INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Similar documents
INSTALLATION, OPERATION AND MAINTENANCE MANUAL

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Low Pressure Fluid Filters

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

DFA Series. Rainwater/Graywater Filtration Systems. Installation, Operation and Maintenance Manual DFM-2F-180 DFM-3F-180 DFM-3F-350

Manufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1

ECONOMAIR SERIES CYLINDERS

MetroPrime 22MPC Self-Priming Centrifugal Pump

STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications

TITAN FLOW CONTROL, INC.

Dual/Triple Manifold Water Filtration Systems Instruction Manual

3M Housings CH Series

DeZURIK 2 20" BOS BUTTERFLY VALVES

PFS Rotameter. Variable Area Flowmeter. Instruction Manual PFS-RM200, RM230, RM250

Colt Series C400, C500

MODEL 200 MULTI-JET FLOW METER

TITAN FLOW CONTROL, INC.

CLIF MOCK TM. Model 5030 Orifice Fitting. User Manual. Manual No , Rev. B

1 2-Inch Station Outlet Valves

Installation, Operation & Service Manual. PPL Bag Filter Housings. Table of Contents Page No. Eaton Filtration, LLC

MODEL 200 MULTI-JET FLOW METER

Instruction Sheet SRSR SERIES. Rotating Sliding Rail System

L DODGE CUMMINS MK-2 + BLK APPS Mount

Model P-40 & Model P-25 POWER PUSHER

PARTS AND INSTALLATION MANUAL

Dual Flow Manifold Systems Instruction Manual

MODEL 900 IMPELLER-TYPE FLOW METER

Operating and Installation Instructions

Nor East. Instructions Safety Messages. Inspection. Parts. DeZURIK Service. Type 05 Pneumatic Actuator Used With Globe Valves

Spray Nozzle Adapters

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

OWNER S MANUAL Z SERIES TRACKS. Rev. 355_05

OWNER S MANUAL. LOEGERING th Street SE Casselton, ND USA Fax:

Model AS-RC3260 TV Cart. Rolling Cart for Audio Mount System & Flat Panel TVs

Pro Shot Grease Dispense Valve

Series 957, 957N, 957Z, 957RPDA, 957NRPDA, 957ZRPDA

Lubricator Gun: 10,000 psi (700 bar) Maximum Delivery Pressure when disconnected from Dispenser

Installation and Maintenance Manual

Installation Instructions SRC Over-Size Tire Carrier Jeep Wrangler/Unlimited Part # 2743

DODGE CUMMINS 24V ISB OEM BYPASS LIFT PUMP KIT Installation Instructions Part #

Scale Feeder Manifold Water Filtration System Instruction Manual

Model T2642 Wall Mount. Television Wall Mount with Tilt Option

Model FM2642 Wall Mount. Full Motion Television Wall Mount

Nilfisk-CFM SS Vapor Vacuum Instructions for Use and Spare Parts Manual

Air Operated Double Diaphragm Pump. M-Pump ½ Metallic Non Metallic Pump INSTALLATION, OPERATION & MAINTENANCE MANUAL

7.3L Ford PowerStroke

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE

THD-2-FM CONTROLAIR VALVE

DODGE CUMMINS Arctic-Heat Grid Relocation Kit

Tiller Lock Assembly

Air Control Kit INSTRUCTIONS-PARTS LIST. Table of Contents HIGH VOLUME. 250 psi (1.7 MPa, 17.2 bar) Maximum Air Inlet Pressure

GRINNELL Model B302 and Model BN302 Grooved End Butterfly Valves with Gear Operators or Lever-Lock Operators General Description

DODGE CUMMINS Air-Boss CR Intake Plenum

Table of Contents. Page 2. midlandusa.com. Model PPG100

Installation Instructions Receiver Rack (Part # 7700) Universal Application

PCC O P E R A T I O N S. Pump Cycle Counter M A N U A L. Environmental Systems

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

Models P420A-3100 & P420A-5100

WJ-Series. Turbine Meter Instructions ISO. 6 Meter. 3 Meter. Precision Flow Measurement. An ONICON Brand 9001:2008. if ie

HV Gate Valve with pneumatic actuator

Air-Boss VP Intake Plenum

Model AS-FM64 Wall Mount. Full Motion Television Wall Mount

USER MANUAL. NEMA 48C Flange Mounted, Enclosed, Clutch Brake. FMCBE Model 500 FORM NO. L A (i)

INSTALLATION MANUAL #29 FOR CHEVY DIESEL PICKUP TRUCKS. MODEL RP-100 & RP-150 With New Quick Connect Components

A Member of the. Integrated Metering Technologies

Doc No. : I , Satyam Ind. Estate, Subhash Road,

INSTALLATION MANUAL DURAMAX DIESEL POWERED PICKUP TRUCKS MODEL RP-100 & RP-150. With New Quick Connect Components!

