Outdoor Padmount Switching Products
|
|
- Kellie Todd
- 6 years ago
- Views:
Transcription
1 Outdoor Padmount Switching Products Live-front & Dead-front 15 & 25 kv Switchgear, Fused Sectionalizing Enclosures, Metering and Capacitor Enclosures Rugged Outdoor Construction Safety and Security Features Long-Life Polymax Coating High Performance VersaRupter Switch
2 Outdoor Padmount Switching Products ABB s Padmount Switching Products represent over 30 years of quality design and manufacturing. The line includes live-front and dead-front loadbreak switches and fuses in multiple confi gurations in ratings up to 25 kv. With our quality construction and easy installation, we have earned our market position with reliable, easy to implement protection and control for underground electrical distribution networks. Our Padmount Switching Products incorporate the VersaRupter load interrupter switch. The Versa- Rupter uses an innovative puffer and nozzle system to quickly and effi ciently extinguish the arc of fullload interruptions, resulting in a compact, highperformance switch. Live-front switchgear 600 A, 15 and 25 kv (MES) Dead-front switchgear 600 A, 15 and 25 kv (MDS) Fused sectionalizing enclosures (ME series) for power fusing (MEP) and current limit fusing (MEC) 200 A, 15 and 25 kv Capacitor banks and metering enclosures Accessories The complete product line, which includes padmount switch enclosures and auxiliary products, such as metering stations and capacitor banks, are designed and built to meet rigorous utility industry specifi cations for years of reliable operation in harsh outdoor environments. Polymax premium coating and rugged construction meet or exceed ANSI Standard C for padmounted equipment enclosure integrity. 2 ABB
3 MES Live-front Switchgear 600 Ampere Load Switching 15 & 25 kv 40,000 Ampere Asymmetrical Momentary 40,000 Ampere Asymmetrical Fault Closing Enclosure footprint, termination height and switch/fuse configuration per industry standards Top-mounted horizontally spaced connecting bus contributes to ease of inspection and maintenance, prevents phase to phase dripping, and reduces potential for fl ashover Full height electrical grade (GPO-3) glass reinforced polyester phase separation barriers are easily removable without tools for easy installation and maintenance Industry leading phase spacing for improved access and safety Frame mounted switch and fuse for positive blade alignment Storage provisions for fuse holders/fuse end fi tting assemblies in fuse compartments Viewing windows in component compartment for easy verification of switch position Heavy-duty channelized steel construction with three-point door latching and security features Flexible modular design with an extensive selection of available options ABB 3
4 MDS Dead-front Switchgear 600 Ampere Load Switching 15 & 25 kv 40,000 Ampere Asymmetrical Momentary 40,000 Ampere Asymmetrical Fault Closing Switches and fuses are enclosed in a metal compartment for personnel safety and to prevent entrance of foliage and contaminants Enclosure footprint, termination height and switch/fuse configuration per industry standards Fuse access doors positively latched in the closed position and mechanically interlocked with 200 A elbows to prevent access until elbows are disconnected Fuses accessible only when fuse access doors have been disconnected and pivoted to the open service position Switch position visible through component compartment s viewing windows Switch terminals equipped with 600 A bushings and fuse terminals equipped with 200 A bushing wells in accordance with ANSI standards Flexible, modular design promotes life cycle support, fi eld upgrades and repairs 4 ABB
5 ME Series Dead-front Fused Sectionalizing Enclosures Power fusing (MEP) Current limiting fusing (MEC) 200 A kv Designed for 200 ampere circuits to protect and sectionalize a system Dead-front construction with metal partition separating cable terminating compartment from fuse compartment Single-phase switching using loadbreak inserts and elbow connectors or optional loadbreak fuse mounting Available in single and three-phase with one or two sources and one, two or three loads Bushing wells for 200 A standard, with optional 600 A source bushings Mountings available for all industry standard fusing Grounding provisions in each compartment Electrical grade (GPO-3) fi berglass barriers for phase separation ABB 5
6 Capacitor Banks Dead-front or live-front construction 15 and 25 kv 200 A bushing wells - Standard 600 A bushings - Optional Ratings up to 2400 KVAR System connections in grounded WYE or ungrounded WYE or delta options Fixed or switched system configurations Vacuum or oil capacitor switching Fusing options include group power fuses, group currentlimiting fuses and individual capacitor fuses Control wiring can be wired to terminal block or to meter socket with 4 or 6 Jaw configurations Control power transformer in oil or dry type or source externally Construction and coating meets ANSI requirements and RUS U-4 specifications 6 ABB
7 Primary Metering Enclosures Dead-front or live-front construction 15, 25, and 35 kv 200 A bushing wells - Standard 600 A bushings - Optional Multiple line and load confi gurations Grounding provisions in each compartment Electrical grade fi berglass barriers for phase separation Construction and coating meets requirements of ANSI and RUS U-4 specifi cations Available with ABB potential transformers and current transformers factory installed ABB 7
8 ABB Inc. 655 Century Point Lake Mary, FL Tel or Fax VAM2201-DB March 2008 Rev. B Copyright 2005, 2008 ABB. All rights reserved.
