M1 BANK PETITION FOR FINAL SITE PLAN APPROVAL & CONDITIONAL USE PERMIT MANCHESTER ROAD DES PERES, MO 63131

Similar documents
DUNKIN DONUTS 206 EAST STATE STREET GENEVA, ILLINOIS


BERLIN MEADOWS. Faris Planning & Design SOUTH LANDSCAPE PLAN EXHIBIT D-1 PLANT KEY TYPICALS SEE PLANT LIST FOR SPECIFIC PLANT SPECIES

#26115 Mt. Diablo Blvd. and Dewing Ave Mt. Diablo Blvd. Lafayette, CA 94549

FOR SALE OR LEASE EBERHARDT & BARRY INC.

SUNSET BLVD. EL. 38'-0" EL. 56'-0" EL. 38'-0" ROOF TERRACE EL. 20'-0" PLAZA EL. 0'-0" PRIVATE TERRACE EL. 47'-0" POOL 3BR-UNIT A EL.

Fond du Lac, Wisconsin 79 East Division Street ELECTRICAL SITE PLAN E1.1 BUILDING #4 BUILDING #3

LEGAL DESCRIPTION REZONE PARCEL

Construction Staging Area 4 Avenue Road

MANDATORY MEASURES OUTDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130)

SUBDISTRICTS LEGAL DESCRIPTIONS DELETED FOR BREVITY. (60.1) WINDOW SIGN means a sign painted or affixed to a window.

GUIDELINES FOR ADVERTISING SIGNS

CODE ANALYSIS BUILDING AREA STORIES 2 BUILDING HEIGHT 25'


Assisted Living / Memory Care - South Forsyth

SPECIAL USE CRITERIA

SITE PLANS ASSISTED LIVING REDEVELOPMENT

East Allen County Schools Facilities History Calendar Years October 5, 2015

A-001 IRISH CULT URAL CENT ER HUDSON VALLEY COVER SHEET SHEET INDEX. Name. Abeel Street CONSULTANTS

PROJECT DATA PROJECT ADDRESS: OWNER:

THE BEST CHOICE FOR SPORTS FIELDS

Big Easy RV & Boat Storage A Green Energy Project Jana Lane Wildomar, California

The following provisions shall apply to the Broughton Street district:

Request for Statements of Qualification Gardnerville Station (Eagle Gas Station Redevelopment Project) 1395 Highway 395 N Gardnerville, NV

Appendix A ILLUSTRATIONS

400 SOUTH MAIN VICINITY MAP SITE PLAN ARCHITECTS ENGINEERS SURVEYORS PLANNERS FREDERICK WARD ASSOCIATES. frederickward.com 1"=2000'

REZ Zoning A-1 R-3C A-1 C-1 A-1 R-2AC R-3C A-1 R-5C R-4C O/SC O/SC O/SC R-2AC RTHC O/SC B-2C O-2C B-2C R-6C 400 A-1. OS/C to M-1C Ac.

CAPITAL FUND 9510 STREET & SIDEWALK IMPROVEMENTS FIVE-YEAR CAPITAL IMPROVEMENT PROGRAM FISCAL YEARS

Mission Bay South Signage Master Plan

FERRY TERMINAL IMPROVEMENTS PROJECT City of Sausalito. 1 st Joint Hearing April 1, 2015

Table Station Elements

RIVERCHASE RETAIL SIGNAGE CRITERIA

Center Street Partners, LLC

DESCRIPTION QUANTITY PRICE TOTAL

MOTOR VEHICLE ORIENTED BUSINESSES.

GENERAL NOTES AND REQUIREMENTS FOR PLUMBING AND ELECTRICAL WORK

ANDERSON DRIVE & LANDSCAPE 10'-0" PUE SETBACK BUILDING SETBACK SIGN 20'-0" ENTRY /EXIT 71'-3" CHILD CARE CENTER 4,700 S.F. EXIT EXIT PLAYGROUND

NEIGHBORING BUILDING 275' - 10" TRASH & RECYCLING VAN H/C L/T T 11' - 6 1/2" 32' - 0" 32' - 0" 53' - 6" 30' - 0" 30' - 0" 30' - 0" 30' - 0" 27' - 0"


THIS PAGE WAS LEFT BLANK INTENTIONALLY

15.14 SIGNS A. PURPOSE AND INTENT B. SEVERABILITY C. DEFINITIONS AND SPECIFICATIONS

2011 Asia Pacific Clean Energy Summit and Expo

Town of Medley Office of Capital Projects & Development Services 7777 NW 72 Avenue, Medley, Florida 33166

