User Manual. Model: FSL300 Dual Port Laser Fume Extractor

Similar documents
quatroair.com AIR TECHNOLOGIES INC.

Operation Manual for ARM-EVAC 150 Fume Extraction System

FA1 Series Air Filtration System. Operations Manual

INSTALLATION GUIDE. Greentek. Residential use only MODEL HS 3.0

DESKTOP CONTAINMENT SYSTEM

Soldering/Desoldering. Convection Rework. Fume Extraction. Fluid Dispensing

Installation and Operating Manual

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com BVX-100. Fume Extraction System _B

The BVX-100 Fume Extraction System

SPH General Manual 400 Series

READ AND SAVE THESE INSTRUCTIONS. Air Boss MP600M Vertical Air Flow Mist Precipitator Industrial Applications. TRION

X-3400A, X-3500, X-3700 OWNER S MANUAL PLEASE READ AND SAVE THESE INSTRUCTIONS

EC 200 EC 300 GE 360 GE 400 GE 600 L-S BM

MODEL FA1 Mini Air Filtration System. Operations Manual

Videojet Fume Extractor Preventive Maintenance Guide

Operating Instructions. International English. CCS Dust Extractor

Installation & Service Manual for Portable Fume Collector. Model PFC-800

UltraCell XX25-A1. Operating Manual

MODEL FA5 Air Filtration System. Operations Manual

Owner s manual for installation, usage and maintenance

Loctite Air Filtration System Part Number EQUIPMENT. Operation Manual

TECHNICAL INFORMATION S2 Canister Vacuums

Eurovacuum Installations and Operating manual EV Series Vacuum pumps Models

MG200 Filter system OPERATING INSTRUCTIONS FOR A BETTER WORKBENCH ENVIRONMENT FILTRONIC

Portable HEPA System

SafeFAST Top. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

SR500 PAPR How to Copyright 2015 by The S.E.A. Group 1

OPERATIONAL INSTRUCTIONS

ARM-EVAC 105. Central Filter Unit

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com BTX-208. Fume Extraction System _B

Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-10 RX-21 RX-25

Installation Operation and Maintenance Manual

ARM-EVAC 500 Central Filter Unit

INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS. Part Number: P DM

AMAIRCARE HEPA BYPASS AIR FILTRATION SYSTEM READ AND SAVE THESE INSTRUCTIONS! AIR CLEANERS/ FILTERS. Rules for Safe Installation and Operation

SilverOnyx 5 Speed Air Purifier. User Manual. - Version Store in a safe place for future reference.

HEPA AIR FILTRATION SYSTEM

Cleanshield HEPA 550 Owner s Manual

Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-40 RX-63 RX-100

Source Capture Air Purification System

Table of Contents. Safety Information Main Functions Set-Up Operation Maintenance Troubleshooting Specifications Customer Support Warranty Information

MODEL MC1500 Installation and Operation Manual Important:

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

SECTION AIR INTAKE SYSTEM

Operating Instructions For The X-Seal Manual Thermal Sealer

BIGLA30-T/BIELA14-T Event Codes Quick Reference EXPLANATION CORRECTIVE ACTION PARTS TO CARRY ON SERVICE CALL

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

Affordable portable filtration unit

Content 1. Laserline series 3

SilverOnyx 5 Speed Air Purifier. User Manual. - Version Store in a safe place for future reference.

