Operator Manual For use with WFCO ULTRA III Deckmount Converter WF-9800 Series (model number located on the cover of the unit)

Similar documents
Operator Manual For use with WFCO ULTRA III Distribution Center WF-8900 Series (model number located on the door assembly label)

Operator Manual For use with WFCO ULTRA III Power Center WF-9900 Series (model number located on the door assembly label)

Operator Manual For use with WFCO ULTRA III Power Center Model WF-8712P and WF-8725P

WF-5110R True Sine Wave Inverter

WF-5100 Series True Sine Wave Inverters

WF-5110R True Sine Wave Inverter

WF-9500 Series Power Centers

WF-8500 Series Power Centers

1000 Watt Pure Sine Wave Power Inverter, Users Manual

Installation and Operation Guide for PD4100 Series Power Control Centers

IV. PROOF OF PURCHASE: A warranty claim must be accompanied by proof of the date of purchase.

WARNINGS, CAUTIONS AND NOTES

MODEL 2602A-12 3 STAGE AUTOMATIC BATTERY CHARGER OWNER S MANUAL SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS

Cruising Charger Series OWNER S MANUAL

Installation and Operation Guide for PD5200 and PD5300 Automatic Transfer Switch

GP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax:

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

Smart Battery Charger GPC-35-MAX GPC-45-MAX GPC-55-MAX GPC-75-MAX GPC-100-MAX. Owner s Manual

Go Power! Manual. GP-1750HD Inverter GP-2500 Inverter

VP-6124/VP-6124-E 24 VOLT DC SWITCHING POWER SUPPLY

10 AMP ON BOARD BATTERY CHARGER

Installation and Operation Guide for PD5100 Automatic Transfer Switch

Go Power! Manual. GP-Smart Charger

Power InverterTM Watt. Continuous. User's Manual. WAGAN Corp. Limited Warranty Registration Form. Item no

CLEAN POWER TM CPS Series Operator s Manual

Intelligent Charging System Series

ELECTRONIC MARINE CONVERTER/CHARGER Owners Manual Models PD2020, PD2030, PD2040, PD2050, PD2060, PD2080

Notice of Copyright XPower Pocket Inverter 100 Owner s Guide September 2006 Xantrex International. All rights reserved.

Operating Instructions for Your Cobra 300 Watt POWER INVERTER M ODEL CPI 300. Nothing comes close to a Cobra

S150,S300 Series Pure Sine Wave Inverter User s Manual

DX100. Owner's Guide Conforms to UL Std Toll Free

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

BRAVO Inverter/Battery Charger. Table of Contents

6300 Series Owner/Operator Manual

EN120 EN180. Owner's Guide Conforms to / Conforme à UL std. 458, Toll Free

Power Inverter. Owner s Manual

DC-AC Power Inverter SAM Manual. Please read this manual before installing your inverter

User Guide IGD Series

INSTRUCTIONS FOR OUTDOOR WALL LANTERN, MODEL LPT-1107

HE1U 1248 BMS High Efficiency 1U AC to DC Power Supply Owners Guide SPECIFICATIONS

Toll Free DX100. Owner's Guide. Printed in China

The Power of Reliability INSTRUCTION MANUAL

RU BMS Power Supply and Battery Management System Owners Guide

MQ4C-24/6485 WIRELESS INDOOR/OUTDOOR QUAD-COPTER

WARNING: CAUTION: Notice : XR175 Owner's Guide

BroadBand PowerShield. 20 AHr Battery. User Manual

Nature Power Inverters. Modified Sinewave 1000w/1500w True Sinewave 1000w/2000w. Owner s Manual

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

ADI-125/750 ADI-125/1500 ADI-125/2500

Use and Care Guide.

4 AMP WATERPROOF BATTERY CHARGER/MAINTAINER INSTRUCTION MANUAL

600 Amp Battery Jumper with Air Compressor

Power Inverter 400 MW Owner s Manual

30 Amp Solar Charge Controller

OWNERS MANUAL JANUARY 2007 ISO

DC to AC Power Inverters

DC to AC Power Inverters

230VAC Power Inverter 400W Owner s Manual

1200+ WITH LVD (LOW VOLTAGE DISCONNECT) USER GUIDE

INSTRUCTION MANUAL. 12-Station HD Shop 12V Portable Battery Charger

24 VOLT AUTOMATIC BATTERY CHARGER PART NO

Installation & Operators Manual

Digital Power Inverter

8 Step Fully Automatic Intelligent BATTERY CHARGER 12V 5A USER S MANUAL. Charges & Maintains. Flooded (WET), MF, VRLA, AGM, GEL & Calcium batteries

V 2.0 DC TO AC POWER INVERTER PWRINV500012W PWRINV500024W PWRINV500036W PWRINV500048W. Instruction Manual

800 WATT POWER INVERTER

2603 Battery Pal 3 AMP, 1 2 VOLT BATTERY CHARGER

Table of Contents. Introduction. How Your Cobra Power Inverter Works. Rechargeable Appliances 1. Quick Checkout 2-3. Operation 4

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

Table of Contents. Introduction. How Your Cobra Power Inverter Works. Rechargeable Appliances 1. Quick Checkout 2-3. Operation 4

SPC Series. Digital Scale. Operation Manual

XPower Inverter 175 Plus, 400 Plus, 700 Plus. Owner s Manual

Item no Smart AC 200 USB. User s Manual

800 WATT POWER INVERTER

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

installation kit Ask your retailer!