ME series dead-front fused sectionalizing enclosures MEC current limiting fusing and MEP power fusing 200 Amperes,15-25 kv
ME series dead-front fused sectionalizing enclosures MEC current limiting fusing and MEP power fusing 200 Amperes,15-25 kv ABB ME series fused sectionalizing enclosures ABB's dead-front Padmount ME series
More informationDescriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications
Descriptive bulletin Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications General overview Reliable, low maintenance and economical Load Interrupter
More informationVersaRupter 5-38 kv Load Interrupter Switch. Technical Guide
VersaRupter 5-38 kv Load Interrupter Switch Technical Guide NOTICE Components in this catalog are intended for use by switchgear assemblers engaged in original equipment manufacturing. All sales are subject
More informationMDS Dead-front Padmount Switchgear Style Guide 1VAM SG May 2010 Revision D
MDS Dead-front Padmount Switchgear Style Guide 1VAM224804-SG May 2010 Revision D The MDS style guide aids in the proper selection of your style number. When ordering the MDS, the style number must be given
More informationSWITCHGEAR DIVISION PRODUCT PROFILES
SWITCHGEAR DIVISION PRODUCT PROFILES Metal-Enclosed Load-Interrupter Switchgear Product Profiles Three-Phase, Group-Operated Load-Interrupter Switches with Fuses in Single and Multi-Bay Assemblies Manual,
More informationAdvance design OEM L-Frames, cell kits, & enclosures Metal-clad switchgear components OEM catalog & pricing
Advance design OEM L-Frames, cell kits, & enclosures Metal-clad switchgear components OEM catalog & pricing Introduction A modular system of switchgear building blocks and cassettes provide untouchable
More informationR-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A
R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A - 3700 A R-MAG The R-MAG is truly the next generation in vacuum circuit breakers, combining industry recognized magnetic
More informationTYPE PSI/II PADMOUNT SWITCHGEAR 15KV 25KV
Cutler Hammer SECTION PB-1A-110 PAGE 1 Replaces April, 1996 TYPE PSI/II PADMOUNT SWITCHGEAR 15KV 25KV The PSI/II Padmount is the second generation of switchgear in the PSI switchgear family. The PSI/II
More informationR-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism
R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism R-MAG Features: Low maintenance 10,000 mechanical operations (five times ANSI requirements) Simple magnetic actuator Vacuum interruption Definite
More informationDesign Build Deliver. Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak
Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak Powergrid Solution s Metal Enclosed Switchgear has many different customizable options and configurations. Customers
More informationMedium Voltage Metal-Enclosed Switches
Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Medium Voltage Switch MVS Product Description............................................. 2 Application Description..........................................
More informationLongest Life Product for Electric Furnace Applications! 100,000 Operations No Routine Maintenance Required!
DB 750-205 January 2007 Supercedes: December 2006 Now available with Vacuum Interrupter Monitor VBT Switch 15kV - 69kV VBU-T Switch 69kV - 230kV Longest Life Product for Electric Furnace Applications!
More informationMEH Series Sectionalizing Enclosures. Single-Phase and Three-Phase
MEH Series Sectionalizing Enclosures Single-Phase and Three-Phase ABB MEH Sectionalizing Enclosures ABB s MEH Sectionalizing Enclosures provide an economical and safe sectionalizing tap point for underground
More informationS&C Manual PME Pad-Mounted Gear
S&C Manual PME Pad-Mounted Gear Outdoor Distribution,. kv and 5 kv S&C Manual PME Pad-Mounted Gear... Featuring Elbow-Connected Encased Components. S&C Manual PME Pad-Mounted Gear brings in-air insulation,
More informationMedium Voltage Metal-Enclosed Switches
Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Introduction Product Selection Guide....................................2 Medium Voltage Switch MVS Product Description......................................
