OmegaAir Series Dedicated Outside Air Systems (DOAS) Engineering Guide

Similar documents
TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

WATER SOURCE HEAT PUMPS

TECHNICAL GUIDE GENERAL HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS

D M S 760 C01 A A 1 1

SINGLE PACKAGE AIR CONDITIONING WATER COOLED

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS

i Series Model SV Water Source Heat Pump 1/2 to 6 Ton

Product Data. Features/Benefits. Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 12 Nominal Tons

Precision Cooling For Business-Critical Continuity. Liebert CW. System Design Manual kW, 50 & 60Hz

CPC Commercial. 7½- to 12½-Ton Three-Phase. up to 11.5 EER. Cooling Capacity: 90, ,000 BTU/h. Packaged Air Conditioners

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units

i Series Model SV Water Source Heat Pump 1/2 to 6 Ton

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH

24CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V)

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

SCROLL - AIR COOLED PACKAGED & SPLIT SYSTEM ICE CHILLERS

engineering guide Air-Cooled Self-Contained Units

36CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

PCB COMMERCIAL SERIES

Q6SP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

CFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh

Package Air Conditioners

Product Data. Features/Benefits. OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A)

CPC Commercial. 15- & 20-Ton, Three-Phase Packaged Air Conditioner. 20-Ton Cooling Capacity: 240,000 BTU/h

RCD Air Cooled Condensing Unit (50/60 Hz)

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

Product Data PH3Z 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS ( )

Concealed Ducted Split Series R22

SUBMITTAL DATA SHEET FEATURES. SPLIT-SYSTEM EVAPORATOR BLOWERS 7.5, 10, 15, 20 & 25 TONS MODELS: J07 thru 25NC, 2-PIPE J10 thru 20ND, 4-PIPE

Multi-Path RTU-TYPE 9 (RTU-1) CES-MPU-025-RE-VAV9

Si Series Model CE Residential Geothermal Heat Pump

DESCRIPTION FEATURES

ROOF TOP PACKAGE UNITS

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS

Product Data FF1E LEGACY LINE FAN COIL SIZES 018 THRU 037 FEATURES

VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT

R-22, 13 SEER 60 Hertz

TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz

6-1/3 and 7-1/2 Ton Split System Air Conditioner (3 Phase) 75 to 89 MBtuh R -22 Refrigerant. Nominal Capacity BTUH

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES

PACKAGE AIR CONDITIONERS

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES

CDI series. Engineering Submittal Sheet. Model SM Residential Geothermal Heat Pump. Standard Features. Overview and Certifications

Product Data. S Two-stage scroll compressor S Variable speed ECM blower motor Control

R6GP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Gas/Electric Units, with R-410A WARRANTY

GP4SN Series TECHNICAL SPECIFICATIONS. Single Packaged Electric Cooling Units. P4SN 10.3 EER Commercial System 7½ and 10 Ton Units

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

Tons BTU/h S.E.E.R* E.E.R** HSPF

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 24,000 BTUH. Rev. 1.3

GQ6SD Series. Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

ACPSE-P Series 50Hz 410A. Rooftop Units Cooling Capacity : 26 to 1388 MBH (8 to 407 kw) Heating Capacity : 28 to 1298 MBH (8 to 380 kw)

AIR-COOLED CONDENSING UNITS

S6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12.

FCVC Series VERTICAL FAN COILS

WE MAKE INDOOR AIR BETTER

N4A6. Product Specifications

A Division of Nailor International Inc. ECONOMY AIR HANDLERS

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]

Q6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

CH5000 Heat Recovery Ventilator

Product Catalog. NQ Series. Portable and Remote Air-Cooled Condenser Chillers 4 to 43 Tons

SUNLINE 2000 SINGLE PACKAGE GAS / ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS DESCRIPTION FEATURES

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

WCA4**4. Product Specifications

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS

SUNLINE 2000 (WORLD 50 HZ)

PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

GPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary

CDI series. Engineering Submittal Sheet. Model SM Residential Geothermal Heat Pump. Standard Features. Overview and Certifications

PHR5. Product Specifications

AIR-COOLED CONDENSING UNITS

HORIZONTAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT

DCH Commercial Contents Standard Features Cabinet Features

CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) 1800Aǂ 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

Product Catalog TSE Series Scroll Central Chillers

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil

McQuay Rooftop Water Source Heat Pumps Catalog 1106

CHP

High Profile Evaporator

HCH6. Product Specifications

RBV Sales Guide FAN COIL UNITS FLOOR-MOUNTED, VERTICAL

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS

Transcription:

Series Dedicated Outside Air Systems (DOAS) Engineering Guide Effective September 2017 Vertical and Horizontal Water-Cooled and Air-Cooled

Contents Product Features...3 Options...4 Air-Cooled Indoor Ducted Condenser Section...4 Air-Cooled Outdoor Propeller Fan Condenser...4 Physical Data - Section...5 7 Physical Data...8 Air-Cooled Indoor Ducted Condenser...8 Physical Data...9 Air-Cooled Outdoor Propeller Fan Condenser...9 Water-Cooled Performance Data (a) (b) (c)...10 11 Standard Scroll Compressor...10 Air-Cooled Performance Data (a) (b)...12 Indoor Ducted Condenser Standard Scroll Compressor(s)...12 Outdoor Propeller Fan Condenser Standard Scroll Compressor(s)...12 Air-Cooled Performance Data (a) (b)...13 Indoor Ducted Condenser Optional Digital Scroll Compressor(s)...13 Air-Cooled Performance Data (a) (b)...14 Outdoor Propeller Fan Condenser Optional Digital Scroll Compressor(s)...14 Blower Performance Data (a) (b) (c) (d)...15 OmegaAir - Horizontal / Vertical...15 Blower Performance Data (a) (b) (c) (d)...16 Indoor Ducted Condenser...16 Hot Water Coil Performance (a) (b)...17 Steam Coil Performance...17 Electrical Data...18 Cooling Only:...18 Cooling with Electric Heat:...18 Electrical Data...19 20 Scroll Compressor RLA:...20 Evaporator Motor FLA:...20 Outdoor Propeller Fan Condenser Motor FLA:...20 Digital Scroll Compressor RLA:...20 Indoor Ducted Condenser Motor FLA:...20 Electrical Heat Data...21 Electrical Data - Section (a) (b)...22 24 Electrical Data - Air-Cooled Cond. Section (a) (b) (c)..25 26 Electrical Data - Air-Cooled Outdoor Propeller Fan Condenser...27 Water-Cooled Piping Arrangements...28 Dimensions - Vertical...29 Dimensions - Horizontal...30 31 Indoor Ducted Condenser Dimensions...32 Indoor Ducted Condenser Sections...33 Optional Air Paths...33 Outdoor Propeller Fan Condenser...34 Service Clearances - Plan View...35 Miscellaneous Application Data...35 OmegaAir Section...36 Basic Model Designation...36 Air-Cooled Indoor Ducted Condenser...37 Basic Model Designation...37 Air-Cooled Outdoor Propeller Fan Condenser...38 Basic Model Designation...38 Subject to change without notice. 2

Product Features The OmegaAir System of 100% outside air units are available as water-cooled packaged units or air-cooled matched with a remote air-cooled condenser section. Systems are designed for indoor application in Vertical or Horizontal configuration. Vertical or Horizontal, Water-Cooled Packaged Unit Vertical or Horizontal, Air-Cooled with Remote Air-Cooled Condenser Section 1 15 Nominal Tons 150 to 3000 CFM R-410a Refrigerant Functionally run tested at the factory Vertical Cabinet galvanized metal with powder coated finish Horizontal Cabinet galvanized metal 3 Cabinet Sizes Insulation 2 Thermal / Acoustic Fiberglass (R-8) Fits through 32 doorway Vertical Choice of Discharge Air Path: Top or Straightthrough Horizontal Choice of Discharge Air Path: Front, Top or Bottom Aluminum Fin / Copper Tube Evaporator Coil Dual-circuited coil utilizing interlaced evaporator coil circuitry for excellent part load performance (4 to 15 Ton models) Reciprocating Compressor (1-Ton) Heavy Duty Scroll Compressors (2-Ton and larger) Co-Axial Water-Cooled Condenser w/ 2-Way, 150 psig Water Regulating Valve(s) OA3 Microprocessor Controller w/ Wall Mounted Display and 100 of Cable (Includes Outdoor Air Temp / Humid Sensor, Supply Air Temp Sensor and Space Temp / Humid Sensor) Remote On/Off Terminal Block Fire / Smoke Detector Terminal Blocks (devices optional) Front Access to All Components in Vertical configuration Compressor and all electrical components are located out of the air stream in a separate compartment for access to these components while the unit is operating Fast, Easy Connections for High/Low Voltage, water and condensate removal connections High and Low Pressure Switches Air Flow Proving Switch Single-point power supply Modulating Hot Gas Reheat Split Systems include Resealable (with or without electric heat) Fittings Aluminum Fin / Copper Tube Hot Gas Reheat Coil positioned horizontally (perpendicular to the evaporator coil) in Vertical configuration Belt-Drive Blowers with Adjustable Pulleys for ease of Field Adjustment to obtain air balance Sealed / Permanently lubricated motor bearings IAQ Sloped Stainless Steel Drain Pan Internally Mounted Condensate Trap in Vertical configuration MOP Type Thermal Expansion Valves Filter Driers High and Low Side Schrader Refrigerant Access Fittings Hot Gas Bypass on each circuit 2 Return Air Filter Frame 2, MERV 8 Pleated Throwaway Filters Subject to change without notice. 3

