ISO 9001 Certified Fitting and Valve Manufacturer

Similar documents
INSTRUMENTATION. Tube Fittings. Catalog Number 01-5 November,

THE PREMIUM QUALITY. Hydraulic Swaging Unit for Pre-Swaging Over 1. Catalog Number 01-5 March, 2009 HYDRAULICSWAGINGUNIT.

THE PREMIUM QUALITY. Catalog Number 01-5 November,

Table Of Contents. Assembly Instructions. Identification of Sync-Lok Tube Fittings. Reducing Port Connector 36. Male Elbow 11

Gaugeable Tube Fittings and Adapter Fittings

Product warranty. Quality Policy. The Goal

TUBE FITTINGS INSTRUMENTATION.

TUBE FITTINGS INSTRUMENTATION.

An Installer s Pocket Guide for Swagelok Tube Fittings

Gaugeable Tube Fittings and Adapter Fittings

Gaugeable Tube Fittings and Adapter Fittings

DOUBLE FERRULE FITTINGS FLUID CONTROLS PRIVATE LIMITED

Fittings, Materials and Tubing Guide. Instrumentation Products

Gaugeable Tube Fittings and Adapter Fittings


Swagelok Medium-Pressure, Gaugeable Tube Fit tings and Adapte r Fit tings

Pipe Fittings 1/16 to 1 in. sizes 316 stainless steel, brass, and carbon steel NPT, ISO/BSP, and SAE threads

ins LET-LOK (IMPERIAL) TUBE FITTINGS Page About Twin Ferrule Compression Fittings 2 Installation Instructions 3

STAUFF. Klemmringverschraubungen Twin Ferrule Compression Fittings. Local solutions for individual customers worldwide

Forged High Pressure Pipe Fittings

Gaugeable Alloy 400 Mechanically Attached Pipe and Tube Fittings

Copper-Nickel Alloy for Seawater Piping Systems (CuNi 90/10)

3-PIECE TUBE ASSEMBLY

COMPRESSION TUBE FITTINGS 1/16 THROUGH 2 -INCH, 2 MM THROUGH 50 MM-METRIC

Instrument Pipe & ISO Conversion Fittings. Catalog 4260 Revised, February 1999

Instrument Pipe Fittings Instrument Pipe Fittings Introduction Parker Instrumentation Pipe Fittings are designed as leakfree connections for process,

Instrumentation Pipe & Weld Fittings. No.03-9 August 2017

DK-LOK Hydraulic Pipe Fittings

VCR Metal Gasket Face Seal Fittings

Yl)HAl STrrl (INDIA) Forged High Pressure Pipe Fittings. All ISO 9001:2003/ ISO 14001:2004 / 8S Ol!SAS 18001:2007 / PED Al'PROl'ED 97/23/EC

Pipe Fittings. 1/16 to 1 in. sizes. 316 stainless steel, brass, and carbon steel. NPT, ISO/BSP, and SAE threads.

COMPRESSION TUBE FITTINGS CONNECTORS

VCR. Metal Gasket Face Seal Fittings. 1/16 to 1 in. and 6 to 18 mm sizes. High-purity stainless steels

Certificate of Type Approval (RQS)

VC & VPC Series Check Valves

Introduction Parker are designed for uni-directional flow control of fluids and gases in industries such as chemical processing, oil and gas productio

Copper & Copper Nickel. Pipes Fittings Flanges.

Crosby Series 800 and 900 OMNI-TRIM Pressure Relief Valves. Flow Control

Thread and Connector Identification

Check Valves (C Series) Catalog 4130-C Revised, July 2004

SCREWED BONNET NEEDLE VALVES

Section 7. Socket Weld and Threaded Fittings. Socket Weld and Threaded Fittings 7-1

Multi-Circuit Rotary Block

Clean Fittings. No.06-2 August 2015

Pipe Fittings. HP Series

UNITS 1-3 EAGLE WORKS 2 SPRINGCROFT ROAD TYSELEY BIRMINGHAM B11 3EL

V33, VP33, VA33, VDA33, VH36 and VL36 Series for VCH36 Series for CNG/NGV applications Pressures up to 3,000 psig (206 bar) and 6,000 psig (413 bar)

Tool Reference Guide. Swagelok Minnesota North Dakota Appleton offers a complete line of tools and equipment to rent or purchase.

Tube Fitting Stainless SUS316 Compression Fitting Series

COMPRESSION TUBE FITTINGS 1/16 THROUGH 2 2 MM THROUGH 50 MM

Copper-Nickel Seawater Piping Systems Offshore product range: Pipes, fittings and flanges of OSNA 10

Engineering Data. Assembly Length. How to Determine Correct Assembly Length

Hi-Duty Flareless Tube Fittings

Compression Fittings. Brass Compression Fittings. Stainless Steel Compression Fittings. PL Nickel-Plated Brass Spigot Fittings

V33, VP33, VA33, VDA33, VH36 and VL36 Series for VCH36 Series for CNG/NGV applications Pressures up to 3,000 psig (206 bar) and 6,000 psig (413 bar)

INSTRUMENTATION ULTRA HIGH PURITY FITTINGS & VALVES

* Contact your sales representative for compliance to NACE MR or later requirements.

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL PIPE WORK. This work covers part of outcome 2 of the Edexcel standard module:

Compression Style Transportation

SPEED CONTROLLERS WITH QUICK FITTINGS


Exhaust Throttle (Needle) Valve ET

Full Traceability. Material Specification. Raw Material Code. Heat Treatment

Connector Series. Multiple Push-In Fitting Type. Desorption of Several Tubes at One Time. Combinable Connectors by Connector Band.

SEAMLESS & WELDED PIPE

Brass Compression Fitting Range

Solution Partner. Leak - Proof Flow & Control. Check & Relief Valves. W e. s u p p o r t. t h e. i n n o v a t i o n s. o f.

Gyrolok Flareless Tube Fittings Tubing Data Charts

Pneufit Inch Series Push-In Tube Fittings 1/8" to 1/2" Tube Sizes UNF to 1/2" NPT Thread Options

Metal Gasket Face Seal Fittings

Medium- and High-Pressure Fittings, Tubing, Valves, and Accessories

Instrument Thread Fittings High Technology Valve & Fitting Series

Betabite Fittings. Hardy Spicer, 1/9 Monterey Road, Dandenong South, Victoria, 3175 Toll free Ph:

Forged steel socket Welding fittings 6 ~ 13. Forged steel threaded fittings 14 ~ 20. Forged steel outlet fittings 21 ~ 23

PYPLOK System It s the weldless, threadless way to join pipe/tube

Tube Fitting Stainless SUS316 Series

Instrumentation Thread Fittings

10 Series Tube Fittings and Tubing

Minimal Fitting Series

Main Block Series. Concentrated Branching Joint for Assembly. Assembling Manifold Blocks for Concentrated Branching

TUBE & PIPE SECTION D

Swagelok Alternative Fuel Ser vice (AFS) Ball Valves

Needle Valves. Catalog 1203/1205 Aug 2012

Semiconductor / High Purity Products FITTINGS TK SCT. Weld Fittings / Metal Seal Fittings. SCT Division

Speed Controller High Flow

Flare Fittings. The World Standard. SAE 45 Flare. Inverted Flare. Access Valves

Medium- and High-Pressure Fittings, Tubing, Valves, and Accessories

Chlorine Valves and Accessories

SUPPLY JOINTS CONTENTS

T-Bar Bonnet. Monoflanges STANDARD OPTIONS. O.S.&Y. Bonnet (firesafe) Gas Solution Bonnet. Anti-Tamper Bonnet

Speed Controller with Uni One-touch Fitting Push-lock type. New-stand male threads for piping that reduces the screw-in time by 1/3. Model.

2200 North Main Street Washington, PA PH: FX:

Throttle (Needle) Valve PP Series

Series 105 Simplex Strainer Cast Iron Swing Bolt O-Ring Closure, Flanged Connection Class 125 ANSI Flat Face Flange Rating VENT 'A' FLOW

SECTION 2 SAFETY, TOOLS AND EQUIPMENT, SHOP PRACTICES UNIT 7: TUBING AND PIPING

Manifold Accessories. Catalog 4190-FP-ACC May 2007

Inline Adapters are Electro Polished to 10 Ra Max. 2 Valves supplied with Metal to Metal Face Seal connections have

Push-In Fitting Type Quick Exhaust Valve

Solution Partner. Leak - Proof Flow & Control. Check & Relief Valves. W e. s u p p o r t. t h e. i n n o v a t i o n s. o f.

M Tube Fitting Design Standards & Codes

Transcription:

ASM Accredited Nuclear & ISO900 Quality System ISO 900 Certified Fitting and Valve Manufacturer Catalog Number 0- January, 00 HYRAULIC SWAGING UNIT.HS-A Hydraulic Swaging Unit for Pre-Swaging Over

Certificates

Technical Information Introduction k-lok Tube Fittings have been designed specifically for the many demanding applications chemical, petroleum, power generating, pulp, paper and various types of manufacturing industries. They provide a highly reliable, leakproof and torque free seal on all tubing connections. k-lok Tube Fittings are commonly used on instrumentation, process and control systems or any other application where a high quality tube fitting is required Construction of k-lok Body Nut Thread Fittings Front Ferrule Back Ferrule Typical Raw Material List Fitting Material Stainless Steel Type Brass Carbon Steel Bar Stock Forging Tubing ASTM A79 ASTM A7 JIS G0 ASTM B Alloy 0 ASTM B5 Alloy 5 JIS H0 Alloy C0 JIS G05 S0C-SC ASTM A F JIS G ASTM B Alloy 77 JIS H0 Alloy C77 JIS G05 S0C-SC ASTM A9 ASTM A ASTM A9 ASTM B ASTM B75 ASTM B IN 7 ASTM A ASTM A79 IN 9 d Alloy 00 ASTM B ASTM B ASTM B5 k-lok Size No. 5 0 / 5/ A B Fractional Tube nd imensions Tube O.. k-lok Thread 5/-0UN -0UN 7/-0UNF -0UNF 9/-0UN -0UNF -0UNF -0UNF --0UN -5/-0UN Hex. Unit:mm A B d Hex..70 5...7....90. 5..00 7.7.5 9.0...0.0 7.0 0.0 5.70.0.0.0.0 5.0 7.0.0.0.0.0 k-lok Metric Tube nd imension Unit:mm Size Tube k-lok No. O.. Thread A B d Hex. M mm 5/-0UN.9 5...0 M mm -0UN.7...0 M mm 7/-0UNF 5. 7.7..0 M mm -0UNF....0 0M 0mm -0UN 7. 9.0 M mm -0UNF. 5M 5mm -0UNF.9.0 M mm -0UNF.7.0 M mm -0UNF 5. 0.0 0M 0mm --0UN.0 5.9.0 M mm --0UN.0..0 M mm -5/-0UN..5..0 Standard of Quality for k-lok Fittings The k-lok body, nut, back ferrule and front ferrule are manufactured under very close tolerance control and monitored through Statistic Process Control and are Heat- Code Traceable. The twin ferrule design performs leak proof sealing with all assembly and reassembly motion being transmitted axially through the tubing. This results in no radial movement of the tubing upon assembly and reassembly. Therefore, the tubing is not stressed and the mechanical integrity is maintained. This is the result of close tolerance control in machining, surface smoothness and hardness of each and every part of the k-lok tube fitting. Through this swaging action, the k-lok fitting becomes integrated mechanically with the tubing connected. k-lod fittings are available in Stainless Steel, Brass and Carbon Steel as standard materials, and can be manufactured from various materials upon request. k-lok fittings are tested according to JIS B5 & BS standards. Tubing & Tube Fitting Benefits Tubing has many benefits over piping. Since tubing is able to be bent, this allows lower pressure drop due to fewer connections. This in turn reduces costs because of less fabricating manpower. k-lok connections do not require threading or welding, and are assembled by standard wrench make-up. This results in less assembly and maintenance costs. Tubing Selection For safe, reliable and leak-free seals, tubing should be considered as a fitting component. Quality k-lok fittings provide the best performance when good tubing is used. Care should be taken and general rules followed to have good tubing connections. Copyright 00, Ktech, All Rights Reserved.

Tubing - General Rules Tubing Temperature Ratings. For leak-free sealing, the tubing surface is very important. The Tubing must have a good surface free from scratches, draw mark, flat spots or dirt.. In case of welded tubing, it should not have a visible poor bead on its outside diameter.. Using like tubing and fitting material is essential for the same thermal compatibility and corrosion resistance. The tubing material should be compatible with the process fluid, temperature and environment.. Tubing must be softer than fitting material. When tubing and fittings are made of the same material, the metal tubing must be fully annealed. 5. Tubing hardness must be selected according to the information in the table to.. o not select a too thin or thick wall. A too thin wall may collapse and a too thick wall may not properly be deformed by the ferrule action. The wall thickness selection should be based on the applicable pressure, temperature, shock and vibration. 7. Tubing with oval or out-of-roundness appearance may not fit into the fitting. o not force the tubing into the fitting, it may damage the fitting sealing system of the nut, ferrules, or the body. Purchasing the tubing based on the industrial standards such as ASTM or other equivalent specifications doesn't mean that you have the right tubing when we see other variables. See variables below for taking care of your tubing. Material Grade. Weld or Seamless. O.. and Tolerance. Wall thickness and Tolerance 5. Hardness. Ovality (Shape) 7. Concentricity. Surface finish Tube cutting and de-burr both ends Use tube cutter for straight cutting of tubing and clean metal chips from both I.. and O.. of the tube with deburring tool. Hacksaw can be used for cutting improper size by tube cutter and hacksaw blades should have at least teeth per inch. The Maximum and Minimum operating temperatures for various tubing material Tubing Material Stainless Steel Carbon Steel Copper Alloy 00 Alloy C7 Alloy 00 Titanium Teflon Temperature e-rating Factors Temperature Range - F to 00 F (-9 C to 9 C) -5 F to 799 F (-5 C to C) -0 F to 00 F (-0 C to 05 C) - F to 00 F (-9 C to 7 C) -0 F to 000 F (-95 C to 57 C) -05 F to 00 F (-0 C to C) -0 F to 00 F (-95 C to 5 C) -0 F to 50 F (-7 C to 5 C) The allowable working pressure is determined by various temperatures. To determine the working pressure at the specific temperatures, multiply the working pressure at ambient temperature shown in table ~ by the factor shown in table. xample : Tube SS O.. x 0.05 at 700 F. 500psi x 0. = psi. Therefore psi is the maximum allowable working pressure of SS O.. x 0.05 wall tubing. Table. Temperature e-rating Factors Temp. F( C) 00 () 00 (9) 00 (9) 00 (0) 500 (0) 00 () 700 (7) 00 (7) 900 () 000 (5) 00 (9) Stainless Steel ASTM A9 0.00.00.00.00.00.00 0.9 0.9 0.7 0.90 0. 0.5 0.0 0. 0.7 0.79 0.7 0.7 0.9 0.7 0.0 0.7 C. Steel ASTM A79.00 0.95 0.90 0. 0. 0.77 0.7 0.59 - - - Copper ASTM B75.00 0.0 0.7 0.50 0. - - - - - - Alloy 00.00 0. 0. 0.79 0.79 0.79 0.7 0.7 - - - Tube bending Bendability is one of tubing benefits against piping, this causes fewer connections therefore fewer leaks potentiality of the system. Proper tube bending practices ensure against potential leaks of hazards. * Bend prior to installing fittings. * Use tube bender, o not bend a tube placed in the fitting. * o not bend close to fitting, allow a certain straight distance from fitting to the starting point of tube bend. For further details, see page 5. Allowable working temperature When lastomer seal is used in the fitting, care must be taken for allowable working temperature. See working temperature below. lastomer seal material NBR (e. g. Perbunan ) FKM (e. g. Viton ) PTF (e. g. Teflon ) Working Temperature -0 C to 0 C (-0 F to 0 F) - C to 0 C (-0 F to 00 F) -0 C to 0 C (-7 F to F)

