount 3051T In-Line Pressure Transmitter

Field IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage

Smart Pressure Transmitter

Masoneilan Series

STEEMCO-MAS Flowmeter for Steam

Metal tube variable area flowmeter for gases, liquids and steam

V200 Positioner. V200 P Pneumatic Positioner. V200 E Electropneumatic Positioner. Housing Material: Cast aluminium with polyester coating

JUMO dtrans p20 DELTA

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

SITRANS F X SITRANS FX300 3/355

Flow Measurement SITRANS F M

SITRANS F C. Flow sensor MC2 4/193. Overview

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T

STEEMCO Flowmeter for Steam

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

L E V E L P L U S M - S E R I E S ANALOG

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

Rosemount DP Level Transmitters and 1199 Seal Systems

JUMO dtrans p20. Process pressure transmitter. Brief description. Special features. Block diagram. Approvals/approval marks (see "Technical data")

Rosemount DP Level Transmitters and 1199 Remote Seals

Rosemount 3051S Electronic Remote Sensor (ERS) System

Differential pressure transmitter PASCAL Ci4 Delta P

Smart Pressure Transmitter

Level Measurement Point level measurement - Vibrating switches

Level Probe multicap DC 16

TEK-B AR 3110A. Differential Pressure Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys PRESSURE

Process connection. Further designs. Order code. to EN

Rosemount 3051S Series of Instrumentation

Oscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids

Metal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam

TECHNICAL BULLETIN. Logix 520MD Series Digital Positioner. Experience In Motion FCD LGENTB /09

Flap-Type Flow Meter Prall

Flow Measurement SITRANS F X SITRANS FX300 4/365

OPTIMASS 3000 Technical Datasheet

Mineral-Insulated RTD Temperature Probe According to DIN EN 60751

TWL-Exia. Resistance Thermometers according to DIN. Ignition Protection Exia. Pt 100-sensor class A respectively class B

Transcription:

Siemens AG 2011 Level Measurement SITRANS LC00 Overview Configuration Installation Build up of material or condensation in active shield area does not affect switch operation. SITRANS LC00 is an inverse frequency shift capacitance level or interface transmitter for extreme and critical process conditions, such as oil and liquified natural gas (LNG) as well as toxic and aggressive chemicals and vapours. Mounting on non-linear vessels in non-conductive fluids using stilling well. Benefits Patented Active-Shield technology so measurement is unaffected by material buildup in active shield section Simple push-button calibration and integrated local display Inverse frequency approach provides high resolution 2-wire loop powered 4 to 20/20 to 4 ma measurement signal Pre-detection alarm and full function diagnostics High temperature and pressure resistant (optional) SITRANS LC00 installation Technical specifications Input Measuring range Span Output Solid-state switch 1 3300 pf Min. 3.3 pf Full-function diagnostics comply with NAMUR NE 43 Output Galvanically isolated Easy calibration locally or via HART Protection Bipolar (using SIMATIC PDM software) Max. switching voltage 30 V (DC) 30 V peak (AC) Application Max. load current 82 ma SITRANS LC00 s advanced electronics provide one-step, Voltage drop < 1 V, typical at 0 ma push-button calibration and local display for easy on-site installation and setup. Time delay (pre or post switching) 1 60 s Loop current 3.6 22 ma/22 3.6 ma The unique mechanical probe design coupled with a high performance transmitter gives superior performance in toxic and (2-wire current loop) aggressive chemicals, acids, caustics, adhesives and in viscous conductive and non-conductive materials. Accuracy (transmitter) Temperature stability 0.1 pf (0 pf) or < 0.2% (typically < 0.1%) of actual measured value, whichever is greater The SMART 2-wire transmitter has HART communications for remote commissioning and inspection. over the full temperature range Key Applications: Oil/water or foam/liquid interface measurement in separators or coalescers, cryogenic applications in- measured value respectively Non-linearity and repeatability < 0.1% of range and actual cluding CO 2 and liquified natural gas (LNG), distillation/regeneration tanks with high temperatures Accuracy Deviation < 0.1% of measured value Siemens FI 01 2012 /311

Level Measurement SITRANS LC00 Siemens AG 2011 Rated operating conditions Installation conditions Location Indoor/outdoor Ambient conditions Ambient temperature (transmitter) -40 +8 C (-40 +18 F) 2) Installation category II Pollution degree 4 Medium conditions Relative dielectric constant ε r Min. 1. Process temperature Temperature rating of process seal is pressure dependent. See Pressure/Temperature curves on page /321. - Standard (PFA) 3) -0 +200 C (-8 +392 F) - Cryogenic version -200 +200 C (-328 +392 F) Contact ceg.smpi@siemens.com for details. Process pressure Pressure rating of process seal is temperature dependent. See Pressure/Temperature curves on page /321. Standard (PFA) -1 10 bar g (217 psi g) Design Material Wetted parts material - Standard rod 316L stainless steel Probe insulation (rod) PFA Cable 316 stainless steel/ 316 stainless steel PFA Probe diameter Rod version 16 mm (0.63 inch) or 24 mm (0.9 inch) Cable version 9 mm (0.3 inch) with PFA jacket, 6 mm (0.24 inch) without PFA jacket Active shield length Minimum (rod version) 0 mm (1.97 inch), customer selectable (order number Y02) Probe length Rod version Max. 3. m (138 inch) with 16 mm rod, PFA Max.. m (216 inch) with 24 mm rod, PFA Cable version Max. 3 m (1378 inch) Process connection of probe Threaded mounting NPT [(Taper), ANSI/ASME B1.20.1] R [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] G [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] Flange mounting ASME, EN 1092-1 Enclosure Material Aluminium, epoxy-coated Cable inlet 2 x ½" NPT (2 x M20x1., IP68 adapter, optional) Degree of protection Type 4X/NEMA4X/IP6, IP68 Power supply 12 33 V DC User Interface Display Local LCD, 4 digit, each 0 9 and limited alpha characters Rotary function switch For selecting programmable menu items Push buttons Red +, blue -, used in conjunction with rotary switch for programming Features Measurement current signalling According to NAMUR NE 43, signal 3.8 20. ma, fault 3.6 or 21 ma (22 ma) Safety Inputs/outputs fully galvanically isolated Polarity-insensitive current loop Fully potted Integrated safety barrier Diagnostics with fault alarm when: Primary variable (PV) out of limits, system failure in measurement circuit, deviation between A/D and D/A converter, check sum, watch dog and self-checking facility Function rotary switch Positions 0 9, A F SMART communication Conforming to HART Communication Foundation (HCF) Certificates and approvals General Purpose CE, CSA, FM, C-TICK Non-incendive/Non-sparking CSA/FM Class 1, Div. 2, Groups A, B, C, D T4 ATEX II 3G 2D EEx na [ib] IIC T6 T4 T100 C Dust Ignition Proof (Intrinsically Safe Probe Circuit) Explosion Proof (Intrinsically Safe Probe Circuit) Marine CSA/FM Class II and III, Div. 1, Groups E, F, G ATEX II 1/2 GD EEx d [ia] T6 T1 T100 C FM Class 1, Div. 1, Groups A, B, C, D T4 ATEX II 1/2 GD EEx d [ia] IIC T6 T1 Lloyds Register of Shipping, Categories ENV1, ENV2, ENV3 and ENV, Bureau Veritas When operation is in areas classified as hazardous, observe restrictions according to relevant certificate. See also Pressure/Temperature curves on page /321. 2) Thermal isolator is used if process connection temperature exceeds +8 C (+18 F). 3) Not recommended for steam environments /312 Siemens FI 01 2012