INSTALLATION & OPERATION MANUAL

800 WATT POWER INVERTER

Please read and understand all precautions prior to use.

Compact Scales. Software Revision V1.25 & above

RJH-4/6046. Wireless 3.5 Channel Mega Helicopter. (Instruction Manual)

OPERATING INSTRUCTIONS

QSSE, QSSEX INDUSTRIAL Battery Chargers

GSL Electronics Modified Sine Wave Power Inverters

CAUTION: Read manual carefully for proper procedures and operation.

MIL-24/2600Q MIL-24/3200DQ

Wireless Key Tracker. Locate Lost Keys instantly

This document describes:

Sylvania 9 Color Changing One Plug Tree Tree ID # T5, Item # V

Owner s Manual & Safety Instructions

LESTRONIC II BATTERY CHARGER TAYLOR-DUNN MODEL TYPE 24LC25-8ET

Operating Instructions for Your Cobra 150 Watt POWER INVERTER M ODEL CPI 150 FAULT OFF. Nothing comes close to a Cobra

Table of Contents 文管中心 發行章

LESTRONIC II BATTERY CHARGER BUILT-IN OR PORTABLE CHARGERS

Solar Charge Controller Owner s Manual SC 1210 SC 1210LD SC 1220LD

CAPACITOR ACTUATED PORTABLE STARTER CAPS USER GUIDE. INST048 Doc 3.01

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

AC / 65 W M PLEASE READ BEFORE OPERATING THIS EQUIPMENT.

1200+ WITH LVD (LOW VOLTAGE DISCONNECT) V1.00 OWNERS MANUAL

Transcription:

Operator Manual For use with WFCO ULTRA III Deckmount Converter WF-9800 Series (model number located on the cover of the unit) Distributed in the U.S.A. and Canada by ARTERRA DISTRIBUTION Warranty Service (877) 294-8997 Fax (574) 294-8698 www.wfcoelectronics.com

Installation and Servicing of the WFCO WF-9800 Series Power Center This product should be installed by an experienced technician. CAUTION and care must be taken when servicing this equipment. To prevent severe shock or electrocution consult your servicing dealer. No serviceable parts.! WARNING! This unit employs components that tend to produce arcs or sparks. To prevent fire or explosion, do not install in compartments containing batteries or flammable materials (LP gas). To prevent fire, do not cover or obstruct ventilation openings. Do not mount in zero-clearance compartment. Overheating may result. For continued protection against risk of fire, or electric shock replace only with same type and ratings of fuse. Check on a monthly basis the fluid level in any battery connected to RV charging system. This product is not ignition protected and should not be installed in an LP compartment. INSTALLATION INSTRUCTIONS General Consumer Information Reverse Battery Protection This feature prevents permanent damage to the converter from an incorrect battery connection. Automatic Cooling Fan The fan is variable speed and current controlled. Electronic Current Limiting Automatically shuts down power during overload or short-circuit conditions. Automatically returns to normal operation after conditions are corrected. DC Fuses Reverse battery protection fuses; replace with ATC Littelfuse Type 257 fuse. Lightweight - 35 A unit weighs only 9.03 lbs. - 45 A unit weighs only 11.20 lbs. - 55 A unit weighs only 11.57 lbs. - 65 A unit weighs only 14.33 lbs. - 75 A unit weighs only 14.88 lbs. 3 CHASSIS (EARTH) GROUND Distribution Panel/ Power Center WF-8930/50NP GROUND BAR 12 V BATTERY

