Constant Flow Valves. Specifications PVC: 1/2", 3/4", 1", 2", 3", 4" PVC PVC Flanged ANSI EPDM Stainless Steel 304 with ETFE Coating º F

Constant Flow Valves. Specifications Sizes: PVC: 1/2", 3/4", 1", 2", 3", 4" CPVC: 1" and 2" Body: Bonnet: Models: Seals: Springs:

Type 57 Butterfly Valve

Constant Flow Valves ASAHI AV VALVES H-V019-E-6. Contents. Serial No. User s Manual

We believe this modification will benefit you and your customers and apologize for any inconvenience.

RCM - Direct Reading Flowmeters

ATi Max Series. Pressure Independent Control Valves 2 Way 2-1/2-6

INSTALLATION, OPERATION AND MAINTENANCE Threaded and Wafer Style Flowmeters

Pressure Independent Control Valve Applications for Building Automation, Temperature Controls, and HVAC Two-Way Chilled Water Hot Water

Type 375. True Union Ball Valve

introduction RV Series Sediment Strainers Product Data Sheet

DW PADDLE-BELLOWS FLOWMETER & SWITCH

Temperature Regulator I-1285-B through G Series (Bronze Valve Body)

ABB Automation. Variable Area Dial Flow Indicator Series 10A2227. Series 10A2227 Variable Area Dial Flow Indicator

KDM ARMORED FLOW METER & SWITCH

HYDRAULIC CONTROL VALVES

Distributed By Aetna Plastics Pneumatically Actuated Diaphragm Valve DIASTAR Ten and TenPlus General Size: ½ 2 Material: PVC, CP

TEMPERATURE REGULATOR I-1284-P, Q, S, T Series

Diaphragm Valve Type 72

INSTALLATION & SERVICE INSTRUCTION MANUAL W.A. KATES FLOW CONTROLLERS FC VALVE MODELS E THRU M

DW PADDLE-BELLOWS FLOWMETER & SWITCH

Operation and Maintenance Manual

MODEL 106/206-PG POWER OPERATED GLOBE VALVE Sizes 1/2" to 8" (106-PG) 3" to 10" (206-PG) Installation, Operating and Maintenance Instructions

Type 514, 515, 517, 519

NIAGARA. Series WPX. Installation, Operation & Maintenance Manual. Models 210 and 222. Series WPX

TR-QS Wafer-Style Turbine Flow Meters Installation, Operating & Maintenance Manual

RCM. Direct Reading Flowmeter. for Liquids or Gases

Temperature Regulator I-1284-B through G Series (Bronze Valve Body)

Air Operated Valve Control Valve

Lug Style Butterfly Valve Type 578

High Accuracy Mechanical Fuel meter FM-100

introduction FK Series Butterfly Valves Product Data Sheet

Sanitary Design Control Valves V972. Instruction Manual. Installation & Maintenance instructions for W.Arthur Fisher V972 series control valves

Features Globe Valve 2-Way & 3-Way Assembly Features:

MODEL 5540 CONTENTS. Installation, Operation and Maintenance Instructions 1.0 GENERAL

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

Type 145. Electrically Actuated Wafer Butterfly Valve

WCV Series Full Pattern Wafer Check Valves 2 TO 8 PVC AND CVPC

M SERIES Multi-Jet Cold Water Meter

Type 543. Three-way Ball Valve

Product Manual. EX40, Version Last Updated: 11/7/16. Product Description:

Type 567. Wafer Style Butterfly Valve

DK Series Dialock Manual Diaphragm Valves Product Data Sheet

Terminator PICV. Technical Manual

introduction VR Piston Check Valves Product Data Sheet

Sanitary Turbine Flow Meter - TA3 Installation, Operating & Maintenance Manual

FK Series Automated Butterfly Valves Product Data Sheet

ZONE CONTROLE / 2-WAY

Proweld Equipment Owner & Maintenance Manual Miniplast (Widos Shop 4)

FK Series Butterfly Valves Product Data Sheet

Diaphragm Valves Type 15

Installation, Operation and Maintenance Instructions

OMP POSITIVE DISPLACEMENT FLOWMETERS

Positive displacement flowmeter for continuous flow measurement

SC Swing Check Valves Product Data Sheet. Valve Availability. Body Material: Size Range: 3" through 8" Pressure: 100 psi (3") 70 psi (4" to 8")

Installation,Operation and Maintenance Manual H-V016-E-10. Serial No. 目次 ( ページ ) 1. Be sure to read the following warranty clauses of our product 1

