HYDRAULIC VARIABLE PUMPS

HYDRA-PAC SYNCHRONOUS HYDRAULIC POWER UNIT

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

Vane Pumps. VMQ Series Vane Pumps For Industrial and Mobile Applications Displacements to 215 cm 3/ r (13.12 in 3 /r) Pressures to 260 bar (3800 psi)

D SERIES HYDRAULIC PUMP

Vickers 45. VMQ Series 30 Vane Pumps. Fixed Displacement, For Industrial and Mobile Applications (4.188)

How to Identify Fluid Ports and Connectors

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

How to Identify Fluid Ports and Connectors

Disc Valve Hydraulic Motors Series 4000

Vickers. Piston Motors. Inline Piston Motors. Fixed and Variable Displacement. Revised 5/99 691

Variable displacement axial piston pumps

Variable displacement axial piston pumps,

Engineering Data. Assembly Length. How to Determine Correct Assembly Length

High Pressure Gear Pumps & Motors Series PZG Pumps Series MZG Motors

Disc Valve Hydraulic Motors 2000 Series

HYDRAULIC MOTORS MLHH

» Feeding mechanism of robots and manipulators» Metal working machines» Textile machines» Machines for agriculture» Food industries

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

6000 Series Highlights

ZDM Positive Displacement Flow Meter User Instructions

Disc Valve Hydraulic Motors 4000 Compact Series

Hydraulic Pump Series F1plus Fixed Displacement

Spool Valve Hydraulic Motors. Spool Valve motors incorporate the proven orbit motor principle to provide high torque at low speeds.

6000 Series. Highlights C-5. Description With torque up to 15,000 in-lb and 40 gpm continuous, this motor is packed with power operates very smoothly.

Disc Valve Hydraulic Motors Series 6000

VINCKE HYDRAULIC PUMPS

OMP Hydraulic Motor Versions

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

Vickers. Vane Pumps. Double Thru-drive Vane Pumps. High speed, high pressure VQT Series for mobile equipment. Released 7/93

Check Type Prefill & Exhaust Valves

Hydraulic gear pumps and motors

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 851 / 0813 / E

Variable displacement axial piston pumps,

Solutions. ydraulics. We Manufacture. H y d r a u l i c s. Char-Lynn Hydraulic Motors: h y d r a u l i c s

FEATURES: APPLICATIONS:

Features: Applications: 12 standard sizes Pressures to 3625 PSI (250 Bar)

Series 20 Axial Piston Pumps. Technical Information

Series 20 Axial Piston Pumps. Technical Information

Solutions. We Manufacture. H y d r a u l i c s. Eaton Medium Duty Piston Pump. h y d r a u l i c s

S Series (103-) Highlights B-3. Description. Specifications

Vickers. Vane Pumps. V Series - Low Noise Vane Pumps High Performance Intravane Pumps For Industrial Applications.

Spool Valve Hydraulic Motors Series J

HYDRAULICS VINCKE HYDRAULIC PUMPS

VIS (Valve-In-Star) Hydraulic Motor

J Series (129-) Highlights

Technical Information for PVX Series Pumps

AXIAL PISTON MOTORS SHMF

Disc Valve Hydraulic Motors

Kawasaki Motors Corp., U.S.A. Precision Machinery Division HMB 325. Staffa Fixed Displacement Hydraulic Motor

SPIN-ON FILTERS & ELEMENTS

Kawasaki Motors Corp., U.S.A. Precision Machinery Division HMB 100. Staffa Fixed Displacement Hydraulic Motor

PVX-11 VANE PUMPS. See pages 12 thru 14 for PVX-11 dimensions. VARIABLE DISPLACEMENT, PRESSURE COMPENSATED PERFORMANCE SPECIFICATIONS