Siemens AG 2011 Level Measurement SITRANS LC00 SITRANS LC00 probe version Standard Extended Cable version with Rod Sensor Process connection types Threaded or welded flange Single piece flanged Threaded or welded flange Threaded Available as standard Available as standard Flange Available as standard Available as standard Available as standard Process connection materials Stainless steel 316L Available as standard Available as standard Available as standard Probe insulation PFA Available as standard Available as standard Available as standard Length and Process parameters Rod length for PFA 16 mm version Rod length for PFA 24 mm version Cable length Min. 200 mm (7.87 inch) Max. 3 00 mm (137.80 inch) Min. 200 mm (7.87 inch) Max. 00 mm (216.4 inch) Min. 1 000 mm (39.37 inch) Max. 3 000 mm (1377.9 inch) Min. 200 mm (7.87 inch) Max. 3 00 mm (137.80 inch) Min. 200 mm (7.87 inch) Max. 00 mm (216.4 inch) Min. 1 000 mm (39.37 inch) Max. 3 000 mm (1377.9 inch) See Pressure/Temperature curves for specific probe type 2) Refers to total insertion length. See dimension drawing on page /331 for further explanation - Not available as standard Min. 200 mm (7.87 inch) Max. 3 00 mm (137.80 inch) Min. 200 mm (7.87 inch) Max. 00 mm (216.4 inch) Min. 000 mm (196.8 inch) 2) Max. 3 000 mm (1377.9 inch) 2) Maximum process pressure See Pressure/Temperature curves for specific probe type bar g (73 psi g) Maximum process temperature +100 C (+212 F) Siemens FI 01 2012 /313

Level Measurement SITRANS LC00 Siemens AG 2011 Order No. SITRANS LC00, Threaded or Welded Flange C) 7ML13- with Cable Sensor Inverse frequency shift capacitance level and interface transmitter for extreme and critical process 7 7 7 77-77 7 7 conditions, such as oil and liquid gas, toxic and aggressive chemicals and vapours. Version Cable, 9 mm (0.3 inch) diameter, 316 stainless steel with PFA insulation, weighted Add order code Y01 and plain text: "Insertion length... mm" 1000... 2000 mm (39.37... 78.74 inch) 0 E 2001... 4000 mm (78.78... 17.48 inch) 1 E 4001... 6000 mm (17.2... 236.22 inch) 2 E 6001... 8000 mm (236.26... 314.96 inch) 3 E 8001... 10000 mm (31... 393.70 inch) 4 E Longer lengths possible to a max. of 3000 mm (114.83 ft). Contact ceg.smpi@siemens.com for details. Cable, 6 mm (0.24 inch) diameter, 316L stainless steel, non-insulated, weighted (non-conductive media only) Add order code Y01 and plain text: "Insertion length... mm" 1000... 2000 mm (39.37... 78.74 inch) 2) 0 F 2001... 4000 mm (78.78... 17.48 inch) 2)3) 1 F 4001... 6000 mm (17.2... 236.22 inch) 2)3) 2 F 6001... 8000 mm (236.26... 314.96 inch) 2)3) 3 F 8001... 10000 mm (31... 393.70 inch) 2)3) 4 F Cable lengths up to 2000 mm (984.2 inch) are possible for non-conductive media. Cable lengths up to 1000 mm (90. inch) are possible for conductive media. Contact ceg.smpi@siemens.com for details. Process connection (316L Stainless steel) Threaded connection 1½" NPT [(Taper), ANSI/ASME B1.20.1] C 0 R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] F 0 1¼" NPT [(Taper), ANSI/ASME B1.20.1] K 0 G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B L 0 0202] Welded flange, raised face 1½", ASME, 10 Ib B 1 1½", ASME, 300 Ib B 2 1½", ASME, 600 Ib B 3 2", ASME, 10 Ib C 1 2", ASME, 300 Ib C 2 2", ASME, 600 Ib C 3 3", ASME, 10 Ib 3) D 1 3", ASME, 300 Ib 3) D 2 3", ASME, 600 Ib 3) D 3 4", ASME, 10 Ib 3) E 1 4", ASME, 300 Ib 3) E 2 4", ASME, 600 Ib 3) E 3 6", ASME, 10 Ib 3) F 1 6", ASME, 300 Ib 3) F 2 6", ASME, 600 Ib 3) F 3 Welded flange, Type A flat faced DN 40, PN 16 K 4 DN 40, PN 40 K DN 0, PN 16 L 4 DN 0, PN 40 L DN 80, PN 16 M 4 DN 80, PN 40 3) M DN 100, PN 16 3) N 4 DN 100, PN 40 3) N DN 12, PN 16 3) P 4 DN 12, PN 40 3) P (Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16., or EN 1092-1 standard.) Order No. SITRANS LC00, Threaded or Welded Flange C) 7ML13- with Cable Sensor Inverse frequency shift capacitance level and interface transmitter for extreme and critical process 7 7 7 77-77 7 7 conditions, such as oil and liquid gas, toxic and aggressive chemicals and vapours. Approvals General Purpose: CE, CSA, FM, C-TICK, KC 1 CSA / FM Class I, Div 2, Groups A, B, C, D 2 CSA / FM Class II, III, Div 1, Groups E, F, G T4 ATEX II 3G 2D EEx na [ib] IIC T6... T4 T 100 C ATEX II 1/2 GD EEx d [ia] IIC T6... T1 T 100 C 4 FM Class I, Div.1, Groups A, B, C, D, T4 6 Enclosure/Cable inlet Aluminum epoxy coated 2 x ½" NPT, IP68 1 2 x M20x1. (IP68, adapter) 2 Options No additional options A With mounting eye 4) B Thermal isolator Without thermal isolator A Isolator, only for use when temperature range is B outside of -40... +8 C (-40... +18 F), explosion proof approval -40... +70 C (-40... +18 F) Electronic output 2-wire loop current 4... 20 ma 1 (transmitter MSP 2002-2 _3300 pf) A minimum span of 3 pf must be maintained 2) Available with non-conductive media only 3) Custom shipping methods required. Contact factory for more details. 4) Available in PFA insulated version only C) Subject to export regulations AL: N, ECCN: EAR99. Order code Further designs Please add "-Z" to Order No. and specify Order code(s). Insertion length, specify in plain text: Y01:... mm Y01 Stainless steel tag [69 x 0 mm (2.71 x 1.97 inch)]: Y1 Measuring-point number/identification (max. 16 characters) specify in plain text Acceptance test certificate: Manufacturer's test C11 certificate M to DIN 30, Part 18 and ISO 9000 Inspection Certificate Type 3.1 per EN 10204 C12 Operating Instructions See page /320 Accessories See page /320 /314 Siemens FI 01 2012