More informationSERIES 802 / 812 SPECIFICATION 15KV & 25KV PADMOUNTED LIQUID-INSULATED VACUUM LOAD INTERRUPTERS AND FUSE ASSEMBLIES
SERIES 802 / 812 SPECIFICATION 15KV & 25KV PADMOUNTED LIQUID-INSULATED VACUUM LOAD INTERRUPTERS AND FUSE ASSEMBLIES MANUALLY OPERATED / REMOTELY OPERATED DEAD FRONT PADMOUNTED SWITCHGEAR WITH VACUUM LOAD
More informationFEBRUARY 14, 2017 Elastimold Solid dielectric switchgear customer presentation
FEBRUARY 14, 2017 Elastimold Solid dielectric switchgear customer presentation Elastimold solid dielectric switchgear agenda Compelling value Design principles Product overview Switchgear applications
More informationMedium Voltage Outdoor Apparatus Portfolio 2009
PPMV, April/May 2009 Medium Voltage Outdoor Apparatus Portfolio 2009 May 5, 2009 Slide 1 Summary Reclosers Outdoor dead tank vacuum circuit breakers Outdoor live tank circuit breakers Pole mounted circuit
More informationME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position
LET S BE PACIFIC November 0 Volume Number 5 ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position Federal Pacific has the capability to engineer, fabricate and assemble
More informationMedium voltage switchgear SafeGear HD 63 ka arc resistant metal-clad switchgear. ABB Group February 25, 2015 Slide 1
Medium voltage switchgear SafeGear HD 63 ka arc resistant metal-clad switchgear ABB Group February 25, 2015 Slide 1 SafeGear HD arc resistant switchgear 63 ka arc resistant metal-clad air insulated switchgear
More informationDescriptive bulletin. ReliaGear ND ANSI narrow frame metal-clad switchgear
Descriptive bulletin ReliaGear ND ANSI narrow frame metal-clad switchgear Table of contents Introduction...3 Vmax/A breaker...4 Instrument transformers...5 Potential transformers...6 15 kv potential transformers...6
More information5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application
The most advanced Arc-Resistant Switchgear, designed and built to provide maximum safety in the event of an Internal Arcing Fault. 5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application Page 1
More informationME Series Fused Sectionalizing Enclosures Style Guide 1VAM SG April 16, 2009 Revision D
ME eries Fused ectionalizing Enclosures tyle Guide 1VM224701-G pril 16, 2009 Revision D 's dead-front padmount ME series fused sectionalizing enclosures are designed for 200 ampere circuits to protect
More informationTypical Specification
Engineered to Order Built to Last Typical Specification VAULT VRPFI, TWO POSITION, ROTARY PUFFER SWITCHGEAR PART 1- GENERAL 1.1 DESCRIPTION A. The switch shall consist of manually operated load interrupting,
More informationSIMOVAC and SIMOVAC-AR. Medium-voltage controllers 2.3 kv kv. usa.siemens.com/simovac
0000 00000 0000 000 0000 000000 00000 0000 00000 0000 000 0000 000000 00000 SIMOVAC and SIMOVAC-AR Medium-voltage controllers 2.3 kv - 6.9 kv usa.siemens.com/simovac 2 SIMOVAC and SIMOVAC-AR - the latest
More informationGuide Specification. Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break
Part 1-GENERAL 1.1 DESCRIPTION Guide Specification Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break The switchgear shall consist of magnetically actuated solid dielectric insulated
More informationSWITCHGEAR DIVISION PRODUCT PROFILES
SWITCHGEAR DIVISION PRODUCT PROFILES Metal-Enclosed Load-Interrupter Switchgear Product Profiles Description: Three-Phase, Group-Operated Load-Interrupter Switches with Fuses in Single and Multi-Bay Assemblies
More informationMetal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents
January 2003 Vol. 1, Ref. No. [1011] -1 Medium Voltage Metal-Enclosed Switches Contents Description Page MVS................................... -2 and Breaker MSB........................ -3 Metal-Enclosed
More information15-kV Wall-Mount Switchgear Three-Phase Indoor/Outdoor 600 Amp S&C Mini-Rupter Switch
Page 1 2015 Kinked roof prevents standing moisture Glass reinforced barriers meet NEMA GPO-3 Standards 0.625" diameter copper ground bar Elliott air-insulated bushings accept IEEE Standard inserts and
More informationVersaRupter MV Indoor Switch kv, A, 40 and 61 ka Momentary Price and Order Entry Guide ABB
VersaRupter MV Indoor Switch 5 38 kv, 200 1200 A, 40 and 61 ka Momentary Price and Order Entry Guide ABB Table of Contents VersaRupter Overview General Description..........................................................