Options Digital Scroll Compressor(s) Hot Water & Steam Coils Electric Heat w/single Point Power Motor Upgrades for High Static Applications Water Regulating Valves available for 350 psig and/or 3-way applications (shipped loose, field installed) Electronic Head Pressure Control Valves (shipped loose, field installed) Elastomeric Foam Insulation (evaporator section only) Double Wall Construction Protective Coil Coating 4 Filter Frames MERV 11 and 13 Filters Condensate Pump (External), 115v required Non-Fused Disconnect Unit Mounted Display & Keypad BMS Serial Communication Board - BACnet (MS/TP or Ethernet), ModBus, LonWorks Firestat Smoke Detector Dry Contacts / Terminal Blocks»» Remote Alarm Output»» Outdoor Air Damper Open/Close»» Outdoor Air Damper End Switch Drain Pan Overflow Switch Phase Relay for indication of Phase Reversal or Loss of Phase (3-phase units only) Freezestat Dirty Filter Switch Hot Water Coil Valves Water Entrance on Left (Vertical Configuration) Air-Cooled Indoor Ducted Condenser Section Upgraded Motor Pillow Block Bearings Coated Drain Pan Protective Coil Coating Painted Cabinet Outdoor Modification Kit Acoustic Foam Insulation Double Wall, Construction Condenser Filter Rack w/ 2, Merv 8 Pleated Throwaway Filters Sheet Metal/Cabinet Changes Non-Fused Disconnect Refrigerant Interconnect Kits Air-Cooled Outdoor Propeller Fan Condenser Multi-Contactor with Fan Cycling Package (low ambient down to 40 F) Flooded Condenser Package (low ambient down to 20 F) Multi-Contactor with Vari-Speed (low ambient down to 20 F) Refrigerant Interconnect Kits Subject to change without notice. 4

Physical Data - Section Tons 1 1-1/2 2 2-1/2 3 Evaporator Supply Air (a) CFM Range 134-266 167-333 237-472 284-566 334-666 Evaporator Blower Evaporator Motors (b) Evaporator Coil Filter Compressor Water Regulating Valve (d) Water-Cooled Condenser (e) Weight (Net Operating) (f) Available Voltages Size 7 X 5 7 X 7 Qty. 1 Std. HP @ 0.25 ESP 1/4 Opt. HP @ 1.0 ESP N/A 1/4 (c) N/A 1/2 Rows 6 Face Area (Ft. 2 ) 0.67 0.83 1.18 1.42 1.67 FPI 10 Type Pleated Throwaway Qty 1 Size (in.) Vertical 12 x 24 x 2, Horizontal 18 x 24 x 2 Efficiency MERV 8 Type Recip. Scroll Qty 1 Size (in.) 3/8 1/2 3/4 Qty 1 GPM 3 4.5 6 7.5 9 Press. Drop (Ft. H2O) 5.7 6.3 13.3 10.6 8.9 Air-Cooled Vert. 507 510 517 539 552 Water-Cooled Vert. 517 524 534 562 575 Air-Cooled Horiz. 422 425 433 455 467 Water-Cooled Horiz. 432 438 448 476 490 208/230-1-60 208/230-3-60 460-3-60 (a) Air flow performance may require other than standard drive components. (b) Motor Size based on 200 CFM/ton with no options. Run selection on UCA Select to verify proper motor size based on actual unit configuration. (c) Drive set upgrade only. (d) Standard water regulating valve is 2-way, 150 psig. Optional valve configurations available in 3-way and 350 psig. Optional valves ship loose for field installation. (e) Pressure Drop is for co-axial condenser only and does not include water regulating valve(s). (f) Net operating weight is for basic unit only. Options will add weight. Subject to change without notice. 5

Physical Data - Section Tons 4 5 6 7 8 Evaporator Supply Air (a) CFM Range 445 888 567 1133 667-1333 756-1511 977-1952 Evaporator Blower Evaporator Motors (b) Evaporator Coil Filter Compressor Water Regulating Valve (d) Water-Cooled Condenser (e) Weight (Net Operating) (f) Available Voltages Size 10 X 8 Qty 1 Std. HP @ 0.25 ESP 1/4 1/3 1/2 3/4 (H), 1/2 (V) Opt. HP @ 1.0 ESP 1/2 3/4 1 Rows 6 Face Area 2.22 2.83 3.33 3.78 4.88 FPI 10 Type Pleated Throwaway Qty 2 Size (in.) Vertical 20 x 25 x 2, Horizontal 20 x 24 x 2 Efficiency MERV 8 Type Qty Scroll 2 (g) Size (in.) 1/2 3/4 Qty 2 GPM 12 15 18 21 24 Press. Drop (Ft. H2O) 13.1 10.3 8.7 13.6 12.6 Air-Cooled Vert. 728 769 777 812 851 Water-Cooled Vert. 767 814 828 875 914 Air-Cooled Horiz. 643 669 692 731 766 Water-Cooled Horiz. 692 737 745 782 821 208/230-1-60 N/A N/A N/A 208/230-3-60 460-3-60 (a) Air flow performance may require other than standard drive components (b) Motor Size based on 200 CFM/ton with no options. Run selection on UCA Select to verify proper motor size based on actual unit configuration. (c) Drive set upgrade only. (d) Standard water regulating valve is 2-way, 150 psig. Optional valve configurations available in 3-way and 350 psig. Optional valves ship loose for field installation. (e) Pressure Drop is for co-axial condenser only and does not include water regulating valve(s). (f) Net operating weight is for basic unit only. Options will add weight. (g) 4 and 5 Ton units with optional digital scroll compressors are available as single circuit only. Subject to change without notice. 6

Physical Data - Section Tons 9 10 11 12 13.5 15 Evaporator Supply Air (a) CFM Range 1039-2077 1134-2266 1334-2666 1334-2666 1467-2933 1800-3600 Evaporator Blower Evaporator Motors (b) Evaporator Coil Filter Compressor Water Regulating Valve (d) Water-Cooled Condenser (e) Weight (Net Operating) (f) Available Voltages Size 12 X 9 Qty 1 Std. HP @ 0.25 ESP 1/2 3/4 1 1-1/2 Opt. HP @ 1.0 ESP 3/4 1 1-1/2 2 Rows 6 Face Area 5.19 5.67 6.67 6.67 7.33 9.0 FPI 10 Type Pleated Throwaway Qty 3 Size (in.) Vertical 20 x 25 x 2, Horizontal 20 x 25 x 2 Efficiency MERV 8 Type Qty 2 Scroll Size (in.) 1 1-1/4 Qty 2 GPM 27 30 33 36 40 45 Press. Drop (Ft. H2O) 7.7 9.6 13.0 14.9 14.8 17.8 Air-Cooled Vert. 1062 1104 1116 1126 1157 1256 Water-Cooled Vert. 1137 1179 1208 1218 1273 1372 Air-Cooled Horiz. 877 917 929 941 974 1080 Water-Cooled Horiz. 960 1002 1020 1035 1086 1186 208/230-1-60 N/A N/A N/A N/A N/A N/A 208/230-3-60 460-3-60 (a) Air flow performance may require other than standard drive components. (b) Motor Size based on 200 CFM/ton with no options. Run selection on UCA Select to verify proper motor size based on actual unit configuration. (c) Drive set upgrade only. (d) Standard water regulating valve is 2-way, 150 psig. Optional valve configurations available in 3-way and 350 psig. Optional valves ship loose for field installation. (e) Pressure Drop is for co-axial condenser only and does not include water regulating valve(s) (f) Net operating weight is for basic unit only. Options will add weight. Subject to change without notice. 7

Physical Data Air-Cooled Indoor Ducted Condenser Condenser Air Condenser Blower Condenser Motors (b) Condenser Coil Weight (Net Operating) (d) Available Voltages Condenser Model BCSP12 BCSP18 BC2 BC3 BC4G*AS BC5G*AS OmegaAir Tons 1 1-1/2 2 2-1/2, 3 4 (a) 5 (a) CFM 700 850 1600 2000 2500 3300 Std. ESP 0.25 Max. ESP 2.0 1.7 2.0 1.9 Size 7 x 7 12 x 9 Qty 1 Std. HP @ 0.25 ESP 1/2 3/4 1 1-1/2 2 Opt. HP @ 1.5 ESP 3/4 3/4 1 1-1/2 2 3 Rows 3 4 Face Area 2.6 4.4 FPI 14 12 Air-Cooled 275 285 365 385 550 595 208/230-1-60 N/A 208/230-3-60 N/A 460-3-60 N/A Condenser Air Condenser Blower Condenser Motors (b) Condenser Coil Weight (Net Operating) (d) Available Voltages Condenser Model BC4G*A BC5G*A BC6 BC8 BC10 BC12 BC15 OmegaAir Tons 4 (dual) 5 (dual) 6 7, 8 9, 10 11, 12 13.5, 15 CFM 2500 3300 3800 4250 6000 6000 7500 Std. ESP 0.25 Max. ESP 2.0 1.9 0.6 Size 15 x 9 15 x 15 Qty 1 Std. HP @ 0.25 ESP 1-1/2 2 3 7-1/2 10 Opt. HP @ 1.5 ESP 2 3 5 (c) N/A Rows 6 8 Face Area 6.4 7.3 FPI 12 Air-Cooled 590 650 665 750 795 820 1005 208/230-1-60 N/A N/A N/A N/A N/A 208/230-3-60 460-3-60 (a) Single circuit condenser is only matched with a single circuit 4 or 5 ton OmegaAir unit with the optional digital scroll compressor. (b) Motor Size based on standard CFM/ton with no options. Run selection on UCA Select to verify proper motor size based on actual unit configuration. (c) Drive set upgrade only. (d) Net operating weight is for basic unit only. Options will add weight. Subject to change without notice. 8