Siemens AG 2011 Level Measurement SITRANS LC00 Order No. SITRANS LC00, Threaded or Welded Flange, C) 7ML1- with Rod Sensor Inverse frequency shift capacitance level and interface transmitter for extreme and critical process 7 7 7 77-77 7 7 conditions, such as oil and liquid gas, toxic and aggressive chemicals and vapours. Version Rod, 16 mm (0.63 inch), PFA insulated Add order code Y01 and Y02 and plain text: "Insertion length... mm and active shield length... mm" 200... 1000 mm (7.87... 39.37 inch) 0 A 1001... 2000 mm (39.41... 78.74 inch) 1 A 2001... 3000 mm (78.78... 118.11 inch) 2) 2 A 3001... 300 mm (118.1... 137.80 inch) 2) 3 A Rod, 16 mm (0.63 inch), PFA insulated with 3 mm (1.38 inch) stilling well in 316L stainless steel Add order code Y01 and Y02 and plain text: "Insertion length... mm and active shield length... mm" 200... 1000 mm (7.87... 39.37 inch) 3) 0 B 1001... 2000 mm (39.41... 78.74 inch) 3) 1 B 2001... 3000 mm (78.78... 118.11 inch) 2)3) 2 B 3001... 300 mm (118.1... 137.80 inch) 2)3) 3 B Rod, 24 mm (0.94 inch), PFA insulated Add order code Y01 and Y02 and plain text: "Insertion length... mm and active shield length... mm" 200... 1000 mm (7.87... 39.37 inch) 4) 0 C 1001... 2000 mm (39.41... 78.74 inch) 4) 1 C 2001... 3000 mm (78.78... 118.11 inch) 2)4) 2 C 3001... 4000 mm (118.1... 17.48 inch) 2)4) 3 C 4001... 000 mm (173.26... 196.88 inch) 2)4) 4 C 001... 00 mm (196.89... 216.4 inch) 2)4) C Rod, 24 mm (0.94 inch), PFA insulated with 48 mm (1.89 inch) stilling well in 316L stainless steel Add order code Y01 and Y02 and plain text: "Insertion length... mm and active shield length... mm" 200... 1000 mm (7.87... 39.37 inch) ) 0 D 1001... 2000 mm (39.41... 78.74 inch) ) 1 D 2001... 3000 mm (78.78... 118.11 inch) 2)) 2 D 3001... 4000 mm (118.1... 17.48 inch) 2)) 3 D 4001... 000 mm (173.26... 196.88 inch) 2)) 4 D 001... 00 mm (196.89... 216.4 inch) 2)) D Process connection (316L Stainless steel) Threaded connection ¾" NPT [(Taper), ANSI/ASME B1.20.1] A 0 1" NPT [(Taper), ANSI/ASME B1.20.1] B 0 1½" NPT [(Taper), ANSI/ASME B1.20.1] C 0 2" NPT [(Taper), ANSI/ASME B1.20.1] D 0 R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] E 0 R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] F 0 R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] J 0 R 2" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] K 0 1¼" NPT [(Taper), ANSI/ASME B1.20.1] N 0 G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] P 0 G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] R 0 G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), S 0 JIS B 0202] G 2" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] T 0 Order No. SITRANS LC00, Threaded or Welded Flange, C) 7ML1- with Rod Sensor Inverse frequency shift capacitance level and interface transmitter for extreme and critical process 7 7 7 77-77 7 7 conditions, such as oil and liquid gas, toxic and aggressive chemicals and vapours. Welded flange, raised face 1½", ASME, 10 Ib B 1 1½", ASME, 300 Ib B 2 1½", ASME, 600 Ib B 3 2", ASME, 10 Ib C 1 2", ASME, 300 Ib C 2 2", ASME, 600 Ib C 3 3", ASME, 10 Ib 2) D 1 3", ASME, 300 Ib 2) D 2 3", ASME, 600 Ib 2) D 3 4", ASME, 10 Ib 2) E 1 4", ASME, 300 Ib 2) E 2 4", ASME, 600 Ib 2) E 3 6", ASME, 10 Ib 2) F 1 6", ASME, 300 Ib 2) F 2 6", ASME, 600 Ib 2) F 3 Welded flange, Type A flat faced DN 40, PN 16 K 4 DN 40, PN 40 K DN 0, PN 16 L 4 DN 0, PN 40 L DN 80, PN 16 M 4 DN 80, PN 40 2) M DN 100, PN 16 2) N 4 DN 100, PN 40 2) N DN 12, PN 16 2) P 4 DN 12, PN 40 2) P (Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16., or EN 1092-1 standard.) Approvals General Purpose: CE, CSA, FM, C-TICK, KC 1 CSA / FM Class I, Div 2, Groups A, B, C, D 2 CSA / FM Class II, III, Div 1, Groups E, F, G T4 ATEX II 3G 2D EEx na [ib] IIC T6... T4 T 100 C ATEX II 1/2 GD EEx d [ia] IIC T6... T1 T 100 C 4 FM Class I, Div.1, Groups A, B, C, D, T4 6 Enclosure/Cable inlet Aluminum epoxy coated 2 x ½" NPT, IP68 1 2 x M20 x1. (IP68, adapter) 2 Options No additional options A Slotted holes instead of standard vent holes in stilling well (refer to Operating Instructions for dimen- B sions.) 6) Thermal isolator/remote version Without thermal isolator or remote electronics A Thermal isolator, only for use when temperature B range is outside of -40... +8 C (-40... +18 F), explosion proof approval -40... +70 C (-40... +18 F) Remote electronics with mounting bracket and cable 7) Length: 2 m (79 inch) C Length: 3 m (118 inch) D Length: 4 m (18 inch) E Length: m (197 inch) F Siemens FI 01 2012 /31

Level Measurement SITRANS LC00 Siemens AG 2011 Order No. SITRANS LC00, Threaded or Welded Flange, C) 7ML1- with Rod Sensor Inverse frequency shift capacitance level and interface 7 7 7 77-77 7 7 transmitter for extreme and critical process conditions, such as oil and liquid gas, toxic and aggressive chemicals and vapours. Electronic output 2-wire loop current 4... 20 ma 1 (transmitter MSP 2002-2 _3300 pf) A minimum span of 3 pf must be maintained 2) Custom shipping methods required. Contact factory for more details. 3) Available with process connection 1½" or larger 4) Available with process connection 1" or larger ) Available with process connection 2" or larger 6) Available with version 0B 3B, 0D D and 0F only 7) Available with approval option 1 only C) Subject to export regulations AL: N, ECCN: EAR99. Order code Further designs Please add "-Z" to Order No. and specify Order code(s). Insertion length, specify in plain text: Y01:... mm Y01 Active shield length, specify in plain text [min. Y02 length is 0 mm (2 inch)]: Y02:... mm Stainless steel tag [69 x 0 mm (2.71 x 1.97 inch)]: Y1 Measuring-point number/identification (max. 16 characters) specify in plain text Acceptance test certificate: Manufacturer's test C11 certificate M to DIN 30, Part 18 and ISO 9000 Inspection Certificate Type 3.1 per EN 10204 C12 Manufacturing Test Report (Electrode Test) C18 Operating Instructions See page /320 Accessories See page /320 /316 Siemens FI 01 2012

