EMC and Durability Lab, HCL Technologies Ltd., #73-74, South Phase, Ambattur Industrial Estate, Chennai

Similar documents
Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

USB3.0 for Active Optical Cable

USB3.0 For Active Optical Cable SPECIFICATIONS

GB60S 60W Single Output General Purpose Series

USB3.0 For Active Optical Cable SPECIFICATIONS

PRODUCT SPECIFICATION OUTPUT CURRENT (A) OUTPUT CURRENT TOLERANCE ±7% ±7% ±10% ±10% ±7% 1.8. Units % % % Typ. Typ.

Test report. Type VRLTC load tap changer VRLTC 1500A Type test summary report

CAN and Serial Instrumentation

DC-DC CONVERTERS 2:1 INPUT RANGE, UP TO 2 WATTS MEDICAL APPLICATIONS MTWA2 SERIES

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

DC-DC CONVERTERS 4:1 WIDE INPUT RANGE UP TO 9 WATTS SINGLE AND DUAL OUTPUT, SIP PACKAGE SWB9 SERIES

Contents. 1 Introduction. 2 General Product Information. 3 General Test Requirements

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

Max. Output Power. Efficiency (1) 110Vac 220Vac. 450 ma 90 ~ 305 Vac 445 Vdc 200 W 92% EUC-200S045ST

Model Number Structure

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

SPECIFICATIONS UPS Triple Output 13.6VDC/213W, 48VDC/153W, 48VDC/39W

Environmental Lab Tour Lab Overview

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

ENVIRONMENTAL TESTING

C B. Operating up to 5000m altitude 5 year product warranty Models

BE SURE POWER IS DISCONNECTED PRIOR TO INSALLATION! FOLLOW NATIONAL, STATE, AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION!

Surface mounting, flush mounting, and DIN track mounting

STRIDER ESSENTIAL SERIES ST50F-ESB ST40F-ESB Power for everything you need

Output Voltage Range. Parameter Min. Typ. Max. Notes. Input Voltage 90 Vac Vac 127~300 Vdc

KEPCO Will Point You In The Right Direction!

CLIMATE. Climate and temperature chambers.

A21M. Introduction: Functional Overview: Key Protection & Control Functions:

Industrial Power Supplies

Time scale: from 0.05 s to 100 h Multi-function Plug-in for use with 96 series sockets. Relay + socket. Wiring diagram (without control signal)

YOUR PARTNER FOR IMPULSE EMC EMC PARTNER PRODUCT RANGES. Immunity Lightning Component Emission Automation

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

201A-9 INSTALLATION INSTRUCTIONS. Revision A1 Rapid City, SD, USA, 01/2010

Load (2) Single or Dual

PDL09-48 S 05 M Series Name Input Output Output Case Voltage Quantity Voltage Option PART NUMBER STRUCTURE

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

PDL03-48 S 05 W H Series Name Input Output Output Input Isolation Voltage Quantity Voltage Range Option PART NUMBER STRUCTURE

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

TRC ELECTRONICS, INC DC/DC Converter SIP Package 6W MEAN WELL SPBW06 & DPBW06 Series

SDS05-48 S 05 W H Series Name Input Output Output Input Isolation Voltage Quantity Voltage Range Option PART NUMBER STRUCTURE

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Switching Power Supplies

Qualification of DHS50A,100A to Railway applications. (General Standard EN50155) (Shock and Vibration Standard EN61373)

Notes: Note1: values at nominal input voltage and full load. 8.5VDC 5V 8V. Open, Efficiency vs. Input Voltage. Efficiency [%]

Three-Phase Soft Starters

DPX30-xxDxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

EMC TEST REPORT. For The. 3-Phase Power Supply. Model: TPS300024

DPX30-xxSxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; 3.3 to 28 VDC Single Output; 30 Watts Output Power

DPX30-xxWDxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

PRO POWER 2 0 A L I T H I U M B AT T E RY C H A R G E R M O D E L : P P - L B C V E R S I O N : V 1. 0

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

DPX30-xxWSxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; 3.3 to 28VDC Single Output 30 Watts Output Power

Technical specifications

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Safety Standards. Model Number:

DPX15-xxWDxx Dual Output: DC-DC Converter Module 9.5 ~ 36VDC, 18 ~ 75VDC input; ±5 to ±15 VDC Dual Output; 15 Watts Output Power

Security Plus Online Uninterruptible Power Supply

RDL06-48 S 05 W - M3 Series Name Input Output Output Input Operating ambient Voltage Quantity Voltage Range temperature PART NUMBER STRUCTURE

Power Blade Charger Users Guide

Actuator LA35. Data sheet LINAK.COM/TECHLINE

HAE S 05 - P HS Series Name Input Output Output Ctrl and Assembly Option Voltage Quantity Voltage Pin Options

24V TO 13.5V FIXED OUTPUT VOLTAGE CONVERTER

An Overview of Automotive EMC Standards & Emerging Requirements

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

ECP180 Series. Low 1 Profile. High Power Density. 2.0 by 4.0 Footprint. 120W Convection-cooled Rating. 180W Force Cooled Rating

CHASSIS MOUNT DC-DC CONVERTERS 4:1 WIDE INPUT RANGE, 150 WATTS RAILWAY APPLICATIONS FWB(D)150 SERIES*

ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c.

