POWERCON CORPORATION

Similar documents
POWERCON CORPORATION

Specification Guide. for RMVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Advance design OEM L-Frames, cell kits, & enclosures Metal-clad switchgear components OEM catalog & pricing

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

Power/Vac Vacuum Replacement Breakers for GE Magne-Blast Type AM & AMH Breakers

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

www. ElectricalPartManuals. com lncoming-6900 through 69,000 volts Outgoing-2400 through 13,800 volts Ratings:

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

www. ElectricalPartManuals. com Section 13 Switchgear Low Voltage

Medium Voltage. ANSI C37.20 and NEMA SG-5

Medium Voltage Equipment 5-15 kv GM-SG and 38 kv GM38 Metal-Clad Switchgear General

GE Industrial Solutions. User/Installation Manual for 4.76kV -15kV SecoBloc

Medium Voltage Metal-Enclosed Switches

Specification Guide. for RMAX. Direct Replacement. AC Low Voltage. Power Circuit Breakers

Medium Voltage Metal-Enclosed Switches

ATLV MaxSG. Low Voltage Metal Enclosed Switchgear

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

Tradition. Technology. Innovation.

Design Build Deliver. Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak

MEDIUM VOLTAGE PRODUCTS

University of Houston Master Construction Specifications Insert Project Name

MEDIUM VOLTAGE AIR INSULATED ARC-RESISTANT LOAD BREAK AND DISCONNECT SWITCHES

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

Instruction Booklet for the Installation, Operation and Maintenance of Type 5-15 kv VCP-WG Vacuum Circuit Breaker 4000A MiniMod

VacClad-W type VCP-W 5 and 15 kv, 36-inch-wide switchgear components

Type SDV6 distribution circuit breaker. Top performance - proven reliability. Answers for energy.

Ampgard The name motor applications rely on

SWITCHGEAR DIVISION PRODUCT PROFILES

SIMOVAC and SIMOVAC-AR. Medium-voltage controllers 2.3 kv kv. usa.siemens.com/simovac

Custom Medium and LV Switchgear 5-38kV Switchgear Power Systems

Metal Clad VCBs ~ Mk1

MASTERCLAD Metal-Clad Indoor Switchgear

Contents. Page INTRODUCTION Power/Vac GUIDE FORM SPECIFICATION thru

The safest, most reliable Switchgear in the market today

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

SIEMENS. Series 8100oT Vacuum Controllers. www. ElectricalPartManuals. com. Bulletin CC

A comparison of metal-enclosed load interrupter (ME) switchgear and metal-clad (MC) switchgear

MV Metalclad Switchgear 4760V-15000V 20KA-63KA. AC Power Circuit Breaker Rating Structure. Test Procedures for Power Circuit Breakers

Product Specifications for Aluminum Vertical Break Switches

SecoVac * Ground & Test Device

BGE STRATEGIC CUSTOMER ENGINEERING

Selection and Application Guide E50001-U229-A320-X-US00. GM38 Switchgear. 38kV. Power Transmission & Distribution

Switchgear Skid, C1192

Design Standard. Purpose: Design Standard:

EMC 24 SERIES METAL CLAD SWITCHGEAR. We engineer, we assure. Up to 24 kv - 25 ka With Withdrawable, Air-Insulated, Medium Voltage Distribution Panel

Technical guide. Advance kv medium voltage, metal-clad switchgear

ADVAC - Advanced Design Vacuum Circuit Breakers Technical Guide

Medium voltage switchgear SafeGear HD 63 ka arc resistant metal-clad switchgear. ABB Group February 25, 2015 Slide 1

MESG 12 / 17.5 / 24 / 36 KV

Chapter 6 Generator-Voltage System

Power Break II Switchboard

Instructions for VCP-W Simple Electrical Ground & Test Device (SEG&TD) with simplified interlock scheme - bottom terminal set version

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

Three-Phase Pole Mounted Recloser

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

Cutler-Hammer INSTRUCTIONS FOR MAGNUM DS METAL-ENCLOSED LOW-VOLTAGE SWITCHGEAR ASSEMBLIES WITH MAGNUM DS BREAKERS IB E

Overview Brochure Integrated Power Distribution. Medium Voltage Assembly Solutions

7. SERVICES OVER 600 VOLTS

Operators/Accessories. Type V2-CA Aluminum. Vertical Break Switch. Ordering Information Furnish: Available Accessories. Standard Operator Features

