WILDLIFE PROTECTION

Similar documents
Guying - Insulator Dimensional Requirements ** Lightning Protection & Grounding - Grounds

Poles - General Unguyed Single Phase Composite Poles Poles - General Unguyed Three Phase Composite Poles

CABLE TERMINALS

LABOR OPERATIONS

Wildlife Protection Products

Wildlife Protection Products. Jerry Liguori

SECTION 8 - SWITCHES AND PROTECTIVE DEVICES TABLE OF CONTENTS

Wildlife Protection Products

Molded Product Catalog. A Marmon Wire & Cable / Berkshire Hathaway Company

Technical Specification for Pole Mounted Capacitor Rack

METER INSTALLATIONS

SECTION 3 - PRIMARY CONSTRUCTION OVERHEAD TABLE OF CONTENTS

Honeywell Salisbury Outage Protection. Bushing Covers, Conductor Covers, Instant Insulation

When power interruptions happen.

Pentahead bolts See note 2. Conduit run as specified. Company facility. Refer to drawing SS8.6-2 or SS8.6-3 STANDARD SERVICE INSTALLATION

Outdoor Distribution (15 kv through 25 kv) S&C Fault Tamer Fuse Limiter

D9-3. No. WIRING DIAGRAM CONNECTIONS FOR UNDERGROUND SELF CONTAINED METERS JRH JED krich95 LINE LINE ABCN SOURCE SOURCE GROUND GROUND STUD STUD SOURCE

S&C Fault Tamer Fuse Limiter. Outdoor Distribution (15 kv through 25 kv)

34.00 METERING GENERAL LABELING MULTIPLE METER ENCLOSURES ON A SINGLE PREMISE

Wildlife Power Outage Protection Products

SYSTEM PROTECTION - PLATING

outage protection Q: Why should I use outage protection?

RISER POLES RISER POLES. Overhead Electric Distribution Standards INTRODUCTION

Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary

Polymer Insulators A Better Solution

UG FEEDING OH UG FEEDING OH. Electric Distribution Standards I. INTRODUCTION

CONSTRUCTION STANDARD ELECTRIC OPERATIONS ORGANIZATION

3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits

CONFIGURATIONS TABLE OF CONTENTS PHASE LOCATIONS (PREFERRED LOCATIONS) STRUCTURAL ELEMENTS DESIGN LIMITS

BRACKETS, MOUNTS & HARDWARE

DISTRIBUTION PRODUCTS

COOPER POWER SERIES. S.T.A.R. type LVR faulted circuit indicator installation instructions. Fault Indicators MN320005EN

M-Force three-phase switch

Convertible - Rated 3 4-Ton /2-Ton Nylon Strap Hoists Refer to any questions about the use, application, repair or testing of this hoist to:

3M Cold Shrink Silicone Rubber Termination QT-III 7600-S-3G Series Three-Core Outdoor Termination

Customer Requirements Clearance Requirements for Overhead Joint Utility Construction

BREAK-SAFE Load Break & Pick-up Tool

Single phase pole mounted. 11kV. Electrical Engineer KEU ID#:

Pretest Module 29 High Voltage Unit 1

Disconnect & ByPass Switches

MINIMUM DISTRIBUTION SYSTEM CONCEPTS AND APPLICATIONS. Larry Vogt. Manager, Rates

BREAK-SAFE Load Break & Pick-up Tool

Instructions for Field Retrofit of a Model 98 Temperature Controller in place of a Model 85 Temperature Controller

OVERHEAD SERVICE. Items to consider

Installation Instructions LINK---C

Surge Arresters. UltraSIL Polymer-Housed VariSTAR Surge Arresters: Normal-Duty (5 ka), Heavy-Duty (10 ka), and Heavy-Duty Riser Pole (10 ka)

TABLE OF CONTENTS GUY PLACEMENT PERPENDICULAR TO LINE PARALLEL TO LINE GUYING INSULATOR DIMENSIONAL REQUIREMENTS MINIMUM CLEARANCES GUY TO CONDUCTOR

