ONE STAGE GAS BURNERS RDBS SERIES

Similar documents
TWO STAGE PROGRESSIVE AND MODULATING GAS BURNERS RIELLO 40 GS/M SERIES GS 10/M 22/ kw GS 20/M 43/ kw

TWO STAGE GAS BURNER GULLIVER RSD SERIES RS5D 160/ kw

ONE STAGE GAS BURNER GULLIVER RSF SERIES RS5F kw

LOW NOx TWO STAGE GAS BURNERS GULLIVER BSD SERIES BS1D 16/19 52 kw BS2D 35/40 91 kw BS3D 65/ kw BS4D 110/ kw

ONE STAGE GAS BURNERS RS/1 SERIES RS 28/ kw RS 34/1 MZ kw RS 38/ kw RS 44/1 MZ kw

GULLIVER BSD SERIES. Low NOx Two Stage Gas Burners FIRING RATES. BS1D 16/19 52 kw BS2D 35/40 91 kw BS3D 65/ kw BS4D 110/ kw.

GULLIVER BS SERIES. Low NOx One Stage Gas Burners FIRING RATES. BS kw BS kw BS kw BS kw.

RS Series Two Stage Progressive Gas Burners

TWO STAGE GAS BURNERS

RIELLO 40 FS SERIES. One Stage Gas Burners FIRING RATES. FS kw FS kw FS kw FS kw FS kw FS kw GAS

RIELLO 40 GS SERIES. One Stage Gas Burners FIRING RATES. S kw S kw S kw S kw

TWO STAGE PROGRESSIVE GAS BURNERS

TECHNICAL DATA LEAFLET GAS. RS/1 Series. One Stage Gas Burners. RS 34/1 MZ kw RS 44/1 MZ kw.

TWO STAGE LIGHT OIL BURNERS PRESS G SERIES

RS/1 SERIES. One Stage Gas Burners RS 34/1 MZ RS 44/1 MZ kw kw GAS

RS SERIES. Two Stage Progressive Gas Burners FIRING RATES

RDB SERIES. One Stage Light Oil and Kerosene Burners FIRING RATES LIGHT OIL

RS/M SERIES. Modulating Gas Burners FIRING RATES

RIELLO 40 F SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL. F kw F kw F kw

RS/E-EV MZ SERIES. Modulating Gas Burners FIRING RATES

DB Series. Technical Data Leaflet. Industrial Dual Block Oil, Gas and Dual Fuel Burners. Industrial TS0086UK00

RL/M BLU SERIES. Low NOx Modulating Light Oil Burners FIRING RATES. LOW NOx T. M 190/ kw M 223/ kw

PRESS P/N - P/N ECO SERIES

PRESS G SERIES. Two Stage Light Oil Burners FIRING RATES

RES G MRBLU SERIES. Low NOx One Stage Light Oil Burners FIRING RATES. LOW NOx LIGHT OIL

RS/E BLU Series. Technical Data Leaflet. Low NOx Modulating Gas Burners. Low NOx Gas TS0087UK00

KOLHAPUR FOUNDRY & ENGINEERING CLUSTER

Light oil - kerosene burner

CODE MODEL TYPE PRESS GW 605 T80

CODE MODEL TYPE G3BF 490T G5BF 492T G5BF 489T53

Oil - kerosene burner

Kerosene - oil burner

GAS BURNERS BLU 3000 PR BLU 4000 PR

822 NOVAMIX GAS FLOW RATE ADJUSTMENT AS A FUNCTION OF THE AIR FLOW GAS/AIR RATIO 1:1 DOUBLE AUTOMATIC SOLENOID SHUT-OFF VALVE

OIL BURNERS MAIOR P 45 AB. techniques for energy saving MODEL. HYDRAULIC SYSTEM 220/380 V 60 Hz LB

GREENOx BT LOW RETURN TEMPERATURE DUAL BT WITH TILED BOILERS. GREENOx BT COND LOW RETURN TEMPERATURE WITH CONDENSER

ECONOMATIC REX/REXF REX/REXF DUAL STR

product Information on oil, gas and dual fuel burners Industrial burners 1,000 11,700 kw flexible and reliable

Oil, gas and dual fuel burners. Burner series

Emprendimiento Fénix Product Catalogue

Doing more for clean environment and energy saving

burners with or without fan. It conforms to EN C). APPROVAL EU type test approval as per EU Gas Appliance Directive.