More informationMEDIUM VOLTAGE AIR INSULATED ARC-RESISTANT LOAD BREAK AND DISCONNECT SWITCHES
MEDIUM VOLTAGE AIR INSULATED ARC-RESISTANT LOAD BREAK AND DISCONNECT SWITCHES Description JRS arc-resistant fused/non-fused load break and fused/non-fused disconnect switches are available for applications
More informationINDEX Welcome 1.2 Contacting Powergrid Solutions, Inc. 1.3 Terms Of Usage 1.4 Product Codes and Descriptions
INDEX SECTION 1 INTRODUCTION 1.1 Welcome 1.2 Contacting Powergrid Solutions, Inc. 1.3 Terms Of Usage 1.4 Product Codes and Descriptions SECTION 2 PADMOUNTED ENCLOSURES/CABLE SWITCHING/TERMINATING GEAR
More information15-kV Live Terminal 600 Amp Group Operated Pad-Mounted Metal-Enclosed Outdoor Switchgear 140 Amp (Max) Clip Mount Current-Limiting Fuses
Page 1 2015 Heavy duty 11-gauge steel enclosure is all-welded construction for long life Corrosion proof nameplate is located to provide easy access for the operator Glass reinforced barriers meet NEMA
More informationPadmount Solid Dielectric Switchgear Catalog
Padmount Solid Dielectric Switchgear Catalog p G&W headquarters in Bolingbrook, IL USA Company Profile Since 1905, G&W Electric has helped energize the world with innovative power system solutions. With
More informationSolid Dielectric Load Break Switch SPECIFICATION. 25kV, 630A, 4 WAYS, 4 WAYS SWITCHED PADMOUNTED VACUUM LOAD INTERRUPTER
Solid Dielectric Load Break Switch SPECIFICATION 25kV, 630A, 4 WAYS, 4 WAYS SWITCHED PADMOUNTED VACUUM LOAD INTERRUPTER MANUALLY OPERATED / REMOTELY OPERATED DEAD FRONT PADMOUNTED VACUUM LOAD INTERRUPTING
More informationSpecification Pad-Mounted Capacitor Bank with Dual Fusing Integral Load-Interrupter on Line-Side Fuse Mountings
Page 1 Specification Pad-Mounted Capacitor Bank with Dual Fusing Integral Load-Interrupter on Line-Side Fuse Mountings I. General This specification covers the design requirements for a pad-mounted capacitor
More informationQ pole Pole Mounted Capacitor System
Q pole Pole Mounted Capacitor System Introduction The ABB Qpole pole mount capacitor system is an economical solution for shunt reactive compensation on overhead distribution networks. The Qpole is suitable
More informationSTANDARD SPECIFICATION FOR TYPE PLD LIVE-FRONT/DEAD-FRONT PAD-MOUNTED SWITCHGEAR 15kV 25kV A. General
Page 1 STANDARD SPECIFICATION FOR TYPE PLD LIVE-FRONT/DEAD-FRONT PAD-MOUNTED SWITCHGEAR 15kV 25kV A. General 1. Product The pad-mounted switchgear shall be in accordance with the applicable plans, drawings,
More informationSpecifications. S&C Power Fuses Types SM and SMLa. For use with SM Refill Units or SMU Fuse Units. Indoor Distribution (4.16 kv through 34.