OMEW Hydraulic Motor Versions

Gear Motors. Series PGM Fixed Displacement Motors, Aluminium Designs

MINING FORESTRY MOBILE TRUCK AGRICULTURE MATERIAL HANDLING OPTIMUM

Variable Displacement Piston Pumps for Industrial Applications

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

Denison GOLD CUP Product Catalog Piston Pumps & Motors For Open & Closed Circuits

12AT/50AT Series. Spin-On Filters. Global Filtration Technology

VARIABLE DISPLACEMENT AXIAL PISTON PUMPS DVP SERIES

Axial Piston Pump Series PV Design 45 Variable Displacement. Catalogue HY /UK February 2007

F SERIES GEAR PUMP. 2 Muncie Power Products, Inc Muncie Power Products, Inc.

High Speed Hydraulic Motors. Catalog HY /NA zm16 zm17

W1500 SERIES HYDRAULIC PUMP

S Series (103-) Highlights

"A" Series Variable Displacement Piston Pumps Single Pump, Pressure Compensator Type

Kawasaki Motors Corp., U.S.A. Precision Machinery Division. Staffa Fixed Displacement Hydraulic Motor

Hydraulic Pump Series F1 Fixed Displacement

Eaton Char-Lynn Low Speed, High Torque Motors. Orbit motor

AXIAL PISTON PUMPS SHPV SECTIONAL VIEW

VARIABLE DISPLACEMENT AXIAL PISTON PUMPS DVP SERIES

Solutions. ydraulics. We Manufacture. H y d r a u l i c s. Char-Lynn Hydraulic Motors. h y d r a u l i c s. General Purpose Motors A Series

Available manual, pneumatic, and hydraulic spool control kits.

PVE 19 & 21 Piston Pumps

High Speed Hydraulic Motors

2FV2V Series Variable Priority Flow Dividers

Group 1 Gear Pumps Technical Information General Information

s Eaton Light Duty Hydrostatic h y Hydrostatic Transmissions Models 6, 7, and 11 Ball Piston Pumps Models 7 and 11 We Manufacture Solutions

AP212HP Cast Iron Gear Pumps

WP Series Hydraulic & Pneumatic Flow Monitors Illustrated Price List

W SERIES HYDRAULIC MOTORS. WM600 Flange Options

Global Gear Products. Brochure. SAE A-Aluminum (Group 2)

Fixed Displacement Radial Piston Hydraulic Motor Staffa, Series B

Ordering Code of 2PBA Pumps

SPECIAL HYDRAULIC MOTORS AND MOTOR-BRAKES

" " Series Variable Displacement Piston Pumps

Gear Pumps / Motors. Series PGP / PGM Fixed Displacement Pumps, Cast-Iron and Aluminium Designs

Axial Piston Fixed Motor A2FM

PV Series E, J, & L Piston Pump Installation Tips and Procedures

Valves. E Valves. Multiple Hydraulic System Applications

Transcription:

SPECIFICATIONS PF2000 Series Fixed Displacement s Also refer to "Checkball Installation and Operating Recommendations" Bulletin PSI.CB (dynexpumpinstallation.pdf) CONTACT INFORMATION USA Headquarters Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI 53072 A. Tel: 262-691-2222 FAX: 262-691-0312 E-mail: sales@dynexhydraulics.com Power Units & Systems Dynex/Rivett Inc. 54 Nickerson Road Ashland, MA 01721 A. Tel: 508-881-5110 FAX: 508-881-6849 E-mail: ashland@dynexhydraulics.com European Sales Dynex/Rivett Inc. Unit C5 Steel Close, Little End Road, Eaton Socon, Huntingdon, Cambs. PE19 8TT United Kingdom Tel: +44 (0) 1480 213980 FAX: +44 (0) 1480 405662 E-mail: sales@dynexhydraulics.co.uk Download Dynex Product Specifications! BROCHURE NOTES: Specifications shown were in effect when published. Since errors or omissions are possible, contact your sales representative or the sales department for the most current specifications before ordering. Dynex reserves the right to discontinue products or change designs at any time without incurring any obligation. DYNEX High Hydraulics Copyright Dynex/Rivett Inc. Bulletin dynexpespf2000specs-1204

