Weishaupt Monarch oil burners Sizes 1 and 3 1/2002 GB

Similar documents
Weishaupt Monarch oil burners Sizes 5 to 11 1/2002 GB

Weishaupt Monarch oil burners Sizes 5 to 11 1/2002 CA

product Oil burners, 1-11 monarch burners, sizes 1-11 ( kw) simply reliable Information on oil burners

product Information on oil, gas and dual fuel burners Industrial burners 1,000 11,700 kw flexible and reliable

product Digital combustion technology Weishaupt oil burners, WL10 to WL40 ( kw) Information on compact burners

Weishaupt WKGL70 dual fuel burner Version 3LN (Low NO x ) multiflam 1/2003 GB

Weishaupt oil burners Sizes 30 to 70 1/2003 CA

Weishaupt gas burners Sizes 30 to 70 Version NR (NO x reduced)

product Digital dual fuel burners Weishaupt dual fuel burners WGL30-C and WGL40-A ( kw) Information on compact burners

product Compact and powerful Weishaupt monarch oil burner, WM-L20 ( kw) Information on oil burners

product WM 20 for oil, gas and dual-fuel WM 20 monarch burners ( kw) compact and powerful Information on oil, gas and dual-fuel burners

product Digital combustion technology Weishaupt gas burners, WG10 to WG40 ( kw) Information on compact burners

product WM 30 for gas, oil, and dual-fuel WM 30 monarch burners ( kw) powerful and versatile Information on gas, oil, and dual-fuel burners

product WM 10 oil, gas and dual fuel version Weishaupt monarch WM10 burners flexible application Information on oil, gas and dual fuel burners

product WM 20 for gas, oil, and dual-fuel WM 20 monarch burners ( kw) compact and powerful Information on gas, oil, and dual-fuel burners

Oil, Gas and Dual Fuel Burners

RL/M BLU SERIES. Low NOx Modulating Light Oil Burners FIRING RATES. LOW NOx T. M 190/ kw M 223/ kw

info Increased capacity for industrial applications Weishaupt monarch gas burner WM-G10 version ZMI ( kw) Information on industrial burners

info The intelligent control concept W-FM 100 and W-FM 200 combustion managers Information on digital combustion management

Kerosene - oil burner

Oil - kerosene burner

RIELLO 40 F SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL. F kw F kw F kw

PRESS G SERIES. Two Stage Light Oil Burners FIRING RATES

PRESS P/N - P/N ECO SERIES

info The intelligent control concept W-FM 100 and W-FM 200 combustion managers Product information on digital combustion management

Light oil - kerosene burner

CODE MODEL TYPE G3BF 490T G5BF 492T G5BF 489T53

RDB SERIES. One Stage Light Oil and Kerosene Burners FIRING RATES LIGHT OIL

info NO x emissions <15 ppm 4LN version gas burners (with Flue Gas Recirculation) Information on Ultra Low NO x gas burners

info WK-series industrial burners Industrial burners WK40 to WK kw to 32,000 kw Information on Duoblock burners

RES G MRBLU SERIES. Low NOx One Stage Light Oil Burners FIRING RATES. LOW NOx LIGHT OIL

TWO STAGE PROGRESSIVE AND MODULATING GAS BURNERS RIELLO 40 GS/M SERIES GS 10/M 22/ kw GS 20/M 43/ kw

RS SERIES. Two Stage Progressive Gas Burners FIRING RATES

RS/M SERIES. Modulating Gas Burners FIRING RATES

CODE MODEL TYPE PRESS GW 605 T80

ONE STAGE GAS BURNERS RDBS SERIES

GULLIVER BSD SERIES. Low NOx Two Stage Gas Burners FIRING RATES. BS1D 16/19 52 kw BS2D 35/40 91 kw BS3D 65/ kw BS4D 110/ kw.

