Technical Documentation Radial Pump with Canned Motor Y-1638-MM

Similar documents
Technical Documentation Regenerative Turbine Pump with Canned Motor Y-2951-W-MM

Technical Documentation Radial Pump with Canned Motor MY-3-MM

HL (AZH) LIMIT SWITCHES

Product Data Sheet DV5214 NU

TOE-MN / MA / MI Series. Heat transfer pumps for heat transfer oils up to 350 C

HL (AZH) Limit Switches

16mm miniature rocker solenoid valve with isolating diaphragm for special applications

2/2 and 3/2-way Flipper Solenoid Valve, with hermetic isolation of fluid

SEMA Side channel pumps PN 25 (40) Glandless because of magnetic drive

Product Data Sheet DV4118 N

Product Data Sheet 8414 NGH

Pressure sensor for liquid and gaseous media QBE620-P...

Product Data Sheet 614 N/2HH-169 The engineer's choice

Product Data Sheet 3214 JH3-195

Product Data Sheet 4414/2H

Owner s Manual. DC-DC Step Down Converter

CRNE15-03 A-FGJ-G-V-HQQV 3x HZ

Liquid ring vacuum pumps with magnetic coupling

Product Data Sheet 4118 N/ The engineer's choice

our contribution for Sealless Magnetic Coupled Multistage Centrifugal Pumps Type HZM / HZMR / HZMB environmental protection

2/2 and 3/2-way Flipper Solenoid Valve, with hermetic isolation of fluid

Centrifugal pumps. Main catalogue.

Product Data Sheet 4184 N/17X. The engineer's choice

Product Data Sheet 4184 NGX

Contents. Identification

NB80-160/161 A-F2-A-BQQE

Product Data Sheet 3214 J/2H3F-191

Product Data Sheet 8412 N/ The engineer's choice

Electronic Circuit Breaker ESS20-0..

HTM Circulation Pumps acc. to DIN EN 733 Type NKLs

via M3 DIN 931 hexagonal bolts in the groove or spring clips with inside diameter mm (not included)

Product Data Sheet 4184 NXHH

Sealless Magnetic Coupled Multistage Centrifugal Pumps with Priming Stage Type HZSM / HZSMB / HZSMR / HZSMA / HZSMAR

SCHMITT. product information. Kreiselpumpen. U Pump Series. normal priming, centrifugal pumps with a single mechanical seal.

Proportional solenoid valve for pneumatic application V PR M

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

PSR Centrifugal pumps

Chemical Motor Pump Unit BN

product specification

Product Data Sheet 8412 NHU-519

Vertical Immersion Pump VTP - BBF

NBE40-125/139 AS-F2-A-BAQE

Product Data Sheet 4184 NXHH

Product Data Sheet 632 NU-006

2/2 or 3/2 way direct acting rocker solenoid valve

Data sheet. Page: 1 / 7. ETL GG AV11D BKSBIE3M Inline pump. Operating data. Design

our contribution for environmental protection Sealless magnetic coupled centrifugal pumps acc. to EN Type NML / NMB

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

EExe and EExi terminal boxes in polyester and aluminium for Ex areas

Data sheet. Page: 1 / 5. ETL GGSAV11D BKSBIE3 Inline pump. Operating data. Design

Pan and Tilt Head CDD2416-T

Sealless Magnetic Coupled Hot Oil Circulation Pumps acc. to DIN EN / ISO 2858 Type NMWR / NMWB / NMW. our. contribution for

our contribution for Sealless Magnetic Coupled Multistage Centrifugal Pumps Type HZM / HZMR / HZMB environmental protection

Filter module AF Features. MAHLE Industrialfiltration is now Filtration Group. For more information, visit

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3

Unused flameproof threads for cable glands have to be closed with certified plugs.

Differential Pressure Sensors

CRE45-1 A-F-A-E-HQQE 3x HZ

TOE-GN / GA / GI Series. Heat transfer pumps for heat transfer oils up to 350 C and hot water up to 160 C

Electromagnetic Flow Monitor magphant

MAX FLUID TEMPERATURE

Operating Instructions. Pneumatic Control Valve Low Temperature. Type Series GS3

CRE5-16 A-A-A-E-HQQE 3x400 50HZ

Proportional solenoid valve for pneumatic application V PR M

NKE80-160/175A2F2AE-SBQQE

Polyester enclosures CP series

4314/17T. Product Data Sheet INDEX

Automatic metal-edge filter AF 75 S / AF 95 S

AC Fans. AC Fans Overview 117. AC Axial Fans 118. AC Radial Fans 138. Technology. DC Axial Fans. DC Radial Fans. Specials. ACmaxx Axial Fans.

