1 GAS BURNERS techniques for energy saving MODELS BLU 3000 PR BLU 4000 PR 220/380 V 60 Hz L.P.G. LB
2 TECHNICAL DATA MODELS BLU 3000 PR BLU 4000 PR Thermal power max. kcal/h kw Thermal power min. kcal/h kw Max. capacity (L.P.G.) Nm 3 /h Min. capacity (L.P.G.) Nm 3 //h Max. gas pressure mbar Min. gas pressure mbar Voltage 60 Hz V 220/ /380 Motor kw 7,5 9 Rpm N Ignition transformer kv/ma 13/35 13/35 Control box LANDIS LFL LFL Gas valve safety 2 2 work 2 2 Fuel : L.P.G kcal/nm 3 WORKING FIELDS Pressure in the combustion control mbar BLU 3000 PR BLU 4000 PR kw Burner output kcal/h x 1000 pag.2
3 I O OVERALL DIMENSIONS E D - D1 B A C L F I M H G MODELS A B C D D1 E F G H I L M BLU 3000 PR BLU 4000 PR D = Short head D1= Long head BURNER INSTALLATION BURNER 2 - NUT 3 - WASHER 4 - GASKET 5 - BOLT 6 - BOILER 7 - GASKET GAS TRAIN INSTALLATION MAIN GAS PIPE 2 - BALL VALVE 3 - GAS FILTER 4 - PRESSURE GAUGE FIXING POINT 5 - GAS PRESSURE SWITCH (MIN) 6 - SAFETY SOLENOID VALVE 7 - SOLENOID VALVE pag.3
4 BURNER START-UP Before starting the burner, make sure it is mounted correctly. Then check connections are correct according to the diagram and piping is appropriate to the system. Before connecting the burner to the electricity supply, make sure voltage corresponds to burner plate data. The connection diagram and startup cycle are shown separately. For wiring from control box to burner, see the enclosed connection diagram. Pay particular attention to neutral and phase connections : never exchange them!. Vent air and impurities of gas pipe. Check gas pressure conforms to the limits stated on the burner plate when connecting a master gauge to the test port provided on the burner. Blower motor starts and pre-purging begins. Since pre-purging has to be carried out with the max. air delivery, the burner control circuit turns the air damper to the max. delivery position by the air servocontrol in approximately 30 seconds time. When the servocontrol is fully open, a signal to the electronic control unit starts the 66 seconds pre-purge cycle. At the end of the prepurging time, the air servocontrol gets to the Low Flame position so that burner ignition is ensured at min. output. Simultaneously the ignition transformer receives voltage and after 3 seconds (pre-ignition) opens the gas valve. Fuel flows to the combustion head and ignites, being governed by the gas firing butterfly valve. Two seconds after gas valves have opened, the ignition transformer is excluded from the circuit. In case of no ignition the burner goes to lock-out within two seconds. Now the burner is operating at the min. firing rate (about 30% of the max. firing rate). The air servocontrol runs at the Low Flame position and in case the temperature control has to be set at the max. output it goes to a fully open position of air damper and butterfly valve. During the burneroff periods the air dumper closes up fully. A T SOLENOID GAS HONEYWELL VE 40...C1002 Adjustment of the initial output : Regulation of 0-40% of the max. output. The adjustment in the factory is done with a medium initial output. The damper is completely effective. Changing of the initial output : take out the screw A, take off the cover T and turn screw H. Turn the screw to the right to obtain a reduction of the ignition output. Turn the screw to the left to obtain an increase of the ignition output. To find the right ignition regulation tighten or loosen the screw H accordingly with on turn and start the burner. Check if the ignition has set off correctly, otherwise tighten or loosen the screw again accordingly with one turn. H D To regulate the gas output thighten or loosen the D with a screwdriver of 12 mm. Reduce gas pressure by turning screw clockwise. Increase gas pressure by turning screw counterclockwise. At end of regulation put on the cover T with screw A. pag.4
5 Q N.B. : The 3 screws must be taken off only when changing the coil. AIR ADJUSTMENT AIR: "LOW FLAME" adjustment is attained by loosening screw B and hand-moving damper C to the desired set-point = OFF 1 = HIGH FLAME 2 = LOW FLAME 3 = AUTOMATIC E - C T B AIR: "HIGH FLAME" adjustment is attained by loosening nut E and moving rod T along the guide as desirer. This will cause the damper to shift and the desirer air delivery will be obtained. After regulation place the switch on the automatic position. GAS BUTTERFLY VALVE REGULATION Adjustment is attained by loosening the screw A and regulating the butterfly valve with a screwdriver.turn the screw to the right to obtain an increase of the ignition output. Turn the screw to the left to obtain reduction of the ignition output. A - Q I - P Sector regulator (to control gas supply ranging from 0 to 100% of max. output). The regulation of gas supply to the butterfly is carried out by tightening or lossening the bolts I in the sector regulator Q by means of an elbowspanner. The movement of the butterfly is controlled by the rod and the pivot according to the shape taken by the blade P in the different position. N.B. : Any setting is to be carried out when burner is on. pag.5