Advance 27 ANSI 27 kv switchgear

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

Metal-Clad Indoor Switchgear

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

SM-1700 Secondary Shunt Trip Coil Assembly. Powered by Safety

Power/Vac OEM Express Switchgear

Detail Bill of Material Page 1 of 1 Project Name: Amphi School - MVS Replacement Negotiation No: TU700213X7K2 General Order

MEDIUM-VOLTAGE SWITCHGEAR

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV

Product Specifications for Phase Over Phase GOABS(r)

Solid Dielectric Load Break Switch SPECIFICATION. 25kV, 630A, 4 WAYS, 4 WAYS SWITCHED PADMOUNTED VACUUM LOAD INTERRUPTER

e 2 ALPHA Medium Voltage Switchgear K Catalogue EN

Outdoor Padmount Switching Products

GE CONSUMER & INDUSTRIAL

CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-112 SUBSTATION CLASS VACUUM CIRCUIT BREAKERS OCTOBER 2008

POWER-ZONE 4 Low Voltage Metal-Enclosed Drawout Switchgear with MASTERPACT NW Low Voltage Power Circuit Breakers

Safe and Reliable. Flexible, Compact Design. Easy Installation and Maintenance

MEDIUM VOLTAGE AIS ANSI SWITCHGEAR Advance and Advance 27. Non-arc-resistant MV ANSI switchgear

SERIES 802 / 812 SPECIFICATION 15KV & 25KV PADMOUNTED LIQUID-INSULATED VACUUM LOAD INTERRUPTERS AND FUSE ASSEMBLIES

Vacuum Circuit Breakers (Vehicle) Type MSV 5kV. Instructions Installation Operation Maintenance SGIM-9988

POWERCON CORPORATION

Solar Power Switchgear & Energy Storage Renewable Energy Systems

BHARAT HEAVY ELECTRICALS LIMITED, JHANSI

MASTERCLAD. Metalclad Indoor Switchgear 27 kv with Type VR Vacuum Circuit Breakers Class Instruction Bulletin. Retain for future use.

Controlled Power HSN High Speed DC Circuit Breakers

Simple Electrically Operated Ground & Test Device For use in Type VCP-W Switchgear rated up to 15kV, 25 and 40kA UPPER TERMINAL SET VERSION

SafeGear TM Motor Control Center Arc resistant metal-clad construction

Aluminum Vertical Break Switch kv A.

Submersible Vacuum Fault Interrupters

Vacuum Circuit Breakers (Vehicle) Type FSV 5kV to 15kV. Instructions Installation Operation Maintenance SGIM-9968

24kV Medium Voltage Switchgear Metal-Enclosed (LSC2A)

Electrical Switchgear Replacement Montgomery County Community College

Instruction Bulletin. DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 6035

Transcription:

POWERCON CORPORATION 38,000 VOLT METAL-CLAD SWITCHGEAR BROCHURE #PC-041 ELECTRONIC VERSION CREATED: 6/30/96 Powercon Corporation P.O. Box 477 1551 Florida Avenue Severn, Maryland 21144 Baltimore: 410-551-6500 Washington: 301-621-7400 Fax: 410-551-8451 email: info@powerconcorp.com