Siemens AG 2011 Level Measurement SITRANS LC00 Order No. SITRANS LC00, Single Piece Flanged with Rod C) 7ML17- Sensor 7 7 7 77-7 7 7 7 Inverse frequency shift capacitance level and interface transmitter for extreme and critical process conditions, such as oil and liquid gas, toxic and aggressive chemicals and vapours. Version Rod, 16 mm (0.63 inch), PFA insulated Add order code Y01 and Y02 and plain text: "Insertion length... mm and active shield length... mm" 20... 1000 mm (9.84... 39.37 inch) 0 A 1001... 2000 mm (39.41... 78.74 inch) 1 A 2001... 3000 mm (78.78... 118.11 inch) 2) 2 A 3001... 300 mm (118.1... 137.80 inch) 2) 3 A Rod, 16 mm (0.63 inch), PFA insulated with 3 mm (1.34 inch) stilling well in 316L stainless steel Add order code Y01 and Y02 and plain text: "Insertion length... mm and active shield length... mm" 20... 1000 mm (9.84... 39.37 inch) 0 B 1001... 2000 mm (39.41... 78.74 inch) 1 B 2001... 3000 mm (78.78... 118.11 inch) 2) 2 B 3001... 300 mm (118.1... 137.80 inch) 2) 3 B Rod, 24 mm (0.94 inch), PFA insulated Add order code Y01 and Y02 and plain text: "Insertion length... mm and active shield length... mm" 20... 1000 mm (9.84... 39.37 inch) 0 C 1001... 2000 mm (39.41... 78.74 inch) 1 C 2001... 3000 mm (78.78... 118.11 inch) 2) 2 C 3001... 4000 mm (118.1... 17.48 inch) 2) 3 C 4001... 000 mm (173.26... 196.88 inch) 2) 4 C 001... 00 mm (196.89... 216.4 inch) 2) C Rod, 24 mm (0.94 inch), PFA insulated with 48 mm (1.89 inch) stilling well in 316L stainless steel Add order code Y01 and Y02 and plain text: "Insertion length... mm and active shield length... mm" 20... 1000 mm (9.84... 39.37 inch) 0 D 1001... 2000 mm (39.41... 78.74 inch) 2)3) 1 D 2001... 3000 mm (78.78... 118.11 inch) 2)3) 2 D 3001... 4000 mm (118.1... 17.48 inch) 2)3) 3 D 4001... 000 mm (173.26... 196.88 inch) 2)3) 4 D 001... 00 mm (196.89... 216.4 inch) 2)3) D Process connection (316L Stainless steel) Single piece flange, raised face 1½", ASME, 10 Ib B 1 1½", ASME, 300 Ib B 2 1½", ASME, 600 Ib B 3 2", ASME, 10 Ib C 1 2", ASME, 300 Ib C 2 2", ASME, 600 Ib C 3 3", ASME, 10 Ib 2) D 1 3", ASME, 300 Ib 2) D 2 3", ASME, 600 Ib 2) D 3 4", ASME, 10 Ib 2) E 1 4", ASME, 300 Ib 2) E 2 4", ASME, 600 Ib 2) E 3 6", ASME, 10 Ib 2) F 1 6", ASME, 300 Ib 2) F 2 6", ASME, 600 Ib 2) F 3 Order No. SITRANS LC00, Single Piece Flanged with Rod C) 7ML17- Sensor Inverse frequency shift capacitance level and interface 7 7 7 77-7 7 7 7 transmitter for extreme and critical process conditions, such as oil and liquid gas, toxic and aggressive chemicals and vapours. Single piece flange, Type B1 raised face DN 40, PN 16 K 4 DN 40, PN 40 K DN 0, PN 16 L 4 DN 0, PN 40 L DN 80, PN 16 M 4 DN 80, PN 40 2) M DN 100, PN 16 2) N 4 DN 100, PN 40 2) N DN 12, PN 16 2) P 4 DN 12, PN 40 2) P Single piece flange with PTFE flange facing (applicable with versions 0A... 3A and 0C... C) 4) 1½", ASME, 10 Ib B 4 1½", ASME, 300 Ib B 1½", ASME, 600 Ib B 6 2", ASME, 10 Ib C 4 2", ASME, 300 Ib C 2", ASME, 600 Ib C 6 3", ASME, 10 Ib 2) D 4 3", ASME, 300 Ib 2) D 3", ASME, 600 Ib 2) D 6 4", ASME, 10 Ib 2) E 4 4", ASME, 300 Ib 2) E 4", ASME, 600 Ib 2) E 6 6", ASME, 10 Ib 2) F 4 6", ASME, 300 Ib 2) F 6", ASME, 600 Ib 2) F 6 Single piece flange with PTFE flange facing (applicable with versions 0A... 3A, 0C... C) 4) DN 40, PN 16 K 6 DN 40, PN 40 K 7 DN 0, PN 16 L 6 DN 0, PN 40 L 7 DN 80, PN 16 M 6 DN 80, PN 40 2) M 7 DN 100, PN 16 2) N 6 DN 100, PN 40 2) N 7 DN 12, PN 16 2) P 6 DN 12, PN 40 2) P 7 (Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16., or EN 1092-1 standard.) Siemens FI 01 2012 /317

Level Measurement SITRANS LC00 Siemens AG 2011 Order No. SITRANS LC00, Single Piece Flanged with Rod C) 7ML17- Sensor 7 7 7 77-7 7 7 7 Inverse frequency shift capacitance level and interface transmitter for extreme and critical process conditions, such as oil and liquid gas, toxic and aggressive chemicals and vapours. Approvals General Purpose: CE, CSA, FM, C-TICK, KC 1 CSA / FM Class I, Div 2, Groups A, B, C, D 2 CSA / FM Class II, III, Div 1, Groups E, F, G T4 ATEX II 3G 2D EEx na [ib] IIC T6... T4 T 100 C ATEX II 1/2 GD EEx d [ia] IIC T6... T1 T 100 C 4 FM Class I, Div.1, Groups A, B, C, D, T4 6 Enclosure/Cable inlet Aluminum epoxy coated 2 x ½" NPT, IP68 1 2 x M20 x1. (IP68, adapter) 2 Options None A Slotted holes instead of standard vent holes in B stilling well (Refer to manual for dimensions) ) Thermal isolator/remote version Without thermal isolator A Isolator, only for use when temperature range is B outside of -40... +8 C (-40... +18 F), explosion proof approval -40... +70 C (-40... +18 F) Remote electronics with mounting bracket and cable 6) Length: 2 m (79 inch) C Length: 3 m (118 inch) D Length: 4 m (18 inch) E Length: m (197 inch) F Electronic output 2-wire loop current 4... 20 ma 1 (transmitter MSP 2002-2 _3300 pf) A minimum span of 3 pf must be maintained 2) Custom shipping methods required. Contact factory for more details. 3) Available with process connection 2" or larger, and only available with process connection options C1 to F3, L4 to P 4) Not available with versions 0E and 0F ) Available with version 0B to 3B, 0D to D and 0F only 6) Available with approval option 1 only C) Subject to export regulations AL: N, ECCN: EAR99. Order code Further designs Please add "-Z" to Order No. and specify Order code(s). Insertion length, specify in plain text: Y01:... mm Y01 Active shield length, specify in plain text Y02 [min. length is 0 mm (2 inch)]: Y02:... mm Stainless steel tag [69 x 0 mm (2.71 x 1.97 inch)]: Y1 Measuring-point number/identification (max. 16 characters) specify in plain text Acceptance test certificate: Manufacturer's test C11 certificate M to DIN 30, Part 18 and ISO 9000 Inspection Certificate Type 3.1 per EN 10204 C12 Manufacturing Test Report (Electrode Test) C18 Operating Instructions See page /320 Accessories See page /320 /318 Siemens FI 01 2012