RS/1 SERIES. One Stage Gas Burners RS 34/1 MZ RS 44/1 MZ kw kw GAS

Installation- and maintenance instruction B80-2/3

DB Series. Technical Data Leaflet. Industrial Dual Block Oil, Gas and Dual Fuel Burners. Industrial TS0086UK00

Installation- and maintenance instruction BENTOFLEX ST 108 PL

Doing more for clean environment and energy saving

Installation- and maintenance instruction ST120 S75/21

Installation- and maintenance instruction BENTOFLEX ST120KAV

Valve monitoring system VDK 200 A S02

GULLIVER BS SERIES. Low NOx One Stage Gas Burners FIRING RATES. BS kw BS kw BS kw BS kw.

Installation- and maintenance instruction B20KA/K

Oil, gas and dual fuel burners. Burner series

Gas burner Dual fuel burner. Gas burner. Series RG GG MG. Dual fuel burner. Series MK

RS/E-EV MZ SERIES. Modulating Gas Burners FIRING RATES

Installation- and maintenance instruction B20K-2

Oil, Gas and Dual Fuel Monoblock Burners

product WM 10 for gas, oil, and dual-fuel WM 10 monarch burners ( kw) versatile performance Information on gas, oil, and dual-fuel burners

all combustible gases and fuel oil, extra light gases up to 1 bar, fuel oil up to 40 bar Fuel Connection gases ½, fuel oil ¼

KOLHAPUR FOUNDRY & ENGINEERING CLUSTER

TECHNICAL DOCUMENTATION WOLF AIR HEATERS LH-EC / LH. 30m 3 /h

AMR. GB-Ganz Tüzeléstechnikai Kft. MODULATING DUOBLOCK BURNER FAMILY

TEAMTEC INCINERATORS Market leaders since More than units sold worldwide

Installation- and maintenance instruction BENTOFLEX ST133K


VAILLANT SPARE PART CATALOGUE

FD68 BURNERS SELECTION GUIDE & ENGINEERING SPECS

Installation- and maintenance instruction B20KAV/KV

OIL BURNERS MAIOR P 45 AB. techniques for energy saving MODEL. HYDRAULIC SYSTEM 220/380 V 60 Hz LB

822 NOVAMIX GAS FLOW RATE ADJUSTMENT AS A FUNCTION OF THE AIR FLOW GAS/AIR RATIO 1:1 DOUBLE AUTOMATIC SOLENOID SHUT-OFF VALVE

TWO STAGE GAS BURNER GULLIVER RSD SERIES RS5D 160/ kw

Installation- and maintenance instruction BENTOFLEX ST133KA/K

X4 Installation and Operation Manual - POWER FLAME INCORPORATED

RIELLO 40 GS SERIES. One Stage Gas Burners FIRING RATES. S kw S kw S kw S kw

LOW NOx TWO STAGE GAS BURNERS GULLIVER BSD SERIES BS1D 16/19 52 kw BS2D 35/40 91 kw BS3D 65/ kw BS4D 110/ kw

EC 200 EC 300 GE 360 GE 400 GE 600 L-S BM

Installation- and maintenance instruction B20KA/K

Heating and Gas Installations - December 2014

RIELLO 40 FS SERIES. One Stage Gas Burners FIRING RATES. FS kw FS kw FS kw FS kw FS kw FS kw GAS

SIHI LPH-X - Liquid Ring Vacuum Pump Two Stage

ONE STAGE GAS BURNER GULLIVER RSF SERIES RS5F kw

CODE OF GOOD PRACTICE

Installation- and maintenance instruction B45A2.2

OIL BURNERS. MINOR 1 Snorkel 240 Volt 50 Hz

TWO STAGE LIGHT OIL BURNERS PRESS G SERIES

3 Edition Product brochure GB AGA

Electromotoric Actuators

Small diaphragm vacuum pumps

Emprendimiento Fénix Product Catalogue

SIHI LPH-X - Liquid Ring Vacuum Pump Two Stage

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

Tightness control TC. Product brochure GB Edition 12.10

Spare parts catalogue GB 07/2008. Wall-hung boilers ecotec VU 466/4-5 VU 656/4-5

PRODUCT RANGE A COMPLETE RANGE OF BURNERS FROM 17 TO kw

available in battery up to 4 units for a total of 560 kw

Mobile Diesel Heaters GRY-D / GRY-I Service Training Course

Eurovacuum EVR Series

Section 3 Technical Information

Actuators. Building Technologies Division

GAS BURNERS BLU 3000 PR BLU 4000 PR

TWA S/K/P. Incorporating. R410A Air cooled water chillers with axial fans and scroll compressors from 189 kw to 1007 kw

