Flow Measurement SITRANS F C

Similar documents
Flow Measurement SITRANS F C

SITRANS FC. Flowmeter SITRANS FC410

Flow Measurement SITRANS F C

Level Measurement Continuous level measurement Ultrasonic transmitters

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M

Flow Measurement SITRANS F C. Flow sensor MASS 2100 DI 3 to DI 40. 4/180 Siemens FI

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

Micro Motion F-Series Coriolis Flow and Density Meters

Level Measurement Point level measurement - RF Capacitance switches

Level Measurement Point level measurement - RF Capacitance switches

Level Measurement Continuous level measurement - Capacitance transmitters

Micro Motion F-Series Flow and Density Meters

Micro Motion T-Series Coriolis Flow and Density Meters

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

Level Measurement Point level measurement - Vibrating switches

VersaFlow Coriolis 100 Mass Flow Sensor Specifications

SITRANS F M. Flow sensor MAG 1100 F 3/59

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel

OPTIMASS 2000 Technical Datasheet

OPTIMASS 3000 Technical Datasheet

SITRANS F flowmeters SITRANS F C

Flow Measurement SITRANS F M. Flow sensor MAG 1100 F 4/57

SITRANS F C. Flow sensor MC2 4/193. Overview

Micro Motion R-Series Coriolis Flow and Density Meters

Flow Measurement SITRANS F C

SITRANS F X SITRANS FX300 3/355

Micro Motion F-Series Flow and Density Meters

Micro Motion F-Series Coriolis Flow and Density Meters

SITRANS F flowmeters SITRANS F C SITRANS F C MC2 4/169. Overview

Point level measurement Capacitance switches

Micro Motion T-Series Straight-Tube Mass Flow and Density Meters. Product Data Sheet PS July 2001

Micro Motion ELITE Coriolis Flow and Density Meters

Flow Measurement SITRANS F M. Flow sensor MAG /85. Overview

Level Measurement. Continuous level measurement - Capacitance transmitters SITRANS LC500. 5/282 Siemens FI Overview.

Continuous level measurement Capacitance transmitters

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

SITRANS F flowmeters SITRANS F C MASSFLO MASS MC1. 4/146 Siemens FI Overview

Micro Motion ELITE Coriolis Flow and Density Meters

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

LCMass Series Mass Flow Sensor

Micro Motion ELITE Coriolis Flow and Density Meters

VersaFlow Vortex 100 Vortex Flow Meter Specifications

Micro Motion Model CNG050 Compressed Natural Gas Flowmeters

Micro Motion Model D and DL Coriolis Flow and Density Meters

Micro Motion ELITE Coriolis Flow and Density Meters

RHM40. Coriolis Mass Flow Meter for Demanding Applications. Features. Applications. Benefits

Flow Measurement SITRANS F C

Micro Motion ELITE High Capacity Coriolis Flow and Density Meters

RHM 12 - Standard 1 inch Coriolis Mass Flowmeter

RHM30. Coriolis Mass Flow Meter for Plant and Loading Flows. Features. Applications. Benefits

Level Limit Switch liquiphant FTL 365 / FTL 366

Level Measurement. Point level measurement Capacitance switches. Pointek CLS300 Standard. 5/42 Siemens FI Overview.

Pressure transmitter for marine applications MBS 33M

Level Measurement Point level measurement - RF Capacitance switches

Flow Measurement SITRANS F M. Flow sensor MAG 5100 W. 4/68 Siemens FI Overview

RHM015. Ultimate Performance Coriolis Mass Flow Meter for Critical Ultra Low Flow Applications. Features. Applications. Benefits

Micro Motion ELITE High Capacity Coriolis Flow and Density Meters

RHM 04 - Universal Coriolis Mass Flowmeter with particular Fast Response

Ultimate Low Flow Coriolis Mass Flowmeter

Food & beverage. Oil & gas. Water & waste water

Belt Scales Speed sensors

Rosemount 3051CFA Annubar Flowmeter

RHM04. Compact Coriolis Flow Sensor With Enhanced Performance. Features. Applications. Benefits

Level Measurement Continuous level measurement - Guided wave radar transmitters

RHM08. Versatile Coriolis Mass Flow Meter. Features. Applications. Benefits

RHM 015L/02L/03L/04L. Compact Low Flow Coriolis Flow Sensors

Technical Data Sheet PS , Rev C May Micro Motion R-Series Coriolis Flow and Density Meters