Installation- and maintenance instruction BENTOFLEX ST 108 PL

Installation- and maintenance instruction ST120 S75/21

X4 Installation and Operation Manual - POWER FLAME INCORPORATED

S4562C 1085 COMBI BOARD APPLICATION. Contents PRODUCT HANDBOOK. General

PRODUCT RANGE

product Digital dual fuel burners Weishaupt dual fuel burners WGL30-C and WGL40-A ( kw) Information on compact burners

available in battery up to 4 units for a total of 560 kw

Installation- and maintenance instruction B20KA/K

VF VFH. elektrogas.com. Butterfly valves DN40 DN150 EE155-11/11

Installation- and maintenance instruction BENTOFLEX ST120KAV

Installation- and maintenance instruction B80-2/3

Weishaupt Monarch oil burners Sizes 1 and 3 1/2002 GB

PRODUCT RANGE A COMPLETE RANGE OF BURNERS FROM 17 TO kw

G72x Series Direct Spark Ignition Controls

Weishaupt Monarch oil burners Sizes 5 to 11 1/2002 GB

product Digital combustion technology Weishaupt oil burners, WL10 to WL40 ( kw) Information on compact burners

Gas Pressure Governors

Oil, Gas and Dual Fuel Burners

Weishaupt oil burners Sizes 30 to 70 1/2003 CA

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

Installation- and maintenance instruction BENTOFLEX ST133KA/K

SPARE PARTS LIST - July

Installation- and maintenance instruction B20K-2

Installation- and maintenance instruction B20KAV/KV

Updated technical data can be found in this document, supplemented by the Riello BX Burner Manual regarding commissioning checks and adjustments.

Valves. Rapid opening and closing solenoid valves VMR (E1110 rev /11/2012)

Energysaver 559FT. Rinnai New Zealand Limited Page 1 of 6 Rinnai Energysaver 559FT Spare Parts: 01-11

Gas burner Dual fuel burner. Gas burner. Series RG GG MG. Dual fuel burner. Series MK

Weishaupt gas burners Sizes 30 to 70 Version NR (NO x reduced)

Installation- and maintenance instruction B20KA/K

E Series CE Approved Intermittent Pilot Ignition Control

product Digital combustion technology Weishaupt gas burners, WG10 to WG40 ( kw) Information on compact burners

Governor with solenoid valve VAD Air/gas ratio control with solenoid valve VAG

P60 P72 MANUAL OF - INSTALLATION - OPERATING - MAINTENANCE GAS BURNERS TYPE: BURNERS BRULEURS BRENNER QUEMADORES BRUCIATORI.

EC 200 EC 300 GE 360 GE 400 GE 600 L-S BM

VMH. www. delta-elektrogas.com. Safety shut off valves for gas with hydraulic actuator DN65 DN200 EE

OIL BURNERS. MINOR 1 Snorkel 240 Volt 50 Hz

Electronic Ignition Module

product WM 30 for gas, oil, and dual-fuel WM 30 monarch burners ( kw) powerful and versatile Information on gas, oil, and dual-fuel burners

CATALOGUE A complete range of burners for all fuels MONOBLOCK kw DUOBLOCK kw

3 Edition Product brochure GB AGA

REX/REX F/REX K/REX K F REX DUAL/REX DUAL F

Installation- and maintenance instruction BENTOFLEX ST133K

INDUSTRY CATALOGUE.

