INSTALLATION INSTRUCTIONS

Similar documents
INSTALLATION INSTRUCTIONS

COYOTE 9.5" x 19" (292 mm x 509 mm) Cross-Connect Dome Closure

COYOTE 28" GLC (Ground Level Closure) Complete Assembly Installation

Environmental Distribution Center (EDC-06P-NH)

Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED product before application.

COYOTE Dome Closure 9.5" x 28" with Transition Tray for High Density Splice Applications

INSTALLATION INSTRUCTIONS

JANUARY 2015 NOMENCLATURE. TOOLS REQUIRED 3/8" & 7/16" Can wrench or socket 1/4 Nut driver or screwdriver Snips Fiber optic cable opening tools

COYOTE STP (Service Termination Point)

FIBER CONNECTOR SAFETY WARNINGS

CS Fiber Optic Splice Case. Instruction

COYOTE Dome Closure 6.5" x 22" Kits. COYOTE Dome Closure 6.5" x 22" for Buffer Tube Applications. Includes: (2) Grommets, (1) Buffer

COYOTE STP (Service Termination Point)

Instructions for Use - Opt-X 1000i Enclosure

Fiber optic splice closure

MARCH COYOTE 9.5 x 19 (292 mm x 509 mm) Terminal Dome Closure Kits

COYOTE 9.5" x 19" (292 mm x 509 mm) Dome Closure

INSTALLATION INSTRUCTIONS

Splice Trays. features and benefits. specifications. A LANscape. Solutions Product. Splice Capacity

COYOTE Terminal Dome Closure 6.5" x 22"

Opticom Rack Mount Fiber Enclosures

Pretium Wall-Mountable Housing (PWH-02P/-04P/- 06P/-12P and FZB-02P-JB)

COYOTE Dome Cross-Connect Closure 6-1/2" x 22"

OFE-CLS-Type Outside Plant (OSP) Fiber Optic Closures Instructions

LightLink Fiber Optic Splice Trays

Instructions for Use - Opt-X Ultra Enclosure Directives Enceintes Opt-X Ultra MC Instrucciones de Uso Caja Opt-X Ultra MR

Opti-Guard Splice Enclosure

LSS1U-144/7 FIBER OPTIC SPLICE SHELF INSTALLATION GENERAL CUSTOMER SERVICES REFERENCES TOOLS REQUIRED

COYOTE LCC (Low Count Closure)

COYOTE CLOSURE ADOBE SERIES FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 22" 8.5" x 22" (152.4 mm x mm mm x 558.

3000SC Fiber Optic Splice Closure

OFS LSS1U-864/ Instruction Sheet Fiber Optic Comcode: Splice Shelf Installation

Mini-OTE 400. Mini-OTE 400. Content 1 General 1.1 General product information 1.2 Cable types 1.3 Symbols in this guide.

THE SB01 SPLICE ENCLOSURE NOW INCLUDES A LID GASKET THAT DOES NOT REQUIRE RTV APPLICATION.

Fiber Splice Panel Rack Mount User Manual

Section 3 FIBERLIGN Closure Series

Features: Use the selection chart below to choose the Splice Case and splice tray organizer which meet the requirements for your application.

8400 Series Fiber Distribution System

Fiber Optic Splice Module

OFS 400A FIBER OPTIC INTERCONNECT Instruction Sheet UNIT (FOIU) Comcode INSTALLATION

Fiber Connector Shelf (CCS)

OFS Fitel LST1U-072/7 and LSTLW Instruction Sheet (LaserWave) Fiber Optic Comcode: Termination Shelf Installation

SYSTIMAX G2 4U Fixed Rear Access Combination Shelf Instructions

CommScope MULTILAYERED 289-TYPE INSTALLATION INSTRUCTIONS

SJOF-BS604A Fiber Optic Splice Closure User Manual Rev.0

TOYOTA VENZA 2009 TRAILER WIRE HARNESS Procedure

FlexJet - Flex Cable Replacement

3M Fiber Dome Closure FDC 10

OPTICAL FIBER CLOSURE

SPC-P Smart Power Connection with Temperature Monitoring Transmitter Pipe Mounted Installation Instructions

FIST-GSS2 FIST-GSS3. Fist Generic Splicing Shelf. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails

Universal Splice Tray Installation Instructions

Chengdu Qianhong Communication Co., Ltd. Fiber Optic Splice Closure. GJS03-M8AX-JX-144D-Mechnical Sealing Way.