NYLON & PVC VALVES MINING DIVISION PRESSURE REDUCING VALVES ENSURE DOWNSTREAM PRESSURE PVC NYLON

Butterfly Valves ASAHI AV VALVES

GATE VALVES. Type P (Standard: Plug) Type S (Soft Seal) Contents. (1) Be sure to read the following warranty clauses of our product 1

Product Manual. S&S V-100 Ball Valves 2 though 8 Inch Designs. Introduction: Installation:

GBV-G Balancing Valves

RUN ACCUM. TOTAL STOP BAT LOW HIGH

Series 8500 Grayline Butterfly Valves

Pneumatic Actuators. Series 79P (Aluminum) Series 79P (Glass-filled Polyamide) Series 79P (316 Stainless Steel)

COMPANY. Pneumatic Flow Meters Installation, Operating & Maintenance Manual AW-Lake Company. All rights reserved. Doc ID:PNEUMAN082516

Model RVL-20. Stainless Steel Low-Pressure Diaphragm Relief Valve

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Toroidal Conductivity Sensor

Swing Check Valve ASAHI AV VALVES. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1

OVAL GEAR FLOWMETER MECHANICAL MODEL 012 (½ )

Diaphragm Valves Type 14 True Union Diaphragm Valves Type14

COOLSAFE Pre-Insulated PE Piping System

OVAL GEAR FLOWMETER MECHANICAL MODEL 075 (3 )

Process Inline Filter PLF1

Technical Data. Series Oval Flowmeter. Model 9400

Check Valves Check Valves are the simplest form of directional control valves, but they can also be used as pressure controls.

WARCO CHEMAG SERIES GH FILTERS

DW PADDLE-BELLOWS FLOWMETER & SWITCH

VORTEX IN-LINE FLOW METERS

Model 1100 Turbine Flow Meter

25 mm (1 in), 38 mm (1-1/2 in) & 50 mm (2 in) TYPE S FLOWMETERS WITH MODEL 157 AND 800 SERIES REGISTERS

Orifice flowmeter F O N4

Serie Ekoflux S. Flanged balancing valve. Application fields. Regulation. Ekoflux.S_GB_22/04/2015 HEATING CONDITIONING

Flow Control. Before installation or maintenance, these instructions must be fully read and understood.

EMP1 OPERATING & INSTALLATION INSTRUCTIONS

Daniel. Liquid Control Valves Technical Guide. Technical Guide DAN-LIQ-TG-44-rev0813. DAN-LIQ-TG-44-rev0208. February 2008.

BYPASS ROTAMETERS FOR MEASURING RATE OF FLOW IN LARGE PIPELINES

Orifice Flange Union Assembly and Orifice Run Installation and Operation Manual

PS AMA F (a) 0411 ( )

Vortex In Line Flow Meter

50-01 (Full Internal Port) (Reduced Internal Port) Pressure Relief. & Pressure Sustaining Valve MODEL

2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50

Type 2712 (8630) Continuous TopControl System. General data Compatibility Materials of wetted parts Body Rotor Shaft Seal

SIGNET 7002 Vortex Flow Sensor ENGLISH

HAYWARD FLOW CONTROL TBH SERIES TRUE UNION BALL VALVE INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Technical Data SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 1520 SERIES 2000 DIRECT & REVERSE ACTING

Type Electrically Actuated Ball Valve

Filters & Strainers Technical Information TECHNICAL INFORMATION WEIGHTS & DIMENSIONS

Moniteur INSTALLATION & OPERATING INSTRUCTIONS. SERIES 40 Positioners. Installation and Operating Instructions Series 40 Positioners.

ASAHI/AMERICA High Purity Gooseneck Distribution Faucets

Transcription:

Sizes: Body: Bonnet: Models: Seals: s: Temperature: Specifications : ", ", 1", 2", 3", 4" Flanged ANSI EPDM Stainless Steel 304 with PCTFE Coating 30 1º F Constant Flow Valves Standard Features (Sizes " 4") Body and bonnet are of solid All wetted parts are of thermoplastic and elastomeric materials for superior corrosion resistance A preset constant flow rate is maintained by automatically regulating orifice opening area, responding to changes of pressure differentials across the valve see "Principles of Operation " on the following page Vertical or horizontal installations Flow rate accuracy: plus or minus 6 % of full scale flow rate (water at ambient temperature) Flow rate rangeability: : 1 maximum Hand wheel permits ON/OFF opening and closing Hand wheel serves as a mechanism by which the flow rate setting may be adjusted without shutting down the pipeline s of Stainless Steel 304 with PCTFE coating tested for long cycle life Prescribed flow setting is clearly visible on the indicator at the top Sample Specification All constant flow valves shall be of solid thermoplastic-flanged construction, and all wetted parts shall be of non-metallic materials. Size " and " shall be of inline design, while 1" - 4" shall be a Y type design. shall conform to ASTM D84 Cell Classification 14-A. construction shall be 304 SS with PCTFE coating. All constant flow valves shall have a calibrated flow dial and position indicator. Valve accuracy shall be +/- 6% of full scale. Constant flow valve sizes "- 3" shall have a maximum upstream pressure range of 0 psi at 1 degree F. and Size 4" 70 psi at 1 degree F as manufactured by Asahi/America, Inc. TYPE S A B 1", 2" 3" ", ", 1", 2", 3", D 3", 4" CHARACTERISTICS Fluid flows through the valve Flow rate setting range is large (small to large flow rate) Lines with large pressure differ re eam) High flow rate TYPE A (1" 3") TYPE B (" TYPE C (" 4") TYPE D (3" P1 P2 P2 P1 FLOW FLOW 3 Green Street, P.O. Box 63, Malden, MA 048 Tel: 800-343-36 781-3-409 Fax: 800-426-708 E-mail: asahi@asahi-america.com Register at our interactive web site for on line ordering, product availability, order tracking, and many useful features: www.asahi-america.com 1