Siemens AG 2011 Level Measurement SITRANS LC00 Order No. SITRANS LC00, Extended Cable version with C) 7ML23- Rod Sensor, threaded connection or welded flange 7 7 7 77-77 7 7 Inverse frequency shift capacitance level and interface transmitter for short range continuous measurement in large storage vessels. Version 2) Rod, 16 mm (0.63 inch), PFA insulated and 316L stainless steel flexible extension tube Total insertion length: Add order code Y01 and/314ain text: "Total insertion length... mm and Y02 and plain text: Active shield length... mm" 3)4) 000... 10000 mm (196.8... 393.70 inch) 0 A 10001... 1000 mm (393.74... 90. inch) 1 A 1001... 20000 mm (90.9... 787.40 inch) 2 A 20001... 2000 mm (787.44... 984.2 inch) 3 A 2001... 30000 mm (984.29... 1181.10 inch) 4 A 30001... 3000 mm (1181.14... 1377.9 inch) A Rod, 24 mm (0.94 inch), PFA insulated and 316L stainless steel flexible extension tube Total insertion length: Add order code Y01 and plain text: "Total insertion length... mm and Y02 and plain text: Active shield length... mm" 3)4) 000... 10000 mm (196.8... 393.70 inch) 0 B 10001... 1000 mm (393.74... 90. inch) 1 B 1001... 20000 mm (90.9... 787.40 inch) 2 B 20001... 2000 mm (787.44... 984.2 inch) 3 B 2001... 30000 mm (984.29... 1181.10 inch) 4 B 30001... 3000 mm (1181.14... 1377.9 inch) B Process connection (316L stainless steel) Threaded connection 2" NPT [(Taper), ANSI/ASME B1.20.1] A 0 R 2" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] B 0 G 2" [(BSPP), EN ISO 228-1/PF (JIS-P) JIS B 0202] D 0 Welded flange, raised face 2", ASME, 10 Ib C 1 2", ASME, 300 Ib C 2 3", ASME, 10 Ib D 1 3", ASME, 300 Ib D 2 4", ASME, 10 Ib E 1 4", ASME, 300 Ib E 2 6", ASME, 10 Ib F 1 6", ASME, 300 Ib F 2 Welded flange, Type A flat faced DN 0, PN 16 L 4 DN 0, PN 40 L DN 80, PN 16 M 4 DN 80, PN 40 M DN 100, PN 16 N 4 DN 100, PN 40 N DN 12, PN 16 P 4 DN 12, PN 40 P (Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16., or EN 1092-1 standard.) Approvals General Purpose: CE, CSA, FM, C-TICK, KC 1 CSA / FM Class I, Div 2, Groups A, B, C, D 2 CSA / FM Class II, III, Div 1, Groups E, F, G T4 ATEX II 3G 2D EEx na [ib] IIC T6... T4 T 100 C ATEX II 1/2 GD EEx d [ia] IIC T6... T1 T 100 C 4 FM Class I, Div 1, Groups A, B, C, D T4 6 Order No. SITRANS LC00, Extended Cable version with C) 7ML23- Rod Sensor, threaded connection or welded flange 7 7 7 77-77 7 7 Inverse frequency shift capacitance level and interface transmitter for short range continuous measurement in large storage vessels. Enclosure/Cable inlet Aluminum epoxy coated 2 x ½" NPT, IP68 1 2 x M20x1. (IP68, adapter) 2 Options No additional options A With mounting eye B Thermal isolator Without thermal isolator Isolator, only for use when temperature range is outside of -40... +8 C (-40... +18 F), explosion proof approval -40... +70 C (-40... +18 F) Electronic output 2-wire loop current 4... 20 ma (transmitter MSP 2002-2 _3300 pf) Custom shipping methods required. Contact factory for more details. 2) A minimum span of 3 pf must be maintained. 3) See dimension drawings on page /331 for further explanation of Y01. 4) Inactive length is equal to the flexible extension plus transition. See dimension drawings on page /331 for further explanation of Y02. A B 1 Siemens FI 01 2012 /319

Level Measurement SITRANS LC00 Siemens AG 2011 Further designs Order code Please add "-Z" to Order No. and specify Order code(s). Insertion length, specify in plain text: Y01: to mm Y01 Active shield length, specify in plain text Y02 [min. length is 0 mm (2 inch)]: Y02: to mm Stainless steel tag [69 x 0 mm (2.71 x 1.97 inch)]: Y1 Measuring-point number/identification (max. 16 characters) specify in plain text Acceptance test certificate: Manufacturer's test C11 certificate M to DIN 30, Part 18 and ISO 9000 Inspection Certificate Type 3.1 per EN 10204 C12 Operating Instructions Order No. English C) 7ML1998-GE03 French C) 7ML1998-GE12 Spanish C) 7ML1998-GE21 German 7ML1998-GE33 Note: The Operating Instructions should be ordered as a separate line item on the order. This device is shipped with the Siemens Milltronics manual CD containing the complete ATEX Quick Start and Operating Instructions library. Accessories Transmitter, MSP 2002-1, 330 PF C) 7ML1830-1JP Transmitter, MSP 2002-2, 3300 PF C) 7ML1830-1JQ Transmitter, MSP 2002-3, 6600 PF (used with conductive fluids and probe lengths >10000 mm) D) 7ML1830-1JR SITRANS RD100 Remote display - see Chapter 8 SITRANS RD200 Remote display - see Chapter 8 SITRANS RD00 web, datalogging, alarming, K) 7ML70- ethernet, and modem support for instrumentation - 1AA00-0 see Chapter 8 Transmitters not suitable for Intrinsically Safe application (ATEX II 1G EEx ia IIC T4 or CSA/FM Class 1 Div 1 Grp A,B,C and D) C) Subject to export regulations AL: N, ECCN: EAR99. D) Subject to export regulations AL: N, ECCN: EAR99H. K) Subject to export regulations AL: N, ECCN: A991X. Please contact ceg.smpi@siemens.com for special requests. /320 Siemens FI 01 2012

Siemens AG 2011 Level Measurement SITRANS LC00 Characteristic curves Pressure/Temperature Curve LC00 Cable Probes Threaded Process Connections (7ML13) Permitted Operating Pressures P 30 bar (43 psi) 20 bar (290 psi) atmospheric -1 bar (-14. psi) -10 ºC (-238 ºF) -100 ºC (-148 ºF) 10 bar (14 psi) -40 ºF 14 ºF (-40 ºC) (-10 ºC) -0 ºC (-8 ºF) -29 ºC (-20 ºF) Example: Permitted operating pressure = 10 bar (14 psi) at 7 C 100 ºF (38 ºC) 200 ºF (93 ºC) 0 ºC RT 0 ºC 100 ºC (32 ºF) (122 ºF) (212 ºF) 300 ºF (149 ºC) 10 ºC (302 ºF) 400 ºF (204 ºC) 200 ºC (392 ºF) 00 ºF (260 ºC) 20 ºC (482 ºF) Permitted Operating Temperature T SITRANS LC00 Process Pressure/Temperature derating curves (7ML13) Siemens FI 01 2012 /321

Level Measurement SITRANS LC00 Siemens AG 2011 Pressure/Temperature Curve LC00 PFA Rod Probes Threaded Process Connections (7ML Permitted Operating Pressures P 10 bar (2,17 psi) 140 bar (2,030 psi) 130 bar (1,88 psi) 120 bar (1,740 psi) 110 bar (1,9 psi) 100 bar (1,40 psi) 90 bar (1,30 psi) 80 bar (1,160 psi) 70 bar (1,01 psi) 60 bar (870 psi) 0 bar (72 psi) 40 bar (80 psi) 30 bar (43 psi) 20 bar (290 psi) atmospheric -1 bar (-14. psi) -10 ºC (-238 ºF) -100 ºC (-148 ºF) 10 bar (14 psi) -40 ºF 14 ºF (-40 ºC) (-10 ºC) -0 ºC (-8 ºF) -29 ºC (-20 ºF) 100 ºF (38 ºC) 200 ºF (93 ºC) 0 ºC RT 0 ºC 100 ºC (32 ºF) (122 ºF) (212 ºF) 300 ºF (149 ºC) 10 ºC (302 ºF) 400 ºF (204 ºC) 200 ºC (392 ºF) 00 ºF (260 ºC) 20 ºC (482 ºF) Permitted Operating Temperature T SITRANS LC00 Process Pressure/Temperature derating curves (7ML /322 Siemens FI 01 2012