ELASTRIX LLC 95,591 + /- Square Feet on /- acres Pilot Mountain, North Carolina

TYPICAL DRIVEWAY CONSTRUCTION PER DOUGLAS COUNTY REGULATIONS AND POLICIES

The Courtyard Building - 2nd & 3rd Floor For Sale

UC San Diego Family Weekend Parking Guide

CAMPUS CONNECTOR MONDAY - THURSDAY. bold italicized times denote p.m. Monday - Thursday continued on next page. Effective August 29th, 2016

a. Type of Signs Freestanding signs shall be limited to ground and post and arm signs. [Amended Ordinance #06-14]

Please Refer to Attached Sample Form

CreekSide XVI & XVIII

Investment Portfolio. 48 Spiller Dr & 600 County Rd Westbrook, ME Property Highlights. Property Description. For Sale Industrial Buildings

METRO Magnolia Transit Center - Bid Tab

City of Casselberry Planning Division

11 October 12, 2011 Public Hearing APPLICANT:

PARKING STANDARDS GENERAL DESIGN PRINCIPLES AND INTENT

Water Supply & Fire Apparatus Access Requirements

VIRGINIA RAILWAY EXPRESS MANASSAS PARK STATION PARKING EXPANSION. Public Meeting June 20, 2017

Table of Contents. Division III: Sign Control ARTICLE 1 GENERAL SIGN REGULATIONS...1

ARTICLE 8 OFF-STREET PARKING AND PRIVATE DRIVEWAY STANDARDS

COMMISSION CIVIC DESIGN REVIEW - CONCEPTUAL DESIGN AUGUST, 2017

City of Houston Fondren Road Paving and Drainage

PARKING REGULATIONS MAP

Solid Waste Service Company Review and Collection Space Standards

COPPER RUN PRELIMINARY PLANS FOR LITTLE CREEK HUNDRED, KENT COUNTY DELAWARE COPPER RUN GENERAL NOTES. DATA COLUMN PyA FgA SITE.

AVAILABLE Island Ford Road, Madisonville, KY. Industrial Building

WASHINGTON UNIVERSITY IN ST. LOUIS DEPARTMENT OF FACILITIES PLANNING & MANAGEMENT ACCESS CONTROL & ELECTRONIC SECURITY OFFICE

10 May 14, 2014 Public Hearing

Letter of Determination

Expo Light Rail Line Project Status Update Meeting Holman United Methodist Church January 27, 2011

DRIVER OUTPUT F Fixed DM 0-10v Dimming 1 COLOR TEMP 51K 5100

QCF IP65. LED Gas Canopy Fixture SPECIFICATIONS CERTIFICATION ORDERING INFORMATION EXAMPLE QCF-UL-60C-F-51K-GCO CERTIFIED

Knife & Rail. LED Indirect/Direct Pendants. Contains Variable Intensity Technology

LED LINEAR QUICK SUMMARY CO W SI MODEL CORTANA

CITY OF GRAND ISLAND UTILITIES DEPARTMENT ELECTRIC RATE SCHEDULE Effective October 1, Ordinance No. 9133

Cedar Blue Property Owners Association Board Meeting Minutes November 17, 2018

Wilson Pacific Elementary and Middle School. Departures Committee 28 May 2014

FUTURE 31 PARKING SPACES CONCRETE DRIVE / FIRE LANE MAIN ENTRY LANDSCAPING OFFICE LANDSCAPING W/H R R MW MW MW MW MW MW MW R R R D/W RANGE

ORDINANCE NO. 176,558 RESEDA CENTRAL BUSINESS DISTRICT COMMUNITY DESIGN OVERLY PERMANENT [Q] CONDITIONS

New Construction, Mixed Use Opportunity 6351 Crawfordsville Rd, Indianapo-

SITE PLAN SP1 ROCKWALL MOB CLINIC LOT 2, BLOCK B NORTH LAKESHORE VALLEY SITE DATA INFORMATION ROCKWALL MOB CLINIC

Cedar View Subdivision No. 2 Hillcrest Dr. Montrose, Colorado 81401

STAFF REPORT. To: Planning Commission Meeting date: April 12, 2017 Item: UN Prepared by: Robert Eastman

Appendix C. 5% Design Plan and Profile Drawings/ Additional Design Information. South Oak Cliff Corridor Blue Line Extension

STANDARD DRAWING INDEX

TOWN OF LAGRANGE FY RATE SCHEDULE

Outdoor Lighting Stakeholder Meeting #2

Street Lighting Policy. Revision

PROPOSED DEVELOPMENT 18 OTEHA VALLEY ROAD EXTENSION, ALBANY

Report Date: May 18, 2012 Contact: Al Zacharias Contact No.: RTS No.: 9587 VanRIMS No.: Meeting Date: June 12, 2012

Capital Improvement Projects Status Report December 2014 (Actuals through October) Percent Design Complete. Design Finish. Construction Finish