Test Report No.: SHHG BC Date: JAN.31,2013 Page: 1 of 12

Time scale: from 0.05s to 100h Multi-function Plug-in for use with 90.02, 90.03, and sockets

Very high efficiency up to 93% Adjustable output voltage

3-Phase Military AC-DC Power Supply 3-Phase, VrmsL-L

Note1: Typical values at nominal input voltage and full load. 39VDC. Efficiency vs. Input Voltage. Efficiency [%]

Note1: Typical values at nominal input voltage and full load. 39VDC. Efficiency vs. Input Voltage. Efficiency [%]

Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS Technical brochure

BTE2000 / PTE2000 Series Precision stainless steel pressure transmitters

Linear Line Voltage LED Engine

RCD15W Series PART NUMBER STRUCTURE

Linear Line Voltage LED Engine

HAE S 05 W - P HS Series Name Input Output Output Input Ctrl and Assembly Option Voltage Quantity Voltage Range Pin Options

Generic Requirements for Outdoor Telephone Network Interface Devices (NIDs)

RP40- _FR/ Package (4) CTRL Logic (3)

HALF-BRICK DC-DC CONVERTERS 4:1 ULTRA WIDE INPUT RANGE 100 WATT RAILWAY APPLICATIONS HWB100 SERIES

2:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 87% Low Profile, 10.2mm Height Over Current Protection

Indoor Linear 50W Driver SI-CU WW

CPS2000 Cabinet Power System

Fisher 546 Electro Pneumatic Transducer

Series AM1P-Z 1 Watt DC-DC Converter

HAE S 05 - P TH HS PART NUMBER STRUCTURE Page 1. P-DUKE Technology Co., Ltd.

Typical efficiency up to 93 % Up to 4 kw power (max. 16 kw) Liquid or convection cooling. CAN bus serial interface. Adjustable output voltage

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

3. Input KJ: Thermocouple P: Platinum resistance thermometer G: Thermistor T: Thermocouple/platinum resistance thermometer (universal-input)

EMC TEST REPORT For. Shenzhen Better Technology Limited. High Voltage SMD LED Strip Light. Model No.: YH-HRF S-W

Hand-held Fundus Camera (Model :HFC) Operating Manual

High Current Thermal Fuse

EATON 9315 UPS 200 TO 300 KVA Specifications


Transcription:

Last Amended on - Page 1 of 10 I. EMI / EMC TESTS 1. IT Products / Household / Industrial / Medical / Network Telecommunications Equipment Radiated Emission Test (RE) CISPR11:2010 BSEN 55011:2010 CISPR22:2008 BSEN 55022 :2007, FCC Part 15 IEC 61000-6-3:2010 IEC 61000-6-4:2010 IEC 60255-25:2000 ICES 003, VCCI V-3 GR1089 Issue:04 9 khz to 18 GHz Electric Field ( In 10 m Semi- Anechoic chamber) Conducted Emission Test (CE) CISPR11:2010 BSEN 55011:2010 CISPR22:2008 BSEN 55022 :2010, FCC Part 15 IEC 61000-6-3:2010 IEC 61000-6-4:2010 IEC 60255-25:2000 ICES 003, VCCI V-3 150 khz to 30 MHz Power line: Single phase, Three Phase : 25A Signal port ISN 8 Wire-Cat 6- Gigabit Ethernet 8 Wire- Ethernet, 4 Wire- Ethernet, SDN 2 Wire- RJ 45 and RJ 11

Last Amended on - Page 2 of 10 Electrostatic Discharge Immunity Test (ESD) IEC 61000-4-2:2008 EN 61000-4-2:2009 IEC 60255-22-2:2008 IEC 61496-1:2012 Level: ±1kV to ± 30kV RF Radiated Susceptibility Test IEC 61000-4-3:2010 EN 61000-4-3:2010 IEC 60255-22-3 :2007 IEC 61496-1:2012 From 80 MHz to 3 GHz, Electric Field; Level: 20 V/m 80MHz to 1GHz @3m 1GHz to 3GHz @1 m

Last Amended on - Page 3 of 10 Electrical fast transient Immunity Test (EFT) IEC 61000-4-4:2012 EN 61000-4-4:2012 IEC 60255-26:2008 IEC 60255-22-4:2008 IEC 61496-1:2012 Level: +/-0.5 to +/-4.4kV Single phase:16a Three Phase: 32A 2. IT Products/ Household/ Industrial/ Medical Surge Immunity Test (1.2/50µS Lightning Surge) IEC 61000-4-5:2005 EN 61000-4-5:2006 IEC 60255-26:2008 IEC 60255-22-5:2008 IEC 61496-1:2012 Level: +/- 0.5 to+/- 6 kv Single phase:16a Three Phase: 32A

