XW Series E-Stops. Safety. ø22mm XW E-Stops Phone: Fax: Web: -

Similar documents
XW Series E-Stops. Safety. Selection Guide ø22mm XW E-Stops

22mm XW E-Stops. IEC , EN , JIS C , UL508, UL991, NFPA79, CSA C22.2 No. 14, GB

22mm XW E-Stops. UL File #E68961 CCC No Specifications

Switches & Pilot Devices

XW Series Emergency Stop Switches

XA Series Emergency Stop Switches (w/removable Contact Block)

Emergency Stop Switches

Emergency Stop Switches Selection Guide

ø22mm XW Series Emergency Stop Switches (Mechanical Indicator) Smooth Button Delivers Style and Cleanliness

ø22mm HW Series Control Units Control Units

ø22mm HW Series Control Units

MW Series Control Units

Standard Interlock Safety Switches

NO NO NO. Standard Interlock Safety Switches HS6B. HS5E-K Key Locking Safety Interlock Switches

Oiltight Switches & Pilot Devices

HS5D Miniature Interlock Switches

ø30mm Series Switches & Pilot Lights

Oiltight Switches & Pilot Devices

Style Contact Type No. Button Color Code ø40mm Mushroom 1NC YW1B-V4E01R YW1B-V4E21R. Gasket ø40 YW1L-V4E11Q0R 2NC YW1L-V4E02Q➂R 6 (12V AC/DC)

Solenoid Locking Safety Switches

HS5D Miniature Interlock Switches

Switches & Pilot Devices

Solenoid Locking Safety Switches

IDEC E-Stop Switches. Simply Safe. Smart Products. Simple Solutions.

HS1L Interlock Switches with Solenoid

Interlock Switches. Safety. Selection Guide HS6B Subminiature HS5D Miniature HS2B Full Size...

Door Interlock Switches

HS1C Interlock Switches with Solenoid

HS2B N B - R. Door Interlock Switches. HS2B Series. Full Size Interlock Switch. Part Number. HS2B features: Part Number Key.

Safety Control HR1S-AC. Safety Relay HR1S-AC

panasonic.net/id/pidsx/global Solve issues related to machine safety and other safety measures with a safety door switch with key!

SG-B1 SERIES / SG-A1 SERIES

Door Interlock Switches

HS1B R - R. Door Interlock Switches. HS1B Series. HS1B Series Full Size Interlock Switch. Part Number. HS1B features: Part Number Key.

Miniature Switches & Pilot Devices

Safety device new products line up. Introducing a safety door switch with solenoid interlock that is among the world s thinnest*

ø16mm X6 Series Emergency Stop Switches Excellent safety and design. The shortest depth behind the panel in its class.

HS5E Miniature Interlock Switches with Solenoid

HS1E-K Interlock Switches with Solenoid (3-circuit)

Safety Products. Safety Products. HS5E Series. HS5E Series Miniature Solenoid Locking Switch

Door Interlock Switches

Standard Interlock Safety Switches

HS1E Series Full Size Solenoid Locking Switches

HS1B Series Full Size Interlock Switch. GS-ET-15 BG standard in Germany. Part Number Key

Miniature Switches & Pilot Devices

HS1E Series Full Size Interlock Switch with Locking Solenoid

HS5E Series Miniature Solenoid Locking Switches

Head Removal Detection Function for Safer Performance

HS1L Interlock Switches with Solenoid

L1 = Solder terminal 2.8 x 0.5 mm Ø Behind panel

Oiltight Switches & Pilot Devices

LW Series offer flexibility in space-saving package

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

HS6B HS6E. Angled connection. cable. Compact with three poles of contacts. (HS6B) Small interlock switch with five poles and solenoid.