FOR REFERENCE ONLY LEGEND: GENERAL NOTES: UNDERGROUND GARAGE LEVEL FLOOR PLAN DR-10-0 SCALE : 1" = 30'-0"

UBC Watermain as shown on Sheet 202 : Sub total 97,050

ARCHITECTURAL COMMITTEE. Signage Regulations for Retail Sites in Arrowhead Park and the Maumee C-M District

Logistics Reststop Supply Friday Distribution Sheets with Truck Loading

TRAFFIC PARKING ANALYSIS

LOCAL CLIMATOLOGICAL DATA Monthly Summary April 2017

Neighborhood Traffic Calming Options

Ohio Department of Transportation Official Bid Tabulation Jolene M. Molitoris, Director

Appendix G Aquilla Lake Pool Rise Recreational Resources

Transcription:

M1 BANK PETITION FOR FINAL SITE PLAN APPROVAL & CONDITIONAL USE PERMIT 11679 MANCHESTER ROAD DES PERES, MO 63131 N. BALLAS RD BOPP RD PRELIMINARY - NOT FOR CONSTRUCTION SHEET INDEX - SITEPLAN & CUP G-0 COVER SHEET C1 OF 2 CIVIL COVER SHEET C2 OF 2 MASTER DEVELOPMENT PLAN L1.0 LANDSCAPE MITIGATION PLAN L1.1 LANDSCAPE DEVELOPMENT PLAN A-1 ARCHITECTURAL SITE PLAN A-2 EXISTING PHOTOS A-3 BUILDING ELEVATIONS A-4 BUILDING ELEVATIONS A-5 CANOPY ELEVATIONS A-6 EXTERIOR RENDERING A-7 TRASH ENCLOSURE A-8 SIGNAGE E-1 SITE LIGHTING PHOTOMETRICS - NW QUADRANT E-2 SITE LIGHTING PHOTOMETRICS - NE QUADRANT E-3 SITE LIGHTING PHOTOMETRICS - SE QUADRANT E-4 SITE LIGHTING PHOTOMETRICS - SW QUADRANT E-5 SITE LIGHTING PHOTOMETRICS - SCHEDULES APPENDIX A DRAFT TRAFFIC STUDY REPORT EXPLANATION OF IMPROVEMENTS THIS PROJECT CONSISTS OF RENOVATION OF AN EXISTING BRICK BUILDING. THE BUILDING WAS FORMERLY A MERCANTILE USE AND WILL BE RENOVATED TO SERVE AS A BANKING FACILITY (BUSINESS OCCUPANCY). A FREESTANDING DRIVE-THRU CANOPY WILL BE ADDED IN THE EXISTING PAVED AREA TO THE WEST OF THE BUILDING. THE MAJORITY OF THE EXTERIOR IS INTENDED TO REMAIN. THE BRICK WILL BE STAINED, EXISTING EIFS PAINTED AND SOME PORTIONS OF EIFS WILL BE REPLACED WITH STAINED BRICK TO MATCH. THE FRONT ENTRY TOWER WILL BE REWORKED TO REMOVE THE EXISTING VESTIBULE DOORS. PORTIONS OF THE BRICK ON THE EXISTING FRONT COLUMNS WILL BE REMOVED AND REPLACED WITH STONE-LIKE MATERIAL TO MATCH THE PAINTED EXISTING EIFS. THIS COULD BE EIFS, THIN STONE PANELS OR REAL STONE. EXISTING WINDOW OPENINGS WILL BE ENLARGED AND REPLACED WITH NEW WINDOWS. SOME NEW OPENINGS WILL BE ADDED. THE FREESTANDING DRIVE-THRU WILL BE OF SIMILAR DESIGN AND MATERIAL TO THE REWORKED FRONT ENTRY TOWER. PARKING ALONG THE SOUTH AND EAST SIDES OF THE BUILDING WILL REMAIN. THE WEST SIDE PAVING WILL BE MODIFIED TO INCORPORATE THE DRIVE-THRU AREA. THE BANK WILL OFFER A FULL RANGE OF PERSONAL AND BUSINESS PRODUCTS THAT WILL DELIVER PROGRESSIVE BANKING SOLUTIONS BASED ON AN INDIVIDUAL'S NEEDS AND FINANCIAL GOALS, AS WELL AS INCLUDING CREDIT AND CASH MANAGEMENT SERVICES TO THEIR BUSINESS RELATIONSHIPS. OTHER SERVICES WILL INCLUDE DIRECT DEPOSIT, ONLINE BANKING, BILL PAY, E-STATEMENTS, MOBILE ACCESS, AND ANYTIME ATM. THE BANK WILL OFFER A FULL-SERVICE FACILITY WITH A WALK-IN LOBBY AND DRIVE THRU, AS WELL AS A 24-HOUR ACCESSIBLE ATM. THE HOURS OF OPERATION WILL BE: LOBBY DRIVE-THRU MONDAY-FRIDAY 9am - 5pm 8:30am - 5pm SATURDAY 9am - noon 9am - noon SUNDAY Closed Closed MANCHESTER RD LINDEMANN RD 2009 INTERNATIONAL BUILDING CODE ZONING CLASSIFICATION C-1 COMMERCIAL DISTRICT LOCKETT RD DESCRIPTION OF WORK RENOVATION OF EXISTING 1 STORY BRICK BUILDING WITH NEW DRIVE-THRU CANOPY STRUCTURE USE GROUP: FIRE SUPPRESSION SYSTEM: B (BUSINESS) UNPROTECTED CONSTRUCTION TYPE: VB (IBC 602.5) ALLOWABLE AREA: 9,000 SF ALLOWABLE, 2 STORIES (40' TALL) (IBC T503) AREA OF WORK: LOCATION MAP NOT TO SCALE CODE INFORMATION - DES PERES, MO BUILDING = 5,918 SF EXISTING, 118 SF VESTIBULE TO BE REMOVED NEW BUILDING TOTAL = 5,800 GSF CANOPY = 1,100 GSF N. GEYER RD COVER SHEET 0" 1/2" 1" G-0

