Countum Group Metering Solutions Flowmeters The Satam range is used for the custody transfer measurement of liquid hydrocarbons, liquid gas and liquid chemicals. Consisting of four distinct families, the range is able to meet the needs of most industrial metering applications. Areas of activity Oil depots Metering for road tankers Aviation Transport via pipeline FPSO Content Positive Displacement meter Coriolis mass Turbine Ultrasonic
Positive Displacement meter The SATAM Positive Displacement meter (PD meter) is a system with freely-moving blades used to measure "white" petroleum products such as fuels, bio-fuels and refined liquid hydrocarbons. Its simple design using only two pairs of blades and one moving rotor makes it exceptionally robust and allows the user to make significant savings on maintenance costs. ZC17 Sectors of application Key points Oil depots For product reception and loading stations for trucks, wagons and ships Hydrocarbon transportation Distribution of fuel oil or fuel by road tanker Aircraft refuelling Aircraft dispensers and aircraft fuelling tankers Army Depot supplies and loading of trucks Transport companies Refuelling of locomotives, trucks and public transport coaches Marine applications Refuelling of ships Mining sites Refuelling of trucks or site machinery > Reduced pressure loss 0,3 to 0.5 bar at maximum flow rate > Low maintenance costs Simple and robust design with mechanical components interchangeable between the different models > Stability of measurements Accuracy of measurement guaranteed over a period of many years without any drift in the calibration curve > Modular design Wide range of accessories for performing customized measurement applications > Robust construction Flowmeter manifold separated from measurement chamber to eliminate any possible influence of external mechanical stresses on measurement. Few moving parts 2
Positive Displacement meter Positive Displacement meter ZC17 Model ZC17 12 ZC17 24 ZC17 48 ZC17 80 ZC17 150 ZC17 250 ZC17 330 Max. Flowrate Min. Flowrate Application (m3/h /LPM/USGPM) (m3/h /LPM/USGPM) 12/200/53 24/400/105 48/800/210 80/1333/360 150/2500/660 250/4166/1100 330/5500/1453 1.2/20/5.3 2.4/40/10.5 4.8/80/21 8/133/36 15/250/66 25/416/110 33/550/145 Multi-product metering Connections Flanges ASA150 2 2 2 3 4 6 8 Flanges TW TW1 TW3 Materials Manifold Aluminium Steel or Aluminum Steel Casing Aluminium Ductile iron or Ni resist iron Front and back flanges Rotor Blades Gaskets Nickel steel Aluminium Graphite Viton (option nitrile) Operating conditions Pressure 0 to 10 bar / 0 to 150 PSI Viscosity Liquid temperature Ambient temperature Pressure drop Max. : 800 mpa.s -10 C (14 F) to +80 C (176 F) Contact us for higher or lower temperatures -20 C (-4 F) to +55 C (131 F) Contact us for higher or lower temperatures Max 0,5 bar Internal construction Cyclic volume (litres/usg) 0,33/0.08 0,40/0.10 0,80/0.21 2,27/0.6 4,54/1.2 6,82/1.8 9.09/2.4 Metrological performance Accuracy <± 0,15% / Option <± 0,1% / For 10 : 1 measuring range Mass repeatability <± 0,02% Installation Straight inlet and outlet sections Not necessary Custody transfer approval EC Evaluation Certificate N LNE-11052 - Dimensions (mm) and weight Model ZC17 12 ZC17 24 ZC17 48 ZC17 80 ZC17 150 ZC17 250 ZC17 330 Distance between flanges 180 180 180 356 432 400 400 Width 290 290 290 356 432 400 400 Depth with mechan.register with pulser 220 186 220 186 246 266 365 272 492 399 620 526 746 653 Height with mechan.register with pulser 368 260 406 260 406 260 502 502 521 521 568 568 625 625 Weight (kg) 18 22 26 75 95 155 200 Flanges positions (flanges ASA150) PH1, PH2 PH1, PH2 PH1, PH2, PV1, PV2, PV3, PV4 PH1, PH2 (flanges TW) - - - 2 PV5 to PV10 PV5, PV6 - - 3