Stainless Steel Tubing Fully annealed 0 or seamless to ASTM A9 or equivalent, suitable for bending and flaring. Hardness : Rb 0 or less Table. For Seamless Stainless Steel Fractional Tubing (Inches) / / 5/ - - Table. For Seamless Stainless Steel Metric Tubing (mm) 0 5 0 0 Tube wall Thickness in Inches 0.0 0.0 0.0 0.00 0.0 0.05 0.09 0.05 0.0 0.095 0.09 0.0 0. 0.5 0.,00,00 9,00,000,500 5,00,000 70 0 0 0 0 00 0 70 50 0 00 0 0 00 90 70 50 0 70 90 0 0 0 0 0 0 90 70 0,900 7,000 0,00 5,00,000,00,00 7,500 5,00,00,500,900,00,000 0,00,000,500,700,000,00,00,00 0 0 0 00 0 0 0 0 0 90 0 0 90 0 0 00 0 70 0 Working pressures are based on allowable stress value of 0,000PSI (7,00kPa=,7bar) as specified by ASM B.-999 over the temperature range of -9 C to C (-0 F to 00 F). Safety Factor =.75:, considering ultimate tensile strength 75,000PSI (5,700kPa=5,7bar) Pressure calculations are based on maximum O.. and minimum wall thickness and no allowance is made for corrosion and erosion. e.g. ASTM A9 Ox0.05: O tolerance 0.005",W.T. 0%. Calculations are based on 0.505"Ox0.05" W.T. To determine Bar, multiply PSIG by 0.09. To determine kpa, multiply PSIG by.9, To convert bar to PSIG, multiply bar by.5 For working pressure per ASM B., multiply value by 0.9 0 00 70 0 90 0 0 00 90 70 0,00 5,00,00,00,00,00 70 0 00 0 0 0 00 70,000,900,00,00,00,00 0 0 00 0 0 0 90 5,00,00,00,00,700,000,700,00,000,00 0 0 0 0 00 Working Pressure in Psig,00,900,00,000,500,900 0 0 90 0,900,00 Tube Wall Thickness in Millimeters 0..0..5..0..5..0.5.0.5 Working Pressure in Bar 0 0 0

Welded Stainless Steel Tubing Based on ASM B. - 999 for weld integrity a de-rating factor must be applied to welded tubing. For double butt seam tubing multiply by 0.5 and for single butt seam tubing multiply by 0.0. Copper Tubing Soft annealed seamless to ASTM B75 or equivalent. Hardness : Rb 0 or less Table. For Seamless Copper Fractional Tubing (Inches) / 5/ Tube Wall Thickness in Inches 0.00 0.0 0.0 0.05 0.09 0.05 0.0 0.095 0.09 0.0,700,00,00,00,00,00,00,000 00,00,500,900,00,00 900 700 00 500,500,700,00,00,00,000 00 700,00,00,00,00 900,900,500,00,00 Working Pressure in Psig,00,500,00,500 Table 5. For Seamless Copper Metric Tubing (mm) 0 Tube Wall Thickness in Millimeters 0.7 0..0..5...0..5.0 5 5 0 9 9 70 5 57 9 7 5 9 95 9 0 09 9 7 5 7 5 79 0 9 7 59 5 9 50 0 9 79 5 7 0 0 90 7 9 5 0 7 Working Pressure in Bar 7 90 7 7 7 9 0 90 09 0 59 0 Working pressures are based on allowable stress value of,000psi ( bar=,00kpa) as specified by ASM B.-999 over the temperature range of 9 C to C (-0 F to 00 F). Safety Factor=5:, considering ultimate tensile strength 0,000PSI (07 bar=0,700kpa) Pressure calculations are based on maximum O.. and minimum wall thickness and no allowance is made for corrosion and erosion For working pressure per ASM B., multiply value by 0.9

Carbon Steel Tubing Soft annealed seamless to ASTM A79 or equivalent, free from scratches, suitable for bending & flaring. Hardness: Rb7 or less. Table. For Seamless Carbon Steel Fractional Tubing (Inches) / 5/ - - Tube Wall Thickness in Inches 0.0 0.05 0.09 0.05 0.0 0.095 0.09 0.0 0. 0. 0.5 0.0 0.0 Table 7. For Seamless Carbon Steel Metric Tubing (mm) 0 5 0 0,000 5,00,700 70 0 0,00,00,700,00,00,00,00 0 00 90 0 90 0 50 9,00 7,000 5,500,500,00,00,00,00,500 90 0 0 0 90 0 70 50 0 0 9,00 7,00,00,500,500,900,00,00,00 0 0 0 90 0 0 0 90 70 50 5,900,00,700,00,700,00,00 0 00 0 0 0 00 0 0 5,00,00,700,00,500,000,500 0 0 0 90 0 0 0 0 0 50 0 5,00,00,700,900,00,700 50 0 50 0 90 0 0 00 0 0 50 0,00,00,00,900 0 0 90 0 0 00 90 70 0,00,000,00 0 00 0 0 0 00 0 Working Pressure in Psig,000,00,00 0 0 0 0 0,00,700,700 90 70 0 0 5,000,00,000 Tube Wall Thickness in Millimeters 0..0..5..0..5..0.5.0.5 Working Pressure in Bar Working pressures are based on allowable stress value of 5,700PSI (0 bar=0,00kpa) as specified by ASM B.-999 over the temperature range of -9 C to C (-0 F to 00 F). Safety Factor =.75:, considering ultimate tensile strength 7,000PSI (7 bar=,700kpa). Pressure calculations are based on maximum O.. and minimum wall thickness and no allowance is made for corrosion and erosion. For working pressure per ASM B., multiply value by 0.9 5,00,700 90 0 0

Alloy 00 Tubing Fully annealed seamless Alloy 00 tubing to ASTM B5 or equivalent. Hardness:Rb75 or less Table. For Seamless Alloy 00 Fractional tubing (Inches) Tube Wall Thickness in Inches 0.0 0.05 0.09 0.05 0.0 0.095 0.09 0.0 7,900,700 0,00,00 7,000 9,00 Working Pressure in Psig,00,00,00,00,00,00,00,000,000,00,00,900,00,900,00 Working pressures are based on allowable stress value of,700psi (,00kPa=bar) as specified by ASM B.-999 over the temperature range of -9 C to C (-0 F to 00 F). Safety Factor =.75:, considering ultimate tensile strength 70,000PSI (,00kPa=,bar) Pressure calculations are based on maximum O.. and minimum wall thickness and no allowance is made for corrosion and erosion. For working pressure per ASM B., multiply value by 0.9 Special Alloy Tubing When Special Alloy Tubing is Selected, we recommend : Fully Annealed Seamless(or Welded and Cold-draw, where permitted) Alloy Tubing to the ASTM specification as shown below. Tubing should be free of scratches for bending or flaring. k-lok material esignator HC IN Ti Tube Material Alloy C7 Alloy 00 Titanium - Grade B B7 B Pressure Rating quivalents : ASTM Number Tubing Type Maximum Hardness Seamless RB 90 Seamless RB 90 Seamless or Welded RB 90 ) bar = 00 kpa =.5 psi ) kpa = 0.0 bar = 0.5 psi ) psi = 0.09 bar =.9 kpa ) kg/cm = 0.9 bar =. psi Tubing for Gas application K-Lok tube fittings are designed for a wide range of leak-free application including gas leak proof and vacuum service. Gases can escape even the most minute leakpath due to their small molecules, Tube must therefore be carefully handled not to get scratched. Use heavier wall tubing for gas service. Heavy wall tubing resists ferrule action by coining out minor defects of the tube surface and thin wall tubes may collapse with little resistance to ferrule action. For Gas service, use the tubing of the un-shadowed section in table 5 -. Cryogenic Service K- Lok Fittings in S Stainless Steel provide highly reliable performance from Cryogenic Temperatures to High Temperature Levels. S Stainless Steel Temperature Rating : - F to 00 F (-9 C to 9 C) Cryogenic Temperature are considered to be Temperatures Below : -00 F (-7 C)

Pipe Thread Many k-lok tube fittings have a male or female pipe end. These ends sometimes have a lower pressure rating than the pressure rating of the tube fitting end. Table 9. Pipe nd Pressure Rating Size esignator 0 ISO/NPT Pipe Size / - - Male pisg bar,000 0,000,00 0,000 7,00 7,500 5,00,00 5,00,000 Stainless Steel Brass Carbon Steel 95 9 57 9 57 57 5 7 5 7 Female pisg bar,00,00,500 5,00,00,00,00 5,000,500,900 55 5 7 0 5 0 9 Male pisg bar 7,00 5,000,00 5,00,900,700,00,00,500,000 50 5 5 9 5 79 7 Female pisg bar,00,00,00,00,00,00,00,500,00,900 7 0 0 79 5 5 5 7 5 Male pisg bar,000 0,000,00 0,000 7,00 7,500 5,00,00 5,00,000 95 9 57 9 57 57 5 7 5 7 Female pisg bar The ratings shown above are based on ASM B.-999 Female pipe ends have lower ratings than male pipe in a given size due to the inner and outer diameters of female threads being larger than those of male pipe ends. The ratings shown above are reference only.,00,00,500 5,00,00,00,00 5,000,500,900 55 5 7 0 5 0 9 Pipe Thread Sealant Pipe thread sealant is essential to ensure leak-free seal. Since the Teflon tape is commonly used, we provide information of recommended tape width, as well as the numbers of thread to be wrapped. The Teflon TM tape fills the voids between threads and prevents galling on pipe threads. The sealant usually contains a lubricant. Table 0. Nominal Pipe Size Recommended Tape Width - - - - * ASM B.0.-NPT ffective Thread Length (xternal) L* 0.9 0.0 0.075 0.57 0.557 0. Approx.# of Thread 7 7-7-/ 7-7-/ Unit : Inches Note:. Wrap Teflon TM Tape clockwise from first thread. o not overhang the first thread, as the tape may get into the fluid system.. Teflon TM tape has a temperature limit of 0 C( 50 F). Note: The information shown in table -0 are not for design purpose, but for reference only. The accuracy of information is not the liability of our company.

Ordering Information k-lok tube fittings are ordered by the part number which is constructed as per SA recommended practice.. Tube to Pipe ends xample : MC -N-B k-lok Male Connector. x Male NPT, Brass. MC - N - B k-lok designated as Name of Fittings : See fitting type designator : See tube O.. designator Pipe thread size : See pipe thread designator Pipe thread Symbols : See pipe thread symbol Material : See fitting material designator. Tube to Tube ends xample : U--S k-lok Union material S T - - S. Tee & Cross Tees are described by first the run ( and ) and next the branch ( ). Stepped Shoulder of k-lok Metric Tube Fittings Metric k-lok is obviously different from Fractional with the stepped shoulders machined on Nut and fitting body. Crosses are described by first the run ( and ) and next the branch ( and ). Metric K-Lok Tube Fittings Metric Tube nd Stepped Shoulders Constructed on Nut, Fittings Body

Fitting type esignator Identifier escription Identifier escription U Union AF Female Adapter L Union lbow CP Port Connector UR Reducing Union CRP Reducing Port Connector T Union Tee UA AN Union X Union Cross UBA AN Bulkhead Union UB Bulkhead Union AA AN Adapter MCT Thermocouple Connector MCS SA Male Connector MC-N Male Connector LS SA Male lbow MC-R Male Connector LBS 5 SA Male lbow MC-G Male Connector for Bonded Seal TRS SA Male Run Tee OM Male Connector for Metal Gasket TBS SA Male Branch Tee MCB Bulkhead Male Connector COS O-Seal Straight Thread Connector LBM 5 Male lbow COP O-Seal Pipe Thread Connector LM Male lbow CW Male Pipe Weld Connector TRM Male Run Tee LW Male Pipe Weld lbow TBM Male Branch Tee CSW Tube Socket Weld Connector CF Female Connector LSW Tube Socket Weld lbow CG Gauge Connector P Plug CBF Bulkhead Female Connector C Cap LF Female lbow I Tube Insert TRF Female Run Tee N Nut TBF Female Branch Tee FF Front Ferrule R Reducer FB Back Ferrule AB Bulkhead Adapter FS Ferrule Set AM Male Adapter HS-A k-lok Hydraulic Swaging Unit esignator Inch O.. Identifier Metric O.. Identifier / mm M mm M / mm M mm M 5/ 5 mm M 0mm 0M mm M 0 mm M 0mm 0M mm M mm M - 0 mm M - mm M mm M Pipe Thread Size esignator Fitting Material esignator Nom. Size Identifier - - 0 Material Identifier SS S SSL L SS0 C.Steel C Brass B Alloy00 M Pipe Thread Symbol Type Taper Threads Parallel Threads Symbol R N G U Specification ISO 7/, BS(BSPT), JIS B 00 (PT), IN999 ANSI N.0. (NPT) ISO/, BS 779(BSPP), JIS B00(PF) American Standard Unified Screw Threads

Introducing the Z-Series Single Ferrule Technology from k-lok Z-Series Fitting Ordering Using cutting-edge engineering, k-lok has designed and manufactured Z-Series Single Ferrule Fittings to the highest quality standards Leak-Free Z-Series Nuts and Ferrules are designed to use with the k-lok Tube Fitting Body. Features include: Single Ferrule esign Corrosion Resistance Ferrule Fine Molybdenum isulfide (MoS) coated Nut to prevent galling and additional thread lubricant Positive leak-free seal Standard S and Brass Materials Materials, Pressure Ratings, Installation and Tubing Selection. Materials of the k-lok Z-Series Nut and Ferrule, Pressure ratings (when connected with Tubing), Installation and Tubing selections are identical to those of k-lok Tube Fittings. Please refer to a k-lok catalog for additional information FZ-Ferrule Ferrule Part No. FZ- Tube O.. FZ- FZ- FZ- FZ- NZ-Nut Nut Part Tube Hex L No. O.. H inch NZ- 9/ 0.50 NZ- / 0.5 NZ- / 0.9 NZ- - 0.9 NZ- - 0. Identifier escription UZ Union LZ Union lbow URZ Reducing Union TZ Union Tee XZ Union Cross UBZ Bulkhead Union MCZ- N Male Connector MCZ- R Male Connector MCTZ Thermocouple Connector MCZ- G Male Connector for Bonded Seal OMZ Male Connector for Metal Gasket MCBZ Bulkhead Male Connector LBMZ 5 Male lbow LMZ Male lbow TRMZ Male Run Tee TBMZ Male Branch Tee CFZ Female Connector CGZ Gauge Connector CBFZ Bulkhead Female Connector LFZ Female lbow TRFZ Female Run Tee TBFZ Female Branch Tee RZ Reducer ABZ Bulkhead Adapter AMZ Male Adapter AFZ Female Adapter CPZ Port Connector UAZ AN Union UBAZ AN Bulkhead Union AAZ AN Adapter MCSZ SA Male Connector LSZ Positionable SA Male lbow LBSZ Positionable 5 SA Male lbow TRSZ Positionable SA Male Run Tee TBSZ Positionable SA Male Branch Tee COSZ O-Seal Straight Thread Connector COPZ O-Seal Pipe Thread Connector CWZ Male Pipe Weld Connector LWZ Male Pipe Weld lbow CSWZ Tube Socket Weld Connector LSWZ Tube Socket Weld lbow PZ Plug CZ Cap NZ Nut FZ Ferrule All the Assembly imensions are ldentical to those of k-lok fittings. For Additional etails, Please Refer to the imensional Table of each Fitting

