DRT. Ring Piston Flow Meter. for low/high Viscous Liquids

Similar documents
DOR. Insertion Paddle Wheel Flow Meter/Monitor. for Low Viscous Liquids. Flow range: l/s to l/s. Flow velocity range: 0.

DOR. Insertion Paddle Wheel Flowmeter/Monitor. for low viscous liquids. Flow range: ,300 l/s to ,000 l/s. Flow velocity range: 0.

DOM. Positive Displacement Flowmeter

Flow. Oval Wheel Flowmeter Model DOE

Flow. Oval Wheel Flowmeter Model DON

TWL-Exia. Resistance Thermometers according to DIN. Ignition Protection Exia. Pt 100-sensor class A respectively class B

MAN-P. Diaphragm Pressure Gauges. according to EN for Stringent Demands

Model: TUR with transmitter. Output: pulses, 0-20 ma, 4-20 ma or 0-10 V, LED display, pointer indication, switching output

DOR. Insertion Paddle Wheel Flow Meter / Monitor. for Low Viscosity Liquids

PSR/PSE Paddle Flow Monitor for Liquids Switching ranges: L/min water p max : 250 bar, t max

Vortex Flow Meter Model DVH

NGS. Dual-Magnet Float Switch. Pressure: up to 25 bar. Density: > 0.7 kg/dm 3. High switch capacity. Material: stainless steel 1.

Paddle Flow Monitor Model PSR/PSE

Vortex Flowmeter Model DVE

DVH. Vortex Flowmeter. Measuring range: Nm³/h. Accuracy: ± 0,7% of reading (liquids) ± 1% of reading (gases and steam) p max

TUR. Turbine Wheel Flowmeter. plastic version for liquids. Measuring ranges: ,0 m 3 /h water. ± 1% of full scale

QUALITY INDUSTRIAL FLOWMETERS

NCP/NCB/NCS. Magnetic Float Switches. for Liquids

MMA. Insertion Resistance Thermometers. with, or without transmitter. OEconomically-priced O thermometers with optional plug-on display

OM SERIES OVAL GEAR METERS. OM SERIES Oval Gear Meters

RCM. Direct Reading Flowmeter. for Liquids or Gases

SM Series. High Pressure - All-Metal Flowmeter and Switch

TUR. Turbine Wheel Flowmeter. Plastic Model for Liquids. Measuring Ranges: GPM or GPM (Water)

TER. Thermostats for Industrial Applications. Switching range: C to C. Housing material: aluminium. Capillary tube: copper

DOR Insertion Paddle Wheel Flowmeter

OM004, OM006 & OM008 Oval Gear Meter

Positive displacement flowmeter for continuous flow measurement

Turbine Wheel Flow Meter

High Precision Turbine Wheel Flow Meter for Liquids

Accessories for Pressure Gauges

MX-SERIES OVAL GEAR FLOW METERS

QUALITY INDUSTRIAL FLOWMETERS

Compressed Air-Supply Meter

DON. Oval Gear Flowmeter

Type 2712 (8630) Continuous TopControl System. General data Compatibility Materials of wetted parts Body Rotor Shaft Seal

macnaught flow measurement

DWU. Paddle Bellows Flow Monitor. for liquids. 1-5 l/min m 3 /h water OAccuracy: ±3... ±5% of full scale OConnection: O

OMP POSITIVE DISPLACEMENT FLOWMETERS

EPS / UMF2. Magnetic Inductive Flowmeter for Conductive Liquids

macnaught flow measurement

Trimec Flow Products Pty. Ltd. Tel : /51 Kalman Drive, Fax : Effective : August 2013

PSF50 Paddle flow switch

TTM. Sheath Thermocouples. Flexible sheathed cable C. Sheath diameter from 0.5 mm. O O Sheath in stainless steel 1.

