SLIDING GLASS DOOR - NON-IMPACT

Similar documents
PREMIUM VINYL VINYL SLIDING PATIO DOOR MULTI-SLIDE PATIO DOOR TABLE OF CONTENTS

(65=2=.kIB D /-Et I'F A " 1-» SINGLE HUNG - LARGE MISSILE IMPACT. 0 ANORL VY 7-4, 0-4 t<f] 50 E N ,Ez'$ No P % I -.

Architect Series Traditional. Min. Frame Width

Architect Series Traditional. Min. Frame Width. Five Panel 4XO O3X O7X O3X-3XO

cero by NanaWall The Minimal Framed Large Panel Sliding Glass Wall

CASEMENT - LARGE MISSILE IMPACT

CONSTRUCTION CONSULTING LABORATORY, INTERNATIONAL

Architect Series Traditional

Aluminum Wood Double-Hung Windows

ALUMINUM HORIZONTAL ROLLER WINDOW

U.S. ALUMINUM 3025 SERIES SLIDING DOORS

Ariel Sliding Patio Doors

Aluminum Sliding Glass Corner Meet Door Series SGD680 Product Specifications

400 Series Gliding Windows (1991 to Present)

SINGLE SLIDING WINDOW 1000 SERIES 4-1/2" FRAME SINGLE SLIDER LIFT OUT

AlumaView AV200. A. Section Metal Fabrications: Miscellaneous for steel supports.

400 Series Gliding Windows (1991 to Present)

400 Series Gliding Windows (1991 to Present)

1010C Sliding Mall Front

Sliding Patio Doors Builders Vinyl

Visions 2000 Double Hung Tilt Window Parts Reference Catalog

100 Series Gliding Windows (2008 to Present)

CHAPTER 3 INTEGRITY WOOD ULTREX DOUBLE HUNG

Reliance BlastMax Blast Resistant Curtain Wall Wet Glazed

Strength, Style and Security for your home and family

Strength, Style and Security for your home and family

Sentinel Single Hung Window 110

AAMA/WDMA/CSA 101/I.S.2/A440-08

100 Series Gliding Windows (2008 to Present)

Series 6000 XT - Thermal Storefront 2 x 6-1 Glass

Lift Slide Tracks, Thresholds, Gaskets and Interlocks.

DESIGN DATA Two-Panel Vent-Fixed (XO) or OX Equal Sash Units

Durulite Door Hardware Manual

Sliding Windows Brickmould Vinyl

100 Series Gliding Windows (2008 to Present)

/TRA BuyLine 1561

100 Series Gliding Doors (2009 to Present)

400 Series Flexiframe Windows (1985 to Present)

SECTION METAL LOCKERS. A. ADAAG - Americans with Disabilities Act, Accessibility Guidelines.

LIGHT DUTY ROLL UP DOOR

AAMA/WDMA/CSA 101/I.S.2/A TEST REPORT. Rendered to: MASTER WINDOW SYSTEMS, INC.

EURO VISTA FOLD. Approved for use in Miami-Dade HVHZ Zones Florida Building Code Approved Product Approval FL FOLDING SLIDING STACKING PIVOT

Springline Windows (1994 to Present)

HORIZONTAL SLIDER - NON-IMPACT

TS19 AA OVERVIEW. Glazing: Weight: Each panel weighs approximately 7to 8 lbs per sq ft depending on overall panel size.

National Guard Products, Inc. The products you count on. The people you trust.

SECTION METAL LOCKERS. A. ADAAG Americans with Disabilities Act, Accessibility Guidelines.

AAMA/WDMA/CSA 101/I.S.2/A440-08

Pella Impervia 350 Series Vinyl Awning Windows and Sliding Patio Doors

StyleGuard. Impact-Resistant Windows and Doors Edition

400 Series Springline Windows (1994 to Present)

SECTION [ ] SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

TM MANUFACTURERS

100 Series Single-Hung Windows (2008 to Present)

INTERIOR INSTALLATION

400 Series Flexiframe Windows (1985 to Present)

EPICVUE CLAD-WOOD PATIO DOOR SLIDING PATIO DOOR TABLE OF CONTENTS

HURRICANESHIELD IMPACT-RESISTANT GLASS SECTION DIRECTORY. Size and performance summary. Glazing performance. Grille profiles and patterns.