Physical Data Air-Cooled Outdoor Propeller Fan Condenser Propeller Fan Condenser Coil Weight (Net Operating) (b) Available Voltages Condenser Model PBC2 PBC3 PBC4 PBC5 PBC7 (a) PBC10 (a) OmegaAir Tons 1 1-1/2 2 2-1/2, 3 4 5, 6 QTY. 1 1 2 Motor HP 1/3 1/2 each Diameter (in.) 20 24 Rows 1 2 2 3 3 2 Face Area 6.3 11.1 22.2 FPI 8 12 8 Air-Cooled 115 125 135 225 270 400 208/230-1-60 (c) 208/230-3-60 N/A 460-3-60 N/A Propeller Fan Condenser Coil Weight (Net Operating) (b) Available Voltages Condenser Model PBC15 PBC18 PBC21 PBC23 PBC28 PBC31 OmegaAir Tons 7, 8 9 10, 11 12 13.5 15 QTY. 2 3 4 Motor HP 1/2 each Diameter (in.) 24 Rows 3 2 3 Face Area 22.2 33.3 44.4 FPI 10 9 8 10 8 10 Air-Cooled 475 580 650 710 850 935 208/230-1-60 N/A N/A N/A N/A N/A N/A 208/230-3-60 460-3-60 (a) Single and Dual circuits available. (b) Net operating weight is for basic unit only. Options will add weight. (c) Single phase is available only on the 5 Ton OmegaAir unit. Subject to change without notice. 9

Water-Cooled Performance Data (a) (b) (c) Standard Scroll Compressor Tons CFM 1 220 Entering Air Temp. ( F) Cooling (Btuh) Leaving Air Temp. ( F) DB WB Total Sensible DB WB GPM Leaving Water Temp. ( F) 17,545 9,700 55.7 55.6 3 98.4 1-1/2 333 23,360 13,300 59.6 59.1 4.5 97.4 2 350 28,780 15,730 54.6 54.6 6 96.7 2-1/2 450 36,360 19,790 55.3 55.3 7.5 96.5 3 510 41,980 22,840 54.8 54.8 9 95.9 4 710 57,971 31,510 55.1 55.1 12 95.9 5 900 72,530 39,561 55.3 55.3 15 96.6 6 1000 82,660 44,940 54.5 54.5 18 96.4 95 78 7 1250 99,390 54,480 55.8 55.7 21 96.0 8 1450 119,420 64,820 54.7 54.6 24 96.8 9 1550 126,820 69,190 54.8 54.8 27 96.7 10 1750 143,220 78,140 54.9 54.9 30 96.7 11 2000 160,350 87,780 55.5 55.5 33 96.5 12 2100 168,840 92,550 55.4 55.4 36 96.1 13.5 2400 191,280 105,010 55.8 55.7 40 96.2 15 2500 231,760 116,540 54.9 54.9 45 95.9 (a) Capacities are gross values, not adjusted for motor heat (b) Some refrigerant circuit components may impact unit capacities (c) Entering Water Temperature 85 F Subject to change without notice. 10

Water-Cooled Performance Data (a) (b) (c) Digital Scroll Compressor Tons 3 4 5 6 7 8 9 10 11 12 13.5 15 CFM 490 Entering Air Temp. ( F) Cooling (Btuh) Leaving Air Temp. ( F) DB WB Total Sensible DB WB GPM Leaving Water Temp. ( F) 78 40,430 21,980 54.6 54.6 9 95.6 440 80 40,300 19,650 54.8 54.8 9 95.6 620 78 50,560 27,600 54.9 54.9 12 94.9 550 80 50,130 24,520 54.8 54.8 12 94.9 850 78 69,490 37,870 54.8 54.8 15 95.9 760 80 69,160 33,830 54.9 54.9 15 95.9 980 78 80,230 43,800 54.8 54.8 18 96.2 870 80 79,690 38,920 54.7 54.7 18 96.2 1200 78 98,110 53,480 54.9 54.9 21 95.9 1070 80 97,550 47,650 54.9 54.9 21 95.9 1475 78 120,840 65,790 54.9 54.9 24 97.0 1310 80 119,950 58,510 54.8 54.8 24 97.0 95 1550 78 126,650 69,090 54.8 54.8 27 96.6 1380 80 125,910 61,570 54.8 54.8 27 96.6 1750 78 143,880 78,210 54.8 54.8 30 96.9 1560 80 143,090 69,810 54.8 54.8 30 96.8 1940 78 158,650 86,530 54.9 54.9 33 96.5 1710 80 157,320 76,800 54.7 54.7 33 96.4 2050 78 167,590 91,490 54.9 54.9 36 96.0 1810 80 166,100 81,340 54.9 54.8 36 95.8 2300 78 189,050 102,960 54.9 54.9 40.5 96.1 2040 80 187,690 91,800 54.9 54.8 40.5 96.1 2570 78 211,860 115,240 54.8 54.8 45 95.8 2290 80 210,760 102,990 54.9 54.9 45 95.7 (a) Capacities are gross values, not adjusted for motor heat (b) Some refrigerant circuit components may impact unit capacities (c) Entering Water Temperature 85 F Subject to change without notice. 11

Indoor Ducted Condenser Standard Scroll Compressor(s) OmegaAir Tons Condenser Model OmegaAir CFM Entering Air Temp. ( F) Cooling (Buth) Leaving Air Temp. ( F) DB WB Total Sensible DB WB 1 BCSP12G*ASTA 200 14,800 8,450 57.9 57.7 1-1/2 BCSP18G*ASTA 300 20,010 11,539 60.7 60.4 2 BC2G*ASTA 325 25,060 13,980 56.8 56.8 2-1/2 BC3G*ASTA 400 31,200 17,330 56.5 56.5 3 BC3G*ASTA 450 35,380 19,440 56.5 56.5 4 BC4G*ATA 640 50,560 27,980 56.1 56.1 5 BC5G*ATA 840 64,990 36,020 56.5 56.5 6 BC6G*ATA 950 75,000 41,230 56.1 56.1 95 78 7 BC8G*ATA 1125 85,860 47,740 57.0 57.0 8 BC8G*ATA 1300 101,590 55,970 56.3 56.3 9 BC10G*ATA 1450 114,680 63,090 55.9 55.9 10 BC10G*ATA 1650 127,870 70,910 56.4 56.4 11 BC12G*ATA 1750 137,480 75,880 56.1 56.1 12 BC12G*ATA 1900 144,850 80,670 56.9 56.9 13.5 BC15G*ATA 2250 166,670 93,380 57.7 57.7 15 BC15G*ATA 2300 181,310 99,940 56.0 56.0 Outdoor Propeller Fan Condenser Standard Scroll Compressor(s) OmegaAir Tons Condenser Model Air-Cooled Performance Data (a) (b) (c) OmegaAir CFM Entering Air Temp. ( F) Cooling (Buth) Leaving Air Temp. ( F) DB WB Total Sensible DB WB 1 PBC2G*ASTA 200 15,380 8,700 56.8 56.6 1-1/2 PBC3G*ASTA 330 21,700 12,660 60.8 60.3 2 PBC4G*ASTA 340 26,710 14,850 56.2 56.2 2-1/2 PBC5G*ASTA 440 34,050 18,890 56.5 56.5 3 PBC5G*ASTA 490 38,660 21,370 55.9 55.9 4 PBC7G*ATA 660 52,110 28,920 56.2 56.2 5 PBC10G*ATA 890 68,130 37,910 56.8 56.8 6 PBC10G*ATA 990 77,360 42,960 56.2 56.2 95 78 7 PBC15G*ATA 1230 92,060 51,550 57.4 57.4 8 PBC15G*ATA 1400 110,040 60,780 56.1 56.1 9 PBC18G*ATA 1500 115,880 64,270 56.6 56.6 10 PBC21G*ATA 1750 134,430 74,520 56.7 56.7 11 PBC21G*ATA 1900 145,750 80,870 56.8 56.8 12 PBC23G*ATA 2010 153,800 85,620 56.8 56.8 13.5 PBC28G*ATA 2370 176,620 98,460 57.7 57.6 15 PBC31G*ATA 2450 195,000 107,250 55.7 55.7 (a) Capacities are gross values, not adjusted for motor heat. (b) Some refrigerant circuit components may impact on unit capacities. (c) Ambient Air Temperature 95 F Subject to change without notice. 12

