RELIEF VALVES Remote Control / Direct Type Pilot Operated / Solenoid Controlled

Similar documents
BST / BSG-03 / 06 / 10 Threaded Connections / Sub-plate Mounting. Specifications / Model Number Designation. Max. Flow L/min (U.S.GPM) Double Sol.

Solenoid Controlled Relief Valves

Low Noise Type Solenoid Controlled Relief Valves

Hydraulic Fluids. Note: For use with hydraulic fluids other than those listed above, please consult your Yuken representatives in advance.

PRESSURE REDUCING AND RELIEVING VALVES

Pressure Reducing and Relieving Valves

UNLOADING RELIEF VALVES

PRESSURE REDUCING AND RELIEVING VALVES

SHUT-OFF TYPE SOLENOID OPERATED DIRECTIONAL VALVES DSPC/DSPG-01/03(1/8,

EManually Operated Directional Valves

Max. Operating Pressure Kgf/cm 2. F- YB T -01 -F Max. Operating Design Pressure Kgf/cm 2 Number. Panel. Mounting

EManually Operated Directional Valves

Vent Connection. Pres. Adj. Range BT BG * ~ BG F- B T -03 P -V -32.

"G" SERIES SHOCKLESS TYPE SOLENOID OPERATED DIRECTIONAL VALVES G-DSG-01/03 (1/8, 3/8) "G" SERIES SHOCKLESS TYPE

01 SERIES MODULAR VALVES. Pub. EC-1402

High Pressure, High Flow Rate Modular Valves

EMechanically Operated Directional Valves

Series Proportional Electro-Hydraulic Controls

06 SERIES MODULAR VALVES. Pub. EC-1404

EH SERIES PROPORTIONAL ELECTRO-HYDRAULIC CONTROL VALVES

03 SERIES. General Information Mounting Surface : ISO 4401-AC-05-4-A, CETOP-5, NFPA-DO2 Up to 25 MPa (3630 PSI), 70 L /min (18.5 U.S.

Proportional Electro-Hydraulic Pilot Relief Valves

FLOW CONTROLS. Maximum Flow U.S.GPM Maximum Operating Pressure MPa (PSI) Graphic Symbols. Page. Valve Type.

Series Shockless Type Solenoid Controlled Pilot Operated Directional Valves

Proportional Electro-Hydraulic Flow Control and Relief Valves

50T,150T,250F SERIES Fixed Displacement-Single, Double, Combination 3

Restrictors / One Way Restrictors

50T,150T,250F SERIES Fixed Displacement-Single, Double, Combination

" " Series Variable Displacement Piston Pumps

"AR" SERIES PISTON PUMPS. Variable Displacement-Single Pumps Pressure Compensator Type,AR16 / AR22-FR01

10 SERIES MODULAR VALVES. Pub. EC-1405

DIRECTIONAL CONTROLS. Pilot Operated Directional Valves. Specifications

High Response Type Proportional Electro-Hydraulic Directional and Flow Control Valves

"AR" SERIES PISTON PUMPS. Variable Displacement-Single Pumps Pressure Compensator Type,AR16 / AR22- FR01 3

Pilot Operated Flow Control Valves / Pilot Operated Flow Control and Check Valves

EMulti Purpose Control Valves

These valves may be used to manually shift the spool position and change the direction of oil flow *2 1.8

PROPORTIONAL ELECTRO-HYDRAULIC CONTROLS

Throttle Modules / Throttle and Check Modules

Direct Operated Type Directional and Flow Control Valves

PROPORTIONAL ELECTRO-HYDRAULIC CONTROLS

E SERIES. Proportional Electro-Hydraulic Relief Valves. Specification. Model Number Designation. Attachment Mounting Bolts

Proportional Electro-Hydraulic Flow Control (and Check) Valves

Poppet Type Directional Valves

PROPORTIONAL ELECTRO-HYDRAULIC CONTOROLS

"A" Series Variable Displacement Piston Pumps Single Pump, Pressure Compensator Type

Note: For use with hydraulic fluids other than those listed above, please consult Yuken representative in advance.

" " Series Variable Displacement Piston Pumps

AR Series Variable Displacement Piston Pumps. AR Series Variable Displacement Piston Pumps. AR Series Variable Displacement Piston Pumps

A Series Variable Displacement Piston Pumps

High Pressure, High Flow Rate Modular Valves

Modular Valves. Ratings

Proportional Electro-Hydraulic Directional and Flow Control Valves

10 SERIES MODULAR VALVES

E SERIES. Proportional Electro-Hydraulic Relief Valves. Specification. Model Number Designation. Attachment Mounting Bolts

Max. Operating Pressure Kgf/cm 2

Directional Controls

Flow Control Valves / Flow Control and Check Valves

VANE PUMPS. Output Flow at 1200 r/min at No-Load U.S.GPM Maximum Operating Pressure MPa (PSI) Graphic Symbols.

ISD SO-NB-G105 SO-NB-G85 SO-NB-P46 PV2R1-* - * -RAA-42/4290 PV2R2-* - * -RAA-41/4190 PV2R3-* - * -RAA-31/3190 PV2R4-* - * -RAA-30/3090

Max. Reversed Free Flow. Max. Operating. Pressure MPa (PSI) Fine Feed 20 (5.3) 14 (2030) 40 (10.6) ( ) 40 (10.6) (

Directional Control Valves. Features. Application. Operation

Directional Control Valves Series D81V. General Description. Operation. Features. Specifications

Directional Control Valves. General Description. Operation. Features

Directional Controls

VARIABLE DISPLACEMENT PISTON PUMPS

A Series Variable Displacement Piston Pumps. A16 Type performance characteristics A16 Type Noise level characteristics.

Proportional Electro-Hydraulic Relieving and Reducing Valves

AR Series Variable Displacement Piston Pumps. [Comparison of AR16 with A16 ] A16,32 Design 188. AR16,22 Design 130. Ratio of Mass (AR16/A16) 74%

Variable Displacement Piston Pumps

"PV11R" SERIES Fixed Displacement- Single PV11R10/PV11R20

MODULES. Maximum Flow U.S.GPM. Max. Operating Pressure MPa (PSI) L/min. 005 Series 25 (3630) Modular Valves. 01 Series 31.

5.2 to 79 gpm 3000, 3600, 5000 psi

NDR Series Rotor Pack

ARL1 Series Piston Pumps. ARL1 Series Piston Pumps. Geometric Displacement. Maximum cm 3 /rev

5 Port Solenoid Valve

Directional Control Valves. General Description. Operation. Features

Directional Control Valves. General Description. Operation. Features

Min. Metered Flow Capacity L/min. Max. Oper. Pressure Kgf/cm (0.04)* F- FC G N -11 H01. Max. Metered Flow Capacity L/min.

Directional Control Valves. Application. Features. Operation

EHBG-03 EHBG-06 EHBG-10. Refer to Model No. Designation. 2% or Less(1%) 1% or Less *2. Refer to frequency Response on page V DC

Modular Throttle Valve MST MT MTC MCT Solenoid Operated Throttle Valve Throttle Valve Throttle and Check Valve Counter Restrictors Valve

Series Variable Displacement Piston Pump

PISTON PUMPS. A3H Series High Pressure Variable Displacement Piston Pumps. Features. A3H Series Variable Displacement Piston Pumps.

5 Port Solenoid Valve

Solenoid directional valves type DPHI, DPHU

Pilot Operated Pressure Relief Valve Series R5V (Denison)

Publ. 3-EN 2950-A. DENISON HYDRAULICS Pressure Relief Valve R6V

Directional Control Valves. Application. Features. Operation.

"A" Series Piston Pumps Variable Displacement-Single Pumps Electro-Hydraulic Proportional Pressure & Flow Control. Type

5 Port Solenoid Valve

Model (kg) CIT CRG-06 CIT : CIT CRG-10 CIT : CIT CIT

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

Max. Reversed Free Flow L/min

Series VC Direct Operated 2 Port Solenoid Valve for Oil. Series VCL VX VN VQ VDW VC LV PA

Differential Lock Valve

Pump Safety Block Model DBA... / DBAW, Series 1X

Directional Control Valves

Hydraulics 1. Directional Control Valves Series D1M. Features. Application. Operation. D1MW Solenoid Operated Free Lead Wire

Bankable Control Valves

Transcription:

RELIEF VALVES Remote ontrol / Direct ype ilot Operated / Solenoid ontrolled Up to 5 Ma (3630 SI), 0 L /m in (06 U.S.GM) ub. E-00 Remote ontrol Relief Valves... age 3 his valve is used as a remote control valve for pilot operated type pressure control valves. Direct ype Relief Valves...... age 6 his valve is used in a hydraulic circuit to prevent damage due to over pressure and to adjust the maximum circuit pressure of small capacity. ilot Operated Relief Valves... age 9 hese valves protect the hydraulic system from excessive pressure, and can be used to maintain constant pressure in a hydraulic system. Remote control and unloading are permitted by using vent circuits. Low Noise ype ilot Operated Relief Valves... age 6 ilot operated relief valves here have been particularly develop-ed as low-noise types. Able to protect pumps and control valves against excessive pressures, they are used to control the pressure in the hydraulic system to a constant level. Remote control and unloading are permitted by using vent circuits. Solenoid ontrolled Relief Valves... age 0 hese valves are a combination of a pilot operated relief valve and a solenoid operated directional valve. iping between the two is eliminated as the solenoid valve is directly mounted on the relief valve and connected with the relief valve vent. ump pressure may be unloaded remotely by an electrical signal to the solenoid, or by connecting pilot relief valves to the solenoid valve ports. a "A" "B" b Low Noise ype Solenoid ontrolled Relief Valves... age 3 he low-noise solenoid controlled relief valve is a combination of a low-noise type pilot operated relief valve and a solenoid operated directional valve. It is used for no-load pump operation by using electric signals or, together with a remote control relief valve, for two or three pressure control of the hydraulic system. a "A" "B" b No.