Door Interlock Switches

HS1L Interlock Switches with Solenoid

FS1A Safety Controller

A series Switches & Pilot Lights

Enabling Switches. Safety. Selection Guide

HS1C Series Full Size Interlock Switch with Locking Solenoid. GS-ET-15 BG standard in Germany. HS1C Series Functionality

HS6E Subminiture Interlock Switches with Solenoid

HS6B Series Subminiature Interlock Switch

30mm Hazardous Location Switches:

ø25mm TWS Series Control Units

EXCEL CELL ELECTRONIC CO., LTD. NO. A S P E C I F I C A T I O N Edition 2 Page 1

HS1E Interlock Swithes with Solenoid

Switches & Pilot Devices

HW Series 22mm IEC Style Global Pushbuttons

Section. Safety Products Selection Guide...B-2

HS6E - L 4 4 B 01 - G

[ Bezel size ] [ From panel front ] [ Shape ] [ Contact rating ] [ Action ] Unibody

30mm Hazardous Location Switches:

Relays & Sockets. RQ Series PCB Relays

Switches & Pilot Devices

D4SL. Safety Interlock Switches. Compact 6-Contact Guard Lock Safety-Door Switch NEW! Specifications. Standards and EC Directives

Oiltight Switches & Pilot Devices

LW Silhouette Series. Illuminated Key Selector Switches Pushbuttons and Illuminated Pushbuttons with Round Guard. LW Silhouette Switches

Safety Limit Switch

Door Handle Gate System

NRBM Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

ø8 A8 Series Miniature Control Units

HS1C-P Interlock Plug Unit with Door Lock

HS6E Subminiature Interlock Switches with Solenoid. Double Installation. Part Number. Cable Length (+) ( ) A2 A1

ø22mm LW Series Control Units

Door Interlock Switches

Operator Interface 4-1. General. Safety Switches. 4-Table of. Contents. Logic. Power. Operator Interface Table of Contents. 2-Opto-electronics

HS6B Series Sub-Miniature Interlock Switch. Direct Opening

Non-illuminated Push Buttons

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

A Series. Miniature Control Units

Enabling Switches Grip Style Enabling Switches

Illuminated buzzer for elevators, robots and production sites

LK Position Switches TECHNICAL DATASHEET.

Miniature microswitches - Positive break

ø12 A2 Series Miniature Control Units

HS5E Miniature Interlock Switches with Solenoid

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

Transcription:

Safety ø22mm XW E-Stops... 277 XW Series E-Stops Overview Interlock Switches Enabling Switches Safety Control ight Curtains AS-Interface Safety at Work Phone: 8.894.412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

X Series E-Stops X Series E-Stops evolutionary Safe Break Action Design Overview The IDEC Emergency Stop switches, the X6, XA, XW, and XN series, include revolutionary new technology that have changed the way E-Stop switches are designed. This safe break action concept provides greater levels of human safety and is the first of its kind in the world! Innovative Design AS-Interface Safety at Work ight Curtains Safety Control Enabling Switches Interlock Switches Conventional E-Stop switches are designed with spring pressure on the Normally Closed (NC) contacts, keeping them in the closed position and allowing the machine to operate. Improper installation or excessive force to the stop button in an emergency may break or dislodge a vital part, causing the spring loaded contact to stay closed. This situation renders the E-Stop incapable of stopping the machine, and can lead to catastrophic events, personal injury and possible loss of life. Safe Break Action Design evel 4 Safety Operator Contact Block This one-of-a-kind safe break action design, found only in the IDEC XA, XW, and XN series, reverses the energy direction and uses the spring-pressure to assure that the NC contacts will open if the emergency switch is damaged or the contact blocks separate due to excessive force. The NC contacts will reliably open, even if they are welded, and stop the machine. Combined with IDEC quality, this is the E-Stop switch you want in a life threatening situation. X6, XA, XW & XN Series, The Safe Break Action E-Stops! NC Contact Closed (On) each for the Safe Break Action Internal view while removing the contact block 1 2 3 NC Contact Open (Off) When the contact block is removed from the operator the main contact (NC) is forced to open (OFF). When removing the contact block, the cam provides a direct opening action to open the contact. Padlock E-Stops As shown in the diagram, upon latching a traditional E-stop, it is up to the technician to verify and confirm that the machine area is clear and there are no other technicians working before resetting the E-stop and turning on the machine. There is always a chance that the technician might miss someone in the work area before resetting the E-stop, potentially causing injury to that person. The solution is XN4E series padlock E-Stops, which allow technicians to install their personal padlocks at the spot of actuation of the E-Stop ensuring their own safety. The diagram shows how personal padlocks can be installed. Each one blocks the resetting of the E-stop until all the padlocks are removed. This provides added safety and prevents unauthorized or accidental resetting of the E-stops. A maximum of 2 padlocks can be installed by using lockout hasps. Press the button. The X Series of E-Stop switches include up to four contacts in a very compact package. In today s automated world, more customers are requiring E-Stop switches with at least three contacts. (Two of the contacts trip the power and the third contact is used to alert a safetymonitoring relay.) Both the XA and XW series switches offer up to four safe-break contacts with a depth behind the panel that is half the size of conventional E-Stop switches. This means that there is an additional contact available and the switches can be used in evel 4 safety category applications. IDEC s new E-Stop switches are secured from the rear of the control panel so that the E-Stop cannot be removed from the front. Another unique feature of the XA & XW E-Stop switches is that either a push-turn or push-pull reset method can be used to reset the switches. This eliminates any possible confusion for operators when resetting the switch. The durability and quality of these new E-Stop switches make them extremely reliable. They can withstand the increased high stress caused by panic or a reaction to an emergency situation. Button atched When using as a general emergency stop switch When preventing unauthorized resetting Install the padlock. Hasp can be used. Safety Confirmed Turn the button to reset. emove the padlock. Operation allowed Phone: 8.894.412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

