Temposonics. Absolute, Non-Contact Position Sensors. MH Series. Temposonics MH 200. Technical Data / Description. Compact sensor for mobile hydraulics

Similar documents
Temposonics. Absolute, Non-Contact Position Sensors. MH Series. Temposonics MH Analog /Digital. Technical Data / Description

Temposonics. Absolute, Non-Contact Position Sensors. MH Series. Temposonics MB Analog. Technical Data / Description

Temposonics. M-Series Analog Redundant. Absolute, Non-Contact Positions Sensors. Temposonics MT Measuring length mm

Temposonics. M-Series Analogue / SIL2* Absolute, Non-Contact Position Sensors. Temposonics MH Measuring Length mm

Temposonics. M-Series PWM. Absolute, Non-Contact Position Sensors. Temposonics MH Measuring Length mm. Document Number Revision B

Temposonics. Magnetostrictive Linear Position Sensors. MH-Series MH5 Analog Data Sheet

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

Temposonics. MH-Series Analog Redundant. Absolute, Non-Contact Positions Sensors. Temposonics MT Measuring length mm

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

Temposonics. M-Series Analog. Absolute, Non-Contact Position Sensors. Temposonics MH Measuring length mm. Compact Sensor for Mobile Hydraulics

Temposonics. Magnetostrictive Linear Position Sensors. MHRM Analog Data Sheet. For embedded or externally threaded installation

Temposonics. M-Series Analog. Magnetostrictive Position Sensors. Temposonics MH Measuring length mm SENSORS

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

Temposonics. G-Series Analog Redundant. Magnetostrictive Position Sensors. Redundancy for enhanced safety

Temposonics. Magnetostrictive, Absolute, Non-contact Linear-Position Sensors. R-Series Models RP and RH DeviceNet Output.

R-Series Rod Model RS. Data Sheet. Model RS Rod-style sensor with IP68/IP69K Super Shield Housing. Interrogation Return wire.

Temposonics. Magnetostrictive Linear Position Sensors. MH-Series Flexible MH Installation Manual

Temposonics. R-Series DeviceNet. Magnetostrictive Position Sensors. Intelligent Design. Temposonics RP and RH Measuring length mm SENSORS

Temposonics. Magnetostrictive, Absolute, Non-contact Linear-Position Sensors. R-Series Models RP and RH Ethernet POWERLINK.

Temposonics. E-Series Analog + Start / Stop. Magnetostrictive Position Sensors. Temposonics EP Measuring range mm / mm SENSORS

Temposonics. Magnetostrictive Linear Position Sensors. DATA SHEET GBS Analog

Temposonics. Magnetostrictive Linear-Position Sensors. R-Series Model RP and RH Sensors Synchronous Serial Interface (SSI) Output D

Temposonics. G-Series Analog or Start/Stop. Absolute, Non-Contact Position Sensors. Temposonics GP and GH Stroke length mm depends on output

Temposonics. Magnetostrictive Linear Position Sensors. TH CANbus Data Sheet

ANALOG. PARAMETER SPECIFICATION Measured Variable: Displacement, Velocity (magnitude only) 16 bit or mm, whichever is greater

SSI. Synchronous Serial Interface

CANBUS G. Up to mm ( in.) < ± 0.01% of full stroke or ± 0.04 mm ( in.), whichever is greater*

Temposonics. Magnetostrictive Linear Position Sensors. TH Analog Data Sheet

Temposonics ATEX. Magnetostrictive Linear Position Sensors. DATA SHEET High Pressure Housing (HPH) The Measurable Difference

PRODUCT SELECTOR GUIDE

L E V E L P L U S M - S E R I E S ANALOG

Temposonics Magnetostrictive Linear-Position Sensors

PRODUCT SELECTOR GUIDE

Temposonics. Magnetostrictive Linear Position Sensors. TH Analog SIL 2 capable Data Sheet

Temposonics Magnetostrictive Linear Position Sensors. Temposonics GB-Series Brief Instructions