Combination controls CG 10

G72x Series Direct Spark Ignition Controls

VAL6 KBE5S. Service Manual

Weishaupt Low NOx Solutions for Boiler Applications

Transcription:

Weishaupt Monarch oil burners Sizes 1 and 3 1/ GB

Description Weishaupt Monarch oil burners are of the fully automatic pressure atomising type. Their design has been carefully considered down to the smallest detail and has been proved successful over and over again. They meet all the demands for safety, reliability and low cost servicing. Weishaupt oil burners are type tested to EN 7. The burners are distinguished by a variety of interesting features: Range of application - 5 kg/h (71-775 kw) Automatic sequence of operations Stable fan characteristics good combustion results Air regulation on pressure side Air damper closed on burner shutdown Quiet operation Complete pre-wired integral switchgear Hinged burner casing Combustion head can be withdrawn when the burner is hinged open The design of the burner makes installation, adjustment and servicing easy Construction All the components are assembled in one unit. The motor drives the fan and the fuel pump. All the equipment used for the regulation of fuel and air is clearly arranged and easily accessible. The burners can be hinged to the left or right, which simplifies service work on the combustion head, diffuser, nozzles and ignition electrodes. Application The burners can be used on hot water boilers, steam boilers, air heaters and for certain heating processes. The burners are used in particular on modern, high rated boilers, as they are capable of overcoming high combustion chamber pressures. RL burners are preferably used where there is a continually changing heat demand. Fuels Distillate oil and medium oil to DIN 51 3 can be fired. Viscosity: Types Monarch L and RL - < mm /s at C Type Monarch M - 75 mm /s at 5 C Regulation On L and M type burners, the regulation of oil and air takes place as follows: two stage, nozzle head with two nozzles and a motor controlled, quickly opening air damper. three stage, with three nozzles and a motor controlled, slowly opening air damper. The RL burner alters its capacity slowly (sliding). Fuel and air are controlled in compound. The burner can, depending on the controller and servomotor, be either: sliding two stage ( s running time) or modulating ( s running time) With sliding two stage regulation, the partial and full load positions are fixed within the burner operating range. The burner slides to one position or the other, depending on the appliance demand, and there are no rapid changes of fuel throughput. By fitting a suitable controller into the control panel, the burner can be altered to modulating operation. Modulating burners operate at any point within the capacity range, depending on the heat demand. On sliding two stage burners and modulating burners, the slow capacity alteration ensures a particularly good matching to the heating appliance. Flame supervision The burner controller automatically sequences the operations and monitors the flame optically via the flame sensor. The controller is mounted on the burner on all standard L and M burners, but can be supplied loose if requested. Together with the control panel, each burner forms one complete unit. On the RL burner, the burner controller is supplied loose for fitting into the control panel. There is no interference with radio and television reception, as radio interference created during ignition is below the permitted limits specified by the relevant EMC standards and regulations. Quiet operation Weishaupt burners operate quietly. All air handling burner parts have been aerodynamically designed, the fuel / air mixing noise is reduced to a minimum and rotors and fan wheels are dynamically balanced. For installations where special emphasis is placed on burners with low noise levels, sound absorbers which reduce burner noise by approximately 7% are available (please ask for details). Oil temperature regulation Residual oil burners are fitted with an oil preheater. The oil is quickly heated to the required atomising temperature, due to the large heat exchange surface combined with a relatively small oil volume. Fast, even heat distribution prevents local overheating and carbonisation of the oil. Heated nozzle head and nozzle recirculation system on residual oil burners All residual oil burners are fitted with a heated nozzle head system. After the oil temperature in the nozzle head has been reached, the burner starts by means of a release thermostat. During prepurge, heated oil flows through the nozzle head and oil line system. This ensures that evenly heated oil is available for flame establishment.