X Series E-Stops X Series E-Stops everse Energy Structure With X Series E-Stops, the potential energy level of the latched status is lower than that of the normal status. When the switch is damaged due to excessive shocks, the NC contacts will turn off, thus stopping the machine (patented design). Direct Opening Action Even if the contacts are welded, the force applied on the button directly opens the contact. ated Insulation Voltage: 25V ated Thermal Current: 2.5A Safety Interlock Mechanism Contacts are opened when the operator is locked, and remain opened until the operator is unlocked intentionally. (IEC6947-5; 6:2) Pushlock Pull or Turn eset The X Series E-Stops can be reset either by pulling or turning the button. This ensures that the reset action will always be different from the make action. With traditional E-Stops, you need to choose between Push-Pull or Pushlock Turn eset. With the IDEC X Series E-Stops you get both in one switch. XN4E, padlock type is Turn eset only. Compact Body with Four Contacts 48.7mm 27.9mm Important Safety Information Traditional E-Stop High ymain contacts (NC) Main contacts (NC) are always inclined are always inclined to turn on (danger). to turn off (safe). Operator Stroke Operator Stroke Normal atched Normal atched nergowe2nd Generation (Conventional) (NC): ON (machine can operate) contacts nergymain owe3rd Generation (everse Energy Structure) Main contacts (NC): ON (machine can operate) Two E-Stops in One Compact Pull eset Main contacts (NC): OFF (machine cannot operate) 22mm XW and 16mm XA Series ~2mm High Main contacts (NC): ON (machine can operate) Main contacts (NC): OFF (machine cannot operate) Turn eset XN Series 47.7 mm Main contacts (NC): OFF (machine cannot operate) Overview Interlock Switches Enabling Switches Safety Control ight Curtains AS-Interface Safety at Work Phone: 8.894.412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Selection Guide X Series E-Stops Selection Guide Overview Series X6 XA XW XN Appearance Interlock Switches Enabling Switches Page see Switches & Pilot Devices section see Switches & Pilot Devices section 277 see Switches & Pilot Devices section Mounting Hole 16mm 16mm 22mm 3mm Operator Type eset Action E-Stops: Pushlock Pull/Turn eset Illuminated & E-Stops: Pushlock/Turn eset, Push-Pull Pushlock Pull or Turn eset (both actions available in each switch, except XN4E) Contact Configuration 1NC, 2NC 1NO - 1NC, 2NC, 1NO-3NC, 4NC Electrical ife 1, Minimum Mechanical ife 1, Minimum 25, Minimum Termination Solder/Tab Terminals PCB & Solder Terminals Screw Terminals Degree of Protection IP65 (IEC 6529) IP65 (IEC6529) Operator: IP65 (IEC6529) Terminal: IP2 (when XW9Z-V2MF is installed) Approvals Safety Control X6 and XA series U recognized. AS-Interface Safety at Work ight Curtains Phone: 8.894.412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