S&C Power Fuses s SM and SMLa Indoor Distribution (4.16 through 34. ) For use with SM Refill Units or SMU Fuse Units Specifications Conditions of Sale STANDARD: Seller s standard conditions of sale set
More information1VAL2401-SG Rev D. Spare parts list for Outdoor Products Reclosers, breakers, & padmount switches
1VAL2401-SG Rev D Spare parts list for Outdoor Products Reclosers, breakers, & padmount switches Reclosers GridShield recloser 12A00736H05 Actuator assist capacitor Single-phase upgrade 15 KV, 800 A, 12.5
More information100 / 110 DRYWELL FUSE SPECIFICATION
100 / 110 DRYWELL FUSE SPECIFICATION 15KV & 25KV SUBMERSIBLE VACUUM LOAD INTERRUPTERS AND DRYWELL FUSE ASSEMBLIES MANUALLY OPERATED / REMOTELY OPERATED SUBMERSIBLE SWITCHGEAR WITH LOAD INTERRUPTING SWITCHES
More informationAdvance 27 ANSI 27 kv switchgear
Advance 27 ANSI 27 kv switchgear Table of contents Advance 27...3 AMVAC breaker...4 Instrument transformers...5 Current transformers...5 27 kv voltage transformers...6 Distribution protection and control...7
More informationHorizontal Circuit Switchers
> Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving
More informationCPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards
Medium Voltage Switchgear Primary Distribution CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka General description Presentation Ormazabal s CPG System includes the CPG.1
More informationDEAD-FRONT PAD-MOUNTED SWITCHGEAR 15kV 25kV
TYPE PSE MANUAL DEAD-FRONT PAD-MOUNTED SWITCHGEAR 15kV 25kV Figure 1 Federal Pacific Dead-Front PSE (available as UL Listed) contains an integrated system of fuses and switches with access control features
More informationUsing new Magnetically Actuated Vacuum Interrupter technology for safe and reliable medium voltage circuit breaker switching in mines
Using new Magnetically Actuated Vacuum Interrupter technology for safe and reliable medium voltage circuit breaker switching in mines Abstract: The development of the magnetically actuated vacuum interrupter
More informationC1000 Series Automatic Cap Bank
C1000 Series Automatic Cap Bank Metal Enclosed - Medium Voltage Capacitors Assemblies Fixed / Auto Medium Voltage 5, 15, 25 and 35 kv Class Customized to your specifications The Reactive Power Solution
More information7. SERVICES OVER 600 VOLTS
7. SERVICES OVER 600 VOLTS 7.1 GENERAL The Company shall always be consulted to obtain required design criteria where service is contemplated.preliminary plans of the Customer shall be submitted for review
More informationDescriptive Bulletin. R-MAG TM magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv
Descriptive Bulletin R-MAG TM magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv Introduction The R-MAG TM is truly the next generation in medium voltage vacuum circuit breaker
More informationMEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE - B - C - en - REV
MEDIUM VOLTAGE MEDIUM VOLTAGE APPLICATION CE-B Metal Clad switchboards are designed for use in public and industrial distribution system up to 24kV for the operation and protection of lines, generators,
More informationDescriptive Bulletin. R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv
Descriptive Bulletin R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv Introduction The R-MAG is truly the next generation in medium voltage vacuum circuit breaker technology.
More informationSERIES G100 / G110 SPECIFICATION 15KV & 25KV SUBMERSIBLE & VAULT MOUNTED SF 6 -INSULATED VACUUM LOAD INTERRUPTING SWITCHES
SERIES G100 / G110 SPECIFICATION 15KV & 25KV SUBMERSIBLE & VAULT MOUNTED SF 6 -INSULATED VACUUM LOAD INTERRUPTING SWITCHES MANUALLY OPERATED / REMOTELY OPERATED DEAD FRONT SUBMERSIBLE AND VAULT MOUNTED
More informationHorizontal Circuit Switchers
> Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving
More information35-kV Safefront 200 Amp SuperWell Primary Capacitor Station Pad-Mounted Outdoor
Page 1 2016 EPM-PCS-35-320P-R2/ESW-GCM6-2S-SA Three Phase Two Ways per Phase 200 Amp 35 kv Class Eaton's CPS LRTPs 35 kv Elliott Air-Insulated SuperWell Bushings 21.1/36.6 kv Grounded Wye Max Design, 150
More information15-kV Safefront 200 Amp Primary Capacitor Station Pad-Mounted Outdoor
Page 1 2015 Heavy-duty 11-gauge steel enclosure is all-welded construction for long life Clear polycarbonate removable safety barrier separates upper and lower compartment (supplied only with internally
More informationUnderground Distribution Switchgear