Air-Cooled Performance Data (a) (b) Indoor Ducted Condenser Optional Digital Scroll Compressor(s) OmegaAir Tons Condenser Model 3 BC3G*ASTA 4 BC4G*ASTA 5 BC5G*ASTA 6 BC6G*ATA 7 BC8G*ATA 8 BC8G*ATA 9 BC10G*ATA 10 BC10G*ATA 11 BC12G*ATA 12 BC12G*ATA 13.5 BC15G*ATA 15 BC15G*ATA Entering Air Temp. ( F) Leaving Air Temp. ( F) CFM Cooling (Buth) DB WB Total Sensible DB WB 400 78 33,160 18,050 54.7 54.6 350 80 32,730 15,910 54.4 54.2 530 78 43,510 23,830 54.8 54.8 470 80 43,030 21,130 54.8 54.8 710 78 57,880 31,660 54.9 54.9 630 80 57,390 28,330 54.9 54.9 860 78 70,880 38,680 54.8 54.8 760 80 70,190 34710 54.7 54.7 1000 78 82,890 45,220 54.6 54.6 900 80 82,320 40,230 54.7 54.7 1200 78 99,450 54,090 54.7 54.6 1070 80 98,710 48,130 54.7 54.6 95 1380 78 112,840 61,640 54.9 54.9 1220 80 111,780 54,690 54.8 54.8 1550 78 126,190 69,080 54.9 54.9 1370 80 125,130 61,220 54.8 54.8 1650 78 135,040 73,620 54.8 54.8 1470 80 134.070 65,580 54.9 54.9 1730 78 140,870 77,040 54.9 54.9 1530 80 139,620 68,650 54.8 54.8 1960 78 159,880 87,480 54.9 54.9 1740 80 158,920 77,850 54.9 54.9 2180 78 177,280 96,820 54.9 54.9 1930 80 176,190 86,180 54.9 54.9 (a) Capacities are gross values, not adjusted for motor heat. (b) Some refrigerant circuit components may impact on unit capacities. (c) Ambient Air Temperature 95 F Subject to change without notice. 13

Air-Cooled Performance Data (a) (b) (c) Outdoor Propeller Fan Condenser Optional Digital Scroll Compressor(s) OmegaAir Tons Condenser Model 3 PBC5G*ASTA 4 PBC7G*ASTA 5 PBC10G*ASTA 6 PBC10G*ATA 7 PBC15G*ATA 8 PBC15G*ATA 9 PBC18G*ATA 10 PBC21G*ATA 11 PBC21G*ATA 12 PBC23G*ATA 13.5 PBC28G*ATA 15 PBC31G*ATA CFM 450 Entering Air Temp. ( F) Cooling (Buth) Leaving Air Temp. ( F) DB WB Total Sensible DB WB 78 36,760 20,130 54.9 54.9 400 80 36,510 17,860 54.9 54.9 550 78 45,090 24,630 54.8 54.8 490 80 44,710 21,860 54.9 54.9 780 78 63,550 34,690 54.9 54.9 690 80 62,980 30,770 54.8 54.8 900 78 73,470 40,320 54.9 54.9 800 80 72,980 35,770 55.0 55.0 1090 78 88,930 48,730 54.9 54.9 960 80 88,180 43,050 54.7 54.7 1330 78 108,760 59,480 54.9 54.9 1170 80 107,620 52,580 54.7 54.7 95 1380 78 112,860 61,590 55.0 55.0 1220 80 111,840 54,600 54.9 54.9 1610 78 131,940 71,970 54.8 54.8 1430 80 131,030 63,970 54.8 54.8 1730 78 141,870 77,410 54.8 54.8 1540 80 140,930 68,900 54.9 54.9 1830 78 149,600 81,840 54.9 54.9 1630 80 148,810 72,910 54.9 54.9 2070 78 169,070 92,450 54.9 54.9 1830 80 167,950 82,170 54.8 54.8 2340 78 191,150 104,230 54.9 54.9 2070 80 189,730 92,580 54.9 54.9 (a) Capacities are gross values, not adjusted for motor heat. (b) Some refrigerant circuit components may impact on unit capacities. (c) Ambient Air Temperature 95 F. Subject to change without notice. 14

Blower Performance Data (a) OmegaAir - Horizontal / Vertical External Static Pressure (ESP) Tons CFM 0.25 0.50 0.75 1.00 1.25 1.5 1.75 2.0 HP 1 200 1/4 1/4 - - - - - - - - - - - - - - - - - - 1-1/2 300 1/4 1/4 1/4 1/4 1/4 1/4 1/4 - - - 2 400 1/4 1/4 1/4 1/4 1/4 1/4 1/3 1/3 2-1/2 500 1/4 1/4 1/3 - - - - - - - - - - - - - - - 3 600 1/4 1/4 1/3 1/2 - - - - - - - - - - - - 4 800 1/4 1/4 1/3 1/2 1/2 1/2 3/4 3/4 5 1000 1/4 1/3 1/2 1/2 3/4 3/4 3/4 3/4 6 1200 1/3 1/2 1/2 3/4 3/4 3/4 1 1 7 1400 1/2 1/2 3/4 3/4 1 1 1 1-1/2 8 1600 1/2 3/4 3/4 1 1 1-1/2 1-1/2 1-1/2 9 1800 1/2 3/4 3/4 3/4 1 1 1-1/2 1-1/2 10 2000 3/4 3/4 3/4 1 1 1-1/2 1-1/2 1-1/2 11 2200 3/4 3/4 1 1 1-1/2 1-1/2 1-1/2 1-1/2 12 2400 3/4 1 1-1/2 1-1/2 1-1/2 1-1/2 2 2 13.5 2700 1 1-1/2 1-1/2 1-1/2 2 2 2 3 15 3000 1-1/2 1-1/2 1-1/2 2 2 2 3 3 (a) Blower performance of basic unit with 2, MERV 8 pleated filter and wet coil 95 / 78. Run selection on UCA Select to verify proper motor size based on actual unit configuration. Subject to change without notice. 15

Blower Performance Data (a) Indoor Ducted Condenser External Static Pressure (ESP) Tons CFM 0.25 0.50 0.75 1.00 1.25 1.5 1.75 2.0 HP BCSP12 700 1/2 1/2 1/2 1/2 1/2 3/4 3/4 3/4 BCSP18 850 1/2 1/2 1/2 1/2 3/4 3/4 1 1 BC2 1600 3/4 3/4 3/4 3/4 3/4 1 1 1 BC3 2000 1 1 1 1 1 1.5 1.5 1.5 BC4G*A (dual) 2500 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 2 2 2 BC5G*A (dual) 3300 2 2 2 2 3 3 3 3 BC6 3800 3 3 3 3 3 5 5 5 BC8 4250 3 3 5 5 5 5 5 5 BC10 6000 7-1/2 7-1/2 7-1/2 7-1/2 7-1/2 7-1/2 7-1/2 n/a BC12 6000 7-1/2 7-1/2 7-1/2 7-1/2 7-1/2 7-1/2 7-1/2 n/a BC15 7500 10 10 n/a n/a n/a n/a n/a n/a BC4G*AS 2500 1-1/2 1-1/2 1-1/2 1-1/2 2 2 2 2 BC5G*AS 3300 2 2 3 3 3 3 3 - - - (a) Blower performance of basic unit. Run selection on UCA Select to verify proper motor size based on actual unit configuration. Subject to change without notice. 16

Hot Water Coil Performance (a) (b) Contact the factory for hot water coil performance that will be specific for your application. Please provide: Entering water temperature Desired / Approximate leaving water temperature (typically a 20 difference) Entering air temperature Fluid type Indicate if Optional Hot Water Valve is to be factory supplied. Valves are spring return, On / Off operation only. Steam Coil Performance Contact the factory for steam coil performance that will be specific for your application. Steam coils are suitable for 10 psi or less steam pressure. Steam valves and components are by others, field installed. Subject to change without notice. 17

Electrical Data The following sections provide the formulas and the data to calculate the Minimum Circuit Ampacity (MCA) and the Maximum Overcurrent Protection (MOP) for a variety of unit configurations. The formulas refer to the largest motor amps. Typically this is the compressor (RLA) but it can also be one of the blower motors (FLA). Please note that the UCA Select software program is also available to calculate electrical data and provide unit submittals, drawing reports and pricing information. Cooling Only: NOTE: Largest motor amps may not always be the compressor. MCA = (1.25 x largest motor amps) + the sum of the remaining motor amps MOP = (2.25 x largest motor amps) + the sum of the remaining motor amps Note: Round calculated MOP value down to the nearest 5 amp increment. Packaged OmegaAir Unit - Water-Cooled (can be single or dual compressor) EXAMPLE 1: EXAMPLE 2: 2 Ton Water-cooled, 208/230-3-60 6 Ton Water-cooled, 460-3-60 Single Compressor RLA = 8.3 Dual Compressors RLA = 6.0 each Evap Blwr. Motor (1/4 HP) FLA = 1.3 Evap Blwr. Motor (3/4 HP) FLA = 1.5 MCA = (1.25 x 8.3) + 1.3 = 11.7 MCA = (1.25 x 6.0) + 6.0 + 1.5 = 15.0 MOP = (2.25 x 8.3) + 1.3 = 19.98 calculated MOP = (2.25 x 6.0) + 6.0 + 1.3 = 20.8 calculated MOP = 15 (rounded down to nearest 5) MOP = 20 (rounded down to nearest 5) Split-system OmegaAir, matched w/ Indoor Ducted Air-Cooled Condenser (can be single or dual compressor) EXAMPLE 3: 8 Ton OmegaAir, 208/230-3-60 8 Ton Indoor Ducted Condenser, 208/230-3-60 Dual Compressors RLA = 16.0 each Cond Blwr. Motor (3 HP) FLA = 8.8 Evap Blwr. Motor (1 HP) FLA = 4.0 MCA = (1.25 x 16.0) + 16.0 + 4.0 = 40.0 MCA = (1.25 x 8.8) = 11.0 MOP = (2.25 x 16.0) + 16.0 + 4.0 = 56.0 calculated MOP = (2.25 x 8.8) = 19.8 calculated MOP = 55 (rounded down to nearest 5) MOP = 15 (rounded down to nearest 5) Cooling with Electric Heat: On equipment with multiple modes of operation (i.e. cooling and heating), each mode must be evaluated and whichever load condition provides the highest value shall be used. NOTE: Largest motor amps may not always be the compressor. Use the larger of the following: MCAclg = (1.25 x largest motor amps) + the sum of the remaining motor amps MCAhtg = 1.25 x (heater amps + evap motor FLA) MOPclg = (2.25 x largest motor amps) + the sum of the remaining motor amps MOPhtg = (2.25 x evap motor FLA) + heater amps Note: Round calculated MOP value down to the nearest 5 amp increment. MOP must be greater than MCA. If the rounded MOP is less than the MCA, then the MOP is equal to the MCA value rounded UP to the next 5 amp increment. Subject to change without notice. 18