RELIEF VALVES Remote ontrol / Direct ype ilot Operated / Solenoid ontrolled Instructions / Hydraulic Fluids AUION When making replacement of seals or solenoid assemblies, please do it carefully after reading through the relevant instructions in the Operator's Manual. Instructions o adjust the pressure, loosen the lock nut and turn the handle slowly clockwise for higher pressures or anti-clockwise for lower pressures. After adjustments, do not forget to tighten the lock nut. iping of the tank line should not be connected to any tank line of the other valves, but connected directly to the tank. Hydraulic Fluids Fluid ypes Any type of hydraulic fluids listed in the table below can be used. etroleum base oils Sy nthetic fluids Water containing fluids Use fluids equivalent to ISO VG 3 or VG 46. Use phosphate ester or poly ol ester fluid. When phosphate ester fluid is used, prefix "F-" to the model number because the special seals (fluororubber) are required to be used. Use water-gly col fluid. Note: For use with hy draulic fluids other than those listed above, please consult y our Yuken representatives in advance. Recommended Viscosity and Oil emperatures Viscosity ranging between 5-0 mm /s (77-800 SSU). Oil temperatures between -5/+70 (5-58 F). Use hydraulic fluids which satisfy the recommended viscosity and oil temperatures given above. ontrol of ontamination Due caution must be paid to maintaining control over contamination of the hydraulic fluids which may otherwise lead to breakdowns and shorten the life of the valves. lease maintain the degree of contamination within NAS 638-Grade. Use 5 µm or finer line filter. No.

Remote ontrol Relief Valves D / DG-0 hreaded onnections / Specifications / Model Number Designation / others Specifications hreaded onnection D-0- Mounting DG-0- Max. Operating res. Ma (SI) 5 (3630) Approx. Mass kg (lbs.) D type DG type.6 (3.5).4 (3.) Model Number Designation F- D Special Seals Series Number y pe of Mounting -0 Valve - Design Number Design Standards F: Special Seals for hosphate Ester ype Fluids (Om it if not required) D: Rem ote ontrol Relief Valves : hreaded onnection G: Mounting 0 None: Japanese Std. "JIS" 80: European Design Std. 90: N. American Design Std. None: Japanese Std. "JIS" and European Design Std. 90: N. American Design Std. Instructions is limited by collars fitted. If a working pressure cannot be attained, remove some collars. One collar is equivalent to 0 Ma (4 SI). If the internal volume of the vent line is too large, chattering is likely to occur. Graphic Symbol Attachment Mounting bolts Valve Model Socket Head ap Screw Qty. Numbers Japanese Std. "JIS" and European Design Std. N. American Design Std. DG-0 M5 45 Lg. No.0-4UN -3/4 Lg. 4 Valve Model Numbers Japanese Standard "JIS" European Design Standard N. American Design Standard hread Approx. Mass kg (lbs.) DG-0 DGM-0-0 Rc /4 DGM-0-080 /4 BS.F DGM-0-090 /4 N 0.7 (.5) s are available. Specify the sub-plate model number from the table above. When sub-plates are not used, the mounting surface should have a good machined finish. hread hread No.3

D-0-/80/90 Remote ontrol Relief Valves D / DG-0 Installation Drawings Lock Nut 4(.55) Hex. DIMENSIONS IN MILLIMERES (INHES) wo ollars 5 (.05) 6(.0) D-0- "A" hd. Rc /4 D-0-80 /4 BS.F (.97) D-0-90 /4 N Fully Extended 93 (7.60) 4.5 (5.57) Adjustment Handle IN. Dimensions of he anel Mounting Hole Max. 0(.39) 47 (.85) 6(.0) 45(.77) Dia. (.83) Dia. ort "A" hd. 74 (.9) ank ort "A" hd. Lock Nut 4(.94) Hex. DG-0-/90 : DGM-0-0/080/090 7 (.8) 9 (.75) 30 (.8) 5.5(.) Dia. hrough 9(.35) Dia. Spotface 4 laces 60 (.36) Lock Nut 4(.55) Hex. wo ollars (.97) 30 (.8) 7 (.06) 5 (.59) (.08) 0 (.39) 6.(.4) Dia. "A" hd. laces (From Rear) 7.5 (.30) 4 (.94) 5 (.05) 38 (.) 45(.77) Dia. 4 (.55) 3.5 (.53) ort ank ort (.97) 0 (.39) 5 (.05) 9 (.75) 38 (.) 65 (.56) 80 (3.5) Fully Extended 4.5 (5.6) 00 (3.94) Adjustment Handle IN. "B" hd. 0(.39) Deep 4 laces 47 (.85) 38 (.) 37 (.45) 6 (.0) 48.5 (.9) 7(.8) Dia. hrough (.43) ' bore 7(.8) Deep laces Mounting Surface (s Furnished) "A" hd. "B" hd. DGM-0-0 DGM-0-080 Rc /4 /4 BS.F M5 DGM-0-090 /4 N No. 0-4 UN No.4

Remote ontrol Relief Valves D / DG-0 Spare arts List D-0-/80/90 AUION When making replacement of seals, please do it carefully after reading through the relevant instructions in the Operator's Manual. 3 4 5 6 8 7 List of Seals Item 3 4 Name of arts arts Numbers SO-NA- SO-NB-.4 Qty. Note: When ordering the seals, please specify the seal kit number from the table below. 5 3 4 0 9 List of Seal Kits D-0 DG-0 Seal Kit Numbers KS-D-0- KS-DG-0- DG-0-/90 3 3 0 4 6 9 8 7 List of Seals Item Name of arts arts Numbers Qty. SO-NA-9 SO-NB-9 Note: When ordering the seals, please specify the seal kit number from the table below. 4 5 No.5

Direct ype Relief Valves D / DG-0 hreaded onnections / Specifications / Model Number Designation / others Specifications Max. Operat- res. Adj. Max. Flow Approx. Mass hreaded ing Range L/min kg (lbs.) onnections Mounting Ma (SI) Ma (SI) (U.S.GM) D type DG type 6 D-0- - DG-0- (30) Note) (4.).5 (3.3).5 (3.3) Note: Refer to the Model Num ber Designation. Model Number Designation F- Special Seals F: Special Seals for hosphate Ester ype Fluids (Om it if not required) D Series Number D: Direct ype Relief Valves y pe of Mounting : hreaded onnection G: Mounting -0 Valve 0 -B res. Adj. Range Ma (SI) B: -7 ( -00) : 3.5-4 (-0) H: 7- (00-30) - Design Number Design Standards None: Japanese Std. "JIS" 80: European Design Std. 90: N. American Design Std. None: Japanese Std. "JIS" and European Design Std. 90: N. American Design Std. Refer to the Minimum Adjustment haracteristics. Graphic Symbol Attachment Mounting bolts Valve Model Numbers Socket Head ap Screw Japanese Std. "JIS" and European Design Std. N. American Design Std. DG-0 M5 45 Lg. No.0-4UN -3/4 Lg. 4 Qty. Valve Model Numbers DG-0 Japanese Standard "JIS" European Design Standard N. American Design Standard hread hread hread Approx. Mass kg (lbs.) DGM-0-0 Rc /4 DGM-0-080 /4 BS.F DGM-0-090 /4 N 0.7 (.5) s are available. Specify the sub-plate model number from the table above. When sub-plates are not used, the mounting surface should have a good machined finish. he sub-plates are those for remote control relief valves. For dimensions, see page 4. No.6

Direct ype Relief Valves D / DG-0 haracteristics / Installation Drawings Min. Adjustment Min. Adjustment SI 75 5 00 75 5 0 Ma..0 0.8 0.6 0.4 0. 0 0 4 6 8 0 4 6 L/min 0 3 4 U.S. GM Flow Rate Nominal Override haracteristics SI 3000 0 000 0 000 0 0 Ma 7.5 D-0-H DG-0-H 4.0 0.5 D-0- DG-0-7.0 3.5 D-0-B DG-0-B 0 0 4 6 8 0 4 6 L/min 0 3 4 4.5 U.S. GM Flow Rate Lock Nut 4(.55) Hex. 5 (.05) 6(.0) (.97) D-0- - D-0- - 80 "A" hd. Rc /4 /4 BS.F /4 N ort "A" hd. Fully Extended 63 (6.4) (4.4) Adjustment Handle IN. Max. 0(.39) 47 (.85) 6(.0) 45(.77) Dia. (.83) Dia. 74 (.9) Lock Nut 4(.94) Hex. 5 (.05) 9(.75) 7 (.8) ank ort "A" hd. 5.5(.) Dia. hrough 9(.35) Dia. Spotface 4 laces 45(.77) Dia. Lock Nut 4(.55) Hex. ort (.97) 0 (.39) ank ort Fully Extended 63 (6.4) 00 (3.94) Adjustment Handle IN. 47 (.85) 38 (.) 6 (.0) 48.5 (.9).0 Hy draulic fluid: Viscosity : 35 mm /s (64 SSU) Specific Gravity : 0.8 D-0- -/80/90 Dimensions of he anel Mounting Hole DG-0- -/90 DIMENSIONS IN MILLIMERES (INHES) Mounting Surface (s Furnished) Note: For dimensions of the valve mounting surface, see the dimensional drawing (.4) of the sub-plate used together. No.7