6 - AIR DAMPER MOTOR ADJUSTMENT SQL CAM 1 - Max open position of the air damper ( 90 ). This cam is set at 90 and must not be adjusted. CAM 2 - Starting position of the ignition flame (from 0 to 5 ). CAM 3 - Low flame position. During gas operation, this cam must always be adjusted at least at 5 more than cam n 2. CAM 4 - NOT USED. FIRING HEAD SETTING pag.6
7 BLAST TUBE AND FIRING HEAD DISASSEMBLY ; IGNITION ELECTRODES 3 mm IONIZATION CURRENT The minimum current necessary to operate the control box is 70 µa. When the measurement of the current is required it is necessary to disconnect the lead to the probe and insert in its place a microammeter for direct current ( see fig. under) UV CELL Probe connecting point on control-box LANDIS LFL min. 70 µa Microammeter full-scale 1000 µa pag.7
8 pag.8
9 pag.9
10
11
12 DESIGN AND SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE La ECOFLAM S.p.A si riserva il diritto di apportare ai prodotti quelle modifiche che riterrà necessarie o utili, senza pregiudicarne le caratteristiche principali. Ecoflam S.p.A. via Roma, RESANA (TV) - Italy - tel. 0423/ r.a. - telex ECOFLA I - telefax 0423/715444
OIL BURNERS MAIOR P 45 AB. techniques for energy saving MODEL. HYDRAULIC SYSTEM 220/380 V 60 Hz LB
OIL BURNERS techniques for energy saving MODEL MAIOR P 45 AB HYDRAULIC SYSTEM 220/380 V 60 Hz LB462 09.12.99 TECHNICAL DATA MODEL MAIOR P 45 AB Thermal power max. kcal/h 450.000 kw 522 Thermal power min.
More informationOIL BURNERS. MINOR 1 Snorkel 240 Volt 50 Hz
OIL BURNERS MINOR 1 Snorkel 240 Volt 50 Hz 420010675700 04.06.2015 TECHNICAL DATA MODEL MINOR 1 SNORKEL Thermal power max kcal/h 25500 kw 29,6 Thermal power min kcal/h 17300 kw 20 Max capacity light oil
More informationONE STAGE GAS BURNERS RDBS SERIES
ONE STAGE GAS BURNERS RDBS SERIES 16 47 kw RDBS.1 16 47 kw The Riello RDBS is a new series of one stage gas burners with integrated gas train, characterised by its small dimensions in spite of its high
More informationTWO STAGE PROGRESSIVE AND MODULATING GAS BURNERS RIELLO 40 GS/M SERIES GS 10/M 22/ kw GS 20/M 43/ kw
TWO STAGE PROGRESSIVE AND MODULATING GAS BURNERS RIELLO GS/M SERIES GS /M / 5 3/8 19 The Riello GS/M series of two stage progressive or modulating gas burners, is a complete range of products developed
More informationP60 P72 MANUAL OF - INSTALLATION - OPERATING - MAINTENANCE GAS BURNERS TYPE: BURNERS BRULEURS BRENNER QUEMADORES BRUCIATORI.
BURNERS BRULEURS BRENNER QUEMADORES BRUCIATORI MANUAL OF - INSTALLATION - OPERATING - MAINTENANCE GAS BURNERS TYPE: P60 P72 M03956CE Rev.04 Ed.11/98 FOREWORD Page 2 PART I: INSTALLATION Page 4 PART II:
More informationRS SERIES. Two Stage Progressive Gas Burners FIRING RATES
The RS burners series covers a firing range from 44 to 2290 kw, and it has been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers. Operation
More informationONE STAGE GAS BURNER GULLIVER RSF SERIES RS5F kw
ONE STAGE GAS BURNER GULLIVER RSF SERIES 160 330 kw The Riello Gulliver, is a new model of the series of one stage gas burners, developed to respond to any request for light industrial processes like bakery
More informationCODE MODEL TYPE PRESS GW 605 T80
Installation, use and maintenance instructions Pressure jet burner CODE MODEL TYPE 3473784 PRESS GW 605 T80 291 (2) - 08/2012 Thermal power 107 / 178-350 kw - 92.000 / 153.000-301.000 kcal/h Output 9/15-30
More informationTWO STAGE GAS BURNER GULLIVER RSD SERIES RS5D 160/ kw
TWO STAGE GAS BURNER GULLIVER RSD SERIES 160/208 345 kw The Riello Gulliver is a new model of the series of two stage gas burners, characterized for its small dimensions in spite of its high combustion
More informationRS/M SERIES. Modulating Gas Burners FIRING RATES
The RS/M burners series covers a firing range from 45 to 2650 kw, and it has been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers. Operation
More informationRS/E-EV MZ SERIES. Modulating Gas Burners FIRING RATES
The RS/E-EV MZ burners series covers a firing range from 44 to 2650 kw, and it is based on a new Digital Burner Management System, Riello REC27, which is able to manage the air-fuel ratio by independent
More informationCODE MODEL TYPE G3BF 490T G5BF 492T G5BF 489T53
Installation, use and maintenance instructions Kerosene burners One stage operation CODE MODEL TYPE 3749053 G3BF 490T53 374957 G5BF 49T57 3748953 G5BF 489T53 9036 (6) TECHNICAL FEATURES TYPE - Boiler
More informationLight oil - kerosene burner
Installation, use and maintenance instructions Light oil - kerosene burner One stage operation CODE MODEL TYPE 3747455 G0KI 474T5 90403 (4) - 0/008 TECHNICAL DATA Thermal power output 95 3 kw 8 8 kg/h
More informationGULLIVER BSD SERIES. Low NOx Two Stage Gas Burners FIRING RATES. BS1D 16/19 52 kw BS2D 35/40 91 kw BS3D 65/ kw BS4D 110/ kw.