Monarch L distillate oil burner, two stage Integral switchgear (distillate oil burner) Monarch M residual oil burner, preheater side Pressure side air regulation Monarch RL distillate oil burner, compound regulator side Combustion head removable from behind Monarch RL distillate oil burner, regulating drive 3

Included in delivery Industrial version Included in burner delivery L1Z-B L3Z-A (LN) L1T-B M1Z-B RL3-A L3T-A M3Z-A Burner casing with integral air inlet, hinged flange, hinge interlock switch, flange gasket, Weishaupt burner motor, fan, pump, oil hoses, nozzle assembly, combustion head, ignition transformer, ignition cables, ignition electrodes, fixing screws, air damper on fan pressure side. Oil solenoid valve(s) Additional safety valve(s) and oil pressure switch (on burners >3 kg/h) Nozzles(s) Burner controller with flame sensor Type LOA for burners <3 kg/h Type LAL for burners > 3 kg/h Type LFL 1.3 with QRA Terminal strip or Integral switchgear Servomotor for air regulation Servomotor for oil / air regulation with regulating cam (sliding two stage burners type SQM 1.155, s running time; modulating burners type SQM 1.15, s running time), oil regulator, spill type nozzle Oil preheater, heated nozzle head and nozzle recirculation system, filter Parts supplied with integral switchgear The integral switchgear version includes all the parts required for operation. 1 stage 1 control switch with indicating lamp 1 stage control switch with indicating lamp 1 contactor (motor) 1 overload relay (three phase burners only) Industrial execution Where required, a special industrial version of burner sizes 1 and 3 can be supplied. This version is suitable for process applications, e.g. where operating conditions are severe. These burners differ from the standard version as follows: 1 contactor for oil preheater on burner type M1Z-B ( on burner type M3Z-A) Hours counters can be fitted on request at extra cost. 1. Black painted aluminium cover over the terminal box and air regulator.. Waterproof (to IP 5) safety valve and stage 1 and solenoid valves. 3. All external connection cables in conduit.. A separate control panel is provided for the burner switchgear. Explanation of type designation R L 3 Z A version ZMD E = single phase a.c. D = three phase a.c. Type of regulation ZM = sliding two stage Code for burner series Z = two stage, T = three stage Size L = distillate oil EL, M = residual oil M R = variably regulated burner The additional prices are shown on page 1 (special equipment). Only possible for burners without integral switchgear Monarch L distillate oil burner, two stage industrial version Aluminium cover

Model overview Types of regulation Weishaupt Monarch oil burners Quick regulation slow (sliding) regulation Distillate oil burners residual oil burners distillate oil burners two stage three stage two stage sliding two stage modulating L1Z-B and L3Z-A L3Z-A-LN L1T-B and L3T-A M1Z-B and M3Z-A RL3-A Two stage and three stage regulation (Z/T) Standard execution burner Oil is released at start when solenoid valves 1 and open. The burner works at partial load. Full load is reached when solenoid valve 3 / opens. The capacity is regulated by opening and closing solenoid valve 3 or 3 and MV1 MV MV3 MV (Standard execution burner) G ZW K on off Sliding two stage and modulating regulation (ZM) For burner start the oil regulator goes into the ignition load position. A slow running oil / air compound servomotor adjusts the oil quantity up to full load. The servomotor regulates the burner capacity between partial and full load. The difference between sliding two stage and modulating burners is that on the modulating version the servomotor on the burner has a running time of s and on the sliding two stage burner a running time of s. In addition a special controller is fitted into the control panel for modulating operation. P M G K Z G K Z on on off off G = full load, ZW = intermediate load, K = partial load, Z = ignition load Upper graph: sliding two stage Lower graph: modulating 5

Size 1 burner selection Burner rating / combustion chamber pressure Burner type L1Z-B and L1T-B Version E and D Combustion head type L1Z-B M1/5a-15Kx33 L1T-B M1/5a-15Kx3 Rating kg/h -9 kw 7-35 mbar kw - kg/h [EL] 1 3 5 1 3 Burner type L1Z-B and L1T-B Version E and D Combustion head type L1Z-B M1/5a-1Kx33 L1T-B M1/5a-1Kx3 Rating kg/h 1-35 kw 1-15 mbar kw - kg/h [EL] 1 3 5 1 3 Burner type M1Z-B Version E and D Combustion head type M1/5a-15Kx33 Rating kg/h -31 kw 9-35 mbar kw - kg/h [M] 1 3 5 1 3