Part No Rev. E

Temposonics Magnetostrictive Linear Position Sensors. Temposonics E-Series Brief Instructions

Pressure transmitters for heavy-duty applications MBS 2000 and MBS 2050

Level Plus. Magnetostrictive Liquid Level Transmitters with Temposonics Technology. LP-Series SE Replacement Installation Manual

High temperature pressure transmitters for heavy-duty applications MBS 2200 and MBS 2250

Temposonics. Temposonics R-Series. Instruction Manual. EtherCAT Interface. Absolute, Non-Contact Position Sensors. Rod model Temposonics-RH

Temposonics. Magnetostrictive Linear Position Sensors. GB-Series Analog Operation Manual

Linear-Transducer LMP48 - A

Pressure transmitters for heavy duty applications MBS 3200 and 3250

Temposonics Absolute, Non-Contact Position Sensors

Temposonics. R-Serie Catalog. 0.5 μm. Absolute, Non-Contact Position Sensors. The Measurable Difference

Temposonics Absolute, Non-Contact Position Sensors

CD34CNFLFxxx. Capacitive sensor, Foreground Suppression. Main features. Main functions. Description

Pressure transmitter for general industrial purposes MBS 3000 and MBS 3050

Temposonics. Absolute, Non-Contact Position Sensors. OPERATION MANUAL R-Serie Analog. The Measurable Difference

GIB TECHNICAL DATA MECHANICAL DIMENSIONS SINGLE/DUAL AXIS ENTRY LEVEL TILT SENSOR (XY/Z) ENTRY LEVEL tilt sensor with MEMS technology.

Temposonics. R-Series Analog. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Measuring length mm

Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS Technical brochure

Pressure transmitter for general industrial purposes Type MBS 3000 and MBS 3050

Pressure transmitter for marine applications MBS 3100 and MBS 3150

Angle sensor AN2 series 30

TECHNICAL PAPER. Magnetostrictive Position Transducers in Medical Applications. David S. Nyce. Introduction

958A Compact Housing Linear Displacement Transducer

Pressure transmitters for heavy duty applications MBS 8200 and MBS 8250

Pressure Transmitter for wind turbine applications MBS 8200 and MBS 8250

Magnetostriction in Automotive Position Measurement

Automotive Sensor Products

Profibus-DP Output. Profibus-DP output: Standard Profibus-DP signal. Profibus Output

Pressure transmitter for general purpose Type MBS 1700 and MBS 1750

Temposonics. R-Series Analog. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Stroke length mm

ACTUATORS POSITION SENSOR

Electronic Pressure Switches

PROPORTIONAL VALVES. G1/4, G3/8 and G1/2 tapped body or subbase mounted body with digital pressure control

More Precision. mainsensor Magneto-inductive displacement sensor

Pressure transmitter for marine applications Type MBS 5100 and MBS 5150

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

0 to 100 up to 0 to PSI (gage) Packard Electric Metri-Pack 150 Series, M12-4 Pole* 1/4-18 NPT ma, VDC, 0-5 VDC, 0-10 VDC

Pressure transmitters for heavy duty applications Type MBS 3250

958A Compact. Series 958 Compact Housing LDT. Housing ABSOLUTE PROCESS CONTROL KNOW WHERE YOU ARE... REGARDLESS

Electronic Pressure Switches

Encoder WDGA 58V CAN SAE J1939

Rotary Sensor potentiometric Heavy-duty. Series IPX-7900

PRM7-04. Functional Description HA /2012. Proportional Directional Control Valves. Replaces HA /2009

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Standard cylinders DDPC, with measured-value transducer DADE

Temposonics. Magnetostrictive Linear Position Sensors. R-Series Profinet IO RT Operation Manual

PRM7-06. Functional Description HA /2006. Proportional Directional Control Valves. Replaces HA /2002

PRM7-06. Functional Description HA /2014. Proportional Directional Control Valves. Replaces HA /2013

