Ultimate Low Flow Coriolis Mass Flowmeter

Similar documents
RHM 04 - Universal Coriolis Mass Flowmeter with particular Fast Response

RHM 12 - Standard 1 inch Coriolis Mass Flowmeter

RHM 015. Ultimate Low Flow Coriolis Mass Flowmeter. Applications. Features. Advantages

RHM 04. Universal Coriolis Mass Flowmeter with particular Fast Response. Applications. Features. Advantages

RHM 03. Flexible Coriolis Mass Flowmeter for low flow measurements. Applications. Features. Advantages

RHM 08. One of the most popular Rheonik Mass Flowmeter serving thousands of worldwide applications. Applications. Advantages.

RHM 06. One of the Most Popular Rheonik Mass Flowmeter Serving Thousands of Worldwide Applications. Applications. Advantages.

Coriolis Mass Flowmeter for low flow measurements

RHM 80 - Coriolis Mass Flowmeter for large flow applications optional heavy duty version

RHM The world s largest Coriolis Mass Flowmeter for flow rates up to kg/min

RHM Coriolis Mass Flowmeter for high Flow Applications

RHM 60. Coriolis Mass Flowmeter for Medium Flow also Suited for High Pressure Applications. Applications. Advantages. Features

RHM 03 a1 - (low stress in welds and increased wall thickness against abrasion) RHM bar APPLICATIONS. Batching Dosing. Injections Filling

RHM015. Ultimate Performance Coriolis Mass Flow Meter for Critical Ultra Low Flow Applications. Features. Applications. Benefits

RHM08. Versatile Coriolis Mass Flow Meter. Features. Applications. Benefits

RHM04. Compact Coriolis Flow Sensor With Enhanced Performance. Features. Applications. Benefits

RHM30. Coriolis Mass Flow Meter for Plant and Loading Flows. Features. Applications. Benefits

RHM40. Coriolis Mass Flow Meter for Demanding Applications. Features. Applications. Benefits

RHM 015L/02L/03L/04L. Compact Low Flow Coriolis Flow Sensors

RHM 015L/02L/03L/04L. Compact Low Flow Coriolis Flow Sensors

Micro Motion Model D and DL Coriolis Flow and Density Meters

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel

Micro Motion F-Series Coriolis Flow and Density Meters

Rheonik Coriolis Mass Flow Meters

Options guide. Electromagnetic flowmeters. M9xx

OPTIMASS 3000 Technical Datasheet

Flow Measurement SITRANS F M. Flow sensor MAG /85. Overview

SITRANS F flowmeters SITRANS F C

Micro Motion T-Series Straight-Tube Mass Flow and Density Meters. Product Data Sheet PS July 2001

LIQUID CONTROLS A Unit of IDEX Corporation

SITRANS F flowmeters SITRANS F C SITRANS F C MC2 4/169. Overview

SITRANS F flowmeters SITRANS F C MASSFLO MASS MC1. 4/146 Siemens FI Overview

Flow Measurement SITRANS F C. Flow sensor MASS 2100 DI 3 to DI 40. 4/180 Siemens FI

VersaFlow Coriolis 100 Mass Flow Sensor Specifications

Flow Measurement SITRANS F M. Flow sensor MAG 1100 F 4/57

Micro Motion ELITE Coriolis Flow and Density Meters

SITRANS F C. Flow sensor MC2 4/193. Overview

Product Data Sheet PS February Model D and DT. Mass Flow and Density Sensors.

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet

SITRANS F M. Flow sensor MAG 1100 F 3/59

Food & beverage. Oil & gas. Water & waste water

Flow Measurement SITRANS F C

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T

Flow Measurement SITRANS F C

OPTIMASS 2000 Technical Datasheet

Micro Motion ELITE High Capacity Coriolis Flow and Density Meters

Flow Measurement SITRANS F M

Micro Motion F-Series Coriolis Flow and Density Meters

Differential Pressure Gauges (701P Series)

Metal tube variable area flowmeter for gases, liquids and steam

KROHNE 10/ Optimass 70 & 71 Single Tube Coriolis Mass Flowmeters for the Chemical Industry

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

KROHNE 10/ Optimass 70 & 71 Single Tube Coriolis Mass Flowmeters for the Pharmaceutical Industry

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Level Probes multicap T DC 12 TE multicap T DC 11/16/21/26 TEN/TES

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

OPTIGAS 4010C Technical Datasheet

OPTIFLUX 6000 Technical Datasheet

KROHNE 10/ Optimass 70 & 71 Single Tube Coriolis Mass Flowmeters for Food & Beverage Processing