The Riello Gulliver BSD series of two stage gas burners, is a complete range of Low NOx emission products, developed to respond to any request for home heating, conforming to the most severe standards
More informationRIELLO 40 F SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL. F kw F kw F kw
The Riello 40 F series of one stage light oil burners, is a complete range of products developed to respond to any request for light industrial applications. The Riello 40 F series is available in three
More informationRIELLO 40 GS SERIES. One Stage Gas Burners FIRING RATES. S kw S kw S kw S kw
The Riello 40 GS series of one stage gas burners, is a complete range of products developed to respond to any request for home heating. The Riello 40 GS series is available in four different models, with
More informationLOW NOx TWO STAGE GAS BURNERS GULLIVER BSD SERIES BS1D 16/19 52 kw BS2D 35/40 91 kw BS3D 65/ kw BS4D 110/ kw
LOW NOx TWO STAGE GAS BURNERS GULLIVER BSD SERIES 1/19 5 kw 35/4 91 kw 5/75 19 kw 11/14 4 kw The Riello Gulliver BSD series of two stage gas burners, is a complete range of Low NOx emission products, developed
More informationRS/1 SERIES. One Stage Gas Burners RS 34/1 MZ RS 44/1 MZ kw kw GAS
The RS/1 series of burners covers a firing range from 70 to 550 kw, and they have been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers.
More informationGULLIVER BS SERIES. Low NOx One Stage Gas Burners FIRING RATES. BS kw BS kw BS kw BS kw.
The Riello Gulliver BS series of one stage gas burners, is a complete range of Low NOx emission products, developed to respond to any request for home heating, conforming to the most severe standards regarding
More informationOil - kerosene burner
Installation, use and maintenance instructions Oil - kerosene burner One stage operation CODE MODEL TYPE 374445 G5 444T50 9038 () TECHNICAL FEATURES Thermal power output 8 0 kw.3 5 kg/h Fuel Gas oil 35s,
More informationRL/M BLU SERIES. Low NOx Modulating Light Oil Burners FIRING RATES. LOW NOx T. M 190/ kw M 223/ kw
LOW NOx T The RL/M BLU burners series covers a firing range from 360 to 1023 kw, and it has been designed for use in hot or superheated water boilers, hot air or steam generators and diathermic oil boilers.
More informationPRODUCT RANGE A COMPLETE RANGE OF BURNERS FROM 17 TO kw
www.ecoflam-burners.com PRODUCT RANGE 2015 A COMPLETE RANGE OF BURNERS FROM 17 TO 34000 kw CUTTING-EDGE BURNERS FOR HEATING AND INDUSTRIAL APPLICATIONS Our proposal Ecoflam offers a full range of blown
More informationVALUPAK. Packaged gas burners
VALUPAK Packaged gas burners Low Temperature Burners - VALUPAK 1-1.5-1 High turndown. Available in 6 sizes. Capacities: 2 kw -1124 kw (HHV). Stable and clean combustion. Suitable for UV scanner and flame
More informationRDB SERIES. One Stage Light Oil and Kerosene Burners FIRING RATES LIGHT OIL
The Riello RDB series of one stage light oil and kerosene burners is available in eleven basic models, with an output ranging from 16,8 to 120 kw, in three different structures. The models are available
More informationRIELLO 40 FS SERIES. One Stage Gas Burners FIRING RATES. FS kw FS kw FS kw FS kw FS kw FS kw GAS
The Riello 40 FS series of one stage gas burners, is a complete range of products developed to respond to any request for light industrial application. The Riello 40 FS series is available in five different
More informationCATALOGUE A complete range of burners for all fuels MONOBLOCK kw DUOBLOCK kw
CATALOGUE 2012 LIGHT OIL BURNERS HEAVY OIL BURNERS GAS BURNERS GAS/LIGHT OIL BURNERS GAS/HEAVY OIL BURNERS DUOBLOCK BURNERS A complete range of burners for all fuels MONOBLOCK 20-10 kw DUOBLOCK 350-20
More informationPRESS P/N - P/N ECO SERIES
The PRESS P/N series of burners covers a firing range from 800 to 5130 kw. They have been designed in three versions for use in commercial and industrial installation, to burn different oil viscosity from