Electrical Data Packaged OmegaAir - Water-Cooled w/ Electric Heat (can be single or dual compressor) EXAMPLE 4: 2 Ton Water-cooled, 208/230-3-60 Single Compressor RLA = 8.3 Evap Blwr. Motor (1/4 HP) FLA = 1.3 5 kw Electric Heat (heat only) = 13.1 amps MCAclg = (1.25 x 8.3) + 1.3 = 11.7 MCAhtg = 1.25 x (13.1 x 1.3) = 18.0 MCA = 18.0 MOPclg = (2.25 x 8.3) + 1.3 = 19.98 calculated, 15 (rounded down to nearest 5) MOPhtg = (2.25 x 1.3) + 13.1 = 16.0 calculated, 15 (rounded down to nearest 5) MOP = 20 Note: MOP must be greater than MCA. The cooling and heating rounded MOP s are less than the MCA. MOP is then determined by rounding up the MCA to nearest 5 amp increment above the MCA. Split-system OmegaAir w/ Electric Heat, matched w/ Indoor Ducted Air-Cooled Condenser (can be single or dual compressor) EXAMPLE 5: 8 Ton OmegaAir, 208/230-3-60 8 Ton Indoor Ducted Condenser, 208/230-3-60 Dual Compressors RLA = 16.0 each Cond Blwr. Motor (3 HP) FLA = 8.8 Evap Blwr. Motor (1 HP) FLA = 4.0 MCA = (1.25 x 8.8) = 11.0 20 kw Electric Heat (heat only) = 52.5 amps MOP = (2.25 x 8.8) = 19.8 calculated MCAclg = (1.25 x 16.0) + 16.0 + 4.0 = 40.0 MOP = 15 (rounded down to nearest 5) MCAhtg = 1.25 x (4.0 + 52.5) = 70.6 MCA = 70.6 MOPclg = (2.25 x 16.0) + 16.0 + 4.0 = 56.0 calculated, 55 (rounded down to nearest 5) MOPhtg = (2.25 x 4.0) + 52.5 = 61.5 calculated, 60 (rounded down to nearest 5) MOP = 75 Note: MOP must be greater than MCA. The cooling and heating rounded MOP s are less than the MCA. MOP is then determined by rounding up the MCA to nearest 5 amp increment above the MCA. Subject to change without notice. 19

Electrical Data Scroll Compressor RLA: OmegaAir Tons Compressor (Qty) 208/230-1-60 208/230-3-60 460-3-60 1 1 (Recip) 5.9 n/a n/a 1-1/2 1 13.5 7.1 3.5 2 1 12.8 8.3 5.1 2-1/2 1 16.7 10.4 5.8 3 1 17.9 13.5 6.0 4 2 12.8 ea. 8.3 ea. 5.1 ea. 5 2 16.7 ea. 10.4 ea. 5.8 ea. 6 2 - - - 13.5 ea. 6.0 ea. 7 2 - - - 13.7 ea. 6.2 ea. 8 2 - - - 16.0 ea. 7.8 ea. 9 2 - - - 15.6 ea. 7.8 ea. 10 2 - - - 19.0 ea. 9.7 ea. 11 2 - - - 22.4 ea. 10.6 ea. 12 2 - - - 23.2 ea. 11.2 ea. 13.5 2 - - - 25.0 ea. 12.2 ea. 15 2 - - - 29.5 ea. 14.7 ea. Evaporator Motor FLA: HP 208/230-1-60 208/230-3-60 460-3-60 1/4 2.5 1.3 0.65 1/3 3.2 1.6 0.80 1/2 4.5 2.4 1.2 3/4 5.8 3.0 1.5 1 6.3 4.0 2.0 1-1/2 7.8 5.6 2.8 2 11.3 6.2 3.1 3 - - - 9.2 4.3 5 - - - 13.6 6.3 Digital Scroll Compressor RLA: OmegaAir Tons Compressor (Qty) 208/230-1-60 208/230-3-60 460-3-60 3 1 18.5 11.7 6.2 4 1 20.2 16.1 7.8 5 1 n/a 20.4 9.7 6 2 - - - 11.7 ea. 6.2 ea. 7 2 - - - 16.1 ea. 7.8 ea. 8 2 - - -. 17.9 ea. 7.8 ea. 9 2 - - - 16.9 ea. 8.1 ea. 10 2 - - -. 20.4 ea. 9.7 ea. 11 2 - - - n/a 9.5 ea. 12 2 - - - 23.2 ea. 11.2 ea. 13.5 2 - - - 24.0 ea. 12.6 ea. 15 2 - - - 27.6 ea. 12.8 ea. Indoor Ducted Condenser Motor FLA: HP 208/230-1-60 208/230-3-60 460-3-60 1/2 3.8 2.2 1.3 3/4 5.8 3.2 1.5 1 7.0 3.4 1.6 1-1/2 9.4 5.0 2.4 2 13.7 6.5 3.1 3 18.0 8.8 4.2 5 - - - 13.5 6.5 7.5 - - - 18.0 9.0 10 - - - 28.0 14.0 Outdoor Propeller Fan Condenser Motor FLA: HP Used In Models Fan Qty 208/230-1-60 208/230-3-60 460-3-60 1/3 PBC2 PBC5 1 1.9 2.8 1.0 1/2 PBC6 PBC7 1 3.6 2.8 1.2 1/2 PBC10 PBC15 2 3.6 ea. (a) 2.8 ea. 1.2 ea. 1/2 PBC18 PBC23 3 - - - 2.8 ea. 1.2 ea. 1/2 PBC28 PBC31 4 - - - 2.8 ea. 1.2 ea. (a) Single phase is only available on PBC10. Subject to change without notice. 20

Electrical Heat Data (a) (b) (c) (d) Nominal kw OmegaAir Tons Electric Heat Amps 208/230-1-60 208/230-3-60 460-3-60 2 1, 1.5, 2, 2.5 9.1 5.3 2.5 3 1, 1.5, 2, 2.5, 3, 4 13.6 7.9 3.8 5 1, 1.5, 2, 2.5, 3, 4, 5, 6, 7 22.7 13.1 6.3 6 1, 1.5, 2, 2.5, 3, 4, 5, 6, 7 27.3 15.8 7.5 7.5 1.5, 2, 2.5, 3, 4, 5, 6, 7, 8, 9, 10 34.1 19.7 9.4 10 2, 2.5, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13.5 45.5 26.2 12.6 12.5 2.5, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13.5, 15 - - - 32.8 15.7 15 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13.5, 15 - - - 39.4 18.8 20 4, 5, 6, 7, 8, 9, 10, 11, 12, 13.5, 15 - - - 52.5 25.1 25 5, 6, 7, 8, 9, 10, 11, 12, 13.5, 15 - - - 65.6 31.4 30 6, 7, 8, 9, 10, 11, 12, 13.5, 15 - - - 78.7 37.7 35 7, 8, 9, 10, 11, 12, 13.5, 15 - - - 91.9 43.9 40 8, 9, 10, 11, 12, 13.5, 15 - - - 105 50.2 45 8, 9, 10, 11, 12, 13.5, 15 - - - 118.1 56.5 50 9, 10, 11, 12, 13.5, 15 - - - 131.2 62.8 55 10, 11, 12, 13.5, 15 - - - 144.3 69 60 11, 12, 13.5, 15 - - - 157.5 75.3 65 13.5, 15 - - - 170.6 81.6 70 15 - - - 183.7 87.9 (a) Open Wire Electric Heaters come with SCR Controller, as standard. (b) Heaters are nominally rated (kw) at 220 or 460 volts. Amps listed at 220 or 460 volts. (c) All size heaters are installed in Extended Filter Box and available for Heat Only (not reheat). (d) Unit has single point power with electric heat. Subject to change without notice. 21

