SPH General Manual 400 Series
|
|
- Everett Fowler
- 6 years ago
- Views:
Transcription
1 Operations & Maintenance Manual SPH General Manual 400 Series (SPH-415,416,425,426,4U6,4U5,4B5,4B6) Filename: Quatro/SPH-400 General 12/28/04 R Engineering Clean Air Hymus Blvd., Montreal, Quebec, Canada H9R 1C9 Tel.: (514) Fax: (514)
2 1.0 INTRODUCTION You are now the owner of a Quatro SPH system, an advanced effective indoor air purification system designed specifically to remove particulate matter and/or gas phase contaminants. You can expect a noticeable improvement in air quality as the SPH begins the process of reducing microscopic airborne particulate as well as harmful and odorous gases. 2.0 SAFETY PRECAUTIONS Read all of the instructions contained in this manual before operating this unit. Keep this manual, as it contains information for proper operation and maintenance. Keep all fastening hardware tight to ensure that the unit is in safe working condition. Disconnect power prior to accessing unit, when checking or replacing filters, or replacing motor brushes. All filters must be in place whenever this machine is in operation. Use only on a grounded electrical circuit; do not use any two-wire electrical prong adapters to defeat the three-pronged plug on the end of the cord. When servicing the motors be careful when touching the exterior of the motor as soon as it has been turned off; it may be hot enough to be painful or cause injury. With modern motors, this condition is normal when operated at rated load and voltage, as they are built to operate at higher temperatures. Do not substitute any other filters (particulate or chemical) for those supplied, as this will alter the design characteristics and may void warranty. DO NOT ACCESS UNIT UNLESS UNIT IS UNPLUGGED FROM RECEPTACLE (ITS POWER SUPPLY)! Warning: This is a class A product. In domestic environment, this product may cause radio interference in which case the user may be required to take adequate measures. 3.0 PRINCIPLE OF OPERATION The SPH features a progressive filtration sequence method of operation; 1) captures general particulate 2) HEPA filter removes microscopic particulate matter; 3) chemically adsorbs, reacts or scrubs toxic or nuisance gases; SYSTEM COMPONENTS CABINET: Attractive airbrushed finish. The SPH is mounted on casters to ease portability. STANDARD FILTER SEQUENCES (from top to bottom): BLOWER ASSEMBLY: The blowers are tested to ensure quiet, vibration-free operation. The blower(s) in the SPH-400 Series features a blower mounting system designed to reduce vibration and noise. CONTROLS: Externally visible: ON/OFF switch, fused internally, a potentiometer to adjust airflow as required. AIR SUPPLY: 2, 3 or 4 diameter collars, mounted on top of the unit c/w flexible hose. POWER CORD: 8 long electrical power cord. Page 2
3 FILTER SEQUENCES: General Purpose Filter Sequence 12 Filter Section Filter #1 Multi layer disposable polypad (Quatro PN: F ) Filter #2 2 pleated pre-filter (Quatro PN: F071) Filter # % HEPA Filter (Quatro PN: F074) Filter #4: Activated carbon chemical 8 filter module ( Quatro PN: AG097) 6 Filter Section Filter #1 Multi layer disposable polypad (Quatro PN: F ) Filter #2 2 pleated pre-filter (Quatro PN: F071) Filter # % HEPA Filter (Quatro PN: F074) Filter #4: 2 Activated carbon chemical filter module ( Quatro PN: AG072) Filter Sequence for dust only applications Filter #1 4 pleated 90% ASHRAE rated pre-filter (Quatro PN: F164) Filter # % HEPA Filter (Quatro PN: F074) Filter Sequence for odor and gas phase only applications Filter #1 AG097 for 6 filter sections Filter #1 AG098 for 12 filter sections 4.1 UNIT SPECIFICATIONS Model SPH-400 Series Series (12 Filter Section) Dimensions: Height: 24 "(762mm) Length: 15" (381mm) Width: 12" (304mm) Model SPH-400 Series Series (6 Filter Section) Dimensions: Height: 18 "(457mm) Length: 15" (381mm) Width: 12" (304mm) Voltage / Current: max. 120/1/60 North American 12.3 amps, 230/1/50 European 8.2 amps Approximate Weight: 70 lbs.(32kg) Page 3
4 UNIT RECEIVING INSTRUCTIONS 5.1 UNIT INSPECTION Upon receipt, inspect unit for either visible or concealed damage. Damage should be immediately reported to transport company. Remove unit from its box. Shipped inside the box are top cover, c/w collars and hose inside the unit. PRE START-UP Filter Installation 1) Ensure that you have received all necessary filters 2) Upon removing the unit from its box, ensure the unit is standing on its wheels; 3) Ensure that blue gel has remained in track during transport ( If not please contact factory) 4) Remove plastic wrapping from AG097 chemical filter (individually packaged). Use the handles on the chemical filters to lower carefully into the unit. 5) Lower the filters into the unit in the following order: General Purpose 12 Filter Section a. AG097 (8 chemical tray) ensuring that the perimeter rests in the Gel or on the gasket b. F074 HEPA filter (gasket side down) c. F071 pre-filter holding frame d. F071 disposable pleated filter e. F multi layered pad 6 Filter Section f. AG072 (2 chemical tray) ensuring that the perimeter rests on the gasket g. F074 HEPA filter (gasket side down) h. F071 pre-filter holding frame i. F071 disposable pleated filter j. F multi layered pad Filter Sequence for dust only applications 1) % HEPA Filter (Quatro PN: F074) 2) 4 pleated 90% ASHRAE rated pre-filter (Quatro PN: F164) 3) F multi layered pad Filter Sequence for odor and gas phase only applications a) Filter #1 AG097 for 6 filter sections a) Filter #1 AG098 for 12 filter sections 1) Replace the Top Plate (ensure buckles on the unit match tabs on the Top Plate) and fasten top of the unit; adjusting latches as necessary to create a tight fit. 2) Plug unit into an appropriate grounded receptacle and turn unit ON 3) If unit is equipped with a remote system interlock ensure that the switch is in the auto position and that the 12VDC or 24 VDC interlock power is connected 4) When using an optional 9 pin Sub D connector interlock, the control voltage will be wired to Pin # 3 and Pin #4. With optional pressure/vacuum switches pins 5 & 6 can be used to carry a 12 VDC or 24 VDC control signal Page 4