More informationKerosene - oil burner
Installation, use and maintenance instructions Kerosene - oil burner Two stage operation CODE MODEL TYPE 3746686 G0D 76T8 90 (0) TECHNICAL FEATURES Thermal power output 44 / 54 0 kw 3.7 / 4.5 0 kg/h Fuel
More informationONE STAGE GAS BURNERS RS/1 SERIES RS 28/ kw RS 34/1 MZ kw RS 38/ kw RS 44/1 MZ kw
ONE STAGE GAS BURNERS RS/1 SERIES RS 28/1 163 349 kw RS 34/1 MZ 7 39 kw RS 38/1 232 465 kw RS 44/1 MZ 55 kw The RS/1 series of burners covers a firing range from 7 to 55 kw, and they have been designed
More informationDB Series. Technical Data Leaflet. Industrial Dual Block Oil, Gas and Dual Fuel Burners. Industrial TS0086UK00
Technical Data Leaflet Industrial TS0086UK00 DB Series Industrial Dual Block Oil, Gas and Dual Fuel Burners DB 4 1000/2500 5000 kw DB 6 1400/4000 7800 kw DB 9 1500/5000 9500 kw DB 12 1700/7000 12500 kw
More information24 V AC/DC, -10%..+20%, 0-60Hz. 250 ma for max 2 min
Technical Data Sheet Thermoelectric Heads TE 16/03/2018 Function s function by exploiting the expansion of a thermosensitive element, which is heated up through an electrical resistor when the valve needs
More informationOIL BURNERS MAIOR P PR MAIOR P PR. techniques for energy saving LB 1326 GASTEC
OIL BURNERS techniques for energy saving GASTEC MAIOR P 150.1 PR MAIOR P 200.1 PR LB 1326 23.02.2004 SUNTEC LB1326 Maior P 150.1/200.1 AB TECHNICAL DATA MODELS MAIOR P 150.1 PR MAIOR P 200.1 PR Thermal
More informationX4 Installation and Operation Manual - POWER FLAME INCORPORATED
7.13.2 Set the burner s combustion air inlet damper to the approximate setting as shown in this manual for the desired firing rate. Also, verify that the correct main orifice is installed in the main orifice
More informationPRESS G SERIES. Two Stage Light Oil Burners FIRING RATES
The PRESS G series of burners covers a firing range from 107 to 1660 kw and they have been designed for use in civil installations of average dimensions, like building areas and large apartment groups
More informationRS Series Two Stage Progressive Gas Burners
Technical Data Leaflet Gas TS0046UK06 RS Series Two Stage Progressive Gas s RS 34 MZ 70/130 390 kw RS 44 MZ 101/203 550 kw RS 50 116/290 580 kw RS 64 MZ 150/400 850 kw RS 70 192/465 814 kw RS 100 232/698
More informationburners with or without fan. It conforms to EN C). APPROVAL EU type test approval as per EU Gas Appliance Directive.
LAST UPDATE 29/08/12 INSTALLATION INSTRUCTIONS v. 3 UNIT SPECIFICATIONS Main Gas Valve, Pilot Gas Valve Ionisation, Ignition and Flame Monitoring with Common Electrode or Remote Sensor Integrated Cyclic
More informationTWO STAGE PROGRESSIVE GAS BURNERS
TWO STAGE PROGRESSIVE GAS BURNERS RS SERIES RS 28 81/163 325 RS 34 MZ 7/125 39 RS 38 15/232 44 RS 44 MZ 1/2 55 RS 5 116/29 58 RS 64 MZ 15/4 85 RS 7 192/465 814 RS 1 232/698 1163 RS 13 372/93 1512 RS 19
More informationCompression Fittings. Serie 50th 01/03/2018. Technical Data Sheet
Technical Data Sheet Compression Fittings Serie 50th 01/03/2018 Function The Serie 50th range of compression fittings was created to fit all types of installation of Serie 50 th and Serie 30 valves. They
More informationInstallation- and maintenance instruction ST120 S75/21
Installation- and maintenance instruction ST120 S75/21 1 171 615 30 05-01 178 058 15 DESCRIPTION Components 1. Reset button 2. Control box 3. Ignition transformer 4. Ignition cables 5. Nozzle assembly
More informationTWO STAGE GAS BURNERS
TWO STAGE GAS BURERS RS SERIES RS 28 81/16 25 kw RS 8 /22 44 kw RS 5 116/29 58 kw RS 7 192/465 814 kw RS 1 22/698 116 kw RS 1 72/9 12 kw RS 19 47/1279 229 kw The RS series of burners covers a firing range
More informationDW - DW VOX SUBMERSIBLE SEWAGE PUMPS
DW - DW VOX SUBMERSIBLE SEWAGE PUMPS DW - DW VOX EBARA presents the DW - DW VOX Submersible Pump. The ONLY submersible pump for light screened Sewage and dirty water. The pump is manufactured entirely
More informationM SERIES TECHNICAL DATA INFORMATION PACKET