MODEL: WF-98XX Converter Operation Modes Troubleshooting WF-9800 Series Converter All WFCO power converters are automatic three-stage switching power supplies. The converter senses which mode it needs to be in by checking the RV system voltage. The three modes/stages of operation include: Absorption mode/normal operation Nominal battery charge and supplies power to appliances Bulk mode/charge mode Fast battery charge and supplies power to appliances Float mode/trickle charge Trickle battery charge during storage Absorption Mode: During this mode, the converter output is in the 13.6 Vdc range. This is the normal operation mode. This mode provides the 12 Vdc and current required by the 12 Vdc RV appliances, as well as slow charging the battery. Bulk Mode: In this mode, the output voltage of the converter will switch to 14.4 Vdc for a maximum of four hours. If the converter cycles between Absorption and Bulk mode, there could be a shorted battery cell or other issues. Float Mode: In this mode, the converter is charging the battery with a trickle voltage of 13.2 Vdc. When the converter senses a demand (by turning on lights), the converter automatically returns to the Absorption mode. OPERATIONAL FEATURES TROUBLESHOOTING INSTRUCTIONS If the input from shore power is 105 Vac-130 Vac to the receptacle, check the reverse battery protection fuse on the front plate of the WF-9800 deckmount converter. Visually inspect the fuses for any breaks/opens. If the fuses do not appear to be open, use a tester to check for continuity. SHORE POWER AC OUTPUT (30 A OR 50 A) RECEPTACLE AC OUTPUT (Power Center) AC INPUT MODEL LABEL SERIAL LABEL DC OUTPUT Reverse Battery Protection Fuses If the reverse polarity fuses are blown, it means the RV battery was accidentally connected in reverse, either at the battery or at the converter. Reconnect properly, then replace the fuse with the same type and amp rating as the original Littelfuse Type 257 automotivestyle fuse. IMPORTANT: These fuses protect the converter from damage in the event that the RV battery is accidentally connected in reverse. A reverse battery connection, even for a second, is the only reason that these fuses will blow. 6 7 FUSE FUSE POS+ NEG - ATC Style Littelfuse Type 257 fuse RED BLACK Ground

WF-9800 Series Troubleshooting GENERAL COMPLIANCE INFORMATION Before checking the converter output voltage, it is necessary to disconnect the battery cables at the battery. Make sure the converter is plugged into AC source (105-132 Volts). Check the converter output voltage at the battery with a voltmeter. Place the probes on the disconnected battery cables; place the Positive (red) meter probe on the + positive red battery wire and place the Negative (black) meter probe on the -Negative black wire on the battery cable. Be sure you have good connections at the cables. If the voltage reads 13.6 Vdc (+/-.2) with no load, the converter is functioning properly. CHASSIS (EARTH) GROUND Nominal setup for WF-9800 Series REVERSE BATTERY PROTECTION FUSES FOR TESTING PURPOSES DISCONNECT THESE OUTPUT WIRES GROUND BAR Distribution Panel/ Power Center WF-8930/50NP 12 V BATTERY If the converter output voltage at the battery reads in the 0.0 Vdc range, or the battery is not charging, check for: - an open inline fuse in the battery wire (if installed by OEM) - an open wire between the converter and the RV battery - loose ground connection - improper torques If the converter fuses and AC voltage are good, but the converter output still reads zero volts, the converter is not functioning properly. Contact WFCO Tech Support at (877) 294-8997. 0V DC 20V TROUBLESHOOTING INSTRUCTIONS 8 COMPLIANCE 9 The WF-9800 Series units are UL-Listed, and cul-listed (Canadian). They comply with FCC Class B requirement (see below) FCC Compliance Class B NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Consumer Limited Warranty For WFCO Electronic Products WFCO extends to the original owner a Two-Year Limited Product Warranty. This Warranty is in effect from the date of original purchase for a period of two (2) years. This Limited Warranty is extended specifically for and is limited to recreational vehicle application and is valid only within the continental United States, Alaska, Hawaii and the provinces of Canada. WFCO warrants to the owner that its products are free from defects in material and workmanship under normal use and service, based on its intended use and function. This Warranty is limited to the repair or replacement, at WFCO' s discretion, of any defective parts or defective assembly. Any implied warranties of merchantability or fitness for intended use are limited in duration unless applicable State Law provides otherwise. You may have other rights as specified by each individual state. EXCLUSIONS and LIMITATIONS The OEM Warranty specifically does not apply to the following: Any WFCO product that has been repaired or altered by any unauthorized person. Any damage caused by misuse, faulty installation, testing, negligence or accident or any WFCO product installed in a commercial vehicle. Any WFCO product whose serial number has been defaced, altered or removed. Any WFCO product whose installation has not been in accordance with the WFCO written instruction. Any consequential damages arising from the loss of use of the product including, but not limited to, inconvenience, loss of service, loss of revenue, loss or damage to personal property and cost of all services performed in removing or replacing the WFCO product. Specifications are subject to change without notice or obligation. LIMITED WARRANTY CONSUMER WARRANTY CLAIM PROCEDURE Upon determination and validation by an authorized OEM dealer that a WFCO product has a defect, a Return Goods Authorization (RGA) number will be required before it can be returned. The RGA number can be requested by completing the Warranty Information Fax Sheet found at www.wfcoelectronics.com. Once the form has been completed, email this form along with Proof of Purchase to warranty@wfcoelectronics.com or fax both forms to the Warranty Department at (574) 294-8698. After receipt of the forms, an RGA number will be issued. This number shall appear on all correspondence with warranty service. Upon validation of the warranty, WFCO shall replace or repair the product with a like product. The RGA number shall be placed on the outside of the carton used to return the product, for ease of identification. Do not mark directly on the product. The product must be packaged properly to avoid further damage to the product, which could cause a non-warrantable condition. 10 CD-M-00003-7