Technical Data Measuring principle Thin-film-on-steel Media temperature -40 C C

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Pressure transmitter for industrial applications Type MBS 4510

G 1/4 A DIN 3852 (bar version) ±0.5 %FS max

DA 15 N 06 BLDC 250 DA 15 N 12 BLDC 250

Intelligent Positioner

Series 7000 Torque Sensor for PTO-shafts

P500 Pressure Sensor. Description. Features. Applications MAIN FEATURES

Pressure transmitters for industrial applications Type MBS 4510

Linear actuators DFPI

Pressure transmitter for industrial applications Type MBS 4500

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

MODEL: PSN3. Final Control Elements. STROKE 6: 0 to 60 mm (0 to 2.36 )

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

Series 7000 Torque Sensor for PTO-shafts

Transcription:

Temposonics Absolute, Non-Contact Position Sensors MH Series Temposonics Technical Data / Description Document Part Number 551405 Revision A Compact sensor for mobile hydraulics Designed for the mobile world MH sensors are designed for mobile machines and intended for IN cylinder use. They are validated in the field by worldwide OEM s and replace linear potentiometers and inductive sensors. Performance: Linearity < 0.04 % F.S. Resolution typ. ± 0.5 mm EMI up to 200 V/m capable for support tube assembly All specifications are subject to change. Contact MTS for specifications and engineering drawings that are critical to your application. Drawings contained in this document are for reference only. Please visit www.mtssensor.com for the actual support documentationrelated to your selected model.

1. Product description and technology Temposonics sensors can be used in versatile mobile machines without any restriction and replace contact-based linear sensors like potentiometers. Highly dynamic systems are controlled safely by means of Temposonics sensors, thus enhancing the productivity, availability and quality of the working process of the machine. Insensitive to vibration, shocks, dust and weathering influence and electro-magnetic disturbances. Temposonics MH Series sensors are successfully used in front axle and articulated frame steering cylinders, hydraulic jacks and in steering systems for hydraulic units on agricultural and construction machinery. 1 Temposonics Connector system (IP69K) 2 Flange housing 3 Position magnet 4 Pressure pipe Simple Mechanics The extremely robust sensor consists of the following main parts: 1 The innovative connector system which is easy to install in a few seconds, any soldering or crimping needless, dust-and waterproof up to IP69K. 2 The flange housing with built-in electronics and signal converter. 3 The position magnet as only moving part, which is assembled into the piston bottom. This permanent magnet travels wear-free and contactless along the pressure pipe and measures the actual position. 4 The pressure pipe placed within the drilled piston rod contains the protected magnetostrictive sensing element. Magnetostriction Temposonics linear sensors are based on the magnetostrictive technology. By measuring the actual position with a non-contact position magnet the sensor operates 100% wear-free. The absolute operating principle enables reliable readings without any reference point or recalibration. A mechanical strain pulse is triggered by the travelling position magnet. The runtime of this ultrasonic wave is measured precisely and compiled into standard electronic output signals. Magnetic field position magnet Magnetic field strain pulse - Due to small dimensions MH sensors require only little space - Suitable for operating pressures up to 300 bar - Unaffected by surrounding media such as ageing or foaming oil - Insensitive to shock and vibration - Designed for all current supply voltages (12/24 VDC) - Temposonics sensors offer all common used output signals: Analog: VDC / ma Bus protocols: CANopen, SAE J1939 Current interrogation pulse magnetostrictive sensing element (waveguide) Strain pulse detector Mechanichal strain pulse Moveable position magnet I 2 I