5 Speed Control ON / OFF switch Pre-Filter Pad, PN: F Dust Filter, PN: F071 F071 pre-filter holding frame Power Source HEPA FIlter, PN: F074 Odor Filter, PN: AG097 Standard Control Panel General purpose filter sequence START-UP 1) Plug in the appropriate power for your SPH unit; 2) Connect hose to the unit 3) Ensure all filters are installed 4) Turn switch on SERVICE NOTE: It is important to change the filters when required to avoid the excess build up of pressure within the unit that will result in diminished airflow and ultimately poorer filtration performance. The pre-filters should be changed on a routine interval. WARNING: DO NOT OPERATE SPH UNIT UNLESS ALL FILTERS ARE IN PLACE. 7.0 BLOWER MAINTENANCE PROCEDURES DISCONNECT POWER PRIOR TO ACCESSING TOP LID OR MOTOR SECTION BELOW To access blower section, do the following: 1) Switch unit off and unplug power cord before servicing the blower; 2) Unlatch and remove top cover 3) Remove all filters ; 4) Turn unit upside down; 5) With a Phillips screwdriver, remove (4) screws at the base of unit and holding the casters, lift off base You should now see the blower plate ( either 1,2 or 3 blowers depending on model) Page 5
6 Blower access caster plate View of blowers once caster plate is removed BRUSH REPLACEMENT (Disregard this section for BRUSHLESS Units) SERVICE NOTE: Please note that if your system is equipped with carbon brushes they need to be replaced approximately every 500 hours of operation. The brushes should be replaced before they are completely worn. Waiting until the brushes are completely expired could result in motor damage. Periodic brush inspection is a good preventative maintenance practice. The brushes on the SPH system can be changed in less than 5 minutes with the use of a screwdriver BLOWER MAINTENANCE, CHANGING BRUSHES WARNING: Switch unit off and unplug power cord from wall before servicing the blower. Screws Figure 1 Figure 2 Figure 3 1) Using a phillips screwdriver, unscrew the 2 screws holding down each of 2 gold colored brush casings (see Figure 1) 2) Lift gold colored tab and lift/pull out each brush (Figure 2 shows right brush removed) 3) Replace each brush onto turbine motor, screwing down the phillips screws over tab. YOU DO NOT HAVE TO REMOVE TURBINE FROM UNIT TO CHANGE BRUSHES! To access motor, remove blower section door. TURBINE & BRUSHES are visible once door is removed. Page 6
7 7.2 REPLACEMENT OF MOTOR PLATE (C/W1,2 BLOWERS) QUATRO To remove the entire plate c/w blowers: Switch unit off and unplug power cord before servicing the blower 1) loosen the motor wire forks from the terminal strips and loosen ground wire 2) loosen 4 wing-nuts at the 4 corners of the plate 3) lift off plate carefully, avoiding control panel 4) replace with new plate 2 Blower Plate Assy 8.0 FILTER REPLACEMENT PROCEDURE. 1) DISCONNECT POWER BEFORE ACCESSING TOP PLATE. 2) To replace appropriate filter, remove 2 flexible hose and unclamp 2 clamps as shown below; 3) Remove top lid and pull filters out of the unit; Filter Access Clamp, PN: H233 Pre-Filter Access Door For Upflow units Disposal of both odor and particulate filters is the responsibility of the enduser. Please contact local authorities for proper and legal disposal of spent filters. Page 7
8 General Dust Only Odor Only Purpose Application Application 6 Section 12 Section Filters are placed with #1 at the top: and # 4 at the bottom of the unit Filter #1: Pre-Filter F F F Filter #2: Secondary Filter F071 F Filter #3: Main filter F074 F Filter #4: Chemical Filter AG097/AG AG098 Replacement Filters : Qtybox Description Quatro P/N: 12 Pre-Filter Pad F Pre-Filter F Hi Capacity Filter F164 1 HEPA Filter F General Chemical Filter AG General Chemical Filter* AG General Chemical Filter* AG098 1 Brush Kit (4 brushes & 2 discharge pads) 120/1/60 AB011 * General purpose modules are filled with F100 media. * Modules containing special blends for specific applications will have different part # s 10.0 ANNUAL GENERAL INSPECTION The sealing integrity of the SPH-400 Series is essential. Every 12 months (during a filter change-out): 1) Verify sealing integrity of the chemical filter at the bottom of filter section (Gasket PN: H296 or Blue Gel) 2) Verify that the blue gel is in tact and providing a good filter seal 3) gasket under top cover plate (Gasket PN: H006). Page 8
9 11.0 OPERATION The air is drawn into the unit through the intake hose located at the top of unit. The air then passes through the various stages of particulate and odor / gas filtration. Powered by a motor/blower assembly, the clean air is then released through the bottom discharge grille into the floor of the room POSITIONING OF UNIT SPH should be placed as close as possible to debris generating machine REDUCTION IN AIRFLOW As the unit cleans the air, the filters are removing the particles of dust and debris in the air stream. As the filters accumulate debris (both visible and microscopic), a restriction on the blower/motor is created. As the restriction becomes greater, the air capacity delivered by the blower decreases rendering the unit less effective. Service Note: IT IS VERY IMPORTANT TO CHANGE PARTICULATE FILTERS ON A REGULAR BASIS TO AVOID DAMAGE TO MOTORS CAUSED BY LACK OF AIRFLOW AND OVERHEATING TROUBLESHOOTING GUIDE Symptoms Possible Cause Suggested Solution Unit will not start o Faulty Power supply o Return or supply grille blocked o Blown fuse o Unit not plugged into receptacle