Direct ype Relief Valves D / DG-0 Spare arts List D-0- -/80/90 DG-0- -/90 AUION When making replacement of seals, please do it carefully after reading through the relevant instructions in the Operator's Manual. 0 3 9 5 6 7 8 4 3 4 List of Seals Item Name of arts art Numbers Qty. Remarks 3 4 SO-NB-9 SO-NA- SO-NB-.4 Use only for DG-0 Note: When ordering the seals, please specify the seal kit number from the table below. List of Seal Kits D-0 DG-0 Seal Kit Numbers KS-D-0- KS-DG-0- No.8

ilot Operated Relief Valves B / BG- / 06 /0 hreaded onnections / Specifications / Model Number Designation Graphic Symbols Vent onnection Specifications hreaded onnection B-- -3 B-06- -3 B-0- -3 Mounting BG-- -3 BG-06- -3 BG-0- -3 Max. Operating Ma (SI) 5 (3630) res. Adj. Range Ma (SI) Note) -5 ( -3630) Max. Flow L/min (U.S.GM) 00 (6.4) 00 (5.8) 0 (06) Approx. Mass kg (lbs.) B ty pe BG ty pe 5.0 (.0) 5.0 (.0) 8.5 (8.7) 4.7 (0.4) 5.6 (.3) 8.7 (9.) Note: Refer to the Minimum adjustment characteristics on page 4. Yuken can offer flanged connection valves described below. For details, contact us. BF-0- -3 BF-6- -3 BF-4- -0 Max Operating res. Ma (SI) 5 (3630) (30) Max Flow L /m in (U.S.GM) 0 (06) 800 () 00 (37) Model Number Designation F- B Special Seals F: Special Seals for hosphate Ester ype Fluids (Om it if not required) Series Number B: ilot Operated Relief Valves y pe of Mounting : hreaded onnection G: Mounting - Valve 06 0 06 0 -V High Venting res. Feature V: For High Venting Feature (Om it if not required) Use high venting pressure ty pe to reduce the response time from unload to onload. -3 Design Number 3 3 3 3 3 3 Design Standards None: Japanese Std. "JIS" 80: European Design Std. 90: N. American Design Std. None: Japanese Std. "JIS" and European Design Std. 90: N. American Design Std. No.9

ilot Operated Relief Valves B / BG- / 06 / 0 Attachment / / Instructions Attachment Mounting Bolts Valve Socket Head ap Screw Japanese Std. "JIS" and European Design Std. N. American Design Std. BG- BG-06 BG-0 M 70 Lg. ( pcs.), M 95 Lg. ( pcs.) M6 60 Lg. ( pcs.), M6 80 Lg. ( pcs.) M0 70 Lg. ( pcs.), M0 90 Lg. ( pcs.) /-3UN -3/4 Lg. ( pcs.), /-3UN 3-3/4 Lg. ( pcs.) 5/8-UN -/4 Lg. ( pcs.), 5/8-UN 3-/4 Lg. ( pcs.) 3/4-0UN -3/4 Lg. ( pcs.), 3/4-0UN 3-/ Lg. ( pcs.) Valve Model Numbers Japanese Standard "JIS" European Design Standard N. American Design Standard hread hread hread Approx. Mass kg (lbs.) BG- BGM--0 BGM-X-0 Rc 3/8 Rc / BGM--3080 BGM-X-3080 3/8 BS.F / BS.F BGM--090 BGM-X-090 3/8 N / N.4 (5.3) 3. (6.8) BG-06 BGM-06-0 BGM-06X-0 Rc 3/4 Rc BGM-06-3080 BGM-06X-3080 3/4 BS.F BS.F BGM-06-090 BGM-06X-090 3/4 N N 4.7 (0.4) 5.7 (.6) BG-0 BGM-0-0 BGM-0X-0 Rc -/4 Rc -/ BGM-0-3080 BGM-0X-3080 -/4 BS.F -/ BS.F BGM-0-090 BGM-0X-090 -/4 N -/ N 8.4 (8.5) 0.3(.7) s are available. Specify the sub-plate model number from the table above. When sub-plates are not used, the mounting surface should have a good ma-chined finish. Instructions If a remote control relief valve is used in the vent circuit, see page 3. In addition, if the internal volume of the vent line is too large, chattering is likely to occur. hus, as far as possible reduce the inside Dia. and the length of the pipe. is limited by collars fitted. If a working pressure cannot be attained, remove some collars. One collar is equivalent to 0 Ma (4 SI). With a small flow, the setting pressure may be unstable. Use models numbered and 06 with a flow rate above 8 L/min (. U.S. GM) and model 0 with 5 L/min (4.0 U.S. GM). here are two threaded connection pressure ports. hey can be connected each other in-line; one as inlet and the other as an outlet or the valve can be used by plugging one of the pressure ports. No.0

ilot Operated Relief Valves hreaded onnections:b- / 06 / 0 Installation Drawings B-- -3/380/390 B-06- -3/380/390 B-0- -3/380/390 Lock Nut 4(.55) Hex. DIMENSIONS IN MILLIMERES (INHES) wo ollars "A" SQ. 4 positions of pressure adjustment handle are available by rotating cover assembly as shown. Vent ort "" hd. 380 Design Only 5 (.0) B Fully Extended Adjustment Handle IN. D F 45(.77) Dia. L J H K ort "S " hd. laces ank ort "S " hd. E Gauge onnection "U" hd. Q N A Dimensions mm (Inches) B D E F H J K L N Q B-- -3/380/390 B-06- -3/380/390 B-0- -3/380/390 75 (.95) 85 (3.35) (.57) (.97) 05 (4.3) 0 (3.98) 5 (.05) 80 (3.5) 78 (3.07) 96 (3.78).5 (5.93) 83 (7.0) 68.5 (.70) 89 (3.) 6 (.44) 74 (.9) 36 (.4) 49 (.93) 5 (.05) 80 (3.5) 90 (3.54) 0 (4.7) 45 (.77) 60 (.36) B-- B-- -3 B-- -380 B-06- -390 B-06- -3 B-06- -380 B-0- -390 B-0- -3 B-0- -380-390 hread "S" hd. "" hd. "U" hd. Rc 3/8 Rc 3/8 Rc /4 3/8 BS.F 3/8 N Rc 3/4 3/4 BS.F 3/4 N Rc -/4 -/4 BS.F -/4 N 3/8 BS.F 3/8 N Rc 3/8 3/8 BS.F 3/8 N Rc 3/8 3/8 BS.F 3/8 N /4 BS.r /4 N Rc /4 /4 BS.r /4 N Rc /4 /4 BS.r /4 N No.

ilot Operated Relief Valves Mounting:BG- / 06 / 0 Installation Drawings BG-- -3/390 BG-06- -3/390 BG-0- -3/390 MENSIONS IN MILLIMERES (INHES) Mounting Surface (s Furnished) Lock Nut 4(.55) Hex. wo ollars "A" SQ. 3 positions of pressure adjustment handle are available by rotating cover assembly as shown. B Fully Extended Adjustment Handle IN. Vent ort Locating in 6(.4) Dia. 45(.77) Dia. Gauge onnection "X " hd. Q 6 (.4) In case of BG-, no spotface are made at those two holes. N H U D V E F ort ank ort L K J "S " Dia. hrough "" Dia. Spotface 4 laces BG-- -3/390 BG-06- -3/390 BG-0- -3/390 75 (.95) 75 (.95) 85 (3.35) (.57) (.57) 45 (.77) 05 (4.3) 05 (4.3) 0 (3.98) 57 (.4) (.57) 47 (.85) 78 (3.07) 60 (.36) 67 (.64) 78 (3.07) 78 (3.07) 84 (3.3) 37 (5.39) 6 (6.34) 95 (7.68) Dimensions mm (Inches) A B D E F H J K L N Q S U V 4. (.56) 7 (.67) 0.7 (.8) 4 (.6) 5 (.05) 6 (.44) 8 (3.3) 04 (4.09) 4 (4.88) 7 (4.6) 4 (5.55) 75 (6.89) 77 (3.) 83.5 (3.9) 0 (4.33) (.87) 4.5 (.8) 6 (.4) 3.5 (.53) 7.5 (.69).5 (.85) (.83) 6 (.0) 3 (.6) 55 (.7) 38 (.) 45 (.77) 58 (.8) 65 (.56) BG-- -3 BG-- -390 BG-06- -3 BG-06- -390 BG-0- -3 BG-0- -390 hread "X" hd Rc /4 = /4 BS.r /4 N Rc /4 = /4 BS.r /4 N Rc /4 = /4 BS.r /4 N Mounting Surface ISO 664-AR-06--A ISO 664-AS-08--A ISO 664-A-0--A No.

for ilot Operated Relief Valves Installation Drawings BGM-,X-0 / 3080 / 090 BGM-06,06X-0 / 3080 / 090 BGM-0,0X-0 / 3080 / 090 "d" Dia. hrough "e" Dia. Spotface 4 laces "h" 4 laces J A B D F E "t" hd. 6.(.4) Dia. DIMENSIONS IN MILLIMERES (INHES) Z a H K X U S Q L Y V N 7(.8) Dia. 0(.39) Deep "n" hd. laces "b" Dia. laces f BGM- BGM-X BGM-06 BGM-06X BGM-0 BGM-0X BGM- BGM-X BGM-06 BGM-06X BGM-0 BGM-0X Dimensions mm (Inches) A B D E F H J K L N Q S 86 60 3 53.8 3. 6.9 49 3 3 86 (3.39) 3 6 (.0) 97 53.8 (3.39) (.36) (.5) (.) (.) (.06) (5.87) (.5) (4.84) 95 (.6) (3.8) (.) (3.74) (.83) 08 (4.5) 6 (4.96) 78 (3.07) 94 (3.70) 5 (.59) 6 (.63) 70 (.76) 8.6 (3.5) 4 (.6) 5.7 (.) 35 (.38) 4.3 (.63) 80 (7.09) 7 (8.94) Dimensions mm (Inches) 5 (.59) 6 (.63) (5.9) 95 (7.68) 06.5 (4.9) 9 (4.69) 38. (5.44) 58 (6.) U V X Y Z a b d e f 9 (.75) 37 (.46) 4 (.65) 47.4 (.87) 55.5 (.9) 76. (3.00) 0 (0) 3.8 (.94) 3.8 (.5) (.87) 33.4 (.3) 44.5 (.75) (.87) (.43).7 (.) 3 (.6) (.57) (.57) (.97) (.97) 63 (.48) 0 (.79) 5 (.98) 3 (.6) 4.5 (.57) 3 (.9) 8 (.0) (.43) 3.5 (.53) 7.5 (.69) 7.5 (.69) (.83) 6 (.0) 5 (.0) 6 (.44) 9 (.75) 4 (.94) 3 (.) 7. (.07) 8 (.7) 30. (.9) 7 (.67) (4.76) 54 (6.06) 66.7 (.63) 88.9 (3.) Model Numbers BGM- BGM-X BGM-06 BGM-06X BGM-0 BGM-0X Japanese Standard "JIS" Design "0" European Design Standard Design "3080" N. American Design Standard Design "090" "h" "n" hd. "t" hd. "h" "n" hd. "t" hd. "h" "n" hd. "t" hd. Rc 3/8 Rc / M hd. 0(.79) Deep 3/8 BS.F / BS.F /-3UN hd. (.87) Deep 3/8 N / N Rc 3/4 3/4 BS. F 3/4 N Rc /4 M6 hd. /4 BS.F 5/8-UN hd. Rc 5(.98) Deep BS.F 7(.06) Deep N /4 N Rc-/4 Rc -/ M0 hd. 8(.0) Deep -/4 BS.F -/ BS.F 3/4-0UN hd. 8(.0) Deep -/4 N -/ N M hd. 0(.79) Deep M6 hd. 5(.98) Deep M0 hd. 8(.0) Deep No.3

