DEVI EasyConnect Heating Cable Connection System

Similar documents
Terminator DP/FAK-4 and FAK-4L for In-Line Splice of Electrically Heated TubeTrace Bundles INSTALLATION PROCEDURES

SCTK INSTALLATION PROCEDURES. Splice Connection Termination Kit. SCTK-1 for BSX, RSX, VSX SCTK-2 for KSX, HTSX SCTK-3 for HPT, FP

Terminator DP/FAK-5 and FAK-5L

Terminator DL-S for use with BSX *, HTSX, KSX self-regulating, HPT power-limiting, and FP constant watt heating cables

Terminator DP/FAK-2 and FAK-2L. Elbow Splice Kit for Electrically Heated TubeTrace Bundles INSTALLATION PROCEDURES

In-Line / T-Splice Kit Installation Instructions. Terminator DS-L for use with RSX, TSX, VSX self-regulating heating cables

Terminator ZP/FAK-1 Kit Electrically Heated TubeTrace Bundles

PETK Power and End Termination Kit

PETK Power and End Termination Kit

Terminator ZP/FAK-5 and 5L

SCTK Splice Connection Termination Kit

Terminator ZP/FAK-4L Kit Electrically Heated TubeTrace Bundles

Terminator DP/FAK-4LHT Kit for In-Line Splice of Electrically Heated TubeTrace Bundles INSTALLATION PROCEDURES

C Power Connection Kit

C A HEATING CABLE GLAND KIT INSTALLATION INSTRUCTIONS

Terminator DP/FAK-5LHT Kit for Tee Splice of Electrically Heated TubeTrace Bundles INSTALLATION PROCEDURES

PETK Power and End Termination Kit

Power Connection Kit Installation Instructions. Terminator DP-M for use with TEK and HTEK series constant watt heating cables

UPC Power Connection Kit

ET-PWR-END-KIT Installation Instructions (part #JSR00)

C A Heating Cable Gland Kit Installation Instructions

Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 High voltage contacts Quick and easy assembling Protection class IP68 acc.

Terminator. DP Power Connection Kit INSTALLATION PROCEDURES

Power Connection Kit Installation Instructions. Terminator ZP-M for use with TEK and HTEK series constant watt heating cables

Terminator TM DL Lighted Power Connection/End Termination Kit INSTALLATION PROCEDURES. For Power Connection or End Termination Applications

Installation Instructions

Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 high voltage contacts Quick and easy assembling Protection class IP68 acc.

EPIC. Pin & Sleeve Connectors PIN & SLEEVE CONNECTORS

Assembly Instruction. EL OCHITO BLUE CONTACTS SuperSpeed USB TYPE I: PIN /SKT CABLE:

Assembly Instruction EL OCHITO WHITE CONTACTS 1000BASE-T/10GBASE-T TYPE I: PIN /SKT CABLE: S/FTP

General characteristics and technical data Series MCS

ZP-XP Power Connection Kit. Terminator. The Heat Tracing Specialists INSTALLATION PROCEDURES

FAK-7HTS High Temperature Tubing Bundle End Seal Kit INSTALLATION PROCEDURES

PRO-Tect Pipe Freeze Protection Self-Regulating Heating Cable Install Manual (PT-Series)

Han-Power Energy Bus Components

Installation Instructions (Translation) Marking. Description. Danger, warning and note symbols. Technical data. ANTARES ExtSet.

Installation Instructions

JBM-100-STB NEMA 4X-rated connection kit Installation Instructions

TracePlus. VIL-6 End of Circuit Light Kit INSTALLATION PROCEDURES. VIL-6-H for BSX, HTSX, KSX, HPT, FP VIL-6-V for RSX, TSX, VSX

MOTOR CONNECTIONS MOTOR-DECONTACTOR & INDUSTRIAL PLUGS & SOCKET-OUTLETS. hyconelec.co.za MARECHAL TECHNOLOGY

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

EPIC CIRCON M23 Series

Multipole Conductor Rail MultiLine Program 0831

HTSB system System overview

HEAVY-DUTY PLUGS & SOCKETS

HTP PTP/ PTJ Power Connection Kit for Pipes

Industrial, Heavy Insulated Mono-Tape. and Duo-Tape

Capacitors. Individual & fixed bank. Individual & fixed capacitor banks. Low Voltage Network Quality

FLX TM Self-Regulating Winterization/Freeze Protection INSTALLATION PROCEDURES

SERGE BARIL HA-S HAZARDOUS AREA SEAL KIT

TubeTrace Tubing Bundles

Segurança. Segurança. PSB Heating System Cold applied connection technology. Compulsório. Compulsório. Operation Manual and Installation Instructions

TSRT TSRT Tee Splice Kit Installation Instructions

SRK02 Hard Wire Power Connection Kit. Installation, Operation and Maintenance Instructions

Aqua-safe. Waterproof Plug & Socket Connectors Simply better designed

JBS-100-STB Single Entry Power Connection with Junction Box Installation Instructions