SITRANS F C MASSFLO Practical examples of ordering. MASS2100 & MASS6000 IP67 Compact mounted

SITRANS FX300 4/289. System Overview. Overview

SITRANS P measuring instruments for pressure

Level Measurement Continuous level measurement Guided wave radar transmitters

KROHNE 10/ Optimass 70 & 71 Single Tube Coriolis Mass Flowmeters for the Pharmaceutical Industry

Flow Measurement SITRANS F X SITRANS FX300 4/365

Micro Motion Model CNG050 Compressed Natural Gas Flowmeters

Resistance thermometer For sanitary applications Model TR22-B, for orbital welding

Promass Q for the process industry

JUMO dtrans p20. Process pressure transmitter. Brief description. Special features. Block diagram. Approvals/approval marks (see "Technical data")

Pressure transmitter for marine applications MBS 3100 and MBS 3150

Rosemount 3051T In-Line Pressure Transmitter

VLM20 In-line Vortex Flowmeter

Product Data Sheet PS February Model D and DT. Mass Flow and Density Sensors.

Rosemount 3051S Electronic Remote Sensor (ERS) System

Level Measurement Continuous level measurement - Radar transmitters

Belt Scales Speed sensors

Micro Motion ELITE Mass Flow and Density Meters

Flow Measurement SITRANS F US Clamp-on

Micro Motion 7827 Digital Viscosity Meter

RHM 015L/02L/03L/04L. Compact Low Flow Coriolis Flow Sensors

Level Measurement Continuous level measurement Radar transmitters

Micro Motion ELITE Mass Flow and Density Meters

Rosemount DP Level Transmitters and 1199 Diaphragm Seal Systems

RHM 04. Universal Coriolis Mass Flowmeter with particular Fast Response. Applications. Features. Advantages

Coriolis Flow Solutions for a Global Marketplace

Coriolis Mass Flowmeter for low flow measurements

KROHNE 10/ Optimass 70 & 71 Single Tube Coriolis Mass Flowmeters for the Chemical Industry

Diaphragm seal with sterile connection With union nut (milk thread fitting) Models , , and

Metal tube variable area flowmeter for gases, liquids and steam

RHM 08. One of the most popular Rheonik Mass Flowmeter serving thousands of worldwide applications. Applications. Advantages.

RHM 03 a1 - (low stress in welds and increased wall thickness against abrasion) RHM bar APPLICATIONS. Batching Dosing. Injections Filling

Transcription:

Overview Benefits It is compact and light, fitting neatly into dense piping arrangements Effective separation of measurement from plant vibration Reliable measurements due to high signal to noise ratio Short overall length; easy drop-in replacement into most existing installations Direct connection to host with high-speed Modbus simplifies machine or skid construction and set-up. Modbus RS485 RTU allows simple and easy integration with all Modbus masters with fast update rate of process values The compact flowmeter SITRANS FC410 can be ordered for industrial, hygienic or NAMUR service. Intended for integration into OEM skids, machines or pre-assembled plant systems, the flowmeter is based on the latest developments within digital signal processing technology - engineered for high measuring performance: Fast response to rapid changes in flow Fast dosing applications with control in host system High immunity against process noise High turndown ratio of flowrates Suitable for liquid and gas service Easy to install, commission and maintain With all global marine approvals the FC410 is ideal for integration in ship fuel efficiency and environmental measurement systems as well as bunkering solutions. The FCT010 transmitter delivers true multi-parameter measurements i.e. massflow, density, temperature FC410 is available with Modbus RTU (RS 485) multi-drop serial communication. The flowmeter is supplied with SensorFlash, a micro SD card containing all relevant certificates. The SITRANS FC410 flowmeter system consists of a SITRANS FCS400 sensor and a SITRANS FCT010 transmitter always compact mounted. Siemens FI 01 2018 /179