Union U Union lbow L Tube to Tube Union Reducing Union UR Union Tee T Union Cross X Bulkhead Union UB Male Connector MC-N Male Connector Vent Protector M Bulkhead Male Connector MCB 5 Male lbow LBM Male lbow LM Male Run Tee TRM Tube to Male Pipe MC-R Thermocouple Connector MCT Male Connector for Bonded Seal MC-G Male Connector for Metal Gasket OM Male Branch Tee TBM Tube to Female Pipe Female Connector CF 5, 7 9 0, 7, 9,0,, Gauge Connector CG Bulkhead Female Connector CBF Female lbow LF Female Run Tee TRF Female Branch Tee TBF Reducer R Bulkhead Adapter AB Male Adapter AM Female Adapter AF Port Connector CP AN Union UA AN Adapter AA Stub Tube Connector Reducing Port Connector CRP AN Bulkhead Union UBA Tube to AN Tube 5 SA Male Run Tee TRS 5 7 9,0, Tube to SA O-Ring Seal SA Male Connector MCS Positionable SA Male lbow LS Positionable 5 SA Male lbow LBS 5 5 5 7 7 Positionable Positionable SA Male Branch Tee TBS O-Seal Straight Thread Connector COS O-Seal Pipe Thread Connector COP Tube to Weld nd Male Pipe Weld Connector CW Male Pipe Weld lbow LW Tube Socket Weld Connector CSW Tube Socket Weld lbow LSW Plug P Cap C Tube Insert I Nut N Front Ferrule FF Back Ferrule FB Ferrule Set FS Gap Gauge IG Swaging Unit HS-A Plug and Cap Spare Parts 50 50 5 5 5 5 5 5 5 5 55 55 55 55 5

Union U Connects fractional tube U- U- U- U- U-5 U- U- U-0 U- U- U- U-0 U- U- h H A B in mm in mm in mm / / 5/ - -.59.7.7 5.7 9.05..75.0 50.0.7..0. 7. 0. 5.7..5 7..0 5.97 5/ 7/ 7/ 9/ / 5/ -/ -/ - - - -... 5.7 0...9 0..9.5 5.97 5/ 7/ 9/ / - - - - -.. 5.7 7...5.75.0 7. 57.5 7.0..7 5...7....90.. 50.0 7.5 0.9 5..00 7.7.5 9.0.. 5..7 7.50.5...9 0. 0.9.75.7 5.05 0..00 5.0 7.70.5 5.5 7. 0.9.9.95 5.0 5.07 5.59 55.7.77 9.0 05 Connects metric tube U-M U-M U-M U-M U-M U-0M U-M U-5M U-M U-M U-0M U-M U-M U-M U-M U-M 0 5 0.7.....9.7 5. 5.9.....7 h H 5 7 0 0 5 55 9 0 50 0 A B L.9.9.7 5.. 7...0.0...0 9. 5. 5.. 7.7..5........0.0..... 0.. 5. 5. 5. 5. 7..0.. 5. 5.0 5.0 5.5 55.0 55.0 5.0 5.0 97..

Union lbow L Connects fractional tube L- L- L- L- L-5 L- L- L-0 L- L- L- L-0 L- L- h H A B in mm in mm in mm / / 5/ - -.59.7.7 5.7 9.05..75.0 50.0.7..0. 7. 0. 5.7..5 7..0 5.97 9/ / 5/ -/ - - -/ -. 5.7 0...9.9.9. 50.0 5/ 7/ 9/ / - - - - -.. 5.7 7...5.75.0 7. 57.5 7.0..7 5...7....90.. 50.0 7.5 0.9 5..00 7.7.5 9.0.. 5..7.00 5.7 7.7 5...90.70 9.7.5..50 50.0 9.0 7..5..9.70 0..0.0 9.7.70 9.0.5 77 07. Connects metric tube L - M L - M L - M L - M L - M L - 0M L - M L - 5M L - M L - M L - 0M L - M L - M L - M L - M L - M 0 5 0.7.....9.7 5. 5.9.....7 h H.7.7. 7.5 0... 7.0.9.9.9.0.0 55.0 9 0 50 0 A B L.9.9.7 5.. 7...0.0...0 9. 5. 5.. 7.7..5.. 5.7 5.7. 9...9.9.7.7 9.7.5.5.. 9. 5.... 7.0..5.0.. 9... 9..0 7..0

Reducing Union UR Connects fractional tube h H H A A B B in mm in mm in mm in mm in mm UR - UR - UR - UR - UR - UR - UR 5- UR 5- UR - UR - UR - UR -5 UR - UR - UR - UR 0- UR 0- UR - UR - UR - UR -0 UR - UR - / / 5/ 5/..7.7 5.7 5.7 9.05 9.05 9.05 9.05 / / / / / 5/.59.59.7.59.7.7.7.59.7.7 5.7 9.05.7.7..7..0...7.... 7. 7. 0.. 7. 0. 0. 5.7 7/ 7/ 7/ 9/ 9/ / / / 5/ 5/ -/ -/ -/ -/ - -..... 5.7 5.7 5.7 5.7 0. 0. 0....9.9.9.9.9.9 7/ 9/ 9/ 9/ / / / / - - - - - -.... 5.7 5.7 7. 7. 7. 7.....57.57.57.57.0.0 5/ 5/ 7/ 5/ 7/ 7/ 9/ 5/ 7/ 9/ 7/ 9/ / / 9/ / -...... 5.7.. 7. 7... 7....5.7.7 5. 5. 5....7.7.7.7...............7 5.. 5.. 5..7.7. 5..7.... 5..00.00 7.7 7.7 7.7.5.5 9.0 9.0 9.0 9.0.. 0.9 0.9 5. 0.9 5..00 5. 7.7 0.9 5. 7.7.5 5. 7.7 9.0 9.0 7.7 9.0 0.0....90 7..9. 9.. 9. 0.9.75.75.75.7.7.7 0.9 0. 0.9..57.9.0 9.7 9.7..57 0.9..9 5..99.5 9.7 5.07 9.7 50.0 5.59 5.59..7

Reducing Union UR Connects metric tube h H H A A B B UR M-M UR M-M UR M-M UR M-M UR M-M UR 0M-M UR 0M-M UR M-M UR M-M UR M-0M UR M-0M UR M-M UR M-M UR M-M UR M-0M 0 0 0 0 0.7.7....... 5. 5.9 5 7 5 5 9 9 0 9 9 0.9 5. 5. 5.. 7. 7.......9.9.9.7 5. 5.. 5.. 7. 7....0 5. 7.7 7.7 7.7..5.5 5. 5. 5.. 7.7 7.7. 7.7..... 7. 0.0 0..0.... 9.9 5... 9...5 5. 7.0 7..7 5.0 5.5.0. Connects metric tube to fractional tube UR M- UR M- UR M- UR M- UR M- UR M-5 UR M- UR 0M- UR 0M- UR 0M-5 UR 0M- UR M-5 UR M- UR M- UR 5M- UR M-0 UR M- UR 0M- UR 0M- UR M- 0 0 0 0 5 0 0 in 5/ 5/ 5/ mm.7.7.7.7 5.7 9.05 9.05.......... 7.. 7. 0..7 5. 5.9 5.9. h 5 7 0.9.9 H 9 9 9 9 0 H..... 5.9... 5.9 7.5 5.9 7.5....... A.9.7.7 5. 5. 5.. 7. 7. 7. 7.....0.0.0 A.. 5.. 5.. 5.. 5...9..9.... B 5... 7.7 7.7 7.7. B 5. 5. 7.7 5. 7.7. 7.7 5. 7.7... 9........ 7. 7. 7.7 0..0 0..0.0.....0. 5..5 9..5.0....5 5. 5.9 7.. 5. 5.0 5.0 5.5 5.9 0. 0.

Union Tee T Connects fractional tube T- T- T- T- T-5 T- T- T-0 T- T- T- T-0 T- T- h H A B in mm in mm in mm.59.7 5/..7. 7/..7.0.7. 9/. 5. 9/. 5.7. 7. 5.7 / 7..7 0. / 0... 5.7 5/.. 9.05 5.7 -/.9 -.5... -.9 -.75.90.5 -.9 -.0..75 7. -/. - 7...0.0 50.0-57.5 50.0 50.0 5.97-7.0 7.5 / / 5/ - - 0.9 5..00 7.7.5 9.0.. 5..7.00 5.7 7.7 5...90.70 9.7.5..50 50.0 9.0 7..5..9.70 0..0.0 9.7.70 9.0.5 77 07. Connects metric tube T - M T - M T - M T - M T - M T - 0M T - M T - 5M T - M T - M T - 0M T - M T - M T - M T - M T - M 0 5 0.7.....9.7 5. 5.9.....7 h H.7.7. 7.5 0... 7.0.9.9.9.0.0 55.0 9 0 50 0 A.9.9.7 5.. 7...0.0...0 9. B 5. 5.. 7.7..5.. 5.7 5.7. 9...9.9.7.7 9.7.5.5.. 9. 5.... 7.0..5.0.. 9... 9..0 7..0

Union Cross X Note : Cross may be made from plate stock Connects fractional tube X- X- X- X- X-5 X- X- X-0 X- X- X- X-0 X- X- h H A B in mm in mm in mm / / 5/ - -.59.7.7 5.7 9.05..75.0 50.0.7..0. 7. 0. 5.7..5 7..0 5.97 9/ / 5/ -/ - - -/ -. 5.7 0...9.9.9. 50.0 5/ 7/ 9/ / - - - - -.. 5.7 7...5.75.0 7. 57.5 7.0..7 5...7....90.. 50.0 7.5 0.9 5..00 7.7.5 9.0.. 5..7.00 5.7 7.7 5...90.70 9.7.5..50 50.0 9.0 7..5..9.70 0..0.0 9.7.70 9.0.5 77 07. Connects metric tube X-M X-M X-M X-M X-0M X-M X-5M X-M X-M X-0M X-M X-M X-M X-M X-M A B h H 0 5 0.....9.7 5. 5.9.....7.7.7. 7.5 0... 7.0.9.9.9.0.0 55.0 9 0 50 0.9.7 5.. 7...0.0...0 9. 5.. 7.7..5.. 5.7. 9...9.9.7.7 9.7.5.5.. 9. 5... 7.0..5.0.. 9... 9..0 7..0

Bulkhead Union UB Connects fractional tube UB- UB- UB- UB- UB-5 UB- UB- UB-0 UB- UB- UB- UB-0 UB- UB- Panel h H A B Hole rill size in mm in mm in mm / / 5/ - -.59.7.7 5.7 9.05..75.0 50.0.7..0. 7. 0. 5.7..5 7..0 5.97 5/ 9/ / 5/ -/ -/ - - - - -. 5.7 7. 9.05..9 0..9.7 7. 57.5 5/ 7/ 9/ / - - - - -.. 5.7 7...5.75.0 7. 57.5 7.0..7 5...7....90.. 50.0 7.5 0.9 5..00 7.7.5 9.0.. 5..7.7.0 0..9 5.97 50.0 5. 5.7. 7.7 9. 05..... 9..75.5 7..9 5. 7.75 9.7 5..50 5.0 5.59 57.5 0.70. 7. 7. 9.5 95.75.9 9.9 0. 7.7..00.5 5...9.7 5.0 57.0 7.5 9.7 5.. 9.9.50.09. 9...79.97.7.7 9. 5 Panel Max Thickness.05 0..7.7.7 9.05 9.05 9.05 9.05 9.05 Connects metric tube UB - M UB - M UB - M UB - M UB - 0M UB - M UB - 5M UB - M UB - M UB - 0M UB - M UB - M UB - M UB - M 0 5 0.....9.7 5. 5.9....7 h 7 7 0 5 5. 50 0 H 9 0 50 0 A B.9.7 5.. 7...0.0..0 9. 5.. 7.7..5.. 0..9.0.5 50. 5. 5. 5.7.. 7.. 9..... 9...5.5 7..9.9 5. 5.5 5. 5. 57.7.0.7 7.0 7.5 7.5.5.5 95.9....0.. 7.0.9.. 7. 5.0 5.0 57.5 7.5 79. Panel Hole rill size. 9.9.5.....0 9.0 9.0.7.5 50.5 Panel Max Thickness.7.7 0....7.7.7. 7.0 9. 9. 9.0 9.0

Male Connector MC-N Connects fractional tube to female NPT thread MC -N MC -N MC -N MC -N MC -N MC -N MC -N MC -N MC -N MC -N MC -N MC -N MC -N MC -N MC -N MC -N MC 5-N MC 5-N MC 5-N MC 5-N MC -N MC -N MC -N MC -N MC -N MC -N MC -N MC -N MC -N MC -N MC -N MC 0-N MC 0-N MC 0-N MC -N MC -N MC -N MC -N MC -N MC -N MC -N MC -N MC 0-N MC 0-0N MC 0-N MC -0N MC -N MC -N MC -N MC -0N MC -N MC -N in mm / / / / / 5/ 5/ 5/ 5/ - - - - - -.59.59.59.7.7.7.7.7.7.7 5.7 5.7 5.7 9.05 9.05 9.05...75.75.75.0.0.0 50.0 50.0 50.0 50.0 T (NPT) / / / - - - - - -.7.7.7......0.0........ 7. 7. 7. 7.. 7. 0. 0. 0..9.9 5.7 5.7 5.7..9 5.7.5.5 7. 7. 7..0.0.9 5.97 5.97 5.97 h H A B in mm in mm 5/ 7/ 9/ 7/ 7/ 9/ / 7/ 9/ 9/ / -/ 9/ 9/ / / -/ / / / -/ - 5/ 5/ -/ -/ -/ - -/ - - - - - - - - - - - - - -..... 7..... 7...9.. 7.. 5.7 5.7 7...9 0. 0. 0...9.9...9.9.9.9 0..9.9.9.9.5.5.5 5.9 5.9 5/ 5/ 5/ 7/ 7/ 7/ 7/ 7/ 9/ 9/ 9/ 9/ 9/ 9/ / / / / / - - - - - - - - - - - - - -........... 5.7 5.7 5.7 5.7 7. 7. 7. 7. 7........5.5.5.75.75.0.0.0 7. 7. 7. 57.5 57.5 57.5 7.0 7.0 7.0 7.0....7.7 5. 5. 5. 5. 5. 5......7.7.7.7.7.............90.90...... 50.0 50.0 50.0 7.5 7.5 7.5 7.5 0.9 0.9 0.9 5. 5. 5. 5. 5..00.00 7.7 7.7 7.7 7.7 7.7 7.7.5.5.5.5 9.0 9.0 9.0 9.0 9.0...... 5. 5. 5..7.7.7.7 0.00.5 7.7..7.95 9. 5.5. 9.7 0. 0.9 7...7..75..5.5. 0..70.7.7. 0..99.0. 0. 0. 0..99 0..99 5. 5. 50.0 55. 55. 0.5 59..7..0 7.0 75.50 7.0.. 0.9 9.7 0. 5.5 5.....7.7 7..5.70..0.0 9. 5.0 5.0 9.7 9.7. 7.75... 9.0 50.5 57.5.9 9.0 50.5 50.5 50.5 57.5 50.5 57.5 57.0 57.0. 77. 77...0.90 99.75 05.7 0.7..5