o Check power supply o Remove obstruction o Replace fuse (PN: E106) o Plug unit in Excessive noise o Blower wheel out of align o Replace blower High Amp Draw Insufficient airflow o Lack of restriction o Obstruction in system o Clogged filters o Ensure hose is attached from SPH equipment o Ensure filters are installed properly o Supply only Quatro replacement filters o Remove obstruction o Replace filters Excessive airflow O Filters not in place o Install filters Odor breaking through system Blue Gel is damaged O Chemical filter not sitting in blue gel O Chemical filters are consumed O Removing/Installing the chemical module excessively O Realign module so that the bottom is sealed in the gel O Replace chemical media Filters not in place O Scrape gel out of track and replace with new gel or a dense closed cell neoprene gasket 12.0 WARRANTY QUATRO Air Technologies warrants its equipment to be free from defect in material and workmanship under normal use and service for a period of one year from date of shipment. QUATRO's obligation under this warranty shall be limited to replacing any parts, thereof, which shall be demonstrated to have been defective. This is expressly in lieu of all other warranties, express or implied, including the warranties of merchantability and fitness. QUATRO claims no warranty as to merchantability or as to the fitness of the merchandise for any particular use and shall not be liable for any loss or damage. No person, firm or corporation is authorized to assume for QUATRO any other liability in connection with the sale of these goods. Equipment, parts and material manufactured by others and incorporated in QUATRO's equipment are warranted by QUATRO only to the extent of the original manufacturer's liability to QUATRO Air Technologies Inc.Conditions and Limitations: This warranty does not cover abuse, misuse, maintenance negligence, improper assembly, acts of vandalism, acts of God, general wear and tear, modifications of the equipment or installation of a part not recommended by QUATRO Air Technologies, as well as operation of the equipment at voltages other than those specified by QUATRO Page 9
10 13.0 Additional SPARE PARTS QUATRO Consumables: Minor Components Qty/unit Description Quatro P/N: 1 Toggle switch E110 1 Fuse E vDC Interface Switch E104 4 Blower plate Isolators H307 4 Casters H dia. Flexible hose H dia. Flexible hose H155 1 Blower Isolation Gasket H roll Filter Gasket H296/37ft 1 roll Filter Access Plate Gasket H006/50ft 2) Optional items 1) Sub D 9 pin connector can be incorporated to communicate with a manufacturers system. Standard wiring is as follows but customized pin in/ pin out arrangements may be used. Pin # VDC input Relay. Pin#4.. VDC Input Pin # VDC Vacuum Switch Pin # VDC 2) Vacuum Switch can be used to monitor the pressure of the entire system. The pressure switch is adjustable by turning the set screw. Clockwise rotation will lower the set point value Counter-clockwise rotation will increase the set point value For Technical Assistance, call QUATRO Air Technologies inc. at (514) (in Montreal Canada). Please ensure that you have your equipment serial number available when calling (located next to the power cord). Page 10
Operations & Maintenance Manual DFH-1000 DUCTLESS FUME HOOD
Operations & Maintenance Manual DFH-1000 DUCTLESS FUME HOOD ----------------------------------------------------------------We Make Clean Air----------------------------------------------------------------
More informationSPH-400 i Series General Manual
Operations & Maintenance Manual SPH-400 i Series General Manual Models: SPH-425, SPH-426, SPH-4B5, SPH-4BU5, SPH-4B6 with i Series contols. ------------------------------------------------------------------------Engineering
More informationI-6500 Series. Industrial Applications. Operations & Maintenance Manual. Air Purifiers for. Manufactured. Serial number.
F. 8.88.29 Air Purifiers for Industrial Applications AirRhino 000 Hood 80 lbs of carbon AirRhino 2000 VS 00 lbs of carbon I-00 Series AirArmor custom Operations & Maintenance Manual SSU custom Manufactured.0
More informationivac TWIN Premium Turbine Dust Collectors
Operations & Maintenance Manual ivac ivac TWIN Premium Turbine Dust Collectors --------------------------------------------------------------------------------------------------------------------------------------
More informationZENOTEC Air + Instructions for Use. ivt (120 volt) & ivt25-912(230 volt)
ZENOTEC Air + Instructions for Use ivt16-912 (120 volt) & ivt25-912(230 volt) 1- INTRODUCTION You are now the owner of a Quatro IVac System, an advanced effective indoor air purification system designed
More informationquatroair.com AIR TECHNOLOGIES INC.
quatroair.com AIR TECHNOLOGIES INC. LaserBlue Gel Zero Filter Bypass. Guaranteed! Designed to meet the most stringent cleanroom requirements, the LaserBlue gel forms an impenetrable barrier against the
More informationX-3400A, X-3500, X-3700 OWNER S MANUAL PLEASE READ AND SAVE THESE INSTRUCTIONS
X-3400A, X-3500, X-3700 OWNER S MANUAL XPOWER MANUFACTURE, INC. 220 Clary Avenue San Gabriel, CA 91776, USA Tel: 626-285-3301, Fax: 626-285-330 PLEASE READ AND SAVE THESE INSTRUCTIONS 1 Index Introduction...2
More informationBlue Air. Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases
Blue Air Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases Please read this manual completely before installing or operating this unit! BACB53 BACB71 BACB74 BACB83 BACB86 BACB96
More informationQuest DRY 150. Quest PowerHEPA 500. quest. Read and Save These Instructions. Quest PowerHEPA 500:
Quest DRY 150 Quest PowerHEPA 500 Read and Save These Instructions This manual is provided to acquaint you with the air scrubber so that installation, operation and maintenance can proceed successfully.