This bulletin describes Metal-Clad Switchgear - one of Powercon's switchgear product lines. This advanced switchgear line is completely factory built, wired and assembled. Each cubicle may contain the circuit breaker, bus bars, primary and secondary disconnecting devices, instrument transformers, instruments and relays, secondary wiring and other necessary components. The switchgear is designed so that additional circuit breaker or auxiliary cubicles may be added in the future. The Circuit Breaker: Vacuum interrupters with stored energy operating mechanism Primary disconnecting device Secondary disconnecting devices Auxiliary switches Ground contacts Control wiring Interlocks In addition to the standard equipment described, custom engineered switchgear is offered to meet individual purchaser needs. With a highly skilled professional engineering manufacturing team, an organizational entity has been developed to provide the material and services our customers require. The engineering staff - application product design - development - manufacturing - has achieved the extensive American National Standards Institute (ANSI) 70 East 40th Street New York, New York 10017 Metal-Clad Switchgear (For Guide Specifications - See Publication PC-029) Table 1 - Applicable Industry Standards system experience and knowledge required in the application, manufacture, delivery, and service of Power Systems Switchgear. This product is the result of seasoned technical efforts combined with the well versed, skilled, competent, veteran work force exerting their combined efforts to provide the best in service and equipment. Our membership in NEMA, ANSI and IEEE keeps us up to date on the ever changing standards so that we meet today's exacting demands. From the guidance of highly qualified engineering management focusing its attention on sound imaginative technical practices, has come the creative achievements and flexibility that has given Powercon a worldwide reputation for top quality switchgear and service. The proven performance of Metal-Clad Switchgear with vacuum circuit breakers is attested to by the great numbers of equipments that have seen service. Technical data such as dimensions, weights, shipping and miscellaneous information is available upon request from Powercon's sales department. Powercon reserves the right to make such changes finds necessary. National Electrical Manufacturers Association (NEMA) 2101 L Street N.W., Suite 300 Washington, D.C. 20037 Standard No Description Standard No. Description C37.04 CA High-Voltage Circuit Breaker Rating SG-2 High Voltage Fuses Structure C37.06 Preferred Ratings of AC High-Voltage Circuit Breakers C37.09 Test Procedures for AC High- SG-4 Power Circuit Breakers Voltage Circuit Breakers C37.010 Application Guide for AC High-Voltage Circuit Breakers C37.11 AC High-Voltage Circuit SG-5 Power Switchgear Assemblies Breakers Control Requirements C37.20.2 Switchgear Assemblies and Metal-Enclosed Bus C37.100 Definitions of Power Switchgear

Metal-Clad Switchgear Single Circuit Outdoor with Utility Metering

QUALITY FEATURES MAKE The Leader In Value Second To None! Powercon Switchgear, the leader in value, is designed and manufactured to: Maximize Safety - Quality - Reliability which in turn Minimizes exposure to Product Liability. In order to minimize such exposure Powercon provides: A Documented Quality Assurance Program. Product Liability - Quality Assurance - without one you have the other. Powercon's in depth application of the basic elements of Product Quality - Performance - Features Conformance - Reliability - Durability - Serviceability all meld together for excellence in Quality Assurance. Design & Conformance Testing in accordance with industry standards ANSI/IEEE C37.20.2. Only by successfully performing these rigorous tests on prototype equipment can a manufacturer be assured that the metal enclosed equipment will produce a switchgear assembly that will produce a switchgear assembly that would function safely and satisfactorily. Powercon has available test data ring its proper role in maintenance but providing preventive and predictive activities. In addition, of course, reliability is designed by specifying the best available materials, manufacturing, and design using only highly experienced personnel with strict quality control, tested in accredited laboratories. Continued customer usage has proven acceptance to the product. In order to assure the greatest possible reliability in the product, the product receives a continuous inspection during manufacture, demonstrating that its manufactured equipment has passed these tests Experience. Powercon's experience gained in over 30 years of supplying Power Distribution Switchgear for critical facilities such as computers, hospitals, airports, autos, aluminum, copper, steel, pharmaceutical, etc. and a host of other industries has resulted in a product that is superior to the existing standards and provides an unequaled cushion of protection, The Powercon Corporation manufactures switchgear that exceeds the norm for world class equipment. Safety - Quality - Reliability Product Liability factors now place greater emphasis on Quality - Reliability - & Safety which are primary concerns in switchgear. First, because quality represents the best long term value to customers. Second, because power continuity is a basic requirement in an industry which requires the highest of reliability of equipment and, Thirdly, because a high degree of safety is necessary when operating the switchgear. Reliability is designed into the equipment by not only considering thorough testing and thorough checking by Quality Assurance Supervision. An increase in safety has demanded that this switchgear be installed, operated, maintained, handled, etc. by Qualified Personnel. Detailed instruction books that are provided refer to safety standards and practices along with instructional details, all contribute to increased safety - quality - reliability.