Weishaupt Monarch oil burners Sizes 5 to 11 1/2002 CA

VLF45... Hot Air Valves. Siemens Building Technologies HVAC Products

BPF. Centrifugal Plug Fans

Combination controls CG 10

MODEL B360 E ILLUSTRATED PARTS BREAKDOWN UNIT 1. From Serial Number: Untill Serial Number: Edizione 2010 Rev. A. Cod

Valve monitoring system VDK 200 A S02

Tightness control TC. Product brochure GB Edition 12.10

CREATIVE EQUIPMENT CC 18 Main Road, Fishers Hill, Germiston, 1401 Tel: Fax:

product WM 20 for oil, gas and dual-fuel WM 20 monarch burners ( kw) compact and powerful Information on oil, gas and dual-fuel burners

HIGH PRESSURE COMPRESSORS FOR NATURAL GAS REFUELLING OF VEHICLES FOR PRIVATE USE. CATALOG 2018 CNG FILLING STATIONS

Heating and Gas Installations - December 2014

AMR. GB-Ganz Tüzeléstechnikai Kft. MODULATING DUOBLOCK BURNER FAMILY

G821L/G822L Series Integrated Function Direct Spark Ignition Controls

Gas oil/ Kerosene burners

Transcription:

ONE STAGE GAS BURNERS RDBS SERIES 16 47 kw RDBS.1 16 47 kw The Riello RDBS is a new series of one stage gas burners with integrated gas train, characterised by its small dimensions in spite of its high combustion performance. It is available in conventional flue and balanced flue versions. It has been developed to respond to any request for home heating, conforming to current regulations in force. The RDBS series is available in two models with an output range from 16 to 47 kw; the differences between the two models are the gas train and the combustion head. The model is made up of a class A gas train and a short flame combustion head, the RDBS.1 model is made up of a class B gas train and a standard flame combustion head. These models use the same components designed by Riello for RDB series. The high quality level guarantees safe working. In developing these burners, special attention was paid to reducing noise, the ease of installation and adjustment, to obtaining the smallest size possible to fit into any sort of boiler available on the market. These models are approved by the EN 676 European Standard and European Directives, Gas Appliance, EMC, Low Voltage, Boiler Efficiency. The RDBS burners are tested before leaving the factory. TS13UK1

TECHNICAL DATA Model RDBS.1 Approval Emissions Electrical data Fuel / air data Burner operation mode Modulation ratio at max. output type Servomotor run time s kw Heat output Mcal/h Working temperature C min./max. Net calorific value G2 gas kwh/nm 3 G2 gas density kg/nm 3 G2 gas delivery Nm 3 /h Net calorific value G2 gas kwh/nm 3 G2 gas density kg/nm 3 G2 gas delivery Nm 3 /h Net calorific value LPG gas kwh/nm 3 LPG gas density kg/nm 3 LPG gas delivery Nm 3 /h Fan type Air temperature max. C Electrical supply Ph/Hz/V Auxiliary electrical supply Ph/Hz/V Control box type Total electrical power kw Auxiliary electrical power kw Protection level IP Motor electrical power kw Rated motor current A Motor start up current A Motor protection level IP type Ignition transformer V1 - V2 I1 - I2 Operation Sound pressure db(a) Sound power W CO emission mg/kwh NOx emission mg/kwh Directive Conforming to Certification One stage One stage -- -- -- 16 47 16 47 13,8-4,4 13,8-4,4 /4 /4,71,71 1,6-4,7 1,6-4,7 8,6 8,6,78,78 1,9 -,46 1,9 -,46 2,8 2,8 2,2 2,2,6-1,8,6-1,8 Centrifugal with forward curve blades 4 4 1//23 ±% 1//23 ±% -- LANDIS LMG2 LANDIS LMG2,9,9 -- XD (IP 4) XD (IP 4),9,9,8,8 2,4 2,4 2 2 (BRAHMA) separated from the control box (--) - kv (--) - 2 ma Intermittent (at least one stop every 24 h) 9,4 9,4 -- 2 2 1 1 89/336/EEC, 73/23/EEC, 92/42/EEC, 9/396/EEC EN 676 CE-8BM49 in progress Reference conditions: Temperature: 2 C Pressure: 13 mbar Altitude: m a.s.l. Noise measured at a distance of 1 meter. Since the Company is constantly engaged in the production improvement, the aesthetic and dimensional features, the technical data, the equipment and the accessories can be changed. This document contains confidential and proprietary information of RIELLO S.p.A. Unless authorised, this information shall not be divulged, nor duplicated in whole or in part.