MASSMAX 1000 Series Straight twin tube Coriolis Mass Flowmeter

Level Measurement Point level measurement - RF Capacitance switches

Flow Measurement SITRANS F C

VersaFlow Vortex 100 Vortex Flow Meter Specifications

OPTIGAS 4010C Technical Datasheet

Micro Motion ELITE High Capacity Coriolis Flow and Density Meters

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

Magnetic-inductive flow meter for hazardous areas

Applications. T h e C o r i o l i s E x p e r t s

Coriolis Flow Solutions for a Global Marketplace

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

OM004, OM006 & OM008 Oval Gear Meter

Coriolis Mass Flow Measuring System promass 64

OPTISWITCH 4000/5000. Vibration level switches for liquids

SITRANS FC. Flowmeter SITRANS FC410

Technical Data Sheet PS , Rev C May Micro Motion R-Series Coriolis Flow and Density Meters

Coriolis Flow Solutions for a Global Marketplace

Micro Motion Model CNG050 Compressed Natural Gas Flowmeters

Micro Motion F-Series Flow and Density Meters

Flow Measurement SITRANS F M

Armstrong In-Line and Insertion Vortex Flow Meters

Micro Motion 7827 Digital Viscosity Meter

SITRANS F C MASSFLO Practical examples of ordering. MASS2100 & MASS6000 IP67 Compact mounted

Micro Motion ELITE Mass Flow and Density Meters

Operating Instructions. VEGASWING 61, 63 with oscillator SW E60N (EX)

Flow Measurement SITRANS F C

Coriolis Flowmeters. Coriolis Flowmeters. KCM C-flow series Coriolis mass flowmeter

SITRANS F M flow sensors 711/A and 711/911E

Micro Motion T-Series Coriolis Flow and Density Meters

TORRIX Magnetostrictive level sensor

Technical Offer. ViscoPro Measure Viscosity and Temperature on line for continuous process improvement

Multivariable Vortex Flow Meter

COVOL. Operating Data. Areas of Application. Measuring Ranges. Method of Operation. Fields of operation. Features. Installation information

Micro Motion Model CNG050 Compressed Natural Gas Flowmeters

Flowmeters. The Satam flowmeter range is used for the custody transfer measurement of liquid hydrocarbons, liquid gas and liquid chemicals.

Flow Measurement SITRANS F M. Flow sensor MAG 5100 W. 4/68 Siemens FI Overview

TURCK DC Insertion Flow Monitors

Promass Q for the process industry

EGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

JUMO dtrans p20 DELTA

Transcription:

RHM 015 - Ultimate Low Flow Coriolis Mass Flowmeter The RHM 015 can reliably measure flow rates as low as 1 g/min (0.002 lb/min). With its extremely wide turn-down ratio of 300 to 1, this model is perfect for laboratory and test applications. A true low flow mass flowmeter manufactured by Rheonik, the mass flowmeter experts. APPLICATIONS Suitable for virtually any mass flow application such as: General flow control Dosing Batching Injections Filling FEATURES The outstanding features include: Suitable for pressures up to 868 bar Typical measuring ranges from 0.004 kg/min to 0.6 kg/min Minimal flows as low as 0.0015 kg/min Available as single pipe system for sanitary applications / CIP suitable Flow Accuracy of 0.10% Repeatability better than 0.05% Extra compact design with minimal space requirement EEx Approvals (i.e. ATEX, CSA,...) Custody Transfer Approvals (i.e. PTB, NMI...) GENERAL The RHM 015 has been in production for many years and is available in a wide range of varying models. The meter has been optimized for applications which have extremely low flow rates. As with all other Rheonik meters, this model is based on the patented Omega tube design with increased signal to noise ratio. This unique design, which offers excellent performance and reliability, has created the most satisfied customers worldwide. Unlike other mass flowmeter manufacturers, Rheonik uses a patented torsion rod swinger with the Omega shape and support bars which results in high accuracy measurement, which is independent of pressure, even at very low flow velocities. The meter has also extremely good repeatability and high stability for critical applications. ADVANTAGES No pressure effect no deterioration of accuracy due to pressure changes by the patented Omega Shape Better performance than thermal meter Patented torsion swinger design assures longest life time and increased safety (low stress in welds and increased wall thickness against abrasion) No moving parts practically no maintenance Removable connection block M015 Page 1 of 7 / 18 November 2005 - v5

