Continental Super Flow

Similar documents
INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

PPM EO-100 TM. Operation Manual

Manufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1

STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications

SMPT OSA1 / 4. VISAGAGE ORIFICE SELECTOR Patent #9,433,144

A1100 GUARDIAN OVERFILL PREVENTION SYSTEM

12 Volt Utility Controller for 4, 6 or 8 Brakes No P

Installation & Operation Manual. Electrak 100 Series / Electromechanical Linear Actuator

AccuFlow Vortex Installation Manual: John Deere 2510 H. P/N Rev. B 03/17 E29018

PARTS AND INSTALLATION MANUAL

Dual Phase Extraction Inlet. Patent No Installation Manual. P/N Rev

TRI-GRAIN MOISTURE TESTER OVVNER'S MANUAL

TBHD1 CRIMPING TOOL FOR THOMAS & BETTS TS DIES

Installation and Maintenance Instructions 44TA Liquid Level Float Switch

Wrap Spring Clutches & Brakes CB & Super CB Series P-2026-WE SM592-gb-02/08

Installation & Operation Manual. Electrak 1 Series / Electromechanical Linear Actuators Limit Switch, & Potentiometer Feedback, and Long Life Models

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type

Low Pressure Fluid Filters

A Member of the. Integrated Metering Technologies

2017 Price List 2018 Price List

PLEASE ENSURE THE JUMP STARTER IS FULLY CHARGED PRIOR TO FIRST USE.

Lubricator Gun: 10,000 psi (700 bar) Maximum Delivery Pressure when disconnected from Dispenser

Grinnell Grooved Fire Protection Products Grooved Fittings

Model For petroleum products and other fluids compatible with aluminum and buna-n seals.

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

ASM Maxi Poles. Instruction-Parts B Series. For the application of architectural paints and coatings.

390 Airless Sprayer. Parts J EN. Models: , , , , , ,262024, , , , Hi-Boy.

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Utility Controller Hand Air Operated

CBC-160-1N and CBC-160-2N Clutch/Brake Controls

WATERBLAST HOSE REEL SYSTEM HWB HOSE REEL OPERATION AND MAINTENANCE MANUAL W A T E R J E T T O O L S

Instruction Manual for Globe Price Computing Scale Models GS30 and GS30T

DP DIAPHRAGM PUMP Parts & Instruction Manual

Electromagnetic Particle Clutches and Brakes Models: POC, PHC-R, PMC-A3, POB, PRB and PTB-BL3 P Performance Manual

DeZURIK 2 20" BOS BUTTERFLY VALVES

Installation Guide Document N Cleanroom Mirrors Copyright 2016 Terra Universal Inc. All rights reserved. Revised November 2016

SOLAR DASH CHARGING SYSTEM USER GUIDE

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

TERMS OF USE TERMS AND CONDITIONS. Plumbing and Heating Products (PL-WR)

MODEL 1385 & 1385-H Professional Rotary Drum Pump

3M Housings CH Series

INSTRUCTIONS PARTS LIST This manual contains important warnings and information. READ AND RETAIN FOR REFERENCE

TANK MONITOR SYSTEMS DTM04 TANK MONITOR DTM08 TANK MONITOR DTM12 TANK MONITOR INSTALLATION AND OPERATION MANUAL

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

PowerMax Diesel Upgrade For Cummins Engines

Preassembled Clutch/Electrically Released Brake Module

Installation Instructions / Warranty. Citterio 39115XX1

PFS Rotameter. Variable Area Flowmeter. Instruction Manual PFS-RM200, RM230, RM250

PowerMax Diesel Upgrade For Cummins Engines

SERIES 300V 115 and 230 VOLT AC FUEL TRANSFER PUMP Owner's Operation & Safety Manual Models FR300V, FR301V, FR310V & FR311V

StormPro BA Series Sump Pump

Operating and Installation Instructions

Owner s Manual Nitrate Series Salt Based Filter System

MetroPrime 22MPC Self-Priming Centrifugal Pump

V400D VERIS Verabar (Double Rod) Installation and Maintenance Manual

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

Warner Electric UNIBRAKE Motor Brakes

FR1118- P10. User s Manual

MTB II Modular Tension Brakes

300 Series INSTRUCTION MANUAL. Compressed Air Filters Models 302 (grade) through 317 (grade)

Extreme Duty Grapple (Rock, Skeleton, Scrap & Tine) Operation and Maintenance Manual

Model:M5B/M5W/M5N. Installation Guide. Specifications Desktop Weight Capacity Keyboard Tray Weight Capacity Height Adjustable Range

Instruction Manual for Globe Price Computing Scale Models GS30 and GS30T

DISCONTINUED VERSION Parts listed in this catalog may no longer be available. ILLUSTRATED PARTS CATALOG

REDI-LINE. Rugged, Reliable, DC to AC Power Conversion ELECTRIC GENERATORS USER'S GUIDE. KARAM A.L.