9900 Series Oval Flowmeter/Transmitter with SMART METER MANAGER

Industrial OG meter series IOG Inline and flanged oval gear meter

Differential pressure gauges with Bourdon tube

Operating Instructions for Oval Wheel Flowmeter. Model: DOC

Oscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids

Operating Instructions for Oval Wheel Flowmeter. Model: DOE

macnaught flow measurement

KDM ARMORED FLOW METER & SWITCH

Flow Sensors & Instruments

BI-DIRECTIONAL INSERTION FLOW TRANSDUCER

MULTIPULSE PISTON POSITIVE DISPLACEMENT FLOWMETER

MULTIPULSE SAP SUPER ACID PROOF POSITIVE DISPLACEMENT FLOWMETER

PRECISION METERS. Tel: / Int'l: Fax: / Int'l: Springer Pumps, LLC Telford, PA 18969

RCM - Direct Reading Flowmeters

Flow meter Type Recordall (RCDL)

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

OVAL GEAR Medium capacity positive displacement flowmeters

QUALITY INDUSTRIAL FLOWMETERS

ProFlow TO BE REALLY SURE. Vane Meters. Experience in flow measurement. Introduction

Operating Instructions for Oval Gear Flow Meter. Model: DON-...Lx/Hx/Rx/Dx/Gx/Kx/Bx/Zx/M4

Contact Device. for Pressure Gauges

COVOL. Operating Data. Areas of Application. Measuring Ranges. Method of Operation. Fields of operation. Features. Installation information

DPT TARGET TYPE FLOWMETERS

POSITIVE DISPLACEMENT FLOW METERS

Turbine flowmeters Series TM

Shipbuilding solutions

G2 Industrial Grade Meters

POSITIVE DISPLACEMENT FLOW METERS

Metal tube variable area flowmeter for gases, liquids and steam

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

OVAL GEAR Medium capacity positive displacement flowmeter

The new STx chain hoist NEW. Sophisticated technology prepared for the future

RUN ACCUM. TOTAL STOP BAT LOW HIGH

Macnaught Fuel & Oil Flow Meters

DW PADDLE-BELLOWS FLOWMETER & SWITCH

OMP Positive Displacement Flowmeters

Mass Flow Meter Model: MAS. Design

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

KEL. Heavy Duty Differential Pressure Flowmeters

BI-DIRECTIONAL INSERTION METER

DIAPHRAGM PRESSURE CYLINDERS

INSERTION flow sensor for continuous flow measurement

VZ-01. Features. Oil Counter for Light to Heavy Fuel Oil. Description: Application: / Mounting on pressure or suction side

DW PADDLE-BELLOWS FLOWMETER & SWITCH

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Operating Instructions for Torsion Paddle Flow Meter / Monitor. Model: DPT-...

Technical Data. BiRotor Plus Positive Displacement Meter

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Fork through-beam sensors

NTD. Volumetric flow meters with IP-55 or EExd protection. Nuevas Técnicas de Dispersión, S.L.

BFS-10-O G1/4: BFS-10-O G1/2: BFS-10-O G1: Contact rating: BFS-10-O G1/4

Operating Instructions for Viscosity Compensated Flow Meter / Monitor. Model: VKM

Operating Instruction for Flowmonitor. Model: DF-WM

3" Steel Model E3. We put you first. And keep you ahead.

MULTIPULSE PISTON POSITIVE DISPLACEMENT FLOWMETER

MX06 - MX100 OVAL GEAR FLOWMETER SERIES

M-61-F. Fixed Set Point Flow Switch. Description. Operating Principle. Application Examples.

Transcription:

Ring Piston Flow Meter for low/high Viscous Liquids measuring monitoring analysing DRT Measuring range: 0.2... 10 L/min to 12... 330 L/min Viscosity range: low viscous to high viscous liquids Accuracy: ± 0.2 %... 1 % of reading p max : 350 bar; t max : +150 C Connection: G½... G2 female, ½" NPT... 2" NPT female, DIN flanges DN 15... DN 50, ANSI flanges ½"... 2" : Stainless steel, aluminium Output: Pulses, LCD display, 4... 20 ma, batching, totalising 1/05-2011 KOBOLD companies worldwide: ARGENTINA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHILE, CHINA, COLUMBIA, CZECHIA, DOMINICAN REPUBLIC, EGYPT, FRANCE, GERMANY, GREAT BRITAIN, HUNGARY, INDIA, INDO- NESIA, ITALY, MALAYSIA, MEXICO, NETHERLANDS, PERU, POLAND, ROMANIA, SINGAPORE, SOUTH KOREA, SPAIN, SWITZER-LAND, TAIWAN, THAILAND, TUNISIA, USA, VIETNAM KOBOLD Messring GmbH Nordring 22-24 D-65719 Hofheim/Ts. Head Office: +49(0)6192 299-0 +49(0)6192 23398 info.de@kobold.com www.kobold.com 1