Electric Heat Tracing INSTALLATION PROCEDURES

Powerline QC. Single Power Connectors. Ten 47 Limited

Clearwater Tech - Phone: Fax: Web: -

Technical Data Sheet Shielded (CY) PVC Control Cable

3M Cold Shrink Silicone Rubber Outdoor Termination Kit QT-III 7600-S-3W Series

Data sheet chainflex CF210.UL

Installation & Operation Instructions. Type USL Signal Light Kit for Self-Regulating Constant Wattage Heating Cables. Constant Wattage Grommet

Benefits. Safety. Durability. Performance. Russellstoll. Heavy Industrial/ Marine

Application Specification Circular Plastic Connector (CPC) Series 45 System 05 AUG 14 Rev D

Power Connection Kit installation instructions

20 A / 32 A / 63 A DECONTACTOR MOUNTING: SWITCH SHOULD BE ON THE UPPER SIDE!

Data sheet chainflex CF8821

Tools, Equipment and Supplies Needed:

Nuheat WEATHER-READY HEAT TRACE PIPE FREEZE PROTECTION SYSTEM. Self-Regulating Heating Cable Installation Guide. UV Resistant Polyolefin Outer Jacket

Powerline. Single Power Connectors. Ten 47 Limited

Data sheet chainflex CF6

Individual & fixed bank capacitors

3M Cold Shrink Silicone Rubber Termination QT-III 7600-S-3G Series Three-Core Outdoor Termination

Electric Heat Tracing INSTALLATION PROCEDURES

3M Cold Shrink QT-III Silicone Rubber 3/C Cabinet Mount Termination Kit

AutoMatrix Power Connection Kit. (1) This type 4X enclosure is intended for indoor or outdoor use primarily to. (2) May be required (see step 1).

ABG Cable Glands Installation Procedure

Data sheet chainflex CF881

UES-LL End Termination Kit

Air Conditioner for M915 A0/A1 Truck

SWITCH SHOULD BE ON THE UPPER SIDE!

Holtumsweg 13, D Weeze, Tel /9134-0, Fax /1444

DEF-Trac. Design and Installation Guide. August 2015

Sconce INSTALLATION INSTRUCTIONS P C

14 HH EAC/CTP CE RoHS-II conform

Data sheet chainflex CF240

Data sheet chainflex CF886

SSX 19 PIN REVERSE SERIES

Pellet Furnace Last SN#

Segurança. Segurança. MSB/HSB Heating System. Compulsório. Compulsório. Operation Manual/Installation Instructions. Cold applied connection technology

Data sheet chainflex CF140.UL

Power-Limiting Cables

Data sheet chainflex CF10

Type LT Self-Regulating Heater Cable For use in Ordinary (Unclassified) and Hazardous (Classified) Locations

Datasheet. BL/SL 5.08 series BLF 5.08/02/180 SN OR BX

SC30 powered through NN3D (6 meter antenna cable)

Application Coding Cable diameter Color Part No. Std. Pack Part No. Std. Pack. Female connector. gray black gray black gray black green

PPT 802, Proximity Probe Transducer System

General Specifications for Lighthouse Power Pedestal

Transcription:

Installation Instructions DEVI EasyConnect Heating Cable Connection System IP 68 0 mm 10 20 30 40 50 60 70 80 90 100 110 120 Standards: DIN VDE 0606 T200, DIN EN 61984 (VDE 0627), VDE 0110 IEC 60999; CSA: C22.2 N. 182.2-M1987; LR Type Approval System DEVI EasyConnect enables you to modify your heat tracing circuit in 1 click. You can use the EasyConnect indoors as well as outdoors. The connectors are IP 68 rated by VDE and CE marked. This 3 pole Connector is rated for 240 Volt and 20 Amps and can be used within a temperature range of -40 to 100 C. These Installation Instructions will give you details about connecting the product to power and heat tracing cables as well as a few design tips. 130 140 150 160 WARNINGS To prevent electrical shock, short-circuit or sparks please read the installation manual of the connector and the heat tracing cable carefully before installation. Connect EasyConnect to the heat tracing cable and power cable only with the power switched off. Do not use this connector without using an earth leakage circuit breaker. Do not connect the two bus wires of the heat tracing cable together. This will cause a short circuit. Use for end termination the with end cap or an ETK, do not leave the end of the heat tracer unterminated. Avoid contact with water during the installation of the EasyConnect. Avoid contact with water during the installation of the heat tracing cable. Make sure that the connection is not immersed in water after installation. Use only 2,5 square non stranded power cable for the power connector.