Pneumatic Cylinder 14 Bore X 21 Stroke Part No. P Replaces Part No. P

Ultimate Mx II. Parts List E psi (228 bar, 22.8 MPa) Maximum Working Pressure. Vac Model Type Lo-Boy Hi-Boy. Sherwin Williams 120V

Installation Instructions

Safety Sentry Electronic Breakaway Switch

OWNERS MANUAL HF4550 PREACHER CURL. Customer Service (800) (858) Fax (858) RECORD SERIAL NUMBER HERE

INSTALLATION AND OPERATION MANUAL

12 Volt Utility Controller for 4, 6, or 8 Brakes No

Model GX Spray Gun

Stainless Steel Air Motor Conversion Kits

Fuel Meter. Instructions - Parts List. Contents B. Model , measures in gallons Model , measures in liters. For metering fuels.

OWNERS MANUAL HF PAIR VERTICAL DUMBBELL RACK. Customer Service (800) (858) Fax (858) RECORD SERIAL NUMBER HERE

OWNERS MANUAL HF

Instruction Sheet DWRSR-ZL. Zero Clearance Latch

BUG PREP KIT 2.0 HAND-PREP SYSTEM. User Manual REV A reva0616

Gen 2 Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB

AUTOMATION. Operator s Manual. NLS Series. Pneumatic Level Sensors. Rev. A1, 4/07

Gooseneck Hitch Ball plate with 2-5/16" ball spins in/out 30,000 lb. rating. (5,000 lb. vertical load) Requires only one 3" hole in truck bed

Pneumatic Cylinder 14 Bore X 22 Stroke Part No. R (Formerly P )

TITAN FLOW CONTROL, INC.

Pressurized oil drain for collection of used lubricants and anti-freeze.

900 SERIES SPLIT CASE FIRE PUMP REPAIR PARTS INDEX

Compressor Clutch Replacement Procedure

MM10 Dual Cartridge Dispenser 1:1 & 2:1 A Style Cartridges MM10 Dual Cartridge Dispenser 1:1 & 2:1 B Style Cartridges

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

CDS-JOHN BLUE COMPANY

1. Contents 1. CONTENTS INTRODUCTION SAFETY WARNINGS POWER TILT STANDARD OPERATING INSTRUCTIONS... 5.

EAGL 1-Touch Laser Level

MAINTENANCE NOTE: ANY LEAK FROM THE MAIN BODY OF THE LOAD IS AN INDICATION THAT THE UNIT SHOULD BE RETURNED TO THE FACTORY FOR REPAIRS.

Motorized Tempering Valves with Transformers for

INVERTER HARNESS INSTALLATION FOR FREIGHTLINER CASCADIA

VSP SERIES Installation, Operation and Maintenance Manual

ml Dual Cartridge Dispenser 10:1 B Style Cartridge ml Dual Cartridge Dispenser 1:1 & 2:1 B Style Cartridge

Installation Instructions SRC Over-Size Tire Carrier Jeep Wrangler/Unlimited Part # 2743

Pump Package Conversion Kits

Transcription:

WARNING Refer to Material Safety Data Sheets (MSDS) and other pertinent safety requirements associated with the handling and application of anhydrous ammonia with a local anhydrous ammonia supplier. It is recommended that users also consult other helpful sources concerning proper procedures for handling anhydrous ammonia and related equipment use, e.g., The National Ag Safety Database (www.cdc.gov/nasd) and The Fertilizer Institute, 1015 18th Street, NW, Washington, DC 20036. For your own protection, it is important to carefully read, understand, and follow all safety precautions when handling anhydrous ammonia. Anhydrous ammonia can be very dangerous if improperly handled. All safety procedures must be carefully observed. Serious injury is preventable when safety precautions are observed. These safety precautions are not meant as a substitute for proper training regarding the handling and application of anhydrous ammonia. Do not use or handle anhydrous ammonia without appropriate training. 1

IMPORTANT: Valves and other component parts do fail from time to time according to their useful life. Please inspect and replace component parts pursuant to manufacturer s guidelines. If component useful life is not included in a manufacturer s guidelines, please consult with the component manufacturer. 2

Contact Continental NH3 Products for Super Flow Assembly usage guidelines: 130 Yorktown Dallas, TX 75222 PH#1-800-537-5642 www.continentalnh3.com The Super Flow Assembly is a manufactured product of Continental NH3 Products, therefore, the user should consult with the individual manufacturer s guidelines regarding inspection, maintenance, and useful life of any component parts. DICKEY-john does not warrant products that are not manufactured by DICKEY-john and does not make any definitive representation regarding the useful lives of those parts. It is recommended to conduct daily inspections of hoses for kinks and defects, as well as full inspection and maintenance of those hoses and valves. IMPORTANT: A thread sealant that is compatible with anhydrous ammonia MUST be used. Do not use Teflon tape. 1. Install sweep elbow on mounting plate. 2. Sweep elbow/mounting plate assembly. 3