Electrical Data - Section (a) (b) Tons Model Voltage Compressor RLA Evaporator Motor Unit Electric Heat Unit w/ Electric Heat HP FLA MCA MOP KW Amps MCA MOP 1 OS* 1G1ASFTA 208/230-1-60 5.9 1/4 2.5 9.9 15 5 22.7 31.5 35 1-1/2 2 2-1/2 3 OS* 1.5G1ASFTA 208/230-1-60 13.5 1/4 2.5 19.4 30 7.5 34.1 45.8 50 OS* 1.5G3ASFTA 208/230-3-60 7.1 1/4 1.3 10.2 15 7.5 19.7 26.3 30 OS* 1.5G4ASFTA 460-3-60 3.5 1/4 0.65 5.0 10 7.5 9.4 12.6 15 OS* 2G1ASFTA 208/230-1-60 12.8 OS* 2G3ASFTA 208/230-3-60 8.3 OS* 2G4ASFTA 460-3-60 5.1 OS* 2.5G1ASFTA 208/230-1-60 16.7 OS* 2.5G3ASFTA 208/230-3-60 10.4 OS* 2.5G4ASFTA 460-3-60 5.8 OS* 3G1ASFTA 208/230-1-60 17.9 OS* 3G3ASFTA 208/230-3-60 13.5 OS* 3G4ASFTA 460-3-60 6.0 (a) Use Copper Conductors Only. (b) Values listed are typical and may vary dependent upon components utilized. * Either Water-Cooled (W) or Air-Cooled (A) Either Vertical (V) or Horizontal (H) 1/4 2.5 18.5 30 10 45.5 60.0 65 1/3 3.2 19.2 30 10 45.5 60.9 65 1/4 1.3 11.7 15 10 26.2 34.4 35 1/3 1.6 12.0 20 10 26.2 34.8 35 1/4 0.65 7.0 10 10 12.6 16.6 20 1/3 0.80 7.2 10 10 12.6 16.8 20 1/4 2.5 23.4 40 10 45.5 60.0 65 1/3 3.2 24.1 40 10 45.5 60.9 65 1/4 1.3 14.3 20 10 26.2 34.4 35 1/3 1.6 14.6 25 10 26.2 34.8 35 1/4 0.65 7.9 10 10 12.6 16.6 20 1/3 0.80 8.1 10 10 12.6 16.8 20 1/4 2.5 24.9 40 10 45.5 60.0 65 1/3 3.2 25.6 40 10 45.5 60.9 65 1/2 3.6 26.0 40 10 45.5 62.5 65 1/4 1.3 18.2 30 15 39.4 50.9 55 1/3 1.6 18.5 30 15 39.4 51.3 55 1/2 2.4 19.3 30 15 39.4 52.3 55 1/4 0.65 8.2 10 15 18.8 24.3 25 1/3 0.80 8.3 10 15 18.8 24.5 25 1/2 1.2 8.7 10 15 18.8 25.0 30 Subject to change without notice. 22

Electrical Data - Section (a) (b) Tons Models Voltage 4 5 6 7 8 Compressor RLA OS* 4G1AFTA 208/230-1-60 12.8 ea. OS* 4G3AFTA 208/230-3-60 8.3 ea. OS* 4G4AFTA 460-3-60 5.1 ea. OS* 5G1AFTA 208/230-1-60 16.7 ea. OS* 5G3AFTA 208/230-3-60 10.4 ea. OS* 5G4AFTA 460-3-60 5.8 ea. OS* 6G3AFTA 208/230-3-60 13.5 ea. OS* 6G4AFTA 460-3-60 6.0 ea. OS* 7G3AFTA 208/230-3-60 13.7 ea. OS* 7G4AFTA 460-3-60 6.2 ea. OS* 8G3AFTA 208/230-3-60 16.0 ea. OS* 8G4AFTA 460-3-60 7.8 ea. Unit w/ Evaporator Motor Unit Electric Heat Electric Heat HP FLA MCA MOP KW Amps MCA MOP 1/4 3.2 32.0 40 10 45.5 60.0 65 1/3 3.6 32.4 45 10 45.5 60.9 65 1/2 5.3 34.1 45 10 45.5 62.5 65 1/4 1.6 20.3 25 20 52.5 67.3 70 1/3 2.4 21.1 25 20 52.5 67.6 70 1/2 2.8 21.5 25 20 52.5 68.6 70 1/4 0.8 12.3 15 20 25.1 32.2 35 1/3 1.2 12.7 15 20 25.1 32.4 35 1/2 1.4 12.9 15 20 25.1 32.9 35 1/3 3.2 40.8 55 10 45.5 60.9 65 1/2 3.6 41.2 55 10 45.5 62.5 65 3/4 5.3 42.9 55 10 45.5 64.1 65 1/3 1.6 25.0 35 25 65.6 84.0 85 1/2 2.4 25.8 35 25 65.6 85.0 90 3/4 2.8 26.2 35 25 65.6 85.8 90 1/3 0.8 13.9 15 25 31.4 40.3 45 1/2 1.2 14.3 20 25 31.4 40.8 45 3/4 1.4 14.5 20 25 31.4 41.1 45 1/3 1.6 32.0 45 30 78.7 100.4 105 1/2 2.4 32.8 45 30 78.7 101.4 105 3/4 2.8 33.2 45 30 78.7 102.1 105 1/3 0.8 14.3 20 30 37.7 48.1 50 1/2 1.2 14.7 20 30 37.7 48.6 50 3/4 1.4 14.9 20 30 37.7 49.0 50 1/2 2.4 33.2 45 35 91.9 117.9 120 3/4 2.8 33.6 45 35 91.9 118.6 120 1 3.6 34.4 45 35 91.9 119.9 120 1/2 1.2 15.2 20 30 43.9 56.4 60 3/4 1.4 15.4 20 30 43.9 56.8 60 1 1.8 15.8 20 30 43.9 57.4 60 1/2 2.4 38.4 50 35 91.9 117.9 120 3/4 2.8 38.8 50 35 91.9 118.6 120 1 3.6 39.6 55 35 91.9 119.9 120 1/2 1.2 18.8 25 35 43.9 56.4 60 3/4 1.4 19.0 25 35 43.9 56.8 60 1 1.8 19.4 25 35 43.9 57.4 60 (a) Use Copper Conductors Only. (b) Values listed are typical and may vary dependent upon components utilized. * Either Water-Cooled or Air-Cooled Either Vertical (V) or Horizontal (H) Subject to change without notice. 23

Electrical Data - Section (a) (b) Tons Models Voltage 9 10 11 12 13.5 15 Compressor RLA OS* 9G3AFTA 208/230-3-60 15.6 ea. OS* 9G4AFTA 460-3-60 7.8 ea. OS* 10G3AFTA 208/230-3-60 19.0 ea. OS* 10G4AFTA 460-3-60 9.7 ea. OS* 11G3AFTA 208/230-3-60 22.4 ea. OS* 11G4AFTA 460-3-60 10.6 ea. OS* 12G3AFTA 208/230-3-60 23.2 ea. OS* 12G4AFTA 460-3-60 11.2 ea. OS* 13.5G3AFTA 208/230-3-60 25.0 ea. OS* 13.5G4AFTA 460-3-60 12.2 ea. OS* 15G3AFTA 208/230-3-60 29.5 ea. OS* 15G4AFTA 460-3-60 14.7 ea. Unit w/ Evaporator Motor Unit Electric Heat Electric Heat HP FLA MCA MOP KW Amps MCA MOP 1/2 2.4 37.5 50 45 118.1 150.6 155 3/4 2.8 37.9 50 45 118.1 151.4 155 1 3.6 38.7 50 45 118.1 152.6 155 1/2 1.2 18.8 25 45 56.5 72.1 75 3/4 1.4 19.0 25 45 56.5 72.5 75 1 1.8 19.4 25 45 56.6 73.1 75 3/4 2.8 45.6 60 50 131.2 167.8 170 1 3.6 46.4 65 50 131.2 169.0 170 1.5 4.8 47.6 65 50 131.2 171.0 175 3/4 1.4 23.2 30 50 62.8 80.4 85 1 1.8 23.6 30 50 62.8 81.0 85 1.5 2.4 24.2 30 50 62.8 82.0 85 3/4 2.8 53.2 75 55 144.3 184.1 185 1 3.6 54.0 75 55 144.3 185.4 190 1.5 4.8 55.2 75 55 144.3 187.4 190 3/4 1.4 25.3 35 55 69.0 88.1 90 1 1.8 25.7 35 55 69.0 88.8 90 1.5 2.4 26.3 35 55 69.0 89.8 90 1 3.6 55.8 75 60 157.5 201.9 205 1.5 4.8 57.0 80 60 157.5 203.9 205 1 1.8 27.0 35 60 75.3 96.6 100 1.5 2.4 27.6 35 60 75.3 97.6 100 1.5 4.8 61.1 85 65 170.6 220.3 225 2 6.2 62.5 85 65 170.6 221.0 225 1.5 2.4 29.9 40 65 81.6 105.5 110 2 3.1 30.6 40 65 81.6 105.9 110 1.5 4.8 71.2 100 70 183.7 236.6 240 2 6.2 72.6 100 70 183.7 237.4 240 1.5 2.4 35.5 50 70 87.9 113.4 115 2 3.1 36.2 50 70 87.9 113.8 115 (a) Use Copper Conductors Only. (b) Values listed are typical and may vary dependent upon components utilized. * Either Water-Cooled (W) or Air-Cooled (A) Either Vertical (V) or Horizontal (H) Subject to change without notice. 24