PERFORMANCE RHM 015 Max Flow 0.6 kg/min (1.32 lb/min) 1) Standard Models Rates / turndown ratio in kg/min in lb/min error in % of reading nominal rate Qnom 0.600 1.323 0.15 0.2 * Qmax (5:1) 0.120 0.265 0.20 0.1 * Qmax (10:1) 0.060 0.132 0.20 0.05 * Qmax (20:1) 0.030 0.066 0.20 0.0125 * Qmax (80:1) 0.008 0.017 0.50 Typical P in bar (psi) 1 cp 100 cp 1.9 (26) 54.6 (792) 0.1 (1.6) 10.9 (159) ~ 0 (0.8) 5.5 (79.1) ~ 0 (0.4) 2.8 (39.9) ~ 0 (0) 0.7 (10.5) 2) Optimized Low Flow Models (*) / optimized to be operated between 0.5 x Q max and 0.005 x Q max 0.5 * Qmax (1:1) 0.300 0.661 0.15 0.01 * Qmax (50:1) 0.006 0.008 0.30 0.005 * Qmax (100:1) 0.003 0.004 ~ 0.75 (**) 0.5 (7.9) 27.3 (395) ~ 0 (0) 0.5 (7.9) ~ 0 (0) 0.3 (3.9) (*) serial/single path version offers the same accuracy at half the flow (Qmax = 0.3 kg/min) (**) around 0.50-1 % accuracy depending on the installation conditions 3) Gold Line Models / application fine tuned meters 1 * Qnom (1:1) 0.600 1.323 0.10 0.1 * Qnom (10:1) 0.060 0.132 0.10 0.05 * Qnom (20:1) 0.030 0.066 0.12 1.9 (26.9) 54.6 (792) ~ 0 (0.8) 5.5 (79.1) ~ 0 (0.4) 2.8 (39.9) Repeatability Temperature better ± 0.05 % of rate better ± 1 C Standard Models Gold Line Models Error (%) 1,5 P (bar) Error (%) P (bar) 2,0 1,5 2,0 1 1 0,5 0,5 0 1,0 0 1,0-0,5-0,5-1 -1-1,5 0,0 0 0,2 0,4 0,6 Flow rate (kg/min) -1,5 0,0 0 0,2 0,4 0,6 Flow rate (kg/min) For serial (single pipe/path) sanitary design Qmax is 0.3 kg/min (50%). Data above refer to standard wall thickness. Error of reading (including zero drift) indications refer to reference conditions H 2 O, 18-24 C (66-76 F), 1-3 bar (15-45 psi). RHM sensor do not suffer from pressure effect due to torsional oscillation and semi circle (non-deforming) measurement section. Temperature changes of +/- 25 C around the operating point are negligible. Pressure drop refers to Newton liquids, with parallel measuring loops and block/manifold connection. Nominal flow refers to approx. 10 m/s (33 ft/sec) velocity in measuring loops for best performance. Calibration to customer range, with increased accuracy, possible. M015 Page 2 of 7 / 18 November 2005 - v5

GENERAL OUTLINE DIMENSIONS RHM 015 Type I (w/ removable manifold block - serial [SM0] / parallel [PM0] / PTFE seals) Thread type: Flange type: Weight approx. 2.5 kg (5.5 lb) A1=130 mm (5.12") B1=25 mm (0.98") H1=172 mm (6.77") A2=145 mm (5.71") B2=40 mm (1.57") H2=188 mm (7.40") H2=196.5 mm (7.74") for brazed block version W=0 mm for NT and ET temperature models and W=100 mm for HT temperature models (*) (see pages 6 & 7). For ET1 and ET2 temperature models, terminal box will be replaced by 2 meters free teflon cable. Thread Standard Thread Optional Flange Standard Flange Optional Special Process Connection Face to face length (L) (**) Order Code G ¼" female 50 mm (1.97") G1 NPT ¼" female 50 mm (1.97") N1 Autoclave / Butech thread 70 mm (2.76") P1 M20 x 1.5 70 mm (2.76") XX ½" CL 150 acc. ANSI B16.5 220 mm (8.67") A1 ½" CL 300 acc. ANSI B16.5 220 mm (8.67") A2 ½" CL 600 acc. ANSI B16.5 220 mm (8.67") A3 DN15 / PN40 acc. DIN 2635 - C 220 mm (8.67") D1 DN15 / PN100 acc. DIN 2637 - E 220 mm (8.67") D2 ½" CL 900 / 1500 acc. ANSI B16.5 300 mm (11.82") A6 ½" / CL 2500 acc. ANSI B16.5 300 mm (11.82") A8 DN15 / PN160 acc. DIN 2638 - E 220 mm (8.67") D3 ½" JIS flanges standard - 220 mm (8.67") XX Swagelok standard - 190 mm (7.48") XX VCR standard - 190 mm (7.48") XX Novaswiss standard - 190 mm (7.48") XX (*) Type II or Type III preferred - see next pages. (**) Customization possible on request. Our standard seals are PTFE - Manifold block on request available without seals but with brazed connection block. The finish type of our ANSI flanges is RF/SF (AARH 125-250 (µinch) - Ra 3,2 up to 6,3 (µm)). Others available on request. Above table only shows our general process fittings. For further customization with regard to face to face length and special fittings please contact your local agent. M015 Page 3 of 7 / 18 November 2005 - v5

