V5011N Two-Way Threaded Globe Valve

Similar documents
V5011N Two-Way Threaded Globe Valve

ML7421A,B Electric Linear Valve Actuator

D690 Round Damper LOW-LEAKAGE, SINGLE-BLADE FEATURES APPLICATION PRODUCT DATA. Contents

V5013B,C,F Three-Way Mixing and Diverting Valves

Q5020A-D Globe Valve Linkages FOR DIRECT COUPLED ACTUATORS

V5013N Three-Way Threaded Globe Valve

ML6420, ML7420 Non-Spring Return Electric Linear Valve Actuators

V5197A Firing Rate Gas Valve

V5013N Three-Way Threaded Globe Valve

AT120A-E; AT140A-E; AT150A,B,D-F; AT160B; AT175A-D,F Transformers

The ES /118 Explosion-Proof Housings

V51E Butterfly Valve. The valve mechanism is equipped with strain release springs.

ML6425, ML7425 Spring Return Electric Linear Valve Actuators

Immersion Wells and Compression Fittings FOR TEMPERATURE CONTROLLERS

L404F,T,V PressureTrol Controllers

Thermal Expansion Absorber For Potable Water TX SERIES TANKS

ML6420, ML7420 Non-Spring Return Electric Linear Valve Actuators

FEATURES APPLICATION PRODUCT DATA

V4062A,B,D HI-LO-OFF Fluid Power Gas Valve Actuator

VGF Flanged Globe Valves

V5011A,B,F,G,H,J Single-Seated Valves

V5049A FLANGED LINEAR VALVE PN25/40

MS4120F, MS4620F, MS8120F, S2024-F, S20230-F Fast-Acting, Two-Position Actuators

Immersion Wells and Compression Fittings FOR TEMPERATURE CONTROLLERS

Series 41 and 81 Modutrol IV Motors

V5050A,B FLANGED LINEAR VALVE PN16 AND PN25/40

V5055A-F Industrial Gas Valves

C7046A,B,C,D Air Temperature Sensors

VB-9213 Series. Application. Features. Applicable Literature

Q5024A,B Globe Valve Linkages FOR DIRECT COUPLED ACTUATORS

VB-9323 Series. Application. Features. Applicable Literature. 2-1/2" to 6" 125 Lb. Flanged Three-Way Diverting Valves General Instructions

BCS Modutrol Motor M7484A

V5050A,B FLANGED LINEAR VALVE PN16 AND PN25/40

VB-9313 Series. Application. Features. Applicable Literature

V9055A,D Modulating Fluid Power Gas Valve Actuator

Flowrite 599 Series Two-Way Valves, 1/2 to 2- inch Bronze Body, ANSI 250

Q7800C Integrated Burner Control Subpanel

VB2, VB3 Ball Valve/Actuator Assemblies

VB-9313 Series. Application. Features. Applicable Literature

Q345A, Q3451, Q3481, Q348A, Q348B, Q362A, Q373A, Q381A and Q3452 Intermittent Pilot Burner/Igniter-Sensors PRODUCT DATA

Flowrite 599 Series Two-Way Valves, 1/2 to 2- inch Bronze Body, ANSI 250

Flowrite 599 Series Two-Way Valves 1/2 to 2-inch Bronze Body

Series 71, 72, and 76 Modutrol IV Motors

Flowrite 599 Series Three-Way Valves 1/2 to 2-inch Bronze Body

Flowrite 599 Series Three-Way Valves 1/2 to 2-inch Bronze Body

Flowrite VF 599 Series Three-Way Valves 1/2 to 2-inch Bronze Body

T100A,F,M Controllers

R182J, R482J, R845A, R847A, R882J, RA89A, RA832A Switching Relays

Flowrite VF 599 Series Two-Way Valves 2-1/2 to 6-inch Flanged Iron Body

MS4104, MS4109, MS4604, MS4609, MS8104, MS8109 Fast-Acting, Two-Position Actuators

C7170A,B Encapsulated Temperature Sensor

35 and 70 lb-in. Non-Spring Return Direct Coupled Actuators ML6161, ML7161, ML6174, ML7174

Powers Controls Powertop Two-Way Valves Normally Open

Powers Controls Powermite Two-Way Flared Valves Normally Open/Normally Closed

Flowrite VF 599 Series Two-Way Valves 2-1/2 to 6-inch Flanged Iron Body

VE VVG Series Electronic Two-way Valves Normally Closed

Q345A, Q3451, Q3481, Q348A, Q348B, Q362A, Q373A, Q381A and Q3452 Intermittent Pilot Burner/Igniter-Sensors