Technical specifications Sizes DN 15 (½") DN 25 (1") DN 50 (2") DN 80 (") DN 100 (4") DN 150 (6") Accuracy ±0.10% Repeatability ±0.05% Flow range (water @ 1 bar pressure loss) DN 15 700 kg/h (8 157 lb/h) DN 25 11 500 kg/h (25 5 lb/h)) DN 50 52 000 kg/h (114 640 lb/h) DN 80 16 000 kg/h (00 000 lb/h) DN 100 285 800 kg (60 081 lb/h) DN 150 459 200 kg/h (1 012 62 lb/h) Power supply 24 V DC ± 20 %; 110 ma Weight 4.6... 207 kg Material Sensor - Measuring tubes 16L stainless steel or Hastelloy C22 (DN 15... 50) - Enclosure 04 stainless steel Transmitter Aluminum with corrosion-resistant coating Enclosure rating IP67 Pressure ratings Measuring tubes - 16L 100 bar (1450 psi) - Hastelloy C22 (DN 15 to 50) 160 bar (221 psi) Sensor enclosure 20 bar (DN 15, DN 25) 17 bar (DN 50, DN 80) 0 bar (DN 100, DN 150) Sensor enclosure burst pressure >160 bar (all sizes) Temperature ratings Process medium - DN 15... DN 80-50... +200 C (-58... +92 F) - DN 100 and DN 150-50... +205 C (-58... +400 F) Ambient -40... +60 C (-40... +140 F) Process connections Flanges EN 1092-1 B1, EN 1092-1 D, ANSI/ASME B16.5, JIS B 2220, DIN 11864-2 Pipe threads ASME B1.20 (NPT), ISO228-1 G (BSPP), VCO Quick-connect Hygienic threads DIN 11851, DIN 11864-1A, ISO 285, SMS 1145 Hygienic clamps DIN 11864-A, DIN 2676, ISO 2852 Approvals Hazardous area ATEX, IECEx, EAC Ex, FM, NEPSI, CSA, ccsa us, INMETRO (installed with flameproof conduit) Pressure equipment PED, CRN Hygienic A, EHEDG Marine 1) Germanischer Lloyd/det Norske Veritas, Bureau Veritas, Lloyds of London, American Bureau of Shipping, RINA (Italy) NAMUR NAMUR-compliant (e.g. NE 21, NE 41 and NE 12) Communication Modbus RS 485 RTU EMC performance Emission EN 55011/CISPR-11 (Class B) Immunity EN/IEC 6126-1 (Industry) Mechanical load 18 to 400 Hz random The flow meter will mechanically tolerate.17 g RMS in all directions. Flow accuracy cannot be guaranteed under all conditions. 1) Does not apply for DN 100 and DN 150 sizes. /180 Siemens FI 01 2018

Article No. Ord. code SITRANS FC410 Digital coriolis flowmeter 7 ME 4 6 1 1 - with SITRANS FCS400 Standard flow sensor with hygienic and flange/pipe thread connections and compact mounting with FCT010 transmitter Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Sensor size, connection size DN 15, DN 6 (½", ¼") E DN 15, DN 10 (½", /8") F DN 15, DN 15 (½", ½") G DN 15, DN 20 (½", ¾") H DN 15, DN 25 (½", 1") J DN 25, DN 25 (1", 1") L DN 25, DN 2 (1", 1¼") M DN 25, DN 40 (1", 1½") N DN 50, DN 40 (2", 1½") 4 B DN 50, DN 50 (2", 2") 4 C DN 80, DN 65 (", 2½") 4 J DN 80, DN 80 (", ") 4 K DN 80, DN 100 (", 4") 4 L DN 100, DN 80 (4", ") 5 M DN 100, DN 100 (4", 4") 5 N DN 100, DN 150 (4", 6") 5 Q DN 150, DN 100 (6", 4") 6 D DN 150, DN 150 (6", 6") 6 F DN 150, DN 200 (6", 8") 6 H Process connection EN 1092-1 B1, PN 16 A 0 EN 1092-1 B1, PN 40 A 1 EN 1092-1 B1, PN 6 A 2 EN 1092-1 B1, PN 100 A EN 1092-1 B1, PN 160 B 1 EN 1092-1 D NUT, PN 40 A 5 EN 1092-1 D NUT, PN 6 A 6 EN 1092-1 D NUT, PN 100 A 7 EN 1092-1 D NUT, PN 160 A 8 ANSI B16.5-2009, class 150 D 1 ANSI B16.5-2009, class 00 D 2 ANSI B16.5-2009, class 600 D ANSI B16.5-2009, class 900 D 4 ISO228-1 G pipe thread E 1 ASME B1.20.1 NPT pipe thread E DIN 11851 hygienic screwed F 1 DIN 2676 hygienic Tri-Clamp G 1 DIN 11864-1 GS Form A Row A H 1 DIN 11864-2 BF Form A Row A H 2 DIN 11864- BKS Form A Row A H ISO 2852 hygienic clamped J 1 ISO 285 hygienic screwed J 5 SMS 1145 hygienic screwed K 1 12-VCO-4 quick connect K 5 JIS B2200:2004/10K L 2 JIS B2220:2004/20K L 4 JIS B2220:2004/40K L 6 JIS B2220:2004/6K L 7 Wetted parts material AISI 16L/W1.445/W1.4404 (100 barg max.) 1 Hastelloy C22 (only for 7ME461, DN 15... 50) Article No. Ord. code SITRANS FC410 Digital coriolis flowmeter 7 ME 4 6 1 1 - with SITRANS FCS400 Standard flow sensor with hygienic and flange/pipe thread connections and compact mounting with FCT010 transmitter Calibration/Accuracy class (liquids) 0.1 % flow, 5 kg/m³ density 1 DN 15... DN 80: 4 0.1 % flow, 0.5 kg/m³ density DN 100 and DN 150: 0.1 % flow, 1.0 kg/m³ density Mounting style, transmitter housing and material Compact, IP67, Aluminum D Ex approval (depending on variant) Non-Ex A ATEX II 2GD C IECEx GDb F FM, Class 1, Div 1 H ccsa us L CSA, Class 1, Zone 1 M NEPSI N INMETRO P KCs Q EAC U Local User Interface Blind 1 Further designs Cable glands Metric, no glands Metric, plastic Metric, brass/ni plated Metric, stainless steel NPT, no glands NPT, Plastic NPT, brass/ni plated NPT, stainless steel Integral M12 socket Sofware functions and CT approvals Standard I/O configuration Ch1 Modbus RTU RS 485 I/O configuration Ch2, Ch and Ch4 A01 A02 A05 A06 A11 A12 A15 A16 A20 B11 E14 F00 Siemens FI 01 2018 /181