UTILITY INFORMATION DES PERES FIRE PROTECTION DISTRICT 1000 NORTH BALLAS ROAD CITY OF DES PERES, MISSOURI 63131 (314) 835-6200 METROPOLITAN ST. LOUIS SEWER DISTRICT 2350 MARKET STREET ST. LOUIS, MISSOURI 63103 (314) 768-6272 CONTACT: ENGINEERING MISSOURI-AMERICAN WATER COMPANY 727 CRAIG ROAD CREVE COEUR, MISSOURI 63141 (314) 991-3404 CONTACT: DAVE MOORE AMEREN UE PO BOX 66149 ST. LOUIS, MISSOURI 63166-6149 (314) 554-3761 CONTACT: DAVE MUNTINE SPIRE (GAS COMPANY) 720 OLIVE STREET ST. LOUIS, MISSOURI 63101 (314) 342-0782 CONTACT: DAN RYAN AT & T 909 CHESTNUT STREET ST. LOUIS, MISSOURI 63101 (314) 235-9979 CONTACT: R.O.W. DEPARTMENT

4 LOT 18 6 COUNTRYSIDE IN DES PERES PB. 339 PG. 6 LOT 17 PART OF LOT A OF WEINHARDT SUBD. PB.360 PG.211 63346 SQUARE FEET 1.454 ACRES 8 6 7 GREASE SAN GAS ELECTRIC WATER LOT 16 LOT 15

NEW TRASH ENCLOSURE SEE SHEET A-7 23' - 6" PRELIMINARY - NOT FOR CONSTRUCTION 50' - 0" 35 40' - 0" FRONT SETBACK PER ZONING LOCKETT ROAD RIGHT-OF-WAY REAR SETBACK DRIVE-THRU CANOPY STRUCTURE 42' - 5" 1 ARCHITECTURAL SITE PLAN A-1 1" = 30'-0" 25' - 11" 15' - 0" EXISTING BUILDING 1 13 21 EXISTING SIGN LOCATION TO BE REUSED 14 60' - 0" MANCHESTER RIGHT-OF-WAY FRONT SETBACK FROM MANCHESTER 22 ARCHITECTURAL SITE PLAN 0" 1/2" 1" A-1

EXISTING BRICK TO BE STAINED. PORTIONS AT ENTRY COLUMNS REMOVED AND REPLACED WITH EIFS OR STONE ALL AWNINGS TO BE REMOVED, WINDOWS TO BE ENLARGED EXISTING EIFS PARAPET AND WALLS TO REMAIN, TO BE PAINTED "STONE" COLOR NEW WINDOWS THIS FACADE, EIFS REPLACED WITH STAINED BRICK PORTION OF DRIVE REMOVED AND REPLACED WITH LANDSCAPING AND PATIO AREA LOADING DOCK TO BE REMOVED PRELIMINARY - NOT FOR CONSTRUCTION EXISTING FRONT / SOUTH ELEVATION EXISTING EAST ELEVATION EXISTING NORTH ELEVATION DUMPSTER ENCLOSURE TO BE REMOVED PAVING REWORKED FOR DRIVE-THRU CANOPY LOADING DOCK TO BE REMOVED EXISTING PHOTOS EXISTING NORTH ELEVATION EXISTING WEST ELEVATION EXISTING DUMPSTER ENCLOSURE - TO BE REMOVED 0" 1/2" 1" A-2