SECTION SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

889 High Performance Sliding Door

LUXURY SLIDING PATIO & SWINGING FRENCH DOORS

350/500 Tuffline TM Entrances 1

The Falcon Series... Setting The Standard

Visions 3000 Series 924 Parts Catalog

Thresholds & Weatherstripping

Guide Specification SECTION VINYL WINDOWS

Flexiframe Windows (1985 to Present)

Size and performance summary. Glazing performance. Grille profiles and patterns. Size tables. Design Data. Detailed Product Description

ENTRANCEWAYS. CUSTOM SIZING in 1 8" (3) increments SECTION REFERENCE ENTRANCEWAYS. Residential Springline Entry Doors

THERMOTITE 800C 800C SERIES ROLLING SERVICE DOORS WAYNE DALTON COMMERCIAL DOOR SYSTEMS INSULATED ROLLING STEEL DOORS CUT YOUR TOTAL ENERGY COST

400 Series Springline Windows (1994 to Present)

500 SERIES REINFORCED WOOD FRAME FOR EASY INSTALLATION

DIVISION: METALS SECTION: COLD-FORMED METAL FRAMING REPORT HOLDER: WARE INDUSTRIES D/B/A MARINO\WARE

Eclipse C3 Aluminum Folding Door System. Dealer Brochure Exterior folding door systems

Moisture prevention. Eco friendly. Will not mould. Heat/cold resistance. Buckingham. Eco-Series Patio Door

Sliding Patio Doors Flat Casing Vinyl

FG-2000 Storefront - Center Set 1-3/4 x 4 1/2

Sliding Windows Builders Vinyl

Single-Hung Windows Builders Aluminum

Perma-Shield Gliding Patio Doors

24" DLO 24" DLO 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" " FRAME DIMENSION 34" DAYLITE OPENING 1/8" 85 1/2" FRAME DIMENSION 3 OPP 3.

Construct Compressed Air Building Near Bldg SECTION OVERHEAD COILING DOORS 07/07

81870 Alside_24667 Alside 11/3/16 5:01 PM Page 2 80 Series

Moisture prevention. Eco friendly. Will not mould. Heat/cold resistance. Buckingham. Eco-Series Patio Door

NOTE: Refer to hardware list provided to identify fasteners supplied. Figure 2-1

V3 Series Awning Windows (2011 to Present)

Product Guide Specification

VINYL WINDOWS & DOORS

Size and performance summary. Glazing performance. Grille profiles and patterns. Size tables. Design Data. Detailed Product Description

5820 / 5920 SERIES DOOR

Section Traffic Doors

SECTION METAL LOCKERS

100 Series Awning Windows (2008 to Present)

100 Series Awning Windows (2008 to Present)

Size and performance summary. Glazing performance. Grille profiles and patterns. Size tables. Design Data. Detailed Product Description

SteelForm S-24C SECTIONAL OVERHEAD DOORS

260/360/560 INSULCLAD ENTRANCES

100 Series Single-Hung Windows (2008 to Present)

Primed Casement Windows (1932 to 1989)

350/500 Heavy Wall TM Entrances 1

Transcription:

SLIDING - GENERAL NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH THE FLORIDA UILDING CODE (FC), CURRENT EDITION. 2. GLAZING OPTIONS: (SEE ) 100 SW TH AVE. 3. APPROVED CONFIGURATIONS INCLUDE UT ARE NOT LIMITED TO: "XO", "OX", "XX", "OXO", "XXX", "OXXO", "XXXX", "PX", "PXX", "PXXX", "PXXXX", "PXXP", "PXXXXP", "PXXXXXXP", "PXXXXXXXXP" 2 TRACK, 3 TRACK, TRACK 0 PVC SLIDING 7" MAX. UNIT HEIGHT 3 1/2" MAX. PANEL HEIGHT 5/" MAX. PANEL WIDHT 1" FRAME WIDTH 1 5/" GLASS DLO X X X X A C D G H 6 1/2" GLASS DLO. DESIGN PRESSURE RATING (SEE 2): -NEGATIVE DESIGN LOADS ASED ON, TESTED PRESSURE AND GLASS TALES ASTM E-1300-0. -POSITIVE DESIGN LOADS ASED ON, TESTED PRESSURE, WATER INFILTRATION TEST PRESSURE AND GLASS TALES ASTM E-1300-0. 5. ANCHORAGE: THE 33 1/3% STRESS INCREASE HAS NOT EEN USED IN THE DESIGN OF THIS PRODUCT. SEE S - FOR ANCHOR DETAILS. WINDLOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 6. NOT APPROVED FOR IMPACT RESISTANCE. IMPACT PROTECTIVE SYSTEM IS REQUIRED IN WIND ORNE DERIS REGION. 7. ALL FRAMES ARE PROCESSED AND SCREWED TOGETHER. PVC VENTS ARE FULLY WELDED.. SERIES / MODEL DESIGNATION SGD-0.. THE DESIGNATION X AND O STAND FOR THE FOLLOWING: X = OPERALE SASH, O = FIXED SASH, P = POCKET/HOOKSTRIP 10. SECTION CALLOUTS APPLY TO ALL CONFIGURATIONS IN A SIMILAR LOCATION. UPDATED PER 201 FC EMK 03/2/15 A UPDATED PER 2010 FC TEF 11/01/11 Y: 11. WEEP SLOTS = 1/" x 1-1/" LOCATED 6" FROM OTH ENDS. F E A A TALE OF CONTENTS GENERAL NOTES & ELEVATIONS...1 COMPARATIVE ANALYSIS...2 SECTION VIEWS...3 OM & GLAZING DETAIL... EXTRUSIONS...5 TRACK WIDTHS...6 ANCHOR SCHEDULE & NOTES...7 INSTALLATION DETAILS...- MAX. PANEL SIZE DESIGN PRESSURE RATING IMPACT RATING -5/" x 3-1/2" SEE COMPARATIVE ANALYSIS CHART, 2 NONE () PANELS SHOWN, UNLIMITED NUMER OF PANELS IS ALLOWALE AS LONG AS INDIVIDUAL PANELS DO NOT EXCEED PANEL SIZE AS SHOWN. 123 JAARA AVE. PH. 1-30-157 GENERAL NOTES AND ELEVATIONS DRAWN Y: 1:30 1 OF