PF2000 SERIES Specifications DESCRIPTION Fixed displacement checkball pumps, with bi-directional shaft rotation, provide constant direction of output flow regardless of the direction of drive shaft rotation. Mounting S.A.E. B 2-bolt pattern with 0.25 inch (6,4 mm) pilot engagement. Shaft Options Standard keyed shaft, 0.875 inch (22.22 mm) diameter; Optional spline shaft, 0.873/0.872 inch diameter standard S.A.E. 13 tooth, 16/32 D.P. 30 involute spline. Contact the sales department for model number. Outlet Port Options Standard pressure models have S.A.E. ports. High pressure models use either coned and threaded fittings (Autoclave Medium, Butech M/P or equivalent), or B.S.P. fittings (British Standard Pipe). Inlet Conditions s may require pressurized inlet conditions at higher speeds. Failure to meet minimum inlet requirements will result in slight flow reduction. Refer to the table. Seal Options Standard seals are Buna-N (Nitrile). Contact the sales department for other seal options. Weight (Mass) 30 lb (14 kg) S.A.E. Ports: at 1500 ➀ gpm L/min at 1800 ➀ Intermittent gpm L/min psi bar psi bar PF2007-2190 3.4 12,9 4.1 15,5 6000 420 6000 420 2000 2800 PF2008-2191 4.8 18,3 5.8 22,0 5000 350 6000 420 2000 2400 PF2009-2184 5.1 19,2 6.1 23,1 3000 210 4000 280 2000 2800 PF2012-2185 7.1 26,8 8.5 32,2 3000 210 4000 280 2000 2400 Coned and Threaded Outlet Port:➁ PF2007-2973 3.4 12,9 4.1 15,5 6000 420 10 000 700 1800 2800 B.S.P. Outlet Port:➂ PF2007-3055 3.4 12,9 4.1 15,5 6000 420 10 000 700 1800 2800 ➀ Output flow based on typical performance at rated pressure with pressurized inlet where required, as shown in the table below. ➁ High pressure outlet port uses Autoclave Medium, Butech M/P or equivalent fitting. ➂ Outlet port uses British Standard Pipe fitting. Minimum Inlet s ➀ Operating 2000 2400 2800 psi bar psi bar psi bar PF2007 0 0 3 0,2 5 0,4 PF2008 0 0 5 0,4 PF2009 0 0 3 0,2 5 0,4 PF2012 0 0 5 0,4 ➀ Values shown are based on fluid viscosity of 100 SUS (20 cst). Inlet pressures higher than 10 psig (0,7 bar) require a high-pressure shaft seal. SELECTION The Specifications table lists the most commonly used standard models with keyed shafts. Contact the sales department for models with spline shafts, optional seals and other extraordinary operating requirements. Checkball pumps are especially suited for applications susceptible to excessive pressure spikes. The intermittent pressures listed are the maximum pressures a pump can sustain for occasional, short periods of operation without appreciably reducing life expectancy. Fluid Guidelines See page 6 for Fluid Recommendations. Some pump models may require reduced operating pressures when using lowlubricity fluids. Because of the wide range of fluid characteristics, contact the sales department for a review of any application using non-petroleum based fluids. Split-Flow Provides Multiple Outlets PF2000 models with split-flow covers efficiently supply flows for multiple function circuits. Piston outputs are grouped together in the cover, with various piston flow splits available in this six-piston pump. Contact the sales department for Split-Flow options and availability. 2