Electrical Data - Air-Cooled Condenser Section (a) (b) (c) OmegaAir Tons Model Voltage 1 1-1/2 2 3 4 (single) 4 (dual) 5 (single) 5 (dual) BCSP12G1ASTA 208/230-1-60 BCSP12G3ASTA 208/230-3-60 BCSP12G4ASTA 460-3-60 BCSP18G1ASTA 208/230-1-60 BCSP18G3ASTA 208/230-3-60 BCSP18G4ASTA 460-3-60 BC2G1ASTA 208/230-1-60 BC2G3ASTA 208/230-3-60 BC2G4ASTA 460-3-60 BC3G1ASTA 208/230-1-60 BC3G3ASTA 208/230-3-60 BC3G4ASTA 460-3-60 BC4G1ASTA 208/230-1-60 BC4G3ASTA 208/230-3-60 BC4G4ASTA 460-3-60 BC4G1ATA 208/230-1-60 BC4G3ATA 208/230-3-60 BC4G4ATA 460-3-60 BC5G1ASTA 208/230-1-60 BC5G3ASTA 208/230-3-60 BC5G4ASTA 460-3-60 BC5G1ATA 208/230-1-60 BC5G3ATA 208/230-3-60 BC5G4ATA 460-3-60 (a) Use Copper Conductors Only. (b) Values listed are typical and may vary dependent upon components utilized. (c) All motors 1725 RPM. Motors 5 HP inherently protected. Condenser Motor Unit HP FLA MCA MOP 1/2 3.8 4.8 5 3/4 5.8 7.3 10 1/2 2.2 2.8 5 3/4 3.2 4.0 5 1/2 1.3 1.6 5 3/4 1.5 1.9 5 1/2 3.8 4.8 5 3/4 5.8 7.3 10 1/2 2.2 2.8 5 3/4 3.2 4.0 5 1/2 1.3 1.6 5 3/4 1.5 1.9 5 3/4 5.8 7.3 10 1 7.0 8.8 15 3/4 3.2 4.0 5 1 3.4 4.3 5 3/4 1.5 1.9 5 1 1.6 2.0 5 1 7.0 8.8 15 1.5 9.4 11.8 20 1 3.4 4.3 5 1.5 5.0 6.3 10 1 1.6 2.0 5 1.5 2.4 3.0 5 1.5 9.4 11.8 20 2 13.7 17.1 30 1.5 5.0 6.3 10 2 6.5 8.1 10 1.5 2.4 3.0 5 2 3.1 3.9 5 1.5 9.4 11.8 20 2 13.7 17.1 30 1.5 5.0 6.3 10 2 6.5 8.1 10 1.5 2.4 3.0 5 2 3.1 3.9 5 2 13.7 17.1 30 3 18.0 22.5 40 2 6.5 8.1 10 3 8.8 11.0 15 2 3.1 3.9 5 3 4.2 5.3 10 2 13.7 17.1 30 3 18.0 22.5 40 2 6.5 8.1 10 3 8.8 11.0 15 2 3.1 3.9 5 3 4.2 5.3 10 Subject to change without notice. 25

Electrical Data - Air-Cooled Condenser Section (a) (b) (c) OmegaAir Tons Model Voltage 6 8 10 12 15 BC6G3ATA 208/230-3-60 BC6G4ATA 460-3-60 BC8G3ATA 208/230-3-60 BC8G4ATA 460-3-60 Condenser Motor Unit HP FLA MCA MOP 3 8.8 11.0 15 5 13.5 16.9 30 3 4.2 5.3 10 5 6.5 8.1 10 3 8.8 11.0 15 5 13.5 16.9 30 3 4.2 5.3 10 5 6.5 8.1 10 BC10G3ATA 208/230-3-60 7.5 18.0 22.5 40 BC10G4ATA 460-3-60 7.5 9.0 11.3 20 BC12G3ATA 208/230-3-60 7.5 18.0 22.5 40 BC12G4ATA 460-3-60 7.5 9.0 11.3 20 BC15G3ATA 208/230-3-60 10 28.0 35.0 60 BC15G4ATA 460-3-60 10 14.0 17.5 30 (a) Use Copper Conductors Only. (b) Values listed are typical and may vary dependent upon components utilized. (c) No motor upgrade. Drive set upgrade only. (d) All motors 1725 RPM. Motors 5 HP inherently protected. All 7.5 & 10 HP 1725 RPM with external overloads. Subject to change without notice. 26

Electrical Data - Air-Cooled Outdoor Propeller Fan Condenser OmegaAir Tons 1 1.5 2 2.5, 3 4 (single) 4 (dual) 5 (single) 5 (dual), 6 7, 8 9 10, 11 12 13.5 15 Condenser Fan Condenser Motor Unit Voltage Model Qty HP FLA MCA MOP PBC2G1ASTA 208/230-1-60 1.9 2.4 15 PBC2G3ASTA 1 208/230-3-60 (a) 1/3 1.9 2.4 15 PBC2G4ASTA 460-3-60 (a) 1 1.3 15 PBC3G1ASTA 208/230-1-60 1.9 2.4 15 PBC3G3ASTA 1 208/230-3-60 (a) 1/3 1.9 2.4 15 PBC3G4ASTA 460-3-60 (a) 1 1.3 15 PBC4G1ASTA 208/230-1-60 1.9 2.4 15 PBC4G3ASTA 1 208/230-3-60 (a) 1/3 1.9 2.4 15 PBC4G4ASTA 460-3-60 (a) 1 1.3 15 PBC5G1ASTA 208/230-1-60 1.9 2.4 15 PBC5G3ASTA 1 208/230-3-60 (a) 1/3 1.9 2.4 15 PBC5G4ASTA 460-3-60 (a) 1 1.3 15 PBC7G1ASTA 208/230-1-60 3.6 4.5 15 PBC7G3ASTA 1 208/230-3-60 1/2 2.8 3.5 15 PBC7G4ASTA 460-3-60 1.2 1.5 15 PBC7G1ATA 208/230-1-60 3.6 4.5 15 PBC7G3ATA 1 208/230-3-60 1/2 2.8 3.5 15 PBC7G4ATA 460-3-60 1.2 1.5 15 PBC10G1ASTA 208/230-1-60 3.6 ea 8.1 15 PBC10G3ASTA 2 208/230-3-60 1/2 ea 2.8 ea 6.3 15 PBC10G4ASTA 460-3-60 1.2 ea 2.7 15 PBC10G1ATA 208/230-1-60 (b) 3.6 ea 8.1 15 PBC10G3ATA 2 208/230-3-60 1/2 ea 2.8 ea 6.3 15 PBC10G4ATA 460-3-60 1.2 ea 2.7 15 PBC15G3ATA 208/230-3-60 2.8 ea 6.3 15 2 1/2 ea PBC15G4ATA 460-3-60 1.2 ea 2.7 15 PBC18G3ATA 208/230-3-60 2.8 ea 9.1 15 3 1/2 ea PBC18G4ATA 460-3-60 1.2 ea 3.9 15 PBC21G3ATA 208/230-3-60 2.8 ea 9.1 15 3 1/2 ea PBC21G4ATA 460-3-60 1.2 ea 3.9 15 PBC23G3ATA 208/230-3-60 2.8 ea 9.1 15 3 1/2 ea PBC23G4ATA 460-3-60 1.2 ea 3.9 15 PBC28G3ATA 208/230-3-60 2.8 ea 11.2 15 4 1/2 ea PBC28G4ATA 460-3-60 1.2 ea 5.1 15 PBC31G3ATA 208/230-3-60 2.8 ea 11.2 15 4 1/2 ea PBC31G4ATA 460-3-60 1.2 ea 5.1 15 (a) Single Phase motors on unit are wired for 3 phase operation. (b) Single phase is available for 5 ton system only. Subject to change without notice. 27

Water-Cooled Piping Arrangements 2-Way Single Circuit 2-Way Single Circuit with Bypass Condensing Coil 2-Way Valve Water In Water Out Condensing Coil 2-Way Valve Water In N.O. Solenoid Valve Water Out 3-Way Single Circuit 3-Way Valve Water In 2-Way Dual Circuit with Bypass 2-Way Valve Water In Condensing Coil Water Out Condensing Coil N.O. Solenoid Valve Water Out 2-Way Dual Circuit 2-Way Valve 2-Way Valve Water In Condensing Coil Condensing Coil Condensing Coil Condensing Coil 2-Way Valve 3-Way Dual Circuit 3-Way Valve 2-Way Valve Water Out Water In Water Out Condensing Coil Tons Water Connections Female Pipe Thread (FPT) 1 thru 4 3/4 5 thru 8 1 9 thru 12 1-1/4 13.5 & 15 1-1/2 Notes: 1. Standard valves are 2-way, 150 psig Water Reg Valves. 2. Optional valves: a. 2-way, 350 psig WRV b. 3-way, 150 psig WRV c. 3-way, 350 psig WRV d. 2-way, w/ N.O. solenoid bypass valve (150 psig only), 2-way valve in lieu of 3-way WRV e. Electronic Head Pressure Control Valves: 2-Way & 3-Way, 350 psig. 3. 3-way valve is placed only on lead circuit of dual-circuit units. 4. Water-cooled units are designed for 85 F EWT. If water temperature is below 75 or over 95, contact factory. 5. Nominal 3 GPM / Ton. 6. UCA select software is also available to verify performance at a range of conditions. 7. Valve settings have head pressure set at 235 psi. 8. Standard heat exchangers are counter flow co-axial type. 9. United CoolAir uses propylene glycol when testing all water-cooled units. When shipped, the water circuit may still have a little glycol inside. The water circuit should be flushed with water at the job site before being hooked up to the actual loop. Subject to change without notice. 28