2. Temposonics connector system M12 MTS presents the innovative connector system for Temposonics MH-Series The Temposonics Connector System meets the highest protection requirements important for a harsh environment in mobile hydraulic applications. Protection type IP69K performs water and dust proof. In addition it is even resistive against high pressure water cleaning. 1 The MH sensor is delivered by MTS together with the new connector system: The connector insert carrier is already connected to the sensor conductors, i.e. no soldering, any colour or connection mistake. 2 The connector insert is taken out of the cylinder through a bore hole. The flange can easily be clicked in position from outside. 3 Four standard screws must be tightened to mount the connector 4 With a corresponding mating plug the connector system fulfills system on the cylinder. In case of using angled type connectors an IP rating of IP69K. the connector insert can be rotated inside the flange in 45 steps. - Absolutely easy and safe installation. - No brazing or crimping of connecting leads is required. I 3 I

3. Dimensions Housing 30 N (null stroke) s F.S. (full stroke) Z R2 d M12 1 Ø 48 f7 Ø 30 23.2 8.2 7F FD Ø 24 21.2 + 0-0.2 ± 0.2 11.5 Pressure pipe Ø 10 mm M6 female port (MHL) w 30 Mechanical configurations Model no. Form factor: stainless steel C L Z = 63 mm (s < 5000 mm) flat port Z = 63 mm (s < 5000 mm) M6 female port Stroke length s 2520 5000 mm Wire length w 60 240 mm MH C e.g.: s = 3860 mm L e.g.: w = 120 mm 3 8 6 0 M N 1 2 G 3 V02 H F F A01 C01 J01 Ø 30 Ø 48 f7 Stroke length 2520 5000 mm in 20 mm steps Electrical configurations MH Analog G H 1 = VDC 3 = GND 2 = Sig 4 = n.c. 1 = VDC 3 = GND 2 = Sig 4 = n.c. MH Digital F 2 = VDC 3 = GND 4 = CAN HI 5 = CAN LO 1 = n.c. MH Analog A01 V02 Wire length 60 240 mm in 20 mm steps All dimensions in mm 4-20 ma 0.5-9.5 VDC MH Digital C01 J01 CANopen SAE J1939 Baudrate Node ID 3 4 7F FD 250 kbit/sec 125 kbit/sec hex hex Please see detailed model configuration on page 11 and 13. 3 4 I 4 I

R2 Temposonics MH Series 30 30 N (null stroke) s F.S. (full stroke) Z + 0 24-0.2 Ø M12x1 Ø 30 Ø 48 f7 w All dimensions in mm Housing + 0 21.2-0.2 5 mm square 11.5 ±0.2 Pressure pipe Ø 10 mm Counter bracket Ø 14 mm M8 male port Mechanical configurations Form factor: stainless steel Q Z = 130 mm (s < 5000 mm) M8 male port Stroke length s 2520 5000 mm Wire length w 60 240 mm Model no. MH Q e.g.: s = 3860 mm e.g.: w = 120 mm 3 8 6 0 M N 1 2 G 3 A01 V02 H A01 F C01 F J01 Electrical configurations MH Analog G H 1 = VDC 3 = GND 2 = Sig 4 = n.c. 1 = VDC 3 = GND 2 = Sig 4 = n.c. MH Digital F 2 = VDC 3 = GND 4 = CAN HI 5 = CAN LO 1 = n.c. MH Analog A01 V02 4-20 ma 0.5-9.5 VDC MH Digital C01 J01 CANopen SAE J1939 Baudrate Node ID 3 4 7F FD 250 kbit/sec 125 kbit/sec hex hex Please see detailed model configuration on page 11 and 13. 3 4 7F FD I 5 I

4. In Cylinder assembly Mechanical installation The robust Temposonics model MH sensor is designed for direct stroke measurement in hydraulic cylinders. The Temposonics MH sensor can be installed from the head side or the rod side of the cylinder depending on the cylinder design. Example 30.00 Oil inlet >Ø 32.5 Hydraulic oil >15 21.2-0.2 Sensor installation The method of installation is entirely dependent on the cylinder design. While the most common method of installation is from the rod side of the cylinder, an installation from the head side of the cylinder is also possible. In both installation methods, the hermetic sealing of the cylinder is given by an O-ring with additional back up ring. 45 4 4.5 1 8.5 4.5 Please pay attention: The position magnet shall not touch the pressure pipe. The min. bore diameter in the piston rod is 13.5 mm. Do not exceed operating pressure. e.g. retaining with set screw DIN 913 M5 x 10 (with flat point!) max. torque 0.5 Nm Flange housing with O-ring and back-up ring B D d H h Type B Ø Cylinder D Ø min. H Depth d Ø min. h Depth All dimensions in mm MH 52 48 48 21.2 > 32.5 < 40 > 15 Please pay attention to installation manual! I 6 I