UV100A Ultraviolet Systems UV100A1000 AND UV100A1018 AIR TREATMENT SYSTEMS UV100A1059 AND UV100A2008 SURFACE TREATMENT SYSTEMS

AV-430. Application. Features. Applicable Literature. Valve Linkage for Pneumatic Actuators General Instructions

Flowrite VF 599 Series Two-Way Valves 2-1/2 to 6-inch Flanged Iron Body

Series W&T Pneumatic Control Valve Type RVG Globe valve and angle valve

VB-8000 Series VB-9313 Series. Selection Guide. Applications. Applicable Literature. Selection Guide Contents. Valve and Actuator Selection Procedure

T 8053 EN Type and Type Pneumatic Control Valves Type 3252 High-pressure Valve

VG7000 Series Bronze Control Valves

3-way 1/2-2 Globe Valves

AV-497. Application. Features. Valve Linkage for MK-6811 and MK-6911 General Instructions

V4043 and V4044 Motorized Valves

Series 240 Type and Type Pneumatic Control Valves Type 3248 Cryogenic Valve

V January 2016 SINGLE SEATED V5011 SERIES. Previously manufactured by Dezurik and Honeywell

599 Series Zone Valve Bodies:

Powermite 599 Series MT Series Terminal Unit Two-way Valves

Type and Type Pneumatic Control Valves Type 3510 Micro-flow Valve

Y-Pattern Valve for Proportional Control Type 2632

VersaFlow Mag 3000 Electromagnetic Flow Sensor Technical Datasheet. Specification

2-Way & 3-Way Non Spring Return Characterized Ball Valves

Flowrite 599 Series. Technical Bulletin. 1/2 to 2-Inch Valve (2-Way & 3-Way) and Actuator Assembly Selection. Document No.

VersaFlow Mag 4000 Electromagnetic Flow Sensor Technical Datasheet. Specification

Flowrite 599 Series High Pressure Close-Off 2-Way Valves, 2-1/2 to 6-Inch, Flanged Iron Body, ANSI Classes 125 & 250

M436A/M836A,B Damper Motors

ML7420A/ML7425A,B. Honeywell. Electric Linear Valve Actuator FEATURES SPECIFICATIONS GENERAL SPECIFICATION DATA

Spare Parts List Series VP04 Pneumatic Remote Control Valve

VG7000 Female Threaded Cast Bronze Valve Series with Electric Actuators

Flare Valves 1/2 inch 2-Way and 3-Way

High Pressure 2-way 2 1/2-6 Globe Valves

MK-6600 Series, MK-6800 Series, and MK-6911

V4062A,B,D HI-LO-OFF Fluid Power Gas Valve Actuator

7 NK 72 en Issue 12/99 LIMIT SWITCHES. Series NK700 INSTALLATION, MAINTENANCE AND OPERATING INSTRUCTIONS

Type 289RC Exhaust Booster

COMMERCIAL. Product PRofile

Mounting and Operating Instructions EB 5868/5869 EN

Series 240 Pneumatic Control Valve Type DWA, -7 DWA, -9 DWA Globe Valve Type 3241 DWA

Powermite 599 Series MT Series Terminal Unit Three-way Valves

Series 240 Type and Type Pneumatic Control Valves Type 3248 Cryogenic Valve

Electronic Globe Valve Guide Specifications

VG2000 Series Electric Cast Iron Flanged Globe Valves

VE Series. Class "A" Gas Valves. Product handbook APPLICATION CONTENTS. General. Technical. Installation and operation. Various

MS Application. Features. Proportional Valve Actuator General Instructions

FRP Ball Valves INSTALLATION & MAINTENANCE MANUAL

AK Application. Features. Applicable Literature. Positive Positioner Pneumatic Relay General Instructions

VT Series Terminal Unit Valves 1/2 inch, 2-Way and 3-Way ANSI Class 250 Body Rating

Transcription:

VN Two-Way Threaded Globe Valve FEATURES PRODUCT DATA Red brass body with NPT-threaded end connections. Low seat leakage rate (. percent C v ). : rangeability per VDI/VDE 7. Spring-loaded, self-adjusting packing. Accurate positioning to ensure state of the art temperature control. Directly coupled electric and pneumatic actuators for easy mounting. Sizes range from / inch to inches. Valve designs provide equal percentage flow characteristic for water and linear flow characteristic for steam. Stainless steel stem and metal-to-metal seats. APPLICATION Repack and rebuild kits for field servicing. The VN is a two-way threaded globe valve that controls steam, water, and glycol solutions (up to percent concentration) in heating or cooling HVAC applications. The valve is used in two-position and modulating control systems. The valve is not suitable for combustible gas service. Contents Application... Features... Specifications... Ordering Information... Installation... Checkout... U.S. Registered Trademark Copyright 998 Honeywell Inc. All Rights Reserved 6-48

VN TWO-WAY THREADED GLOBE VALVE SPECIFICATIONS IMPORTANT The specifications given in this publication do not include normal manufacturing tolerances. Therefore, an individual unit may not exactly match the listed specifications. Also, this product is tested and calibrated under closely controlled conditions and some minor differences in performance can be expected if those conditions are changed. Models: VN Valve: Two-way threaded globe valve for steam, water, or glycol. NPT-threaded pipe connections. Throttling plug provides equal percentage characteristic of flow for water (VNxxx, VNxxx), linear characteristic of flow for steam (VNxxx). VNxxx and VNxxx are direct acting (stem down to close) VNxxx is reverse acting (stem up to close). Valve Sizes and Flow Capacities: See Table. Table. Valve size and flow capacities. Valve Body Pipe Size (in.) Flow Capacity (C v ) /.7 /.6 /.8 /.9 / 4.7 /4 7..7 -/4 8.7 -/ 9. 46.8 Pipe Connections: Female NPT-threaded connections. Seat: Stainless steel, replaceable (except VNxxx /4 in. to - /4 in. which have integral brass seat). ANSI Body Class: psi. Stem: Stainless steel. Plug: Brass on VNxxx and VNxxx for water; stainless steel on VNxxx for steam. Stroke: /4 in. ( mm). Approximate Leakage Rate:. percent C v. Pattern: -way, straight-through. Body Material: Red brass. Packing: Spring-loaded, carbon fiber reinforced PTFE V-rings. Pressure-Temperature Ratings: Water: 6 F to 48 F, 7 psi. 48 F to 4 F, psi. Steam: psi at 4 F. Valve Flow Characteristics: Water: equal percentage flow characteristic (VNxxx, VNxxx). Steam: linear flow characteristic (VNxxx). See Fig.. Close-Off Pressure Ratings: See Fig. and Tables and. ORDERING INFORMATION When purchasing replacement and modernization products from your TRADELINE wholesaler or distributor, refer to the TRADELINE Catalog or price sheets for complete ordering number. If you have additional questions, need further information, or would like to comment on our products or services, please write or phone:. Your local Home and Building Control Sales Office (check white pages of your phone directory).. Home and Building Control Customer Logistics Honeywell Inc., 88 Douglas Drive North Minneapolis, Minnesota 4-486 (6) 9- In Canada Honeywell Limited/Honeywell Limitée, Gordon Baker Road, North York, Ontario MH N7. International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A. 6-48

VN TWO-WAY THREADED GLOBE VALVE PERCENTAGE STEM TRAVEL 9 8 7 6 4 FLOW CHARACTERISTICS EQUAL PERCENTAGE LINEAR 4 6 7 8 9 PERCENTAGE FLOW M97 Fig.. Equal percentage and linear flow characteristics. AIR PRESSURE IN ACTUATOR PSI (kpa) ACTUATOR SPRING RANGE (kpa) -7 8 () 9 (6) (69) (6) (8) 4 (97) 6 7 (7) 8 (4) 4- (8) 4 (97) 6 7 (7) 8 (4) 9 () (8) 8-4 (97) 6 7 (7) 8 (4) 9 () (8) C V 46.8 VN / THROUGH IN., DIRECT ACTING, THREADED BODIES WITH IN. DIA. PNEUMATIC ACTUATOR (NORMALLY OPEN) C V 9. 9 () (8) 4 6 8 4 6 (8) (76) (44) () (699) (87) (96) 8 (4) (79)(7) VNXXX VNXXX CLOSE OFF PRESSURE RATINGS PSI (kpa) USE 4- PSI SPRING FOR POSITIONER MODEL (MP9E) C V 8.7 C V.7 TO.9 (9) Fig.. Close-off pressures at various control air pressures for VN Valves and MP9 Pneumatic Actuators. C V.7 C V 7. C V 4.7 M649 6-48