Installation manual. Intake system and ventilation. Industrial engines DC09, DC13, DC16 OC16. 01:02 Issue 10 en-gb. Scania CV AB 2018, Sweden

BULL 240 EBS INDUSTRIAL VACUUM. Operator s Manual VAC.BULL240.EBS. SASE Company, LLC 2475 Stock Creek Blvd. Rockford, TN 37853

GSL Electronics Modified Sine Wave Power Inverters

NSGV PT-1000 PORTABLE WELDING STATION I, O & M MANUAL

HEAT/ COOL/ DEFROST CHEVROLET PICKUP CONTROL & OPERATING INSTRUCTIONS

AIR FILTRATION DEVICE

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

OmniAire Portable Air Cleaner OA1200PAC

PHOENIX MINI-GUARDIAN

The Anatomy of a Drum Filter

D-Series Blowers and Exhausters

Installation, Operation and Maintenance Manual

INSTALLATION / OPERATION / MAINTENANCE GUIDE

Portable filtration unit / 650 CFM (305 L/s) Portable filtration unit / 1500 CFM (710 L/s) For 1 or 2 arms configuration

MODEL MA4210 Installation and Operation Manual Important:

WELDING FUME EXHAUSTERS & ARMS

Airistar 100GT Owner s Manual Airistar 100GT Air Purifier

Smart Fume Extractor

Summary and Features. Model. Main Function Feather:

User s Manual D-Series Blowers and Exhausters

6 Litre Oil-Less Air Compressor

MIMPEN0410. Installation, operation and maintenance manual DMP-170, DMP-170S, DMP-270, DMP-270S, DMP-350, DMP-350S, DMP-450 & DMP-450S

5 Compact Vacuum Systems. Compact Vacuum Systems

Installation, Operation and Maintenance Manual

Multistage Air Filtration Systems Instruction Manual

Fume Extraction Planning Guide

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST FORD FAIRLANE & CROWN VICTORIA

PHOENIX GUARDIAN H. E. P. A. SYSTEM

Instruction Manual LAMI CORPORATION INC.

BRAVER UPS. (Uninterruptible Power System) User s Manual

Model G14SD Vapor Management System

INSTALLATION MANUAL. Ford 5.4L F

P&G MANUFACTURING INC.

Techlab - Matériaux de Référence certifiés et Equipements de Laboratoire -

OmniAire 2200 Operations and Maintenance Manual

Service Manual. Vacuum Cleaner. MODELS S171i / S172i

AdBlue Electric Transfer Pump 12V & 24V DC

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual

9 Replacing the routine maintenance parts

Grind Pro Series. Operator Manual. Manufacture by:

INSTALLATION MANUAL. Dodge 5.9L Cummins

16" STAND FAN WITH REMOTE

About Dustcontrol Filter Units

240V AdBlue Transfer Pump Stations

SPH-400 i Series General Manual

Troubleshooting Guide

OPERATIONAL INSTRUCTIONS

OUTLAW PB BATTERY DRY VACUUM

Smart Fume Extractor

Transcription:

User Manual Model: FSL300 Dual Port Laser Fume Extractor WWW.FSLASER.COM

1. Product Overview This high quality fume extractor featuring low noise brushless motor technology is designed for capturing dust particles and removing odors when cutting or engraving with the Full Spectrum Laser line of laser cutters. With dual air inlet ports, up to two lasers can be run at the same time using a single filter. Use only OEM replacement filters from Full Spectrum Laser in this machine to maintain top performance and warranty. 2. Unpacking Inspection Please check carefully to ensure that the following listed parts are included. If there are any missing or damaged items, please contact customer service. Name of Parts Qty Remarks Main Unit 1 Power Line 1 4 Hose 1 4 Air Inlet Cover 1 Large Pleated Prefilter HEPA Filter Cartridge Activated Carbon Lower Filter Cartridges The FSL300 has dual 4 air inlets to operate up to two machines. Use the hose cover when operating a single machine. 1 Installed 1 Installed 5 Installed

3. Unit Components

4. Specifications Model FSL300 Specifications Air Inlet Interface Input Voltage Maximum Power Noise Systemic Flow 2x 4 duct AC110V 700W <75dB 365 CFM Dimensions of Main Unit 21.6 16.3 51.2 Weight 165 lbs 5. Installation & Use instructions The FSL300 fume extractor features an efficient bottom up design. Exhaust fumes enter from the bottom, through a large pre filter, followed by a HEPA filter cartridge followed by 5x Activated Carbon Cartridges. 5.1 Filter Cartridge Installation Pull upward the two twist locks, and rotate them clockwise to the "OPEN" position to open the front panel. The filters are held down by two twist clamps which counteract the upward force exerted by the rising exhaust. Rotate the clamps to release the pressure holding down the filters.