Add-on options and accessories Certificates Pressure test certificate CRN C01 Pressure test certificate PED C02 Material certificate EN 10204-.1 C05 Welding inspection report C07 Factory certificate to EN 10204 2.1 C10 Factory certificate to EN 10204 2.2 C11 NACE MR0175 (FCS400, DN 100 and DN 150) C16 Cleaned for oil and grease C50 Cable 1) L50 5 m (16.4 ft), standard with M12 connectors fitted L51 5 m (16.4 ft), standard L52 10 m (2.8 ft) standard with M12 connectors fitted L55 10 m (2.8 ft), standard L56 25 m (82 ft), standard with M12 connectors fitted L59 25 m (82 ft), standard L60 50 m (164 ft), standard with M12 connectors fitted L6 50 m (164 ft), standard L64 75 m (246 ft), standard with M12 connectors fitted L67 75 m (246 ft), standard L68 150 m (492 ft), standard with M12 connectors fitted L71 (depending on variant) 150 m (492 ft), standard (depending on variant) L72 Additional data code(s) and plain text. Tag name Tag name plate, 16L stainless steel Customer selected calibration Multi-point high, 5 flows x 2 passes, 10... 100 % of Q nom Multi-point high, 10 flows x 1 pass, 10... 100 % of Q nom Multi-point low, 5 flows x 2 passes, 2... 20% of Q nom Multi-point, 5 flows x 2 passes, 5... 50% of Q nom Multi-point low, 10 flows x 1 pass, 2... 20% of Q nom Multi-point, 10 flows x 1 pass, 5... 50% of Q nom Y17 Y61 Y6 Y69 Y71 Y72 Y7 1) M12 versions of cable have a connector at both ends. We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 10/11 in the appendix. Operating instructions for SITRANS FC410 Description English for firmware up to V.x for firmware V 4.0 and onwards German for firmware up to V.x for firmware V 4.0 and onwards Article No. A5E120874 A5E9789214 A5E124885 TBD All literature is available to download for free, in a range of languages, at www.siemens.com/processinstrumentation/documentation /182 Siemens FI 01 2018