Male Connector MC-R Connects metric tube to female ISO tapered thread MC M - R MC M - R MC M - R MC M - R MC M - R MC M - R MC M - R MC M - R MC M - R MC M - R MC M - R MC M - R MC M - R MC 0M - R MC 0M - R MC 0M - R MC 0M - R MC M - R MC M - R MC M - R MC M - R MC 5M - R MC M - R MC M - R MC M - R MC M - R MC M - R MC M - R MC 0M - R MC 0M - R MC M - R MC M - R MC M - R MC M - R MC M - R MC M - 0R MC M - 0R MC M - R 0 0 0 0 5 0 0 T R(PT) - - -.7............. 7. 7..9 7..9.7.9 5..9 5.9 5.9. 5.9.....7 h H 5 5 9 9 9 9 7 7 7 0 7 0 0 0 0 5 5 5 50 55 0 A.9.9.9.7.7 5. 5. 5. 5..... 7. 7. 7. 7......0.0.0.0.....0 9. B 5. 5. 5... 7.7 7.7 7.7 7.7.....5.5....9. 9.0. 9.7. 0..0 7..7.. 7..7.......9.9.0.0.9.9 0. 0.... 7. 5. 50.0 5. 5. 5..0 0.5 9.7 5.... 7...0..7 9... 0.9 0.9 5.7... 9.0 9.0.. 9.0 9.0 50.5 50.5 5. 5. 5. 5 57.5. 7. 7. 79. 9. Thermocouple Connector MCT k-lok thermocouple connector has no shoulder nor sizing angle inside the fitting, the features enable thermocoupler to go through fitting's thread end. Suffix "T" to Male Connector identifier. xample : MCT -N-S for ordering Thermocouple connector O.. " x " NPT S. Assembly Instructions. Position the length of the Thermocouple passed through fitting's thread end and hold it to prevent shifting during assembly.. Turn the nut - after finger tight with a wrench by holding the body with a back up wrench for size " (mm) or above.

Male Connector for Bonded Seal MC-G Connects fractional tube to female ISO parallel thread MC -G MC -G MC -G MC -G MC -G MC -G MC -G MC -G MC -G MC -G MC -G MC -G MC -G MC -G MC -G MC -G MC -G MC 0-0G MC -G T h H (PF) in mm in mm in mm.7. 9/. 7/..7. 9.05 7/..7.. 7/.. 9/. 9/.. 9.05 9/... 9/.. -/.9 9/.. 9.05 / 7. 7.. / 7. 7. -/.9 / 7. 7. / 0.... 0. -/.9. 9.05.9 -/.9 -.5 9.05 5.7-5/. -.5.9 -.9 -.0.5 -.7 -.0 -.75-7. 50.0-7. -.0 -.0-57.5-57.5 Connects metric tube to female ISO parallel thread MC M-G MC M-G MC M-G MC M-G MC M-G MC M-G MC M-G MC M-G MC M-G MC M-G MC M-G MC M-G MC M-G MC 0M-G MC 0M-G MC 0M-G MC M-G MC M-G MC M-G MC M-G MC M-G MC M-G MC M-G MC M-G MC 0M-G MC 0M-G MC M-G MC M-G MC M-G MC M-G MC M-G MC M-0G MC M-0G MC M-G 0 0 0 0 0 T G(PF) - - -.7.....0....0.... 5.9.9.9 5..9 5.9 5.9. 5.9 9. 9...0. h 9 9 9 7 5 9 7 9 7 7 5 7 7 5 0 5 5 5 50 50 55 H 9 9 9 0 0 50 0.9.9.9.7.7 5. 5. 5. 5..... 7. 7. 7......0.0.0.0.....0 9. A B L K 5. 5. 5. 5..7.7.7........ 50.0 5. 5. 5... 7.7 7.7 7.7 7.7.....5.5... 5. 5. 5. 7.7 7.7 7.7 7.7 9.0 9.0 9.0... 5....7. 9..9 0..5 7..7.0....0.9.5.0.9.7..9.9.7 0..7.7 5. 5. 7. 9. 5. 55.9..7.70 9.7.9 0..50 7..75.0..5.0...7.9 7.75 5. 57.57 7. 7.. 7.. 7.... 7.......... 5.7... 5.7. 5.7 5.7. 5.7.. 9. 9.. 7... 7........... 5.75..9 0.00 0 9.97 5... 7.59..70 9. 0.9..7. 9.0 9.0 5. 55. 59.9 7..75 0.0 0.0 5. 0.7.0. 7..9.7..5 9. 5. 9. 0..5.. 9.0 5..9 9.0 9.0 5. 50.5 5. 5. 55. 57.5 0. 70. 90..7.0.7.0.9.0.9.0.9.9.00.9 9. 9.00 55.00 A B L K...0..0..0..0....0.0..0.0..0.0..0.0.0.0.0.0 9.0.0 9.0 9.0 9.0 9.0 5.7

ISO Pipe Thread The International Standards Organization created the ISO / and 7/ threads to standardize the nomenclature of several international pipe threads. / The ISO / is a parallel thread that is no sealing threads. The pressure tight seal is usually made metal to metal against the female port or with a gasket. The / is described in following codes.. BS 779 (BSPP). IN-ISO /. JIS B00 (PF). ISO / The / threads sealing available in k-lok ar listed below. A self-centering taper is constructed at the hex. This taper centers a bonded washer to seal to the surface surrounding the female thread. GB Bonded Seal Gasket (Buna N inner ring bonded to carbon steel outer ring) Ordering Number (mm) (in.) (mm) H (in.) (mm) (in.) Sealing by compression against face of body Reference IN 5 Type A GB-- GB-- GB-- GB-- GB-- GB-- GB-0- GB-- 0..7 7.. 7.... 0. 0.5 0. 0.5.0..7.9.0.0.0.5.5.5.5.5 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0.0 0..9.7 5..9 5.05 59. 0. 0. 0.9...9.0. A metal gasket performs the sealing between the reverse bevel of the fitting and the face of the female threaded component. GC Copper Gasket Ordering Number (mm) (in.) (mm) H (in.) (mm) (in.) Sealing by gasket (washer) Reference IN 5 Type B GC-- GC-- GC-- GC-- GC-- GC-- GC-0- GC-- 0 7 7..0 0.9 0.55 0.7 0..0...9.0.0.0.0.0.0.0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 9. 5. 0.7 0..0..50.5.9.0 A gasket is dropped into the flat bottom of the female thread. The face of the male thread exerts a load on the gasket to seal. GG Copper Gasket Ordering Number (mm) (in.) (mm) H (in.) (mm) (in.) GG-- 7. 0.0. 0.07 0.7 0. Sealing by gasket. Reference IN 5 Type Y GG-- GG--. 9. 0. 0...5 0.09 0.0. 7. 0.5 0.70 Gasket Temperature Ratings Gasket Material Ratings GB Buna N -0 C to C (-0 F to 0 F) FKM - C to 0 C (-0 F to 00 F) GC, GG Copper -9 C to 0 C (- F to 00 F)

7/ The ISO 7/ is a tapered thread that is sealing threads working by interference fit. This still requires thread sealant for pressure-tight seal by filling the voids between threads further this prevents galling on piping threads. The sealant usually contains a lubricant. The 7/ is described in following codes.. BS (BSPT). JIS B00 (PT). ISO 7/. IN 999 (male thread only) The 7/ looks similar to the NPT thread. See how different they are as illustrated below. ISO 7/ tapered pipe thread NPT tapered pipe threads *55 thread angle *Pitch measured in millimeters *Truncation of root and crest ar round *Taper angle 7 *0 thread angle *Pitch measured in Inches *Truncation of root and crest are flat *Taper angle 7 ISO Internal Parallel Pipe Thread k-lok Pipe Thread esignator ISO Female Parallel Pipe Size Minimum Full Thread epth L 0. 0.7 0.7 0.55 0. 0.7 Thread Minor iameter 0.7 / 0. 0.50 / 0. 0.5 / 0.0 0.7 / 0.755 0.99 / 0.97.9 /. Minimum Flat iameter for GB & GC C 0.59 0.75 0.9.0.0.57 Male Connector for Metal Gasket OM Connects fractional tube to female ISO parallel thread OM -G OM -G OM -G OM -G OM -G OM -G OM -G OM -G OM -G OM -G OM -G OM -G OM -G OM -G OM -G OM -G OM -G OM 0-0G OM -G T h H (PF) in mm in mm in mm - -.7.7.7 9.05 9.05.75.0 - -........ 7. 7. 7. 0..9 5.7.9.5 7..0 9/ 9/ -/ -/ / -/ -/ -5/ - - -. 9.05.. 9.05..9 9.05..9 0...9.9..9.7 50.0 57.5 7/ 7/ 7/ 9/ 9/ 9/ 9/ / / / - - - - - -....... 7. 7. 7.....5.5.0.0 7. 57.5 A B L K 5. 5. 5. 5..7.7.7........ 50.0 5. 5. 5. 7.7 7.7 7.7 7.7 9.0 9.0 9.0... 5..7.70 9.7.9 0..50 7..75.0..5.0...7.9 7.75 5. 57.57 7... 7........... 5.75..9 0.00 0 9.97 5... 7.59..70 9. 0.9..7. 9.0 9.0 5. 55. 59.9 7..75.7.0.7.0.9.0.9.0.9.9.00.9 9. 9.00 55.00

Male Connector for Metal Gasket OM Connects metric tube to female ISO parallel thread OM M-G OM M-G OM M-G OM M-G OM M-G OM M-G OM M-G OM M-G OM M-G OM M-G OM M-G OM 0M-G OM 0M-G OM 0M-G OM M-G OM M-G OM M-G OM M-G OM 5M-G OM M-G OM M-G OM M-G OM M-G OM 0M-G OM 0M-G OM M-G OM M-G OM M-G OM M-G OM M-G OM M-0G OM M-0G OM M-G 0 0 0 5 0 0 T G(PF) - - -....0....0... 5.9 5.9.9.9.9 5..9 5.9 5.9. 5.9 9. 9.... h H 9 9 7 5 9 7 9 7 7 5 7 7 7 5 0 5 5 5 50 50 55 9 9 9 0 0 50 0 A B.9.9.7 5. 5. 5. 5..... 7. 7. 7......0.0.0.0.....0 9. 5. 5.. 7.7 7.7 7.7 7.7.....5.5.....7..9 0..5 7..7.0....0.9.5.0.9.7.9..9.9.7 0..7.7 5. 5. 7. 9. 5. 55.9.7 7.. 7. 7.... 7.......... 5.7.... 5.7. 5.7 5.7. 5.7.. 9. 9. 0. 0.0 5. 0.7. 7..9.7..5 9. 5. 9. 0..5.. 9.0 5. 9.0.9 9.0 9.0 5. 50.5 5. 5. 55. 57.5 0. 70. 9...0...0..0....0.0..0.0..0.0.0..0.0.0.0.0.0 9.0.0 9.0 9.0 9.0 9.0 5.7 Vent Protector M M-N M-N M-N M-N T (NPT) H in mm 7. 9/ 5.7 0.0 / 7...00 -/.9 Bore-thru pipe plug with Stainless Steel 0x0 mesh, 0.00 diameter wire screen. K-LOK vent protector, known as the mud dauber fittings, protects open ends of instruments, tubing, outlet vents by preventing foreign materials such as insects, debris from entering and clogging systems. Standard S Stainless steel and Brass meterials. L 0.57 0.57.9.70 L.. 9.05 9.05

Bulkhead Male Connector MCB Connects fractional tube to female NPT thread T h h H A L L in mm (NPT) in mm in mm in mm MCB -N MCB -N MCB -N MCB -N MCB -N MCB -N MCB -N MCB -N MCB -N MCB -N MCB 0-0N MCB -N MCB -N - -.7 9.05.75.0 50.0 - -... 7. 7. 7. 9.9 0. 5.7.5 7..0 5.97 5/ 5/ -/ - - - - 5.7 5.7 9.05 9.05... 0.. 7. 57.5 5/ 5/ -/ - - - - 5.7 5.7 9.05 9.05 9.05.. 0.. 7. 57.5 7/ 9/ 9/ / / / - - - -... 7. 7. 7....5.0 7. 57.5 7.0 5. 5..7.7.7..... 50.0 7.5 9.7. 5.97 50.0 50.0 5. 5.0 5.7.0.0 5.97 9.0 0... 9. 9. 9..75.75 7. 5. 7.75 9.7 5.. 5. 57.0 57.0.75.. 7.0 9. 0.07 0....5.5....9.9 57.0 7.5 9.7 Panel Hole rill size..50.50... 9. 9..7.7.7 9..7 Panel Max Thickness 0. 0..7.7.7.7 9.05 9.05 9.05 9.05 5 Male lbow LBM Connects fractional tube to female NPT thread LBM -N LBM -N LBM -N LBM -N LBM -N LBM -N LBM -N LBM -N LBM -N T h H A B L L in mm (NPT) in mm in mm 9.05... 7. 7. 0. 5.7.5 / / / - - 5.7 5.7 0. 0. 0..5.9 9/ 9/ / / / - -.. 7. 7. 7....5.0 5. 5..7.7.7.... 7.7 7.7 9.0 9.0 9.0. 7.7 7.7 0.57 0.57.7.9.. 9..00.00.0 0..5.0.....95 0.9 7.

Male lbow LM Connects fractional tube to female NPT thread LM -N LM -N LM -N LM -N LM -N LM -N LM -N LM -N LM -N LM -N LM -N LM 5-N LM 5-N LM 5-N LM -N LM -N LM -N LM -N LM -N LM -N LM -N LM -N LM -N LM 0-N LM 0-N LM 0-N LM -N LM -N LM -N LM -N LM -N LM 0-0N LM -N LM -N T h H in mm (NPT) in mm in mm A B L L /.59 /.7 7/. 5/. 0.9 5. 9.05 7.7 /.59.7 7/. 5/. 0.9 5. 9.05 7.7.7. 7/. 5..0.9.90.7. 7/. 5..0.9. /.7.0.7.00.79.79 /.7.0.7.00.79. /.0 9/. 5. 7.7 5.90.79. 9/. 5. 7.7 5.7.79. 9/. 5. 7.7 9. 7..7. / 7. 9/. 5. 7.7.5 9.7.0. / 0. 9/. 5. 7.7.0.97.0 5/. 9/. 5.7..5..70 9. 5/ 9/. 5.7..5. 9.77.50 5/ / 7. 5.7..5. 0..0. 5.7 / 7..7 9.0. 0. 0.0 7. 5.7 / 7..7 9.0. 0. 7. / 7. / 7..7 9.0.7..0 7. / 0. / 7..7 9.0.90..0 7. -/.9 / 7..7 9.0 9.7 7.0. 7. / 0....90.0.0 / 0....90.0.0 0. / 0....90.0.0 0. -/.9.. 9.7 9.7. 5.7 5/...00 7.0 0. 5.7.9 5/...00 7.0 5.0 5.7 -/.9. 9.7 9.7. 9.05.9 -/.9 -.57. 9.7 9.7 7.00 9.05 5.7 -/.9 -.57. 9.7 9.7.. 5.7 -.9 -.75.90.5.70.5 5.7 -.9 -.0... 9.0.0.5 -.9 -.0... 9.0.70 -.75-7. -/. - 7....50.5 7.75 -.0 -.0 50.0-57.5 50.0 5. 50.0 77 0.5 50.0 5.97-7.0.7.7 9.0 07. 70.