22mm XW E-Stops 22mm XW E-Stops Key features: The depth behind the panel can be as little as 46.4 mm for 1 to 4 contacts (with terminal cover) for illuminated and non-illuminated units. IDEC s original Safe break action ensures that the NC contacts open when the contact block is detached from the operator. 1 to 4NC main contacts and 1 or 2NO monitor contacts Push-to-lock, Pull or Turn-to-reset operator Models with mechanical indicator on the operator body show the normal/latched status (green: normal). Safety lock mechanism (IEC6947-5-5, 6.2) Degree of protection IP65 (IEC6529) Fingersafe (IP2) terminals Three button sizes: ø38, ø4 and ø6 mm Push-ON illumination type available (4mm mushroom head) Direct opening action mechanism (IEC6947-5-5, 5.2, IEC6947-5-1, Annex K) ohs compliant (EU directive 22/95/EC). U c-u listed. EN compliant U NISD category emergency stop device (File# E35148) Specifications Applicable Standards Operating Temperature Operating Humidity Storage Temperature Operating Force IEC6947-5-5, EN6947-5-5, JIS C821-5-1, U58, U991, NFPA79, CSA C22.2 No. 14, GB1448.5 Non-illuminated: 25 to +6 C (no freezing), Illuminated: 25 to +55 C (no freezing) 45 to 85% H (no condensation) 45 to +8 C Push-to-lock: 32N Pull-to-reset: 21N Turn-to-reset:.27N m Minimum Force equired for Direct Opening Action 8N Min Operator Stroke equired for Direct Opening Action 4mm Maximum Operator Stroke 4.5mm Contact esistance 5mΩ maximum (initial value) Contact Material Gold plated silver Insulation esistance 1MΩ minimum (5V DC megger) Impulse Withstand Voltage 2.5kV Pollution Degree 3 Operation Frequency 9 operations/hour Shock esistance Operating extremes: 15m/s 2 (15G), Damage limits: 1m/s 2 (1G) Vibration esistance Operating extremes: 1 to 5Hz, amplitude.35mm acceleration 5m/s 2 Damage limits: 1 to 5Hz, amplitude.35mm acceleration 5m/s 2 Mechanical ife 25, operations minimum Electrical ife 1, operations minimum, (25, operations minimum @ 24V AC/DC, 1mA) Degree of Protection Operator: IP65 (IEC6529) Terminal: IP2 (when XW9Z-V2MF is installed) Terminal Style M3. screw terminal ecommended Tightening Torque for ocking ing 2.N m Wire Size 16 AWG max Weight ø4mm: 72g ø6mm: 81g U File #E68961 CCC No. 2513515897 Overview Interlock Switches Enabling Switches Safety Control ight Curtains AS-Interface Safety at Work Phone: 8.894.412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