FIRING RATE 2 2, 2 2 - RDBS.1 1, 1 mm H 2 O hpa (mbar), 2 3 4 kcal/h 2 2 3 3 4 4 kw Useful working field for choosing the burner Test conditions conforming to EN 676: Temperature: 2 C Pressure: 13 mbar Altitude: m a.s.l.

FUEL SUPPLY GAS TRAINS The burners are fitted with the gas train. The gas train is Multibloc type, containing the main components in a single unit. The model is fitted with a class A gas train, the RDBS.1 model is fitted with a class B gas train. The max inlet pressure for both gas trains is 6 mbar. Gas train fixed in the burner MBDLE D1 - GB-LE D1 1 2 L1 3 4 6 P2 7 8 9 L 11 12 MULTIBLOC P3 13 P1 14 1 Gas delivery pipe 2 Manual valve 3 Vibration damping joint 4 Gas pressure gauge Manual shutter (supplied) 6 Filter 7 Gas pressure switch 8 Safety solenoid 9 Regulation solenoid Pressure regulator 11 Shutter with adjustment screws (brake regulator) 12 Pressure regulator setting device 13 Shutter with adjustment screws (solenoid regulator) 14 Gas train-burner adapter Burner P1 Combustion head pressure P2 Upstream pressure from the filter P3 Upstream pressure from the control valve L Gas train supplied separately L1 To be performed by the installer Name Example of MBDLE gas train MULTIBLOC MBDLE D1 GB-LE D1

PRESSURE DROP DIAGRAM The diagrams indicate the minimum pressure drop of the burners with the various gas trains that can be combined with them; the value thus calculated represents the minimum required input pressure to the gas train. NATURAL GAS LPG P mbar G2 G2 P mbar LPG combustion head + gas train combustion head MBDLE D1 combustion head + gas train combustion head MBDLE D1 Pressure loss 14 2 2 3 3 4 kcal/h X Pressure loss 14 2 2 3 3 4 kcal/h X 2 2 3 3 4 4 16 47 kw 2 2 3 3 4 4 16 47 kw Gas train MBDLE D1 RDBS.1 RDBS.1 P mbar G2 G2 P mbar LPG combustion head + gas train combustion head GB-LE D1 combustion head + gas train combustion head GB-LE D1 Pressure loss 14 2 2 3 3 4 kcal/h X Pressure loss 14 2 2 3 3 4 kcal/h X 2 2 3 3 4 4 16 47 kw 2 2 3 3 4 4 16 47 kw Gas train GB-LE D1 note For pressure levels different from those indicated above, please contact Riello Burners Technical Office.

3" SELECTING THE FUEL SUPPLY LINES The following diagram enables pressure drop in a pre-existing gas line to be calculated and to select the correct gas train. The diagram can also be used to select a new gas line when fuel output and pipe length are known. The pipe diameter is selected on the basis of the desired pressure drop. The diagram uses methane gas as reference; if another gas is used, conversion coefficient and a simple formula (on the diagram) transform the gas output to a methane equivalent (refer to figure A). Please note that the gas train dimensions must take into account the back pressure of the combustion chamber during operations. Control of the pressure drop in an existing gas line or selecting a new gas supply line. The methane output equivalent is determined by the formula fig. A on the diagram and the conversion coefficient. Once the equivalent output has been determined on the delivery scale ( V ), shown at the top of the diagram, move vertically downwards until you cross the line that represents the pipe diameter; at this point, move horizontally to the left until you meet the line that represents the pipe length. Once this point is established you can verify, by moving vertically downwards, the pipe pressure drop of on the botton scale below (mbar). By subtracting this value from the pressure measured on the gas meter, the correct pressure value will be found for the choice of gas train. Example: - gas used G2 - gas output 9.1 mc/h - pressure at the gas meter 2 mbar - gas line length m - conversion coefficient.62 (see figure A) - equivalent methane output V = 9.1 =.34 mc/h.62 - once the value of.34 has been identified on the output scale ( V ), moving vertically downwards you cross the line that represents 1" 1/4 (the chosen diameter for the piping); - from this point, move horizontally to the left until you meet the line that represents the length of m of the piping; - move vertically downwards to determine a value of 1.4 mbar in the pressure drop botton scale; - subtract the determined pressure drop from the meter pressure, the correct pressure level will be found for the choice of gas train; - correct pressure = ( 2-1.4 ) = 18.6 mbar 3 4 61 76 9 122 2 V 1 2 3 4 6 7 8,34 2 3 4 22 12 9 6 6 8 2 4 6 8 3 6" PIPE LENGTH (m) 4" 2" 1/2 2" V = Gas output Nmc/h f 1" 1" 1/4 1" 1/2 3/4 f 1 - G2 =,62 - G2 {1,18 - G31 1/2 Figure A 1,4,1,2,3,4,,6,7,8 1 2 3 4 6 2 PRESSURE DROP (mbar) PIPE DIAMETER