ilot Operated Relief Valves B / BG- / 06 / 0 erformance haracteristics Nominal Override haracteristics B-, BG- SI 3600 3300 300 000 5 SI 3600 3300 300 000 00 Ma 5 4 3 6 5 4.6.3.0 B-0, BG-0 Ma 5 4 3 6 5 4.0.6. 0 5 75 00 L/min 0 5 0 5 0 5 U.S. GM Flow Rate 0 00 00 300 0 L/min Hy draulic fluid:viscosity : 35 mm /s (64 SSU) Specific Gravity : 0.8 B-06, BG-06 SI 3600 3300 300 000 75 00 Ma 5 4 3 6 5 4.9.6.3 0 00 00 L/min 0 0 0 30 U.S. GM Flow Rate 0 5 75 00 U.S. GM Flow Rate Min. Adj. & Vent vs. Flow SI Ma 00 0.7 0.6 80 0.5 60 0.4 0.3 0. 0 0. 0 0 B-, BG- High Venting ype Vent Min. Adjustment Low Venting ype 0 5 75 00 L/min 0 5 0 5 0 5 U.S. GM Flow Rate Hy draulic fluid:viscosity : 35 mm /s (64 SSU) Specific Gravity : 0.8 B-06, BG-06 SI Ma 00.4..0 0.8 00 0.6 0.4 0. 0 0 High Venting ype Vent Min. Adjustment Low Venting ype 0 00 00 L/min 0 0 0 30 U.S. GM Flow Rate B-0, BG-0 SI Ma.6 5 00 00 0.4..0 0.8 0.6 0.4 0. 0 High Venting ype Vent Min. Adjustment Low Venting ype 0 00 00 300 0 L/min 0 5 75 00 U.S. GM Flow Rate No.4

ilot Operated Relief Valves B / BG- / 06 / 0 Spare arts List B-- -3/380/390 B-06- -3/380/390 B-0- -3/380/390 A 8 6 7 8 6 9 0 3 AUION When making replacement of seals, please do it carefully after reading through the relevant instructions in the Operator's Manual. 7 4 5 3 4 0 5 9 Item 6 7 4 List of Seals Name of arts Bonded Seal art Numbers B- B-06 B-0 SO-NA-9 SO-NB-3 SG-FB-3/8 SO-NA-9 SO-NB-3 SG-FB-3/8 SO-NA-9 SO-NB-4 SG-FB-3/8 Qty. Note: When ordering the seals, please specify the seal kit number from the table below. BG-- -3/390 BG-06- -3/390 BG-0- -3/390 4 3 Section "A" for Design 380 List of Seal Kits B- B-06 B-0 Seal Kit Numbers KS-B--3 KS-B-0-3 Note: No bonded seals are included in the seal kits. 6 6 7 8 7 9 0 3 0 8 4 9 5 3 4 4 5 3 5 List of Seals Item Name of arts 7 8 9 0 art Numbers Qty. BG- BG-06 BG-0 SO-NA-9 SO-NA-9 SO-NB-9 SO-NB- SO-NB-8 SO-NB-8 SO-NB-3 SO-NB-3 SO-NA-9 SO-NB-9 SO-NB-3 SO-NB-4 Note: When ordering the seals, please specify the seal kit number from the table below. List of Seal Kits Seal Kit Numbers BG- KS-BG--3 BG-06 KS-BG-06-3 BG-0 KS-BG-0-3 No.5

Low Noise ype ilot Operated Relief Valves S-BG- / 06 / 0 Specifications / Model Number Designation / Sub- Graphic Symbols Vent onnection Specifications Max. Operating Ma (SI) res. Adj. Range Ma (SI) Max. Flow L/min (U.S.GM) S-BG-- - - S-BG-06- - - 5 (3630) Note) -5 00 (6.4) 00 (5.8) S-BG-0- - ( -3630) 0 (06) Note: See minimum adjustment pressure characteristics on page 8. Approx. Mass kg (lbs.) 4. (9.0) 5.0 (.0) 0.5 (3.) Model Number Designation F- S- B Special Seals Low Noise ype Series Number G y pe of Mounting - Valve -V -L High Venting res. Feature Direction of Handle - Design Number Design Std. F: Special Seals for hosphate Ester y pe Fluids (Om it if not required) S: Low Noise ype B: ilot Operated Relief Valves G: Mounting 06 0 V: For High Venting Feature (Om it if not required) Viewed from pressure gauge connection L: Left (Normal) R: Right Refer to. Use the high venting pressure ty pe where it is necessary to reduce the response time from unloading to onloading.. Design Standards: None... Japanese Standard "JIS" and European Design Standard 90... N. American Design Standard Valve Model Numbers S-BG- S-BG-06 S-BG-0 Japanese Standard "JIS" European Design Standard N. American Design Standard BGM--0 BGM-X-0 BGM-06-0 BGM-06X-0 BGM-0-0 BGM-0X-0 hread Rc 3/8 Rc / Rc 3/4 Rc Rc -/4 Rc -/ BGM--3080 BGM-X-3080 BGM-06-3080 BGM-06X-3080 BGM-0-3080 BGM-0X-3080 hread 3/8 BS.F / BS.F 3/4 BS.F BS.F -/4 BS.F -/ BS.F BGM--090 BGM-X-090 BGM-06-090 BGM-06X-090 BGM-0-090 BGM-0X-090 hread 3/8 N / N 3/4 N N -/4 N -/ N Approx. Mass kg (lbs.).4 (5.3) 3. (6.8) 4.7 (0.4) 5.7 (.6) 8.4 (8.5) 0.3 (.7) s are available. Specify the sub-plate model number from the table above. When sub-plates are not used, the mounting surface should have a good machined finish. he sub-plates are those for pilot operated relief valves. For dimensions, see page 3. No.6

Attachment Mounting Bolts Valve Model Num bers S-BG- S-BG-06 S-BG-0 Low Noise ype ilot Operated Relief Valves Attachment / Instructions / Installation Drawings Japanese Std. "JIS" and European Design Std. M Lg. M6 Lg. M0 60 Lg. Socket Head ap Screw N. American Design Std. /-3 UN -/ Lg. 5/8- UN Lg. 3/4-0 UN -/4 Lg. Qty. 4 4 4 Instructions If a remote control relief valve is used in the vent circuit, see page 3. In addition, if the internal volume of the vent line is too large, chattering is likely to occur. hus, as far as possible reduce the inside Dia. and the length of the pipe. is limited by collars fitted. If a working pressure cannot be attained, remove some collars. One collar is equivalent to 0 Ma (4 SI). With a small flow, the setting pressure may be unstable. Use models numbered and 06 with a flow rate above 5 L/min (.3 U.S. GM) and model 0 with 8 L/min (. U.S. GM). S-BG-- -L-/90 S-BG-06- -L-/90 S-BG-0- -/90 DIMENSIONS IN MILLIMERES (INHES) Fully Extended J Fully Extended F E "K" Dia. hrough "N" Dia. Spotface 4 laces ort D B A Mounting surface S-BG-: ISO 664-AR-06--A S-BG-06: ISO 664-AS-08--A S-BG-0: ISO 664-A-0--A Opposite Handle osition S-BG- 06 - -R Z Fully Extended J Q Adjustment Handle IN. 45(.77) Dia. ank ort H wo ollars Lock Nut 4(.55) Dia. Vent ort Gauge onnection "Y " hd Note:For other dimensions, see the figures shown left. Note:For dimensions of the valve mounting surface, see the dimensional drawing (. 3) of the sub-plate used together. S "Y" hd. 6 (.4) Locating in 6(.4) Dia. Mounting Surface (s Furnished) V U X S-BG-- - - S-BG-- - -90 S-BG-06- - - S-BG-06- - -90 S-BG-0- - S-BG-0- -90 Rc /4 = /4 BS.r /4 N Rc /4 = /4 BS.r /4 N Rc /4 = /4 BS.r /4 N S-BG- S-BG-06 S-BG-0 A 76 (.99) 98 (3.86) 0 (4.7) Dimensions mm (Inches) B D E F H J K N Q S U V X Z 53.8 (.) 70 (.76) 8.6 (3.5). (.44) 4 (.55) 8.7 (.74) 6.9 (.06) 35 (.38) 4.3 (.63) 53.8 (.) 66.7 (.63) 88.9 (3.) 73.6 (.90) 58.8 (.3).6 (.99) 6.9 (.06) 33.7 (.33) 44.9 (.77) 63.5 (6.44) 63.5 (6.44) 80 (7.09) 3.5 (.53) 7.5 (.69).5 (.85) (.83) 6 (.0) 3 (.6) (.97) (.97) 65 (.56) 30 (5.) 30 (5.) 67 (6.57) (4.06) (4.06) 35 (5.3).5 (.85) 6 (.0) 33.5 (.3) 06 (4.7) (4.80) 55 (6.0) 6. (.) 9.3 (.76). (.83) 3 (.5) 3 (.5) 8 (.7) 36. (.4).3 (.84) No.7