COMPARATIVE ANALYSIS YPASS 5 1/2 71 1/2 3 1/2 5 1/2 0 5/ 10 5/ 126 5/ 1 5/ 117 1/ 11 1/ 165 1/ 1 1/ 170 1/2 206 1/2 20 27 1/2 223 3/ 271 3/ Panel W. 30 3/16 36 3/16 2 3/16 3/16 30 3/16 36 3/16 2 3/16 3/16 30 3/16 36 3/16 2 3/16 3/16 30 3/16 36 3/16 2 3/16 3/16 30 3/16 36 3/16 Config. OX,XO OX,XO OX,XO OX,XO OXO OXO OXO OXO OXXO OXXO OXXO OXXO OXXXXO OXXXXO OXXXXO OXXXXO OXXXXXXO OXXXXXXO 0 A +70.0 / -125. +70.0 / -10. +70.0 / -1. +70.0 / -70.0 +70.0 / -125. +70.0 / -10. +70.0 / -1. +70.0 / -70.0 +70.0 / -125. +70.0 / -10. +70.0 / -1. +70.0 / -70.0 +70.0 / -125. +70.0 / -10. +70.0 / -1. +70.0 / -70.0 +70.0 / -125. +70.0 / -10. A +70.0 / -11.5 +70.0 / -103.2 +70.0 / -1. +70.0 / -70.0 +70.0 / -11.5 +70.0 / -103.2 +70.0 / -1. +70.0 / -70.0 +70.0 / -11.5 +70.0 / -103.2 +70.0 / -1. +70.0 / -70.0 +70.0 / -11.5 +70.0 / -103.2 +70.0 / -1. +70.0 / -70.0 +70.0 / -11.5 +70.0 / -103.2 0 A +70.0 / -10.0 +70.0 / -.6 +70.0 / -.6 +70.0 / -70.0 +70.0 / -10.0 +70.0 / -.6 +70.0 / -.6 +70.0 / -70.0 +70.0 / -10.0 +70.0 / -.6 +70.0 / -.6 +70.0 / -70.0 +70.0 / -10.0 +70.0 / -.6 +70.0 / -.6 +70.0 / -70.0 +70.0 / -10.0 +70.0 / -.6 7 A +70.0 / -.7 +70.0 / -6.2 +70.0 / -76. +70.0 / -70.0 +70.0 / -.7 +70.0 / -6.2 +70.0 / -76. +70.0 / -70.0 +70.0 / -.7 +70.0 / -6.2 +70.0 / -76. +70.0 / -70.0 +70.0 / -.7 +70.0 / -6.2 +70.0 / -76. +70.0 / -70.0 +70.0 / -.7 +70.0 / -6.2 YPASS 117 7/ 11 7/ 165 7/ 1 7/ 171 1/ 207 1/ 23 1/ 27 1/ 22 3/ 272 3/ 320 3/ 36 3/ Panel W. 30 3/16 36 3/16 2 3/16 3/16 30 3/16 36 3/16 2 3/16 3/16 30 3/16 36 3/16 2 3/16 3/16 Config. XXXX XXXX XXXX XXXX XXXXXX XXXXXX XXXXXX XXXXXX XXXXXXXX XXXXXXXX XXXXXXXX XXXXXXXX 0 A +70.0 / -125. +70.0 / -10. +70.0 / -1. +70.0 / -70.0 +70.0 / -125. +70.0 / -10. +70.0 / -1. +70.0 / -70.0 +70.0 / -125. +70.0 / -10. +70.0 / -1. +70.0 / -70.0 A +70.0 / -11.5 +70.0 / -103.2 +70.0 / -1. +70.0 / -70.0 +70.0 / -11.5 +70.0 / -103.2 +70.0 / -1. +70.0 / -70.0 +70.0 / -11.5 +70.0 / -103.2 +70.0 / -1. +70.0 / -70.0 0 A +70.0 / -10.0 +70.0 / -.6 +70.0 / -.6 +70.0 / -70.0 +70.0 / -10.0 +70.0 / -.6 +70.0 / -.6 +70.0 / -70.0 +70.0 / -10.0 +70.0 / -.6 +70.0 / -.6 +70.0 / -70.0 7 A +70.0 / -.7 +70.0 / -6.2 +70.0 / -76. +70.0 / -70.0 +70.0 / -.7 +70.0 / -6.2 +70.0 / -76. +70.0 / -70.0 +70.0 / -.7 +70.0 / -6.2 +70.0 / -76. +70.0 / -70.0 YPASS 5 13/16 7113/16 3 13/16 5 13/16 6 7/16 10 7/16 122 7/16 10 7/16 113 1/16 137 1/16 161 1/16 15 1/16 Panel W. 30 3/16 36 3/16 2 3/16 3/16 30 3/16 36 3/16 2 3/16 3/16 30 3/16 36 3/16 2 3/16 3/16 Config. XX XX XX XX XXX XXX XXX XXX XXXX XXXX XXXX XXXX 0 A +70.0 / -125. +70.0 / -10. +70.0 / -1. +70.0 / -70.0 +70.0 / -125. +70.0 / -10. +70.0 / -1. +70.0 / -70.0 +70.0 / -125. +70.0 / -10. +70.0 / -1. +70.0 / -70.0 A +70.0 / -11.5 +70.0 / -103.2 +70.0 / -1. +70.0 / -70.0 +70.0 / -11.5 +70.0 / -103.2 +70.0 / -1. +70.0 / -70.0 +70.0 / -11.5 +70.0 / -103.2 +70.0 / -1. +70.0 / -70.0 0 A +70.0 / -10.0 +70.0 / -.6 +70.0 / -.6 +70.0 / -70.0 +70.0 / -10.0 +70.0 / -.6 +70.0 / -.6 +70.0 / -70.0 +70.0 / -10.0 +70.0 / -.6 +70.0 / -.6 +70.0 / -70.0 7 A +70.0 / -.7 +70.0 / -6.2 +70.0 / -76. +70.0 / -70.0 +70.0 / -.7 +70.0 / -6.2 +70.0 / -76. +70.0 / -70.0 +70.0 / -.7 +70.0 / -6.2 +70.0 / -76. +70.0 / -70.0 SINGLE POCKETS 5 1/ 70 1/ 2 1/ 1/ 3/ 102 3/ 121 3/ 13 3/ 111 3/ 135 3/ 15 3/ 13 3/ 156 16 20 22 Panel W. 30 3/16 36 3/16 2 3/16 3/16 30 3/16 36 3/16 2 3/16 3/16 30 3/16 36 3/16 2 3/16 3/16 30 3/16 36 3/16 2 3/16 3/16 Config. PX / XP PX / XP PX / XP PX / XP PXX / XXP PXX / XXP PXX / XXP PXX / XXP PXXX / XXXP PXXX / XXXP PXXX / XXXP PXXX / XXXP PXXXX / XXXX PXXXX / XXXX PXXXX / XXXX PXXXX / XXXXP 0 A +70.0 / -125. +70.0 / -10. +70.0 / -1. +70.0 / -70.0 +70.0 / -125. +70.0 / -10. +70.0 / -1. +70.0 / -70.0 +70.0 / -125. +70.0 / -10. +70.0 / -1. +70.0 / -70.0 +70.0 / -125. +70.0 / -10. +70.0 / -1. +70.0 / -70.0 A +70.0 / -11.5 +70.0 / -103.2 +70.0 / -1. +70.0 / -70.0 +70.0 / -11.5 +70.0 / -103.2 +70.0 / -1. +70.0 / -70.0 +70.0 / -11.5 +70.0 / -103.2 +70.0 / -1. +70.0 / -70.0 +70.0 / -11.5 +70.0 / -103.2 +70.0 / -1. +70.0 / -70.0 0 A +70.0 / -10.0 +70.0 / -.6 +70.0 / -.6 +70.0 / -70.0 +70.0 / -10.0 +70.0 / -.6 +70.0 / -.6 +70.0 / -70.0 +70.0 / -10.0 +70.0 / -.6 +70.0 / -.6 +70.0 / -70.0 +70.0 / -10.0 +70.0 / -.6 +70.0 / -.6 +70.0 / -70.0 7 A +70.0 / -.7 +70.0 / -6.2 +70.0 / -76. +70.0 / -70.0 +70.0 / -.7 +70.0 / -6.2 +70.0 / -76. +70.0 / -70.0 +70.0 / -.7 +70.0 / -6.2 +70.0 / -76. +70.0 / -70.0 +70.0 / -.7 +70.0 / -6.2 +70.0 / -76. +70.0 / -70.0 100 SW TH AVE. 0 PVC SLIDING UPDATED PER 201 FC EMK 03/2/15 A UPDATED PER 2010 FC TEF 11/01/11 Y: DOULE POCKETS 11 1/2 13 1/2 162 1/2 16 1/2 167 3/ 203 3/ 23 275 3/ 221 26 317 365 27 1/ 33 1/ 3 1/ 5 1/ Panel W. 30 3/16 36 3/16 2 3/16 3/16 30 3/16 36 3/16 2 3/16 3/16 30 3/16 36 3/16 2 3/16 3/16 30 3/16 36 3/16 2 3/16 3/16 Config. PXXP PXXP PXXP PXXP PXXXXP PXXXXP PXXXXP PXXXXP PXXXXXXP PXXXXXXP PXXXXXXP PXXXXXXP PXXXXXXXXP PXXXXXXXXP PXXXXXXXXP PXXXXXXXXP 0 A +70.0 / -125. +70.0 / -10. +70.0 / -1. +70.0 / -70.0 +70.0 / -125. +70.0 / -10. +70.0 / -1. +70.0 / -70.0 +70.0 / -125. +70.0 / -10. +70.0 / -1. +70.0 / -70.0 +70.0 / -125. +70.0 / -10. +70.0 / -1. +70.0 / -70.0 A +70.0 / -11.5 +70.0 / -103.2 +70.0 / -1. +70.0 / -70.0 +70.0 / -11.5 +70.0 / -103.2 +70.0 / -1. +70.0 / -70.0 +70.0 / -11.5 +70.0 / -103.2 +70.0 / -1. +70.0 / -70.0 +70.0 / -11.5 +70.0 / -103.2 +70.0 / -1. +70.0 / -70.0 0 A +70.0 / -10.0 +70.0 / -.6 +70.0 / -.6 +70.0 / -70.0 +70.0 / -10.0 +70.0 / -.6 +70.0 / -.6 +70.0 / -70.0 +70.0 / -10.0 +70.0 / -.6 +70.0 / -.6 +70.0 / -70.0 +70.0 / -10.0 +70.0 / -.6 +70.0 / -.6 +70.0 / -70.0 7 A +70.0 / -.7 +70.0 / -6.2 +70.0 / -76. +70.0 / -70.0 +70.0 / -.7 +70.0 / -6.2 +70.0 / -76. +70.0 / -70.0 +70.0 / -.7 +70.0 / -6.2 +70.0 / -76. +70.0 / -70.0 +70.0 / -.7 +70.0 / -6.2 +70.0 / -76. +70.0 / -70.0 123 JAARA AVE. PH. 1-30-157 NOTE: IF SIZE INTENDED IS NOT SHOWN, USE NEXT LARGER SIZE. SILL RISER MAX. POSITIVE DP NONE +30 10 +70 NOTE: INSTALLATION W/ NO SILL RISER WITH DP +70 ALLOWED IN LOCATIONS WHERE WATER INFILTRATION RESISTANCE IS NOT REQUIRED. DRAWN Y: 1:1 2 OF