Grasp the handle on top layer and pull out the filter elements one by one. After replacement, put back the elements in sequence from bottom to top one by one. The arrows on the cartridges indicate the direction of air flow and should be pointed up. After all cartridges are placed back, use a spanner to rotate clockwise the adjusting nut to tighten the cartridges down if necessary.

Rotate the twist clamps downward to lock the cartridges in place. The large pleated filter can be removed by twisting. 5.2 Cleaning and maintenance of Lower Compartment and Pre filter If contaminants are observed on the lower compartment through the front glass window, please follow these steps: Pull upward on the two door latches, and rotate clockwise in the "OPEN" position to open the front door. Wipe the clear glass of the front door and the interior side of the door plate. Vacuum the interior and the large pleated pre filter. Pull out the black dust collection drawer, discard any particles and clean. Pleated Pre Filter Cartridge Removal Hold the filter cartridges with two hands and rotate it towards the right to tighten or left to loosen. The pre filter cartridge and the machine bottom must be cleaned regularly (recommended at least weekly) to prevent the filter system from becoming clogged and causing premature failure.

5.3 Suction Duct Hose Installation The FSL300 has 2 air inlets to operate up two machines simultaneously. When operating a single machine, place the included 4 air inlet cover over one of the inlets to block suction from that inlet. Remove the hose from the package, and attach one end of the 4 duct flange on the top cover of the machine and the other end to your Full Spectrum Laser machine s outlet duct. Cover the extra inlet or hook up another hose (not included) to the second inlet if intending to operate a second machine. Do not introduce a bend radius of more than 10 on the hose. 5.4 Machine Operating Instructions Plug in and check if the power plug is properly fit into the socket. Turn on the power switch.

5.5 Control Panel Button Functions On/Off Button Pressing the power switch on the remote control or the machine control panel should cause the machine to start running and the orange light on the machine control panel should turn ON. Pressing the power button again should cause the machine to stop running and the orange indicator light on the machine control panel should turn OFF. Flow+ Button Press this button when the machine is running to increase the fan speed, the number on digital display increases in multiples of 10, the maximum number is 100 which means the machine is running in full speed. Flow Button Press this button when the machine is running, the number on digital display decreases in multiples of 10. Proper Fan Speed The fan speed should be set according to the actual requirements to remove all smoke without creating too much of a vacuum. During laser cutting, the laser machine should not fill up with smoke. If there is lingering smoke during cutting increase the fan speed. Too high a setting may cause the work piece to lift up and be pulled toward the vacuum created. In addition, too high a fan speed increases the power consumption as well as the noise level.

Time Set Button While the machine is running, press the Timer Set button, the digital display will show HXXX. Then press the Flow+/Flow buttons to adjust the shutdown timing. XXX represents the timer countdown in hours with a maximum of 300 hours and minimum of 1 hour. After you are satisfied with the setting, press the Timer Set button again and the digital display will show HXXX and start the countdown timer. For example, H005 represents that the machine will shut down automatically in 5 hours. This function is useful at the end of the day when you turn the laser off but still want to keep cleaning any smell residues that may remain inside the machine. Ok/Setting Button If the machine is in alarm status and buzzer sounds, press the Ok/Setting button to turn OFF the alarm. If the machine is not in alarm status, press the Confirm/Set button to check the total working hours of the machine.