VN TWO-WAY THREADED GLOBE VALVE AIR PRESSURE IN ACTUATOR PSI (kpa) ACTUATOR SPRING RANGE (kpa) -7 7 (48) 8 () 9 (6) (69) (6) (8) 4 (97) 6 7 (7) 8 (4) 9 () (8) 4- (7) (8) 4 (97) 6 7 (7) 8 (4) 9 () (8) 8- (8) 4 (97) 6 7 (7) 8 (4) 9 () (8) VN / THROUGH IN., DIRECT ACTING, THREADED BODIES WITH 8 IN. DIA. PNEUMATIC ACTUATOR (NORMALLY OPEN) C V 46.8 C V.7 TO.9 4 6 8 4 6 (8) (76) (44) () (699) (87) (96) 8 (4) (79)(7) VNXXX VNXXX CLOSE OFF PRESSURE RATINGS PSI (kpa) USE 4- PSI SPRING FOR POSITIONER MODEL (MP9E) M6 (9) Fig.. Close-off pressures at various control air pressures for VN Valves and MP9 Pneumatic Actuators (continued). C V 9. C V 8.7 C V 4.7 C V 7. C V.7 6-48 4

VN TWO-WAY THREADED GLOBE VALVE -7 (-) SPRING RANGE PSI (kpa) 4- (-7) 4 8- (-9) 8 () VN / THROUGH IN. DIRECT ACTING THREADED BODIES WITH 7-/8 REVERSE ACTING PNEUMATIC ACTUATOR (NORMALLY CLOSED) () 7 () AIR PRESSURE IN ACTUATOR PSI (kpa) () 6 (4) () 4 C V.7 TO.9 C V 4.7 C V 7. C V.7 C V 46.8 C V 9. C V 8.7 () (7) (4) () 4 (7) (4) 6 () 7 (48) 8 () 9 (6) (69) (76) CLOSEOFF PRESSURE RATINGS PSI (kpa) USE 8- PSI (-9 KPA) RANGE FOR DETERMINING CLOSEOFF OF VALVES USED WITH MP9F ACTUATORS. (8) (89) 4 (96) 6 () () M6 SPRING RANGE PSI (kpa) AIR PRESSURE IN ACTUATOR PSI (kpa) 4- (-7) 4 () 8- (-8) 8 () 7 () 6 (4) () 4 () () VN / THROUGH -/4 IN. REVERSE ACTING THREADED BODIES WITH IN. DIRECT ACTING PNEUMATIC ACTUATOR (NORMALLY CLOSED) (7) () (4) (7) () Fig.. Close-off pressures at various control air pressures for VN Valves and MP9 Pneumatic Actuators (continued). C V 8.7 (4) 4 (7) 4 CLOSEOFF PRESSURE RATINGS PSI (kpa) (4) C V.7 (8) USE 4- PSI (-7 kpa) RANGE FOR DETERMINING CLOSEOFF OF VALVES USED WITH MP9E ACTUATORS. C V.7 TO.9 C V 7. 6 (4) C V 4.7 6 (4) M6 7 (48) 6-48

VN TWO-WAY THREADED GLOBE VALVE SPRING RANGE PSI (kpa) AIR PRESSURE IN ACTUATOR PSI (kpa) 4- (-7) 4 () 8- (-8) 8 () 7 () 6 (4) () 4 () () VN / THROUGH -/4 IN. REVERSE ACTING THREADED BODIES WITH 8 IN. DIRECT ACTING PNEUMATIC ACTUATOR (NORMALLY CLOSED) (7) () (4) (7) () (4) 4 (7) 4 CLOSEOFF PRESSURE RATINGS PSI (kpa) (4) (8) USE 4- PSI (-7 kpa) RANGE FOR DETERMINING CLOSEOFF OF VALVES USED WITH MP9E ACTUATORS. C V.7 TO.9 6 (4) C V 7. C V.7 C V 8.7 6 (4) M6 7 (48) C V 4.7-7 (-) SPRING RANGE PSI (kpa) 4- (-7) 8- (-9) VN / THROUGH -/4 IN. REVERSE ACTING THREADED BODIES WITH 7 IN. REVERSE ACTING PNEUMATIC ACTUATOR (NORMALLY OPEN) AIR PRESSURE IN ACTUATOR PSI (kpa) 7 () 8 () 9 (6) (7) (7) (8) 4 (9) (7) (8) 4 (9) () 6 7 8 () (8) 4 (9) () 6 7 8 () () (7) () (4) (7) Fig.. Close-off pressures at various control air pressures for VN Valves and MP9 Pneumatic Actuators (continued). () (4) 4 (7) 4 CLOSEOFF PRESSURE RATINGS PSI (kpa) (4) USE 8- PSI (-9 kpa) RANGE FOR DETERMINING CLOSEOFF OF VALVES USED WITH MP9F ACTUATORS. C V 7. (8) C V.7 TO.9 C V 8.7 6 (4) C V 4.7 C V.7 6 (4) M64 7 (48) 6-48 6