33 30 20 6 26 1 1 2 13 7 20 15 26 33 3 100 SW TH AVE. 0 PVC SLIDING 3 21 3 3 37 7 15 2 16 1 17 2 37 36 26 6 20 36 2 3 3 33 15 SECTION VIEW - PAIR OF ANCHORS AT EACH CLIP. SEE SHT FOR SPACING. UPDATED PER 201 FC EMK 03/2/15 A UPDATED PER 2010 FC TEF 11/01/11 Y: 7 36 1 2 2 23 1 3 27 36 11 7 12 3 22 1 3 FIXED PANEL ATTACHMENT FIXED PANEL VIEW 123 JAARA AVE. PH. 1-30-157 SECTION VIEWS DRAWN Y: 25 3 SECTION VIEW A-A 21 ITEMS NOT SHOWN FOR CLARITY: 10, 1 ITEMS NOT USED IN VERSION SHOWN: 23,2,27,31,32,35 ALTERNATE SILL VIEW - NO RISER MAX. POS. DP +30 NOTE: INSTALLATION W/ NO SILL RISER WITH DP +70 ALLOWED IN LOCATIONS WHERE WATER INFILTRATION RESISTANCE IS NOT REQUIRED. 1:3.33 3 OF

PARTS LIST ITEM PART # DESCRIPTION VENDOR MATERIAL 1 H-6032 Panel, Top/ottom/Sides PVC Mikron 2 H-603 Astragal PVC Mikron 3 H-60 Frame, Main 2 Track PVC Mikron H-60 Frame, Adder Track PVC Mikron 5 H-6100 Frame, Screen Track PVC Mikron 6 H-11 Interlock, Double Aluminum Keymark 7 H-176 Reinforcement, Panel Aluminum Keymark P-312 Tandem Roller Stainless Sullivan P-3302 WSTP., 0.330 x.17, Fin, Gray Ultrafab 10 SikaFlex 552 or Purfect Glaze "H" Sika / Henkel 11 P-3352 Setting lock Rubber Frank Lowe 12 P-3511 # x 1/2" Pan Phil Tek @ roller Steel Fastenal 13 P-3557 #10 x 2 Hex Washer, TEK, SS @ astragal Steel Fastenal 1 P-3756 #10 x 1 1/2 Pan Phil sms @ keeper Steel Fastenal 15 P-3767 #10 x 1" Hex Washer Tek @ interlock Steel Fastenal 16 P-37 Handle Kit Steel SI 17 P-372 3/" Keeper Steel SI 1 P-373 Mortise Lock Steel SI 20 P-26 # x 3/" Flat Phil Tek @ interlock Steel Fastenal 21 P-366 Dust Plug Ultrafab 22 P-7 Weep Cover Nylon M&M 23 S-157 Fixed Panel Cover Aluminum Keymark 2 S-161 Fixed Panel Clip Aluminum Keymark 25 S-1655 Roller Track Aluminum Keymark 26 S-161 Interlock Trim Cover Aluminum Keymark 27 S-1722 Fixed Panel Support Aluminum Keymark 2 S-1726 Reinforcement, Astragal Aluminum Keymark 2 S-126 Frame Filler Aluminum Keymark 30 S-166 Hook Strip Aluminum Keymark 31 S-17 MidRise for Screen Aluminum Keymark 33 S-10 Interior Cover Aluminum Keymark 3 S-10 MidRise Aluminum Keymark 36 S-6037 Glazing ead PVC Mikron 37 S-600 Track Filler PVC Mikron 3 S-601 Screen Track PVC Mikron 3 S-6101 Frame Filler PVC Mikron 1 # x 3" phil flat sms @ frame assm Steel Fastenal 2 GLASS SEE THIS 3 Gasket, left and right Frank Lowe PANEL CORNERS FULLY WELDED 1: 36 11 FRAME CORNERS MECHANICALLY FASTENENED 1: 10 1" OVERALL 3/16" TEMPERED 5/" AIRSPACE 3/16" TEMPERED PURFECT GLAZE "H" SIKAFLEX 552 13/16" GLASS ITE FRAME CORNERS WELDED TO MAX SIZE 120" x 6" 1: 100 SW TH AVE. 0 PVC SLIDING UPDATED PER 201 FC EMK 03/2/15 A UPDATED PER 2010 FC TEF 11/01/11 Y: 123 JAARA AVE. PH. 1-30-157 OM AND GLAZING DETAIL LINE ITEMS NOT USED: 1, 32, 35, 0 NOTE: ALL EXTRUSIONS ARE ALUMINUM 6063-T6 UNLESS OTHERWISE NOTED. DRAWN Y: 1:1 OF