Dimensions - Vertical Not To Scale Tons A B C D* E F G H I J K 1-3 31 31-5/8 12-1/2 5 or 7 52-1/2 8-1/2 42 64 9-1/2 24-3/4 20-1/8 4-8 31 29-1/4 20 5 or 7 57-7/8 11-3/8 48 72 10-1/2 39-1/8 16-1/2 9-15 31 26-7/8 25 5 or 7 61-1/2 13-5/8 72 78 12-7/16 51-1/8 15-1/16 *Extended filter rack to 18 or 20 inches with optional heat Subject to change without notice. 29

Dimensions - Horizontal B Air Path (Rear B Inlet Air and Path Bottom Supply) F G K A D C E I H J B Bottom Left Rear F Air Path (Rear F Inlet Air and Path Front Supply) F G K A J D C E H I B Top Left Rear T Air Path (Rear T Inlet Air and Path Top Supply) A J D C F E G H I K B Top Left Rear Not To Scale Tons A B C D E F* G H I J K 1-3 45 57 43 23-7/8 17-13/16 5 or 7 61 8-11/16 26 9-3/4 41 4-8 54 61 52 39-1/2 24 5 or 7 65 11-9/16 26 10-5/8 50 *Extended filter rack to 18 or 20 inches with optional heat Subject to change without notice. 30

Dimensions - Horizontal B Air Path (Rear B Air Inlet Path and Bottom Supply) F G N K A D C E I B H J Bottom L M Left Rear F Air Path F (Rear Air Inlet Path and Front Supply) A J D C F E N G H I K B L M Left Rear Top T Air Path (Rear T Air Inlet Path and Top Supply) A J D C F E N G H I K B L M Left Rear Not To Scale Top Tons A B C D E F* G H I J K L M N 9-15 70 42 68 59-1/2 25 5 or 7 46 13-11/16 30 12-1/2 66 4 21 25 *Extended filter rack to 18 or 20 inches with optional heat Subject to change without notice. 31

Indoor Ducted Condenser Dimensions (a) Note (b) Mounting rail height and duct flange 1 TYP TONS B C D Q R V X Y Z AA AB AC AD 1-1.5 SINGLE CIRCUIT 35 15 16 16 29 9 16 37 15 16 25 ¼ 4 15 16 12 6 ¼ 12 1 16 12 2 ¾ 1 ¼ 2 3 16 2-4 SINGLE CIRCUIT 5 SINGLE CIRCUIT 4-6 DUAL CIRCUIT 8-10 DUAL CIRCUIT 12-15 TRIPLE CIRCUIT PIPING OUTLET LOCATIONS 47 3 8 22 34 ¾ 48 ¾ 21 9 16 4 11 16 16 10 16 16 4 11 16 1 3 16 11 1 8 ROW 1 55 3 8 27 40 3 8 56 ¾ 27 ¼ 3 11 16 18 15 1 16 18 20 4 11 16 2 3 16 11 1 8 ROW 1 55 3 8 27 40 3 8 56 ¾ 27 ¼ 3 11 16 18 15 1 16 18 20 4 11 16 2 3 16 11 1 8 ROWS 1 & 2 70 5 8 29 45 15 16 72 1 16 32 1 8 5 5 8 30 14 7 16 20 24 3 ½ 1 ½ 11 1 8 ROWS 1 & 3 70 5 8 29 45 15 16 72 1 16 32 1 8 5 5 8 30 14 7 16 20 24 3 ½ 1 ½ 11 1 8 ROWS 1, 2 & 3 Due to product flexibility some options and configurations may not be shown. Contact the factory for specials. Subject to change without notice. 32

Indoor Ducted Condenser Sections Optional Air Paths Standard - Back Inlet / Back Discharge Back Inlet / Rear Discharge Side Inlet / Back Discharge Side Inlet / Rear Discharge Mirror Image Back Inlet / Back Discharge Mirror Image Back Inlet / Rear Discharge Mirror Image Side Inlet / Back Discharge Mirror Image Side Inlet / Rear Discharge Due to product flexibility some options and configurations may not be shown. Contact the factory for specials. Subject to change without notice. 33

Outdoor Propeller Fan Condenser Subject to change without notice. 34

Service Clearances - Plan View Note: Outdoor propeller fan condenser clearances: All sides 36", Above fan 72" Miscellaneous Application Data Voltage 208 / 230 460 Variation 187 / 253 414 / 504 Water-Cooled GPM / Ton (min./max.) 2.5 / 3.5 Leaving Water Temp (min./max) 60 / 115 Note: (a) Not all combinations may be valid (b) Dependent upon specific application, some additional refrigerant circuit considerations may be required. Condensate Drain Pipes: 3/4 IPS Subject to change without notice. 35

OmegaAir Section Basic Model Designation EXAMPLE: OS 1 W 2 V 3 3 4 G 5 3 6 ASF 7 T 8 A 9 10 10 - T 11 X 12 1. OS Outside Air Type 2. W Water-Cooled A Air-Cooled with Remote Condenser 3. V Vertical Configuration H Horizontal Configuration 4. Nominal Tons 1, 1.5, 2, 2.5, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13.5, 15 5. G Common to all 6. 1, 3, 4 Indicates Voltage 1 208-230V, 1 PH 60 Hz 3 208-230V, 3 PH 60 Hz 4 460V, 3 PH 60 Hz 7. ASF, ASD, AF, AD, ADF Quantity of Refrigerant Circuits/Compressor Type ASF Indicates 1 Circuit - Fixed Speed Compressor ASD Indicates 1 Circuit - Digital Compressor AF Indicates 2 Circuits - Fixed Speed Compressors (Both Circuits) AD Indicates 2 Circuits - Digital Compressors (Both Circuits) ADF Indicates 2 Circuits - Digital (Lead Circuit), Fixed Speed Compressor (Lag Circuit) 8. T Traditional Cabinet 9. A Refrigerant R-410a 10 2 thru 70 kw Electric Heat 11. -T, -F, -B Air Path Configuration -T Top Discharge -F Front Discharge -B Bottom Discharge 12. X Special Configuration Subject to change without notice. 36

Air-Cooled Indoor Ducted Condenser Basic Model Designation EXAMPLE: BC 1 3 2 G 3 3 4 AS 5 T 6 A 7 - X 8 1. BCSP Air-Cooled Condenser Section (1 or 1-1/2 Ton, Centrifugal) BC Air-Cooled Condenser Section (2 thru 15 Tons, Centrifugal) 2. Nominal Tons 1, 1.5, 2, 3, 4, 5, 6, 8, 10, 12, 15 3. G Common to all Common to all 4. 1, 3, 4 Indicates Voltage 1 208-230V, 1 PH 60 Hz 3 208-230V, 3 PH 60 Hz 4 460V, 3 PH 60 Hz 5. AS or A Quantity of Refrigerant Circuits AS Indicates 1 Circuit A Indicates 2 Circuits 6. T Traditional Cabinet 7. A Refrigerant R-410a Subject to change without notice. 37

Air-Cooled Outdoor Propeller Fan Condenser Basic Model Designation EXAMPLE: PBC 1 3 2 G 3 3 4 A 5 T 6 A 7 - X 8 1. PBC Air-Cooled Condenser Section 2. Model Size 2, 3, 4, 5, 6, 7, 10, 15, 18, 21, 23, 28, 31 3. G Common to all 4. 1, 3, 4 Power Supply 1 208-230V, 1 PH 60 Hz 3 208-230V, 3 PH 60 Hz 4 460V, 3 PH 60 Hz 5. AS, A Quantity of Refrigerant Circuits AS Indicates 1 Circuit A Indicates 2 Circuits 6. T Traditional Cabinet 7. A Refrigerant R-410a 8. X Special Configuration

Unique Solutions for All-Indoor HVAC Projects VertiCool Classic Vertical, 3-30 Ton VertiCool Aurora Vertical, 3-35 Tons VariCool VAV, 9-70 Tons VariCool EZ-Fit VAV, 12-90 Tons Alpha Aire 100 500 CFM Portable Cooling and Heating Units 3-30 Tons C13-Series Horizontal 2-10 Tons C-Series Horizontal 1-15 Tons Special Configuration Engineered to Order OmegaAir Horizontal and Vertical 100% Outside Air 150 3000 CFM Authorized Distributor: LIMITED WARRANTY United CoolAir Units are backed by a 1 year limited warranty on parts and a 5 year limited warranty on the compressor (labor not included). Maintenance items such as filters and belts are excluded under this limited warranty. FACTORY TESTED All units are functionally run tested before shipment to ensure a trouble-free start-up and unit commissioning. Industry proven components are used throughout to enhance system reliability and peace of mind. Scan to learn more about all of our products! 491 East Princess Street, York, PA 17403 Phone: 717-843-4311 Fax: 717-854-4462 email: uca@unitedcoolair.com web: www.unitedcoolair.com Copyright by United CoolAir Corporation 2017. All rights reserved. Manufacturer reserves the right to make changes without notice.