Installation Instructions

LBH / LBFR SERIES. Instruction Sheet. Telescoping Lacer Bar

INSTALL GUIDE Dodge/RAM 5.7L HEMI

PNEUMATIC PIPING DEVICES Service Information

Air Curtain. Installation, Operating and Maintenance Instructions

Instruction Sheet DWRSR-ZL. Zero Clearance Latch

Service Guide JATCO Environmental Protection Tank Model J-7000

FOR TECHNICAL ASSISTANCE

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type

ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase

Model GXR Series. Consumer Pump. Triplex Plunger Pump Operating Instructions/ Repair Instructions Manual

Installation Manual DIAPHRAGM WELL TANK

Microscope light manual

Model Series. PumpAgents.com - buy pumps and parts online ELECTRIC BILGE PUMPS. Model Series FEATURES SPECIFICATIONS STANDARD MODELS

MODEL G300 Brake Bleeder

½ DODGE CUMMINS OEM BYPASS LIFT PUMP KIT Installation Instructions Part #

APCO ACS-1200/1700 COMBINATION SLOW CLOSING AIR/VACUUM VALVE

OWNER S MANUAL. Model: PLATINUM55 ( ) (55 Gallon Deluxe Lawn & Garden Spot Sprayer)

DeZURIK 24 and Larger BHP High Performance Butterfly Valves WITH (FB) FYRE-BLOCK SEAT

DODGE CUMMINS MK-2 Micro-Kleen System

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

Instruction Sheet. SFR Series. Swing Frame rack

TABLE OF CONTENTS. Important Safety Information 3. Parts List 4

Owner s Manual. Soda Ash ph Neutralizer System

DODGE CUMMINS GDP Big Line Kit

TMCo,, Inc. The Measurement Company

Pneumatic Cylinder 14 Bore X 21 Stroke Part No. P Replaces Part No. P

3 Station Bike Rack Organization Center

SUPPLEMENTAL MANUAL FOR THE INSTALLATION, OPERATION AND MAINTENANCE OF THE XL234 FILTER VESSEL

Transmission Guardian

Transcription:

PAGE: 1 of 6 INSTALLATION, OPERATION AND MAINTENANCE MANUAL ROSEDALE PRODUCTS, INC. MODEL 4 200 PSIG RATED FILTER UNIT Table of Contents I. INSTALLATION................................................................. 2 II. OPERATION..................................................................... 3 III. SPARE PARTS LIST.............................................................. 4 IV. SPARE PARTS DIAGRAM......................................................... 5 Rosedale Engineering Standards are the property of A Rosedale standard or copy thereof shall not be distributed (except with express approval of Rosedale

PAGE: 2 of 6 I. INSTALLATION Please remove all shipping and crating materials carefully. Be sure to remove the plugs from the inlet and outlet openings. Dispose of all crating materials safely. The Model 4 Filter unit is capable of having several different piping variations based upon the outlet style of your unit. The inlet service line should be connected to the inlet flange or NPT coupling located near the top of the unit (above basket level). The outlet service line should be connected to the outlet flange or coupling, located near the middle or bottom of the unit depending upon the style of your unit (below basket level). There are two 1/4" NPT ports on the shell and one 1/4" NPT port on the cover of your Model 4 Filter (Note: The Model 4-6 has only one 1/4" NPT port, located in the cover.) These ports can remain plugged or used for pressure gauges, vents, or special fitting as your application requires. Some installations require electrical grounding of all equipment, be sure to provide adequate grounding where necessary. After completing installation be sure to double check connections for integrity. Your Model 4 Filter unit has been factory pressure tested leak free, therefore, any seepage problems usually occur from improper installation connections. You are now ready to install the filter basket and bag (if applicable). Remove cover by loosening the T-bolt clamp sufficiently to allow removal of the clamp assembly, lift cover to remove. The next step is to install the strainer or filter bag basket. When a strainer basket is utilized it is recommended that an o-ring be installed under the rim of the strainer basket to prevent by-pass of unfiltered fluid (specify basket seal on order). If your installation requires a filter bag, place bag into the bag basket and insert bag and basket into the housing making sure the filter bag ring is firmly seated on the I.D. of the housing. This configuration does not require a basket seal, the bag ring serves as the seal. Before replacing cover assembly, inspect cover seal gasket (replacing as necessary). Replace cover and securely tighten T-bolt clamp closure to ensure a leak proof seal between cover and housing body. Your Rosedale Model 4 Filter is now ready for operation! Rosedale Engineering Standards are the property of A Rosedale standard or copy thereof shall not be distributed (except with express approval of Rosedale