4.1 Position magnets for installation without support tube: MH models MHC and MHL Ø 17.4 8 Piston magnet (M) and magnet assembly with spacer (S) in piston. Part no.: 401032 OD Ø 13 mm OD 17.5 mm ID 13.5 mm H 8 mm C W M S d P A * 10 N/mm 2 Non-magnetic (stainless steel) POM, PU, Aluminum S = OD x 5 x ID Magnetic (steel) 4.2. Position magnets for installation with support tube: MH model MHQ 25.4 8 Ø 30.5 Ø 33 8 Part no.: 402316 Part no.: 000000-0 OD 30.5 mm OD 35.0 mm ID 20.0 mm ID 26.0 mm H 8.0 mm H 15.0 mm P A * 40 N/mm 2 P A * 40 N/mm 2 18 x 1.5 mm 22 x 2 mm Support tube Part no.: 401032 Part no.: 402316 Part no.: 000000 OD 17.5 mm 30.6 mm 35.1 mm d 13.0 mm 13.0 mm 15.0 mm Oil inlet Piston Support tube Hydraulic oil Please pay attention to installation manual! Adapter I 7 I

4.3 Support tube assembly for MH model MHQ Counter bracket Ø 14 mm M8 stud 90 5 mm square Assembly adapters Head topview Grooves to enable oilflow in support tube Ø24.1 +0.1 0 Chamfer 45 for concentric installation to sensor housing support tube spring tail head counter bracket lock nut Tail topview Grooves to enable oilflow in support tube ØD Ø10.1 +0.1 0 Ø8.1 +0.1 0 Support tube 18x1.5 22x2 ØD 18 22 OD 15 18 OD Adapters, support tube, locknuts, springs etc. are not part of MTS shipment Please pay attention to: Please consult MTS for detailed drawings - Support tube adapters must enable oilflow to get rid of air when cylinder gets oil filled - Support tubes material is stainless steel 1.4301 or AISI 304 - Nut M8 to tighten with max. 4 Nm. Use glue to fix the nut - Use a wrench 5 mm to hold the pressure pipe end when tighten the nut M8. - Spring washer or other springs required to eliminate manufacturing tolerances of support tube and adapters - No torsional stress to apply on the pressure pipe - Adapters material is stainless steel 1.4305 or AISI 303 I 8 I

5. Electrical installation MH Digital (5 pin) MH Analog (4 pin) topview PIN assignment Digital 5 pin topview PIN assignment Analog 4 pin 4 3 5 PIN 1 PIN 2 F n.c. VDC 4 3 H G PIN 1 VDC VDC PIN 2 signal n.c. 1 2 PIN 3 PIN 4 GND CAN HI 1 2 PIN 3 GND GND PIN 4 n.c. signal PIN 5 CAN LO Pin assignment (e.g. N10F) Pin assignment (e.g. N08H) (1) n.c. (2) +12/24 VDC (3) GND (O V) (4) CAN HI (5) CAN LO 120 Ω (1) +12/24 VDC (2) Signal: VDC (3) GND (O V) (4) n.c. 0 VDC M12 connector system M12 x 1 24 17 Please pay attention to installation manual! 9 10 12 16H8 Ø 4.4 Connecting schematics on vehicle electronics: VDC GND Signal 4 3 + - BAT +12/24 VDC 1 2 cable shielding GEN M Chassis GND All dimensions in mm I 9 I