5 1/" 2 7/" 3 2 3/" 2 3/" 1/" PVC MAIN FRAME - 60 PVC ADD-A-TRACK - 60 1/" 1 1 5 2 3/" 1/" PVC SCREEN TRACK - 6100 3 /16" 1 7/" 3 1/" 1 6 2 /16" 1/" INTERLOCK - 11 100 SW TH AVE. 0 PVC SLIDING PVC PANEL - 6032 5 3 3/" 1/" 2 5/" 3/" 2 7/" 5" 30 2" 3 1/" FIXED PANEL CLIP - 161 2 " 1" 1" PLAN VIEW - 161 UPDATED PER 201 FC EMK 03/2/15 A UPDATED PER 2010 FC TEF 11/01/11 Y: PVC ASTRAGAL - 603 REINFORCEMENT - 1726 HOOKSTRIP - 166 1 2 5/" 2 23 2 3 37 27 1/" 7/" 2 1 1/" 1 1/" 2 15/16" PANEL SUPPORT - 1722 FIXED PANEL COVER - 157 PVC FRAME FILLER - 600 MID RISE - 10 1 5/" 2 1/" 15/16" 7/" 7/" 7 1/" 7/16" 7/16" 2" 13/16" 25 26 2 3 1/" COVER - 161 FILLER - 126 PVC FILLER - 6101 TRACK - 1655 REINFORCEMENT - 176 NOTE: ALL EXTRUSIONS ARE ALUMINUM 6063-T6 UNLESS OTHERWISE NOTED. 5/" 2 3/16" MID RISE W/ SCREEN - 17 5/" /16" 7/" PVC SCREEN TRACK - 601 5/16" 31 33 3 2 INTERIOR COVER - 10 7/16" 1 1/" 36 GLAZING EAD - 6037 123 JAARA AVE. PH. 1-30-157 DRAWN Y: 1:2 EXTRUSIONS 5 OF