Male lbow LM Connects metric tube to female ISO tapered thread LM M - R LM M - R LM M - R LM M - R LM M - R LM M - R LM M - R LM M - R LM M - R LM M - R LM M - R LM M - R LM 0M - R LM 0M - R LM 0M - R LM 0M - R LM M - R LM M - R LM M - R LM M - R LM M - R LM M - R LM M - R LM M - R LM M - R LM M - R LM 0M - R LM 0M - R LM M - R LM M - R LM M - R LM M - R T R(PT) h H 0 0 0 0 0 0............. 7.. 7..9.7.9 5..9 5.9 5.9. 5.9..7.7.7.7.7.7 7.5 0... 7.5 0. 7.5 7.5 7.5 0. 0. 0. 0. 0. 7.0... 7.0 7.0.9.9.9.9.9.9 9 9 9 9 0 0 A B L L.9.9.7.7 5. 5. 5. 5..... 7. 7. 7. 7.......0.0.0.0.. 5. 5... 7.7 7.7 7.7 7.7.....5.5 7.0.0.. 9. 9.......9.9.9.9.9.9.9.9 9.7 9.7 9.7 9.7.5.5.5.5...... 7.0 7.0 9.... 0...5.5.5.5.0.0.0.0 9..0.0 9. 9. 9..... 9. 9. 7........0 9...0....0....0. 0. 5.....7.7.7.5.7.5

Male Run Tee TRM Connects fractional tube to female NPT thread TRM -N TRM -N TRM -N TRM -N TRM -N TRM -N TRM -N TRM -N TRM -N TRM -N TRM -N TRM 5-N TRM 5-N TRM 5-N TRM -N TRM -N TRM -N TRM -N TRM -N TRM -N TRM -N TRM -N TRM 0-N TRM 0-N TRM 0-N TRM -N TRM -N TRM -N TRM -N TRM -N TRM 0-0N TRM -N TRM -N T (NPT) H in mm in mm in mm A B L L /.59 /.7 7/. 5/. 0.9 5. 9.05 7.7 /.59.7 7/. 5/. 0.9 5. 9.05 7.7.7. 7/. 5..0.9.90.7. 7/. 5..0.9. /.7.0.7.00.79..79 /.7.0.7.00.79. /.0 9/. 5. 7.7 5.90.79. 9/. 5. 7.7 5.9.79. 9/. 5. 7.7 5 7.0.7. / 7. 9/. 5. 7.7.5 9.7.0. / 0. 9/. 5. 7.7.0.97 5.0 5/. 9/. 5.7..5.5 9.7 9. 5/ 9/. 5.7..5.5 9.77.50 5/ / 7. 5.7..5. 0..0 7. 5.7 / 7..7 9.0. 0. 7. / 7. / 7..7 9.0.7.. 7. / 0. / 7..7 9.0.90.7.0 7. -/.9 / 7..7 9.0 9.7 7.0. 7. / 0....90.0.0 / 0....90.0.0 0. / 0....90.0.0 0. -/.9.. 9.7 9.. 5.7 5/.. 0.0 9.0 5.7.9 5/.. 0.0.00 5.7 -/.9. 9.7 9.7. 9.05.9 -/.9 -.5. 9.7 9.7 7.00 9.05 5.7 -/.9 -.5. 9.7 9... 5.7 -.9 -.75.90.5.70.5 5.7 -.9 -.0... 9.0.0.5 -.9 -.0... 9.0.70 -.75-7. -/. - 7....50.5 7.75 -.0 -.0 50.0-57.5 50.0 5. 50.0 77 0.5 50.0 5.97-7.0 7.5.7 9.0 07. 70.

Male Run Tee TRM Connects metric tube to female ISO tapered thread TRM M-R TRM M-R TRM M-R TRM M-R TRM M-R TRM M-R TRM M-R TRM M-R TRM M-R TRM M-R TRM M-R TRM M-R TRM 0M-R TRM 0M-R TRM 0M-R TRM 0M-R TRM M-R TRM M-R TRM M-R TRM M-R TRM M-R TRM M-R TRM M-R TRM M-R TRM M-R TRM M-R TRM 0M-R TRM 0M-R TRM M-R TRM M-R TRM M-R TRM M-R T R(PT) h H 0 0 0 0 0 0............. 7.. 7..9.7.9 5..9 5.9 5.9. 5.9..7.7.7.7.7. 7.5 0... 7.5 0. 7.5 7.5 7.5 0. 0. 0. 0. 0. 7.0.. 7.0 7.0 7.0.9.9.9.9.9.9 9 9 9 9 0 0 A B L L.9.9.7.7 5. 5. 5. 5..... 7. 7. 7. 7.......0.0.0.0.. 5. 5... 7.7 7.7 7.7 7.7.....5.5 7.0.0.. 9. 9.......9.9.9.9.9.9.9.9 9.7 9.7 9.7 9.7.5.5.5.5...... 7.0 7.0 9.... 0...5.5.5.5.0.0.0.0 9..0.0 9. 9. 9..... 9. 9. 7........0 9...0....0....0. 0. 5.....7.7.7.5.7.5

Male Branch Tee TBM Connects fractional tube to female NPT thread TBM -N TBM -N TBM -N TBM -N TBM -N TBM -N TBM -N TBM -N TBM -N TBM -N TBM -N TBM 5-N TBM 5-N TBM 5-N TBM -N TBM -N TBM -N TBM -N TBM -N TBM -N TBM -N TBM -N TBM 0-N TBM 0-N TBM 0-N TBM -N TBM -N TBM -N TBM -N TBM -N TBM 0-0N TBM -N TBM -N T h H A B L L (NPT) in mm in mm in mm / / / / 5/ 5/ 5/ - -.59.59.7.7.7.7 5.7 5.7 5.7 9.05 9.05..75.0 50.0 / / - -.7.7...0.0.0..... 7. 7. 7. 7. 7. 0. 0. 0..9.9 5.7 5.7 5.7.5 7..0 5.97 7/ 7/ / / 9/ 9/ / / / -/ / / / -/ 5/ 5/ -/ -/ -/ - - - -/ -.. 7. 0... 7. 5.7 7. 0..9 0. 0. 0..9...9.9.9.9.9.9. 50.0 5/ 5/ 7/ 7/ 9/ 9/ 9/ 9/ 9/ / / / / - - - - - - -....... 5.7 5.7 5.7 7. 7. 7. 7......5.5.75.0.0 7. 57.5 7.0...7.7 5. 5. 5. 5. 5.....7.7.7.7..........90... 50.0 7.5 0.9 0.9 5. 5..00.00 7.7 7.7 7.7 7.7 7.7.5.5.5 9.0 9.0 9.0 9.0... 5..7 5. 5..0.0.79.79 5 5 5.5.0.5.5...7.90 9.7.90.90.90 9.7 0 0 9.7 9.7 9.7.5...50 50.0 9.0 9.05 9.05.9.9..90.9 7.0 9.7.97 9.7 9.77 0. 0...7 7.0.0.0.0 9.7.0.0 9.7 9.7 9.7.70 9.0 9.0.5 77 07. 7.7 7.7.90..79..79 9.0.7.0 5.0 9..50.0..0..0.0.0. 9.0.00. 7.00..5.0.70 7.75 0.5 70.

Male Branch Tee TBM Connects metric tube to female ISO tapered thread TBM M - R TBM M - R TBM M - R TBM M - R TBM M - R TBM M - R TBM M - R TBM M - R TBM M - R TBM M - R TBM M - R TBM M - R TBM 0M - R TBM 0M - R TBM 0M - R TBM 0M - R TBM M - R TBM M - R TBM M - R TBM M - R TBM M - R TBM M - R TBM M - R TBM M - R TBM M - R TBM M - R TBM 0M - R TBM 0M - R TBM M - R TBM M - R TBM M - R TBM M - R T R(PT) h H 0 0 0 0 0 0............. 7.. 7..9.7.9 5..9 5.9 5.9. 5.9..7.7.7.7.7. 7.5 0... 7.5 0. 7.5 7.5 7.5 0. 0. 0. 0. 0. 7.0.. 7.0 7.0 7.0.9.9.9.9.9.9 9 9 9 9 0 0 A B L L.9.9.7.7 5. 5. 5. 5..... 7. 7. 7. 7.......0.0.0.0.. 5. 5... 7.7 7.7 7.7 7.7.....5.5 7.0.0.. 9. 9.......9.9.9.9.9.9.9.9 9.7 9.7 9.7 9.7.5.5.5.5...... 7.0 7.0 9.... 0...5.5.5.5.0.0.0.0 9..0.0 9. 9. 9..... 9. 9. 7........0 9...0....0....0. 0. 5.....7.7.7.5.7.5

Female Connector CF Connects fractional tube to male NPT thread CF -N CF -N CF -N CF -N CF -N CF -N CF -N CF -N CF -N CF 5-N CF 5-N CF -N CF -N CF -N CF -N CF -N CF -N CF -N CF -N CF -N CF 0-N CF 0-N CF 0-N CF -N CF -N CF -N CF -N CF -N CF 0-0N CF -N CF -N T h H A B L (NPT) in mm in mm in mm / / / 5/ 5/ - -.59.59.7.7.7 5.7 5.7 5.7 9.05 9.05..75.0 50.0 / - -.7.7...0.... 7. 7. 7. 7. 7. 0. 0. 0. 0. 5.7 5.7..5.5 7..0 5.97 7/ 9/ 9/ 9/ 9/ -/ 9/ -/ -5/ -/ -/ -5/ 5/ -/ -5/ -/ -5/ -5/ - - - - -... 9.05.. 9.05..9. 9.05 5.7 9.05..9. 0...9...9..9...9.7 5.9 0. 7.0 5/ 5/ 7/ 7/ 9/ 9/ 9/ 9/ / / / / / - - - - - - -...... 5.7 5.7 7. 7. 7. 7. 7......5.5.75.0.0 7. 57.5 7.0...7 5. 5. 5. 5....7.7.7.7.7..........90... 50.0 7.5 0.9 0.9 5. 5..00 7.7 7.7 7.7 7.7.5.5 9.0 9.0 9.0 9.0 9.0... 5..7 9. 0.57 9.9..7. 0. 5.05. 9. 0..75.57 0. 0..75.57.0.75.57.0.57.0 9.. 50.0 5.57 5.....70.5 9.7. 5. 7.59..00..7 7.59 9..9 7.75 0..9.7..9.7..7. 9.7 5.. 7.7. 0.0

Female Connector CF Connects metric tube to male ISO tatered thread T R(PT) h H CF M-R. CF M-R. 9 CF M-R. CF M-R. CF M-R. 9 CF M-R. CF M-R. 7 CF M-R. 5 CF M-R. 9 CF M-R. CF M-R. 7 CF 0M-R 0 9 CF 0M-R 0 9 9 CF 0M-R 0 9 CF 0M-R 0 7 9 CF M-R. CF M-R CF M-R CF M-R 7 CF M-R 5 CF 5M-R 5.9 7 CF M-R.7 7 CF 0M-R 0 5.9 0 CF 0M-R 0 5.9 5 CF M-R. 5 CF M-R. CF M-R. 5 CF M-R. A B L.9 5...7.9 5..9.5.7.. 9.7 5. 7.7.9. 5. 7.7. 5. 5. 7.7.9 5. 7.7 5..5...... 7.0.. 0. 7.7.. 5.. 7...0 7. 0. 7. 7..0. 7......5. 0..0..0....7..9 9.0..7..9.0 7..0 9. 9.7.0 9. 9.7.0 7. 5..5. 5...5 50.0.

Gauge Connector CG Seepage for GG gasket Connects metric tube to ISO parallel thread (gauge) T R(PF) h H CG M-G. 9 CG M-G. 9 CG M-G. CG M-G. 7 CG M-G 5.5 9 CG M-G.5 CG M-G 7.0 7 CG 0M-G 0 5.5 9 9 CG 0M-G 0.5 9 CG 0M-G 0 7.0 7 9 CG M-G 5.5 CG M-G.5 CG M-G 7.0 7 CG 0M-G 0 7.0 0 CG M-G 7.0 0 Connects fractional tube to ISO parallel thread (gauge) CG -G CG -G CG -G CG -G CG 5-G CG 5-G CG -G CG -G CG -G CG -G CG -G CG -G A B L T h H in mm G(PF) in mm in mm A B L. 9/. 9/. 5. 7.7.0.00.55. 9.05 9/. 5. 7.7 0..00 7.59. 5/. 9/. 5. 7.7 0.. 7.59. -/.9 9/. 5. 7.7 0.07.0. 5/ 5.5 9.05 5.7..5 0.9.00.5 5/ 7. -/.9 5.7..5.0.0 0. 5.5 9.05 / 7..7 9.0.75.95 9..0 5/. / 7..7 9.0... 7. -/.9 / 7..7 9.0.5.0.9 5.50....0.00.95.0 5/....9..5 7. -/.9...0.0..9 5. 5. 5.... 7. 7. 7.....0.0 5. 7.7 7.7 7.7....7 0. 0...0.7.0........ 9 9 9 9 9 9 5. 7. 7..0.5. 0.5 9....9.. 5. 5. Bulkhead Female Connector CBF Connects fractional tube to male NPT thread T h h H in mm (NPT) in mm in mm in mm CBF -N.7. 9/. 7/. CBF -N. 5.7 5.7 9/. CBF -N. 9.05 5.7 9/. CBF -N 7. 9.05 9.05 / 7. CBF -N 7.. 9.05 / 7. CBF -N 0. 5/. 5/.. CBF -N 0. -/.9 5/.. CBF -N 9.05 5.7 -.75 -/ 0. -.57 CBF -N.5 -.7 -.7 -.0 CBF 0-0N -.75-7. - 7. - 7. - 7. CBF -N -.0 -.0-57.5-57.5-57.5 CBF -N 50.0 5.97 - - 7.0 Connects metric tube to male NPT thread CBF M-M CBF M-M CBF M-M CBF M-M T (NPT) h h H... 5. 9.0 9.0 7.0 5..0 7..0 5. 5... 9...7 5. A A 5. 5..7.7..... 50.0 7.5.0 9..5 7.75 9. 5.5 5..0.0.9 95.0.... L L..70..99. 5. 9. 55. 9. 5.77.75.7.75.5.0 7.5 5. 9. 7.75 05.59 9.7.57 5.. L L.90 5.0 5.5.50 5.00.0 5.55.90..5.5...9.9 7. 57.0 7.5 9.7 Panel Hole rill Size..50.50.. 9. 9..79.7.7 9. 5 Panel Hole rill Size.5.5. Panel Max Thickness 0. 0..7.7.7 9.05 9.05 9.05 9.05 Panel Max Thickness 0. 0...7