Article No. Ord. code SITRANS FC410 Digital coriolis flowmeter with SITRANS FCS400 Flow sensor Hygienic version with Ra < 0.8 m, A approved, and compact mounting with FCT010 transmitter Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Sensor size, connection size DN 15, DN 10 (½", /8") DN 15, DN 15 (½", ½") DN 15, DN 20 (½", ¾") DN 15, DN 25 (½", 1") DN 25, DN 25 (1", 1") DN 25, DN 2 (1", 1¼") DN 25, DN 40 (1", 1½") DN 50, DN 40 (2", 1½") DN 50, DN 50 (2", 2") DN 80, DN 65 (", 2½") DN 80, DN 80 (", ") Process connection 7 ME 4 6 2 1 - F G H J L M N 4 B 4 C 4 J 4 K Further designs Cable glands Metric, no glands Metric, plastic Metric, brass/ni plated Metric, stainless steel NPT, no glands NPT, plastic NPT, brass/ni plated NPT, stainless steel Integral M12 socket Sofware functions and CT approvals Standard I/O configuration Ch1 Modbus RTU RS 485 I/O configuration Ch2, Ch and Ch4 A01 A02 A05 A06 A11 A12 A15 A16 A20 B11 E14 F00 DIN 11851 0.8 µm hygienic screwed F 1 DIN 2676 0.8 µm hygienic Tri-Clamp G 1 DIN 11864-1 GS Form A Row A H 1 DIN 11864-2 BF Form A Row A H 2 DIN 11864- BKS Form A Row A H ISO 2852 0.8 µm hygienic clamped J 1 ISO 285 0.8 µm hygienic screwed J 5 Wetted parts material AISI 16L/1.445 (40 bar max.) 1 Calibration/Accuracy class (liquids) 0.1 % flow, 5 kg/m³ density 1 0.1 % flow, 0.5 kg/m³ density 4 Standard fraction calibration 8 Mounting style, transmitter housing and material Compact, IP67, aluminum D Ex approval (depending on variant) Non-Ex ATEX II 2GD IECEx GDb FM, Class 1, Div 1 ccsa us CSA, Class 1, Zone 1 NEPSI INMETRO KCs EAC A C F H L M N P Q U Local User Interface Blind 1 Siemens FI 01 2018 /18

Add-on options and accessories Certificates Pressure test certificate CRN C01 Pressure test certificate PED C02 Material certificate EN 10204-.1 C05 Welding inspection report C07 Factory certificate to EN 10204 2.1 C10 Factory certificate to EN 10204 2.2 C11 Cleaned for oil and grease C50 Cable 1) L50 5 m (16.4 ft), standard with M12 connectors fitted L51 5 m (16.4 ft), standard L52 10 m (2.8 ft) standard with M12 connectors fitted L55 10 m (2.8 ft), standard L56 25 m (82 ft), standard with M12 connectors fitted L59 25 m (82 ft), standard L60 50 m (164 ft), standard with M12 connectors fitted L6 50 m (164 ft), standard L64 75 m (246 ft), standard with M12 connectors fitted L67 75 m (246 ft), standard L68 150 m (492 ft), standard with M12 connectors fitted L71 (depending on variant) 150 m (492 ft), standard (depending on variant) L72 Additional data code(s) and plain text. Tag name Tag name plate, stainless steel Customer selected calibration Multi-point high, 5 flows x 2 passes, 10... 100 % of Q nom Multi-point high, 10 flows x 1 pass, 10... 100 % of Q nom Multi-point low, 5 flows x 2 passes, 2... 20% of Q nom Multi-point, 5 flows x 2 passes, 5... 50% of Q nom Multi-point low, 10 flows x 1 pass, 2... 20% of Q nom Multi-point, 10 flows x 1 pass, 5... 50% of Q nom Y17 Y61 Y6 Y69 Y71 Y72 Y7 1) M12 versions of cable have a connector at both ends. Operating instructions for SITRANS FC410 Description Article No. English for firmware up to V.x A5E120874 for firmware V 4.0 and onwards A5E9789214 German for firmware up to V.x A5E124885 for firmware V 4.0 and onwards TBD All literature is available to download for free, in a range of languages, at www.siemens.com/processinstrumentation/documentation /184 Siemens FI 01 2018