" " Model 3 8 2 6 7 1 9 ød2 W L Principles of Operation t ød C P.C.D. 4 ød n- øh H 2 H1 H 1. When the upstream fluid pressure, P1, is introduced at the flow control orifice, it exerts a responding pressure on the upper surface of the flange on the piston type valve plug. 2. Likewise, the downstream pressure, P2, exerts a corresponding pressure to the lower surface of the valve plug flange. 3. Thus, when a differential exists between the fluid upstream and downstream of the orifice, the corresponding differential pressure acting on the surfaces of the flange moves the valve plug piston either downward against the force of the spring cartridge or upward by the force of the spring, depending upon the direction of the force induced by the existing differential pressure. 4. This upward or downward movement of the valve plug piston causes the flow orfice to be widened or narrowed accordingly, thus the flow rate of the fluid passing across the orifice is automatically adjusted. For example, if the differential pressure, (P1 P2) created between the upstream and downstream sides of the orifice increases, the valve plug piston moves downward to narrow the area of the orifice opening and automatically adjusts to the preset flow rate value. The reverse is also true when the differential pressure decreases, piston moves upward increasing the orifice opening area and allowing the fluid flow rate to increase to the preset value. Parts List (Sizes " ") NO. PARTS D ESCRIPTION PCS. MATERIAL 1 Body 2 Bonnet 3 Cylinder 4 Piston Plug 6 Orifice 7 Seat 8 Cap Nut 9 Cap Stop 1 PVDF Sleeve Nut (C) (D) Key 2 PP Thrust Handle Handle Cover Screw 4 Stainless Steel 304 * With PCTFE coating Dimensions (Sizes " ") 0 W D2 H H1 H 1 3. X 3. 4.06 7.76.08 2.01 2 3. X 3. 4.06 7.76.00 2.09 mm 0 ANSI CLASS 0 m m d D c n h L t 1 0.63 3. 2.38 0.47 2 0.79 3.88 2.7 0.1 NOTE: THE PISTON FOR TYPE B, C AND D DOES NOT HAVE INLET FLUID PASSAGE. THE PRESSURE DIFFERENTIAL, (P1 P2), EXERTS DIRECTLY ON THE PLUG SURFACE. 2 ASAHI/AMERICA Rev. F 8-

Parts List (Sizes 1" 4") PARTS Preset Flow Rates (AND WORKING DIFFERENTIAL PRESSURE) 2 4 0 TYPE 1" 4" Model FLOW RATE RANGEABILITY WORKING DIFFERENTIAL PRESSURE m m GAL./MIN. PSI B 0.6 3.2 C 0.3 3.2 B 0.26.28 C 0.3.28 A 2. B 0.441 C 0.881 A 8.81 3. B 1.76 3. C 3.2 3. A.02 1 4.8. B 4.403 C 8.81 D 66.04 2. 2: 1 4.27.33 C 44.03 264. 6: D 2. 264. 2: 1 2.8.33 NO. D ESCRIPTION PCS. MATERIAL 1 Body 2 Bonnet 3 Cylinder 4 Piston Plug 6 7 Stop 1 PVDF 8 Orifice 9 Seat (C) Sleeve Cap Key Thrust Washer Washer 2 Hand Wheel Screw Lift Indicator (D) Weight (POUNDS) mm FLANGED 2.02.74 4 0 36.38 * With PCTFE coating 3 Green Street, P.O. Box 63, Malden, MA 048 Tel: 800-343-36 781-3-409 Fax: 800-426-708 E-mail: asahi@asahi-america.com 3 Register at our interactive web site for on line ordering, product availability, order tracking, and many useful features: www.asahi-america.com