Metal-Clad Switchgear Horizontal Drawout with A Super Structure: Powercon's design provides a ruggedness and greater structural strength which is in a class by itself. The jig welded members form an assembly to provide a plumb and square switchgear unit. This assures interchangeability of units and results in a minimum of installation time. 38kV vacuum breaker shown in the connected position within an outdoor Metal-Clad unit (48" wide unit) 38kV, 150KV BIL,1200A or 2000A 1. Relays and controls 2. Circuit breaker 3. 3-point door catches 4. Secondary connection handle 5. Channel base Front view circuit breaker cell 1. Sliding metal shutters (grounded) 2. Space heater 3. Stationary secondary contact block 4. Rack-in nut 5. Ground bus 6. interlock rail 7. Stationary Position Switch 8. Shutter Mechanism

Metal-Clad Switchgear Horizontal Drawout with A Super Structure: 38kV circuit breaker removed from cell 1. Mechanism manual charging port 2. Breaker stored energy mechanism shield 3. Manual close and trip buttons 4. Hand grip bar 5. Secondary connection handle (for use in test position) 6. Racking port 7. Foot pedal mechanical interlock 8. Track guide pin 9. Front swivel casters 10. Shutter activating roller (typical both sides) Rear view of 38kV vacuum breaker 1. Phase barriers 2. Primary studs and finger cluster 3. Vacuum interrupter unit 4. Primary studs and finger cluster 5. Rear wheel housing (typical) 6. TOC switch actuator plate 7. Horizontal racking screw 8. 15OKV BIL porcelain insulators 9. point secondary contact (sliding) 48 point (optional)

Metal-Clad Switchgear Horizontal Drawout with A Super Structure: Framework of welded steel Sheet steel enclosure, including a hinged front door, which may be used as an instrument panel Compartment and inter-unit barriers Three-phase insulated bus and connections Porcelain bus supports Stationary primary disconnecting devices Stationary secondary disconnecting devices Circuit breaker racking-in device See Guide Specification Publication PC 029 It Consists Of: Circuit breaker interlocking device Instruments and relays Control wiring Terminal blocks Instrument transformers Provision for connecting main cable Guide rail on floor of structure Wiring channels Control cut-outs The breaker, bus, potential transformers, current transformers and cables all have their own compartments. And, each function is isolated by rugged partitions. Powercon metal-clad provides the value of a superior insulation system at vital points, and greater structural strength from a rugged all-welded steel frame. Relays and instrumentation are mounted on the front of the unit door so that the breaker can be removed or inserted without damaging a relay. Guide rails are provided so that the breaker will roll into proper position in the cubicle. The mechanism assures perfect alignment when the breaker is racked into its operating position. Porcelain - The Ultimate in Insulation Enclosure Section View - 38kV Stationary Structure World Wide Service... Powercon Field Service Engineering Powercon's 24-hours-a-day field service is provided through factory Field Service Engineers. Our Field Service Engineers are highly skilled SWITCHGEAR experts extremely proficient in providing the highest quality service for switchgear and its components. Powercon is prepared to provide you with: Emergency repair Repair and maintenance services for existing or obsolete equipment Installation supervision of new equipment Advice and instruction of preventive maintenance procedures Coordination Check of new equipment In warranty service Other required installation and engineering services. Powercon Service Engineering is based at the manufacturing facility in Severn, Maryland, only 6 miles from the Baltimore- Washington International Airport. Our Service Engineering group is in close liaison with other Powercon engineers who create the application, and the mechanical and electrical design of each switchgear equipment. Powercon also maintains detailed records of every part and component manufactured and/or purchased for each project. They have immediate access to the purchasing staff for suppliers service.

Powercon s Power Lab & Quality Assurance Programs Provide Outstanding Performance Second to None... Documented Quality Assurance. The control of quality is a top management function and responsibility. Powercon has established a high quality tradition over many years. Constant vigilance and careful and workmanship combine to create rigid requirements for quality. The Quality Control Procedures used by Powercon have been in use since its inception. There have been additions required during the intervening years as more information and data was collected and the need arose to be more inclusive. The Quality Control Procedures are fully documented and eminate with the initial engineering designs. Because final quality must be assured, every complete equipment is tested at the factory for conformity to rigid standards verifying the mechanical and electrical specifications. The following are some of the tests made on Powercon switchgear, among many others. Final master fixture alignment of all mating and matching points, bushing matching; auxiliary contact mating; grounding shoe contact to assure operation. Auxiliary wiring check to assure correctness and continuity. This includes primary current injection primary voltage application control power to actually operate and synthesize the entire control and protective system, when required. All relays and devices given complete secondary power check by test consoles, when required. High potential tests of primary and secondary circuitry in accordance with ANSI standards. Final inspection. Powercon Corp. / P.O. Box 477 / 1551 Florida Avenue / Severn, MD 21144 Baltimore: 410-551-6500 / Washington: 301-621-7400 / TOLL FREE:1-800-638-5055 / FAX: 410-551-8451