Description The Kobold model DRT fl owmeters utilise the widely accepted oscillating piston design principle with the performance enhanced by the use of modern engineering materials to provide a cost effective and reliable solution for a wide range of industrial fl ow measurement applications. This fl owmeter utilises the oscillating piston principle, where the passage of liquid causes a piston to oscillate smoothly in a circular motion inside a round measuring chamber. Each piston cycle displaces a known volume of liquid from the inlet port to the outlet port. Small high energy magnets located within the piston activate the integral electronics which in turn generate high resolution pulse outputs suitable for remote fl ow integration instruments, computers and PLC's. This simple and robust design offers the advantage of only one moving part with both high resolution NPN Hall Effect open collector and reed switch outputs as standard. As each piston oscillating cycle passes a known volume of liquid, the inherent repeatability of the positive displacement fl owmeter makes it particularly suited to batching and dispensing duties. Positive displacement fl owmeters are an inexpensive means to accurately meter high viscosity clean liquids as high as 1 million centipoise however, the appropriate meter must be sized so that the pressure drop across the primary measuring elements (oscillating or oval rotor), does not exceed the maximum capability of either. The oscillating piston meter can withstand 2.8 bar differential pressure making it more suitable to high viscosity liquids, the oval wheel is limited to 1 bar differential due to the pressure imposed on the rotor shafts. Applications Common applications range from non-conductive low viscosity solvents through to extremely viscous lubricants, chemicals and food bases. Application fl exibility is further enhanced as meter performance is independent of fl ow profi le eliminating the restrictive need for straight pipe runs required with most alternate metering technologies. The DRT has no stagnate chambers to harbor contaminants. There is no restriction on mounting orientation and the fl owmeter may be operated under vacuum fl ow, pumped fl ow or gravity fl ow conditions. The aluminium model is suitable for metering petroleum products, diesel, fuel oil, lubrication oil, hydraulic oil, kerosene, gasoline, alcohol, solvents, laquers and grease. Typical applications for stainless steel model include chemical and allied products, pharmaceuticals, petroleum, LPG, deionised water, container fi lling machines, fuel additives, bitumen, paint, synthetic rubber, latex, detergent and soap, pigments. The high pressure stainless steel model applications include hydraulics, lube oil, mercaptan, petroleum, deionised water, resins, MEK, ethylene oxide, oil and gas industry, injection of chemical and bonding solution Technical Details s: Body: Piston: Partition : Stainless steel 1.4404 (316L) or aluminium CFT - Carbon Filled PTFE (standard) or PEEK Stainless steel 1.4404 (316L) or ceramic (for abrasive or low lubricity fl uids such as water, road marking paints etc.) Oscillating Piston Principle Liquid Entering the Measuring Chamber Liquid in Transition Liquid Leaving the Measuring Chamber Inlet Port Outlet Port 2 www.kobold.com 1/ 05-2011