Dimensions (Sizes 1" 4") ANSI CLASS 0 m m d D C n h I1 I2 L t A B H E Degree 0.98 4.2 3. 1.7 4.72 0..71 7.91 8.8.91 2 2.0 6.00 4.7 4 0.7 2. 6.89 9.06 0.79.3..09 3.07 7. 6.00 4 0.7 2.76.02 0.87.06..84 ANSI CLASS 0 m m d D C n h I1 I2 L t A B H E Degree 1 3.94 8.66 7. 8 0.7 3.3.40.7 0.87.3.02.6 9.84 4 00 Caution Constant Flow valves are intended for Clean Fluid services. Should the possibility of foreign matters exist in the media, a sediment strainer of 60 mesh is to be installed in the upstream of the valve. For added protection, avoid installing valves with bonnet facing downward, regardless of vertical or horizontal installation. For the utmost functional accuracy, the following conditions apply: 1. Media specific gravity: Sizes " - 3" up to 1.4, Sizes 4" up to 1.1 2. Media viscosity: maximum 30 cp 3. Working pressures are grouped into 4 that correlate to working temperatures per the format below. For size 4", maximum upstream working pressure is 70 psi. Make sure of the Flow Direction is clearly marked on the valve body before installation. Note that flow direction of Type A is different from that of Type B, C and D. The valve can be installed either vertically or horizontally, as long as fluid always fills the valve fluid passage. Tips On Constant Flow Valve Keep constant flow rate without power or labor. To operate, simply rotate handle clockwise to bring indicator to the designated position. Rotate handle clockwise to decrease the flow and counter-clockwise to increase. To fully close the valve, rotate handle clockwise to bring the indicator to 0 (zero) position. To properly set a new flow rate, rotate handle counter-clockwise till the indicator goes beyond the intended new rate. Then, reverse (rotate clockwise) to the new rate. Indicator must be positioned at 0 (zero) of the gauge, if bonnet is to be disassembled. The valves are ideal for: 1. Any constant media supply 2. Well-balanced fluid supply in parallel piping systems 3. Simultaneous and even fluid supply to multi-pipelines, multi- tanks, large and small pools 4. Cooling towers and scrubbers, etc. Never operate the valves when indicator is out of the gauge range. Never attempt to disassemble indicator unit at the top (preset by the factory). Never remove valve from pipeline under pressure. Always wear protective gloves and goggles. 4 ASAHI/AMERICA Rev. F 8-

Available Upstream Pressure Range (Size " - 4", Type-A,B,C,D) BODY MATERIAL TEMPERATURE UPSTREAM PRESSURE RANGE 0-3 PSI 3-70 PSI 70-1 PSI 1-0 PSI 3-8 F 86 - F 6-1 F Max. Allowable Upstream Pressure " - 3"; 0-0 PSI 4"; 0-70 PSI Troubleshooting What if fluid flows even when valve is fully closed? 1. Either seat or plug is damaged. Replace body or cylinder. 2. Foreign material caught between plug and orifice. Clean seat and plug. What if valve cannot be closed? 1. Foreign material trapped or built up between plug and orifice. Disassemble and clean. What if fluid leaks outside? 1. O-ring is chemically attacked or damaged. Replace O-ring. What if flow is extraordinarily small? 1. Insufficient differential pressure. Adjust differential pressure. 2. Foreign material caught between plug and orifice. Clean. What if flow rate exceeds the preset range? 1. Differential pressure exceeded the range. Adjust differential pressure. 2. Damaged or worn plug and/or orifice. Consult factory. 3. Foreign material caught between plug and orifice. Constant Flow Valves Ordering Information Service Conditions 1. Media: Conc: % 2. Specific Gravity Viscosity 3. Line Temperature:Max. ( F) Line Temperature:Min. ( F) 4. Flow Req'd: Max (gpm) Min (gpm). Max Line Pressure:Upstream (psi) Downstream (psi) 6. Min Line Pressure:Upstream (psi) Downstream (psi) Valve Specifications 1. Line Size: 2. Type: 3. Temp. Range: 4. Pres. Range:. Seal Material: 6. Connection: NOTE: CONSTANT FLOW VALVES ARE SPECIAL ORDERED FROM JAPAN AND CAN NOT BE ORDERED WITHOUT CUSTOMER PROVIDED SERVICE CONDITONS 3 Green Street, P.O. Box 63, Malden, MA 048 Tel: 800-343-36 781-3-409 Fax: 800-426-708 E-mail: asahi@asahi-america.com Register at our interactive web site for on line ordering, product availability, order tracking, and many useful features: www.asahi-america.com