PAGE: 3 of 6 II. OPERATION Filter System Start-Up Procedure: Prior to turning on the flow to the inlet service, please make the following checks: 1. Check inside filter unit to be sure basket and filter bag (if applicable) are in housing and do not require cleaning or replacement. If necessary install clean filter basket and bag (if applicable). 2. Check that filter cover is securely fastened to housing. You are now ready to open the flow to the inlet service line. Slowly open the inlet service line to approximately 25% of normal operational flow (open slowly as not to displace filter bag inside the housing). After filter unit is pressurized and vented, slowly open outlet service line unit valve until completely open. Complete opening of inlet service line until desired flow rate is reached. Once the desired service flow has been established, the filter will operate efficiently until dirty. However, under no circumstances should more than 15 PSI Differential Pressure through the filter be obtained. Operating the filter unit with a high differential may cause filter bags to rupture and/or cause damage to filter system and downstream equipment. To prevent excessive drop through the filter unit, regular inspection of the filter media is required. Monitoring of differential pressure through the housing can be utilized as a means of determining whether or not the filter media needs cleaning or replacement. When it becomes necessary to clean or replace filter media, follow the procedure outlined below: 1. First close the flow from the inlet service line. 2. Close the flow to the outlet service line. (In some applications closing flow to outlet is not required.) 3. Relieve the pressure in the filter unit. WARNING CONTENTS UNDER PRESSURE Relieve Pressure in accordance with Manufacturer's instructions before opening Filter Vessel. FAILURE TO DO SO MAY RESULT IN SERIOUS BODILY INJURY. 4. Drain housing sufficiently to access filter basket. 5. Remove cover by loosening the T-bolt clamp sufficiently to allow removal of the clamp assembly, lift cover to remove. 6. Remove filter basket and clean thoroughly, remove the filter bag (if applicable) and throw away. (Cleaning and reusing the filter bag is not recommended.) 7. Remove debris and sludge from inside the inlet portion of housing to avoid interference with cover seal or flow of fluid being filtered. Rosedale Engineering Standards are the property of A Rosedale standard or copy thereof shall not be distributed (except with express approval of Rosedale

PAGE: 4 of 6 8. Install clean filter basket and filter bag (if applicable). Be sure filter bag is properly seated inside the housing. 9. Inspect cover gasket for cuts or other signs of failure, replace if necessary, and make sure it is properly seated. 10. Reposition cover onto housing, install T-bolt clamp and securely tighten to ensure a leak proof seal between the cover & housing body. Your Rosedale Model 4 Filter unit is now ready for operation. Refer to filter system start-up procedure. III. SPARE PARTS LIST Your Rosedale Model 4 Filter unit will give many years of reliable service provided periodic inspections are made of various components and replacement of worn parts are made promptly. The following is meant to be a recommended spare parts list, these parts are illustrated on the following page. SPARE PARTS LIST Balloon Description Part Number Time-Frame 1 Cover Seal 4200CG-* as needed 2 Basket Seal 4BG-* as needed 3 Cover 4C200-* as needed 4 Cover Clamp 4CC200 as needed 5 T-Bolt 4T-BOLT as needed 6 T-Handle 4T-HANDLE as needed 7 Filter Bag (See Order) as needed 8 Filter Basket (See Order) as needed * Select Material Designation: C=Carbon Steel B=Buna N S=304 Stainless Steel E=Ethylene Propylene S316=316 Stainless Steel V=Viton HC22=Hastelloy C-22 TEV=Teflon Encapsulated Viton TSW=Teflon Solid White Rosedale Engineering Standards are the property of A Rosedale standard or copy thereof shall not be distributed (except with express approval of Rosedale

PAGE: 5 of 6 IV. SPARE PARTS DIAGRAM Rosedale Engineering Standards are the property of A Rosedale standard or copy thereof shall not be distributed (except with express approval of Rosedale

PAGE: 6 of 6 Important Notice Warranty: In the event any filtration product is found to be defective in material, workmanship, or not in conformance with any express warranty for a specific purpose, Rosedale's only obligation and your exclusive remedy, shall be to repair, replace or refund the purchase price of such parts or products upon timely notification thereof and substantiation that the product has been stored, maintained and used in accordance with Rosedale's written instructions. EXCLUSIONS TO WARRANTY: THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR OTHER WARRANTY OF QUALITY, EXCEPT OF TITLE AND AGAINST PATENT INFRINGEMENT. LIMITATION OF LIABILITY: Except as provided above, Rosedale shall not be liable or responsible for any loss or damage, whether direct, indirect, incidental, special or consequential, arising out of sale, use or misuse of Rosedale filtration products, or the user's inability to use such products. THE REMEDIES SET FORTH HEREIN ARE EXCLUSIVE. 3730 West Liberty Road USA 734-665-8201 800-821-5373 Fax. 734-665-2214 filters@rosedaleproducts.com http://www.rosedaleproducts.com Rosedale Engineering Standards are the property of A Rosedale standard or copy thereof shall not be distributed (except with express approval of Rosedale