M SERIES TECHNICAL DATA INFORMATION PACKET Table of Contents Uncontrolled Emissions MG, MM#2, MMG#2 Technical Data Sheet... Ratings Table...4 Dimensions Table...5 Uncontrolled Emissions MM, MMG Technical
More informationOil, gas and dual fuel burners. Burner series
Oil, gas and dual fuel burners Burner series 350...450 Group 4B Capacity 700-5500 kw 1 2 Table of contents General 5 Light fuel oil burners 6 Dimensions and PI diagram 6 Technical data 7 Capacity/back
More informationPower Flame Incorporated
Power Flame Incorporated SUGGESTED SPECIFICATION FOR MODEL HP COMBINATION GAS/OIL BURNERS THE POWER TO MANAGE ENERGY 2001 South 21st Street, Parsons, Kansas 67357 Telephone 316-421-0480, Fax 316-421-0948
More informationRES G MRBLU SERIES. Low NOx One Stage Light Oil Burners FIRING RATES. LOW NOx LIGHT OIL
Low NOx One Stage Light Oil Burners RES G MRBLU SERIES LOW NOx LIGHT OIL RES (Riello Environment Solution) is the new Low NOx light oil burners series with extremely low emissions to meet the increasingly
More informationCompression Fittings TR - TP 23/03/2018. Technical Data Sheet
Technical Data Sheet Compression Fittings TR - TP 23/03/2018 Function Luxor manufactures a wide range of compression fittings to fit all types of installation. This includes fittings for copper (or mild
More informationEclipse RatioAir Burners
Parameter Maximum Input, BTU/hr (kw) 1, Minimum Input, BTU/hr (kw) Lower inputs may be achieved. Contact factory. Main Gas Inlet Pressure, "w.c. (mbar) 3 Fuel pressure at ratio regulator inlet. High Fire
More information36H Gas Control Product Information
Single Stage 36H Two Stage 36H 36H Gas Control Product Information The 36H combination gas control valve is a versatile multifunction control designed to meet the requirements for use with intermittent
More information2001 Chevrolet Metro LSi ENGINES 1.3L 4-Cylinder - Metro & Firefly (Canadian) Fig. 3: Exploded View Of Timing Belt & Components (Typical)
Fig. 3: Exploded View Of Timing Belt & Components (Typical) Fig. 4: Aligning Timing Marks 6. Loosen the timing belt tensioner bolt and the stud. 7. After pushing up the tensioner plate completely with
More informationEclipse RatioAir Burners
Data 115-1 10/1/07 Eclipse RatioAir Burners Main Specifications - RA0 PARAMETER Maximum input, () at neutral chamber conditions 60Hz Packaged Maximum input, () at neutral chamber conditions 50Hz Packaged
More informationPROFIRE E SERIES TECHNICAL DATA INFORMATION PACKET
PROFIRE E SERIES TECHNICAL DATA INFORMATION PACKET Technical Data Uncontrolled Emissions Configuration (EG, EL, ELG) 8.4-42.0 MM BTU/H NG; 60-300 GPH #2 OIL UL listed with choice of NFPA, CSD-1, GAP, and
More informationInstallation- and maintenance instruction BENTOFLEX ST 108 PL
Installation- and maintenance instruction BENTOFLEX ST 108 PL 1 171 625 30 03-01 178 001 13 DESCRIPTION COMPONENTS 1. Reset button 2. Control box 3. Ignition transformer 4. Ignition cables 5. Nozzle assembly
More informationOIL REGULATORS RFG SERIES FEATURES APPLICATIONS DESCRIPTION INSTALLATION. Bulletin E5301 rev03 02/04/03. Body and valve seat: Shutter seat:
OIL REGULATORS RFG SERIES FEATURES Body and valve seat: AVP Shutter seat: C40 Valve stem: AISI303 Diaphragm: anti-petrol rubbered fabrics Max viscosity: 3 E Max operating pressure: 7 bar Max differential
More informationRatioAir Burners. Model RA0750. Data /31/05. Main Specifications - RA0750
Main Specifications - RA0750 PARAMETER Maximum input, Btu/hr (kw) at neutral chamber conditions. (Natural Gas) 60Hz Packaged 50Hz Packaged Minimum input, Btu/hr (kw) Lower inputs may be achieved. Contact
More informationRatioAir Burners. Model RA1000. Data /31/05. Main Specifications - RA1000
Main Specifications - RA1000 PARAMETER Maximum input, Btu/hr (kw) at neutral chamber conditions. (Natural Gas) 60Hz Packaged Blower 50Hz Packaged Blower Minimum input, Btu/hr (kw) Lower inputs may be achieved.