6. MH Analog: Technical data / Model configurator Input Measured variables: Stroke range: Output Signal characteristic: Voltage: Current: Resolution: Power up time: Null zone: Damping: position 2520 5000 mm in 20 mm steps analog output restricted by noise or A/D converter of control unit 0.5 9.5 VDC 4 20 ma typ. 0.5 mm 3500 mm, typ. 1.5 mm 3500 mm typ. 250 ms 30 mm 63 mm with M6 female/flat port 130 mm with M8 male port Accuracy Linearity: typ. ± 0.04 % full stroke (F.S.) ± 1.0 mm s 3500 mm F.S. ± 2.0 mm s 3500 mm F.S. Hysteresis: ± 0.5 mm s 3500 mm F.S. ± 1.5 mm s 3500 mm F.S. Internal sample rate: 2 ms Setpoint tolerance: 1 mm Operating conditions Mounting position: any Operating temperature electronics: -40 C +105 C Storage temperature: -25 C +65 C Fluid temperature: -30 C +85 C Dew point, humidity: EN60068-2-30, 90 % rel. humidity, no condensation Pressure without considering support tube assembly Operating pressure ratings: Ø 10 mm pressure pipe pressure impulse test acc. DIN EN ISO 19879 PN: 300 bar Pmax: 400 bar Pstatic: 550 bar IP rating M12 connector: EN60529 (IP69K) plugged Sensor housing: EN60529 (IP67) Environmental testing without considering support tube assembly Shock: IEC 60068-2-27, 50 g (11 ms) single shock, 15 g (11 ms) at 1000 shocks per axis Vibrations: IEC 60068-2-64, 5 g (r.m.s.) Ø 10 mm pressure pipe (10 2000 Hz) - resonance frequencies excluded EMC: 2009/64/EG Road vehicles (e1 conform) 2009/19/EG Agricultural and Forest machines ISO 14982 Emissions/Immunity ISO 7637-1/2 Transient Impulses ISO / TR 10605 Electrostatic Discharge (E.S.D.) Materials and dimensions Pressure pipe: stainless steel 1.4306 / AISI 304L Housing: stainless steel 1.4305 / AISI 303 Sealing: O-ring 40.87 x 3.53 mm NBR 80, back-up ring 42.6 x 48 x 1.4 PTFE Support tube: stainless steel 1.4301 / AISI 304 Support tube adapter (head/tail): stainless steel 1.4305 / AISI 303 Electrical installation Connector: insert system M12x1 with O-ring 7 x 1.35 mm NBR 70 flange: brass nickel-plated with O-ring 13 x 1.6 NBR 70 Supply voltage: 12/24 VDC (tolerance range 8-32 VDC) Voltage supply ripple: < 1 % p-p Power drain: < 1 W 12 VDC: typ. < 100 ma 24 VDC: typ. < 50 ma Electric strength: 500 VDC (DC GND to chassis GND) Insulatioin Resistance R 10 MΩ @ 60 sec Over voltage protection (GND-VDC): up to +36 VDC Polarity protection (GND-VDC): up to -36 VDC Load: R L > 10 kω (output VDC); R L < 500 Ω (output ma @ 24 VDC); R L < 250 Ω (output ma @ 12 VDC) Inrush current: 12 VDC: max. 2.5 A @ 2 ms 24 VDC: max. 4.5 A @ 2 ms I 10 I