Coriolis mass flow meter The Satam mass is used to measure the mass and density of viscous products such as heavy fuel oil, engine oil, bitumen or crude oil. Its excellent pressure resistance qualities combined with its rugged design without any moving mechanical parts means it is capable of providing reliable and accurate measurements for liquid gases such as LPG. MFMU Sectors of application Key points Oil depots For product reception and at loading stations for trucks, wagons and ships Oil production Metering for transfers of products via pipeline Marine applications Loading and unloading of tankers Refineries Internal metering and control of manufacturing processes Fuel storage Metering of heavy fuel oil at mixer intake > Direct measurement of mass Direct measurement without any correction for temperature or viscosity > Reliability of measurements Insensitivity to vibrations and to piping forces due to its robust and stable measuring system > Flexibility of installation Patented construction allowing the system to be supported by its own housing or on the inlet and outlet pipes > Low maintenance costs Simple and robust design without any moving mechanical parts > Direct measurement of density Identification of liquid being measured and detection of any change of product 4
Coriolis mass flow meter Positive Displacement meter ZC17 Model 015 025 040 050 080 100 150 200 250 300 Maximum flow rate @ 1bar, 1cP, 1kg/dm 3 Minimum flow rate Applications (t/h) (kg/mn) (t/h) (kg/mn) Single and multi-product metering - Measurement of density Connection - Flanges Pressure class 150 Ibs RF (standard), 300 Ibs, 600 Ibs, 900 Ibs RF & RTJ (optional) Diameter (inches) Materials Measurement tube 316 L stainless steel Secondary containment and flanges 304 & ST37.2 stainless steel Operating conditions Pressure 0 to 63 bar Viscosity Liquid temperature Unrestricted Density 20 to 2000 kg/m 3-40 to + 150 C (compact version) -40 to +260 C (remote version) Ambient temperature -40 to + 60 C Pressure drop 1 bar (at maximum flowrate, 1mPa.s, 1 kg/dm 3 ) Internal construction Measurement tube Dual tube Measurement converter Compact or remote installation Metrological performances Mass accuracy <±0.1% + zero stability (liquids and liquefied gases) <±0.5% + zero stability (gases) Mass repeatability <±0.025% + zero stability Density accuracy <±0.005 g/cm3 / <±0.002 g/cm 3 after field calibration Temperature accuracy <±0.5 C Zero stability (kg/h) 1.2 3 6 8 12 20 46 70 150 220 Installation Straight inlet and outlet sections Not necessary Protection class IP 67, equivalent to NEMA 6 Ex approval II (1) 2G EEx d e [ia] IIC/IIB T6-T3 or II (1) 2G EEx d [ia] IIC/IIB T6-T3 Model 015 025 040 050 080 100 150 200 250 300 Dimensions (mm) Weight (kg) A B C 5. 25 20 55 74 118 200 460 700 1350 1900 88 333 917 1233 1967 3333 7667 11667 22500 31667 0.26 1 2.75 3.7 5.9 10 23 35 67.5 95 4.5 16.5 46 68.3 98.3 166 383 583 1125 1583 1 2 3 3 3 4 6 6 8 10 515 632 770 1024 1196 1358 1732 2198 2284 2925 497 562 630 1112 1312 1332 1662 1822 1962 1967 148 200 255 615 800 815 1070 1210 1300 1400 7 15 29 140 200 250 470 750 850 900 5