22mm XW E-Stops Safety Control Enabling Switches Interlock Switches Overview Standard Button Without Mechanical Indicator Style Illuminated 1 Operator Type 4mm Mushroom 6mm Mushroom 4mm Mushroom with built-in 24V AC/DC ED Monitor Contact Main Contact Part Number 1NO 1NC XW1E-BV411M- 2NC XW1E-BV42M- 2NO 2NC XW1E-BV422M- 1NO 3NC XW1E-BV413M- 4NC XW1E-BV44M- 1NO 1NC XW1E-BV511M- 2NC XW1E-BV52M- 2NO 2NC XW1E-BV522M- 1NO 3NC XW1E-BV513M- 4NC XW1E-BV54M- 1NO 1NC XW1E-V411Q4M- 2NC XW1E-V42Q4M- 2NO 2NC XW1E-V422Q4M- 1NO 3NC XW1E-V413Q4M- 4NC XW1E-V44Q4M- 4mm Mushroom 1NO 2NC XW1E-TV412Q4M- Push-ON ED 2 1. The light is independent of the position of the switch, except for push-on ED type. 2. The light only operates when the switch is pressed as it is internally wired. Part Numbers Smooth Button With Mechanical Indicator Style Illuminated Operator Type 38mm Mushroom 38mm Mushroom with built-in 24V AC/DC ED 1 XW Series EMO Switches Style NC Main Contact NO Monitor Contact Part Number 1NC - XW1E-BV41M-H-EMO 4mm Mushroom 2NC - XW1E-BV42M-H-EMO 3NC - XW1E-BV43M-H-EMO 4NC - XW1E-BV44M-H-EMO 1NC 1NO XW1E-BV411M-H-EMO 2NC 1NO XW1E-BV412M-H-EMO 3NC 1NO XW1E-BV413M-H-EMO 2NC 2NO XW1E-BV422M-H-EMO FB Enclosures with XW E-Stops Style Style NC Contact NO Contact Part Number Monitor Contact Main Contact Part Number 1NC XW1E-BV4TG1M 2NC XW1E-BV4TG2M 3NC XW1E-BV4TG3M 4NC XW1E-BV4TG4M 1NO 1NC XW1E-BV4TG11M 1NO 2NC XW1E-BV4TG12M 1NO 3NC XW1E-BV4TG13M 2NO 4NC XW1E-BV4TG22M 1NC XW1E-V4TG1Q4M 2NC XW1E-V4TG2Q4M 3NC XW1E-V4TG3Q4M 4NC XW1E-V4TG4Q4M 1NO 1NC XW1E-V4TG11Q4M 1NO 2NC XW1E-V4TG12Q4M 1NO 3NC XW1E-V4TG13Q4M 2NO 2NC XW1E-V4TG22Q4M Note: Pushlock pull/turn reset switches are locked when pressed, and reset when pulled or turned clockwise. 1. ED lamp is not removable. 2NC FB1W-XW1E-BV42M ight Curtains AS-Interface Safety at Work 4mm Push-lock Turn/Pull eset 4mm Push-lock Turn/Pull eset Illuminated* 6mm Push-lock Turn/Pull eset 1NC 1NO FB1W-XW1E-BV411M 2NC 2NO FB1W-XW1E-BV422M 3NC 1NO FB1W-XW1E-BV413M 4NC FB1W-XW1E-BV44M 2NC FB1W-XW1E-V42M 1NC 1NO FB1W-XW1E-V411M 2NC 2NO FB1W-XW1E-V422M 3NC 1NO FB1W-XW1E-V413M 4NC FB1W-XW1E-V44M 2NC FB1W-XW1E-BV52M For added safety, Switch 1NC 1NO FB1W-XW1E-BV511M Guards and Nameplates can be 2NC 2NO FB1W-XW1E-BV522M used with E-Stop Enclosures 3NC 1NO FB1W-XW1E-BV513M *ED illumination voltage: 24V AC/DC 4NC FB1W-XW1E-BV54M Phone: 8.894.412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

22mm XW E-Stops Contact atings ated Insulation Voltage (Ui) ated Current (Ith) 25V ated Operating Voltage (Ue) 3V 125V 25V ated Operating Current Main Contacts (NC) Monitor Contacts (NO) AC 5/6Hz DC AC 5/6Hz DC 5A esistive oad (AC-12) 5A 3A Inductive oad (AC-15) 3A 1.5A esistive oad (DC-12) 2A.4A.2A Inductive oad (DC-13) 1A.22A.1A esistive oad (AC-12) 1.2A.6A Inductive oad (AC-14).6A.3A esistive oad (DC-12) 2A.4A.2A Inductive oad (DC-13) 1A.22A.1A Minimum applicable load: 5V AC/DC, 1mA (reference value). The rated operating currents are measured at resistive/inductive load types specified in IEC 6947-5-1. Illuminated Unit ED atings Operating Voltage Current 24V AC/DC ±1% 15mA Part Number Key XW1E - V 4 TG 11 Q4M Illumination B: : Illuminated ED T: Illuminated Push-ON ED Mushroom Size 4: ø4mm 5: ø6mm (non-illuminated only) Indicator TG: w/green mechanical indicator blank: w/o indicator Contact Configuration 11: 1NO - 1NC 2: 2NC 13: 1NO - 3NC 4: 4NC 22: 2NO-2NC 12: 1NO-2NC (Push-ON ED only) 1: 1NC (EMO switch only) 3: 3NC (EMO switch only) Mounting Hole ayout øa Y Panel Cutout.8 max. +.4 X +.2 3.2 +.4 Measurements Size øa X & Y 4mm 22.3 +.4 7mm min Depth Behind the Panel Depth (mm) Description 46.4 with indicator, 1-4 contacts, both illuminated and non-illuminated 48.7 w/o indicator, 1-4 contacts, both illuminated and non-illuminated Color : red with indicator -: red w/o indicator -H-EMO: red w/o indicator with EMO engraving Voltage Code Blank: Non-illuminated Q4: Illuminated 24V AC/DC Terminal Arrangements (Bottom View) 4NC 1NO-3NC 2NC 1NO-1NC 2NO-2NC 1NO-2NC Illuminated ED *4 *3 ED *4 *3 *3 *4 *4 *3 *3 *4 ED *4 *3 *4 *3 *3 *4 ED *4 *3 *3 *4 *4 *3 *3 *4 ED *4 *3 Push-ON 1 2 3 4 ED 2 1 Terminal Marking Description Contact Type 11 12 1-2: NC main contact 3-4: NO monitor contact Contact Number (1-4) Starting with the contact on in a 34 33 counterclockwise direction. Note: (Example: 1NO-3NC contact) 1: contact on the 2: contact on the eft 3: contact on the Bottom 4: contact on the ight 21 22 42 41 Overview Interlock Switches Enabling Switches Safety Control ight Curtains AS-Interface Safety at Work Phone: 8.894.412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