PF3000 PF2000 SERIES, SERIES 10 DESIGN Typical Performance Curves Typical performance curves are based on 100 SUS (20 cst) mineral oil with pressurized inlet where required. Refer to the Minimum Inlet table on page 2. INSTALLATION All dimensions are shown in inches (millimeters in parentheses) and are nominal. See page 2 for optional spline shaft data. Refer to Bulletin PSI.CB for general installation and operating recommendations. The diameter of the pump cover and the location of the outlet port varies as shown, dependent on the model. The port location for high-pressure models is shown printed in gray. This port uses either a coned and threaded (Autoclave or Butech) fitting or a B.S.P. (British Standard Pipe) fitting. Refer to Outlet Port Configurations on page 7 and the Specifications table on page 2 for model numbers to specify port. 5.75 (146,0) SQUARE KEY.25 x.75 (6,4 x 19,0) 3.19 (81,0) 7.06 (179,3) INLET PORT NO. 16 S.A.E. OUTLET PORT 3/4 MEDIUM PRESSURE CONED AND THREADED,.750 14 N.P.S.M. THREADED (AUTOCLAVE, BUTECH M/P, OR EQUIVALENT); OR G 1/2 (B.S.P.) OUTLET PORT NO. 8 S.A.E. 3.00 (76,2).986 25,04.979 ( 24,87 ) 4.000 3.998 101,60 ( 101,55).875 22,22.874 ( 22,20 ) 3.01 (76,5) 2.52 (64,0) 5.00 (127,0) 6.88 (174,8).562 (14,27) 2 MOUNTING HOLES 1.63 (41,4).25 (6,4).63 (16,0) 9.31 (236,5) 9.37 HIGH PRESSURE (238,0) 4.88 (124,0) 5.31 HIGH PRESSURE (134,9) 5.69 (144,5) 3

PF2000 SERIES SPECIAL MOUNTING Specifications DESCRIPTION Fixed displacement checkball pumps, with bi-directional shaft rotation, provide constant direction of output flow regardless of the direction of drive shaft rotation. Mounting Special 4-bolt pattern. Refer to installation drawing. Shaft Available with 1.25 inch (31,75 mm) diameter keyed shaft. Outlet Port Options Available with S.A.E. or N.P.T.F. ports. Refer to the Specifications table. Inlet Conditions s may require pressurized inlet conditions at higher speeds. Failure to meet minimum inlet requirements will result in slight flow reduction. Refer to the table. Seal Options Standard seals are Buna-N (Nitrile). Contact the sales department for other seal options. Weight (Mass) 43 lb (20 kg) S.A.E. Ports: Minimum Inlet ➀ All PF2000 (Special Mounting) Operating 2000 2400 psi bar psi bar 0 0 5 0,4 ➀ Values shown are based on fluid viscosity of 100 SUS (20 cst). Inlet pressures higher than 10 psig (0,7 bar) require a high-pressure shaft seal. SELECTION at 1500 ➀ gpm L/min at 1800 ➀ The Specifications table lists the most commonly used standard models with keyed shafts. Contact the sales department for models with optional seals and other extraordinary operating requirements. Checkball pumps are especially suited for applications susceptible to excessive pressure spikes. The intermittent pressures listed are the maximum pressures a pump can sustain for occasional, short periods of operation without appreciably reducing life expectancy. Fluid Guidelines See page 6 for Fluid Recommendations. Some pump models may require reduced operating pressures when using lowlubricity fluids. Because of the wide range of fluid characteristics, contact the sales department for a review of any application using non-petroleum based fluids. Intermittent gpm L/min psi bar psi bar PF2006-1808 3.3 12,6 4.0 15,1 6000 420 8000 560 2000 2400 PF2008-1804 4.7 18,0 5.7 21,6 3000 210 5000 350 2000 2400 N.P.T.F. Ports: PF2006-1807 3.3 12,6 4.0 15,1 6000 420 8000 560 2000 2400 PF2008-1802 4.7 18,0 5.7 21,6 3000 210 5000 350 2000 2400 ➀ Output flow based on typical performance at rated pressure with pressurized inlet where required, as shown in the Minimum Inlet table. Split-Flow Provides Multiple Outlets These PF2000 Series pumps can efficiently supply flows for multiple function circuits. Split-Flow models are available with isolator valves installed into the pump, to separate one or more pistons from the main outlet. Up to six independent outlet flows are possible from this six-piston pump. When using isolator valves, high-pressure models are limited to a maximum pressure of 6000 psi (420 bar). Contact the sales department for Split-Flow model numbers. 4