Turbine The Satam turbine is primarily used for high-capacity metering. Its 400 mm measurement tube can accurately measure at flowrates of over 4000 m 3 /h. Its excellent pressure and temperature resistance qualities means it is capable of providing reliable and accurate measurements for liquid gases such as LPG, as well as for cryogenic liquids. LM TM The LM and TM models come fitted with a two-bladed helical rotor. This construction ensures low sensitivity to variations in viscosity. Sectors of application Key points Marine applications Loading and unloading of tankers Oil production Metering for transfers of crude oil and condensate via pipeline Oil depots For product reception and at loading stations for wagons and ships Refineries Internal metering and control of manufacturing processes > Low maintenance costs Simple and robust design with interchangeable mechanical components > Stability of measurements Not sensitive to variations in pressure. Integrated flow straightener > Wide range of uses Available for liquids from 5 to 4000 m3/h 6
Turbine Positive Displacement meter ZC17 Model LM TM Flow rate 3 to 300 m 3 /h 15 to 4000 m3/h 13 to 1320 USGPM 66 to 17 600 USGPM Application Single and multi-product Single and multi-product Connection - Flanges Pressure class ANSI 150 ANSI 300 ANSI 150 to ANSI600 Diameter 2" to 4 3 to 16 Materials Measurement tube & flanges Carbon steel A106 (flanges) et A105 (measurement tube) / Stainless steel 316L Bearings Graphite, tungsten carbid Tungsten carbide Turbine rotor Aluminium / Titanium (optional) Light alloy (standard) / Stainless steel (option) / Titanium (option) Operating conditions Pressure 0 to 40 bar 0 to 63 bar Viscosity 0,1 to 15 mpa.s 0,1 to 120 mpa.s Liquid temperature without preamplifier -40 to +180 C -40 to +80 C Liquid temperature with preamplifier -20 to 80 C -40 to +80 C Pressure drop (1 mpa.s, Qmax) < 1 bar < 0.2 bar Internal construction Turbine rotor Helical twin-blade Helical twin-blade Pulser 2 1, 2 (standard) or 3 Preamplifier Optional Included Measurement chamber Removable Removable Metrological performance Volume accuracy < ± 0.15% Repeatability < ± 0.02% Installation Straight sections Inlet 0 DN / Outlet 0 DN Inlet 10 DN / Outlet 5 DN Protection class IP65 IP66 EX approval EEx ia IIC T6 and EEx d ia II C T6 ATEX II 2G, Ex d IIC T6 Measuring range LM model TM model Nominal diameter Min. flowrate Max. flowrate Min. flowrate Max. flowrate m 3 /h USGPM m 3 /h USGPM m 3 /h USGPM m 3 /h USGPM 2 3 13,2 30 132 - - - - 3 5 22 50 220 15 66 150 660 4 30 132 300 1320 30 132 300 1320 6 - - 60 264 600 2641 8 - - 120 528 1200 5283 10 - - 200 880 2000 8805 12 - - 300 1320 3000 13208 14 - - 16 - - 400 1761 4000 17611 7
Ultrasonic The Satam ultrasonic is used for measuring refined petroleum liquids. It is capable of measuring high-pressure fluids such as LPG or any other liquid gas. Its measurement tube without any intrusive elements or moving mechanical parts results in very little pressure drop and nearly no maintenance costs at all. Because of the measurement method used, ultrasonic s are available in diameters of up to 40 inches and provide exceptional accuracy of measurement. UFM III Sectors of application Key points Transport of petroleum products via pipeline Metering stations, leak detection Oil depots For product reception and at loading stations for wagons and ships Marine applications Loading and unloading of tankers Chemical industry Metering stations for non-corrosive liquids > Minimum pressure drop Measurement tube of same diameter as the flanges No intrusive element > Low maintenance costs Totally static measurement system No need for filtering > Exceptional reliable measurements Three-channel redundant configuration for measurement validation > Easy installation Bi-directional measurement Reduced weight in a compact design 8