More informationFurther information: Berriman Associates Model 850P.2 Owners Manual
Model 850P.2 Owners Manual Thank you for purchasing the Model 850P.2 medical grade air purification system (APS), one of the finest air cleaning devices in the world. In order to ensure optimizing the
More informationInstallation & Operation Manual Chef Base
Installation & Operation Manual Chef Base Please read this manual completely before installing or operating this unit! BACB53 BACB53M BACB71 BACB71M BACB74 BACB74M BACB83 BACB83M BACB86 BACB86M BACB96
More informationREAD AND SAVE THESE INSTRUCTIONS. Air Boss MP600M Vertical Air Flow Mist Precipitator Industrial Applications. TRION
READ AND SAVE THESE INSTRUCTIONS Vertical Air Flow Mist Precipitator Industrial Applications TRION Vertical Air Flow Mist Precipitator for Industrial Applications Table of Contents Design...2 Installation...2
More informationARM-EVAC 50. Benchtop Plenum/Arm Extractor MANUAL NO REV. B
ARM-EVAC 50 Benchtop Plenum/Arm Extractor MANUAL NO. 8881-0980 REV. B TABLE OF CONTENTS Safety. 3 Introduction 4 Specification.. 4 Features. 5 Set-Up. 6 Operation 7 Maintenance.. 7 Troubleshooting.. 8
More informationReach ins, Freeezers & Refrigerators Installation & Operation Manual
Reach ins, Freeezers & Refrigerators Installation & Operation Manual BSR23 BSF23 BSR49 BSF49 BSR72 BSF72 IMPORTANT SAFETY INSTRUCTIONS (SAVE THESE INSTRUCTIONS) Visit us on the web at www.blueairinc.com
More informationMiracle State Of The Art Air Filtration System!
I N D O O R A I R Q U A L I T Y S O L U T I O N S Miracle State Of The Art Air Filtration System! High efficiency particulate (HEPA) filter combined with optimized sorbent media provides the ultimate solution
More informationBlue Air. Commercial Refrigeration Inc. Installation & Operation Manual Glass Door Countertop Refrigerator
Blue Air Commercial Refrigeration Inc. Installation & Operation Manual Glass Door Countertop Refrigerator Please read this manual completely before installing or operating this unit! BAGR7 Blue Air reserves
More informationMODEL FA1 Mini Air Filtration System. Operations Manual
MODEL FA1 Mini Air Filtration System Operations Manual READ AND SAVE THESE INSTRUCTIONS WARNING: Disconnect from power supply before performing maintenance procedures such as cabinet cleaning, changing
More informationNilfisk-CFM SS Vapor Vacuum Instructions for Use and Spare Parts Manual
Nilfisk-CFM SS Vapor Vacuum Instructions for Use and Spare Parts Manual Caution: This Nilfisk-CFM vacuum cleaner is not to be used in explosion hazardous areas as serious injury could result. Your new
More informationUser s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.
User s Guide Oreck Air Purifier with HEPA Filtration Important! Read this manual carefully, and keep for future reference. Enjoy Congratulations on your purchase of the Oreck Air Purifier with HEPA Filtration.
More informationQuest H5. Quest Dry. Read and Save These Instructions. Installation, Operation and Maintenance Instructions. Quest H5:
Quest Dry Quest H5 Read and Save These Instructions This manual is provided to acquaint you with the Quest H5 air mover so that installation, operation and maintenance can proceed successfully. Ultimate
More informationRK Standby Battery Operator s Manual
49-8104RK Standby Battery Operator s Manual Part Number: 71-0118RK Revision: C Released: 8/4/17 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment sold by us to
More informationOwner s Manual Phoenix Guardian HEPA System
4201 Lien Rd Madison, WI 53704 Owner s Manual Phoenix Guardian HEPA System Installation, Operation & Service Instructions Read and Save These Instructions The Phoenix Guardian HEPA System remains the first
More informationOwner s Manual Phoenix Guardian HEPA System
PO Box 8680 Madison, WI 53708 Phoenix Guardian HEPA System TS-265A Owner s Manual Phoenix Guardian HEPA System Installation, Operation & Service Instructions Read and Save These Instructions The Phoenix
More informationDESKTOP CONTAINMENT SYSTEM
AIR TECHNOLOGIES INC. BRATIN LE OF EX CE G CE Solder and Waxing Fumes Conformal Coating Vapors Reflow Oven Exhaust Wave Soldering Exhaust Dedrossing Solvent Vapors Laser Cutting & Marking CELLE 1991-2
More informationFor ELECTRONIC INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS TO BE USED IN CONJUNCTION WITH: SERVICE GUIDE for Gage Unit
www.purafil.com FIRST IN CLEAN AIR SERVICE GUIDE For ELECTRONIC CABINET UNIT INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS TO BE USED IN CONJUNCTION WITH: SERVICE GUIDE for Gage Unit SERVICE GUIDE
More informationGETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL
GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL 2320 Lakecrest Drive, Pekin IL 61554 PH. (888) 747-4389 Fax (309) 495-0625 Website: www.getzequipment.com
More informationPremium Turbine Dust Collectors
ivac SlimLine ivac ivac TWIN 900 Series Premium Turbine Dust Collectors Instruction & Maintenance Manual READ AND UNDERSTAND THIS MANUAL BEFORE OPERATING THE SYSTEM STORE THE MANUAL IN A SAFE PLACE FOR
More informationFA1 Series Air Filtration System. Operations Manual
FA1 Series Air Filtration System Operations Manual READ AND SAVE THESE INSTRUCTIONS WARNING: Disconnect from power supply before performing maintenance procedures such as cabinet cleaning, changing filters
More informationSource Capture Air Purification System
Source Capture Air Purification System HA-SCP-G3 Owner s Manual Table of Contents HealthyAir HA-IFM-1111 Filter 1 Important Safety Instructions 2 Technical Specifications 3 Packaging Reference 4 Packing
More informationPHOENIX GUARDIAN H. E. P. A. SYSTEM
PHOENIX GUARDIAN H. E. P. A. SYSTEM Therma-Stor Products Box 8050 Madison, WI 53708 Toll Free 1-800-533-7533 Local 1-608-222-5301 PHOENIX GUARDIAN Operation & Service Instructions Table of Contents 1.
More informationOWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS
OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS IMPORTANT SAFETY INSTRUCTIONS When installing and using this electrical equipment, basic safety precautions should always be followed, including
More informationUser s Manual and Operating Instructions
User s Manual and Operating Instructions Model Numbers: CL-36-BDF-A, CL-42-BDF-A, CL-48-BDF-A E355088 READ AND SAVE THESE INSTRUCTIONS IMPORTANT: Read and understand all of the instructions in this manual
More informationMODEL 950C-NP-UV Installation and Owners Manual
MODEL 950C-NP-UV Installation and Owners Manual Further Information: BERRIMAN ASSOCIATES 1-800-480-3630 www.berriman.com Thank you for purchasing the MODEL 950-C-NP-UV medical grade air purification system
More informationPHOENIX MINI-GUARDIAN
PHOENIX MINI-GUARDIAN H. E. P. A. SYSTEM Therma-Stor Products A Division of DEC International Box 8050 Madison, WI 53708 Toll Free 1-800-533-7533 Local 1-608-222-5301 Table of Contents PHOENIX MINI-GUARDIAN
More informationMODEL FA5 Air Filtration System. Operations Manual
MODEL FA5 Air Filtration System Operations Manual READ AND SAVE THESE INSTRUCTIONS WARNING: Disconnect from power supply before performing maintenance procedures such as cabinet cleaning, changing filters
More informationRK Standby Battery Operator s Manual
49-8103RK Standby Battery Operator s Manual Part Number: 71-0117RK Revision: 0 Released: 8/18/08 www.rkiinstruments.com Product Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to
More informationOwner s Manual Phoenix GuardianR
4201 Lien Rd Madison, WI 53704 Owner s Manual Phoenix GuardianR Installation, Operation & Service Instructions Read and Save These Instructions The Phoenix GuardianR HEPA System is the most compact, portable
More informationOwner s manual for installation, usage and maintenance
Owner s manual for installation, usage and maintenance AQC Dust Collecting Systems This manual is the property of the buyer. It is to be left with the unit after the installation and start-up. A. Q. C.
More informationAir Filtration and Mist Collection System for Machine Coolants Patent Pending Installation and Operating Instructions Model #MM-700 Manufactured by: Industrial Tool 14 Industrial Park Rd. Troy, NY 12180
More informationGETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL
GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL 2320 Lakecrest Drive, Pekin, Illinois 61554 Telephone: 888-747-4389 Fax: 309-495-0625 Website: www.getzequipment.com
More informationModel G14SD Vapor Management System
Instruction Manual Model G14SD Vapor Management System (For Models: DSD and SSD 110/115v) Manufactured in USA for Medivators Reprocessing Systems by: PCI Medical Inc. 12 Bridge Street, PO Box 188 Deep
More informationROLLER GRILL Instruction Manual Model #8223, 8224, Part No Revised:March 2008
ROLLER GRILL Instruction Manual Model #8223, 8224, 8225 Part No. 88189 Revised:March 2008 Safety Precautions Models #8223, 2 #8224, #8225 FORWARD This manual covers the model # 8223, # 8223, 8225 ROLLER
More informationOWNER S MANUAL C O M M E R C I A L I N D O O R A I R Q U A L I T Y S O L U T I O N S. Total High Efficiency Particulate & Gaseous Filtration System
OWNER S MANUAL C O M M E R C I A L I N D O O R A I R Q U A L I T Y S O L U T I O N S Ever Total High Efficiency Particulate & Gaseous Filtration System State-of-the-art air cleaner is the ultimate solution
More informationLoctite Air Filtration System Part Number EQUIPMENT. Operation Manual
Loctite Air Filtration System Part Number 98276 EQUIPMENT Operation Manual Contents Page No. 1 PLEASE OBSERVE THE FOLLOWING................................... 1-2 1.1 EMPHASIZED SECTIONS...............................................