Low Noise ype ilot Operated Relief Valves erformance haracteristics SI Ma 3600 5 4 3300 3 00 5 4 900 3.5.0 00 0.5 Nominal Override haracteristics Hy draulic fluid: Viscosity : 35 mm /s (64 SSU) S-BG- S-BG-06 Specific Gravity : 0.8 S-BG-0 0 0 60 80 0 5 0 5 0 5 U.S. GM Flow Rate SI 3600 3300 00 900 Ma 5 4 3 5 4 3.5.0 0.5 00 0 00 00 L/min L/min 0 0 0 30 U.S. GM Flow Rate SI 3600 30 300 600 0 00 300 Ma 5 4 3 5 4 3.0.5.0 0 00 00 300 0 L/min 0 5 75 00 Flow Rate U.S. GM Min. Adj. and Vent vs. Flow Hy draulic fluid: Vent Min. Adjustment Viscosity : 35 mm /s (64 SSU) Specific Gravity : 0.8 S-BG- S-BG-06 S-BG-0 SI 0 00 80 60 0 0 Ma 0.9 High Vent 0.8 ype 0.7 0.6 0.5 0.4 Low Vent 0.3 ype 0. 0. 0 0 0 60 80 00 L/min 0 5 0 5 0 Flow Rate 5 U.S. GM SI Ma 00.4 00 0..0 0.8 0.6 High Vent ype 0.4 0. Low Vent 0 ype 0 00 L/min 0 0 0 30 Flow Rate U.S. GM SI Ma 5.6 00.4..0 High Vent ype 0.8 00 0.6 0.4 0. 0 0 00 0 00 00 Low Vent ype 300 0 L/min 0 5 75 00 Flow Rate U.S. GM Noise Level M easuring condition Viscosity : 35 mm /s (64 SSU) Measuring position: At m (3.3 ft.) back from the valve front. Back pressure : 0. Ma (4.5 SI) S-BG- S-BG-06 S-BG-0 db(a) 80 Flow rate : L/min (3. U.S.GM) db(a) 80 Flow rate : L/min (39.6 U.S.GM) db(a) 80 Flow rate : 00 L/min (5.8 U.S.GM) Noise Level 70 60 Noise Level 70 60 Noise Level 70 60 0 4 8 6 0 Ma 0 4 8 6 0 Ma 0 4 8 6 0 Ma 0 000 000 3000 SI 0 000 000 3000 SI 0 000 000 3000 SI No.8

Low Noise ype ilot Operated Relief Valves Spare arts List S-BG-,06,0- -/90 3 4 0 0 6 3 4 5 7 8 9 9 5 30 3 4 5 8 3 7 6 9 8 6 7 AUION When making replacement of seals, please do it carefully after reading through the relevant instructions in the Operator's Manual. S-BG-0 3 9 List of Seals Item Name of arts art Numbers S-BG- S-BG-06 S-BG-0 5 SO-NB-9 SO-NB-9 SO-NB-9 6 SO-NA-9 SO-NA-9 SO-NA-9 7 SO-NB-9 SO-NB- SO-NB-9 8 SO-NB-8 SO-NB-8 SO-NB-3 9 SO-NB-A04 SO-NB-A04 SO-NB-A8 30 SO-NB-8 SO-NB-8 SO-NB-36 3 SO-NB-3 SO-NB-3 SO-NB-4 3 SO-NB-4 Note: When ordering the seals, please specify the seal kit number from the table below. Qty. List of Seal Kits Seal Kit Numbers S-BG- KS-S-BG-- S-BG-06 KS-S-BG-06- S-BG-0 KS-S-BG-0- Interchangeability in Installation betw een onventional ype and Low -noise ype he design of low-noise S-BG-, -06, and -0 is interchangeable for installation with design 3 of conventional BG-, -06 and -0. heir exterior shapes such as the position of the pressure adjustment handles are different. U V W onventional ype: BG- 3 06 0 Fully Extended 45 (5.7) 45(.77) Dia. Adjustment Handle Vent ort Gauge onnection ort ank ort, Design B A E "K" Dia. hrough "N" Dia. Spotface 4 laces ort Fully Extended J E Fully Extended F A B DIMENSIONS IN MILLIMERES (INHES) Low-noise type: S-BG- 06, Design 0 Vent ort Gauge onnection "K" Dia. hrough "N" Dia. Spotface 4 laces ank ort 45 (.77) Dia. W Adjustment Handle A B E K N U V A B E F K N J W BG- BG-06 BG-0 8 (3.3) 04 (4.09) 4 (4.88) 53.8 (.) 70 (.76) 8.6 (3.5) 53.8 (.) 66.7 (.63) 88.9 (3.) 3.5 (.53) 7.5 (.69).5 (.85) (.83) 6 (.0) 3 (.6) 7 (4.6) 4 (5.55) 75 (6.89) 55 (.6) 38 (.) 45 (.77) 78 (3.07) 58 (.8) 65 (.56) S-BG- S-BG-06 S-BG-0 76 (.99) 98 (3.86) 0 (4.7) 53.8 (.) 70 (.76) 8.6 (3.5) 53.8 (.) 66.7 (.63) 88.9 (3.) 73.6 (.90) 58.8 (.3).6 (.99) 3.5 (.53) 7.5 (.69).5 (.85) (.83) 6 (.0) 3 (.6) 63.5 (6.44) 63.5 (6.44) 80 (7.09) 0.5 (.8) 5 (.98) 3.5 (.8) No.9

Specifications Solenoid ontrolled Relief Valves BS / BSG- / 06 / 0 hreaded onnections / Specifications / Model Number Designation hreaded onnection Mounting BS-- - - - -47 BS-06- - - - -47 BSG-- - - - -47 BSG-06- - - - -47 Max. Operating Adj. Range Max. Flow L/min Ma (SI) Ma (SI) (U.S.GM) 5 (3630) 5 (3630) Note) -5 ( -3630) Note) -5 ( -3630) 00 (6.4) 00 (5.8) 0 (06) 00 (6.4) 00 (5.8) 0 (06) Double Sol. 7.4 (6.3) 7.4 (6.3). (4.5) 7. (5.7) 8.0 (7.6).3 (4.9) Approx. Mass kg (lbs.) Single Sol. 6.8 (5.0) 6.8 (5.0) 0.5 (3.) 6.5 (4.3) 7.4 (6.3) 0.7 (3.6) W ith Vent Restrictor 7.8 (7.) 7.8 (7.).5 (5.4) 7.5 (6.5) 8.4 (8.5).7 (5.8) Note: For relief valves, standard pilot operated relief valves are used. For minimum adjustment pressures and other characteristics, see page 4. Solenoid Ratings Electric Source A D (K Series) A D Rectified oil Frequency ype (Hz) A00 A0 A00 A D D4 D48 R00 R00 60 60 60 60 /60 Voltage (V) Source Rating 00 00 0 0 00 00 0 4 48 00 00 Serviceable Range 80~0 90~0 96 ~3 08 ~44 60~0 80~ 9 ~64 6 ~88 0.8 ~3..6 ~6.4 43. ~5.8 90 ~0 80~0 urrent & ower at Rated Voltage Inrush (A).4.4.35.0.78..07.8.0 0.89 Holding (A) 0.5 0.37 0.44 0.4 0.3 0.5 0.9 0. 0. 0.5.45.3 0.6 0.33 0.6 Inrush current in the above table shows rms values at maximum stroke. he coil type numbers in the shaded column are handled as optional extras. In case these coils are required to be chosen, please confirm the time of delivery with us before ordering. ower (W) 9 9 Yuken can offer flanged connection valves described below. onsult Yuken for the details. BSF-0- - - - -47 BSF-6- - - - -47 Max. Operating Ma (SI) 5 (3630) Max. Flow L/min (U.S.GM) 0 (06) 800 () Model Number Designation F- Special Seals A- W ith Vent Restrictor BS - -V -B3A -A00 -N -47 Series Number y pe of Mounting Valve High Venting res. Feature Vent ype oil y pe y pe of Electrical on. Design Number Design Standards F: Special Seals for hosphate Ester ype Fluids (Om it if not required) A: W ith Vent Restrictor (Option) BS: Solenoid ontrolled Relief Valves : hreaded onnection G: Mounting 06 0 V: For High Venting Feature (Om it if not required) B3A B3B BB B 3 33 3 A: A00, A0 A00, A D: D, D4 D48 A D: R00, R00 None: erminal Box y pe N: W ith lug-in onnector (DIN) N: W ith lug-in onnector (DIN) 47 None: Japanese Std. "JIS" 90: N. American Design Std. 80: European Design Std.. Models with vent restrictor are applicable only for the vent ty pe B3A and B3B. For details, see page.. 3. Use high-venting-pressure ty pes to reduce response time from unloading to onloading. For the details of the vent ty pes, see the following page. No.0

Solenoid ontrolled Relief Valves BS / BSG- / 06 / 0 Vent ypes / Attachment Vent ypes Vent y pe Graphic Sy mbols Solenoid Operated Directional Valve Model Number SOL "a" Operation SOL "b" Vent onnecting B3A "A" b DSG-0-B3A OFF onnected to port "A". ON onnected to tank (no-load) "B" b OFF onnected to tank (no-load) B3B DSG-0-B3B ON onnected to port "B". "B" b OFF losed state (relief valve setting pressure) BB DSG-0-BB ON onnected to port "B". "A" "B" b OFF onnected to port "A". B DSG-0-B ON onnected to port "B". a "A" "B" b OFF OFF losed state (relief valve setting pressure) 3 DSG-0-3 ON OFF onnected to port "A". OFF ON onnected to port "B". a "A" "B" b OFF OFF onnected to tank (no-load) 33 DSG-0-33 ON OFF onnected to port "A". OFF ON onnected to port "B". Attachment Mounting Bolts Valve Model Socket Head ap Screw Numbers Japanese Std. "JIS" and European Design Std. N. American Design Std. BSG- BSG-06 BSG-0 M 70 Lg. ( pcs.), M 95 Lg. ( pcs.) M6 60 Lg. ( pcs.), M6 80 Lg. ( pcs.) M0 70 Lg. ( pcs.), M0 90 Lg. ( pcs.) /-3UN -3/4 Lg. ( pcs.), /-3UN 3-3/4 Lg. ( pcs.) 5/8-UN -/4 Lg. ( pcs.), 5/8-UN 3-/4 Lg. ( pcs.) 3/4-0UN -3/4 Lg. ( pcs.), 3/4-0UN 3-/ Lg. ( pcs.) No.