The following installation procedures are suggested guidelines for the installation of DEVI EasyConnect Kits. Contents Overview: Item Description 1 Ground Sleeve 2 Large Crimp 3 Small Crimp 4 Compression Nut 5 Compression Nut 6 Cable Gland 7 Female Connector 8 Male Connector 9 ECEM 10 ET-6 End Cap 11 ET-60 Over End Cap 12 RTV Sealant 13 14 15 16 EC-JB4 1 2 3 4 5 6 7 8 10 11 12 13 14 15 16 NOTE: Items shown above are a comprehensive overview of DEVI EasyConnect fi ttings. Refer to individual kits below for items included. 9 EC-1 Kit Contents EC-2 Kit Contents EC-3 Kit Contents EC-1 + ETK Kit Contents EC-T1 Kit Contents EC-T2 Kit Contents Tools Required... EC-ETK Kit Contents EC-JB 4 Kit Contents 2

Heating Cable Fabrication... Heating Cable Cable Gland Remove Grommet 30 mm Ground Braid Compression Nut 1. Slide the compression nut over the cable. Slide the cable gland over the cable with the small opening facing the compression nut. Remove the black grommet and discard. Slide on to the cable. 2. Remove 30mm of the outer jacket. Do not cut the ground braid under the outer insulation jacket. Do not cut or damage the ground braid. 3. Pull back the ground braid to allow for further fabrication. Conductive Matrix 10 mm 15 mm 12 mm 4. Remove 10mm of the exposed cable. 5. Remove 15mm of the primary insulation jacket to expose the conductive matrix. 6. Remove 12mm of the conductive matrix. Start by skiving the sides of the matrix to expose the bus wires. Pull bus wires from matrix. Remove matrix carefully. Do not cut bus wire strands. Do not cut or damage the bus wire strands. Male Connector Ground Braid Crimps 7. Slide a small crimp over the exposed bus wires. Crimp towards the inner edge to hold in place. Use caution to not deform the outer end of the bus wire crimps as they will need to fi t into the electrical terminals. 8. Insert the crimped bus wires into the designated male connector terminals (L and N) and fasten tightly. Make sure the connector is aligned properly with the latch holes. Rotate the connector if alignment is needed. The crimp will fl atten as the terminal screw is tightened. To prevent arcing, make sure all wire strands are securely fastened. 3 9. Twist the ground braid to form a single strand. Make sure the strand is located on the same side of the ground terminal to allow for sufficient length to be inserted into the terminal.

Heating Cable Fabrication Continued... Large Crimp Ground Sleeve 10. Slide a large crimp over the twisted ground braid. Crimp towards the inner edge to hold in place. Slide the ground sleeve over the crimped ground strand. 11. Insert the crimped and sleeved ground braid into the designated terminal. Tighten until the terminal screw bottoms out. The crimp will fl atten as the terminal screw is tightened. To prevent arcing, make sure all wire strands are securely fastened. 12. Slide the toward the connector and connect making sure the latches click into position. Slide the compression nut forward and engage the threads. Tighten securely. End Termination Fabrication... Heating Cable 1. Apply a liberal amount of RTV Sealant to the end of the heating cable. 2. Apply a liberal amount of RTV Sealant to the inside of the ET-6 end cap. ET-6 End Cap 3. Slide the ET-6 end cap over the end of the heating cable. ET-6 End Cap ET-60 Over End Cap 4. Apply a liberal amount of RTV Sealant to the outside of the ET-6 end cap. Slide the ET-60 end cap over the end of the ET-6 end cap. 4

Fabrication... Power Wires 15 mm 9 mm Compression Nut 1. Slide the compression nut and onto the power cable. Proper orientation is required to allow for assembly after electrical connections are made. 2. Remove 15mm of the outer jacket. Do not cut the power wires under the outer insulation jacket. 3. Remove 9mm of the power wire insulation. Do not cut or damage the power wires. Do not cut or damage the wire strands. Large Crimp Female Connector Ground Sleeve Crimps 4. Slide small crimps over the exposed black and white wires and a large crimp over the green ground wire. Crimp towards the inner edge to hold in place. Use caution to not deform the outer end of the wire crimps as they will need to fi t into the electrical terminals. 5. Insert the crimped power wires into the designated female connector terminals (L and N) and fasten tightly. Make sure the connector is aligned properly with the latch holes. Rotate the connector if alignment is needed. The crimp will fl atten as the terminal screw is tightened. To prevent arcing, make sure all wire strands are securely fastened. 6. Slide the toward the connector and connect making sure the latches click into position. Slide the compression nut forward and engage the threads. Tighten securely. Connect the to the. Make sure the latches click into position. Do not separate when energized. 5

Kit Configurations: Model: EC-1 Model: EC-2 Power To Connection Kit (ART. NO. 98300870) ECEM Power To (2) s Connection Kit (ART. NO. 98300875) Model: EC-3 Model: EC-1 + ETK ET-60 Over End Cap Power To (3) s Connection Kit (ART. NO. 98300876) Model: EC-T1 Power To With End Termination Kit (ART. NO. 98300873) Model: EC-T2 ECEM To Connection Kit (ART. NO. 98300871) ECEM To (2) s Connection Kit (ART. NO. 98300874) Model: EC-ETK ET-60 Over End Cap Model: EC-JB4 End Termination Kit (ART. NO. 98300872) Junction Box Power to (4) s Kit (ART. NO. 98300877) Specifi cations and information are subject to change without notice. Form: CPD1075-1211