More informationCLEAN AIR WORKSTATION REVERSE FLOW. Installation and Operations Manual
CLEAN AIR WORKSTATION REVERSE FLOW Installation and Operations Manual CLEAN AIR WORKSTATION REVERSE FLOW Installation and Operations Manual Revision: 16-Jan-17 Page 1 of 12 CLEAN AIR WORKSTATION REVERSE
More informationOperating Manual PFB-2500
Operating Manual PFB-2500 Portable Filtration Module Part Number FM03 Master Contract No. 215873 Certificate No. 2449861 Class 3812-81 Fans and Blowers Class 3812-01 Fans and Blowers 860.445.0334 888.637.7779
More informationOwner s Manual Phoenix Mini-Guardian HEPA System
4201 Lien Rd Madison, WI 53704 Owner s Manual Phoenix Mini-Guardian HEPA System Installation, Operation & Service Instructions Read and Save These Instructions The Phoenix Mini-Guardian HEPA System is
More informationFAN POWERED HEPA FILTER UNIT
READ COMPLETELY AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE FAN POWERED HEPA FILTER UNIT (MOTOR ACCESSIBLE) SSLFHFD-FP-MA INSTALLATION AND SERVICE MANUAL 2 Critical operation conditions of the Fan
More informationOmniaire 1000V Instruction Manual-8/05
The OMNIAIRE 1000V HEPA Air Filtration system is a variable speed HEPAfiltered negative air machine designed for removal of toxic mold, asbestos or other airborne contaminants during construction, renovation
More informationHarvil 5 Foot Air Hockey Table
ASSEMBLY INSTRUCTIONS Harvil 5 Foot Air Hockey Table Thank you for your purchase of this Harvil product! We work around the clock and around the globe to ensure that Harvil products maintain the highest
More information24 Linear Actuator 115 Volts A.C. (Cat. # C430A)
Installation, Operation & Parts Manual Read carefully the information provided. Retain manual for future reference. 24 Linear Actuator 115 Volts A.C. (Cat. # C430A) Page 1 of 8 IS10007.doc 11/15/06 IMPORTANT!
More informationEXT DUCTLESS FUME HOOD
EXT DUCTLESS FUME HOOD POLYPROPYLENE Installation and Operations Manual EXT DUCTLESS FUME HOOD Installation and Operations Manual Revision: 1-Feb-16 Page 2 of 12 EXT DUCTLESS FUME HOOD Installation and
More informationMODEL MA4210 Installation and Operation Manual Important:
MODEL MA4210 Installation and Operation Manual Important: This manual contains specific cautionary statements relative to worker safety. Read this manual thoroughly and follow as directed. It is impossible
More informationARM-EVAC 105. Central Filter Unit
ARM-EVAC 105 Central Filter Unit MANUAL NO. 8881-0990 REV. A (110v Systems only) TABLE OF CONTENTS Safety. 3 Introduction 4 Specification.. 4 Features. 5 Set-Up. 5 Operation 6 Maintenance.. 6 Troubleshooting..
More information2SHE Series Direct-Drive Shutter Fans
Operational Instruction and Parts Manual Item #: 481810 Rev Date: 101414 2SHE Series Direct-Drive Shutter Fans Fantech, Inc. and Systemair Mfg. certify that the ventilators shown herein are licensed to
More informationTXH TOTAL EXHAUST HOOD. Installation and Operations Manual
TXH TOTAL EXHAUST HOOD Installation and Operations Manual TXH TOTAL EXHAUST HOOD Installation and Operations Manual Revision: 25-Nov-16 Page 2 of 12 TXH TOTAL EXHAUST HOOD Installation and Operations Manual
More informationINSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS. Part Number: P DM
INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS Whole House Duct-Mount HEPA Air Cleaner Part Number: P102-400DM TABLE OF CONTENTS Page SAFETY CONSIDERATIONS...1 INTRODUCTION...1,2 INSTALLATION...2,3
More informationMODEL GS1-100 Air Filtration System. Operations Manual
MODEL GS1-100 Air Filtration System Operations Manual READ AND SAVE THESE INSTRUCTIONS ARNING: Disconnect from power supply before performing maintenance procedures such as cabinet cleaning, changing filters
More informationRaydot LLC 24 Actuator (115 VOLT)
Installation, Operation & Parts Manual Read carefully the information provided. Retain manual for future reference. Raydot LLC 24 Actuator (115 VOLT) 145 Jackson Ave. S. Cokato, MN 55321-USA (320) 286-2103
More informationDESIGN-AIRE SL-RSR-EC. Installation and Operations Manual
DESIGN-AIRE SL-RSR-EC Installation and Operations Manual DESIGN-AIRE SL-RSR-EC Installation and Operations Manual Revision: 28-Jan-16 Page 2 of 15 DESIGN-AIRE SL-RSR-EC Installation and Operations Manual
More informationDESIGN-AIRE SL-RSR-EC. Installation and Operations Manual
DESIGN-AIRE SL-RSR-EC Installation and Operations Manual DESIGN-AIRE SL-RSR-EC Installation and Operations Manual Revision: 06-Feb-17 Page 2 of 15 DESIGN-AIRE SL-RSR-EC Installation and Operations Manual
More informationOperating Manual MAC-21 VFD
Operating Manual MAC-21 VFD Portable Filtration Module Part Number FM37VFD Master Contract No. 215873 Certificate No. 2449861 Class 3812-81 Fans and Blowers Class 3812-01 Fans and Blowers 860.445.0334
More informationPart No DROP IN POPCORN WARMERS Instruction Manual Model #2343, 2344, 2345
Part No. 39406 DROP IN POPCORN WARMERS Instruction Manual Model #2343, 2344, 2345 SAFETY PRECAUTIONS 2 INSTALLATION INSTRUCTIONS Inspection of Shipment: Unpack all cartons and check thoroughly for any