BACKLIT BUILDING MOUNTED LETTERS 14' - 2" PIN MOUNTED LETTERS/NUMBERS 2' - 0" EXISTING EIFS PARAPET PAINTED TO MATCH NEW COLUMN WRAPS AT ENTRY TOWER NEW BRICK DUMPSTER ENCLOSURE BEYOND. SEE SHEET A-7 28' - 5 1/4" NEW ENLARGED WINDOWS WITH DECORATIVE SCREEN, TYP. PRELIMINARY - NOT FOR CONSTRUCTION EXISTING TRANFORMER TO REMAIN 1 SCHEMATIC SOUTH ELEVATION A-3 1/8" = 1'-0" EXISTING EIFS WALL PANELS TO BE PAINTED PORTION OF EIFS TO BE REMOVED AND REPLACED WITH STAINED BRICK EXISTING VESTIBULE ENCLOSURE REMOVED. ENTRY REWORKED AND PARTIALLY RECLAD NEW DOOR OPENING 19' - 8 3/4" NEW COLUMN WRAPS OF EIFS OR "STONE" EXISTING BRICK - STAINED TYP. BUILDING ELEVATIONS 0" 1/2" 1" 2 SCHEMATIC WEST ELEVATION A-3 1/8" = 1'-0" A-3

EXISTING EIFS PARAPET AND WALL PANELS TO BE PAINTED EXISTING OVERHEAD DOOR TO BE REMOVED AND REPLACED BY ONE WITH MORE GLAZING PRELIMINARY - NOT FOR CONSTRUCTION 2 SCHEMATIC NORTH ELEVATION A-4 1/8" = 1'-0" EXISTING VESTIBULE ENCLOSURE REMOVED. ENTRY REWORKED AND PARTIALLY RECLAD PORTION OF EIFS REMOVED AND REPLACED WITH STAINED BRICK NEW WINDOW OPENINGS BUILDING ELEVATIONS 0" 1/2" 1" 1 SCHEMATIC EAST ELEVATION A-4 1/8" = 1'-0" A-4

PRELIMINARY - NOT FOR CONSTRUCTION CANOPY SKYLIGHT, POSSIBLY TO INCLUDE PV PANELS DRIVE-THRU CANOPY COLUMNS AND ROOF CLAD WITH EIFS / "STONE" PANELS TO MATCH EXISTING BUILDING 3' - 10 5/8" CANOPY ELEVATIONS 20' - 0 3/8" 23' - 11" 0" 1/2" 1" 2 A-5 SCHEMATIC CANOPY WEST ELEVATION (EAST SIM) 1/8" = 1'-0" 1 A-5 SCHEMATIC CANOPY SOUTH ELEVATION (NORTH SIM) 1/8" = 1'-0" A-5

PRELIMINARY - NOT FOR CONSTRUCTION EXTERIOR RENDERING 0" 1/2" 1" A-6

10' - 0" SIGHT PROOF GATE STONE CAP BRICK TO MATCH THE BUILDING 6" DIA STEEL PIPE BOLLARD FILL W/ CONC 4' - 0" EXPANSION JOINT 8' - 0" 2' - 6" 12" DIA CONC PIER TO 36" BELOW FIN GRADE. PIPE TO 30" BELOW GRADE BRICK WATER TABLE COURSE TO MATCH THE BUILDING PRELIMINARY - NOT FOR CONSTRUCTION 10' - 0" 8' - 0" 8' - 0" 5 DETAIL @ BOLLARD (ARB) A-7 1/4" = 1'-0" 13' - 10" 4 TRASH ENCLOSURE SECTION A-7 1/4" = 1'-0" 6"X6" GATE POST FILLED W/ CONC. MIN 30" DELOW GRADE, TYP. EJ CJ EJ 6" PCC W/ REINF. 6X6XW1.4XW1.4 10' - 0" CJ EJ 12' - 8" TRASH ENCLOSURE 4 Sim A-7 3 TRASH ENCLOSURE SIDE ELEVATION A-7 1/4" = 1'-0" SIGHT PROOF GATE 2 TRASH ENCLOSURE FRONT ELEVATION A-7 1/4" = 1'-0" SIGHT PROOF GATE 1 TRASH ENCLOSURE PLAN A-7 1/4" = 1'-0" 0" 1/2" 1" A-7

9 3/4" 3 SF ILLUMINATED LETTERING PRELIMINARY - NOT FOR CONSTRUCTION 5' - 6" 1' - 0" 3" 1' - 0" 3' - 0" 3" 3" 1" M1 BANK 4' - 6 1/2" 6' - 6" 13.5 SF COMMANDER BOARD SIGN 4' - 9 1/8" 9 1/8" 3' - 0" 1' - 0" 4' - 6 1/2" 6' - 6" SIGNAGE NEW SIGN USES EXISTING SIGN STRUCTURE. EXISTING RUSSELL STOVER SIGN REMOVE CAP AND ADD STONE BANDING, CAP AND NEW FACE FOR LETTERING. REPLACE BRICK VENEER WITH STONE VENEER TO MATCH RENOVATED BUILDING EXTERIOR. ILLUMINATED SIGNAGE PANELS FOR RUSSELL STOVER ARE REPLACED WITH COMMANDER BOARDS. ELEVATION IS THE SAME ON BOTH FACES. 1 MONUMENT SIGNAGE ELEVATION A-8 3/4" = 1'-0" 0" 1/2" 1" A-8