Temposonics Model configurator M H M 3 Sensor model MH - flange housing Ø 48 mm Form factor C - stainless steel housing / pressure pipe Ø 10 mm Z = 63 mm / s 5000 mm / flat port L - stainless steel housing / pressure pipe Ø 10 mm Z = 63 mm / s 5000 mm / M6 female port Q - stainless steel housing / pressure pipe Ø 10 mm Z = 130 mm / s 5000 mm / M8 male port Stroke length 2520 5000 mm in 20 mm steps Connection type Single wires with connector system M12 N G = 4 single wires (20 mm increments), M12 IP69K, 4 pin (pin assignment 1-3-4) N06G = 60 mm min. wire length N24G = 240 mm max. wire length N H = 4 single wires (20 mm increments), M12 IP69K, 4 pin (pin assignment 1-3-2) N06H = 60 mm min. wire length N24H = 240 mm max. wire length Supply voltage 3 - +12/24 VDC Output V02-0.5 9.5 VDC A01-4 20 ma Scope of delivery: Position sensor, O-ring, backup-ring M12 connector system Please order magnets seperately! Accessories (selection) Part no. OD17.4 Ring magnet, no support tube installation 401 032 OD30.5 Ring magnet, support tube installation 402 316 OD35 Ring magnet, support tube installation XXX XXX-X MH Testkit 280618 Scope of delivery: MH-Series analog / PWM Tester 12 VDC battery charger with adapter (adapter main plug EU, adapter main plug UK) cable with M12 connector cable with pigtailed wires carrying case CD-ROM with user s guide I 11 I

7. MH Digital: Technical data / Model configurator Input Measured variables: position and velocity Stroke range (position): 2520 5000 mm in 20 mm steps Measuring range (velocity): 0 1000 mm/s Output Signal characteristic: Bus-protocol: SAE J1939, CANopen protocol acc. CiA DS-301 V4.1, device profile DS-406 V3.1 Resolution (position): 0.5 mm Resolution (velocity): 1 mm/s Boot up time: typ. 400 ms Cycle time: CANopen: 1 ms SAE J1939: 20 ms Null zone: 30 mm Damping: 63 mm with M6 female port and flat port 130 mm with M8 male port Accuracy Linearity: typ. ± 0.04 % full stroke (F.S.) 1.0 mm, s 3500 mm F.S. 2.0 mm, s 3500 mm F.S. Hysteresis: ± 0.5 mm Internal sample rate: 1 ms Setpoint tolerance: ± 0.2 mm Operating conditions Mounting position: any Operating temperature electronics: -40 C +105 C Storage temperature: -25 C +65 C Fluid temperature: -30 C +85 C Dew point, humidity: EN60068-2-30, 90 % rel. humidity, no condensation Pressure without considering support tube assembly Operating pressure ratings: Ø 10 mm pressure pipe pressure pulse test acc. DIN EN ISO 19879 PN: 300 bar Pmax: 400 bar Pstatic: 550 bar IP rating M12 connector: EN60529 (IP69K), plugged Sensor housing: EN60529 (IP67) Environmental testing without considering support tube assembly Shock: IEC 60068-2-27, 50 g (11 ms) single shock, 15 g (11 ms) at 1000 shocks per axis Vibrations: IEC 60068-2-64, 5 g (r.m.s.) Ø 10 mm pressure pipe (10 2000 Hz) - resonance frequencies excluded EMC: 2009/64/EG Road vehicles (e1 conform) 2009/19/EG Agricultural and forest machines ISO 14982 Emissions/immunity ISO 7637-1/2 Transient impulses ISO / TR 10605 Electrostatic Discharge (E.S.D.) Materials and dimensions Pressure Pipe: stainless steel 1.4306 / AISI 304L Housing: stainless steel 1.4305 / AISI 303 Sealing: O-ring 40.87 x 3.53 mm NBR 80, back-up ring 42.6 x 48 x 1.4 PTFE Support tube: stainless steel 1.4301 / AISI 304 Support tube adapter (head/tail): stainless steel 1.4305 / AISI 303 Electrical installation Connector: connector system M12 x 1 with O-ring 7 x 1.35 mm NBR 70 connecting flange brass nickel-plated with O-ring 13 x 1.6 NBR 70 Supply voltage: 12/24 VDC (tolerance range 8-32 VDC) Voltage supply ripple: < 1 % p-p Power drain: < 1.5 W 12 VDC: typ. < 100 ma 24 VDC: typ. < 50 ma Electric strength: 500 VDC (DC GND to chassis GND) Insulatioin Resistance R > 10 MΩ @ 60 sec. Over voltage protection (GND - VDC): up to +36 VDC Polarity protection (GND - VDC): up to -36 VDC Bus termination (HI-LO): 120 Ω Inrush current: 12 VDC: max. 1.0 A @ 2 ms 24 VDC: max. 1.5 A @ 2 ms I 12 I