System 8. Solenoid Coils Armature Assemblies Valve Systems. Nass Controls LP Nass Magnet GmbH Precision Controls Kft.

Side channel pumps PN 16 SOH - SOHB - SOHM. Self-priming centrifugal pumps. Technical description

Lowara. Centrifugal electric pumps made of AISI 316 stainless steel in compliance with EN 733. SH Series. 50 Hz

Remote Process Actuation Control System AirLINE - Rockwell 1734 Point I/O System

4 submersible pumps powered by renewable energy sources

AF40... AF96 3-pole contactors Technical data

UNIT TAG: TYPE OF SERVICE: SUBMITTED BY: APPROVED BY: ORDER NO.: CME3-7 A-S-I-E-AVBE. Pump Data

SIHI LPH-X - Liquid Ring Vacuum Pump Two Stage

Steering column and sensor

HL (AZH) Limit Switches

NBE50-250/205 A-F2-A-BAQE

CME1-4 A-R-I-E-AQQE S-A-D-N

3/2-way Small Solenoid Valve, G 1/8 - G 1/4 and sub-base

Operating Instructions. Angle Seat Control Valve. Type 7020

Safety rope switches with reset for emergency stop

Immersion Pumps PS and PSL ( Slurp Pump ) sealless

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency

Lowara. Centrifugal Electric Pumps Manufactured in AISI 316 Stainless Steel in Compliance with EN 733. SH Series. 60 Hz

GMP-Type. Key Features: Integrated Motor-Pump Units

2/2 and 3/2 way Flipper Solenoid Valve, with hermetic isolation of fluid. Low dead volume, low internal volume. High chemical resistance

Motor Starter Reverse MSR22-FBP

1. SPECIFICATION. Altitude of motor installation. Information: Resistance and temperature specifications of the PTC thermistor / posistor/.

self-priming thermoplastics magnetic drive pumps

2/2 or 3/2-way Miniature Rocker Solenoid Valve

Volute Casing Pumps LSN. according to iso 2828 / ISO 5199

Ex UPS standard Series 8265

Incremental encoders Solid shaft with clamping or synchro flange pulses per revolution programmable

User Manual Rittal PMC UPS 6kVA

SIHI LPH-X - Liquid Ring Vacuum Pump Two Stage

CRNE5-10 A-FGJ-G-E-HQQE 3x400 50HZ

Volute Casing Centrifugal Pumps in In-line Design with Magnetic Drive. Series CNI-M

Transcription:

Technical Documentation Radial Pump with Canned Motor Y-1638-MM

Technical Documentation Radial Pump with Canned Motor Y-1638-MM 816 847 816 847 230 230 210 210 310 310 Sleeve Bearing: Iglidur Sleeve Bearing: SiC Description Applications Hermetically sealed small centrifugal pump, normal or self-priming with canned motor. Impeller (230) and inner magnet (847) are assembled to the same shaft (210), the shaft is supported by a medium-lubricated sleeve bearing (310). The power transmission from motor to shaft is produced by a rotating field, generated by coils, directly to the inner magnet. The can (816) separates the pumping chamber from the atmosphere. An integrated electronic circuit provides for the rotating field and controls the pump speed. The drive is free from bearings and rotating components: No maintenance is necessary in standard operation. The pump can be used in the following fields of application, e.g.: Temperature controlling and industrial cooling cooling of machines, systems and production processes cooling of industrial and medical lasers climatisation of control cabinets tempering devices in laboratory applications Further applications drinking water supply in railcars and on ships etc. 2