Solenoid ontrolled Relief Valves BS / BSG- / 06 / 0 / Option / Instructions Valve Model Numbers Japanese Standard "JIS" European Design Standard N. American Design Standard hread hread hread Approx. Mass kg (lbs.) BSG- BSG-06 BSG-0 BGM--0 BGM-X-0 BGM-06-0 BGM-06X-0 BGM-0-0 BGM-0X-0 Rc 3/8 Rc / Rc 3/4 Rc Rc -/4 Rc -/ BGM--3080 BGM-X-3080 BGM-06-3080 BGM-06X-3080 BGM-0-3080 BGM-0X-3080 3/8 BS.F / BS.F 3/4 BS.F BS.F -/4 BS.F -/ BS.F BGM--090 BGM-X-090 BGM-06-090 BGM-06X-090 BGM-0-090 BGM-0X-090 3/8 N / N 3/4 N N -/4 N -/ N.4 (5.3) 3. (6.8) 4.7 (0.4) 5.7 (.6) 8.4 (8.5) 0.3(.7) s are available. Specify the sub-plate model number from the table above. When sub-plates are not used, the mounting surface should have a good machined finish. he sub-plates are those for pilot operated relief valves. For dimensions, see page 3. Option Models with vent restrictor he type with a vent restrictor has a vent restrictor in vent types B3A and B3B added between a relief valve and a solenoid operated directional valve. If prevents shock to the main circuit by gradually lowering the venting pressure in the shift from the set pressure to unloading. Unloading pressure are the same as without a vent restrictor. A-BS - -B3A A-BS - -B3B b b Instructions If a remote control relief valve is used in the vent circuit, see page 3. In addition, if the internal volume of the vent line is too large, chattering is likely to occur. hus, as far as possible reduce the inside Dia. and the length of the pipe. is limited by collars fitted. If a working pressure cannot be attained, remove some collars. One collar is equivalent to 0 Ma (4 SI). With a small flow, the setting pressure may be unstable. Use models numbered and 06 with a flow rate above 8 L/min (. U.S. GM) and model 0 with 5 L/min (4.0 U.S. GM). here are two threaded connection pressure ports. hey can be connected each other in-line; one as inlet and the other as an outlet or the valve can be used by plugging one of the pressure ports. Interchangeability in Installation betw een Old and New Design. Design 47 valve is one on which DSG-0,design 60 is mounted as a pilot valve. It is interchangeable with old design (design 46) with respect to specifications, exterior shape and mounting dimensions. No.

Solenoid ontrolled Relief Valves hreaded onnections:bs- / 06 / 0 Installation Drawings BS-- -47/4790 BS-06- -47/4790 BS-0- -47/4790 erminal Box ype Solenoid Indicator Light DIMENSIONS IN MILLIMERES (INHES) "" SQ. Vent ort "k" hd. ank ort "X " hd. D 48 (.89) "E " Sq. F Fully Extended H osition can be shifted by 90 Steps. Lock Nut 4(.55) Hex. 45(.77) Dia. wo ollars Adjustment Handle IN. Remote ontrol ort "B" "W " hd. ort "X " hd. laces Gauge onnection "h" hd. 0.5 (.0) D/R :0(8.7) A :9.4(7.54) SOLa 45 D/R :05(4.3) (.77) A :95.7(3.77) 45(.77) K L SOLb V Space Needed to Remove Solenoid-Each End D/R :55(.7) A :45.5(.79) U S Electrical onduit onnection "r" hd. laces Q N Remote ontrol ort "A" "W " hd. Manual Actuator Both Ends 6(.4) Dia. D E Dimensions mm (Inches) F H K L N Q S U V BS-- -47/4790 BS-06- -47/4790 75 (.95) (.57) 5 (.05) 78 (3.07) 45 (5.7) 45 (.77) 90 (3.54).8 (9.48) 68.5 (.70) 54 (6.06) 36 (.4) 07 (4.) 69 (.7) 6 (.44) BS-0- -47/4790 85 (3.35) (.97) 80 (3.5) 96 (3.78) 5 (5.94) 60 (.36) 0 (4.7) 73.3 (0.76) 89 (3.) 66 (6.54) 49 (.93) 9 (4.69) 8 (3.9) 74 (.9) BS- BS-06 BS-0 Japanese Standard "JIS" Design 47 N. American Design Standard Design 4790 "W " hd. "X" hd. "h" hd. "k" hd. "r" hd. "W " hd. "X" hd. "h" hd. "k" hd. "r" hd. Rc 3/8 3/8 N Rc /8 Rc 3/4 Rc -/4 Rc /4 Rc 3/8 G / /8 /4 3/8 / 3/4 N N N N N -/4 N No.3

Models with lug-in onnector BS- 06 - - - -N-47/4780/4790 0 ort "X " hd. laces SOL a Remote ontrol ort "B" "W " hd. Vent ort "m" hd. (Rear Side) D/R A 48.5 (.9) :0(8.7) :9.4(7.54) 48.5 (.9) ank ort "X " hd. h Solenoid ontrolled Relief Valves hreaded onnections:bs- / 06 / 0 Installation Drawings Design 4780 Only able Departure able Applicable: Outside Dia. 8-0mm(.3-.39 in.) onductor Area Not Exceeding.5mm (.00 SQ. in.) QQ NN Remote ontrol ort "A" "W " hd Gauge onnection "k" hd DIMENSIONS IN MILLIMERES (INHES) BS-- -A BS-06- -N -A -N BS-0- -A -N BS-- -D -N BS-06- -D -N BS-0- -D -N BS-- -R -N BS-06- -R -N BS-0- -R -N 68.5 (.70) 89 (3.) 68.5 (.70) 89 (3.) 68.5 (.70) 89 (3.) Dimensions mm(inches) NN QQ h 07 (4.) 9 (4.69) 07 (4.) 9 (4.69) 07 (4.) 9 (4.69).5 (9.47) 73 (0.75) 5.5 (9.90) 84 (.8) 54.5 (0.0) 87 (.30) 60 (6.30) 7 (6.77) 7 (6.73) 83 (7.0) 64. (6.46) 76. (6.94) 39 (.54) 39 (.54) 53 (.09) "W " hd. "X" hd. "k" hd. "m" hd. BS-- - - -N-4780 BS-06- - - -N-4780 BS-0- - - -N-4780 /8 BS.F 3/8 BS.F 3/4 BS.F -/4 BS.F /4 BS.r 3/8 BS.r See the installation drawing of terminal box ty pe on page 3 for design 47 and 4790 port screws and other dimensions. Options - Models w ith Vent Restrictor erminal Box ype A-BS- 06 - - B3A B3B - -47/4790 0 D/R :05(4.3) A :95.7(3.77) lug-in onnector ype A-BS- 06 - - B3A B3B - -N-47/4780/4790 0 D/R :05(4.3) A :95.7(3.77) NN QQ N Q Item A-BS- A-BS-06 A-BS-0 68.5 (.70) 89 (3.) 37 (5.39) 49 (5.87) lug-in onnector y pe erminal Box y pe A Solenoid D Solenoid R (A D) Solenoid N Q NN QQ NN QQ NN QQ 70.8 (0.66) 3.3 (.94) 84 (7.4) 96 (7.7) 70.5 (0.65) 3 (.93) 90 (7.48) 0 (7.95) 8.5 (.08) 34 (.36) 0 (7.9) 3 (8.39) 84.5 (.0) 37 (.48) 94. (7.65) 06. (8.) For other dimensions, see the models without vent restrictor ty pe on page 3 and 4. No.4

BSG-- -47/4790 BSG-06- -47/4790 BSG-0- -47/4790 erminal Box ype Solenoid ontrolled Relief Valves Mounting:BSG- / 06 / 0 Installation Drawings Solenoid Indicator Light Mounting surface BSG-: ISO 664-AR-06--A BSG-06: ISO 664-AS-08--A BSG-0: ISO 664-A-0--A DIMENSIONS IN MILLIMERES (INHES) "" SQ. Mounting Surface (s Furnished) Locating in 6(.4) Dia. 6 (.4) D 48 (.89) wo ollars 45(.77) Dia. Lock Nut 4(.55) Hex. Adjustment Handle IN. 0.5 (.0) SOLa Remote ontrol ort "B" "d" hd. Vent ort Gauge onnection "e" hd. D/R :0(8.7) A :9.4(7.54) 45 (.77) D/R :05(4.3) A :95.7(3.77) 45 (.77) SOLb X V Space Needed to Remove Solenoid-Each End U D/R :55(.7) A :45.5(.79) Electrical conduit connection "f" hd. laces S Q Manual Actuator Both Ends 6(.4) Dia. Remote control port "A" "d" hd. In case of BSG-, no spotface are made at those two holes. a E b F H Fully Extended J ort ank ort N L K "Y " Dia. hrough "Z" Dia. Spotface 4 laces Model Numbers BSG- BSG-06 BSG-0 D E F H J K L N Q S U V X Y Z a b 75 (.95) 75 (.95) 85 (3.35) 57 78 78 45 (.57) (.4) (3.07) (3.07) (5.7) 60 78 45 (.57) (.57) (.36) (3.07) (5.7) 45 47 67 84 46 (.77) (.85) (.64) (3.3) (5.75) 4. (.56) 7 (.67) 0.7 (.8) 4 (.6) 5 (.05) 6 (.44) Dimensions mm (Inches) 8 (3.3) 04 (4.09) 4 (4.88) 7.3 (8.95) 5.3 (9.89) 77 (3.) 83.5 (3.9) 85.3 0 (.3)(4.33) 3 (5.0) 49.5 (5.89) 57 (6.8) (.87) 4.5 (.8) 6 (.4) 85 47 (3.35) (.85) 0.5 64.5 (4.04) (.54) 0 7 (4.33) (.83) (.57) 57.5 (.6) 65 (.56) 3.5 (.53) 7.5 (.69).5 (.85) (.83) 55 (.7) 6 38 (.0) (.) 3 45 (.6) (.77) 58 (.8) 65 (.56) BSG- BSG-06 BSG-0 Japanese Standard "JIS" Design 47 N. American Design Standard Design 4790 "d" hd. "e" hd. "f" hd. "d" hd. "e" hd. "f" hd. Rc /8 Rc /4 G / /8 N /4 N / N Note: For dimensions of the valve mounting surface, see the installation drawing (.3) of the sub-plate used together. No.5