10. Troubleshooting Make sure the power is switched off and unplugged before inspecting or repairing the machine! Problem 1 : Cause : Solution: Problem 2 : Cause: Solution: Problem 3 : Cause: Solution: The machine still works, but the air flow is very weak and suction power is greatly reduced. Air Inlet is blocked or foreign body exists inside the duct. The filter becomes saturated and hence gets blocked and gives an alarm. Usually only the pre filter gets clogged quickly with large particles and needs to be vacuumed or replaced. Turn off the power and open the top cover. Check if there is any foreign objects blocking the air inlet. Then check if the air vent is blocked or not. If the suction power of the empty loaded machine is normal, it means the filter needs to be replaced. The machine shuts down automatically after it is just started. Even if you restart the machine, the same problem happens again. The air flow through the machine is obstructed. As a result, the starting current of the fan becomes very high, hence the machine shuts down automatically for self protection. Turn off the power and open the top cover. Check if there is any obstructions in the air inlet or replace filters. Power switch is ON, but machine does not run and the power indicator does not light up. The fuse might be bad. The fuse needs to be replaced. Pop the fuse out from the power socket using a flat head screwdriver and replace.

If the problem remains after these inspections and maintenance are performed, please contact customer service. pg

7. Filter Use & Maintenance This product has consumable replacement filters. They need to be cleaned or replaced periodically to ensure proper operation. 1. Dust/grease Pan In the FSL300 fume extractor, exhaust is forced upwards. When the FSL300 fume extractor is turned off, large particles should fall down and be caught by the dust/grease pan. Empty the dust/grease pan out periodically to get rid of this debris. 2. Large Pleated Pre filter The large pleated pre filter removes the largest dust particles. Vacuum it periodically and replace it when the air flow is reduced and vacuuming is no longer effective. The large pleated pre filter can be removed by twisting it to the left. 3. HEPA Filter Cartridge Load the HEPA Filter Cartridge with the arrow pointing up on top of the large pleated filter and below the activated carbon filters. It should be immediately cleaned off by vacuuming when any accumulated dust affects the suction power. When cleaning does not help replace the Middle HEPA Filter with a new one. Remember to unlock the twist clamps to release the filters and relock the twist clamps when added back in. 4. Activated Carbon Filter Cartridges Load 5x Activated Carbon Filter Cartridges on top of the HEPA Filter Cartridge. The cartridges are marked with an arrow in the direction of airflow. In the FSL300 these cartridges should be loaded with the arrow facing up. If there is good airflow but the odors are not removed, the Activated Carbon Filter is consumed and must be

replaced. Remember to unlock the twist clamps to release the filters and relock the twist clamps when added back in. 8. Replacement Parts Name Remarks Pictures Large Pleated Pre filter HEPA Filter Lower Activated Carbon Filter Cartridges Filters large particles. Replace or clean weekly. Placed on top of the large pleated pre filter and below the Activated Carbon Cartridges. Removes small particles. Removes odors. 9. Important Use Considerations While using the machine, the ambient temperature range of the gas and the dust which is sucked into the air inlet should be within the range 15 60ºC. Never use the machine when the temperature is higher or lower than this temperature range. When using the machine,the humidity of the gas and the dust sucked into the air inlet should be between the range of 40% 80%. If the humidity is excessively high, the activated carbon filter element will become rapidly saturated with water and consumed.

Do not use this machine without all filter elements because the fumes or the dust particles may be sucked into the air blower and the control system causing damage. Any operation without all filter elements installed is not covered under warranty. Use only OEM replacement filter elements from Full Spectrum Laser. Do not continue to use the machine when the HEPA Filter Cartridge or the Pre Filter is clogged as this will increase motor wear and shorten the service life of the machine. Please clean and/or replace the filter elements regularly to ensure proper machine operation. The warranty will not cover any losses or damage that may be incurred by the user if instructions are not followed. 10. Contact Information Full Spectrum Laser LLC 6216 S Sandhill Rd, Las Vegas, NV 89120 Tel: (702) 802 3100 Fax: (702) 987 0150 http://fslaser.com/support