Technical Data Pumped media Temperature / Medium Installation Ambience Static system pressure Motor power Nominal voltage Operating voltage Current consumption Fuse Speed Direction of rotation Protection class Sound pressure level Connecting wire Cable connection Clear or unclear liquids or mixtures without solids and with good lubricating qualities, not aggressive to the pump components, density and viscosity similar to water. Other liquids on request. - 30 C up to +80 C (- 22 F up to + 176 F), medium has to be liquid! Dry installation in buildings or in roofed places outdoors. Not permitted in Ex-zones. - 30 C up to 40 C (- 22 F up to + 176 F) ambient temperature, max. 80 % air humidity. Protect the pump against ambient atmosphere or vapours with high concentrations of acids or solvents. max. 2.5 bar (max. 36.3 psi) max. 180 W (0.23 HP), depending on load and speed 24 V 18 to 28 V max. 7.5 A, depending on load and speed 10 A 2000 to 6000 rpm, possible parameters set by Speck Pumpen Left and right possible IP 54, higher degree of protection on request max. 46 db(a) in a distance of 1 m ( 3.3 ft) to all sides 1000 mm +/- 20 mm (39.3 +/- 0,8 ) insulating hose with loose wire-endings 50 mm (1.9 ), isolated without ferrules, 5 mm (0.2 ) stripped. See detailed information in table wire specification M16 x 1.5 plastics black Pumping capacity Plastic casing H max. 50 m (164 ft), Q max. 9 l/min (2.4 USGPM) Stainless steel casing H max. 60 m (197 ft), Q max. 9 l/min (2.4 USGPM) Lifetime Protection against dry running Blocking protection Overload protection Max. surface temperature approx. + 90 C (+ 194 F) Storage temperature Lacqueur 20,000 hours of operation according to standard mode of operation Not existing, the pump has to be protected against dry running by the user In the state of a blocked impeller the starting attempts will be continued indefinitely Integrated electronics automatically reduce motor speed when reaching max. admissible motor temperature - 40 C up to + 120 C (- 40 F up to + 248 F) Motor casing powder-coated RAL 9005 black mat, pump housing unpainted Weight Plastic casing 1,5 kg (3.3 lbs) Stainless steel casing 1,9 kg (4.2 lbs) 3

Dimensions 128 151 22 29 84 G 1/4 G 1/4 50 Ø 88 92 8 8 7 Ue* 40 70 90 84 106 129 1 1 Länge mit Verschlussschraube Material Casing parts PPS (polyphenylensulfide with 40% fibre glass) 1.4581 CrNiMo-cast steel 1.4581 CrNiMo-cast steel Impeller 1.4408 CrNiMo-cast steel 1.4408 - CrNiMo-cast steel, coated with Ni-SiC 1.4408 - CrNiMo-cast steel, coated with Ni-SiC Shaft 1.4462 CrNiMo-steel 1.4462 CrNiMo-steel 1.4462 CrNiMo-steel Sleeve bearing Iglidur Iglidur SiC Separating can PPS (polyphenylensulfide with 40% fibre glass) PPS (polyphenylensulfide with 40% fibre glass) PPS (polyphenylensulfide with 40% fibre glass) O-rings FKM FKM FKM 4

H [m] Förderhöhe Hauteur manométrique Capacity Q [U.S.GPM] 0 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 Hydraulic specifications and power consumption 60 50 40 30 20 10 1.4581 PPS 200 175 150 125 100 75 50 25 H [feet] Total head 0 0 P [kw] P1 Leistungsbedarf Puissance absorbée 0,200 0,175 0,150 0,125 0,100 0,075 0,050 0,025 1.4581 PPS 0.25 0.20 0.15 0.10 0.05 P [HP] P1 Power consumption 0 0 1 2 3 4 5 6 7 8 9 0 Förderstrom / Débit Q [l/min] 2000 6000 1/min - rpm - tr/min Every operating point can be reached within these characteristic fields by setting different drive parameters. The characteristic fields are applicable for the delivery of water of 20 C (68 F) temperature and an ambient temperature of 20 C (68 F). The tolerance of total head and capacity is ±10%, performance tolerance is +10%. If the property of the pumped media differs, the characteristic fields change. The power consumption P1 specifies the electrical power input. 5