Ultrasonic Model UFM III Flow rate 7 to 29 200 m 3 /h / 30 to 128 550 USGPM Application Single-product metering Connection - Flanges Pressure class 150lbs RF (standard), 300lbs, 600lbs, 900lbs RF & RTJ (optional) Diameter 2 to 40 Material Flanges, measurement tube, housing 316L stainless steel (other materials available on request) Operating conditions Operating pressure 0 to 63 bar Liquid temperature +25 to +140 C Ambient temperature -40 to +70 C Viscosity 0,1 to 10 mpa.s Pressure loss (1 cst, Qmax) < 0.1 bar Internal construction Ultrasound transmitters Windows incorporated into wall of measurement tube Measurement lines 3 parallel channels Metrological performance Measured parameter Actual volume Volume accuracy < ± 0.15% Repeatability < ± 0.02% Installation Straight sections Inlet 10 DN / Outlet 5 DN Protection class IP 66, equivalent to NEMA 4/4X/6 to IEC 529 EX approval EEx d [ib] II C T6 and EEx d e [ib] II C T6 Measuring range Nominal diameter Measuring range Weight and dimensions Min. flowrate Max. flowrate a Di W T Weight (m 3 /h) (m 3 /h) (mm) (mm) (mm) (mm) (kg) 2 7 73 290 49,2 150 345 14 3 16 164 330 73 200 380 26 4 29 292 380 97,2 220 412 33 6 66 657 440 154,1 270 466 45 8 117 1167 600 202,7 370 523 72 10 182 1824 640 254,4 420 582 105 12 263 2627 710 304,7 470 645 145 14 358 3575 770 336,5 500 687 179 16 467 4670 830 387,3 550 744 221 18 591 5910 900 438,1 600 788 256 20 730 7297 950 484 650 845 335 24 1051 10507 28 1430 14301 32 1868 18679 36 2364 23641 40 2919 29196 9
Satam meters for oil transport chain Oil transport chain PD meter Mass Turbine Ultrasonic Metering station for crude oil on pipeline Loading and unloading station for crude oil tankers FPSO Loading and unloading station for crude oil tanker wagons Refining and intermediary storage Road tanker loading station Delivery of domestic fuel oil by road tanker Aircraft refuelling 10
Flowmeter selection table By liquid Type of liquid PD meter Mass Turbine Ultrasonic Premium grade fuel, gasoline Ethanol Diesel Fatty Acid Methyl Ester (FAME) Kerosene Bio-diesel E5...E85 Heavy fuel oil Bitumen Pitch LPG LNG Light crude oils Condensates Industrial oils By application Type of application PD meter Mass Turbine Ultrasonic Truck loading station Wagon loading/unloading station Tanker loading/unloading station Aircraft refuelling On-board metering for road tankers Preparation and metering of bio-fuels Metering for light crude oil on pipeline Metering for condensate on pipeline Multi-product metering on pipeline Product identification on multi-product pipeline Control of mixer flowrate for preparation of maritime fuel oils : Ideally suited : Suitable subject to certain conditions 11
Countum Group Metering Solutions W o r l d w i d e L o c a t i o n C h a r t Headquarters & Sales Department PARIS NORD II Bat. le Gauguin - 47 allée des Impressionnistes BP 85012 Villepinte 95931 Roissy CDG Cedex FRANCE Tél. : +33 (0)1 48 63 02 11 Fax : +33 (0)1 49 38 41 01 E-mail : sales@satam.eu Manufacturing facility Avenue de Verdun - BP 129 14700 Falaise FRANCE Tél. : +33 (0)2 31 41 41 41 Fax : +33 (0)2 31 40 75 61 Le Havre Falaise Reims Paris-Villepinte Issoudun Bordeaux Headquarters Manufacturing facility Representative office Agent As Satam regularly improves its products to ever better respond to evolving market and regulatory requirements, it reserves the right to change any of the specifications of these products, and this without prior notice. www.satam.eu B042-GB-REV2-07/14-Marketing Satam - Design & Printing : TACTIC IMPRESSIONS