TOYOTA VENZA 2009 TRAILER WIRE HARNESS Procedure

C A Heating Cable Gland Kit Installation Instructions

Multilink s Family of Wall Mount Enclosures

FL2000 Termination/Splice Panels User Manual

Loose Parts Note: Determine the left and right sides of the machine from the normal operating position.

FOSC-400D5 INSTALLATION INSTRUCTION. Fibre Optic Splice Closure with integrated organiser system

FOSC-400A4 INSTALLATION INSTRUCTION

Assault Air Bike Assembly Instructions

A935 OWNER'S MANUAL ASSEMBLY INSTRUCTIONS

235/245400, , 28N

AUXILIARY BATTERY BOX INSTALLATION INSTRUCTIONS

How to remove and replace the Foonf/Fllo fabric

C A HEATING CABLE GLAND KIT INSTALLATION INSTRUCTIONS

*CROSSBAR SPREAD Your crossbar spread is the distance between the crossbars. This hidden switch enables safe mounting outside the towers.

w w w. h d o n l i n e s h o p. d e CRUISE CONTROL KIT GENERAL INSTALLATION -J04064 REV Kit Number Models Additional Parts Required

STEERING SYSTEM - MANUAL RACK & PINION

Installation Instructions 1812 Folder Disk Clutch Retrofit Kit Martin Yale #WRA

Assembly Instructions

FIST-GSS2. Fist Generic Splicing Shelf MK2. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails

/ CABLE TIES & WIRE FASTENERS /

CONTENTS. This Product is Certified by CANADIAN STANDARDS ASSOCIATION and Bears the Mark:

Instructions for Wire Mesh Pulling Grips on Outside Plant and Indoor/Outdoor Fiber Optic Cable Best Practices

Section 1 COYOTE Closure Series

JBS-100-STB Single Entry Power Connection with Junction Box Installation Instructions

Loose Components. VetPro 5000 Wall / Cabinet Mount Installation. Applies to Models:

92-00 Civic/ Integra/ Del Sol/ Accord/ CRX

PLEASE READ THIS INSTRUCTIONS CAREFULLY, BEFORE YOU START INSTALLATION

M14 AUTOMOTIVE SPARK PLUGS AND WIRES CONVERSION KIT INSTALLATION INSTRUCTIONS

VHM-P (Non-Locking) and VHM-PL (Locking) Variable Height Arm with Slide-In Mounting Plate

BETTIS ACTUATOR & CONTROLS SERVICE INSTRUCTIONS FIELD CONVERSION OF SPRING CARTRIDGE FAIL DIRECTION CLOCKWISE TO COUNTER-CLOCKWISE OR THE INVERSE

SPEC SHEET. OmniReach FTTX Solutions. NEMA Fiber Demarcation Box (FDB) Features

LPC Series Fiber Panel 12/24 Fiber Rack-Mount Enclosure Installation Instructions

SUT-450-I ASSEMBLY REQUIREMENTS

HelaGuard. Non-Metallic Conduit & Fittings

***THE OWNER'S MANUAL MUST BE GIVEN TO THE END USE CUSTOMER AFTER COMPLETING THE INSTALLATION.***

ThermoLite 110W-330W Solar Panel Installation Instructions

JBM-100-STB NEMA 4X-rated connection kit Installation Instructions

Instructions for Preparing AFL OPTICAL GROUND WIRE CABLE (HEXACORE CABLE DESIGNS)

THE SB01 SPLICE ENCLOSURE NOW INCLUDES A LID GASKET THAT DOES NOT REQUIRE RTV APPLICATION.

LEXUS GS 350/450h ILLUMINATED DOOR SILLS Preparation

SYSTIMAX 360 ipatch G2 Fiber Ultra High Density (UHD) Shelf, LC InstaPATCH Distribution Panel Instructions

HD30 & HDP20 Series. Contents. Mounting 88. Overview. Dimensions 80. How To Instructions Part Numbering System 81. Configurations 82-83

FOSCHF Horizontal Fiber Optic Splice Closure

Patching & Splicing Shelf. 4.2 Side cable termination directly on the shelf using cable termination plate. IFC cable/break-out cable

HS6B Series Subminiature Interlock Switch

Cable Management Solutions. HelaGuard. Non-Metallic Conduits and Fittings

69-74 VW Beetle IRS Rear Kit Part No

Transcription:

TABLE OF CONTENTS GENERAL...2 SPECIFICATIONS...2 PACKAGE CONTENTS...2 PACKAGE CONTENTS: ACCESSORIES...3 REQUIRED TOOLS...3 ADD-ON COMPONENTS...3 CLOSURE MOUNTING...3 LOCK AND UNLOCK EXTERIOR DOOR...3 CABLE PREPARATION...4 CABLE INSTALLATION...4 PIGTAIL INSTALLATION...5 COMPRESSION FITTING INSTALLATION...5 DISASSEMBLE COMPRESSION FITTING CABLE REPLACEMENT...6 SPLICING...6 ADAPTER PLATE INSTALLATION...7 DISTRIBUTION CABLE INSTALLATION PLUG AND PLAY...7 DISTRIBUTION CABLE INSTALLATION SPLICE ONLY...8 1

GENERAL The OptiNID 500 Optical Demarcation Closure (OPN-500) is designed for installation in either indoor or outdoor environments. The closure is equipped with an integrated splice tray which will hold up to six single fusion splices. The closure will house one LGX 118 adapter plate allowing for up to six bulkhead connections. The OPN-500 may be either wall or pole mounted and the small form factor makes it ideal for FTTx demarcation applications. SPECIFICATIONS Parameter Dielectric Strength Value Minimum 2500Vrms for 1 minute High Temperature Storage/Mold Stress F ( C) 14 Days at 159 (70.55) Temperature Cycling with Humidity F ( C) Impact Test F ( C) Drop Test F ( C) Rain UV Resistance (Days Exposed) Salt Fog (Days Exposed) Flammability Chemical Resistance 30 Days at 100 F and 95% RH Material 150 Days Cycling from 40-140 (4.44-60) with 95% RH -40 (-40), 5ft/lbs on all external surfaces -40 (-40), 5ft onto concrete surface four times 24 hours at 10 psi 60 per ASTM-G26-84 60 per ASTM-BLL-90 UL95-5V Resists chipping and/or cracking when subjected to house paint, wasp spray, sulfuric acid, kerosene and sodium hydroxide UL Listed Flame Retardant Thermoplastic Alloy Dimensions (H x W x D) in. (cm) 6.3 x 7.8 x 2.0 (15.7 x 19.7 x 5.0) Cable Entrance in. (cm) diameter - Input 1 x 3/4" NPT (1.130"); 2 x 1/2" NPT (0.875") Covers Standard, molded-in snap finger and "F" termination PACKAGE CONTENTS A. OPN-500 Optical Demarcation Closure B. Adapter Plate (Optional) 2

PACKAGE CONTENTS: ACCESSORIES Single Fusion Splice Chip Kit Security Cover Mounting Screws REQUIRED TOOLS 216-Style Socket Tool Flat head Screwdriver ADD-ON COMPONENTS Compression Fitting Kit Splice Chip Kit Pigtail Kit CLOSURE MOUNTING 1. Using local engineering practices, determine the mounting position of the closure on the wall. 2. Using the provided mounting screws, secure the closure to the wall. Note: When mounting to a pole, the two mounting tabs located on the back of the closure are designed to accept a Del Tec strap. LOCK AND UNLOCK EXTERIOR DOOR 1. Using a standard 216 style tool, or similar, loosen the screw located on the right side of the closure door. Do not remove this screw from the closure doors. 2. Press the tab located above the hex screw in to open the closure. (Figure 1) Note: A pad lock, not provided, may be utilized if additional security is desired. Tab Screw Figure 1 3

CABLE PREPARATION Caution: Fiber optic cable is susceptible to damage from excessive bending, pulling or crushing forces. At every stage of the installation process ensure that the loose buffer tubes or ribbon fibers are free from unintentional cuts, knick or bends to avoid potential fiber damage. 1. Mark the cable to have a 26" (66.0cm) opening. 2. Use accepted local practice to remove the cable sheath. Note: If grounding is required, mark and cut the tone wire to 6" (15.3cm) from the sheath opening. 3. Use wire cutters to cut the central strength member (CSM) back at the cable sheath. 4. Mark the buffer tube to have a 22" (56.0cm) opening. 5. Use accepted local practice to remove the buffer tube and clean the fiber. 4" (10.2 cm) Cable Sheath CABLE INSTALLATION The OPN-500 comes standard with three cable entry ports located at the bottom of the closures. Based on the application needs these ports will accept both NPT conduit fittings and compression fittings. 26" (66.0 cm) Caution: In order to avoid micro bends or fiber damage do not over-tighten the tie wraps around the fiber bundles. 1. For application that utilized the Compression Fitting Kit, determine the appropriate compression fitting for the application. 2. Install the compression fitting, reference the Compression Fitting Installation section of this document. 3. Secure the cable to the retention bracket using a tie wrap. (Figure 2) 4. Use accepted local practice to ground the tone wire to the grounding stud located at the bottom left side of the closure. A common ground will be established. 5. Route the buffer tube into the splice tray. Figure 2 4