PF2000 SERIES SPECIAL MOUNTING Typical Performance Curves Typical performance curves are based on 100 SUS (20 cst) mineral oil with pressurized inlet where required. Refer to the Minimum Inlet table on page 4. INSTALLATION All dimensions are shown in inches (millimeters in parentheses) and are nominal. These PF2000 Series models have a special 4-bolt mounting pattern shown below. Refer to Bulletin PSI.CB for general installation and operating recommendations. Refer to Outlet Port Configurations on page 7 and the Specifications table on page 4 for model numbers to specify ports. 4.375 (111,12) AMERICAN STANDARD NO. 1212 WOODRUFF KEY.375 x 1.50 (9,52 x 38,1) ( 31,707 ) 1.2486 31,714 1.2483.56 (14,2) INLET PORT NO.12 S.A.E. OR 3/4 N.P.T.F. 3.81 (96,8) OUTLET PORT NO.10 S.A.E. OR 1/2 N.P.T.F. 2.468 2.466 62,69 ( 62,64 ) 1.404 1.414 35,66 ( 35,92 ) 1.25 (31,75) 2.81 (71,4) 5.63 (143,0).531 (13,49) 4 MOUNTING HOLES 3.06 (77,7) 8.58 (217,9) 3.16 (80,3).38 (9,7) 4.19 (106,4) 5

FLUID GUIDELINES FLUID RECOMMENDATIONS Mineral Oil A high-grade premium petroleum-based fluid should be used to assure long component and system life. The fluid should have a combination of anti-wear, demulsibility, rust protection, oxidationresistant and foam-resistant properties. Special Fluids Various pump models are available for use with water-based fluids, diesel calibration fluids, phosphate ester fluids, machining coolant, brake fluid, various military fluids and other special fluids. PF4300 Series pumps are compatible with a variety of water-based fluids. These models, which are specifically rated for use with low-lubricity fluids. Some pump models may require reduced operating pressures when using lowlubricity fluids. Because of the wide range of fluid characteristics, contact the sales department for a review of any application using non-petroleum based fluids. Viscosity Specifications Using fluid with the correct viscosity range is critical to achieving long component life. Fluid conditions outside the Optimum range shown in the table may result in reduced pump output, requiring pressurized inlet conditions. For more information, contact the sales department. Hydraulic Fluid Viscosity ➀ Operating Minimum Start-up➁ Optimum SUS cst SUS cst SUS cst SUS cst Fixed Displacement s: PF500-10 52 8 1911 413 3706 800 98 to 324 20 to 70 PF1000-10 59 10 1911 413 3706 800 98 to 324 20 to 70 PF2000 59 10 1911 413 1911 413 98 to 324 20 to 70 PF2000 ➁ 34 2,3 1911 413 1911 413 98 to 324 20 to 70 PF3000-10 59 10 1911 413 3706 800 98 to 342 20 to 70 PF4000-30 34 2,3 1911 413 1911 413 98 to 324 20 to 70 PF4200-10 34 2,3 1911 413 1911 413 98 to 324 20 to 70 PF4300-11 31 1,5 927 200 927 200 PF6000 34 2,3 1911 413 1911 413 98 to 324 20 to 70 Mechanical Variable Delivery s: PV4000 34 2,3 1911 413 1911 413 98 to 324 20 to 70 PV6000 34 2,3 1911 413 1911 413 98 to 324 20 to 70 Hydraulic Variable Delivery s: PV6000 34 2,3 1911 413 1911 413 98 to 324 20 to 70 ➀ Fluid conditions outside the Optimum range may result in reduced output, requiring pressurized inlet conditions. Contact the sales department. ➁ with special mounting. MINIMUM FILTRATION LEVELS inlet: 150 µ nominal; or return line: 25 µ nominal. While finer filtration levels than these are desirable and will result in longer component life, restricting flow to the pump inlet should be avoided. Minimum recommended inlet conditions must be maintained. If a system component fails resulting in fluid contamination, it is important to drain and clean the reservoir, all lines, filter screens and all components. Refill with new fluid. INSTALLATION AND OPERATION Refer to separate Bulletin PSI.CB for general installation and operating recommendations. That brochure includes information on mounting, shaft loading, sizing inlet pipe and hose, air bleed procedures and initial start-up. Guidelines for maintenance, repair and trouble-shooting are also included. 6