Underground Distribution Switchgear Functional Specification Guide Functional Specification for 15 kv, 25 kv, or 35 kv Underground Distribution Switchgear 1. Scope 1.1. This specification applies to three-phase,
More informationBrochure. Modular Systems wind portfolio Power Collection and Grid Connection products
Brochure Modular Systems wind portfolio Power Collection and Grid Connection products Wind portfolio Background ABB is one of the few suppliers that has been deeply involved in wind power segment development,
More informationSafeGear TM Motor Control Center Arc resistant metal-clad construction Motor Control Center Descriptive bulletin
SafeGear TM Motor Control Center Arc resistant metal-clad construction Motor Control Center Descriptive bulletin Contents 1. Introduction 2 2. Product highlights 2 3. Available configuration/competitive
More informationIndoor or Outdoor 2400 to 14,400 Volts 600 to 14,400 Kvac, 3 Phase, 60 Hz
c February, 1979 Supersedes DB 39-485, pages 1-4, dated November, 1973 Mailed to: E, D, C/2001, 2002/DB Benefits There are many capacitor applications in which factors such as physical location, personnel
More informationSpecifications. S&C Alduti-Rupter Switchesa Indoor Distribution (4.8 kv through 34.5 kv) Conditions of Sale SPECIAL TO THIS PRODUCT: How to Order
S&C Alduti-Rupter Switchesa Indoor Distribution ( kv through kv) Specifications Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 0 apply. SPECIAL TO THIS PRODUCT:
More informationOPERATION AND MAINTENANCE OF TRAYER 3000 SERIES PADMOUNTED VACUUM FAULT INTERRUPTER
OPERATION AND MAINTENANCE OF TRAYER 3000 SERIES PADMOUNTED VACUUM FAULT INTERRUPTER 1) INTRODUCTION 2) CAUTIONS 3) RECEIVING A) UNPACKING B) INSPECTION C) HANDLING D) STORAGE 4) INSTALLATION A) PRE-INSTALLATION
More informationS&C Loadbuster Disconnects
S&C Loadbuster Disconnects Outdoor Distribution ( kv through 34.5 kv) With these outstanding features... Up to -ampere continuous ratings, 40,000-ampere RMS asymmetrical momentary ratings Designed for
More informationWLI Medium Voltage Switchgear Renewal Parts
Page 1 Supersedes Renewal Parts Data, pages 1-2, dated June 1992, WLI Medium Voltage Switchgear Renewal Parts Page 2 Standard Manually Operated Fused WLI Switch ➇ ➁ ➀ ➂➃ WLI Switch Mechanism ➉ ➈ m Replacement
More informationOPERATION AND MAINTENANCE OF TRAYER 4000 SERIES PADMOUNTED VACUUM FAULT INTERRUPTER
OPERATION AND MAINTENANCE OF TRAYER 4000 SERIES PADMOUNTED VACUUM FAULT INTERRUPTER 1) INTRODUCTION 2) CAUTIONS 3) RECEIVING A) UNPACKING B) INSPECTION C) HANDLING D) STORAGE 4) INSTALLATION A) PRE-INSTALLATION
More informationyour Green Power WIND POWER SOLUTIONS only Greener
your Green Power WIND POWER SOLUTIONS only Greener WIND POWER SOLUTIONS Thomas & Betts is committed to being your partner in power delivery by leading the industry in innovative wind power solutions and
More information15-kV Safefront Mini-Switch Source Isolated Pad-Mounted Switchgear 140 Amp (Max) Clip-Mounted Current-Limiting Fuses
Page 1 2016 Heavy duty 11-gauge steel enclosure is all-welded construction for long life 200 Amp Elliott air-insulated bushing wells accept IEEE Standard inserts and elbows ushing wells may be added or
More informationDESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5
DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 1.1. APPLICABLE PUBLICATIONS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements, and errata), form a part of this
More informationAir-insulated switchgear UniGear type ZS1
Air-insulated switchgear UniGear type ZS1 ABB Power Technologies / 1-7074 D 12-03-2003 - Air-insulated switchgear UniGear type ZS1 ABB Power Technologies / 2-7075 D 1 2-03-2003 - Rated voltage kv 12 17.5
More informationDetail Bill of Material Page 1 of 1 Project Name: Amphi School - MVS Replacement Negotiation No: TU700213X7K2 General Order
Amphitheater High School Medium Voltage Switchgear Replacement Basis of Design 8/21/17 1of3 Detail Bill of Material Page 1 of 1 Project Name: Amphi School - MVS Replacement Negotiation No: TU700213X7K2
More informationSpecifications. S&C Alduti-Rupter Switches with Power Fuses Outdoor Distribution (14.4 kv through 46 kv)
Outdoor Distribution (4.4 kv through 46 kv) Specifications Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 50 apply, except as modified under WARRANTY QUALIFICATIONS
More informationTRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES
TSEWG TP-11: UFC 3-500-10N BEST PRACTICES UFC 3-500-10N was developed by NAVFAC and was used as the starting point for the tri-services development of UFC 3-500-10, Design: Electrical Engineering. UFC