Burner type M1Z-B Version E and D Combustion head type M1/5a-1Kx33 Rating kg/h 11-37 kw 1-15 mbar kw - kg/h [M] 1 3 5 1 3 The capacities in relation to combustion chamber resistances are maximum values, which were measured to EN 7 on idealised test flame tubes. All ratings data given relate to an air temperature of C and an installation height above sea level of 5 m. The oil throughput information refers to a calorific value of 11.91 kwh/kg for distillate oil EL 11. kwh/kg for residual oil M Shut off devices All burners with an oil throughput > 3 kg/h are equipped with a second solenoid valve (safety valve) as standard. Voltages and frequencies The burners are supplied with single phase 3 V, 5 Hz supply (E), or three phase V, 5 Hz supply (D) as standard. Please indicate other voltages and frequencies required (no extra price). Burner motor standard version Btrop class insulation, to IP5. Motors can also be supplied to F class insulation (additional price on request). Residual oil burners The burner type M1Z-B is not type tested and may only be used outside the Federal Republic of Germany. 7

Size 3 burner selection Burner rating / combustion chamber pressure Burner type L3Z-A, L3T-A, M3Z-A Version L-Burner E, D, E-C and D-C M-Burner D and D-C Combustion head type M/1a-11x Rating kg/h-distillate oil EL 1- kg/h-residual oil M 1.7-.7 kw 1-55 mbar - kw kg/h [EL] kg/h [M] 1 3 5 7 1 3 1 3 5 7 5 7 Burner type L3Z-A, L3T-A, M3Z-A Version L-Burner E, D, E-C and D-C M-Burner D and D-C Combustion head type M5/a-11x Rating kg/h-distillate oil EL 1-5 kg/h-residual oil M 1.9-9 kw 19-775 mbar - kw kg/h [EL] kg/h [M] 1 3 5 7 1 3 1 3 5 7 5 7

Burner type RL3-A Version ZME and ZMD Combustion head type M/1a-11x Rating kg/h 1- kw 1-55 mbar kw - kg/h [EL] 1 3 5 7 1 3 5 7 Burner type RL3-A Version ZME and ZMD Combustion head type _ M5/a-11x Rating kg/h 1-5 kw 19-775 mbar kw - kg/h [EL] 1 3 5 7 1 3 5 7 The capacities in relation to combustion chamber resistances are maximum values, which were measured to EN 7 on idealised test flame tubes. All ratings data given relate to an air temperature of C and an installation height above sea level of 5 m. The oil throughput information refers to a calorific value of 11.91 kwh/kg for distillate oil EL 11. kwh/kg for residual oil M Shut off devices All burners with an oil throughput > 3 kg/h are equipped with a second solenoid valve (safety valve) as standard. Voltages and frequencies The burners are supplied with single phase 3 V, 5 Hz supply (E), or three phase V, 5 Hz supply (D) as standard. Please indicate other voltages and frequencies required (no extra price). Burner motor standard version Btrop class insulation, to IP5. Motors can also be supplied to F class insulation (additional price on request). Residual oil burners The burner type M3Z-A is not type tested and may only be used outside the Federal Republic of Germany. Modulating burners The modulating RL3-A burner is based on the sliding two stage burner. The modulating feature is obtained by fitting a suitable electrical controller into the panel (for price see accessories list). 9