VENTILATION The ventilation circuit ensures low noise level with high performance of pressure and air delivery, in spite of their compact size. The burner is fitted with an adjustable air pressure switch, conforming to EN 676 standards. Air suction COMBUSTION HEAD The combustion head in is the result of an innovative design, which allows combustion with low polluting emissions, while being easy to adapt to all various types of boilers and combustion chambers. The RDBS.1 model is fitted with a standard combustion head. Simple adjustment allows the internal geometry of the combustion head to be adapted to the burner output. Dimensions of the flame Combustion head 2 Flame length (m) 1 L max L min D max D min 1, Flame diameter (m) D L 2 3 4 Burner output (kw) Example: Burner thermal output = 3 kw; L flame (m) = 1,2 m (medium value); D flame (m) =,6 m (medium value)

ADJUSTMENT BURNER OPERATION MODE The RDBS models are one stage operation. One stage operation Output Checked variable C bar ON OFF ON OFF time time Air damper Air damper adjustment START UP CYCLE Thermostat M Ignition transformer V1 Normal Lock-out due to ignition failure (A) Lock-out Air pressure gauge 2, s 2 s 4 sm 2, s 2 s 4 sm 37 s 3 s 3 s 36 s time (s) time (s) (A) Lock-out is shown by a led on the appliance. Correct operation s The burner begins the ignition cycle. 2,s - 39,s Pre-purge with the air damper open. 39,s - 42,s The ignition transformer starts. Lock-out due to ignition failure If the flame does not light within the safety limit (3s) the burner locksout. When the flame-failure occurs during working, shut down takes place within one second.

WIRING DIAGRAMS Electrical connections must be made by qualified and skilled personnel, in conformity with the local regulations in force. These models are fitted with socket for electrical connection. Control box ONE STAGE OPERATION Burner electrical wiring RDBS.1 ~ Hz 23V ~ Hz 23V L N L N F F ϑ P TL XP4-4 pole socket XP7-7 pole socket X4-4 pin plug X7-7 pin plug B4 - Working signal H1 - Hour counter S3 - Lock out led TL - Regulation thermostat TS - Safety thermostat (manual reset) F - Fuse TS ϑ TL ϑ X4 XP4 L1 N L2 S3 TS P ϑ X7 L1 XP7 N S3 B4 T1 T2 S3 B4 h1 The following table shows the supply lead sections and types of fuse to be used. Model F L F = Fuse A mm 2 - RDBS.1 23V T6 1 L = Lead section

EMISSIONS The emission data have been measured at maximum output, in conformity with EN 676 standard. mg/kwh NO2 EMISSIONS 12 8 6 4 2 - RDBS.1 mg/kwh 4 3 2 CO EMISSIONS - RDBS.1 db(a) SOUND EMISSIONS (sound pressure) 8 7 6 4 3 2 - RDBS.1 OVERALL DIMENSIONS (mm) Thanks to certain construction features, these models can be fitted to any boiler on the market. BURNER B C F E H D I L Model B C D E F H I L RDBS.1 19 19 141 141 222 222 27 27 1 1 89 89 168 168 2 2 BURNER-BOILER MOUNTING FLANGE F A-D Q Q C1 R S T Model RDBS.1 A 91 91 C1 13 13 C2 D 91 91 F 18 18 Q 4 4 R 11 11 S 72 72 T 72 72 C2 PACKAGING Z X Y Model RDBS.1 X Y Z kg 4 36 3 12 4 36 3 12