VN TWO-WAY THREADED GLOBE VALVE Table. Close-off ratings (psid) for VNxxx and VNxxx Valves with electric/electronic actuators. Mod IV Motor with Q Linkages ML64A,B ML74A,B ML64A,B ML74A,B ML7984, ML6874 Valve Size (NPT) lb 6 lb 8 lb 4 lb lb 6 lb / in. (C v =.7 to.9) a a a a / in. (C v = 4.7) a a a a /4 a a a a 96 9 a 6 96 -/4 a 6 7 a 4 6 -/ 7 8 6 67 8 98 46 9 6 7 46 apressure is limited by fluid temperature. See valve temperature/pressure ratings. Table. Close off ratings (psid) for VNxxx Valves with electric/electronic actuators. Mod IV Motor with Q Linkages ML64A,B ML74A,B ML64A,B ML74A,B ML7984, ML6874 Valve Size (NPT) lb 6 lb 8lb 4 lb lb 6 lb / in. (C v =.7 to.9) a a a a / in. (C v = 4.7) a a a a /4 a a a a a a 9 a a a -/4 a a 7 a a a -/ a 8 6 a 67 8 98 46 9 a 7 46 apressure limited by fluid temperature; see valve temperature/pressure ratings. Maximum Pressure Differential for Quiet Water Service: psi differential. Rangeability: : per VDI/VDE 7. Dimensions: See Fig.. Motor and Linkage Selection: Electric Pneumatic ML64/ML64 MP9 (except " ML74/ML74 ML7984/ML6874 Mod IV w/q Replacement Parts: See Fig. 4. 7 6-48

VN TWO-WAY THREADED GLOBE VALVE Y, Y Y B A VALVE SIZE (IN) / /4 -/4 -/ A -/4 (8) -/4 (8) 4-/6 4-/6 (6) 4-/4 -/4 (4) B -9/6 (9.) -9/6 (9.) -9/6 (9.) -9/6 (9.) -/6 (46.) -/6 (46.) Y Y a STEM DOWN -/ (89) a Y WITH STEM EXTENSION FOR MP9A,C (8 IN. ONLY) Fig.. VN body dimensions in in. (mm). -/4 () M647 6-48 8

VN TWO-WAY THREADED GLOBE VALVE VN DIRECT ACTING TWO-WAY GLOBE VALVES VN REVERSE ACTING TWO-WAY GLOBE VALVES STEM BUTTON ASSEMBLY STEM BUTTON ASSEMBLY PACKING NUT PACKING NUT REPACK KIT REPACK KIT PACKING CARTRIDGE PACKING CARTRIDGE VALVE BODY VALVE BODY B A A AB B SEAT RING PLUG ASSEMBLY PLUG ASSEMBLY SEAT RING BOTTOM NUT LOWER SEAT BOTTOM NUT 9787 REPACK KIT (FOR VALVES WITH /8 INCH STEM) SHOWN. 9786 REPACK KIT (FOR VALVES WITH /4 INCH STEM) CONTAINS THREE PACKING WAFERS INSTEAD OF FOUR. INCLUDED IN REBUILD KIT. Fig. 4. VN replacement parts. M87 9 6-48