Article No. Ord. code SITRANS FC410 Digital coriolis flowmeter 7 ME 4 7 1 1 - with SITRANS FCS400 NAMUR complient flow sensor with flange/pipe thread connections and compact mounting with FCT010 transmitter (V.1 only) Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Sensor size, Connection size DN 15, DN 6 (½", ¼") E DN 15, DN 10 (½", /8") F DN 15, DN 15 (½", ½") G DN 15, DN 20 (½", ¾") H DN 15, DN 25 (½", 1") J DN 25, DN 25 (1", 1") L DN 25, DN 2 (1", 1¼") M DN 25, DN 40 (1", 1½") N DN 50, DN 40 (2", 1½") 4 B DN 50, DN 50 (2", 2") 4 C DN 80, DN 65 (", 2½") 4 J DN 80, DN 80 (", ") 4 K DN 80, DN 100 (", 4") 4 L Process connection EN1092-1 B1, PN 16 A 0 EN1092-1 B1, PN 40 A 1 EN1092-1 B1, PN 6 A 2 EN1092-1 B1, PN 100 A EN1092-1 B1, PN 160 B 1 EN1092-1 D, PN 40 A 5 EN1092-1 D, PN 6 A 6 EN1092-1 D, PN 100 A 7 EN1092-1 D, PN 160 A 8 ANSI B16.5, RF, class 150 D 1 ANSI B16.5, RF, class 00 D 2 ANSI B16.5, RF, class 600 D ANSI B16.5, RF, class 900 D 4 ISO228-1 G pipe thread E 1 ASME B1.20.1 NPT pipe thread E DIN 11851 Hygienic screwed F 1 DIN 2676-C (inch) Hygienic clamped G 1 DIN 11864-1 GS Form A Row A H 1 DIN 11864-2 BF Form A Row A H 2 DIN 11864- BKS Form A Row A H ISO 2852 Hygienic clamped J 1 ISO 285 Hygienic screwed J 5 SMS 1145 Hygienic screwed K 1 Swagelok Quick Connect K 5 JIS B2200/10K L 2 JIS B2200/20K L 4 JIS B2200/40K L 6 JIS B2200/6K L 7 Wetted parts material AISI 16L/W1.445/W1.4404 (100 barg max.) 1 Hastelloy C22 Calibration/Accuracy class (liquids) 0.1 % flow, 5 kg/m³ density 1 0.1 % flow, 0.5 kg/m³ density 4 Mounting style, transmitter housing and material Compact, IP67, aluminum D Article No. Ord. code SITRANS FC410 Digital coriolis flowmeter 7 ME 4 7 1 1 - with SITRANS FCS400 NAMUR complient flow sensor with flange/pipe thread connections and compact mounting with FCT010 transmitter (V.1 only) Ex approval Non-Ex A ATEX II 2GD C IECEx GDb F FM, Class 1, Div 1 H NEPSI N INMETRO P KCs Q EAC U Local User Interface Blind 1 Further designs Cable glands Metric, no glands Metric, plastic Metric, brass/ni plated Metric, stainless steel NPT, no glands NPT, plastic NPT, brass/ni plated NPT, stainless steel Sofware functions and CT approvals Standard I/O configuration Ch1 Modbus RTU RS 485 I/O configuration Ch2, Ch and Ch4 A01 A02 A05 A06 A11 A12 A15 A16 B11 E14 F00 Siemens FI 01 2018 /185

Add-on options and accessories Certificates Pressure test certificate CRN C01 Pressure test certificate PED C02 Material certificate EN 10204-.1 C05 Welding inspection report C07 Factory certificate to EN 10204 2.1 C10 Factory certificate to EN 10204 2.2 C11 Cleaned for oil and grease C50 Cable 1) L50 5 m (16.4 ft), standard with M12 connectors fitted L51 5 m (16.4 ft), standard L52 10 m (2.8 ft) standard with M12 connectors fitted L55 10 m (2.8 ft), standard L56 25 m (82 ft), standard with M12 connectors fitted L59 25 m (82 ft), standard L60 50 m (164 ft), standard with M12 connectors fitted L6 50 m (164 ft), standard L64 75 m (246 ft), standard with M12 connectors fitted L67 75 m (246 ft), standard L68 150 m (492 ft), standard with M12 connectors fitted L71 150 m (492 ft), standard L72 Additional data code(s) and plain text. Tag name Tag name plate, stainless steel Customer selected calibration Multi-point high, 5 flows x 2 passes, 10... 100 % of Q nom Multi-point high, 10 flows x 1 pass, 10... 100 % of Q nom Multi-point low, 5 flows x 2 passes, 2... 20% of Q nom Multi-point, 5 flows x 2 passes, 5... 50% of Q nom Multi-point low, 10 flows x 1 pass, 2... 20% of Q nom Multi-point, 10 flows x 1 pass, 5... 50% of Q nom Y17 Y61 Y6 Y69 Y71 Y72 Y7 1) M12 versions of cable have a connector at both ends. Operating instructions for SITRANS FC410 Description Article No. English A5E120874 German A5E124885 All literature is available to download for free, in a range of languages, at www.siemens.com/processinstrumentation/documentation /186 Siemens FI 01 2018