INSTALLATION DESCRIPTION Installation, start up and maintenance must be carried out by qualified and skilled personnel. The burner is set in the factory on standard calibration (minimum output), if necessary adjustments can be made on the basis of the maximum output of the boiler. All operations must be performed as described in the technical handbook supplied with the burner. BURNER SETTINGS The air damper position can be adjusted without removing the burner cover. Combustion head is fixed. burner is fitted with an air pressure switch which, in accordance with EN 676 standards, can be adjusted by the installer using a graduated selector, on the basis of the effective working conditions. The gas train is incorporated in the burner and can be easily adjusted without removing the burner cover. MAINTENANCE AND ELECTRICAL CONNECTIONS Maintenance is easily solved disassemblying the combustion head. The socket is fixed on the top of the burner.

BURNER ACCESSORIES Balanced-conventional flue conversion kit All the RDB series models are easily converted from conventional flue to balanced flue, by replacing the plastic screen on the air intake with the connector for the air supply pipe. The reverse operation can be carried out on all the models from balanced flue to conventional flue burner, by replacing the connector on the air supply pipe with the plastic screen on the air intake. Burner - RDBS.1 Balanced-conventional flue conversion kit Balanced flue kit code 362774 Conventional flue kit code 36277 LPG kit For burning LPG gas, a special kit is available to be fitted to the combustion head on the burner as shown in the following table. Burner - RDBS.1 LPG kit Kit code for standard head 376 Kit code for extended head -

SPECIFICATION A special index guides your choice of boiler according to these models. Below there is a clear and detailed specification description of the product. DESIGNATION OF SERIES Series : RDB Fuel : S Natural gas Size Electrical supply to the system : 1/23/ 1/23V/Hz RDB S 1 1/23/ AVAILABLE BURNER MODEL 1/23/ RDBS.1 1/23/

PRODUCT SPECIFICATIONS Burner Monoblock, gas burner, completely automatic, with one stage operation made up of: - Fan with forward curve blades - Cover lined - Air damper, with external adjustment, with no need to remove the cover - Single phase electric motor 23 V, Hz - Combustion head fitted with: - stainless steel head cone, resistant to high temperatures - ignition electrodes - ionisation probe - gas distributor - flame stability disk - Incorporated gas train - Adjustable air pressure switch, with graduated selector, to guarantee burner lock out in the case of insufficient combustible air - Protection filter against radio interference - IP XD (IP 4) electric protection level. Gas train Fuel supply line in the Multibloc configuration, fitted with: - Filter - Pressure stabiliser - Minimum gas pressure switch - Safety valve - Single stage working valve with ignition gas output regulator. Approval: - EN 676 standard. Conforming to: - Directive 9/396/EEC (gas appliance) - Directive 73/23/EEC (low voltage) - Directive 89/336/EEC (electromagnetic compatibility) - Directive 92/42/EEC (efficiency). Standard equipment: - Flange with insulating gasket - 4-pin plug - Screws and nuts for flange to be fixed to boiler - Protection grill for CF application - 9 manual gate valve - Tube 1/2 - Flange 9 - Instruction handbook for installation, use and maintenance - Spare part catalogue. RDBS.1 - Flange with insulating gasket - Screws and nuts for flange to be fixed to boiler - Flange 9 - Instruction handbook for installation, use and maintenance - Spare part catalogue. Available accessories to be ordered separately: - Balanced-conventional flue conversion kit - LPG kit.

Lineagrafica ISO 91 Cert. n. 61 RIELLO S.p.A. - Via degli Alpini, 1-374 LEGNAGO (VR) Italy Tel. ++39.44263111 - Fax ++39.4422198 Internet: http://www.rielloburners.com - E-mail: rburners@rielloburners.com Since the Company is constantly engaged in the production improvement, the aesthetic and dimensional features, the technical data, the equipment and the accessories can be changed. This document contains confidential and proprietary information of RIELLO S.p.A. Unless authorised, this information shall not be divulged, nor duplicated in whole or in part.