GENERAL OUTLINE DIMENSIONS RHM 015 Type II (sealless welded, parallel measuring loops w/o seals [PF0]) Flange type: Special fittings: A1=130 mm (5.12") B1=25 mm (0.98") H1=172 mm (6.77") A2=145 mm (5.71") B2=40 mm (1.57") H2=205 mm (8.07") W=0 mm for NT and ET temperature models and W=100 mm for HT temperature models (see pages 6 & 7). For ET1 and ET2 temperature models, terminal box will be replaced by 2 meters free teflon cable. Standard Optional Special Process Connection Face to face length (L) (*) Order Code ½" CL 150 acc. ANSI B16.5 220 mm (8.67") A1 ½" CL 300 acc. ANSI B16.5 220 mm (8.67") A2 ½" CL 600 acc. ANSI B16.5 220 mm (8.67") A3 DN15 / PN40 acc. DIN 2527 - C 220 mm (8.67") D1 DN15 / PN100 acc. DIN 2527 - E 220 mm (8.67") D2 ½" CL 900 / 1500 acc. ANSI B16.5 300 mm (11.82") A6 ½" / CL 2500 acc. ANSI B16.5 300 mm (11.82") A8 DN15 / PN160 acc. DIN 2527 - E 220 mm (8.67") D3 ½" JIS flanges standard - 220 mm (8.67") XX Free pipe ends 12.00 x 1.50 mm standard - 190 mm (7.48") XX Grayloc or equivalent hubb standard - 190 mm (7.48") XX Swagelok standard - 190 mm (7.48") XX (*) Customization possible on request. The finish type of our ANSI flanges is RF/SF (AARH 125-250 (µinch) - Ra 3,2 up to 6,3 (µm)). Others available on request. Above table only shows our general process fittings. For further customization with regard to special fittings and face to face length please contact your local agent. M015 Page 4 of 7 / 18 November 2005 - v5

GENERAL OUTLINE DIMENSIONS RHM 015 Type III (sealless welded, serial measuring loops - single path w/o seals [SF0]) Sanitary fittings: Flange / Other fittings: Weight approx. 3 kg (6.6 lb) A1=130 mm (5.12") B1=25 mm (0.98") H1=172 mm (6.77") A2=145 mm (5.71") B2=40 mm (1.57") H2=184 mm (7.25") for sanitary fittings H2=205 mm (8.07") for flange type W=0 mm for NT and ET temperature models and W=100 mm for HT temperature models (see pages 6 & 7). For ET1 and ET2 temperature models, terminal box will be replaced by 2 meters free teflon cable. Process Connection Face to face length (L) (*) Order Code Sanitary ½" Tri Clamp acc. DIN 32676 190 mm (7.48") S1 Fittings (**) DN10 / Sanitary acc. DIN 11851 190 mm (7.48") S2 Flange Other Fittings ½" CL 150 acc. ANSI B16.5 220 mm (8.67") A1 ½" CL 300 acc. ANSI B16.5 220 mm (8.67") A2 DN15 / PN40 acc. DIN 2527 - C 220 mm (8.67") D1 Swagelok standard - 190 mm (7.48") XX Free pipe ends 12.00 x 1.50 mm standard - 190 mm (7.48") XX (*) Customization possible on request. (**) Fitting material is 1.4435 / SS 316L. The finish type of our ANSI flanges is RF/SF (AARH 125-250 (µinch) - Ra 3,2 up to 6,3 (µm)). Others available on request. Above table only shows our general process fittings. For further customization with regard to special fittings and face to face length please contact your local agent. M015 Page 5 of 7 / 18 November 2005 - v5