Siemens AG 2011 Level Measurement SITRANS LC00 Pressure/Temperature Curve LC00 Cable Probes ASME Flanged Process Connections (7ML13) Permitted Operating Pressures P 20 bar (290 psi) atmospheric -1 bar (-14. psi) -10 ºC (-238 ºF) -100 ºC (-148 ºF) 10 bar (14 psi) -40 ºF 14 ºF (-40 ºC) (-10 ºC) -0 ºC (-8 ºF) -29 ºC (-20 ºF) 100 ºF (38 ºC) 200 ºF (93 ºC) 0 ºC RT 0 ºC 100 ºC (32 ºF) (122 ºF) (212 ºF) 300 ºF (149 ºC) 10 ºC (302 ºF) 400 ºF (204 ºC) 200 ºC (392 ºF) 00 ºF (260 ºC) 20 ºC (482 ºF) 600 ºF (31 ºC) 300 ºC (72 ºF) 700 ºF (371 ºC) 30 ºC (662 ºF) ASME 10 lb 400 ºC (72 ºF) Permitted Operating Temperature T The curve denotes the minimum allowable flange class for the shaded area below. SITRANS LC00 Process Pressure/Temperature derating curves (7ML13) Siemens FI 01 2012 /323

Level Measurement SITRANS LC00 Siemens AG 2011 Pressure/Temperature Curve LC00 PFA Rod Probes ASME Flanged Process Connections (7ML1 and 7ML17) Permitted Operating Pressures P 10 bar (2,17 psi) 140 bar (2,030 psi) 130 bar (1,88 psi) 120 bar (1,740 psi) 110 bar (1,9 psi) 100 bar (1,40 psi) 90 bar (1,30 psi) 80 bar (1,160 psi) 70 bar (1,01 psi) 60 bar (870 psi) 0 bar (72 psi) ASME 600 lb 40 bar (80 psi) 30 bar (43 psi) ASME 300 lb 20 bar (290 psi) atmospheric -1 bar (-14. psi) -10 ºC (-238 ºF) -100 ºC (-148 ºF) 10 bar (14 psi) -40 ºF 14 ºF (-40 ºC) (-10 ºC) -0 ºC (-8 ºF) -29 ºC (-20 ºF) 100 ºF (38 ºC) 200 ºF (93 ºC) 0 ºC RT 0 ºC 100 ºC (32 ºF) (122 ºF) (212 ºF) 300 ºF (149 ºC) 10 ºC (302 ºF) 400 ºF (204 ºC) 200 ºC (392 ºF) 00 ºF (260 ºC) 20 ºC (482 ºF) 600 ºF (31 ºC) 300 ºC (72 ºF) 700 ºF (371 ºC) 30 ºC (662 ºF) ASME 10 lb 400 ºC (72 ºF) Permitted Operating Temperature T The curve denotes the minimum allowable flange class for the shaded area below. SITRANS LC00 Process Pressure/Temperature derating curves (7ML1 and 7ML17) /324 Siemens FI 01 2012

Siemens AG 2011 Level Measurement SITRANS LC00 Pressure/Temperature Curve LC00 Cable Probes EN Flanged Process Connections (7ML13) Permitted Operating Pressures P 20 bar (290 psi) atmospheric -1 bar (-14. psi) -10 ºC (-238 ºF) -100 ºC (-148 ºF) 10 bar (14 psi) -40 ºF 14 ºF (-40 ºC) (-10 ºC) -0 ºC (-8 ºF) -29 ºC (-20 ºF) 100 ºF (38 ºC) 200 ºF (93 ºC) 0 ºC RT 0 ºC 100 ºC (32 ºF) (122 ºF) (212 ºF) 300 ºF (149 ºC) 10 ºC (302 ºF) 400 ºF (204 ºC) 200 ºC (392 ºF) 00 ºF (260 ºC) 20 ºC (482 ºF) 600 ºF (31 ºC) 300 ºC (72 ºF) 700 ºF (371 ºC) 30 ºC (662 ºF) PN 16 400 ºC (72 ºF) Permitted Operating Temperature T The curve denotes the minimum allowable flange class for the shaded area below. SITRANS LC00 Process Pressure/Temperature derating curves (7ML13) Siemens FI 01 2012 /32

Level Measurement SITRANS LC00 Siemens AG 2011 Pressure/Temperature Curve LC00 PFA Rod Probes EN Flanged Process Connections (7ML1 and 7ML17) Permitted Operating Pressures P 10 bar (2,17 psi) 140 bar (2,030 psi) 130 bar (1,88 psi) 120 bar (1,740 psi) 110 bar (1,9 psi) 100 bar (1,40 psi) 90 bar (1,30 psi) 80 bar (1,160 psi) 70 bar (1,01 psi) 60 bar (870 psi) 0 bar (72 psi) 40 bar (80 psi) 30 bar (43 psi) 20 bar (290 psi) PN 40 atmospheric -1 bar (-14. psi) -10 ºC (-238 ºF) -100 ºC (-148 ºF) 10 bar (14 psi) -40 ºF 14 ºF (-40 ºC) (-10 ºC) -0 ºC (-8 ºF) -29 ºC (-20 ºF) 100 ºF (38 ºC) 200 ºF (93 ºC) 0 ºC RT 0 ºC 100 ºC (32 ºF) (122 ºF) (212 ºF) 300 ºF (149 ºC) 10 ºC (302 ºF) 400 ºF (204 ºC) 200 ºC (392 ºF) 00 ºF (260 ºC) 20 ºC (482 ºF) 600 ºF (31 ºC) 300 ºC (72 ºF) 700 ºF (371 ºC) 30 ºC (662 ºF) 400 ºC (72 ºF) PN 16 Permitted Operating Temperature T The curve denotes the minimum allowable flange class for the shaded area below. SITRANS LC00 Process Pressure/Temperature derating curves (7ML1 and 7ML17) /326 Siemens FI 01 2012

Siemens AG 2011 Level Measurement SITRANS LC00 Pressure/Temperature Curve LC00 Enamel Rod Probes ASME Flanged Process Connections (7ML1 and 7ML17) Permitted Operating Pressures P 360 bar (,366 psi) 340 bar (4,931 psi) 320 bar (4,641 psi) 300 bar (4,31 psi) 280 bar (4,061 psi) 260 bar (3,771 psi) 240 bar (3,481 psi) 220 bar (3,191 psi) 200 bar (2,900 psi) 180 bar (2,610 psi) 160 bar (2,320 psi) 140 bar (2,030 psi) 120 bar (1,740 psi) 100 bar (1,40 psi) 80 bar (1,160 psi) atmospheric -1 bar (-14. psi) -10 ºC (-238 ºF) -100 ºC (-148 ºF) 60 bar (870 psi) 40 bar (80 psi) 20 bar (290 psi) -40 ºF 14 ºF (-40 ºC) (-10 ºC) -0 ºC (-8 ºF) -29 ºC (-20 ºF) 100 ºF (38 ºC) 200 ºF (93 ºC) 0 ºC RT 0 ºC 100 ºC (32 ºF) (122 ºF) (212 ºF) 300 ºF (149 ºC) 10 ºC (302 ºF) 400 ºF (204 ºC) 200 ºC (392 ºF) 00 ºF (260 ºC) 20 ºC (482 ºF) 600 ºF (31 ºC) 300 ºC (72 ºF) ASME 10 lb 700 ºF (371 ºC) 30 ºC (662 ºF) ASME 600 lb ASME 300 lb 400 ºC (72 ºF) Permitted Operating Temperature T The curve denotes the minimum allowable flange class for the shaded area below. SITRANS LC00 Process Pressure/Temperature derating curves (7ML1 and 7ML17) Siemens FI 01 2012 /327