TRELLEBORG ENGINEERED PRODUCTS. Electrical Safety Products

Engineering Service Specifications. Commercial Single-Phase Current Transformer Metering Schemes

COOPER POWER SERIES. UltraSIL polymer-insulated D-73P disconnect switches installation instructions. Switches MN008004EN

JUMPERS & SWITCHING TOOLS

COOPER POWER SERIES. K-Limiter back-up current-limiting fuse installation instructions. Fusing Equipment MN132010EN

Installation Instructions Table of Contents

D-73P disconnect and bypass switches

WARNING NOTICE CAUTION ASSEMBLY INSTRUCTIONS

Solid Dielectric, Single Phase Recloser

OUTDOOR LIGHTING

Cobra-S. Catalog Cobra-S

Catalog 14A January 2013

M-Force three-phase switch

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES

AGRICULTURAL UNDERGROUND SERVICE 500 HP OR LESS

Wisconsin Public Utility Institute. June 28, Minimum Distribution Charges. Larry Vogt. Director, Rates Mississippi Power

(12) United States Patent (10) Patent No.: US 7,009,102 B2

CAT-1 Series 3. Installation Guide. The Valley Group, Inc. 871 Ethan Allen Hwy. Suite 104 Ridgefield, CT 06877

9. Non-Residential Services (Commercial, Industrial, and Agricultural)

35-kV Thru-Bushings F Series (bolt-in) for Air-Insulated to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

STRAIN LINK STICK ROLLER LINK STICK ADJUSTABLE STRAIN POLES SPIRAL LINK STICK TRANSMISSION TOOLS

K Autoslide. HJ26141, Rev 13 12/18

Surge Arresters. UltraSIL Polymer-Housed Evolution (10 ka) Surge Arresters. General. Construction. features

Shakespeare s ruggedly engineered FRP poles are essential electric utility assets for today s modern, resilient grid.

UNDERGROUND SERVICE ENTRANCE LOCATION. No meter base or entrance should be installed before an KREMC engineer has checked the proposed location.

Jumpers & Load Pickup Tools

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8(S)-JCN

Cold Shrink Silicone Rubber Termination QT-III 7672-S-8-JCN

CPCS the U.S.A.

16kA Solid Dielectric, Triple Option Reclosers Catalog VLT12

INSTALL SERVICE- ENTRANCE SYSTEMS

SYSTEM PROTECTION SYSTEM PROTECTION. Underground Electric Distribution Standards I. FUSE COORDINATION

HUBBELL Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary

PROTECTION ARRESTERS FUSES WILDLIFE

UPPCO SERVICE MANUAL

Distribution Arresters

PROJECTS $500K AND OVER FOR 2014

15 kv and 25 kv Thru-Bushings

COMMERCIAL QUICK REFERENCE

Electrical Awareness for Construction Activities. Overhead Power Lines & Underground Cables

Rigid Entry Boots REB & RDEB. Installation Instructions

PAGE 1. 7/18 HJ26141 Rev 12

Three-Phase Pole Mounted Recloser

T & D Inventory Items Bidder Price List Group 1: 120V/240V Pole Mounted Transformers ASPA ITEM NO.

Surface Regulations and Policies

OFFICE PARTITIONS. Data Port Openings. Use cable tie bracket to dress data cables under panels. STEP 1

K Autoslide & K Autoslide

OVERHEAD DESIGN MANUAL

REVISION DESCRIPTION:

BWS/MSY-40 Cable stripping machine Operational Manual Bluedog Cable Strippers

DC Series Installation Manual (# )

GPS AutoSteer System Installation Manual

COOPER POWER SERIES. Screened Separable Connectors MN650023EN. Effective October 2016 Supersedes March 2012 (IS )

Transcription:

05 00 00 01 TABLE OF CONTENTS GENERAL INFORMATION INSTALLATION OF CRITTER LINE GUARDS INSTALLATION OF TANK MOUNTED LIGHTNING ARRESTER BRACKET GUARDS 25KV & BELOW EXISTING STRUCTURE MODIFICATION 05 00 00 02 05 00 00 04 05 00 00 05 05 11 10 ** 25 KV & BELOW NEW STRUCTURE CONSTRUCTION 05 11 20 01 25 KV & BELOW TRANSFORMER COVER 05 12 10 01 25 KV & BELOW RECLOSER AND SECTIONALIZER RETROFIT 05 14 10 ** 25 KV & BELOW CUTOUT COVER 05 15 10 01 25 KV & BELOW CONDUCTOR COVER SINGLE PIN 05 16 10 ** 25 KV & BELOW CONDUCTOR COVER DOUBLE PIN 05 16 11 ** 25 KV & BELOW CONDUCTOR COVER DEADEND 05 16 12 ** REV. DATE: 10/21/15

GENERAL INFORAMTION 05 00 00 02 Purpose and Scope This section covers the current products and construction practices for the protection of avian species common to Ameren s service areas in Illinois and Missouri. In addition, the wildlife guards for prevention of animal caused outages are included to improve reliability of distribution facilities. Ameren s first approach is to maintain minimum horizontal and vertical conductor separation unless economics or existing conditions force the use of other methods. The areas intended for new overhead lines shall be evaluated for risk to the protected birds (resident or migratory). Lines scheduled for repair or replacement shall also be evaluated for this same risk. Practices and Products All Divisions must follow Ameren standards for new construction and existing retrofit to provide avian friendly facilities. Other suggested practices or products are not acceptable unless evaluated and approved by Standards. Wood or composite poles are preferred because the insulating nature of these materials reduces the clearances required for avian protection to less than those required for metal structures. After completion of construction all leftover scrap or reusable material shall be removed and disposed of in an appropriate manner. Regulations and Compliance All legal procedures must be followed by the Ameren Division when there is evidence of an avian injury or fatality in the vicinity of an Ameren overhead line (69 kv and below). In addition, the Division shall be proactive in correcting or modifying existing structures to eliminate the possibility of further injury or fatalities to avian species. This commitment is to meet the regulatory requirements for protecting avian species on new and existing circuits. The laws that are applicable are: 1. The Migratory Bird Treaty Act (MBTA; 16 U.S.C. 703 712). 2. The Endangered Species Act (ESA; 1531 1544). 3. The Bald and Golden Eagle Protection Act (BGEPA; 16 U.S.C. 668 668d) 4. Ameren Avian Protection Plan REV. NO: NEW REV. DATE: 04/29/10

Installation of Critter Line Guards 05 00 00 04 Sheet 1 of 2 1. General The stock number for the critter line guard is 71 25 216. The line guard is used to prevent animals from crossing a section of overhead conductor leading to a substation or other distribution equipment. If the line guard is installed on an energized conductor, proper protective clothing, equipment and procedures must be followed. 2. Principle of Operation The line guard includes five (5) rollers, two (2) wheels, two (2) L brackets, and six (6) cable ties. When properly installed the five rollers are placed between the two wheels and secured in place with the L brackets. When an animal (squirrel) tries to cross over the installed line guard, the rollers will rotate and the animal will be rolled off of the conductor. Line guard can be applied to lines with a voltage level of 69kV or less. 3. Line Guard Placement and Installation A. For substation applications, place the line guard at least 5 outside the substation fence. B. For other applications, place the line guard at least 2 from the pole or standing structure. C. Verify the size (OD) of the conductor that the line guard will be installed on. The line guard rollers are fabricated with a 1 OD hole and two cutouts, one for 2 OD and another for 3 OD. The first groove on each roller represents 2, and the second groove represents 3. The cutouts can be easily removed with a knife. Position one of the L brackets closest to the point the line guard will be protecting. If this work is being done with the conductor energized the L bracket can be replaced with a hot line clamp from the table on Sheet 2 of this standard. The hot line clamp can be installed with a shotgun hot stick. If the L bracket is used place it on the conductor and secure it into place with two cable ties. The cable ties must be placed through the holes provided and around the conductor. Pull the ties tight to hold the L bracket in place. NOTE: The stainless steel cable ties will have sharp edges if the ties are cut off. Therefore, the ends of the ties should be bent over to remove any sharp edges. D. Position the halves of the rollers around the conductor and snap them together. Each roller will have a series of four snaps. All of the snaps must be fastened. NOTE: On conductors larger than 2 OD, the rollers will have only two snaps. If the cutout for a 3 hole is removed, the end snaps will also be removed. This will not affect the integrity or operation of the product. E. While assembling the first and last rollers the wheels must be installed. Spread apart a wheel and place it on the end of the roller that faces the L bracket. Tightly fasten one cable tie at the base of the wheel (See Figure 1) to secure it to the roller. FIGURE 1 F. After all of the rollers have been snapped around the conductor, push the line guard assembly along the conductor until it is snug against the installed L bracket. REV. NO: 2 REV. DATE: 09/23/15