Order numbers, technical information Description L1Z-B L1T-B L3Z-A L3Z-A Version E / D➂ Version E / D➂ Version E / D➄ Version E-C / D-C Order numbers - Version E or EC with integral switchgear ➀ 11 13 3 11 193 3 11 33 1 711 35 1 Version E or EC without integral switchgear ➁ 11 13 11 193 11 33 711 35 Version D or DC with integral switchgear ➀ 11 1 3 11 19 3 11 3 1 711 3 1 Version D or DC without integral switchgear ➁ 11 1 11 19 11 3 711 3 Version ZME without integral switchgear ➁ Version ZMD without integral switchgear ➁ Version E Version E Version E Version E C Burner motor 1Z, 5 Hz Type ECK7 ECK7 ECK/9 ECK/9 Nominal capacity kw.5.5.7.7 Nominal load at A.3.3 Motor pre-fuse A 1 1 1 1 Speed rpm 5 5 5 5 Capacitor µf 1 1 5 5 Version D Version D Version D Version D C Burner motor 3Z3/V, 5 Hz Type DK7/F- DK7/F- DK7/F- DK7/F- Nominal capacity kw.7.7.7.7 Nominal load at 3/V A 3./.1 3./.1 3./.1 3./.1 Motor pre-fuse A Speed rpm Type test No. 5G57/95 5G5/95 5G59/95 5G59/95 Burner controller Type LOA.171 ➃ LAL LOA.171 ➃ LAL Servomotor Type w 155/3 W 155/ w 155/3 w 155/3 Pump Type AE7 AE7 AE97 AE97 Fan galvanised galvanised galvanised galvanised Ignition transformer V x 5 x 5 x 5 x 5 Oil hoses DN Length / mm 1 1 1 1 Connection 3/ 3/ 3/ 3/ Oil preheater Type Heating capacity / kw Weight kg (approx.) 9 9 ➀ ➁ A separate control panel is required on installations to TRD, 7 hr (operation without continuous supervision). The integral switchgear is therefore omitted. On burners without integral switchgear, the burner controller is supplied loose. It can be mounted on the burner at extra cost (see page 1). A terminal strip is provided in both cases. ➂ L1Z-B and L1T-B burners, versions E and D, can be used with this specification up to 3 kg/h. Over 3 kg/h the additional prices for LAL.5 burner controller in lieu of LOA.171 and Solenoid valve as additional shut off device apply (see special equipment, page 1). ➃ Flame monitoring with flame sensor QRB. ➄ L3Z-A burners, versions E and D, can be used with this specification up to 3 kg/h. Over 3 kg/h L3Z-A burners versions E-C or D-C should be used (see page 11). These burners are fitted with an LAL.5 burner controller and an additional safety solenoid valve as standard. 1

L3T-A L3Z-A-1LN RL3-A M1Z-B M3Z-A M3Z-A Version E-C, D / D-C Version D-C Version ZME / ZMD Version E / D Version D Version D-C 711 395 1 711 395 1 13 711 39 1 11 3 3 71 3 3 71 3 3 711 39 11 3 1 1 71 3 71 3 711 373 711 37 Version E Version E C Version ZME Version E ECK/9 ECK/9 ECK/9 ECK7.7.7.7.5.3 1 1 1 1 5 5 5 5 5 5 5 1 Version D C Version D C Version ZMD Version D Version D Version D C DK7/F- DK7/F- DK7 / DK7/F- DK7/F- DK7/F-.7.7.7.7.7.7 3./.1 3./.1 3./.1 3./.1 3./.1 3./.1 5G59/95 5G/9 5G55/95 LAL LFL1.3 with QRA LAL LOA.571 ➃ LOA.171 ➃ LAL -w- 155/ -w- 155/ SQM 1... w 155/3 w 155/3 w 155/3 AE 97 AT 5 AJ E E E galvanised galvanised galvanised galvanised galvanised galvanised x 5 x 5 x 5 x 5 x 5 x 5 13 13 13 1 1 1 5 u. 7 u. 1 7 u. 1 3/ 3/ 3/ 1/ 1/ 1/ EV1B EVB EVB 1..5.5 7 3 55 55 11