NW QUADRANT NE QUADRANT 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.1 0.1 0.1 0.1 0.0 0.1 0.1 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.0 0.0 0.1 0.1 0.2 0.2 0.1 0.0 0.0 0.0 0.0 2.7 3.2 3.3 3.0 2.4 2.0 1.9 2.1 1.0 1.0 1.2 1.9 2.7 3.4 3.6 3.6 3.2 2.8 2.5 2.4 0.7 0.8 0.9 1.1 1.2 1.3 1.3 2.1 3.1 4.3 5.0 5.3 5.0 4.7 3.8 3.1 0.5 0.6 0.8 1.0 1.0 1.1 1.3 1.6 1.9 1.6 2.6 4.3 6.2 7.1 8.0 7.1 7.5 5.4 4.1 0.7 0.9 1.2 1.3 1.3 1.6 2.0 2.6 2.4 3.1 5.5 4.7 1.1 1.3 1.5 1.5 1.7 2.2 3.0 3.7 4.5 1.4 1.5 1.6 1.7 1.7 2.2 2.9 3.7 2.2 1.8 1.9 1.7 1.7 1.8 1.8 2.4 2.6 3.2 3.0 0.9 SITE LIGHTING PHOTOMETRICS NW QUADRANT 2.5 2.6 2.2 1.9 2.6 3.3 6.0 4.5 4.2 2.7 NE QUADRANT 0.8 SW QUADRANT 0.1 0.0 0.0 0.1 0.0 0.0 0.1 0.2 1 SITE LIGHTING PHOTOMETRICS - NW QUADRANT E-1 1" = 20'-0" SE QUADRANT 3.1 2.6 2.4 6.6 12.3 21 20 20 11.4 3.5 0.7 18 19 21 22 23 24 21 18 19 19 20 20 22 25 25 22 CANOPY STRUCTURE 2.9 2.8 4.1 3.4 0.7 18 21 21 20 19 19 20 24 24 22 16 17 21 23 22 20 18 18 20 22 22 20 10 2.5 7.2 22 25 25 21 19 18 19 19 18 2.2 0.7 SW QUADRANT SE QUADRANT 0" 1/2" 1" E-1

NW QUADRANT NE QUADRANT 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.1 0.0 0.1 0.1 0.2 0.2 0.0 0.0 0.1 0.1 0.0 0.0 2.7 3.2 3.3 3.0 2.4 2.0 1.9 2.1 2.6 3.2 1.0 1.0 1.2 1.9 2.7 3.4 3.6 3.6 3.2 2.8 2.5 2.4 2.8 3.2 3.4 0.9 1.1 1.2 1.3 1.3 2.1 3.1 4.3 5.0 5.3 5.0 4.7 3.8 3.1 2.8 2.7 2.7 1.1 1.3 1.6 1.9 1.6 2.6 4.3 6.2 7.1 8.0 7.1 7.5 5.4 4.1 2.8 2.2 2.0 1.8 1.4 1.3 1.6 2.0 2.6 2.4 3.1 5.5 4.7 2.7 1.9 1.6 1.5 1.2 0.8 1.5 1.7 2.2 3.0 3.7 4.5 2.4 1.7 1.5 1.5 1.3 0.8 1.7 1.7 2.2 2.9 3.7 2.2 1.8 1.4 1.4 1.5 1.5 1.0 1.8 1.8 2.4 2.6 3.2 3.0 0.9 1.2 1.2 1.4 1.6 1.8 1.7 21 35 0.1 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.2 0.0 0.0 0.3 0.1 0.0 0.3 0.1 0.0 0.1 0.0 0.1 0.1 0.0 SITE LIGHTING PHOTOMETRICS 2.6 MATCHLINE 3.3 6.0 - NW 4.5 QUADRANT 4.2 2.7 0.8 0.9 1.1 1.4 1.7 2.2 2.4 0.2 0.1 0.0 NE QUADRANT SW QUADRANT 6.6 12.3 21 20 20 11.4 3.5 0.7 0.8 1.0 1.4 1.9 2.6 3.2 0.5 18 19 21 22 23 24 21 18 19 19 20 20 22 25 25 22 CANOPY STRUCTURE 21 21 20 19 19 20 24 24 22 16 21 23 22 20 18 18 20 22 22 20 10 SW QUADRANT SE QUADRANT 3.4 0.7 0.7 0.9 1.3 1.9 2.5 3.2 1.5 2 SITE LIGHTING PHOTOMETRICS - NE QUADRANT E-2 1" = 20'-0" 0.2 0.1 0.0 0.2 0.1 0.1 SE QUADRANT 0" 1/2" 1" E-2