Installation of Critter Line Guards 05 00 00 04 Sheet 2 of 2 G. Position the remaining L bracket (or hot line clamp) at the opposite end of the line guard assembly and secure it in place with two cable ties as described in Step #3.C. Remember to bend the ends of the stainless steel ties to eliminate any sharp edges. 4. When the line guard installation is complete, it should appear as shown in Figure 2. Available Hot Line Clamps: FIGURE 2 Stock Number Material Conductor Range (Inches) DOJM Code 23 78 394 Copper 0.128 0.414 HLC10C 23 78 183 Copper 0.162 0.745 HLC350C 17 62 088 Aluminum 0.157 0.905 HLC336A 17 62 112 Aluminum 0.502 1.031 HLC556A 17 62 143 Aluminum 0.939 1.490 HLC954A REV. NO: 2 REV. DATE: 09/23/15

Tank Mounted Lightning Arrester Bracket Guard 05 00 00 05 1. GENERAL The lightning arrester mounting bracket guard is used to prevent bird caused outages associated with birds perched on the grounded LA bracket making contact with an energized line lead. 2. PRINCIPLE OF OPERATION The LA bracket guard covers the grounded metal mounting bracket and arrester mounting bolt on tank mounted arresters. The guards have flexible fingers that securely hold the guards in place. The guard is designed to fit brackets from all common polymer arrester suppliers. The guard has been tested to withstand 21kV to ground without a flashover. The smooth, rounded profile of the guard acts as a perch deterent. The UV stabilized polypropylene material exhibits excellent durability in all environments. See Figure 1. Figure 1 3. INSTALLATION A. Make sure that the arrester is positioned properly and securely attached to the tank mounting bracket. B. Place the wildlife guard over the last insulating rib on the polymer arrester mounting bracket and over the tank mounting bracket and bolt. C. Push down on the wildlife guard until the flexible fingers, at the base of the guard, snap into place and securely hold the guard. No external ties or tape are required to hold the wildlife guard in place. See Figure 2 for an example of an installed cover. Figure 2 Stnd. / Stk. No. Description 05 00 00 05 QTY A 69 56 037 Guard, Wildlife, for Covering LA Tank Bracket 1 B Wildlife Guards Installation OP Code 111 1 ENG: HLH REV. NO: NEW REV. DATE: 02/18/14