Female lbow LF Connects fractional tube to male NPT thread LF -N LF -N LF -N LF -N LF -N LF -N LF -N LF 5-N LF 5-N LF -N LF -N LF -N LF -N LF -N LF -N LF -N LF 0-N LF 0-N LF -N LF -N LF -N LF -N LF -N LF M-N LF M-N LF M-N LF M-N LF M-N LF M-N LF M-N LF 0M-N LF 0M-N LF 0M-N LF 0M-N LF M-N LF M-N LF M-N LF M-N / 5/ 5/ 0 0 0 0.7.7.7 5.7 5.7 9.05 9.05....0.... 7. 7. 7. 7. 0. 0. 0. 5.7 5.7..5.5........7 / / / 9/ / / / / / 5/ -/ - - - -/ Connects metric tube to male NPT thread T h H A B L L (NPT) in mm in mm in mm 7. 0. 5.7 7. 7. 7. 0. 0. 0..9 7. 7. 0.. 7. 5.7 7. 0. 0. 0...9.9.9.9. T (NPT) h H 9 9 9 9 7/ 7/ 9/ 9/ 9/ 9/ / / / / - - - - - 5. 5. 5. 5.... 7. 7. 7. 7.......... 5.7 5.7 7. 7. 7. 7.....5.5.75.0.0.7 5. 5. 5. 5....7.7.7.7........90.. 7.7 7.7 7.7 7.7... 5. 5..00 7.7 7.7 7.7 7.7.5.5 9.0 9.0 9.0 9.0.. 9.. 7....0.9.9.9.7.9.9.7 9.7.0 0..79 5.5. 7.7....7.90.70.90.90.70 9.7 9.7.5.5..0 7.0 9..7. 9.9 0. 5..5.5.5..0... 7..9 9.7.75.5.70 0. 0...7.0.0.0..0 9.7 9.7.70.70 9.0 50.9 9.05.5 9.05 9.05.5.5. 9.05.5 9.05.5.5..5.5..5...75.75.75.0 A B L L 9.00.0.0.0 9.00.0.0 9.00.5.0.0.0.5.0.0

Female Run Tee TRF Connects fractional tube to male NPT thread TRF -N TRF -N TRF -N TRF -N TRF -N TRF -N TRF -N TRF 5-N TRF 5-N TRF -N TRF -N TRF -N TRF -N TRF -N TRF -N TRF -N TRF 0-N TRF 0-N TRF -N TRF -N TRF -N TRF -N TRF -N T h H A B L L (NPT) in mm in mm in mm / 5/ 5/.7.7.7 5.7 5.7 9.05 9.05....0.... 7. 7. 7. 0. 0. 0. 5.7 5.7..5.5 / / / 9/ / / / / / 5/ -/ - - - -/ 7. 7. 0.. 7. 5.7 7. 0. 0. 0...9.9.9.9. 7/ 7/ 9/ 9/ 9/ 9/ / / / / - - - - -...... 5.7 5.7 7. 7. 7. 7.....5.5.75.0.0.7 5. 5. 5. 5....7.7.7.7........75.0.0 5. 5..00 7.7 7.7 7.7 7.7.5.5 9.0 9.0 9.0 9.0...0 0..79 5.. 7.7....7.90.70.90.90 9.7.70 9.7.5.5..0. 7..9 9.7.75.5.70 0. 0...7.0.0.0 9.7.0. 9.7.70.70 9.0 50.9 9.05.5 9.05 9.05.5.5. 9.05.5 9.05.5.5..5.5..5...75.75.75.0 Connects metric tube to male NPT thread TRF M-N TRF M-N TRF M-N TRF M-N TRF M-N TRF M-N TRF M-N TRF M-N TRF 0M-N TRF 0M-N TRF 0M-N TRF 0M-N TRF M-N TRF M-N TRF M-N TRF M-N T (NPT) h H 0 0 0 0.........7 7. 0. 5.7 7. 0. 0. 0. 0. 0. 0. 9 9 9 9 A B L L 5. 5. 5. 5..... 7. 7. 7. 7.... 7.7 7.7 7.7 7.7.... 9.. 7.....0.9.9.9..9.9 9.7 9.7 7.0 9..7.5 9.9 0.. 5..5....0.0 0.0 0.0 9.00.0.0.0 9.00.0.0.0 9.00.0.0.0.0.0.0.0

Female Branch Tee TBF Connects fractional tube to male NPT thread TBF -N TBF -N TBF -N TBF -N TBF -N TBF -N TBF -N TBF 5-N TBF 5-N TBF -N TBF -N TBF -N TBF -N TBF -N TBF -N TBF -N TBF 0-N TBF 0-N TBF -N TBF -N TBF -N TBF -N TBF -N T h H A B L L (NPT) in mm in mm in mm / 5/ 5/.7.7.7 5.7 5.7 9.05 9.05....0.... 7. 7. 7. 0. 0. 0. 5.7 5.7..5.5 / / / 9/ / / / / / 5/ -/ - - - -/ 7. 7. 0.. 7. 5.7 7. 0. 0. 0...9.9.9.9. 7/ 7/ 9/ 9/ 9/ 9/ / / / / - - - - -...... 5.7 5.7 7. 7. 7. 7.....5.5.75.0.0.7 5. 5. 5. 5....7.7.7.7........90.. 5. 5..00 7.7 7.7 7.7 7.7.5.5 9.0 9.0 9.0 9.0...0 0..79 5.5. 7.7....7.90.70.90.90 9.7.70 9.7.5.5..0. 7..9 9.7.75.5.70 0. 0...7.0.0.0 9.7.0. 9.7.70.70 9.0 5.59 9.05.5 9.05 9.05.5.5. 9.05.5 9.05.5.5..5.5..5...75.75.75.0 Connects metric tube to male NPT thread TBF M-N TBF M-N TBF M-N TBF M-N TBF M-N TBF M-N TBF M-N TBF M-N TBF 0M-N TBF 0M-N TBF 0M-N TBF 0M-N TBF M-N TBF M-N TBF M-N TBF M-N T (NPT) h H 0 0 0 0.........7 7. 0. 5.7 7. 0. 7.50 0. 0. 0. 0. 9 9 9 9 A B L L 5. 5. 5. 5..... 7. 7. 7. 7.... 7.7 7.7 7.7 7.7.... 9.. 7.....0.9.9.9..9.9 9.7 9.7 7.0 9..7.5 9.9 0.. 5..5.5.5..0.0 0.0 0.0 9.00.0.0.0 9.00.0.0.0 9.00.0.0.0.0.0.0.70

Reducer R Connects fractional tube to frational k-lok R - R - R - R - R - R - R - R - R - R - R - R - R - R -5 R - R - R -0 R - R 5- R 5- R - R - R - R -0 R - R - R - R - R -0 R - R - R0- R0- R0- R- R- R-0 R- R- R0- R0- R- port h in mm in mm in mm in mm / / / / 5/ 5/ - - -.59.59.7.7.7.7.7.7.7.7 5.7 5.7 5.7 9.05 9.05.75.75.0 / / / 5/ - - -.7.59.7.7.7.7.7 5.7 9.05 5.7 9.05 5.7 9.05 9.05..75.0 50.0.0 50.0 50.0.7.7.7.0.....0.0.0.0....... 7. 7. 7. 7.. 7. 9.90 0. 0. 0. 9.90 5.7.5.5.5 7. 7..0 5/ 5/ 7/ 7/ 7/ 7/ 7/ 9/ 7/ 7/ 9/ / / 9/ 9/ / / / / / / / -/ 5/ 5/ -/ -/ -/ - - - - - -......... 7. 0... 5.7 5.7 5.7 7. 0. 0. 0. 0. 0. 0..9...9.9.9.9. 5.9 7. 7. 57.5 5/ 5/ 7/ 7/ 7/ 7/ 7/ 7/ 9/ 9/ 9/ 9/ 9/ 9/ 9/ 9/ / / / / / - - - - - - - -.............. 5.7 5.7 7. 7. 7. 7. 7........57.57.0.0.0 57.5 7.0 7.0 H A B L...7.7 5. 5. 5. 5. 5. 5. 5. 5....7.7.7.7.7................ 50.0 0.9 0.9 5. 5. 5. 5. 5. 5..00.00 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.7.5.5 9.0 9.0 9.0 9.0 9.0..... 5. 7..5.9 7. 9. 0.9 7.59.9 0. 9. 0..75.5.7. 0. 0..5 0..0 5...9.9.79.57... 50.0.5 5.97 50.0.5 5.. 00..0 0. 0. 9..9.95.5.9.0 7.59.9.79 7.0. 7.59 9. 9.7 0...00 7.75.9.0..5 50.9 50.9.95.7 5. 5. 5. 0.9 5. 5. 0.9 5.. 0.5.5 0. 5..

Reducer R Connects metric tube to fractional k-lok port R M- R M- R M- R M- R M- R M- R M-5 R M- R M- R M- R M- R 0M- R 0M- R M- R M- R M- R M- R M- 0 0 in 5/ mm.7.7. 9.05 9.05.7.0...0...... 7. 5. 5. 0. h H 5 5 7 7 5 9 9 0 0 A B L.9.9.9.7 5. 5. 5. 5. 5... 7. 7.... 5. 5. 5.. 7.7 7.7 7.7 7.7 7.7...5.9.9 0.5..5..9.5 0.....7.0 5. 57..5.5. 7..9 9. 9.9 0.7..0 7.. 9. 5. 5. 5.. Connects metric tube to metric k-lok R M-M R M-M R M-M R M-0M R M-M R M-M R M-M R M-0M R M-M R M-M R M-0M R M-M R 0M-M R 0M-M R 0M-5M R 0M-M R M-M R M-0M R M-M R M-M R M-0M R M-M R M-M R M-M R M-M R M-M R M-0M R M-M R M-M R 0M-M R 0M-M R 0M-M R 0M-M R M-M R M-0M R M-M R M-M R M-0M 0 0 0 0 0 0 0 0 0 0 0 5 0 0 0 0 0 port h H.7......... 5. 5. 5. 9 9 9 9 9. 7.7 7 9. 9. 7 0.7 7 0 5. 7 0 5. 7 0 5. 7 0.7 0.9 0 5. 0 5. 0.9 0 5. 0. 0.9 5 5. 5 A B L.9.9.9.9.7 5. 5. 5. 5.... 7. 7. 7. 7.........0.0.0.0.0.0.0.. 5. 5. 5. 5.. 7.7 7.7 7.7 7.7....5.5.9.. 0.5.5..9..5 0....7.7...7.7.0.0 5..9.5.0 7.5 7.5 5. 7. 7. 9. 5. 7. 9. 5. 50. 5. 5. 5.0.. 7..9 9.9 0.7. 0..0 7.. 9. 5. 5..9.7 5. 5. 5. 5.. 5.0 5. 5. 57. 57.. 5 5 59.. 5 59....

Bulkhead Adapter AB Bulkhead Adapter Male lbow The bulkhead adapter is useful for panel construction when you need to set a direction. Connects fractional tube to fractional k-lok AB - AB - AB - AB - AB0-0 AB- AB0-0 AB- AB- port h H in mm in mm in mm.7.0 7/.. 5.7 9/. 7. 9.05 / 7. 0. 5/.. 5.7 -/.9 0. -. -.0 -.75 7. - 7. - 7. -.0.0-57.5-57.5 50.0 5.97-7.0 A 5..7.... 50.0 7.5 Set a direction.9.5 5..7 5.0. 0.07..79 L L.. 9..75.5 5. 7.75 9.7 5..5 5.7 7.50..70.70 0.00 5.50.0 55.. 75. 00..7 5.5 5...5..9.7 57.0 7.5 9.7 Panel Hole rill Size..50. 9...7.7 9. 5 Panel Max Thickness 0..7 9.05 9.05 9.05 9.05 Male Adapter AM Connects metric k-lok port to female ISO tapered thread T R(PT) h L AM M-R AM M-R AM M-R AM M-R AM 0M-R AM 0M-R AM 0M-R AM M-R AM M-R AM M-R AM M-R AM M-R AM M-R AM M-0R AM M-0R AM M-R 0 0 0 - - -.0... 7.7 7.7.9 7. 9..9.9 5.9.. 7...... 7.7 7.7 7.7 9. 9. 9..9.9 - - - - 7 7 7 5 55.5 5.75 5.75.50 7.50 7.50 7.50.50.50.50.90.90.70.70 0.00 5.50 9... 9. 9.9 0. 5..5.5 5. 5. 5. 7.7 7..0 9.

Male Adapter AM k-lok Adapter eliminates alignment problems Female Pipe Port In the derection shown the female port is required to connect with tubing. Connects fractional k-lok port to female NPT thread T h (NPT) in mm in mm AM -N.7.57.77 7/. AM -N.7 7..77 9/. AM -N /.7.57.0 7/. AM -N /.7 7..0 9/. AM -N.57.57 7/. AM -N 7..57 9/. AM -N 0..57 / 7. AM -N.57. AM 5-N 5/.57 7/. AM 5-N 5/ 7. 9/. AM -N.57 7. 7/. AM -N 7. 7. 9/. AM -N 0. 7. / 7. AM -N 7.. AM -N 7. 9.90 9/. AM -N 0. 9.90 / 7. AM -N 9.90. AM 0-N 5.7 0. / 7. AM 0-N 5.7. AM 0-N 5.7. -/.9 AM -N 9.05.9. AM -N 9.05..9 -/.9 AM -N 9.05.5.9 -.9 AM -N.. 7.7 -/.9 AM -N. 0.0 -/.9 AM -N.5 0.0 -.9 AM 0-0N -.75-7. - -.5 AM -N -.0 -.7 - - 5.9 AM -N 50.0.5 - -.5.5.0.0 5.75 5.75 5.75 5.75.0.0 7.50 7.50 7.50 7.50.0.0.0.70.70.70.70.70.70.70.70.70 0.00 5.50.0 L 0.0 0. 5.5.0 7.0 7...7.0.50.90 9.0 5.0.50 5.0 50.50 7.0 5.0 5.0 5.0 5.0 5 5.0 5.70.00 0. 9. 9. Male lbow L The male elbow is positioning in the wrong direction. Male Adapter To eliminate the problem, use a male adapter into the female port. Union lbow Male Adapter Connect a union elbow to the adapter by tightening the k-lok port with a wrench while holding the elbow wrench pad in the desired direction.