Special equipment Item Description L1 L3 No. M1 M3 Order No. Order No. 1 Hours counter in integral switchgear 1 x L Z + T 1 9 1 9 x L Z 1 7 1 7 x M Z 1 7 1 7 Heating for pump E M Z 11 7 11 7 3 Pressure gauge with isolating valve L Z + T 11 3 11 3 RL 1 9 M Z 11 11 Vacuum gauge with isolating valve L Z + T 11 11 RL 11 M Z 11 5 7 11 5 7 5 Potentiometer fitted in servomotor (ZM) RL Ohm 11 RL 1 Ohm 11 3 3 Solenoid valve as additional shut off device ➀ M Z 1 7 1 9 7 Solenoid vlave for post purge L Z without E. 1 5 99 1 5 9 to relieve pressure L Z with E. 1 7 15 1 5 9 L T without E. 1 1 7 7 L T with E 1 7 7 RL 1 5 M Z 1 1 5 Magnetic clutch for post purge L Z without E. 1 3 5 1 1 75 to relieve pressure L Z with E. 1 3 9 1 1 75 L T without E. 1 9 1 5 19 L T with E. 1 5 19 RL without E. 1 1 M Z without E. 1 3 1 3 1 M Z with E. 1 3 91 9 Combustion head extensions L1Z 1 mm 1 3 (for standard execution burners) mm 1 3 3 L1T 1 mm 1 7 mm 1 77 M1Z 1 mm 1 3 3 mm 1 3 31 L3Z 1 mm 1 19 mm 1 1 L3T 1 mm 1 79 mm 1 RL3 1 mm 1 3 mm 1 5 M3Z 1 mm 1 9 mm 1 3 1 Oil meter fitted L1Z 1 5 3 L1T 1 L3Z 1 3 L3T 1 5 7 11 Oil hoses 13 in lieu of 1 mm lang L Z + T 1 3 1 3 1 mm, Gummi, beheizt M Z 1 1 13 mm, Gummi, beheizt M Z 1 3 1 5 1 Burner controller LAL.5 in lieu of LOA.171 L Z Exec. E 1 7 (in combination with LAL.5 in lieu of LOA.171 L Z Exec. D 1 integral switchgear) LAL.5 in lieu of LOA.171 M Z Exec. D 1 5 LOA.5 in lieu of LOA.171➁ L Z Exec. E 1 1 1 1➁ LOA.5 in lieu of LOA.171➁ L Z Exec. D 1 5 1 5➁ LOA.5 in lieu of LOA.171➁ M Z Exec. D 1 5➁ LOK 1 in lieu of LOA resp. LALL Z Exec. E 1 11 1 1 LOK 1 in lieu of LOA resp. LALL Z Exec. D 1 3 9 1 3 99 13 Bunrer controller LAL.5 in lieu of LOA.171 L Z Exec. E + D 1 5 1 5 (loose, for fitting into LOA.5 in lieu of LOA.171L Z Exec. E 1 1 1 1 control panel) LOA.5 in lieu of LOA.171L Z Exec. D 1 5 1 5 LOA.5 in lieu of LOA.171M Z Exec. D 1 5 LOK 1 in lieu of LOA resp. LALL Z Exec. E + D 1 3 1 3 7 LOK 1 in lieu of LOA resp. LALL Z Exec. E-C + D-C 1 3 LOK 1 in lieu of LOA resp. LALRL 1 3 LGK1.3 L3Z-A-1LN 1 5 93 1 Air intake flange RL Exec. ZME 1 3 97 RL Exec. ZMD 1 3 35 15 Intake flange for connection of air duct. 1 7 1 7 1 Type of protection IP5/Industrial version L Z 1 3 19 1 7 L T 1 1 3 RL 1 17 M Z 1 1 3 77 Price reductions 17 Oil preheater EVA in lieu of EVB M Z Exec. D m. E. 1 EVA in lieu of EVB M Z Exec. D o. E. 1 5 EVA in lieu of EVB M Z Exec. D-C m. E. 1 9 1 ➀ The additional price applies only to burners with oil throughputs up to 3 kg/h. For burners > 3 kg/h (version C) this solenoid valve is fitted as standard. ➁ Additional price applies to burners L3Z-A / M3Z-A. Burners supplied to TRD, hr / 7 hr See technical leaflet, print No. 3.