25 kv & Below Existing Structure Modification 05 11 10 ** This standard provides for modification of existing structures to increase spacing between conductors to reduce the likelihood of injury to or death of protected avian species. The 3 wire and 4 wire modification achieves mandated conductor spacing while retaining the eight foot crossarm used in the standard configuration. 6 A,B,F 6 A,B,F G,J G,J 2 6 D 2 6 D I I 8 8 2 6 3 8 2 6 3 8 6 2 36 6 6 C,F,H I,J 2 3 Wire Modification 05 11 10 01 4 Wire Modification 05 11 10 02 4. See Dist. Std. 06 12 01 for insulator detail and 06 01 01 for secondary clevis detail. 5. See Dist. Std. 29 00 17 02 for neutral ground clearance. Stnd. / Stk. No. Description 05 11 10 ** 01 02 A 25 05 069 Insulator, Pin type 1 1 B 23 62 156 Pin, Pole Top, 24 1 1 C 23 06 040 Clevis, Sec., Insulator 1 D 41 01 006 Crossarm, Wood Bayonet, 3 1/2 x 4 1/2 x 6 1 1 @ F TT*W Top Tie, See Dist. Std. 07 00 41 00 1 1 ST*W Side Tie, See Dist. Std. 07 00 41 00 1 G 23 52 058 Bolt, Mach., 5/8 x 5 2 2 H 25 59 044 Insulator, Spool 1 I 23 52 063 Bolt, Mach., 5/8 x 10 2 2 23 52 065 Bolt, Mach., 5/8 x 12 1 J 23 66 027 Washer, Square, 2 1/4 4 5 REV. NO: NEW REV. DATE: 04/29/10

25 kv & Below New Structure Construction 05 11 20 01 Ameren has several overhead flat configurations for use at 25 kv & below. The existing configuration may be on wood, steel or composite poles. Wood and composite poles are considered standard construction in areas with migratory bird population. New construction with crossarm configurations shall provide five feet conductor separation to reduce avian electrocution risk. 4 A,B,F H,J 2 2 E A,C,F 1 0 4 8 5 0 1. See Dist. Std. 06 12 01 for insulator detail. Stnd. / Stk. No. Description 05 11 20 01 A 25 05 069 Insulator, Pin type 3 B 23 62 156 Pin, Pole Top, 24 1 C 23 62 028 Pin, Crossarm 2 E 41 01 285 Crossarm, Fiberglass, 3 5/8 x 4 5/8 x 10 1 @ F TT*W Top Tie, See Dist. Std. 07 00 41 00 3 H 23 52 063 Bolt, Mach., 5/8 x 10 2 I 23 52 097 Bolt, Mach., 3/4 x 12 2 J 23 66 027 Washer, Square, 2 1/4 4 REV. NO: 1 REV. DATE: 03/29/11

25 kv & Below Transformer Cover 05 12 10 01 The transformer live parts should be covered to prevent circuit outage from wildlife contact. On Delta Primary Systems, wildlife guards must be installed on both HV bushings. When transformers are banked and the clam shell wildlife guard is used, install the arrester lead in the side of the guard so that the primary leads can be installed in the top holes. D B C 1 2 A 3 1. Bolt lead to arrester away from the transformer to keep the lead opening in the arrester guard away from animals. 2. Be sure the bushing guard completely covers the terminal and only the top bushing skirt. 3. Refer to DCS Section13 for transformer installation. Stnd. / Stk. No. Description 05 12 10 ** 01 A 69 56 037 Guard, Wildlife, Arrester Bracket 1 B 69 58 178 Wire, Lead, Arrester w/terms 1 C 69 58 296 Guard, Clam Shell, Wildlife 1 D 18 51 025 Wire, Transformer Riser (ft.) 6 F 111 Wildlife Guard Installation 1 REV.1 REV. DATE: 10/15/15

25 kv & Below Recloser & Sectionalizer Retrofit 05 14 10 ** The recloser live parts should be covered to prevent circuit outage from wildlife contact. 3 1. Bolt lead to arrester away from the tank to keep the lead opening in the arrester guard away from animals. 2. Be sure the bushing guard completely covers the terminal and only the top bushing skirt. 3. Refer to Dist. Section 10 for recloser and sectionalizer installation. 4. An arrester should be installed if one is not present. Stnd. / Stk. No. Description 05 14 10 ** 01 02 03 A 10 01 145 Arrester 10kV w/o Bracket 1 1 1 B 69 58 178 Wire Lead, Arrester w/terms 1 1 1 C 69 58 296 Guard, Clam Shell, Wildlife 2 2 2 D 18 51 025 Wire, SD., #4 Cu., Poly (ft.) 12 18 51 042 Wire, SD., #1/0 Cu., Poly (ft.) 12 18 51 023 Wire, SD., #4/0 Cu., Poly (ft.) 12 E 111 Wildlife Guard Installation 1 1 1 REV. NO: 1 REV. DATE: 09/28/15