22mm XW E-Stops Overview XW Standard Button Without Indicator (with terminal cover) 18.5 2.1 Panel Thickness.8 to 6 Panel Thickness.8 to 6 ø Dimensions (mm) XW Standard Button ED Illuminated/Push-ON Without Indicator (with terminal cover).8 max. Illuminated 18.5 2.1 +.2 3.2 +.4 +.4 Panel Thickness.8.8 to to 6 6.8 max. +.4 +.2 3.2 +.4 ED Push-ON Type 18.5 18.5 2.1 2.1.8 max. +.4 +.2 3.2 +.4 M3 Terminal M3 Terminal Screw Screw Gasket Gasket.5 ocking ing ocking ing.5 Push-ON 18.5 2.1 ø4 M3 Terminal Screw Gasket ocking ing ing.5 ø4 M3 Terminal Screw Interlock Switches XW9Z-V2M IP2 Protection Cover XW9Z-V2MF 47.2 48.7 32 AS-Interface Safety at Work.5 ø4 Illuminated 18.5 2.1 2.8 48.7.8 max. +.4 32 ø6 +.2 3.2 IP2 Protection Cover XW9Z-V2M XW9Z-V2MF 47.2 48.7 32 ø4mm Button XW9Z-V2M 32 ø4mm Button +.4 32 ø6mm Button Enabling Switches XW Smooth Button With Indicator 44.9 (with terminal cover) 46.4 34.3 18.5 2.1 M3 Terminal Screw Gasket ø38 XW Smooth Button ED Illuminated/Push-ON With Indicator (with terminal cover) Illuminated 18.5 2.1 2.8.8 max. +.4 +.2 3.2 +.4 Safety Control EMO XW9Z-V2M ocking ing.5 Panel Thickness 1 to 4.8 max. +.2 3.2 18.5 2.1 44.9 46.4 34.3 M3 Terminal Screw Gasket.5 ight Curtains.8 max. +.2 3.2 ø38 +.4 +.4 +.4 +.4 XW9Z-V2M ocking ing Panel Thickness 1 to 4 47.2 48.7 32.2 47.2 48.7 32.2 18.5 2.1 M3 Terminal Screw ubber Gasket 21 ø4 18.5 2.1 M3 Terminal Screw ubber Gasket 21 ø4 XW9Z-V2MF ocking ing Panel Thickness.8 to 6 XW9Z-V2M ocking ing Panel Thickness.8 to 6 Phone: 8.894.412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