More informationSER'IICING. CORlJAIR HEATER. the
SER'IICING the CORlJAIR HEATER COPYRIGHT 1959 CHEVROLET MOTOR DIVISION GENERAL MOTORS CORPORA lion PRIMARY IGNITION UNIT: The primary ignition unit can be serviced without removing the combustion blower
More informationMT4000 Series SERVO MOTORS FOR AIR DAMPERS AND BUTTERFLY VALVES
UNIERSL GS LES T4000 Series SERO OTORS FOR IR DPERS ND BUTTERFLY LES PPLITI PRODUT HNDBOOK The T4000, T4001, T4002 and T4003 are servo motors to control and govern air lock of gaseous and liqued fuels.
More informationall combustible gases and fuel oil, extra light gases up to 1 bar, fuel oil up to 40 bar Fuel Connection gases ½, fuel oil ¼
Technical Specification High Velocity Burner Type HV Content 1 Type Designation Code Key Technical Data 3 Deployment and Mode of Operation 4 Basic Construction of the Burner Installation and Startup.1
More informationPRODUCT RANGE
PRODUCT RANGE 2018 www.ecoflam-burners.com CUSTOMIZED BURNERS SOLUTIONS FOR ANY TYPE OF APPLICATION OUR EXPERIENCE Thanks to 45 years of experience in the design and production of burners, Ecoflam offers
More informationINDEX. - Versions and exploded drawing of ECO 20 p pages Versions and exploded drawing of ECO 20 i pages 4-5
INDEX - Versions and exploded drawing of ECO 20 p pages 2-3 - Versions and exploded drawing of ECO 20 i pages 4-5 - Versions and exploded drawing of ECO 20 Fp pages 6-7 - Versions and exploded drawing
More informationGREENOx BT LOW RETURN TEMPERATURE DUAL BT WITH TILED BOILERS. GREENOx BT COND LOW RETURN TEMPERATURE WITH CONDENSER
TECHNICAL MANUAL GREENOx BT LOW RETURN TEMPERATURE DUAL BT WITH TILED BOILERS GREENOx BT COND LOW RETURN TEMPERATURE WITH CONDENSER GREENOx/GREENOx.e/K WITH THREE GAS PASSES DUAL GRX/DUAL GRX.e THREE GAS
More informationTROUBLESHOOTING. 1. What is the model and serial number? If you don t know, how old is it? Give description.
TROUBLESHOOTING There is excellent literature on our website: heatec.com. Look under TEC-NOTE. You will find our newest heater manual. This is full of information (complete with great pictures) on our
More informationInstallation- and maintenance instruction B20KA/K
Installation- and maintenance instruction B20KA/K 1 171 615 27 05-01 178 091 07 DESCRIPTION COMPONENTS 1. Air intake 2. Scale, nozzle assembly 3. Nozzle assembly adjustment 4. Test nipple 5. Ignition cables
More informationCHALLENGER Propane to Natural Gas Instructions
Kit Part Number: CCRKIT02 Kit Includes: - Rating Label - (3) Natural Gas Orifices - T-15 Torx Wrench Recommended Tools: - Phillips-Head Screwdriver - Standard Adjustable Wrenches - Calibrated Combustion
More informationD SERIES TECHNICAL DATA INFORMATION PACKET
D SERIES TECHNICAL DATA INFORMATION PACKET Table of Contents Uncontrolled Emissions DG, DL, DLG Technical Data Sheet...3 Ratings Table...4 Dimension Table...5 Uncontrolled Emissions DM, DMG Technical Data
More informationInstallation- and maintenance instruction B20KA/K
Installation- and maintenance instruction B20KA/K 178 091 07 DISCRIPTION Components 1. Air intake 2. Scale, nozzle assembly 3. Nozzle assembly adjustment 4. Test nipple 5. Ignition cables 6. Schrouded
More informationTECHNICAL DATA LEAFLET GAS. RS/1 Series. One Stage Gas Burners. RS 34/1 MZ kw RS 44/1 MZ kw.