25kV & Below Cutout Cover 05 15 10 01 The cutout live parts cover shown in this standard shall be used on the Ameren Distribution System to prevent circuit outage from wildlife contact. The cover is not intended for personal protection. CAUTION: AT TEMPERTURES BELOW 0 O F THE CUTOUT COVERS BECOME RIGID AND LOSE THEIR FLEXIB- ILITY. INSTALLING THE COVERS WITH A HOTSTICK MAY CAUSE THE COVERS TO BREAK. 1. Can be installed with live line tools. 2. Refer to Dist. Std. 10 12 01 ** for cutout installation. 3. The cover is intended for wildlife outage only. 4. Install the cutout cover from the front side. Push the cutout cover around the conductors. Pull the cover down until the interior fingers fully engage the sleet hood. Stnd. / Stk. No. Description 05 15 10 ** 01 A 23 17 411 Cover, Cutout 1 B 111 Cutout cover Installation 1 ENG:JWC REV. NO: 1 REV. DATE: 10/21/15

25kV & Below Conductor Cover Single Pin 05 16 10 ** The conductor and insulator cover shown in this standard shall be used on Ameren Distribution System to prevent avian outage from distribution facilities where horizontal conductor spacing is less than five feet. The cover is not intended for personal protection. B A 01 1. The cover is intended for wildlife outage only. 2. The cover can be installed with live line tools. 3. Cover fits #6 to 556 conductor on 55 5 pin, and 56 1 pin. 4. Install two covers on two interior positions when existing arm has four conductor configuration. 4 Stnd. / Stk. No. Description 05 16 10 ** 01 02 A 23 17 406 Cover, Single Pin Configuration 1 2 B 23 17 416 Cover, Extension Arm 2 4 C 111 Wildlife cover Installation 1 2 REV. NO: 1 REV. DATE: 09/29/11

25kV & Below Conductor Cover Double Pin 05 16 11 ** The wire and insulator cover shown in this standard shall be used on Ameren Distribution System to prevent avian outage from distribution facilities where horizontal conductor spacing is less than five feet. The cover is not intended for personal protection. B A 01 1. The cover is intended for wildlife outage only. 2. The cover can be installed with live line tools. 3. Install two covers on two interior position when existing arm has four conductor configuration. 3 Stnd. / Stk. No. Description 05 16 11 ** 01 02 A 23 17 408 Cover, Double pin configuration 1 2 B 23 17 416 Cover, Extension arm 1 4 C 111 Wildlife Cover Installation 1 2 REV. NO: 1 REV. DATE: 09/29/11

25kV & Below Conductor Cover Deadend 05 16 12 ** The conductor and insulator cover shown in this standard shall be used on Ameren Distribution System to prevent avian outage from distribution facilities where horizontal conductor spacing is less than five feet. The cover is not intended for personal protection. C B A 01 1. The cover is intended for wildlife outage only. 2. Can be installed with live line tools. 3. Install two covers on two interior positions when existing arm has four conductor configuration. 3 Stnd. / Stk. No. Description 05 16 12 ** 01 02 A 23 17 409 Cover, DE 2 4 B 23 17 413 Cover, Loopover, up to 0.5 Cond. Diameter 10 20 23 17 414 Cover, Loopover, 0.5 to 0.856 Cond. Diameter 10 20 C 23 17 415 Tape, Insulating 1 1 D 111 Wildlife cover Installation 1 2 REV. NO: 1 REV. DATE: 09/29/11