1.7 2.2 2.9 3.7 2.2 1.8 1.4 1.4 1.5 1.5 1.0 1.8 2.4 2.6 3.2 3.0 0.9 1.2 1.2 1.4 1.6 1.8 1.7 3.3 MATCHLINE 6.0 4.5- NW QUADRANT 4.2 2.7 0.8 0.9 1.1 1.4 1.7 2.2 2.4 10 SW QUADRANT 12.3 21 20 20 11.4 3.5 0.7 0.8 1.0 1.4 1.9 2.6 3.2 0.5 CANOPY STRUCTURE 16 18 19 21 22 23 24 21 19 19 20 20 22 25 25 22 21 20 19 19 20 24 24 22 16 22 20 18 18 20 22 22 20 25 21 19 18 19 19 18 24 22 20 19 17 22 20 18 NW QUADRANT NE QUADRANT 3.4 0.7 0.7 0.9 1.3 1.9 2.5 3.2 1.5 2.2 0.7 0.7 0.9 1.2 1.7 2.2 2.6 2.3 3.4 1.9 0.7 0.8 1.0 1.2 1.5 1.8 1.9 1.8 9 11 12 13 14 14 13 13 12 10 9 14 0.1 0.0 0.1 0.1 0.0 0.2 0.1 0.0 0.2 0.1 0.0 0.2 0.1 0.1 0.1 0.0 0.0 0.1 0.0 0.0 NE QUADRANT SE QUADRANT 10 12 13 15 15 15 15 14 13 12 10 10 12 13 15 15 15 15 14 13 12 10 4.1 2.9 1.7 1.7 3.3 2.1 6.19 11 12 14 14 14 14 14 12 11 9 3.9 SF 11 12 13 13 13 12 11 SF 1.5 1.5 1.0 1.1 1.2 1.4 1.5 1.5 1.3 9 SF SF 10 10 10 10 10 9 2.0 2.2 2.1 1.9 1.8 1.5 1.2 1.0 4.4 4.0 0.9 1.1 1.0 1.1 1.2 1.2 1.3 1.3 1.3 1.1 0.5 1.9 2.5 2.7 2.3 1.9 1.5 1.1 1.0 1.4 1.3 1.0 1.0 1.2 1.3 1.4 1.4 1.4 1.3 1.1 0.9 0.7 2.8 3.2 2.8 2.2 1.6 1.1 1.0 1.1 1.2 1.2 1.3 1.5 1.7 1.7 1.6 1.4 1.2 1.0 EXISTING SIGN LOCATION 3.1 2.3 1.6 1.2 1.1 1.1 1.2 1.3 TO BE 1.5 REUSED1.9 2.3 2.3 2.0 1.6 1.2 0.9 2.6 2.0 1.4 1.1 1.0 1.0 1.1 1.3 1.7 2.4 3.0 3.0 1.7 1.2 0.8 1 13 1.5 1.2 0.9 0.7 0.7 0.8 1.0 1.6 2.3 3.0 3.0 1.6 0.9 0.5 MANCHESTER RIGHT-OF-WAY 0.0 0.0 0.0 0.1 0.1 0.2 0.3 0.3 0.3 0.2 0.1 0.1 0.1 0.1 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 SW QUADRANT SE QUADRANT 3 SITE LIGHTING PHOTOMETRICS - SE QUADRANT E-3 1" = 20'-0" 22 0.1 0.0 0.0 0.1 0.0 0.0 0.1 0.0 0.0 SITE LIGHTING PHOTOMETRICS 0" 1/2" 1" E-3