Female Adapter AF Connects fractional k-lok AF -N AF -N AF -N AF -N AF -N AF -N AF -N AF -N AF 5-N AF 5-N AF -N AF -N AF -N AF -N AF -N AF -N AF -N AF 0-N AF 0-N AF 0-N AF -N AF -N AF -N AF -N AF -N AF -N AF 0-0N AF -N AF -N port to male NPT thread T h in mm (NPT) in mm / / 5/ 5/ - -.7.7.7.7 5.7 5.7 5.7 9.05 9.05 9.05..75.0 50.0 - -.77.77.0.0.57.57.57.57 7. 7. 7. 7. 9.90 9.90 9.90.9.9.9 7.7 0.0 0.0 7..7.5 9/ 9/ 9/ -/ 9/ 9/ -/ -/ -/ -5/ -/ -5/ - -5/ -5/ - - - -. 9.05. 9.05. 9.05..9. 9.05. 9.05..9 9.05..9..9..9..7...7 5.9 0. 7.0.5.5.0.0 5.75 5.75 5.75 5.75.0.0 7.50 7.50 7.50 7.50.0.0.0.70.70.70.70.70.70.70.70.70 0.00 5.50.0 L.50 5.0.00 5..0 7.0 9.7 5.50.9 7.59.9.0 0..7. 5. 5.0. 5. 55.7 5. 5. 5. 57.5 0.70. 77.7.90 07. Connects metric k-lok port to male ISO tapered AF M-R AF M-R AF M-R AF M-R AF 0M-R AF 0M-R AF 0M-R AF M-R AF M-R AF M-R AF M-R 0 0 0 T R(PT).... 7.7 7.7 7.7 9. 9. 9..9 h 9 9 9 7 9 7.5 5.75 5.75.50 7.50 7.50 7.50.50.50.50.90 L.5.50 7.0 7.0.0 0.0.50.70.00 5.0 5.0

Port Connector CP Installation Instructions... Port Port k-lok port connector facilitates close connection to another port.. Remove the nut and ferrules from k-lok port and set nut only (no ferrules) over the port connector. Tighten the nut with wrench until sharp rise in torque is felt. Insert the other end of port connector into port and tighten nut - turns with wrench. for ", mm only turn from finger tight. Connects two fractional k-lok CP- CP- CP- CP-5 CP- CP- CP- CP- Connects two metric k-lok CP-M CP-M CP-M CP-M CP-0M CP-M CP-5M CP-M CP-M CP-0M CP-M CP-M CP-M CP-M CP-M in mm /.59.7 5/ 9.05 0 5 0.00.77.57 7. 9.90.9 0.0..... 9..7.7.9 5. 9.. 7...0.09 9.9 0.9 5.7 9..0 7.0 9.0.0. 5.0 9.0 9.0.0.0.97.0. 7. 0. 5.75.79 0.0 0..90 7..5 ports 5.70.7.70 0.00 0.0.00 7.7 7.0 9.0 9.0.50.0 5.0.0 ports L.7.5.90. 5. 7..00 L.0..0.90.0 5.0 7.0 7.0 7.0.90 9.0.00.50 9.70.90 Reducing Port Connector CRP Connects two fractional k-lok CRP - CRP - CRP - CRP - CRP - CRP - CRP - CRP - CRP - ports in mm in mm.7 /.59.7.7 9.05 9.05.00.... 7. 9.90 9.90.9.0 9.9 5.7 5.7 9.0.0..5.5 5.75 5.75 7.7.0 7.90.0.0..0..0...0 L 7.7.0..9 9. 0. 7.5.7. Connects two metric k-lok ports CRP M-M CRP M-M CRP 0M-M CRP 0M-M CRP M-M CRP M-M CRP M-0M CRP M-M CRP M-M CRP M-M CRP M-M CRP M-M 0 0 0...... 7.7. 9. 9. 9. 9. 9.0.0.. 5.0 5.0 5.0 9.0 9.0. 7..50 5.70 5.70.0 5.70.0 7.50 5.75.0.00.00.00.......... 9.9. L.0.70.00.00 9.0 9.0 0.0 0.0.0 5.50 0.0 5.0

AN Union UA Connects fractional tube to AN flared tube UA - UA - UA - UA - UA 5-5 UA - UA - UA - UA - UA - UA 0-0 UA - UA - AN Tube Straight Flare Size Thread h H in mm in mm T(U) in mm in mm / 5/ - -.59.7.7 9.05.75.0 50.0 5/ - -.7.7 9.05.75.0 50.0 5/- 5/- 7/-0 7/-0-0 7/-0 9/- - -/- -5/- -- -- --.7.5.. 5.. 7. 9.90 5.9. 7..0 5.97 7/ 7/ 9/ / - - - - -... 5.7 5.7 0..5.9.5 5.97 5/ 7/ 7/ 9/ / / - - - -... 5.7 7. 7...5.0 7. 57.5 7.0 A. 5...7.7.... 50.0 7.5 B 0.9 5. 5. 7.7.5 9.0 9.0.. 5..7..9. 0. 0.9.. 5.. 9.7 55..07. L 7.7.9 5.05 7.59.5 9. 9. 5.97 5.. 77.5 90. 0.57 AN Bulkhead Union UBA Connects fractional tube to AN flared tube UBA - UBA - UBA - UBA - UBA - UBA - UBA 0-0 UBA - UBA - AN Tube Straight Panel Panel Flare Size Thread h H A L L Hole Max in mm in mm T(U) in mm in mm rill Size Thickness - -.7 9.05.75.0 50.0 - -.7 9.05.75.0 50.0 5/- 7/-0 9/- - -/- -5/- -- -- --.77. 7. 9.90 5.9. 7..0 5.97 5/ -/ - - - - 5.7 9.05. 0..7 7. 57.5 7/ 9/ / - - - -.. 7...5.0 7. 57.5 7.0.7 5..7.... 50.0 7.5 0.5. 9.7 55.. 0..7 9..9. 7.5. 5. 9. 57.5.75 5.7 7. 9 5. 9.5 7.75 0.7 9.7.5 5. 5...5..9 57.0 7.5 9.7..50. 9..79.7.7 9..7 0..7.7 9.05 9.05 9.05 9.05 AN Adapter AA Connects factional k-lok AA - AA - AA - AA - AA - port to male AN AN Tube Straight Flare Size Thread h H in mm in mm T(U) in mm in mm.7.7 5/- 7/..7 7/-0 9/. 7/. 7/-0 9/. 9/. 9/- / 7. / 7. -.. A.7 5.7 5.7..59.. 5.7 7.5..5 9.05..9.75

SA Fittings k-lok SA Straight O-Ring Seal Fittings are of positionable feature and provide connection tube to straight thread boss. Further this has an advantage of eliminating welding and brazing process when used as bulkhead fitting on thin wall tanks or vessels. These fittings are designed and manufactured to SA standards as below: Male or xternal Fitting nd imensions to SA J5 Straight thread to SA J75 (equivalent to ANSI B, or ISO R7) Female or Internal Straight Thread Boss to SAJ9. See diagram below. U IA R 0.00(0.) 0.05(0.75) Z 00 5 5 K K SA Internal Straight Thread Boss Y O Recommended spotface dia This surface shall be square with the thread pitch dia within 0.00(0.0) FIR. When measured at 0 dia S O-Ring position after Installation Lock Nut Back-Up Washer P J THQ Min boss height IA-This dim applies only when tap drill can not pass thru entire boss, O-Ring etails of SA Internal Straight Thread Boss Nom. / 5/ - - Thread Size 5/- - 7/-0-0 9/- - - -/- -/- -5/- --/ -- --....0 7.5 0.0.5.0.0.0 7.0.0 70.0 J 0.0 0.0.5.5.7..7 9.0 9.0 9.0 9.0 9.0 9.0 K ( ).9.9...5.5.5...... a. iameter U shall be concentric with the thread pitch diameter within 0. full indicator reading (FIR)and shall be free from longitudinal and spiral too marks. Annular tool marks up to.5 Micro meters max. shall be permissble. b. This is the Maximum recommended spotface depth to permit sufficient wrench grip for the proper tightening of the fitting of locknut. c. If the face of the boss is on a machined surface, dimensions Y and S need not apply as long as R 0./ 0.75 is maintained to avoid damage to the O-Ring during installaton. d. Tap drill depths given require the use of bottoming taps to produce the specified full thread lengths. Where standard taps are used, the tap drill depths must be increased accordingly. O 5 5 5 70 P d.0.0.0.0 5.5 7.5 0.0.0.0.0.0.0.0 U a ( ) -0 9. 0.7..0 5. 0..9 9.. 5.5.5 9. 5.7 Y c 7 9 0 5 9 5 5 S bc Max............. Unit:mm Z ( ) 5 5 5 5 5 5 5 5 O-Ring and straight thread size for SA Fitting Bosses Nominal / 5/ - - Port Size 5 0 0 Thread Size 5/- - 7/-0-0 9/- - - -/- -/- -5/- -- -- -- Size No. 90 90 90 905 90 90 90 9 9 9 90 9 9 O-Ring I.. Cross Section inch inch 0.9 0.0 0.0 0.0 0.5 0.07 0. 0.07 0. 0.07 0. 0.07 0.755 0.097 0.9 0..0 0..7 0..75 0..70 0..7 0. Installation Instruction Step. nsure the locknut is fully raised. Step. Lubricate the O-Ring with a light oil or petroleum and turn the fitting into the straight thread boss until the metal washer is in contact with the boss Step. Position the fitting by backing it out (not more than turn counter-clockwise)until the k-lok fitting is oriented Iin the desired direction. Step. With a back up wrench, hold the wrench pad and tighten the locknut until the washer is set against the face of the boss.

SA Male Connector MCS Connects fractional tube to SA straight thread boss Straight Thread h H in mm T(u) in mm in mm MCS -U.7 5/-. 7/. 7/. MCS -U 7/-0. 9/. 9/. MCS -U 9/-. / 7. 9/. MCS -U -.. 9/. MCS -0U -. 9/. MCS 5-5U 5/ -0 5. 5.7 5.7 MCS -U 7/-0 5.0 5.7 / 7. MCS -U 9/- 7. / 7. / 7. MCS -U - 7.. / 7. MCS -0U - 7. / 7. MCS -U 9/- 7. / 0.. MCS -U - 0... MCS -0U - 0.. MCS -U -/- 0. -.75. MCS 0-U 5.7-0. 5/. MCS 0-0U 5.7 - MCS -U 9.05-0. -/.9 -.57 MCS -U 9.05 -/- 5.7 -.75 -.57 MCS -U. -/-. -.9 -.75 MCS -U -/-.7 -.9 -.0 MCS -U -5/-.5 -.0 -.0 MCS 0-0U -.75 -- 7. - 7. - 7. MCS -U -.0 --.0-5.9-57.5 MCS -U 50.0 -- 5.97-7.0 A 5. 5. 5. 5...7.7.7.7.........90... 50.0 7.5 B 5. 7.7 7.7 7.7 7.7.5 9.0 9.0 9.0 9.0... 5..7..7.9 0..7 7..9 9.7.75.79.95.75.79..75 5.05 5...... 50.5. 7. 9. 9.90.7 9. 9. 9.90.7 9.90.7.9.7.7.9.9.9.9.9.9.9 L 9.97.0 5.5 7.59 0..79 5.5 7.0 9.. 9..9.95 9.0.9 5. 5.97 9.0 9.0 5. 5.5. 77.7 0.0 O-Ring Uniform Size Number -90-90 -90-90 -90-905 -90-90 -90-90 -90-90 -90-9 -90-90 -90-9 -9-9 -9-90 -9-9 Positionable SA Male lbow LS Connects fractional tube to SA straight thread boss LS -U LS 5-5U LS -U LS -U LS -U LS 0-0U LS -U LS -U LS -U 5/ LS 0-0U- LS -U- LS -U Straight Thread h H H in mm T(u) in mm in mm in mm A B L L 7/-0. 9/. 9/. 5. 7.7.0 9.90.. -0 5. 9/. 5.7 5.7..5. 9.90 0. 9. 9/- 7. 5.7 / 7. / 7..7 9.0..7.00. - 7. / 0. / 7...7 9.0 7..79 7. - 0. / 0.... 7. 7.59 7. 5.7 -. 9.. 9.. 9.05 -/- 5.7 -/.9 -.57 -.75...7.0.7. -/-. -.75 -.75 -.9.90.0.7. 50.5-5/-.5 -.9 -.0 -.0...5.7 50.5 5.59.75 -- 7. -/.7-7. - 7... 5.7.7 7. 5..0 --.0 50.0-57.5-5.9 50.0 5. 50.0.7 77 0.5 50.0 -- 5.97-7.0-7.5.7.7 07. 7. K.5. 0.0.5.5 9..57 0..9 5.. 0. O-Ring Uniform Size Number -90-905 -90-90 -90-90 -9-9 -9-90 -9-9

Positionable 5 SA Male lbow LBS Connects fractional tube to SA straight thread boss LBS -U LBS -U LBS -U LBS -U LBS -U Straight Thread h H H in mm T(u) in mm in mm in mm A B L L K 7/-0. 9/. 9/. 5. 7.7. 9.90.5.5 9/- 7. 5.7 / 7. / 7..7 9.0 0.57.7.9-0. / 0.....00. 9.05 -/- 5.7 -.5 -.5 -.75. 9.7.7 9.7 7. -5/-.5 -.9 -.0 -.0.. 5.0.7 50.5.5 0.0.5.57.9 O-Ring Uniform Size Number -90-90 -90-9 -9 Positionable SA Male Run Tee TRS Connects fractional tube to SA straight thread boss TRS -U TRS -U TRS -U TRS -U TRS -U TRS 0-0U TRS -U TRS -U Straight Thread h H H in mm T(u) in mm in mm in mm A B L L K 7/-0. 9/. 9/. 5. 7.7.0 9.90.. 9/- 7. 5.7 / 7. / 7..7 9.0..7.00. - 0. / 0.... 7. 7.59 7. 9.05 -/- 5.7 -.9 -.5 -.75...7.0.7-5/-.5 -.9 -.0 -.0...5.7 50.5 50.5.75 -- 7. -/. - 7. - 7... 5.7.7 7. 5..0 --.0 50.0-57.5-5.9 50.0 5. 50.0.7 77 0.5 50.0 -- 5.97-7.0-7.5.7.7 07. 7. - -.5 0.0.5.57.9 5.. 0. O-Ring Uniform Size Number -90-90 -90-9 -9-90 -9-9 Positionable SA Male Branch Tee TBS Connects fractional tube to SA straight thread boss TBS -U TBS -U TBS -U TBS -U TBS -U TBS 0-0U TBS -U TBS -U Straight Thread h H H in mm T(u) in mm in mm in mm A B L L K 7/-0. 9/. 9/. 5. 7.7.0 9.90.. 9/- 7. 5.7 / 7. / 7..7 9.0..7.00. - 0. / 0.... 7. 7.59 7. 9.05 -/- 5.7 -/.9 -.5 -.75...7.0.7-5/-.5 -.9 -.0 -.0...5.7 50.5 5.59.75 -- 7. -/. - 7. - 7... 5.7.7 7. 5..0 --.0 50.0-57.5-5.9 50.0 5. 50.0.7 77 0.5 50.0 -- 5.97-7.0-7.5.7.7 07. 7. - -.5 0.0.5.57.9 5.. 0. O-Ring Unifom Size Number -90-90 -90-9 -9-90 -9-9