CABLE INSTALLATION (CONTINUED) 6. Place one wrap of a foam spacer around the buffer tube. 7. Secure the buffer tube to the splice tray using a tie wrap. (Figure 3) PIGTAIL INSTALLATION Caution: In order to avoid micro bends or fiber damage do not over-tighten the tie wraps around the fiber bundles. 1. Use accepted local practice to clean the connector end face. 2. Plug the pigtail assembly into the adapter plate as specified by the local engineering practice. 3. Repeat steps 1-2 for each additional pigtail assembly to be installed. 4. Route the pigtail assemblies to the splice tray. Note: For best practice it is recommended that the pigtail assemblies be routed through protective transport tubing for mounting into the splice tray. 5. Place one wrap of a foam spacer around the tubing 6. Secure the tubing to the splice tray using a tie wrap. (Figure 4) Figure 3 COMPRESSION FITTING INSTALLATION Caution: In order to avoid micro bends or fiber damage do not over-tighten the tie wraps around the fiber bundles. Figure 4 5

COMPRESSION FITTING INSTALLATION (CONTINUED) 1. Ensure that the mounting hole is free from burrs and that the enclosure surface is smooth and free of debris. 2. Place the hex portion on the body (not the sealing nut) into the mounting hole. 3. Insert the cable through the fitting to the desired position Note: For best practice, it is recommended that when working with the 9-port compression fitting that the multi-port grommet be removed from the fitting body. Slit each end of the application appropriate ports and align the grommet around the cables. Once all required cables are seated in the grommet, insert both the cables and grommet back into the fitting body. 4. Tighten the sealing nut to hand-tight. 5. Using a wrench hold the body hex stationary while tightening the sealing nut with a second wrench. Tighten until the cable is help securely in place. 6. Check to ensure that the fitting body is still screwed tightly into the panel. DISASSEMBLE COMPRESSION FITTING CABLE REPLACEMENT 1. To disassemble for cable replacement, loosen the sealing nut. 2. Grip the disconnected cable and pull while turning the cable in the counter-clockwise direction. SPLICING Determine the location of the splice chip within the splice tray. 1. Remove the paper backing from the splice chip to expose the adhesive and place the chip at the desired location within the splice tray. 2. Prior to splicing, ensure that adequate slack for both the expressed fiber and the pigtail fiber is stored within the splice tray. Mark fibers for splicing. 3. Clean the individual fiber per accepted local practice using an approved fiber cleaner. 4. Follow accepted local practice for preparing and splicing express fibers and pigtail fibers. 5. Once all splicing is complete, route the exposed fibers inside the splice tray. (Figure 5) Note: The tab on the splice chip may be used to help organize loose tube bare fibers within the splice tray. 6. Replace the splice tray cover. Figure 5 6

ADAPTER PLATE INSTALLATION 1. Attach the adapter plate to the mounting bracket by pressing in the nylatch plungers. 2. Route the pigtail assembly around the splice tray. Use the routing rings located on the outer edge of the tray to help manage the cable. (Figure 6) DISTRIBUTION CABLE INSTALLATION PLUG AND PLAY Caution: In order to avoid micro bends or fiber damage do not over-tighten the tie wraps around the fiber bundles. 1. For application that utilized the Compression Fitting Kit, determine the appropriate compression fitting for the application. 2. Install the compression fitting, reference the Compression Fitting Installation section of this document. Figure 6 3. Secure the cable to the retention bracket using a tie wrap. (Figure 2) 4. Route the distribution cable with one turn around the splice tray. Use the routing rings located on the outer edge of the tray to help manage the cable. 5. Use accepted local practice to clean the connector end face. 6. Plug the distribution cable into the adapter plate as specified by the local engineering practice. 7. Repeat steps 3-6 for each additional distribution cable to be installed. (Figure 7) Note: A FASTConnect Mechanical Connector or FUSEConnect Splice-On Connector may be installed onto a non-connectorized distribution cable. Reference the installation instructions provided with the FASTConnect Mechanical Connector or FUSEConnect Splice-On Connector. The document will include the following: Fiber Preparation Fiber Termination Connector Assembly Figure 7 7

DISTRIBUTION CABLE INSTALLATION SPLICE ONLY For splice only applications, reference the Cable Preparation and Cable Installation sections of this documents for the distribution cable before continuing to the Splicing section of this document to complete the installation. 8