VN TWO-WAY THREADED GLOBE VALVE Valve OS No. NPT Size (in.) Flow Capacity (C v ) Stem Diameter (in.) Repack Kit (Part No.) Rebuild Kit (Part No.) Stem Button (Part No.) VN8 /.7 /4 9786 9746A 96 VN6.6 9747A VN4.8 9748A VN.9 9749A VN4 4.7 97A VN7 /4 7. 97A VN6.7 97A VN7 -/4 8.7 97A VN8 -/ 9. /8 9787 974A VN99 46.8 97A VN6 /.7 /4 9786 94A VN4.6 94A VN.8 944A VN.9 94A VN48 4.7 946A VN /4 7. 947A VN6.7 948A VN7 -/4 8.7 949A VN89 -/ 9. /8 9787 94A VN97 46.8 94A VN4 /.9 /4 9786 979A VN 4.7 976A VN /4 7. 976A VN8.7 976A VN46 -/4 8.7 976A INSTALLATION When Installing This Product. Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition.. Check the ratings given in the instructions and on the product to make sure the product is suitable for your application.. Installer must be a trained, experienced service technician. 4. After installation is complete, check out product operation as provided in these instructions. IMPORTANT. Do not lift the valve by holding the stem.. Do not mount the valve with the stem pointed lower than horizontal.. Mount the valve with the flow arrow pointed in the direction of flow through the valve. 4. Mount the valve between aligned pipes. Mounting the valve on pipes that are not aligned causes leakage at the valve-to-pipe connection.. Ensure complete engagement on pipe to valve body threads. 6. Hold the valve body with a clamp or pipe wrench on the hexagonal fitting nearest the pipe to prevent damage to the valve body while mounting on the pipe. Refer to Fig.. 7. Be sure to allow enough room for installation and service. Clearance for valve installation is dependent on actuator size and the valve pipe size. 6-48

VN TWO-WAY THREADED GLOBE VALVE Location Select a location where the valve, linkage (if used), and actuator to be used are within the appropriate ambient pressure and temperature ratings. Leave sufficient clearance above the valve to accommodate actuator installation and allow room for servicing the valve body. (Completely install the valve body in the pipe line before installing the actuator and linkage.) PIPE SIZE (IN.) / /4 -/4 -/ EFFECTIVE LENGTH OF THREADS IN IN. (MM) / (.7) 9/6 (4.) /6 (7.) /6 (7.) /6 (7.) /4 (9.) When selecting a location for the valve, consider actuator mounting restrictions. Modutrol IV Motor chankshafts must be mounted horizontally. Mounting The preferred valve mounting position is with the stem vertical. For steam applications, mount with the stem at a 4 degree angle. Do not mount the valve with the stem more than 9 degrees from the vertical (pointing lower than horizontal). Scale and foreign material can collect, scoring the stem and causing packing leakage. Protect the stem from damage due to bending or scratching. Threading on threaded bodies conform to American Standard Taper Pipe Threads (NPT). Align the pipes squarely with the valve at each end connection. If the pipes are forced into the valve, the body can become twisted and improper seating can result. Apply pipe dope sparingly. Be careful to prevent pipe debris, such as chips and scale, from entering the piping because this material can lodge in the seat and prevent proper closing. Refer to the table in Fig. for valve pipe sizes and thread lengths. Fig. also shows two effective methods of holding the valve and pipe when attaching it. The valve will not function properly if it is twisted or squeezed during installation. Refer to installation information furnished with the linkage and motor when installing these controls. USE PROPERLY REAMED AND CLEANED PIPE AND MODERATE AMOUNT OF DOPE (LEAVE TWO THREADS BARE). USE VISE GRIPS WITH THE HEX END NEXT TO THE PIPE (DO NOT TWIST OR SQUEEZE VALVE BODY). USE VISE TO HOLD PIPE SECURELY TO PREVENT TURNING. USE PARALLEL-JAW WRENCH TO GRIP VALVE HEX FLATS NEXT TO PIPE. M76A Fig.. Installing valves with threaded connections. CHECKOUT Before installing linkage (if used) and actuator, make sure that valve stem operates freely. Impaired stem operation can indicate that the body was twisted or the stem was bent. Either of these conditions may require valve replacement. Check the valve body and connections for leaks. After installing linkage and actuator, check the operation according to the installation information furnished with these controls. Operate the system through one complete cycle to be sure the valve controls properly. Check the valve at regular intervals for leakage around the packing. The packing is spring-loaded and should seldom require attention. If leakage is discovered and inspection shows that the packing gland is screwed down tightly, the repack the valve. 6-48

VN TWO-WAY THREADED GLOBE VALVE Home and Building Control Honeywell Inc. Honeywell Plaza P.O. Box 4 Minneapolis MN 48-4 Honeywell Latin American Region 48 Sawgrass Corporate Parkway Suite Sunrise FL Home and Building Control Honeywell Limited-Honeywell Limitée Gordon Baker Road North York, Ontario MH N7 Honeywell Europe S.A. Avenue du Bourget 4 Brussels Belgium Honeywell Asia Pacific Inc. Room - Sun Hung Kai Centre No. Harbour Road Wanchai Hong Kong Printed in U.S.A. on recycled paper containing at least % 6-48 G.S. 7-98 post-consumer paper fibers. www.honeywell.com