Solenoid ontrolled Relief Valves Mounting:BSG- / 06 / 0 Installation Drawings Models with lug-in onnector BSG- 06 - - - -N-47/4780/4790 0 Remote ontrol ort "B" "d" hd. Vent ort SOLa D/R :0(8.7) A :9.4(7.54) 48.5 (.9) 48.5 (.9) h SOLb Design 4780 Only able Departure able Applicable: Outside Dia. 8-0mm(.3-.39 in.) onductor Area Not Exceeding.5mm (.00 SQ. in.) U SS Q BSG-- -A -N BSG-06- -A -N BSG-0- -A -N BSG-- -D -N BSG-06- -D -N BSG-0- -D -N BSG-- -R -N BSG-06- -R -N BSG-0- -R -N 77 (3.) 83.5 (3.9) 0 (4.33) 77 (3.) 83.5 (3.9) 0 (4.33) 77 (3.) 83.5 (3.9) 0 (4.33) Dimensions mm(inches) Q U SS h 85 (3.35) 0.5 (4.04) 0 (4.33) 85 (3.35) 0.5 (4.04) 0 (4.33) 85 (3.35) 0.5 (4.04) 0 (4.33) 7 (8.94) 5 (9.88) 85 (.) 38 (9.37) 6 (0.3) 96 (.65) 4 (9.49) 65 (0.43) 99 (.77) 38 (5.43) 55.5 (6.) 63 (6.4) 49 (5.87) 66.5 (6.56) 74 (6.85) 4. (5.60) 59.7 (6.9) 67. (6.58) 39 (.54) 39 (.54) 53 (.09) ort ank ort DIMENSIONS IN MILLIMERES (INHES) D/R :05(4.3) A :95.7(3.77) Remote ontrol ort "A" "d" hd. Gauge onnection "e" hd Options - Models w ith Vent Restrictor erminal Box ype A-BSG- 06 - - B3A B3B - -47/4790 0 BSG-- - - -N-4780 BSG-06- - - -N-4780 BSG-0- - - -N-4780 "d" hd. /8 BS.F "e" hd. /4 BS.r See the installation drawing of terminal box ty pe on page 5 for design 47 and 4790 port screws and other dimensions. lug-in onnector ype A-BSG-06 - - B3A - -N-47/4780/4790 B3B 0 D/R :05(4.3) A :95.7(3.77) Q Q U U S SS Item A-BSG- A-BSG-06 A-BSG-0 Q 77 (3.) 83.5 (3.9) 0 (4.33) U 5 (4.53) 3.5 (5.) (5.5) lug-in onnector y pe erminal Box y pe A Solenoid D Solenoid R (A D) Solenoid S SS SS SS 57.3 (0.3) 8.3 (.07) 35.3 (.4) 6 (6.38) 79.5 (7.07) 87 (7.36) 57 (0.) 8 (.06) 35 (.) 68 (6.6) 85.5 (7.30) 93 (7.60) 68 (0.55) 9 (.) 36 (.83) 79 (7.05) 96.5 (7.74) 04 (8.) 7 (0.67) 95 (.6) 39 (.95) 7. (6.78) 89.7 (7.47) 97. (7.76) For other dimensions, see the models without vent restrictor ty pe on page 5 and 6.

Solenoid ontrolled Relief Valves BS / BSG- / 06 / 0 Lead Wire onnection Details of Receptacle y pe of Electrical onduit onnection Double Solenoid y pe Single Solenoid y pe ower Supply (For SOL.a) Ground 3 ower Supply (For SOL.b) 3 ower Supply 3 erminal Box y pe Indicator Light SOL. a SOL. b SOL. b ommon late Indicator Light Indicator Light ommon 3 Ground Ground lug-in onnector ype -ower Supply 3 3 Ground -ower Supply 3 3. here are two grounding terminals. You can use either one.. If y ou do not need the common plate, remove it. 3. With D solenoids, polarity is no question. DANGER Do not perform wiring while the power is on. Doing so may result in electric shock, burns or death. Make the wiring properly. Improper wiring will cause an irregular movement of the machine, resulting in a grave accident. Electrical ircuit y pe of Electrical onduit onnection Electric Source A D A D Rectified erminal Box y pe ower Supply Indicator Light ower Supply Indicator Light ower Supply Indicator Light Voltage-Surge Suppressor SOL. SOL. SOL. ommon Ground ommon Ground Voltage-Surge Suppressor ommon Ground Rectifier ircuit lug-in onnector ype -ower Supply -ower Supply Ground Indicator Light (Integrated in "N" model only) SOL. -ower Supply -ower Supply Ground Indicator Light (Integrated in "N" model only) SOL. Voltage-Surge Suppressor (ircuit composed in coil) -ower Supply -ower Supply Ground Voltage-Surge Suppressor Rectifier ircuit SOL. No.7

Solenoid ontrolled Relief Valves BS-,06,0 Spare arts List hreaded onnections erminal Box ype BS- 06 - - - -47/4790 0 AUION When making replacement of seals or solenoid assemblies, please do it carefully after reading through the relevant instructions in the Operator's Manual. 6 3 7 8 0 3 5 4 SOL a 7 9 8 4 9 6 5 3 0 4 Models with lug-in onnector BS- 06 - - - -N-47/4780/4790 0 3 Option Models with Vent Restrictor 47/4790 A-BS- 06 - - - - 0 N-47/4780/4790 4 37 9 8 30 35 SOL a 34 35 Design 4780 Only 8 36 38 List of Seals Item 35 38 Name of arts Bonded Seal art Numbers BS- BS-06 BS-0 SO-NA-9 SO-NB-3 SG-FB-/8 SO-NA-9 SO-NB-3 SG-FB-/8 SO-NB-8 SO-NB-4 SO-NA-9 SO-NB-4 SG-FB-/8 Qty. he s for Item 38, are used only for the models with the vent restrictor. Note: When ordering the seals, please specify the seal kit number from the table right. In addition to the above seals, seals for the pilot valves are included in the seal kit. For the detail of the pilot valve seals, see the catalogue No. ub.e- 0. List of Seal Kits BS- BS-06 BS-0 A-BS- A-BS-06 A-BS-0 Seal Kit Numbers KS-BS--46 KS-BS-0-46 KS-A-BS--46 KS-A-BS-0-46 Note: No bonded seals are included in the seal kits. ilot Valves See page 30 for the pilot valve model numbers to be used. No.8

Mounting erminal Box ype BSG- 06 - - - -47/4790 0 Solenoid ontrolled Relief Valves BSG- / 06 / 0 Spare arts List AUION When making replacement of seals or solenoid assemblies, please do it carefully after reading through the relevant instructions in the Operator's Manual. 6 6 8 0 3 5 4 7 9 6 9 5 4 3 0 4 5 3 SOL a Models with lug-in onnector BSG- 06 - - - -N-47/4780/4790 0 6 Option Models with Vent Restrictor 47/4790 A-BSG- 06 - - - - N-47/4780/4790 0 4 37 9 8 30 35 SOL a 3 3 Design 4780 Only 8 36 38 List of Seals Item 3 4 3 38 Name of arts Bonded Seal art Numbers BSG- BSG-06 BSG-0 SO-NA-9 SO-NA-9 SO-NA-9 SO-NB-9 SO-NB- SO-NB-9 SO-NB-8 SO-NB-8 SO-NB-3 SO-NB-3 SO-NB-3 SO-NB-4 SG-FB-/8 SG-FB-/8 SG-FB-/8 SO-NB-8 SO-NB-4 Qty. he s for item 38, are used only for the models with the vent restrictor. List of Seal Kits BSG- BSG-06 BSG-0 A-BSG- A-BSG-06 A-BSG-0 Seal Kit Numbers KS-BSG--46 KS-BSG-06-46 KS-BSG-0-46 KS-A-BSG--46 KS-A-BSG-06-46 KS-A-BSG-0-46 Note:No bonded seals are included in the seal kits. ilot Valves See page 30 for the pilot valve model numbers to be used. Note: When ordering the seals, please specify the seal kit number from the table right. In addition to the above seals, seals for the pilot valves are included in the seal kit. For the detail of the pilot valve seals, see the catalogue No. ub. E- 0. No.9