Seals: FPM (standard): -15 +200 C EPR (Ethylene Propylene Rubber): -20 +150 C, for ketones only PTFE encapsulated FPM: -20 +150 C NBR: -65 +100 C Cover (for pulse output): Glass reinforced nylon, st. steel (options NE, QE) Accuracy (at 3 cp): ±1 % of reading (DRT-xx4) ± 0.5 % of reading (for all other models/sizes) ± 0.2 % of reading (with ZOD-Z3 linearisation) Viscosity range: (see graphs on page 5 for higher viscosities with fl ow de-rating) Repeatability: ± 0.03% Temperature range: -20 +80 C for options Z and B and -20 +120 C for pulse output for options Z and B with cooling fi n and +150 C only with piston material PEEK and NPN pulse output Pressure drop: see fl ow de-rating graph Supply voltage: see electrical output specifi cations, electronics comparison table and ZOD datasheet Electronic features: see electronics comparison table or ZOD datasheet Electrical output: see page 4 Output frequency at max. velocity: 67... 110 Hz (Hall effect pulse output), 14... 33 Hz (Reed switch pulse output) Wiring (standard): 5 core, screened cable Transmission distance: 1000 meters maximum, without integrated electronics Cable entry: see order details Protection Class: IP 66/67 Straight pipe runs requirement: none Mounting: universal (bi-directional fl ow) Maximum Pressure (threaded version): see table below Output pulse resolution: ATEX-approval (option Z4): (options NE, QE): Approx. shipping weights (threaded meters only): Recommended fi lters: see table below II 2G EEx ia IIB T4 (-20 C Ta +60 C) II 2G Ex d IIB T6 (-20 C Ta +70 C) II 2G Ex d IIB T4 (-20 C Ta +120 C) I M2 Ex d IMb (st. steel models only) see table below 150 microns (100 mesh) minimum Electrical Output Specifications Hall Effect Sensor Pulse Output (N1) The Hall Effect Sensor is a high resolution solid state 3 wire device providing an un-sourced, open collector, NPN transistor output. The term "un-sourced" means that no voltage is applied to the output from within the fl owmeter, it must be pulled to a 'high' or 'on' state by between 5...24V DC supplied from an external source, typically the receiving instrument. The pulse output between signal and -0V is a voltage square wave with the high level being the DC voltage available at the open collector and the low level being -0V. The receiving instrument must incorporate a pull up resistor (typically greater than 10K ohms in most instruments ) which ties the open collector to the available DC voltage level when the Hall sensor is not energized. When energized the open collector output is pulled to ground through the emitter (-0V). Power supply: max. 5...24 V DC, max. 20 ma These pulses are suited to small volume batching applications requiring high levels of repeatability. The square wave pulses are unevenly spaced due to the cyclic motion of the piston, but like the reed switch each pulse is representative of an equal volume. 1/05-2011 Max. Pressure (threaded meters)/output pulse resolution/approx. shipping weights (threaded meters) Size Model Maximum pressure (bar) Measuring range (pulses/litre) Weight (kg) DRT-A DRT-S DRT-H (L/min) Reed Switch www.kobold.com Hall Effect Quadrature Hall Effect DRT-S/H DRT-xx4* 30 100 350 0.2... 10 200 400 200 2.3/3.2 1.1 DRT-xx6 60 60 150 2... 50 20 100 20 3.1/4.8 1.6 DRT-xx8 30 60 150 4... 140 7.3 44 7.3 6.5/8.0 3.3 DRT-xx9 20 30-12... 330 2.5 20 2.5 10/12.2 4.6 with fl anges, max. pressure rating as above or as per fl ange pressure rating, whichever is lower *at a time, only one of the three sub ranges 0.2... 1.7 LPM, 1.7... 7 LPM, 5... 10 LPM may be used (diff. K-factors for each range) DRT-A 3

Reed Switch Pulse Output (R0) The reed switch output is a two wire normally open SPST voltage free contact ideal for installations without power or for use in hazardous area locations (simple apparatus) when Intrinsically Safe (I.S.) philosophy is adopted. Note: when using the reed switch output the liquid temperature must not change at a rate greater than 10 ºC per minute. In general the reed switch life will exceed 2 billion actuations when switching less than 5V DC at10ma. Power supply: max. 30 V DC, 200 ma. Quadrature Hall Effect Pulse Output (Q2) Two Hall Effect sensors arranged to give separate outputs out of phase with one another. The quadrature output is typically suited to ensure output signal integrity or to measure bi-directional fl ow. Power supply: max. 8-24 V DC, max. 20 ma. Viscosity Effects on DRT Pulse Output (K-factor) Each DRT fl owmeter is calibrated at the factory using Diesel as the test media. When metering higher viscosity liquids the meter K-factor will be a more positive number than that of Diesel at 2.55 cst viscosity. To calculate the approximate relative K-factor for other liquid viscosities apply the approximate K-factor multiplier from the graph below as per the following example: K-factor when used with liquid 1cp = 101.255 K-factor when used with liquid 12 cst = 104.293 (101.255 x 1.030). This is a generic Output K factor multiplier chart as based on water at 1 cst, for reference only. Always use the Calibration Certifi cate K factor as the default setting unless otherwise specifi ed. The factory K factor is suitable for most applications without any need for correction. 16 Electronic with LCD display Function Model --Z1..Z3..Z5..B1 Power source dual totalizer rate totalizer rate totalizer batch controller battery-powered yes yes yes no external (drives output, backlighting) 8-24 V DC 8-24 V DC 8-24 V DC 12-24 V DC LCD display -line 1 / no. of digits 7.5 mm/5 9 mm/8 17 mm/6 9 mm/8 -line 2 / no. of digits 3.6 mm/8 7 mm/8 selectable units yes yes yes yes decimal point yes yes yes yes subscripts displayed yes yes yes yes accumulative total yes yes yes yes resettable total yes yes yes no linearisation no yes no no rate display no yes yes no backlighting no no yes no Input type un-powered sensors see ZOD datasheet powered sensors see ZOD datasheet Outputs 4-20 ma (750 Ω) no yes no no high/low fl ow alarm no NPN/PNP NPN no batch end & control no no no NPN/PNP pulse outputs NPN/PNP NPN/PNP NPN NPN/PNP 2 x SPDT relays no optional* no optional* Installation IP 66/67 yes yes yes yes cable entries 1 x gland (meter mount) 2 x glands (remote) 3 x M 20 3 x M 16 3 x M 20 intrinsic safe (option) no yes no no mounting meter mount, wall, pipe or panel mounting temperature range -20... +80 C (Option: -20... +120 C) *replaces solid state outputs 14 12 Effective viscosity (cst) 10 8 6 4 2 0 1.000 1.005 1.010 1.015 1.020 1.025 1.030 1.035 Output K-factor multiplier 4 www.kobold.com 1/ 05-2011