O-Seal Connector k-lok O-ring seal fittings provide leak-tight sealing on both vacuum and high pressure with a smooth & flat surface perpendicular to the threaded port to ensure metal to metal contact. The standard Buna N O-ring is contained in a precision groove to prevent O-ring extrusion at high pressure and for a controlled squeeze in a vacuum service. Raised Port Counterbored Port Recessed Port A Fig. A Fig. B Fig. A C Mounting imensions for O-seal connectors k-lok COS -U COS -U COS -U COS 5-5U COS -U COS -U COS -U COS -U COP - COP - COP - COP - COP - COP - Straight Thread 5/- - 7/-0-0 9/- - -/- -5/- - - - - - - Pipe Thread - - - - - - - - NPT NPT NPT NPT NPT NPT Inch 0.50 0.5 0.9 0.75 0..00..9 0.9 0.9 0.7.00.. A mm.7. 7.5 9. 0.. 5..9 7.5 7.5...0.0 iameter B Inch mm 0.59 5.0 0.. 0.7 9. 0.9. 0.97...5.9.7 5. 0.7 9. 0.7 9. 0.97....0..0 Inch 0. 0.75 0..0.09..75.0 0. 0..09..5.5 C mm. 9... 7.7..5 5... 7.7..9.9 Inch 0.09 0.09 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. epth Max. Max. mm Inch mm. 0. 5.. 0. 5.. 0. 7.. 0.. 0.. 0.. 5. 0.50.7 5. 0.5.. 0. 7.. 0. 7.. 0.. 0.. 5. 0.. 5. 0.. When installing an O-ring seal fitting:. Hand-tighten it until the squeeze on the O-ring can be felt during the last turn. Snug the fitting lightly with a wrench When connecting & disconnecting the tubing to the O-ring fitting:. Use a back-up wrench on the fitting hex so it does not turn while the nut is being tightened at the tubing connection.. When disconnecting the tubing also use a back-up wrench so the fitting does not turn. For a recessed port, use a thin back-up wrench (")to hold the fitting hex (Fig.). O-Seal Temperature Ratings NBR (e. g. Perbunan ) FKM (e. g. Viton ) PTF (e. g. Telflon ) -0 C to 0 C (-0 F to 0 F) - C to 0 C (-0 F to 00 F) -0 C to 0 C (-7 F to F)

O-Seal Straight Thread Connector COS Connects fractional tube to female straight thread COS - U COS - U / COS - U COS 5-5U 5/ COS - U COS - U COS - U COS - U Straight Thread h H A B L in mm T(u) in mm in mm.7.7 9.05 5/-0-7/-0-0 9/- - -/- -5/-..0. 7. 0. 5.7.5 9/ 5/ - - -. 5.7 9.05...57.0.5 7/ 9/ / - -.. 5.7 7...5.0.7 5...7... 5..00 7.7.5 9.0.. 7. 0.9.7 5.05 5.. 5.97. 0..7.9.9...7.9.5 0.. 5.97 5. 5. O-Ring Uniform Size Number -0-0 -0 - - - - -5 O-Seal Pipe Thread Connector COP Connects fractional tube to female NPT thread T h H A B L in mm *(NPT) in mm in mm COP - N COP - N COP - N COP - N COP - N COP - N COP - N.7... 7. 7. 7. 0. 5/ 5/ - -5/ -5/ * ISO Paralled Threads are available upon request. 9.05 9.05...5.. 7/ 9/ 9/ / / /... 7. 7. 7.. 5. 5..7.7.7. 5. 7.7 7.7 9.0 9.0 9.0. 7. 0.9.5.0 9. 9. 7. 7. 0....7 5.05.5 9.7.0.99 9.7 O-Ring Uniform Size Number -0-0 - - - - -

Male Pipe Weld Connector CW Connects fractional tube to pipe CW -P CW -P / CW -P CW -P CW 5-P 5/ CW 5-P 5/ CW -P CW -P CW -P CW -P CW -P CW -P CW 0-P CW -P CW -P CW 0-0P - CW -P - CW -P Male Pipe Size P h H in mm Nom. O.. in mm in mm.7.7 5.7 9.05.75.0 50.0 - - 0.9 0.9 0.9.7 0.9.7.7 7.5. 7.5..7..7.0.. 0...0.. 5.0 7. 7. 7. 0. 0. 0. 5.7.5 7..0 7.75 7/ 7/ 9/ 9/ 9/ / / -/ 5/ -/ - - - -..... 5.7 7.. 0...9..9.9.5 5.9 7/ 9/ 9/ / / / - - -... 5.7 5.7 7. 7. 7.....5.0 50.0 57.5 7.0 A.7 5. 5....7.7.7....... 50.0 7.5 B 5..00 7.7 7.7.5.5 9.0 9.0 9.0.. 5..7.7. 0..7..5.5..7. 0.. 0. 50.0 55..7 7.0.....05. 9.05 9.05 9.05 9.05.7.7..9 L...7 7..0.0 9.7 9.7.. 9.0 50.5 9.0 50.5. 77..90.5 Connects metric tube to pipe Male Pipe Size P Nom. O.. h H CW M-P CW M-P CW M-P CW M-P CW M-P CW M-P CW M-P CW 0M-P CW 0M-P CW 0M-P CW M-P CW M-P CW M-P CW M-P CW 5M-P CW M-P CW M-P CW M-0P CW M-P k-lok 0 0 0 5 - - Welding information 0.9 0.9 0.9.7 0.9.7..7 7.5..7 7.5. 7.5......... 5... 7. 7. 0..9.7.5..7 5 5 7 55 9 9 9 0 50 0 A.9.7 5. 5.... 7. 7. 7.....0 9. B 5.. 7.7 7.7....... 0..7. 7...5.....0.9.9 0. 5..0 9.7 9.7 9.7. 9.7. 9.0.. 9.0.. 9.0. 9.0 9.0 9.0.9. L 9.7 0.7. 7...7. 0.9 0. 5.7.... 9.0 9.0 50.5 79. 9. k-lok weld ends are constructed to Schedule 0 wall or greater. The first step is to remove the nut and ferrules from the k-lok fitting to protect them from weld heat and cover the threads with a protective device (i.e. another nut or a plug) P to protect the k-lok port threads & sealing surface from weld spatter. Only finger-tighten the protective device so that you can use it many times. The second step is to tack weld at four positions 90 apart to hold the fitting in place to ensure alignment and concentricity of the components, then complete the weld.

Male Pipe Weld lbow LW Connects fractional tube to pipe LW -P LW -P LW -P LW -P LW -P Male Pipe Size P h H in mm Nom. O.. in mm in mm.7 9.05 0.9.7.7..7.. 7. 0. 5.7 / -/ 5.7 0..9 9/ 9/ / -.. 7...5 A 5. 5..7.. B 7.7 7.7 9.0 5 5..90 9.7 L L.. 9.05 9.05.9.9 0..0 9.7.79..0. Tube Socket Weld Connector CSW Connects fractional tubes CSW - CSW - CSW - CSW - CSW - CSW - h H in mm in mm in mm.7 9.05.. 7. 0. 5.7.5 7.7.7 5.7 9.05.7.7 7/ / -/ -. 5.7 0..9.9 7/ 9/ / - -.. 7...5.0 A 5..7... B 5. 7.7 9.0..5. 0. 0.9.7 0.. 0..9.9.9. 7.7. 9.05 L.95.5 7.59.. 5.57 Tube Socket Weld lbow LSW Connects fractional tubes LSW - LSW - LSW - LSW- LSW- h H in mm in mm in mm 9.05. 7. 0. 5.7.5 5.7 0.57.9 5.05 / -/ - 5.7 0..9.9 9/ / - -. 7...5.0 A 5..7... B 7.7 9.0. 5..90 9.7. L L 7.7. 9.05.9 0..0 9.7 9.0 5..90 9.7.

Plug P for plugging unused fitting port Installation Instructions. Remove the nut and ferrules from the body. With a wrench, turn from the finger-tight position, ( turn for ", /" and mm, mm and mm) Cap C Installation Instructions. Insert the tube end into the Cap. With a wrench, - turns from the finger-tight position, ( turn for ", /" mm and mm) for capping tube end fractional P- P- P- P- P-5 P- P- P-0 P- P- P- P-0 P- P- metric Width P-M P-M P-M P-M P-M P-0M P-M P-5M H in mm in mm /.59 5/.7 7/. /.7 9/. 5/ 5.7 / 7.. 5.7 9.05 -.5. -.75 -.0 -.75-7. -.0-57.5 50.0 7.0 0 5 across flat H 9 P-M P-M P-0M P-M P-M P-M P-M P-M Width across flat H Cap end of fractional tube h H A B L in mm in mm in mm C- C- C- C- C-5 C- C- C-0 C- C- C- C-0 C- C- / / 5/ - -.59.7.7 5.7 9.05..75.0 50.0 5/ 7/ 7/ 9/ / 5/ -/ -/ - - - -... 5.7 0...9 0..9.5 5.9 5/ 7/ 9/ / - - - - -.. 5.7 7...57.75.0 7. 57.5 7.0..7 5...7....90.. 50.5 7.5 0.9 5..00 7.7.5 9.0.. 5..7.0..7.00 7.0. 9.05 9...7.. 7. 9.7. 0.0....5 9. 9.97.9.0.5 5..5. Cap end of metric tube C-M C-M C-M C-M C-M C-0M C-M C-5M C-M C-M C-0M C-M C-M C-M C-M C-M h H 0 5 0 5 7 0 0 5 55 9 0 50 0 0 0 50 0 A B L.9.9.7 5.. 7...0.0...0 9. 5. 5.. 7.7..5...5.5.7 5.7 7.0 9.0 9.0 9. 9...9.9. 7.7. 7. 0. 0....5. 9. 9.9 9.9..0.0.5.5 55. 5.

Tube Insert I for Nylon or Soft Plastic Tubing fractional I - I - I - I 5- I 5- I 5- I - I - I - I - I 0- I 0- I - I -0 I - in mm in mm /.7.7.7 /.7 5/.7 5/ /.7 5/ /.7.7.7 5.7 5.7 9.05 9.05 5.7. 9.05...55..0..0.. 7.7 7.7.7.7. 7.5 Installation Instructions The k-lok Tube Insert supports the soft plastic tubing, thus the tubing does not collapse when the ferrules deform it. When you select a size of Tube Insert, check if the tubing O.. and I.. conform to those of the tube insert. metric I M-M I M-M I 0M-M I M-M I M-0M 0 0..... Nut N fractional N- N- N- N- N-5 N- N- N-0 N- N- N- N-0 N- N- H in mm in mm / / 5/ - -.59.7.7 5.7 9.05..75.0 50.0 5/ 7/ 9/ / - - - - -.. 5.7 7...57.75.0 7. 57.5 7.0 L 0.9.9.. 7.5 7.5 7.5 7.5 0.57.75.0 5. metric N - M N - M N - M N - M N - M N - 0M N - M N - 5M N - M N - M N - 0M N - M N - M N - M N - M N - M 0 5 0 H 9 0 50 0 L.90.90.90.50 5.0 7.0 7.0 7.0 7.0 7.0 7.0 0.0 0.0.0 0.0

Front Ferrule FF fractional FF- FF- FF- FF- FF-5 FF- FF- FF-0 FF- FF- FF- FF-0 FF- FF- in / / 5/ - - mm.59.7.7 5.7 9.05..75.0 50.0 metric FF-M FF-M FF-M FF-M FF-M FF-0M FF-M FF-5M FF-M FF-M FF-0M FF-M FF-M FF-M FF-M FF-M 0 5 0 Bcak Ferrule FB fractional FB- FB- FB- FB- FB-5 FB- FB- FB-0 FB- FB- FB- FB-0 FB- FB- in / / 5/ - - mm.59.7.7 5.7 9.05..75.0 50.0 metric FB-M FB-M FB-M FB-M FB-M FB-0M FB-M FB-5M FB-M FB-M FB-0M FB-M FB-M FB-M FB-M FB-M 0 5 0 Ferrule Set FS fractional FS- FS- FS- FS- FS-5 FS- FS- FS-0 FS- FS- FS- in / / 5/ mm.59.7.7 5.7 9.05. metric FS-M FS-M FS-M FS-M FS-M FS-0M FS-M FS-5M FS-M FS-M FS-0M FS-M FS-M 0 5 0 Gap Gauge for Pull-up Inspection IG k-lok maintains unbelievably tight tolerance on its each and every part. k-lok tube fittings are monitored and gauged throughout process. This assures k-lok consistency and makes k-lok fittings gaugable. This no-go gauge is the useful tool to inspect if the fittings are pulled up - turns from the finger-tight position. When the gauge doesn't fit the gap between the nut and body hex, the fitting is tightened - turns from the finger-tight position. If the gauge fits the gap, the fittings is not fully tightened. Multiple Size Gap Gauge IG Applicable k-lok ", ", ", mm, 0mm, mm

HS-A k-lok Hydraulic Swaging Unit Model No. HS-A For over " Stainless steel and Carbon Steel k-lok fittings k-lok offers a unique & versatile Swaging unit that is easy to operate and allows pre-swaging for " to " (mm to mm). It will save you time and money and even storage space. From now on, hand carry only one unit not many. Our k-lok Swaging unit is designed to pre-swage the front & back ferrule onto the tubing prior to final assembly into a fitting with little physical effort other than the manual pull-up. This unit provides consistent make-up and a reliable leak-free seal. Swaging dies are available from " to " (mm to mm). The k-lok Swaging unit consist of a Hydraulic hand pump, Pump hose, swaging head and swaging dies and are contained in the sturdy steel case. Swaging unit Arm Arm Pin Release position Operating position ARM GRIPPR Lock Nut. Swaging Head Pressure Bleed Valve. JS 5. ie Fixing Bolt. Ratchet Wrench HS-A part list, part number and standard Qty No. Part List Swaging Head HS-SH Hydraulic Hand Pump HS-H-0K Hose HS-PS-.M JS consisting of I and JIG See below 5 ie Fixing Bolt HS-B-5M Ratchet Wrench HS-RW 7 Allen Key HS-K-5M Plastic Carrying Case HS-PC 9 ie & Jig Case HS-C 0 Operating Hannal HS-A-manual Qty -. Hose. Hydraulic Hand Pump Vent/Fill Cap ip Stick Bypass Valve. JS 7. Allen Key ie, Jig and recommended tubing wall thickness k-lok Fitting " " " " -" -" ie 0 0 Jig J J0 J J J0 J J ie & Jig Set Part No. JS JS0 JS JS JS0 JS JS Recommended & Max. Wall Thickness S Tubing Carbon Steel Tubing Max. Max. 0.09" 0.05" 0.05" 0.0" 0.0" 0.095" 0.09" 0.0" 0.095" 0.09" 0.0" 0.5" 0." 0." 0.09" 0.05" 0.05" 0.0" 0.05" 0.0" 0.095" 0.0" 0.095" 0.09" 0.0" 0.0" 0.0" 0.0" How to Order Note : For metric ies and Jigs, suffix M to the designated size. e.g. M and JM for mm die & Jig. Please order our Unit No. HS-A and specify the fitting sizes. e.g. HS-A and ", ", -", -", ". Then the die and Jig Set of JS, JS, JS0, JS and JS shall be included in the steel case. Note : The carrying case is designed to contain sets of die and Jig maximum..

INSTALLATION INSTRUCTIONS k-lok is supplied finger-tight and ready for immediate use. Therefore fitting disassembly is not necessary for Step. Make sure the nut is finger-tight. Put the tubing into the k-lok tube fitting until the tube end bottoms on the shoulder inside the fitting. Step. 0 9 7 5 Tighten the nut - turn with a wrench by holding the fitting body with a back up wrench. Marking the nut at the 9:00 o' clock position may be necessary for counting the number of turns as the mark will stop at the o' clock position after - turns. * Only turn from finger tight is required for sizes ", /", mm and mm. Re-assembly Instructions k-lok connections can be used many times. Prior to re-assembly, ensure the components are clean and free of defects. Step. Insert the tubing with pre-swaged ferrules and a nut into the body until the front ferrule seats firmly in the fitting body. Step. Hand tighten the nut. Then rotate the nut with a wrench to the original - tight position(sharp rise in torque is felt at the original position) and snug slightly with a wrench. Tube handling during installation. o not force the tubing into the fitting when it does not smoothly go in. It may be a deformed oval or have burs at the tubing end.. It is important to use the proper tube cutter and maintain a sharp cutting wheel on it always.