Fixing and installation Pump connections The preferred position for the installation of the pump is a horizontal position. By loosening the tension clamp, the position of the pump connections (state of delivery: on top) can be removed deliberately. For Y-1638-MM in the ranges of 90 to the left (9 o clock position) or 90 to the right (3 o clock position). Clamping torque is 3-5 Nm. Avoid an incident flow from below. Installing instructions An open and well-ventilated place has to be chosen for the installation of the pump. Foot fastening with four M6 screws in an appropriate, accessible place. The connections of suction and discharge pipe to the pump casing and the pump connections in general should be assembled tension free. Size of pipes should not range below ¼.Do not use any kind of insolating material around the pump.check all pipes according to fixed position and tightness. Electrical connections The connecting wire has to be installed tension free. Electrical Installation Connect the red strand 2,5 mm² with the 24 V- positive pole of the power supply unit. Connect the black strand 2,5 mm² with the 24 V-negative pole of the power supply unit. Pay attention to use well-dimensioned cable connections. In addition, optional features are available: Option Adjustable speed: Motor speed is defined by the control lines proportional to applied voltage (0-10 V) or current (0 20 ma). Speed depends on the particular programming of the motor. If the control lines are not connected, the motor runs with a programmed speed for 0 V, respectively for 0 ma. Connect the yellow strand 0,75 mm² with the 0 10 V-positive pole of the control voltage source or the grey strand with the 0-20 ma-positive pole of the control power source. Connect the black strand 0,75 mm² with the negative pole of the control voltage or power source. Option Turn on/off: The motor can be turned on and off by the control line Active Low without cutting off power supply. Connect the green strand (Active Low) with Signal GND (black strand 0,75 mm²) to turn off the motor. Wire specification Supply lines Function Cross sections Colour +24 VDC AWG 14 ˆ= 2.5 mm² red Power GND AWG 14 ˆ= 2.5 mm² black or blue Control lines Function Cross sections Colour Signal GND AWG 20 ˆ= 0.75 mm² black option available Active Low AWG 20 ˆ= 0.75 mm² green option available Tach Out AWG 20 ˆ= 0.75 mm² brown option available Control Voltage AWG 20 ˆ= 0.75 mm² yellow option available Control Current AWG 20 ˆ= 0.75 mm² grey option available Interface AWG 20 ˆ= 0.75 mm² white only applicable by Speck Pumpen Interface AWG 20 ˆ= 0.75 mm² blue only applicable by Speck Pumpen Single wires bound in an insulating hose 6

Optional Speed signal A speed proportional open collector square signal is issued by the brown control line (Tach Out), referring to signal GND. Speed [Hz] = frequency of rectangular signal [Hz]. Ic Restistance R has to be selected according to applied voltage VDC, that the current lc may not exceed 20 ma. At VDC = 10 V, R usually is approx. 1 kω. Notice Supply ground (Power GND) and signal ground (Signal GND) are connected internally! R +VDC Tach Out Signal GND Inverse-polarity protection Supply lines (+24 VDC and Power GND) are not protected against inverse polarity, but resitant to inverse politarity for a short term. In this case the inverse polarized supply voltage is short-circuited (max. 100 A for 100 ms). Control lines are protected up to ±25 V (right and inverse polarized). Initial operation The hydraulic system has to be completely filled and bled before the first start up. The pump has to be filled with the pumped medium. For bleeding the system please pay attention to the instructions by the manufacturer. Shut-off valves on suction side and on pressure side have to be opened completely. The delivery of the pump medium has to be initiated immediately after commissiong the pump (no more than 5 seconds). If priming does not occur, the pump has to be turned off to avoid damages of dry running. Trouble shooting Disturbance Cause Action Pump does not deliver Supply suction pipe and pump are not Fill or bleed pump and/or pipes bled correctly or not filled completely completely Pump delivers with interruptions Delivery performance too low Motor does not run Hydraulic parts of the pump are blocked or stuffed by solids Hydraulic parts of a pump are dirty, sticky, incrusted or worn out Supply suction pipe and pump are not bled correctly or not filled completely Electronical parts too hot: Motor reduces speed Connect motor to the power supply correctly Disassemble pump, remove solids Disassemble pump, clean pump parts Fill or bleed pump and/or lines completely. Keep motor ventilated 7

UL approvals of material used Component Material, manufacturer, comment UL Motor electronics PCB and plug as well as plastic parts being in contact with conductors UL94 V-0 Casting compound Motor casing WEVO casting compound PD 4431 FL The electronic components are covered, only electrolyte capacitors and connector pins protrude from the compound. Die-cast aluminium Polyester resin based Interpon 610 powder coating UL94 V-0 (UL / CSA-File E108835) Not applicable UL 1332 Separating can ALBIS PLASTIC GmbH, Tedur L 9107-1 (PPS-GF40) UL94 V-0 (UL / CSA-File E80168) Impeller 1.4408 Not applicable CrNiMo-cast steel Pump casing 1.4581 Not applicable Strands ALBIS PLASTIC GmbH, Tedur L 9107-1 (PPS-GF40) The connecting cable has single strands which are bundled in an insulating hose. UL94 V-0 (UL / CSA-File E80168) UL3266 / CSA AWM I A/B Insulating hose Isotex (combination of glassfibre and silicon) UL-1441 / UL94 V-0 Cable gland Jacob GmbH, polyamide PA6 UL 514B (UL / CSA-File E140310) Systemtechnik GmbH Postfach 1453 D - 91142 Roth / Germany Regensburger Ring 6-8 D - 91154 Roth / Germany Tel.: +49 (0) 9171 809 0 Fax: +49 (0) 9171 809 10 info@speck.de www.speck.de 8