Viscosity Multiplier Factor Curve for DRT Flowmeter Maximum Flow Capacity 1 000 000 The maximum pressure drop across DRT fl owmeters must not exceed 280kpa (40psig). To determine the maximum fl ow capacity of a DRT fl owmeter used on a liquid with viscosity greater then 1cp, divide 280kpa (40psig) by the Multiplier factor derived from this curve. Take this new calculated pressure drop fi gure and determine the meter maximum fl ow capacity by refering to the DRT pressure drop curves for water (1cp). E. G. For a 1000cp liquid the factor is 6. The new calculated maximum pressure drop is therefore 47kpa (7psig). If the meter is a DRT-xx8 the maximum fl ow is approx 73% of range, i. e. 0,73 x 140 102 L/min (27 USGPM). Viscosities above which the max. published DRT fl ow rates must be derated are: DRT-xx4... 5000cp DRT-xx8... 250cp DRT-xx6... 2500cp DRT-xx9... 100cp 100 000 10 000 1000 100 10 Viscosity (cp) 1 6 11 16 21 26 31 36 41 46 51 56 61 Multiplier factor (ref. DRT pressure drop curve for water) To determine the pressure loss of a liquid with a viscosity greater than 1cP, use the above graph to derive the multiplier factor to apply to the DRT pressure drop curves for water at 1cP. 1 Pressure drop at 1 cp Pressure drop (Kpa) 120 100 80 60 40 20 0 DRT-xx4 DRT-xx9 DRT-xx8 DRT-xx6 0 10 20 30 40 50 60 70 80 90 100 110 % of Maximum Flow DRT-xx4 DRT-xx6 DRT-xx8 DRT-xx9 1/05-2011 www.kobold.com 5

Spare parts of a meter with pulse output: 8 9 11 7 6 5 Spare parts: 1 Piston 2 Partition 3 Manifold bearing 4 Manifold O-ring 5 Pulse output board 6 Output board screw 7 Terminal cover 8 Terminal cover screw 9 Terminal cover O-ring 10 Body 11 Body screw 12 Manifold (refer factory for fl anged or other non-threaded manifolds) 10 1 3 4 2 12 6 www.kobold.com 1/ 05-2011