Level Measurement SITRANS LC00 Siemens AG 2011 Pressure/Temperature Curve LC00 Enamel Rod Probes EN Flanged Process Connections (7ML1 and 7ML17) Permitted Operating Pressures P 360 bar (,366 psi) 340 bar (4,931 psi) 320 bar (4,641 psi) 300 bar (4,31 psi) 280 bar (4,061 psi) 260 bar (3,771 psi) 240 bar (3,481 psi) 220 bar (3,191 psi) 200 bar (2,900 psi) 180 bar (2,610 psi) 160 bar (2,320 psi) 140 bar (2,030 psi) 120 bar (1,740 psi) 100 bar (1,40 psi) 80 bar (1,160 psi) 60 bar (870 psi) 40 bar (80 psi) atmospheric -1 bar (-14. psi) -10 ºC (-238 ºF) -100 ºC (-148 ºF) 20 bar (290 psi) -40 ºF 14 ºF 100 ºF 200 ºF 300 ºF 400 ºF 00 ºF 600 ºF 700 ºF (-40 ºC) (-10 ºC) (38 ºC) (93 ºC) (149 ºC) (204 ºC) (260 ºC) (31 ºC) (371 ºC) PN 16-0 ºC (-8 ºF) -29 ºC (-20 ºF) 0 ºC RT 0 ºC 100 ºC (32 ºF) (122 ºF) (212 ºF) 10 ºC (302 ºF) 200 ºC (392 ºF) 20 ºC (482 ºF) 300 ºC (72 ºF) 30 ºC (662 ºF) 400 ºC (72 ºF) PN 40 Permitted Operating Temperature T The curve denotes the minimum allowable flange class for the shaded area below. SITRANS LC00 Process Pressure/Temperature derating curves (7ML1 and 7ML17) /328 Siemens FI 01 2012

Siemens AG 2011 Level Measurement SITRANS LC00 Pressure/Temperature Curve LC00 Single Piece Flanged Rod Probes with PTFE facing EN Flanged Process Connections (7ML17) Permitted Operating Pressures P 80 bar (1,160 psi) 70 bar (1,01 psi) 60 bar (870 psi) 0 bar (72 psi) 40 bar (80 psi) 30 bar (43 psi) 20 bar (290 psi) PN 40 atmospheric -1 bar (-14. psi) -10 ºC (-238 ºF) -100 ºC (-148 ºF) 10 bar (14 psi) -40 ºF (-40 ºC) -0 ºC (-8 ºF) -29 ºC (-20 ºF) 14 ºF (-10 ºC) 100 ºF (38 ºC) 200 ºF (93 ºC) 0 ºC RT 0 ºC 100 ºC (32 ºF) (122 ºF) (212 ºF) 300 ºF (149 ºC) 10 ºC (302 ºF) 400 ºF (204 ºC) 200 ºC (392 ºF) 00 ºF (260 ºC) 20 ºC (482 ºF) 600 ºF (31 ºC) 300 ºC (72 ºF) 700 ºF (371 ºC) 30 ºC (662 ºF) 400 ºC (72 ºF) PN 16 Permitted Operating Temperature T The curve denotes the minimum allowable flange class for the shaded area below. SITRANS LC00 Process Pressure/Temperature derating curves (7ML17) Siemens FI 01 2012 /329

Level Measurement SITRANS LC00 Siemens AG 2011 Pressure/Temperature Curve LC00 Single Piece Flanged Rod Probes with PTFE facing ASME Flanged Process Connections (7ML17) Permitted Operating Pressures P 80 bar (1,160 psi) 70 bar (1,01 psi) 60 bar (870 psi) 0 bar (72 psi) ASME 600 lb 40 bar (80 psi) 30 bar (43 psi) 20 bar (290 psi) ASME 300 lb atmospheric -1 bar (-14. psi) -10 ºC (-238 ºF) -100 ºC (-148 ºF) 10 bar (14 psi) -40 ºF 14 ºF (-40 ºC) (-10 ºC) -0 ºC (-8 ºF) -29 ºC (-20 ºF) 100 ºF (38 ºC) 200 ºF (93 ºC) 0 ºC RT 0 ºC 100 ºC (32 ºF) (122 ºF) (212 ºF) 300 ºF (149 ºC) 10 ºC (302 ºF) 400 ºF (204 ºC) 200 ºC (392 ºF) 00 ºF (260 ºC) 20 ºC (482 ºF) 600 ºF (31 ºC) 300 ºC (72 ºF) 700 ºF (371 ºC) 30 ºC (662 ºF) ASME 10 lb 400 ºC (72 ºF) Permitted Operating Temperature T The curve denotes the minimum allowable flange class for the shaded area below. SITRANS LC00 Process Pressure/Temperature derating curves (7ML17) /330 Siemens FI 01 2012

Siemens AG 2011 Level Measurement SITRANS LC00 Dimensional drawings Cable version, non-insulated welded flange (7ML13) Cable version, insulated welded flange (7ML13) Transmitter/ electronics 20 (0.79) Option for mounting eye only available for PFA insulated cable Stainless steel cable Ø6 (0.24) Stainless steel weight Masuring length Y01 (insertion length) min. = 1000 (39.40) / max. = 3000 (1378) Extended cable version with rod sensor welded flange (7ML23) Stainless steel flexible tube Ø16 (0.63) 63 (2.48) 92 (3.62) Measuring length 92 (3.62) 20 (9.84) Ø32 (1.26) 20 (0.79) Y02 Inactive length Ø48 (1.88) Y01 (insertion length) min. = 000 (197) / max. = 3000 (1378) 20 (0.79) Mounting eye option PFA insulated probe Mounting eye Ø12 (0.47) Stainless steel weight Ø2 (0.98) Ø9 (0.3) Measuring length Extended cable version with rod sensor welded flange (7ML23) Stainless steel flexible tube Ø40 (1.7) Ø24 (0.94) Ø3 (1.37) 30 (13.78) 4 (2.12) Measuring length Y02 Inactive length Y01 (insertion length) min. = 1000 (39.40) / max. = 3000 (1378) Ø34. (1.36) Y01 (insertion length) min. = 000 (197) / max. = 3000 (1378) 1 (0.60) Ø34. (1.36) Mounting eye Ø2 (0.98) Note: Applicable for non-conductive media only. Cable can be shortened on site. Weight is included in measuring length. 2) Applicable for both liquids and solids. Cable cannot be shortened. Weight is not part of measuring length. 3) For Y02 lengths greater than 000 (197), cable is inactive and is not actively shielded. 4) Minimum length = 200 (7.87) ) Insertion length Y01 = Y02 + measuring length + 92 (3.62) 6) Insertion length Y01 = Y02 + measuring length + 1 (0.9) Inactive tip 100 (3.9) Ø9 (0.3) Mounting eye option Ø12 (0.47) 30 (13.78) 20 (0.79) SITRANS LC00 - Cable Versions, dimensions in mm (inch) Siemens FI 01 2012 /331