Temposonics Model configurator M H M 3 Sensor model MH = flange housing Ø 48 mm Form factor C = stainless steel housing / pressure pipe Ø 10 mm Z = 63 mm / s 5000 mm / flat port L = stainless steel housing / pressure pipe Ø 10 mm Z = 63 mm / s 5000 mm / M6 female port Q = stainless steel housing / pressure pipe Ø 10 mm Z = 130 mm / s 5000 mm / M8 male port Stroke length 2520 5000 mm in 20 mm steps Connection type Single wires with Connector System M12 N F = 4 single wires (20 mm increments), M12 IP69K, 5 pin N06F = 60 mm min. wire length N24F = 240 mm max. wire length Supply voltage 3 = +12/24 VDC Output C01 _ = CANopen cycle time 1 ms (default setting) J01 _ = SAE J1939 cycle time 20 ms (default setting) Baud rate 0-1000 kbit 1-800 kbit 2-500 kbit 3-250 kbit (default setting) 4-125 kbit 5 - reserved 6-50 kbit 7-20 kbit 8-10 kbit Node-ID: Source adress: for CANopen (C01) default setting für SAE J1939 (J01) default setting Scope of delivery Position sensor, O-ring, backup-ring M12 connector system Please order magnets seperately! CANopen: hex 01 7F SAE J1939: hex 01 FD 7F FD Accessories (selection) Part no. OD17.4 Ring magnet 401 032 OD30.5 Ring magnet, support tube installation 402 316 OD35 Ring magnet, support tube installation XXX XXX-X MH Testkit Part no. Software 625 129 Hardware/Scope of delivery: 254 267 MH-Series CANopen / J1939 Test Software installation CD USB CAN-modul kit: - USB CAN modul - USB CAN modul utility CD (with drives and description) - USB connector cable Cable with MTS M12 connector and RS232 connector Cable with core cable ends and RS232 connector Carrying case Installation manual on CD 12 V charger with adapter MH Test-Software Order information: For complete package please order both part numbers. I 13 I

Notes I 14 I

Notes I 15 I

www.mtssensor.com Document Part Number: 551405 Rev. A (EN) 07/2013 MTS and Temposonics are registered trademarks of MTS Systems Corporation. All other trademarks are the property of their respective owners. Printed in Germany. Copyright 2013 MTS Sensor Technologie GmbH & Co. KG. Alterations reserved. All rights reserved in all media. No license of any intellectual property rights is granted. The information is subject to change without notice and replaces all data sheets previously supplied. The availability of components on the market is subject to considerable fluctuation and to accelerated technical progress. Therefore we reserve the right to alter certain components of our products depending on their availability. In the event that product approbations or other circumstances related to your application do not allow a change in components, a continuous supply with unaltered components must be agreed by specific contract. MTS Sensor Technologie GmbH & Co. KG Auf dem Schüffel 9 58513 Lüdenscheid, Deutschland Tel. + 49-23 51-95 87 0 Fax + 49-23 51-5 64 91 E-Mail: info@mtssensor.de www.mtssensor.de MTS Systems Corporation Sensors Division 3001 Sheldon Drive Cary, N.C. 27513, USA Tel. + 1-919-677-0100 Fax + 1-919-677-0200 E-Mail: sensorsinfo@mts.com www.mtssensors.com MTS Sensors Technology Corp. 737 Aihara-cho, Machida-shi, Japan Tel. + 81-42-775-3838 Fax + 81-42-775-5516 E-Mail: info@mtssensor.co.jp www.mtssensor.co.jp