22mm XW E-Stops Accessories: s Appearance Description Part Numbers Accessories: Nameplates for contact block IP2 Fingersafe Cover XW9Z-V2M XW9Z-V2MF Appearance egend Part Number Inner Ø Outer Ø (blank) HWAV- 22mm 6mm Emergency Stop HWAV-27 22mm 6mm (blank) HWAV5-22mm 8mm Emergency Stop HWAV5-27 22mm 8mm Use 6mm nameplates for 39mm and 4mm mushroom buttons and 8mm nameplates for 6mm mushroom buttons. emoving the Contact Block First unlock the operator button. Grab the bayonet ring j and pull back the bayonet ring until the latch pin clicks k, then turn the contact block counterclockwise and pull out l. k Turn counterclockwise j Grab k Pull Notes for removing the contact block j Grab Accessories: Shrouds Appearance Part Numbers E-Stop Types Applicable Standards Operating Instructions Panel Mounting Bayonet ing 1. When the contact block is removed, the monitor contact (NO contact) is closed. 2. While removing the contact block, do not exert excessive force, otherwise the switch may be damaged. 3. An ED lamp is built into the contact block for illuminated pushbuttons. When removing the contact block, pull the contact block straight to prevent damage to the ED lamp. If excessive force is exerted, the ED lamp may be damaged and fail to light. HW9Z-KG1 HW9Z-KG2 HW9Z-KG3 HW9Z-KG4 38mm, 4mm Mushroom Head 38mm, 4mm, and 6mm Mushroom Head 38mm, 4mm Mushroom Head 38mm, 4mm Mushroom Head SEMI S2-73, 12.5.1 Compliant SEMI S2-73, 12.5.1 & SEMATECH Compliant SEMI S2 Compliant (Approved by TUV) SEMI S2 Compliant (Approved by TUV) & SEMATECH emove the locking ring from the operator and check that the rubber gasket is in place. Insert the operator from panel front into the panel hole. Face the side without thread on the operator with marking upward, and tighten the locking ring using ring wrench MW9Z-T1 to a torque of 2. N m maximum. ubber Gasket Notes for Panel Mounting Operator without thread marking ocking ing To prevent the XW emergency stop switch from rotating when resetting from the latched position, use of an anti-rotation ring (HW9Z-) or a nameplate is recommended. Installing the Contact Block First unlock the operator button. Align the small q marking on the edge of the operator with the small p marking on the yellow bayonet ring. Hold the contact block, not the bayonet ring. Press the contact block onto the operator and turn the contact block clockwise until the bayonet ring clicks. q marking j Push p marking k Turn clockwise Overview Interlock Switches Enabling Switches Safety Control ight Curtains AS-Interface Safety at Work Phone: 8.894.412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

22mm XW E-Stops Overview Notes for installing the contact block Make sure that the bayonet ring is in the locked position. Check that the two projections on the bayonet ring are securely in place. atched Unlatched IP2 Protection XW9Z-V2MF To install the IP2 protection cover, align the marking on the cover with the marking on the contact block, and press the cover toward the contact block. Projections (Press) Wiring The applicable wire size is 16 AWG maximum. Screw Terminal marking marking Interlock Switches Enabling Switches Safety Control 1. Wire thickness: AWG18 to 16 2. Tighten the M3 terminal screw to a tightening torque of.6 to 1. N m. Installing and emoving s XW9Z-V2M To install the terminal cover, align the marking on the terminal cover with the marking on the contact block. Place the two projections on the bottom side of the contact block into the slots in the terminal cover. Press the terminal cover toward the contact block. j Place the projections on the contact block marking k Press the terminal cover To remove the terminal cover, pull out the two latches on the top side of the terminal cover. Do not exert excessive force to the latches, otherwise the latches may break. 1. Once installed, the XW9Z-V2MF cannot be removed. 2. The XW9Z-V2MF cannot be installed after wiring. 3. With the XW9Z-V2MF installed, crimping terminals cannot be used. 4. Make sure that the XW9Z-V2MF is securely installed. IP2 protection cannot be achieved when installed loosely, and electric shocks may occur. Contact Bounce When the button is reset by pulling or turning, the NC main contacts will bounce. When pressing the button, the NO monitor contacts will bounce. When designing a control circuit, take the contact bounce time into consideration (reference value: 2 ms). ED Illuminated Switches ED lamp is built into the contact block and cannot be replaced. Installing the Anti-rotation ing HW9Z- Align the side without thread on the operator with marking, the small s marking on the anti-rotation ring, and the recess on the mounting panel. Without thread marking on the anti-rotation ring marking Markings Anti-rotation ing (HW9Z-) ight Curtains Pull out the latches AS-Interface Safety at Work Phone: 8.894.412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com