TECHNICAL DATA LEAFLET GAS RS/1 Series One Stage Gas Burners RS 34/1 MZ 7 39 kw RS 44/1 MZ 1 kw www.riello.com One Stage Gas Burners RS/1 Series The RS/1 series of burners covers a firing range from 7
More informationD SERIES TECHNICAL DATA INFORMATION PACKET
D SERIES TECHNICAL DATA INFORMATION PACKET Table of Contents D Series Uncontrolled Emissions DG, DL, DLG Technical Data Sheet...3 Ratings Table...4 Dimension Table...5 D Series Uncontrolled Emissions DM,
More informationFigure 1-1(d) Tft Installation Kit
TRINITY TFT60-399 PARTS LIST For a list of parts that corresponds to the item numbers in the callouts, refer to Table 1-1. Note that some item numbers may appear more than once in the parts list depending
More informationTECHNICAL SERVICE DEPARTMENT Technical Service Bulletin LowNOx Commercial Gas Electronic Spark Ignition Sequence
The Universal TM gas LowNOx series water heaters contain an electronic spark ignition system. The heater is connected to a 120VAC power source required by the transformer. The transformer steps down the
More informationVALUPAK. Packaged gas burners
VALUPAK Packaged gas burners 1-1.5-1 E - i - 11/14 High turndown. Available in 6 sizes. Capacities: 0.007 MBtu/hr - 4 MBtu/hr. Stable and clean combustion. Suitable for UV scanner and flame rod. Natural
More informationActuators. Building Technologies Division
7 802 Actuators SQ72 Electromotoric actuators for air dampers and control valves of oil or gas burners of small to medium capacity. The SQ72... and this Data Sheet are intended for use by OEs which integrate
More informationSTAR SPARE PARTS LIST
STAR SPARE PARTS LIST - January 2005 - WESTEN HOW TO READ THE SPARE PARTS CATALOGUE In the spare part catalogue, after the exploded diagrams, there are the components lists of the boilers; this is the
More informationInstallation- and maintenance instruction BENTOFLEX ST120KAV
Installation- and maintenance instruction BENTOFLEX ST120KAV 1 171 625 61 05-01 178 001 16 DESCRIPTION COMPONENTS 1. Reset button 2. Control box 3. Ignition transformer 4. Ignition cables 5. Nozzle assembly
More informationVQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION
VQ400M SERIES PRODUCT HANDBOOK APPLICATION The VQ400M Series class A safety combination valves are used for control and regulation of gaseous fluids in gas power burners, atmospheric gas boilers, melting
More informationSpecifications of MAXON VALUPAK burners for 50 Hz operation
1-1.5-7 Specifications of MAXON VALUPAK burners for 50 Hz operation Capacity data in kw Gross heating value = 10.9 kwh/m 3 (st), d = 0.6. All figures are for balanced - 0 mbar - duct pressure VALUPAK size
More informationInstallation- and maintenance instruction BENTOFLEX ST133KA/K
Installation- and maintenance instruction BENTOFLEX ST133KA/K 178 007 17 DESCRIPTION Components 1. Reset button 2. Control box 3. Ignition transformer 4. Ignition cables 5. Nozzle assembly 6. Nozzle 7.
More informationVE4000 & VE5000 SERIES
VE4000 & VE5000 SERIES CLASS "A" GAS VALVES PRODUCT HANDBOOK APPLICATION These series class A gas valves are used for control and regulation of gaseous fluids in gas power burners, atmospheric gas boilers,
More informationIntroduction. System Components
The Selectra SERIES 94 is for use with either direct or indirect gas fired units (furnaces, ovens, etc.). The system may be field installed on existing equipment or specified for new equipment installation.
More informationVMH. www. delta-elektrogas.com. Safety shut off valves for gas with hydraulic actuator DN65 DN200 EE
VMH Safety shut off valves for gas with hydraulic actuator DN65 DN200 www. delta-elektrogas.com EE168-0513 VMH Contents Description.. 3 Features.. 3 Functioning and application. 4 Special versions and
More informationInstallation- and maintenance instruction B20K-2
Installation- and maintenance instruction B20K-2 1 171 615 51 05-01 178 017 09 DESCRIPTION COMPONENTS 1. Damper motor 2. Air damper 3. Photocell 4. Scale, nozzle assembly 5. Test nipple 6. Nozzle assembly
More informationSPARE PARTS LIST - July
Versions for CANADA SPARE PARTS LIST - July 2005 - HOW TO READ THE SPARE PARTS CATALOGUE In the spare part catalogue, after the exploded diagrams, there are the components lists of the boilers; this is
More informationBurners. Ribbon linear flame burners AB & ABM (E3010 rev /11/2017)
Burners Ribbon linear flame burners AB & ABM (E3010 rev. 09-14/11/2017) GENERAL WARNINGS: DISPOSAL: ¾ All installation, maintenance, ignition and setting must be performed by qualified staff, respecting
More informationMAINTENANCE SCHEDULE
MAINTENANCE SCHEDULE System Check Item Daily 50 250 500 1000 1500 2000 Grease PTO anti-rotating shields Grease and lubricate ales and PTO bearings Grease fan motor (1 pump) (DO NOT OVER GREASE) Grease/Lube
More informationHoneywell VV, VP, VB & MS SERIES FOR VQ400M CLASS A VALVES PRODUCT HANDBOOK APPLICATION
Honeywell VV, VP, VB & MS SERIES FOR VQ400M CLASS A VALVES PRODUCT HANDBOOK APPLICATION The VV Series class A vent valves are intended to be used in combination with the VQ400M series combination valve.