Last Amended on - Page 4 of 10 Conducted RF Susceptibility Test IEC 61000-4-6:2008 EN 61000-4-6:2009 IEC 60255-26:2008 IEC 60255-22-6:2001 IEC 61496-1:2012 Magnetic field Immunity test IEC 61000-4-8: 2009 EN 61000-4-8:2010 From : 150 khz to 80 MHz, Level : 10 V (rms) 1 to100a/m Continuous 300 A/m to1000 A/m, 1secs to 3 secs

Last Amended on - Page 5 of 10 Voltage dips & interrupts Immunity Test IEC 61000-4-11: 2004 EN 61000-4-11: 2004 Single phase: 16A Three Phase : 32A Harmonic Current emission IEC 61496-1:2012 IEC 61000-3-2: 2009 EN 61000-3-2: 2009 Flicker IEC 61000-3-3: 2008 EN 61000-3-3: 2008 Upto 40th Harmonic Single phase :16A Three Phase : 32A Frequency : 50 Hz

Last Amended on - Page 6 of 10 II. ENVIRONMENTAL TESTS 3. Electrical & Electronic items Cold (Low Temperature) IS 9000 part II -1977 MIL STD 810G-2008 SAE J1455-2012 JSS 50101-1996 GR-63 :2006 ETSI-300 019-2 -1 :2000 ETSI-300 019-2 -2 :1994 IEC 60068-2-1:2007 Ambient to -65 C to ambient Average rate of change of Temperature: 0.1 to 5 C/Minute Dry Heat ( High Temperature) IS 9000 Part III -1977 IEC 60068-2-2:2007 including Amend 1&2 SAE J1455-2012, JSS 50101-1996 GR-63 :2006 ETSI-300 019-2 - 1 : 2000 ETSI-300 019-2 - 2 : 1994 Ambient to 300 C Average rate of change of Temperature: 0.1 to 5 C/Minute

Last Amended on - Page 7 of 10 Change of Temperature IS 9000 Part XIV -1988 IEC 60068-2-14:2009 SAE J1455-2012, GR-63 :2006 ETSI-300 019-2 - 1 : 2000 ETSI-300 019-2 - 2 :1994-65 C to 180 C; Average rate of change of Temperature: 0.1 to 5 C / Minute Temperature Shock / Rapid change of Temperature with Prescribed time of transfer IS 9000 Part XIV- 1988 IEC 60068-2-14: 2009 SAE J1455-2012 JSS 55555:2000 Minimum Temperature : - 65 C, Maximum Temperature: +150 C Damp Heat (Steady State) IS 9000 Part IV 2008 MIL STD 810G-2008 JSS 50101-1996, GR-63 :2006 ETSI-300 019-2 - 1 :2000 ETSI-300 019-2 - 2 :1994 Temperature range: 25 C to 85 C, Humidity range: 10% to 97% RH.

Last Amended on - Page 8 of 10 IEC 60068-2-67-1995 IEC 60068-2-78-2012 Damp Heat (Cyclic) IS 9000 Part V, 1981 IEC 60068-2-30:2005 ASTM D2247-2011 JSS 50101-1996 ETSI-300 019-2 - 1 : 2000 ETSI-300 019-2 - 2 : 1994 Salt Spray (Corrosion) IEC 60068-2-11:1981 IEC 60068-2-52:1996 IS 9000 Part XI: 1983 ASTM B117-2003 NEMA -250 : 2008 Temperature range: 25 C to 85 C, Humidity range: 10% to 97% RH. Temperature: Ambient to 50 C Max, Sodium Chloride Concentration: 5%

Last Amended on - Page 9 of 10 Composite Temperature & Humidity IS 9000 Part VI,1978 IEC60068-38:1974 Temperature range: 25 C to 85 C, Humidity range: 10% to 97 % RH. Vibration IEC 60068-2-6:2007 IS 9000 Part VIII 1981 IEC 60255-21-1:1988 JSS 50101-1996 GR-63 :2006 IEC 60068-2-64:2008 ETSI-300 019-2 -1 :2000 ETSI-300 019-2 -2 :1994 Freq: 5Hz to 2 khz Maximum Acceleration: 80 g (2000kgf) Single axes and Three axes test

Last Amended on - Page 10 of 10 Shock IEC 60068-2-27:2008 IS 9000 Part VII:1988 IEC60255-21-2:1988 JSS 50101-1996 ETSI-300 019-2 -1 :2000 ETSI-300 019-2 -2 :1994 IEC 60068-2-29:1987 Acceleration Pulse width 10g-16ms 20g-6-11 ms 30g-6ms 40g-6ms (2000 kgf max) Water - IP X1 to IP X6 Degree of Protection provided by enclosures Dust - IP 1X to IP 6X Degree of Protection provided by enclosures IEC 60529-2001 IEC 60068-2-18:2000 IEC 60529-2001 IEC 60068-2-68:1994 Qualitative Test Qualitative Test Low Air Pressure Altitude IS 9000 Part Xiii :1988 JSS 50101-1996 GR-63 :2006 Atmosphere to 100 mbar -X-X-X-X-X-X-X-X-X-X-X-X-X-X-