3. Install Super Flow on top of sweep elbow assembly. 7. Thread fl ow meter fl ange on 1 1/4 pipe nipple. The cut recess should face upwards to accept the fl ow meter fl ange gasket. 4. Install 1 1/4 x 4 pipe nipple into sweep elbow. 8. Place gasket in recess groove. 5. Thread 1 1/4 pipe elbow on the end of the 1 1/4 pipe nipple. 9. Place remaining fl ow meter fl ange recess-side down. 6. Install 1 1/4 x 4 pipe nipple into top of elbow. 10. Install 1 1/4 x 4 pipe nipple into fl ow meter fl ange. 4

11. Install 1 1/4 control valve onto pipe nipple. 15. Install valve actuator bracket to valve using bolts and lock washers provided. 16. Carefully place fl ow meter into fl ange. Ensure that the fl ange gasket remains seated into recess of the fl ange. 12. Locate 2 coupling bars and 2 coupling screws. 13. Install coupling bars onto valve using the 2 coupling screws with the pins facing outward. 17. IMPORTANT: The word OUT must be facing up when placing the fl ow meter into the fl ange. Record the fl ow meter calibration numbers found on the fl ow meter and record in the owner s manual for future reference. Place a gasket on the top of the fl ow meter. 14. Install vapor charge elbow onto valve with hose barb pointing up. 18. Place completed valve/fl ange assembly onto fl ow meter. Ensure that the gasket remains seated into fl ange recess. 5

19. Align holes in fl anges and place 3 fl ange bolts through both fl anges. 22. Orient valve actuator so that the pins insert into the remaining 2 holes on valve coupler. Place 4 bolts on bottom of valve actuator through valve bracket. 20. Secure and tighten fl ange bolts using nuts and lockwashers provided. 23. Secure valve actuator to bracket using the 4 nuts and lock washers provided. 24. Completed assembly. 21. Place black valve coupler onto pins on valve. 6

25. Thread a 1 1/4 x 4 nipple into input port on unit. 28. Insert the (4) 3/4 hose barbs into holes provided in bottom ring of unit. 26. Thread 1 1/4 Y strainer onto nipple. Arrow on Y strainer must be facing the unit. Also, install the 3/4 drain plug in the bottom of the Y strainer. 29. Note the letter stamped into the hose barb on the vapor charge adapter. 27. Install the straight hose barb into the 1/4 bung below the main inlet. This hose barb does not have an orifi ce like the barbs that are installed in the vapor charge adapter. 30. Refer to the fl ow chart in the Super Flow manual and install the appropriate hose barb into the vapor charge elbow. 31. Install the EVA tubing from the hose barb on the vapor charge adapter to the hose barb on the lower portion of the unit that was installed in step 27. Secure with clips or hose clamp. 7

Part Identifi cation NH Tubing 3/8" 3 Hose Barb 1 1/4" to 1" Elbow Vapor Charge Adaptor Valve *Vent hole side of valve Actuator 11/4"x4" Flange Flowmeter Y Strainer Vapor Dump Hose Barb Flange Hose Barb 11/4"x4" Nipple 11/4"x4" Nipple 1 1/4" to 1 1/4" Elbow 8

Dealers have the responsibility of calling to the attention of their customers the following warranty prior to acceptance of an order from their customer for any DICKEY-john product. DICKEY-john WARRANTY DICKEY-john warrants to the original purchaser for use that, if any part of the product proves to be defective in material or workmanship within one year from date of original installation, and is returned to DICKEY-john within 30 days after such defect is discovered, DICKEY-john will (at our option) either replace or repair said part. This warranty does not apply to damage resulting from misuse, neglect, accident, or improper installation or maintenance; any expenses or liability for repairs made by outside parties without DICKEY-john s written consent; damage to any associated equipment; or lost profits or special damages. Said part will not be considered defective if it substantially fulfills the performance expectations. THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES OF MERCHANTABILITY, FITNESS FOR PURPOSE, AND OF ANY OTHER TYPE, WHETHER EXPRESS OR IMPLIED. DICKEY-john neither assumes nor authorizes anyone to assume for it any other obligation or liability in connection with said part and will not be liable for consequential damages. Purchaser accepts these terms and warranty limitations unless the product is returned within fifteen days for full refund of purchase price. For DICKEY- john Service Department, call 1-800-637-3302 in either the U.S.A. or Canada Headquarters: 5200 Dickey-john Road, Auburn, IL USA 62615 TEL: 217 438 3371, FAX: 217 438 6012, WEB: www.dickey-john.com Europe: DICKEY-john Europe S.A.S, 165, boulevard de Valmy, 92706 Colombes France TEL: 33 (0) 1 41 19 21 80, FAX: 33 (0) 1 47 86 00 07 WEB: www.dickey-john.eu Copyright 2008 DICKEY-john Corporation Specifications subject to change without notice.