More informationLight oil burners. Low - high or modulating operation. Installation, use and maintenance instructions
Installation, use and maintenance instructions GB Light oil burners Low - high or modulating operation CODE MODEL 20011027 RL 190/M 3477870 RL 190/M 3477875 RL 190/M 2916051 (12) - 11/2014 CONTENTS INFORMATION
More informationBurners. Metallic free flame burners. EMB (E3004 rev /02/2010)
Burners Metallic free flame burners EMB (E3004 rev. 06-11/02/2010) GENERAL WARNINGS: DISPOSAL: ¾ All installation, maintenance, ignition and setting must be performed by qualified staff, respecting the
More informationInstallation- and maintenance instruction BENTOFLEX ST133K
Installation- and maintenance instruction BENTOFLEX ST133K 171 625 37 07-01 178 004 17 TECHNICAL DATA Type designation ST133K Dimensions B 200 258 ø89 54 237 158 295 Burner tube Length of burner tube Incl.
More informationValves. Rapid opening and closing solenoid valves VMR (E1110 rev /11/2012)
Valves Rapid opening and closing solenoid valves VMR (E1110 rev. 03-19/11/2012) GENERAL WARNINGS: DISPOSAL: ¾ All installation, maintenance, ignition and setting must be performed by qualified staff, respecting
More informationLVDT/HC PILOT BURNER. External raw gas pilot burner
4-22.4-1 LVDT/HC PILOT URNER External raw gas pilot burner Stable pilot flame in combination with MXON IRFLO LV, HC, DELT-TE and COMUSTIFUME burners Rugged design urns natural gas, propane and LPG Suitable
More informationLight oil burners. Low - High or modulating operation. Installation, use and maintenance instructions
Installation, use and maintenance instructions GB Light oil burners Low - High or modulating operation CODE MODEL C9514300 - C9514301 - C9514303 RL 70/M C9515300 - C9515301 - C9515303 RL 100/M C9516300
More informationTECHNICAL SERVICE BULLETIN
INTERNATIONAL, INC. 159 PARIS AVENUE NORTHVALE, NJ 07647 PHONE 201-768-2400 TECHNICAL SERVICE BULLETIN Date: 08/19/05 Number: 2005-03 Subject: KC1000 LOW NOx CONVERSION KIT INSTRUCTIONS Page 1 of 42 1.
More informationInstallation- and maintenance instruction B20KAV/KV
Installation- and maintenance instruction B20KAV/KV 1 171 615 33 05-01 178 035 08 DESCRIPTION COMPONENTS 1. Air intake 2. Scale, nozzle assembly 3. Nozzle assembly adjustment 4. Test nipple 5. Ignition
More informationFig Blast tube 2.Asbestos gasket 3.Flange 4.Body gasket 5. Brake plate. 6. Oil n ozzle 7.Heater 8.Rubber block 9. Transformer 10.
DESCRIPTION Fig. 1 1.Blast tube 2.Asbestos gasket 3.Flange 4.Body gasket 5. Brake plate 6. Oil n ozzle 7.Heater 8.Rubber block 9. Transformer 10. Controller base 11.Motor 2.Photocell 13. Controller 14.
More informationFree flame burners EMB (E3004 rev /02/2015)
Burners Free flame burners EMB (E3004 rev. 08-10/02/2015) GENERAL WARNINGS: DISPOSAL: ¾ All installation, maintenance, ignition and setting must be performed by qualified staff, respecting the norms present
More informationRESIDENTIAL ELECTRONIC IGNITION SYSTEMS
Service Application Manual SAM Chapter 630-153 Section 12 RESIDENTIAL ELECTRONIC IGNITION SYSTEMS by Marcus G. Metoyer, Jr., CMS INTRODUCTION The information contained in this publication is generic in
More informationOil, Gas and Dual Fuel Burners
Oil, Gas and Dual Fuel Burners Burner series 130...150 50, 0 Group 3 Capacity 390-3,500 Table of contents General 1 How to choose a burner Light oil burners Technical data and dimensions 3- PI-diagrams
More informationVQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION
VQ400M SERIES PRODUCT HANDBOOK APPLICATION The VQ400M Series class A safety combination valves are used for control and regulation of gaseous fluids in gas power burners, atmospheric gas boilers, melting
More informationInfo 110 4/98. RatioMatic Burners. RM Series version through 600 Sizes. 750 through 2000 Sizes
Info 110 4/98 RatioMatic Burners RM Series version 1.01 50 through 600 Sizes 750 through 2000 Sizes For Ratiomatic Serial Numbers 95-5500 and Above Version 1.01 7/97 Contents 1.0 Operating Parameters &
More informationInstallation, use and maintenance instructions. Light Oil Burners. RL 70/M - 100/M - 130/M Low - High or Modulating Operation
Installation, use and maintenance instructions Light Oil Burners RL 70/M - 100/M - 130/M Low - High or Modulating Operation C6505053-2916050 (3) - 10/2008 CONTENTS WARNING TECHNICAL DATA...............................page
More information