More informationMAVERICK 7' POOL TABLE WITH TABLE TENNIS ASSEMBLY INSTRUCTIONS
MAVERICK 7' POOL TABLE WITH ASSEMBLY INSTRUCTIONS NG1023 THANK YOU! Thank you for purchasing this product. We work around the clock and around the globe to ensure that our products maintain the highest
More informationMLS KICK-OFF TABLETOP SOCCER TABLE ASSEMBLY INSTRUCTIONS
MLS KICK-OFF TABLETOP SOCCER TABLE ASSEMBLY INSTRUCTIONS NGD1028 1 THANK YOU! Thank you for your purchase of this Harvil product. We work around the clock and around the globe to ensure that Harvil products
More informationOperator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:
Storage System Ultrasound Probe Cabinet Operator's Manual Manufactured by: CIVCO Medical Solutions 102 First Street South Kalona, IA 52247 USA 319.248.6757 / 800.445.6741 WWW.CIVCO.COM Copyright 2018 All
More informationAUTO-BREEZE Cotton Candy Machine Instruction Manual Model #3052
Part No. 55147 Revised: August 2004 AUTO-BREEZE Cotton Candy Machine Instruction Manual Cincinnati, OH 45241-4807 USA Safety Precautions Auto-Breeze 2 INTRODUCTION Your Floss Machine warranty is described
More informationRENEGADE SLATE BUMPER POOL TABLE ASSEMBLY INSTRUCTIONS
RENEGADE SLATE BUMPER POOL TABLE ASSEMBLY INSTRUCTIONS NG2404PG THANK YOU! Thank you for purchasing this product. We work around the clock and around the globe to ensure that our products maintain the
More informationHarvil 4 Foot Air Hockey Table
Harvil 4 Foot Air Hockey Table Thank you for your purchase of this Harvil product! We work around the clock and around the globe to ensure that Harvil products maintain the highest possible quality. However,
More informationEnvironmental Series Air Curtains
INSTALLATION & OPERATING INSTRUCTIONS & PARTS MANUAL FOR ALL 120 and 230 VOLT 1/4, 1/2 AND 3/4 H.P. MOTOR MODELS Environmental Series Air Curtains READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL,
More informationAiristar 100GT Owner s Manual Airistar 100GT Air Purifier
Airistar 100GT Owner s Manual 2007 Airistar 100GT Air Purifier 100 GT Check power switches. Both the green on-off switch and the speed control knob must be in the on position. Check that the unit is connected
More informationTest Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com BVX-100. Fume Extraction System _B
Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com BVX-100 Fume Extraction System 7100-0070_B SYSTEM OVERVIEW BVX-100 System 1. Plenum (the open portion
More informationHURRICANE 54-IN FOOSBALL TABLE ASSEMBLY INSTRUCTIONS
HURRICANE 54-IN FOOSBALL TABLE ASSEMBLY INSTRUCTIONS Please Do Not Hesitate to Contact Our Consumer Hotline at 800-759-0977 with Any Questions That May Arise During Assembly or Use of This Product! NG1033F
More informationHUSTLER 7' & 8' POOL TABLE ASSEMBLY INSTRUCTIONS
HUSTLER 7' & 8' POOL TABLE ASSEMBLY INSTRUCTIONS NG2515PB/NG2520PB THANK YOU! Thank you for purchasing this product. We work around the clock and around the globe to ensure that our products maintain the
More informationPLAYOFF 48" FOOSBALL TABLE ASSEMBLY INSTRUCTIONS
PLAYOFF 48" FOOSBALL TABLE ASSEMBLY INSTRUCTIONS NG1031F THANK YOU! Thank you for purchasing this product. We work around the clock and around the globe to ensure that our products maintain the highest
More information9' & 12' CHALLENGER SHUFFLEBOARD TABLE ASSEMBLY INSTRUCTIONS
9' & 12' CHALLENGER SHUFFLEBOARD TABLE ASSEMBLY INSTRUCTIONS NG1205 / NG1210 / NG1212 / NG1214 THANK YOU! Thank you for purchasing this product. We work around the clock and around the globe to ensure
More informationARM-EVAC 500 Central Filter Unit
ARM-EVAC 500 Central Filter Unit MANUAL NO. 8881-0500 REV. C TABLE OF CONTENTS Introduction... 3 Specification. 4 Safety.... 5 Filter Cartridge Notes 6 Set-Up. 7 Set-Up (continued).. 8 Self Calibration
More informationPortable Air Purifiers
O 0 FLTER 0 HEPA FLTER Portable Air Purifiers READ AND SAVE THESE NSTRUCTONS NSTALL PRE-FLTER BEFORE USE PRE-FLTER PRE-FLTER Distributed by: PREFLTER HEPA PREFLTER T M 0 HEPA FLTER PREFLTER.c om (888)
More informationFor BLOWER INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS
www.purafil.com FIRST IN CLEAN AIR SERVICE GUIDE For BLOWER ASSEMBLY INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS Purafil, Inc. 2654 Weaver Way, Doraville, Georgia, 30340, U.S.A. www.purafil.com
More informationAdjustable Angled Incline Conveyor Owners Manual with Operating Instructions
Adjustable Angled Incline Conveyor Owners Manual with Operating Instructions Revision 012211 Table of Contents Basic Conveyor Features 3 Getting Started 4 Setting Up the Incline Conveyor 5 Belt Removal
More informationESE Series Cast Iron Sewage Pumps
Owner s Manual ESE Series Cast Iron Sewage Pumps TABLE OF CONTENTS General Safety.................... 2 Specifications..................... 3 Installation.................... 4 & 5 Troubleshooting...................