GENERAL SPECIFICATIONS RHM 015 Approvals ATEX (CESI 02 ATEX 053 X) Ex II 1 G, EEx ia IIC T6-T1 CSA (220705) Class I, Div 1 and 2, Groups A, B, C and D; Type 3 Custody Transfer Approvals (PTB 1.32-97027224 and NMI TC 3382) PED according to directive 97/23/EC: available 3A Sanitary Approvals Electrical connection Junction box / aluminium coated (standard) IP 65 (Nema 4X) (Junction box in SS optional) Cable entry M25 x 1.5 (M20 x 1.5, ½" and ¾" NPT optional) Max cable length between RHM and RHE: 100 m (330 ft) 200 m (660 ft) only with factory approval Housing Stainless Steel: 1.4301 / SS 304 - others on request - Protection class: IP 65 (Nema 4X) - higher on request - Material of wetted parts 1.4539 / SS 904L (measuring loops) 1.4571 / SS 316Ti (process connection) Hastelloy C4 on request Tantalum on request Other material on request Pressure rating Pressured part of the meter consists of the measuring loops and the connection part. The weaker of both parts decides the maximum allowed operating pressure. Below is the max. operating pressure of the measuring loops (*). (*) These values are only valid for SS 316Ti & SS 904L materials. Statements for others materials on request. Standard version: 300 bar @ 120 C (4350 psi @ 248 F) 250 bar @ 210 C (3625 psi @ 410 F) 200 bar @ 350 C (2900 psi @ 662 F) wall thickness is generally 0.2 mm (0.008") Optional high pressure version: 400 bar @ 120 C (5800 psi @ 248 F) wall thickness is generally 0.25 mm (0.01") Extremely high pressure (up to 850 bar) - on request - Temperature rating NT Models from -20 to +120 C (-4 to +248 F) ET Models from -45 to +120 C (-49 to +248 F) ET1 Models from -200 to +50 C (-328 to +122 F) ET2 Models from -45 to +210 C (-49 to +410 F) HT Models from 0 to +350 C (+32 to +662 F) For further information please contact your local representative - to be continued with the order code on the next page - M015 Page 6 of 7 / 18 November 2005 - v5

ORDER CODE RHM 015 Order Code Structure The order code of the Rheonik Sensors consists of 6 sections (see previous pages / below). Restrictions of combinations may apply. For specials, please comment your needs in plain text / sketches. Temperature Rating T1 TA T2 T3 T4 NT Models (Normal Temperature Models) from -20 to +120 C (-4 to +248 F) ET Models (Extended Temperature Models) from -45 to +120 C (-49 to +248 F) ET2 Models (Extended Temperature Models) from -45 to +210 C (-49 to +410 F) ET1 Models (Extended Temperature Models) from -200 to +50 C (-328 to +122 F) HT Models (High Temperature Models) from 0 to +350 C (+32 to +662 F) Pressure Rating P1 Standard pressure version (300 bar @ 120 C / 4350 psi @ 248 F) - page 6 - P2 High pressure version (400 bar 120 C / 5800 psi @ 248 F) - page 6 - P3 Extremely high pressure version (on request) - page 6 - Construction Type PM0 Parallel Measuring Loops with removable Block/Manifold and PTFE Seals - page 3 - SM0 Serial Measuring Loops with removable Block/Manifold and PTFE Seals - page 3 - PF0 Parallel Measuring Loops Seal Less Welded Version - page 4 - SF0 Serial Measuring Loops Seal Less Welded Version / Single Path - page 5 - XXX Other construction type on request Material of Wetted Parts M0 M4 M5 MX 1.4539 / SS 904L (measuring loops) 1.4571 / SS 316Ti (connection part) Tantalum Hastelloy C4 (measuring loops) / Hastelloy C22 (connection part) Other material on request Process Connection XX Code available on pages 3, 4 and 5. Hazardous Area Approvals NN Without Ex Approvals AT ATEX Approvals (CESI 02 ATEX 053 X) - Ex II 1 G, EEx ia IIC T6-T1 CS CSA Approvals (220705) - Class 1, Div 1 / Group A, B, C, and D; Type 3 Order Code Example M##5 T1 P1 PM0 M0 G1 AT T1: NT (Normal Temperature Models) from -20 to +120 C (-49 to +248 F) P1: Standard pressure version (300 bar @ 120 C / 4350 psi @ 248 F) PM0: Parallel Measuring Loops with removable Block/Manifold and PTFE Seals M0: 1.4539 / SS 904L (measuring loops) 1.4571 / SS 316Ti (connection part) G1: Female Thread G ¼" AT: ATEX Approvals (CESI 02 ATEX 053 X) M##5 M015 Page 7 of 7 / 18 November 2005 - v5