Solenoid ontrolled Relief Valves BS / BSG- / 06 / 0 Spare arts List List of ilot Valves y pe of Electrical onduit onnection Valve Model Num bers -BS/BSG-/06/0- -B3A- -47 -BS/BSG-/06/0- -B3B- -47 -BS/BSG-/06/0- -BB- -47 -BS/BSG-/06/0- -B- -47 -BS/BSG-/06/0- -3- -47 -BS/BSG-/06/0- -33- -47 -BS/BSG-/06/0- -B3A- -4790 -BS/BSG-/06/0- -B3B- -4790 -BS/BSG-/06/0- -BB- -4790 -BS/BSG-/06/0- -B- -4790 -BS/BSG-/06/0- -3- -4790 -BS/BSG-/06/0- -33- -4790 -BS/BSG-/06/0- -B3A- -N-47 -BS/BSG-/06/0- -B3B- -N-47 -BS/BSG-/06/0- -BB- -N-47 -BS/BSG-/06/0- -B- -N-47 -BS/BSG-/06/0- -3- -N-47 -BS/BSG-/06/0- -33- -N-47 -BS/BSG-/06/0- -B3A- -BS/BSG-/06/0- -B3B- -BS/BSG-/06/0- -BB- -BS/BSG-/06/0- -B- -N-4780 -BS/BSG-/06/0- -3- -N-4780 -BS/BSG-/06/0- -33- -N-4780 -BS/BSG-/06/0- -B3A- -BS/BSG-/06/0- -B3B- -BS/BSG-/06/0- -BB- -BS/BSG-/06/0- -B- -N-4790 -BS/BSG-/06/0- -3- -N-4790 -BS/BSG-/06/0- -33- -N-4790 ilot Valve DSG-0-B3A- -60 DSG-0-B3B- -60 DSG-0-BB- -60 DSG-0-B- -60 DSG-0-3- -60 DSG-0-33- -60 erminal Box y pe DSG-0-B3A- -6090 DSG-0-B3B- -6090 DSG-0-BB- -6090 DSG-0-B- -6090 DSG-0-3- -6090 DSG-0-33- -6090 DSG-0-B3A- -N-60 DSG-0-B3B- -N-60 DSG-0-BB- -N-60 DSG-0-B- -N-60 DSG-0-3- -N-60 DSG-0-33- -N-60 -N-4780 DSG-0-B3A- -N-60 -N-4780 DSG-0-B3B- -N-60 lug-in onnector y pe -N-4780 DSG-0-BB- -N-60 DSG-0-B- -N-60 DSG-0-3- -N-60 DSG-0-33- -N-60 -N-4790 DSG-0-B3A- -N-6090 -N-4790 DSG-0-B3B- -N-6090 -N-4790 DSG-0-BB- -N-6090 DSG-0-B- -N-6090 DSG-0-3- -N-6090 DSG-0-33- -N-6090 Note:. Fill a coil ty pe (a sy m bol representing current/voltage) in section m arked.. For the details of the pilot valves, see the atalogue No. ub. E-0. Rem arks Japanese Standard "JIS" N. American Design Std. Japanese Standard "JIS" European Design Std. N. American Design Std. No.30

Low Noise ype Solenoid ontrolled Relief Valves Specifications / Model Number Designation Specifications Mounting S-BSG-- - - - -5 S-BSG-06- - - - -5 S-BSG-0- - - - -5 Max. Operating Ma (SI) 5 (3630) Adj. Range Ma (SI) - 5 ( - 3630) Max. Flow L/min (U.S.GM) 00 (6.4) 00 (5.8) 0 (06) Double Sol. 6.3 (3.9) 7. (5.9).7 (8.0) Approx. Mass Single Sol. 5.7 (.6) 6.6 (4.6). (6.7) kg (lbs.) W ith Vent Restrictor 6.7 (4.8) 7.6 (6.8) 3. (8.9) For relief valves, low-noise ty pe pilot operated relief valves are used. For minimum adjustment pressures and other characteristics, see page 8. Solenoid Ratings Solenoid ratings are the same as for the conventional type. See Solenoid Ratings on page 0. Model Number Designation F- A- S- BS G Special Seals W ith Vent Restrictor Low Noise ype Series Number ype of Mtg. - Valve size -V High Venting res. Feature -B3A Vent ype -A00 oil ype -N y pe of Electrical onnections -L Direction of Handle 5 Design Number Design Standards F: Special Seals for hosphate Ester ype Fluids (Om it if not required) A: W ith Vent Restrictor (option) S: Low Noise ype BS: Solenoid ontrolled Relief Valves G: Sub -plate Mtg. 06 0 V: For High Venting Feature (Om it if not required) 3 B3A B3B BB B 3 33 A: A00 A0 A00 A D: D D4 D48 A D: R00 R00 4 None: erminal Box y pe N: W ith lug-in onnector (DIN) N: W ith lug-in onnector (DIN) Viewed from pressure gauge onnection L: Left (Normal) R: Right 5 None: Japanese Std. "JIS" 90: N. American Design Std. 80: European Design Std.. Models with vent restrictor are applicable only for the vent ty pe B3A and B3B. For details, see page 3.. Use high-venting-pressure ty pes to reduce response time from unloading to onloading. 3. he vent ty pes are the same as for the conventional ty pe solenoid controlled relief valves. For the details of the vent ty pes, see page. 4. he coil codes are the same as for the conventional ty pe solenoid controlled valves. See the solenoid ratings on page 0. No.3

Low Noise ype Solenoid ontrolled Relief Valves Mounting : S-BSG- / 06 / 0 Option / / Attachment / Instructions Option Models with vent restrictor he type with a vent restrictor has a vent restrictor in vent types B3A and B3B added between a relief valve and a solenoid operated directional valve. It prevents shock to the main circuit by gradually lowering the venting pressure in the shift from the setting pressure to unloading. Unloading pressures are the same as without a vent restrictor. A-S-BSG- -B3A b A-S-BSG- -B3B b Valve Model Numbers Japanese Standard "JIS" European Design Standard N. American Design Standard hread hread hread Approx. Mass kg (lbs.) S-BSG- BGM--0 BGM-X-0 Rc 3/8 Rc / BGM--3080 BGM-X-3080 3/8 BS.F / BS.F BGM--090 BGM-X-090 3/8 N / N.4 (5.3) 3. (6.8) S-BSG-06 BGM-06-0 BGM-06X-0 Rc 3/4 Rc BGM-06-3080 BGM-06X-3080 3/4 BS.F BS.F BGM-06-090 BGM-06X-090 3/4 N N 4.7 (0.4) 5.7 (.6) S-BSG-0 BGM-0-0 BGM-0X-0 Rc -/4 Rc -/ BGM-0-3080 BGM-0X-3080 -/4 BS.F -/ BS.F BGM-0-090 BGM-0X-090 -/4 N -/ N 8.4 (8.5) 0.3(.7) s are available. Specify the sub-plate model number from the table above. When sub-plates are not used, the mounting surface should have a good machined finish. he sub-plates are those for pilot operated relief valves. For dimensions, see page 3. Attachment Mounting Bolts Valve Model Socket Head ap Screw Numbers Japanese Std. "JIS" and European Design Std. N. American Design Std. Qty. S-BSG- M Lg. /-3 UN -/ Lg. 4 S-BSG-06 M6 Lg. 5/8- UN Lg. 4 S-BSG-0 M0 60 Lg. 3/4-0 UN -/4 Lg. 4 Instructions If a remote control relief valve is used in the vent circuit, see page 3. In addition, if the internal volume of the vent line is too large, chattering is likely to occur. hus, as far as possible reduce the inside Dia. and the length of the pipe. is limited by collars fitted. If a working pressure cannot be attained, remove some collars. One collar is equivalent to 0 Ma (4 SI). With a small flow, the setting pressure may be unstable. Use models numbered and 06 with a flow rate above 5 L/min (.3 U.S. GM) and model 0 with 8 L/min (. U.S. GM). No.3

erminal Box ype Opposite Handle osition S-BSG- - - - - -R 06 SOL a B j A Low Noise ype Solenoid ontrolled Relief Valves Installation Drawings S-BSG- - - - - -L-5/590 06 S-BSG-0- - - - -5/590 "N" Dia. hrough " " Dia. Spotface 4 laces Fully Extended J Fully Extended h H Mounting surface S-BSG-: ISO 664-AR-06--A S-BSG-06: ISO 664-AS-08--A S-BSG-0: ISO 664-A-0--A Solenoid Indicator Light ort E D F r m Note: For other dimensions, see the figures shown right Electrical onduit onnection Design Std. hd. 5 G / 590 / N laces 48 (.89) ank ort Space Needed to Remove Solenoid-Each End D/R :55(.7) A :45.5(.79) D/R :60(.36) A :.7(.00) L K D/R :0(8.7) A :9.4(7.54) 90 0.5 (3.54) (.0) Vent ort Gauge onnection "nn" hd. Q S Remote ontrol ort "A" "ff" hd. U V Manual Actuator Both Ends 6(.4) Dia. Remote ontrol ort "B" "ff" hd. Adjustment Handle IN. 45(.77) Dia. wo ollars Lock Nut 4(.55) Hex. SOL a A B f X Mounting Surface Locating in Y (s Furnished) e 6(.4) Dia. Z d Model Dimensions mm (Inches) Numbers D E F H J K N Q S U V X Y Z d e f h m r S-BSG- 76 53.8. 6.9 53.8 73.6 6.9 3.5 8.3 00 53 7.5 7. 36.6 06 6. 3 63.5 7.4 36. (.99)(.) (.44) (.06)(.)(.90)(.06) (.53) (.83) (8.59)(7.87)(6.0)(4.6)(4.06) (.85) (.67) (.44)(4.7)(.) (.5) (6.44)(5.0)(.4) S-BSG-06 98 70 4 35 66.7 58.8 33.7 7.5 6 8.3 00 53 7 6 3.9 5.4 9.3 3 63.5 4..3 (3.86)(.76) (.55) (.38)(.63)(.3)(.33) (.69) (.0)(8.59)(7.87)(6.0)(4.6)(4.06)(.0)(.6)(.0)(4.80) (.76) (.5) (6.44)(5.60) (.84) S-BSG-0 0 8.6 8.7 4.3 88.9 46. 44.9.5 3 53.3 35 88 49 35 34 43. 6.7 55. 8 80 (4.7)(3.5) (.74) (.63)(3.)(.8)(.77) (.85) (.6)(9.97)(9.5)(7.)(5.87)(5.3)(.34)(.70)(.47)(6.0) (.83) (.7) (7.09) 6 (.4) Item S-BSG- S-BSG-06 S-BSG-0 L 68.8 (.7) 54 (.3) 4.8 (.65) A Solenoid j 58.7 (6.5) 58.7 (6.5) For the port screws, see the lug-in onnector ty pe on page 34. L 78. (3.07) 63.3 (.49) 5. (.0) D/R Solenoid j 68 (6.6) 68 (6.6) Note: For dimensions of the valve mounting surface, see the installation drawing (.3) of the subplate used together. DIMENSIONS IN MILLIMERES (INHES) No.33