Order Details Thread Connection (Example: DRT-S G9 2 S F 3 M N1) Range [L/min] 0.2... 10 2... 50 4... 140 12... 330 Model/ Housing Connection G6 = G 1 DRT-A = aluminium N6 = 1" NPT DRT-S = st. steel DRT-H 1) = st. steel, high pressure G4 = G ½ N4 = ½" NPT G8 = G 1 ½ N8 = 1 ½" NPT G9 = G 2 N9 = 2" NPT Piston 2 = PEEK 3 = CFT - Carbon Filled PTFE (stdd.) Partition S = st. steel (standard) C = Ceramic (for abrasive or low lubricity fl uids) O-Ring F = FPM (standard) N = NBR (max. 100 C) P = PTFE encapsulated FPM N = EPR Temperature Limits Cable Entry Electronics 1 = -20... +60 C 2 2) = +60... +120 C N1, Q2) +60... +80 C Z1...Z5, B1) 3 2) = +120... +150 C (only possible with piston material PEEK and NPN pulse output) 5 2)3) = +80... +120 C Z1...Z5, B1) M = M20x1.5 N = ½" NPT 1) not for DRT-Hx9...; 2)3) max. temperature limited to +100 C when choosing NBR as O-ring material ; 3) cooling fi n fi tted to integral instruments 4) should be chosen when using DRT in instrinsically safe circuits as "simple apparatus". R0 4) = Reed switch pulse output N1 = Hall sensor (NPN)/ reed switch pulse output NE = Hall sensor (NPN)/ reed switch pulse output + ATEX (Exd) Q2 = Quad Hall sensor 2 phased outputs (NPN) QE = Quad Hall sensor 2 phased outputs (NPN) + ATEX (Exd) Z1 = dual LCD totaliser, pulse output (ZOD-Z1) Z3 = LCD totaliser, rate, outputs: 4-20 ma, alarm, pulse (ZOD-Z3) Z4 = Electronics "Z3" + ATEX (Exi) Z5 = dual LCD totaliser/ rate, outputs: alarm, pulse (ZOD-Z5) B1 = LCD batch controller, totaliser, pulse output (ZOD-B1) Order Details Flange Connection (Example: DRT-A F6 3S F 2 M Z 1) Range [L/min] Model/ Housing Connection Piston Partition O-Ring Temperature Limits Cable Entry Electronics 1/05-2011 0.2... 10 2... 50 4... 140 12... 330 DRT-A = aluminium DRT-S = st. steel F4 = DN 15/PN16 A4 = ½" ANSI - 150RF B4 = ½" ANSI - 300RF F6 = DN 25/PN16 A6 = 1" ANSI - 150RF B6 = 1" ANSI - 2 = PEEK 300RF F8 = DN 40/PN16 A8 = 1 ½" ANSI - 150RF B8 = 1 ½" ANSI - 300RF F9 = DN 50/PN16 A9 = 2" ANSI - 150RF B9 = 2" ANSI - 300RF 3 = CFT - Carbon Filled PTFE (stdd.) S = st. steel (stdd.) C = Ceramic (for abrasive or low lubricity fl uids) F = FPM (standard) N = NBR (max. 100 C) P = PTFE encapsulated FPM N = EPR www.kobold.com 1 = -20... +60 C 2 1) = +60... +120 C N1, Q2) +60... +80 C Z1...Z5, B1) 3 1) = +120... +150 C (only possible with piston material PEEK and NPN pulse output) 5 1)2) = +80... +120 C Z1...Z5, B1) M = M20x1.5 N = ½" NPT R0 3) = Reed switch pulse output N1 = Hall sensor (NPN)/ reed switch pulse output NE = Hall sensor (NPN)/ reed switch pulse ouput + ATEX (Exd) Q2 = Quad Hall sensor 2 phased outputs (NPN) QE = Quad Hall sensor 2 phased outputs (NPN + ATEX (Exd) Z1 = dual LCD totaliser, pulse output (ZOD-Z1) Z3 = LCD totaliser, rate, outputs: 4-20 ma, alarm, pulse (ZOD-Z3) Z4 = Electronics "Z3" + ATEX (Exi) Z5 = dual LCD-totaliser/ rate, outputs: alarm, pulse (ZOD-Z5) B1 = LCD batch controller, totaliser, pulse output (ZOD-B1) 1)2) max. temperature limited to +100 C when choosing NBR as O-ring material; 2) cooling fi n fi tted to integral instruments; 3) should be chosen when using DRT in instrinsically safe circuits as "simple apparatus". 7

Dimensions ØC Z3/B1 Z5 Z1 Cover B ØD A Model A [mm] D [mm] C [mm] B [mm] Flange Thread Flange Thread Integral Electronics DIN PN16 ANSI 150 ANSI 300 G NPT DIN PN16 ANSI 150 ANSI 300 G NPT Cover Z1 Z3/B1 Z5 DRT-xx4 140 132 145 100 100 95 89 95 - - 75 111 134 143 147 DRT-xx6 165 152 170 117 117 115 108 124 - - 98 147 170 179 183 DRT-xx8 235 224 239 175 175 150 127 156 - - 140 169 192 201 205 DRT-xx9 258 253 268 202 202 165 152 165 - - 166 204 225 234 238 8 www.kobold.com 1/ 05-2011