More informationChapter 6 Generator-Voltage System
Chapter 6 Generator-Voltage System 6-1. General The generator-voltage system described in this chapter includes the leads and associated equipment between the generator terminals and the low-voltage terminals
More informationSPECIFICATION BULLETIN
SPECIFICATIONS Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 150 apply, except as modified under WARRANTY QUALIFICATIONS on page 3. SPECIAL TO THIS PRODUCT:
More informationZX-Family Gas-insulated medium voltage switchgear
ZX-Family Gas-insulated medium voltage switchgear Minimum overall costs ZX offers maximum economy The compact design of the panels reduces the space required and therefore the size of the station. Freedom
More information15-kV Live Terminal 200 Amp Mini-Switch Source-Isolated Pad-Mounted Switchgear 40 Amp (Max) Arc-Strangler NX Fuses
Page 1 2015 Heavy duty 11-gauge steel enclosure is all-welded construction for long life Door safety barrier removal instructions Safety latches on the door safety barriers, front and rear, are insulating
More informationSTANDARD SPECIFICATION FOR PAD-MOUNTED CAPACITOR BANKS FOR 15kV or 25kV APPLICATIONS
A. General 1. Product The pad-mounted capacitor banks shall be in accordance with the applicable plans, drawings, and one-line diagrams and shall conform to these specifications. 2. Assembly The outdoor
More information35-kV Safefront SuperWell Mini-Switch Source Isolated Pad-Mounted Switchgear 50 Amp (Max) Clip-Mounted Current Limiting Fuses
Page 1 2016 EPMR-35-311S-R2/ESW-CM9 Three Phase Two Ways per Phase 200 Amp 35 kv Class Eaton s CPS LRTPs 50 Amp (Max) 27 kv Clip-Mounted NX Fuse Provisions 21.1/36.6 kv Grounded Wye Max Design, 150 kv
More informationS&C Mini-Rupter Switches Application The Standard Mounting Arrangement Scheme for S&C Mini-Rupter Switches Typical ED, reduced from full 11 size.
S&C Mini-Rupter es Indoor Distribution (4.16 kv through 25 kv) Selecting Standard Mounting Arrangements for Manually Operated Styles Application The Standard Mounting Arrangement Scheme for S&C Mini-Rupter
More informationDISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus
DISTRIBUTION SOLUTIONS GSec Gas-insulated switching and isolating apparatus GSec is a three-position SF6 gas-insulated switchdisconnector designed for use in medium voltage switchgear for secondary distribution
More informationPOWERCON CORPORATION
POWERCON CORPORATION 38,000 VOLT METAL-CLAD SWITCHGEAR BROCHURE #PC-041 ELECTRONIC VERSION CREATED: 6/30/96 Powercon Corporation P.O. Box 477 1551 Florida Avenue Severn, Maryland 21144 Baltimore: 410-551-6500
More informationABB. Replacement Components
Replacement Components Low Voltage Switchgear & Power Circuit Breakers Medium Voltage Switchgear & Circuit Breakers Medium Voltage Switches & Motor Controls Distribution Breakers ABB Customers Choose ABB
More informationApproved Contractor Construction e-guide Residential Commercial
Approved Contractor Construction e-guide Residential Commercial Clark Public Utilities PO Box 8900 Vancouver, WA 98668 (PAGE 2) TABLE OF CONTENTS PAGE Trenching 3 Wire 8 Single-Phase Transformer Set 13
More informationWind Power Solutions. Make Energy Renewable and Reliable!
Wind Power Solutions Make Energy Renewable and Reliable! Reliable Thomas & Betts Products for Clean, Green, Thomas & Betts makes all the products that connect and protect a wind farm and its power distribution
More informationType MOST oil switch
Underground Distribution witchgear CA285002EN Effective October 20 upersedes 285-20 October 2013 COOPER POWER ERIE ype MO oil switch Contents Description Page General...2 Ordering information....2 Features
More informationDead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability
Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability ABB innovations for changing demands ABB (www.abb.com) is a leader in power and automation technologies that enables utility
More informationSafeGear Motor Control Center Arc Resistant Metal-Clad Construction Descriptive Bulletin
2017 SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Descriptive Bulletin SafeGear Motor Control Center Arc resistant Metal-Clad construction Descriptive Bulletin Table of Contents
More informationMetal-enclosed medium-voltage power factor correction system
Technical Data TD02607011E Supersedes June 2011 Metal-enclosed medium-voltage power factor correction system Contents Description Page Medium-voltage power factor correction... 1 Product description...