OUTLET PORT CONFIGURATIONS PORT DESCRIPTIONS Dynex pumps are available with outlet ports suitable for use at various pressure ranges. Refer to the appropriate Specification Table or Typical Model Code to specify the required port. Contact the fitting manufacturer to ensure the selected fittings are rated for the maximum pump operating pressure. S.A.E. Straight Thread Ports O-RING Typical S.A.E. Straight Thread port connection COUPLING The Straight Thread connection (S.A.E. J1926/1) is sometimes referred to as an S.A.E. O-ring Boss, or ORB. The port consists of a machined spotface surface, a tapered seal cavity and a straight thread port. The fitting forms a seal by compressing the o-ring in the seal cavity with the underside of the flanged wrench flat. Some adjustable fittings, such as elbows and tees, use a locknut with a captive backup washer for compression. S.A.E. Straight Thread ports are not recommended for operation above 8000 psi (560 bar). Also, the maximum pressure of pumps with No. 12 S.A.E. outlet ports may be limited by the pressure rating of the available fitting. Contact the fitting manufacturer for ratings. Coned and Threaded Ports TUBING SLEEVE High-pressure pumps are available with coned and threaded outlet ports, which use Autoclave Medium, Butech M/P, or equivalent fittings. These fittings provide a metal-to-metal seal with an interference fit, not requiring an o-ring. The gland nut holds the sleeve and tubing against the cone surface. A weep hole, visible on the outside of the pump cover, acts as an indicator of any abnormal leakage caused by system conditions (i.e., excessive pressure). It allows any fluid which does leak past the sealing surfaces to escape, preventing pressure build-up and possible damage. British Standard Pipe Ports GLAND NUT Typical Coned and Threaded port connection COUPLING SEAL RING SHOULDER Typical port connection with British Standard Pipe (Parallel) fitting with shoulder WEEP HOLE High-pressure pumps are available with flat face ports with British Standard Pipe (B.S.P.) parallel threads (BS 2779 or ISO 228), ideal for use on some European applications. The fitting forms a seal by compressing a flat elastomer ring on a machined spotface surface. There are several sealing methods for these ports. The recommended fitting has a recessed seal cavity formed by a shoulder on the underside of the flanged wrench flat (Voss Peflex, Form B Shoulder Seal; or Parker Type E, EOlastic Seal; or equivalent). B.S.P. ports are not recommended for operation above 10 000 psi (700 bar). Contact the fitting manufacturer, to ensure the selected fittings are rated for the maximum pump operating pressure. S.A.E. 4-Bolt Flange Ports BOLTS O-RING Typical S.A.E. 4-Bolt Flange port connection FLANGE Flange connections are often used for higher flows requiring larger diameter tubing. The port consists of an unthreaded port with four bolt holes in a rectangular pattern on a machined face around the port (S.A.E. J518). A typical fitting consists of a flanged head with a welded tube and a captive flange with bolt holes. A seal is formed by an o-ring in the groove on the underside mounting surface of the flange head. As the flange bolts are alternately tightened, the o-ring is compressed between the flange head and the machined face on the pump. To make mounting easier in tight spaces a two-piece split-flange is often used. 7