0.0 1.1 1.3 1.5 1.5 1.7 2.2 3.0 3.7 1.4 1.5 1.6 1.7 1.7 2.2 2.9 3.7 NW QUADRANT NE QUADRANT 0.0 1.8 1.9 1.7 1.7 1.8 1.8 2.4 2.6 3.2 3.0 NW QUADRANT 2.5 2.6 2.2 1.9 2.6 3.3 6.0 4.5 4.2 2.7 NE QUADRANT SW QUADRANT 0.1 3.1 2.6 2.4 6.6 12.3 21 20 20 11.4 3.5 10 18 19 21 22 23 24 21 SE QUADRANT 0.0 0.0 0.1 0.0 0.0 0.1 0.2 0.0 0.1 0.1 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.1 0.1 0.1 0.0 0.1 0.0 LOCKETT 0.0 0.0 ROAD 0.0 RIGHT-OF-WAY 0.0 0.0 18 19 19 20 20 22 25 25 22 CANOPY STRUCTURE 2.9 2.8 4.1 3.4 18 21 21 20 19 19 20 24 24 22 16 17 21 23 22 20 18 18 20 22 22 20 2.5 7.2 22 25 25 21 19 18 19 19 18 2.2 20 24 24 22 20 19 17 21 22 20 18 1.6 4.4 14.4 3.4 1.9 16 10 12 13 15 15 15 15 14 13 12 10 1.8 2.8 4.1 2.9 1.7 1.7 3.3 2.1 6.19 11 12 14 14 14 14 14 12 11 9 3.9 SF 11 12 13 13 13 12 11 SF 1.5 9 SF SF 10 10 10 10 10 9 1.2 2.0 2.2 2.1 1.9 1.8 1.5 1.2 1.0 4.4 4.0 0.9 1.1 0.7 1.9 2.5 2.7 2.3 1.9 1.5 1.1 1.0 1.4 1.3 1.0 1.0 0.7 2.8 3.2 2.8 2.2 1.6 1.1 1.0 1.1 1.2 1.2 1.3 EXISTING SIGN LOCATION 3.1 2.3 1.6 1.2 1.1 1.1 1.2 1.3 TO BE 1.5 REUSED 1 9 11 12 13 14 14 13 13 12 10 9 10 12 13 15 15 15 15 14 13 12 10 2.6 2.0 1.4 1.1 1.0 1.0 1.1 1.3 1.7 1.5 1.2 0.9 0.7 0.7 0.8 1.0 1.6 0.0 0.1 0.1 0.2 0.3 0.3 0.3 0.2 0.1 0.1 0.1 SITE LIGHTING PHOTOMETRICS 4 SITE LIGHTING PHOTOMETRICS - SW QUADRANT E-4 1" = 20'-0" 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 SW QUADRANT SE QUADRANT 0" 1/2" 1" E-4

Luminaire Schedule Symbol Qty Label Arrangement Manufacturer Description Lum. Watts Total Watts LLF BUG Rating 1 SA SINGLE PHILIPS GARDCO ECF-S-32L-1.2A-NW-G2-AR-3-UNV-BK-HIS-ECF-RAM-G2-BK 122 122 0.850 B1-U0-G2 4 SB SINGLE PHILIPS GARDCO ECF-S-32L-1.2A-NW-G2-AR-4-UNV-BK-HIS-ECF-RAM-G2-BK 122 488 0.850 B1-U0-G3 12 SC SINGLE LITON LIGHTING CH648UE-10/CR6L36SW-T40 49 588 0.850 B2-U1-G1 10 SE SINGLE Liton Lighting Inc WLP31B-25W-UN-DUN-SH UPLIGHT 30 300 0.850 N.A. 1 SA - CHANGE TWIN TO SINGLE SINGLE PHILIPS GARDCO ECF-S-32L-1.2A-NW-G2-AR-3-UNV-BK-HIS-ECF-RAM-G2-BK 122 122 0.850 B1-U0-G2 1 SA - NEW POLE ASSEMBLY SINGLE PHILIPS GARDCO ECF-S-32L-1.2A-NW-G2-AR-3-UNV-BK-HIS-ECF-RAM-G2-BK/SSS4-20-4-11-D1-BLP 122 122 0.850 B1-U0-G2 8 SF SINGLE PHILIPS-HADCO LIGHTING I35NNFC 25 200 1.000 B2-U0-G0 5 SG SINGLE PHILIPS GARDCO 111L-16L-550-NW-G2-4-UNV-BK 29 145 0.850 B1-U0-G1 Calculation Summary Label CalcType Units Avg Max Min Avg/Min Max/Min FRONT ENTRY Illuminance Fc 12.16 15 9 1.35 1.67 PARKING AND DRIVES Illuminance Fc 2.17 14.4 0.5 4.34 28.80 SPILL Illuminance Fc 0.04 0.3 0.0 N.A. N.A. Under Canopy Illuminance Fc 20.40 25 10 2.04 2.50 Notes: Pole Mounting Height 20'0" plus 2.5' concrete pedestal Under Canopy Downlight Mounting Height 15.4' or 14.0' at the front of Under Canopy Uplight Mounting Height 16.4' Exterior Wall Bracket Mounting Height 9.5' to bottom Calculation Points: 10' x 10' Spacing TRANSLUCENT ROOF 50% TRANSMITTANCE MAINTAINED LIGHT LEVELS ISOFC CURVES ARE FOR.5 FC, MAINTAINED SITE LIGHTING PHOTOMETRICS 5 SITE LIGHTING PHOTOMETRICS - SCHEDULES E-5 1" = 20'-0" 0" 1/2" 1" E-5