Burner fuel systems Monarch L1Z-B and L3Z-A burners Monarch L1T-B and L3T-A burners Monarch RL3-A sliding two stage and modulating burner without shut off device 1 1 1 1 1 5 13 P M 5a 9 1 a Monarch M1Z-B and M3Z-A burners < 3 kg/h Monarch M1Z-B and M3Z-A burners > 3 kg/h 1 3 1 1 5 3 1 P 7 5a 9 7 1 Pump without inbuilt solenoid valve Pump with two inbuilt solenoid valves 3 Oil preheater Normally closed solenoid valve a Normally open solenoid valve 5 Normally closed solenoid valve (1st shut off device in supply line 115 V, electrically connected in series) 5a Normally closed solenoid valve (1st shut off device in return line 115 V, electrically connected in series - fitted against direction of flow) Normally closed solenoid valve (nd shut off device in supply line 115 V, electrically connected in series) a Normally closed solenoid valve (nd shut off device in return line 115 V, electrically connected in series - fitted against direction of flow) 7 Normally open solenoid valve (stage 1) Normally closed solenoid valve (stage ) 9 Pressure switch in return 1 Oil regulator 11 Nozzle head with one nozzle, without shut off device 1 Nozzle head with two / three nozzles, without shut off device 13 Nozzle head R, without integral shut off device 1 Nozzle head M, with integral shut off device 13

Dimensions Monarch L and M Monarch RL Size 1 and 3 Size 3 Monarch L and M, size 1 and 3 Size Dimensions in mm h1 h h h5 h d1 d d3 d d5 d ➁ b1 b b3 ➀ 1 3 15 9 195 M 135 1 17 1 11/175➀ 1 5/57➀ 153 57/39➀ 3 35 17 35 M1 15 1 13/15➁ 11/175➀ 1/1➁ 59/533➀ 153 31/53➀ b b b7 l1 l l3 l ➁ l5 l l7 r1 r 1 195 1 3 1 195 1 53 555➀ 3 1 7 1 1/13➁ 19 1 5 5/5➀ 75 Monarch RL, Size 3 Size Dimensions in mm h1 h h3 h h d1 d d3 d d5 d b1 b b3 ➀ 3 35 17 15 35 M1 15 1 13/15➁ 11/175➀ 1/1➁ 1/553➀ 153 31/53➀ b b5 b b7 l1 l l3 l l5 l l7 l r1 r 3 35 1 7 1 1/13➁ 19 1 5 5/5➀ 5 ➀ For version E/version D ➁ For combustion head M/1a, M5/a 1

Weishaupt control panels and MCR technology Weishaupt control panels for two stage burners three stage burners sliding two stage burners and modulating burners The basic control panels contain all burner controls, that means all inbuilt switchgear necessary for the operation of a burner. Description Weishaupt control panels conform to applicable national/international standards. Switching includes Power supply Burner control Fan control Start-up/regulation Door mounted switches Door mounted indicating lamps Individual customer requirements can be met at any time. Weishaupt MCR technology for Boiler installations Thermal process equipment Ships execution Building management systems Together with ist core business of burners and heating systems, Weishaupt are able to offer complex control technology up to BMS level with SPS and DDC systems. From planning to handover, tailor made solutions are available from one supplier. 15

Product and customer servicethe complete Weishaupt range Max Weishaupt GmbH, D - 75 Schwendi Tel.: (7353) 3, Fax.: (7353) 335 Print No. 37, July Printed in Germany. All rights reserved. Weishaupt (U.K.) Ltd. Abbey House, 1- Stoke Road, Slough Berkshire SL 5AG Tel.: (1753) 7 5/, Fax.: (1753) 7 7 Weishaupt (U.K.) Ltd. Neachells Lane, Willenhall West Midlands, WV13 3RG Tel. (19) 9 1, Fax (19) 3 33 3 Regular maintenance reduces heating costs and environmental pollution. Only a properly adfusted burner can save enegy end be environmentally friendly. Behind each Weishaupt customer service organisation. The outstanding efforts made in maintenance and service justify the enormous trust places in Weishaupt s burners, for at Weishaupt product and customer service belong together. Weishaupt customer service is there for you all year round. Whenever you need help, be it the supply of spare parts, technical advice or a site visit. We are there when you need us.