More informationEMPAC Metal enclosed capacitor bank for wind applications
EMPAC Metal enclosed capacitor bank for wind applications Introduction The EMPAC is a Metal Enclosed Capacitor Bank suitable for voltages between 1 kv and 36 kv for reactive compensation in MV networks
More informationABB Components. Switchgear, Distribution Breakers and Reclosers
ABB Components Switchgear, Distribution Breakers and Reclosers Meeting Customer Needs As a winner of ABB s prestigious Customer Focus Achievement Award and the Award of Excellence, the Components Group
More informationSafeGear TM Motor Control Center Arc resistant metal-clad construction
SafeGear TM Motor Control Center Arc resistant metal-clad construction Contents Description 2 SafeGear TM MCC applications 3 Electrical features 3 Standards 3 Standard service conditions 4 HCV vacuum contactor
More informationUNDERGROUND SERVICES - SECONDARY
UNDERGROUND SERVICES - SECONDARY Contents - Underground Services... U-1 General Requirements for Underground Service...U-2 Names of Parts for Underground Service... U-3 Service Termination in a Service
More informationUnderground Distribution Switchgear
Underground Distribution Switchgear Functional Specification Guide Functional Specification for 15 kv, 25 kv, or 35 kv Underground Distribution Switchgear 1. Scope 1.1. This specification applies to three-phase,
More informationMedium Voltage Equipment 5-15 kv GM-SG and 38 kv GM38 Metal-Clad Switchgear General
13 SWITCHGEAR Medium Voltage Equipment -1 kv GM-SG and 38 kv GM38 Metal-Clad Switchgear General Overview Features Siemens, 7, 1 and 38kV class medium voltage, one- or two-high vacuum circuit breaker switchgear
More informationProduct Selection Guide
Oil-Submersible Backup Fuses Full-Range CL Fuses External Backup Fuses Molded Fuse Products Product Selection Guide Introduction Electric distribution systems demand high levels of reliability, and flexibility
More informationSpecification Number: Product Name: GROUP MOUNTED MAIN FUSIBLE SWITCH, GROUP MOUNTED BRANCH FUSIBLE SWITCH (LONG) SECTION
Specification Number: 26 24 13.20 Product Name: GROUP MOUNTED MAIN FUSIBLE SWITCH, GROUP MOUNTED BRANCH FUSIBLE SWITCH (LONG) SECTION 26 24 13.20 SWITCHBOARDS (Long) Main Disconnect Group Mounted Fusible
More information35-kV Safefront Mini-Switch Source Isolated Pad-Mounted Switchgear 50 Amp (Max) Clip-Mounted Current-Limiting Fuses
Page 1 2016 Heavy duty 11-gauge steel enclosure is all-welded construction for long life 11-gauge steel equipment plate is rigid for easier elbow operation Parking stands for the upper two phases extend
More informationPAD-MOUNT SWITCHGEAR 15kV 25kV 35kV
PAGE 1 TYPE PSI PAD-MOUNT SWITCHGEAR 15kV 25kV 35kV INSTRUCTIONS For Installation and Operation INTRODUCTION... 1 Receiving... 1 Handling... 1 Storage... 1 GENERAL DESCRIPTION... 1 SAFETY FEATURES... 1
More information2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards
1 General 1.1 Switchboards shall be U.L. listed and labeled. 1.2 Each switchboard shall have its own main disconnecting means unless it is located in the same room as its source of origin. In most cases
More informationZX2 Gas-insulated medium voltage switchgear
Gas-insulated medium voltage switchgear Double busbar 13 8 10 12 11 10 9 8 7 2 1 3 4 5 6 2 Versatile Partitioned single or double busbar system for all applications even with the most demanding parameters
More informationABB Components. Switchgear, Distribution Breakers and Reclosers. ABB Power Distribution
ABB Components Switchgear, Distribution Breakers and Reclosers ABB Power Distribution Meeting Customer Needs As a winner of ABB s prestigious Customer Focus Achievement Award and the Award of Excellence,
More information