Level Measurement SITRANS LC00 Siemens AG 2011 Cable version, non-insulated Welded flange (7ML13) Cable version, insulated Welded flange (7ML13) 2) Transmitter/ electronics Option for mounting eye only available for PFA insulated cable Ø9 (0.3) Stainless steel cable Ø6 (0.24) Stainless steel weight 20 (9.84) Measuring length Y01 (insertion length) max. = 3000 (1378) PFA insulated probe Ø9 (0.3) Stainless steel weight Measuring length 30 (13.78) Y01 (insertion length) max. = 3000 (1378) Ø34. (1.36) Mounting eye Ø2 (0.98) Ø12 (0.47) 30 (13.78) 20 (0.79) Ø32 (1.26) Ø34. (1.36) Extended cable version with rod sensor Welded flange (7ML23) 3) Extended cable version with rod sensor Welded flange (7ML23) 3) Stainless steel flexible tube Ø16 (0.63) 63 (2.48) 92 (3.62) 4) Measuring length 92 (3.62) Y02 Inactive length Y01 (insertion length) min. = 000 (197) / max. = 3000 (1378) ) Ø48 (1.88) 20 (0.79) Mounting eye option Mounting eye Ø12 (0.47) Ø2 (0.98) Stainless steel flexible tube Ø40 (1.7) Ø24 (0.94) Ø3 (1.37) 4 (2.12) Y02 Inactive length 4) Measuring length Y01 (insertion length) min. = 000 (197) / max. = 3000 (1378) 6) 1 (0.60) Note: Applicable for non-conductive media only. Cable can be shortened on site. Weight is included in measuring length. 2) Applicable for both liquids and solids. Cable cannot be shortened. Weight is not part of measuring length. 3) For Y02 lengths greater than 000 mm (197"), cable is inactive and is not actively shielded. 4) Minimum length = 200 mm (7.87") ) Insertion length Y01 = Y02 + measuring length + 92 mm (3.62") 6) Insertion length Y01 = Y02 + measuring length + 1 mm (0.9") Inactive tip 100 (3.9) Mounting eye option SITRANS LC00 - Cable Versions, dimensions in mm (inch) /332 Siemens FI 01 2012

Siemens AG 2011 Level Measurement SITRANS LC00 Rod version Threaded (7ML Rod version with stilling well Threaded (7ML Remote electronics with mounting bracket option Threaded (7ML transmitter/ electronics 20 (8. 20 (8. 10 (6) PFA insulated probe Ø16 (0.63) or Ø24 (0.94) * = 30 (1.18) Inactive tip 20 (0.79) * measuring length Y02 Y01 (insertion length) min. = 200 (7.87) / max. = 300 (138), Ø16 (0.63) min. = 200 (7.87) / max. = 00 (216), Ø24 (0.94) Note: Minimum Y02 (active shield length) = 0 (1.96), minimum measuring length = 200 (7.87) stainless steel stilling well vent holes or optional slots PFA insulated probe Ø16 (0.63) or Ø24 (0.94) Ø3 (1.38) or Ø48 (1.89) Y02 * measuring length Y01 (insertion length) min. = 200 (7.87) / max. = 300 (138), Ø16 (0.63) min. = 200 (7.87) / max. = 00 (216), Ø24 (0.94) General Purpose approval only. Standard configuration (all versions) With explosion-proof seal option (all versions) stainless steel flexible tube 270 (10.6) 20 (8. M20: 160 (6.3) 1/2" NPT: 230 (9. With thermal isolator option (all versions) thermal isolator 430 (16.9) SITRANS LC00 - Rod Versions, dimensions in mm (inch) Siemens FI 01 2012 /333

Level Measurement SITRANS LC00 Siemens AG 2011 Rod version Welded flange (7ML Single piece flange (7ML17) Rod version with stilling well Welded flange (7ML Single piece flange (7ML17) Remote electronics with mounting bracket option Welded flange (7ML Single piece flange (7ML17) transmitter/ electronics PFA insulated probe measuring length Y02 2) Y01 (insertion length) 20 (8. min. = 200 (7.87) / max. = 300 (138), Ø16 (0.63) (Typical) min. = 200 (7.87) / max. = 00 (216), Ø24 (0.94) stainless steel stilling well vent holes or optional slots PFA insulated probe Ø16 (0.63) or Ø24 (0.94) measuring length Y01 (insertion length) min. = 200 (7.87) / max. = 300 (138), Ø16 (0.63) min. = 200 (7.87) / max. = 00 (216), Ø24 (0.94) 2) stainless steel flexible tube General Purpose approval only. PTFE flange facing option Single piece flange only (7ML17) raised face flange PTFE flange facing Ø16 (0.63) or Ø24 (0.94) Ø3 (1.38) or Ø48 (1.89) No stilling well or enamel probe available with this option. * = 30 (1.18) Inactive tip * * Y02 10 (6) Standard configuration (all versions) With explosion-proof seal option (all versions) 270 (10.6) 20 (8. M20: 160 (6.3) 1/2" NPT: 230 (9. With thermal isolator option (all versions) thermal isolator 430 (16.9) Flange Class ASME 10/300 ASME 600/900 PN16/2/40/64 Flange Facing (raised face) PTFE facing (additional) Facing thickness 2 (0.08) 7 (0.28) 2 (0.08) 2 (0.08) Notes: Minimum Y02 (active shield length) = 0 (1.96), minimum measuring length = 200 (7.87) 2) Insertion length does not include any raised face/gasket face dimension (see Flange Facing table above). SITRANS LC00 - Rod Versions, dimensions in mm (inch) /334 Siemens FI 01 2012

Siemens AG 2011 Level Measurement SITRANS LC00 Schematics Ground lug Instrument system ground Measuring signal (mini-coaxial cable) Protective label Solid state switch relay (any polarity) 4-20 ma Current loop connection (any polarity) Ground connection point for instrument system SITRANS LC00 connections Siemens FI 01 2012 /33

Level Measurement SITRANS LC300/LC00 Specials Siemens AG 2011 Selection and ordering data LC300 and LC00 Specials. See note 1. LC300 and LC00 Specials. See note 1. Order No. Order No. LC300 Cable Extensions, 316L stainless steel LC300 Weight Kit, 316L stainless steel Kit, Stainless steel cable extension, 1 m, adjustable by customer Kit, Stainless steel cable extension, 3 m, adjustable by customer AE01163688 AE01163689 Kit, Spare stainless steel weight. To be used in any cable version of CLS300, or stainless steel cable version of LC300 LC00 Gasket (IP6), Silicone AE01163727 Kit, Stainless steel cable extension, m, adjustable by customer AE01163690 Kit, Stainless steel cable extension, 10 m, adjustable by customer AE01163691 Kit, Stainless steel cable extension, 1 m, adjustable by customer AE01163693 Kit, Stainless steel cable extension, 20 m, adjustable by customer LC300 Cable Extensions, 316 stainless steel with PFA coating AE0116369 Spare gasket, LC00 enclosure version, IP6 J) LC00 Blind Lid AE01163728 Kit, PFA cable extension, 1 m Kit, PFA cable extension, 3 m AE01163709 AE01163710 Spare LC00 aluminum blind lid LC00 Mounting Eye AE01163729 Kit, PFA cable extension, m AE01163711 Kit, PFA cable extension, 10 m AE01163712 Kit, PFA cable extension, 1 m AE01163713 Kit, PFA cable extension, 20 m AE01163714 LC300 Mounting Eye Spare mounting eye (PFA cable version only) AE01163717 LC00 Mounting Bracket Spare mounting eye (LC300 PFA versions only) AE01163717 Spare mounting bracket AE01163730 LC00 Sanitary Versions See note 2. J) Subject to export regulations AL: 91999, ECCN: EAR99. Note 1: Special flange sizes and facings are available. Please contact ceg.smpi@siemens.com for part number and pricing. Submit Application Questionnaire found on page /9. Note 2: Please contact ceg.smpi@siemens.com for part number and pricing. Submit Application Questionnaire found on page /9. Please contact ceg.smpi@siemens.com for special requests. /336 Siemens FI 01 2012