More informationInstallation & Operation Manual PWS1000R Rack Mount Power Supply
Installation & Operation Manual PWS1000R Rack Mount Power Supply 8128 River Way, Delta B.C. V4G 1K5 Canada T. 604.946.9981 F. 604.946.9983 TF. 1.800.668.3884 (US/CANADA) www.analyticsystems.com Copyright
More informationInstruction Sheet SRSR SERIES. Rotating Sliding Rail System
Instruction Sheet SRSR SERIES Rotating Sliding Rail System THANK YOU Thank you for purchasing the SRSR Series Rotating Sliding Rail System. Please read these instructions thoroughly before assembling this
More information!"" #$% "!&' ( ( ) *
!"" #$% "!&' (( ) * FunPop Assembly Manual Model # 2649CR Part No. 59406CR Revised: October 2004 Cincinnati, OH 45241-4807 USA INSTALLATION INSTRUCTIONS Checking Shipment Unpack carton and check thoroughly
More informationOperation Manual for ARM-EVAC 150 Fume Extraction System
Operation Manual for ARM-EVAC 150 Fume Extraction System MANUAL P/N 5050-0593 REV. 11 Nov 2018 This manual applies to: Model Required Power Part Number ARM-EVAC 150 120 VAC 8889-0150-P1 ARM-EVAC 150 230
More informationSIDEKICK TABLETOP SOCCER ASSEMBLY INSTRUCTIONS
SIDEKICK TABLETOP SOCCER ASSEMBLY INSTRUCTIONS NG1028T3 THANK YOU! Thank you for purchasing this product. We work around the clock and around the globe to ensure that our products maintain the highest
More informationAUTOMATIC SUBMERSIBLE UTILITY PUMP
AUTOMATIC SUBMERSIBLE UTILITY PUMP Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #1043-0006 Español p. 9 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems,
More informationMAGNETOGRAPHIC PRINTER
MAGNETOGRAPHIC PRINTER DF Argos Web Cleaning Station Document release : Rev0 Oct 2010 Creation. Rev1 Nov 2012 Update NIPSON Technology SAS 12, avenue des Trois Chênes - Techn hom 3-90000 Belfort - France
More informationEXT HEPA/CARBON FUME HOOD
EXT HEPA/CARBON FUME HOOD POLYPROPYLENE Installation and Operations Manual EXT HEPA/CARBON FUME HOOD Installation and Operations Manual Revision: 28-Jun-18 Page 2 of 12 EXT HEPA/CARBON FUME HOOD Installation
More informationThe BVX-100 Fume Extraction System
The BVX-100 Fume Extraction System USER GUIDE FUME REMOVAL SYSTEMS Copyright 2000, All Rights Reserved 7100-0070 Rev. A BVX-100 USER GUIDE System Overview... 2 System Set Up and Operation... 3 Filtration...
More informationCOMPRESSED AIR LOADER MODEL: AL-1
COMPRESSED AIR LOADER MODEL: AL-1 Document: AL-1 IM 10-22-2011 TABLE OF CONTENTS Important Notices and Precautions 3 Quick Installation 4 Product Description 4 Principle of Operation 5 Unpacking and Inspection
More informationInstallation & Service Manual for Portable Fume Collector. Model PFC-800
Installation & Service Manual for Portable Fume Collecr Model PFC-800 August 3, 2009 Portable Fume Collecr Table of Contents Disclaimer...3 Uncrating...4 Description & Operation...4 Optional Equipment...4
More informationModel 616 Rotating Disk Electrode Instruction Manual
Model 616 Rotating Disk Electrode Instruction Manual 219303 C / 1202 Printed in USA Advanced Measurement Technology, Inc. a/k/a Princeton Applied Research, a subsidiary of AMETEK, Inc. WARRANTY Princeton
More informationHenny Penny Rotisserie Display Model SCD-6/8 TECHNICAL MANUAL
Henny Penny Rotisserie Display Model SCD-6/8 TECHNICAL MANUAL TABLE OF CONTENTS Section Page Section 1. TROUBLESHOOTING... 1-1 1-1. Introduction... 1-1 1-2. Safety... 1-1 1-3. Troubleshooting... 1-1 1-4.
More informationIMPORTANT SAFETY INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS WARNING: To Reduce the Risk of Fire, Electric Shock or Injury: Electric shock could occur if used on wet surfaces. DO NOT expose to rain. Store indoors. When using this vacuum
More informationINSTALLATION & OPERATION MANUAL
INSTALLATION & OPERATION MANUAL VTC180 DC/DC Converter An ISO9001 and AS9100 Registered Company Battery Chargers Inverters Power Supplies Voltage Converters 8128 River Way, Delta B.C. V4G 1K5 Canada T.
More informationMODEL MC1500 Installation and Operation Manual Important:
MODEL MC1500 Installation and Operation Manual Important: This manual contains specific cautionary statements relative to worker safety. Read this manual thoroughly and follow as directed. It is impossible
More informationHigh Velocity Series Air Curtains
INSTALLATION & OPERATING INSTRUCTIONS & PARTS MANUAL FOR ALL 208-230/480 VOLT 3 PHASE. MOTOR MODELS High Velocity Series Air Curtains READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE, OR
More informationMICRO-AIR AIR CLEANER INSTALLATION AND OPERATION MANUAL. MX3510 Includes Installation, Operation, and Service Instructions CAUTION
MICRO-AIR AIR CLEANER INSTALLATION AND OPERATION MANUAL MX3510 Includes Installation, Operation, and Service Instructions CAUTION Read complete instructions before operating. Please file for future reference.
More informationFD Conveyor for FD 260 Tabber
FD 260-20 Conveyor for FD 260 Tabber Operator Manual 1/2011 First Edition TABLE OF CONTENTS 1. INTRODUCTION... 1 1.1 FD 260-20 DESCRIPTION... 1 1.2 ITEMS INCLUDED... 1 1.3 OPERATING MANUAL SAFETY TERMS...
More information