100 SW TH AVE. 2 TRACK FRAME 7/" 3 TRACK FRAME TRACK FRAME 0 PVC SLIDING 3 1/" 5 1/" 7 1 10 1/" FRAME W/O SCREEN TRACK UPDATED PER 201 FC EMK 03/2/15 A UPDATED PER 2010 FC TEF 11/01/11 Y: 2 TRACK FRAME 3 TRACK FRAME 6 7/16" 7/" 123 JAARA AVE. PH. 1-30-157 FRAME WITH SCREEN TRACK NOTE: INFINITE NUMER OF TRACKS ARE POSSILE WITHOUT SCREEN DRAWN Y: 1:2 TRACK WIDTHS 6 OF

6" MAX. (TYP.) 3" MAX. O.C. (TYP.) 3" MAX. O.C. (TYP.) LC LC LC ANCHOR @ MIDSPAN (TYP.) 6" MAX. (TYP.) 6" MAX. (TYP.) 100 SW TH AVE. 0 PVC SLIDING 1" MAX. O.C. (TYP.) HOOKSTRIP ANCHORS (TYP.) X X X X 1" MAX. O.C. (TYP.) SEE NOTE 2 UPDATED PER 201 FC EMK 03/2/15 A UPDATED PER 2010 FC TEF 11/01/11 Y: ANCHOR LAYOUT - (FLANGE) NOTES: 1. INSTALL TWO ANCHORS AT EACH INSTALLATION LOCATION. SILL ANCHOR SPACING SAME AS HEAD. INSTALL TWO ANCHORS AT EACH LOCATION IN HOOKSTRIP. 2. SHIM AS REQ AT EACH USING LOAD EARING SHIMS. MAX. ALLOWALE SHIM STACK TO E 1/". USE SHIMS WHERE SPACE GREATER THAN IS PRESENT. LOAD EARING SHIMS SHALL E CONSTRUCTED OF HIGH DENSITY PLASTIC OR ETTER. WOOD SHIMS ARE NOT ALLOWED. 3. ANCHOR TYPE, SIZE, SPACING AND EMEDMENT SHALL E AS SPECIFIED IN THESE DRAWINGS,,.. ALL S MUST E MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST E PROTECTED TO PREVENT REACTION. 5. S SHALL E IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT E USED IN SUSTRATES WITH STRENGTHS LESS THAN THE MINIMUM SPECIFIED IN TALE 1,. 6. ANCHOR EMEDMENT TO SUSTRATE SHALL E EYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS, EMEDMENT SHALL E EYOND WOOD UCKS, IF USED, INTO SUSTRATE - 1X UCKS ARE OPTIONAL. 7. A MINIMUM CENTER-TO-CENTER SPACING SHALL E MAINTAINED ETWEEN ALL FASTENERS: 2-7/16" FOR MASONRY, 2" FOR FIXED PANEL CLIPS (ALL SUSTRATES), 1" FOR WOOD AND METAL.. WOOD OR MASONRY OPENINGS, UCKS AND UCK FASTENERS SHALL E PROPERLY DESIGNED Y THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. SUSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TALE1,. CONCRETE AND MASONRY SUSTRATES MAY NOT E CRACKED.. SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL E DONE Y OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: FMA/AAMA 100(FIN WINDOWS), FMA/AAMA 200(FLANGE WINDOWS), FMA/WDMA 250(OX WINDOWS), FMA/AAMA/WDMA 300(EXTERIOR DOORS) 123 JAARA AVE. PH. 1-30-157 ANCHOR SCHEDULE AND NOTES DRAWN Y: 1:0 7 OF

SUSTRATE Y OTHERS PERIMETER SEALANT Y INSTALLER TYPICAL HEAD ANCHORAGE 2 7/16" MIN. EMEDMENT INTERIOR MIN. EMEDMENT 100 SW TH AVE. 0 PVC SLIDING CONTINUOUS DL 1/" EAD OF SEALANT POINTS ETWEEN FRAME AND SUSTRATE Y INSTALLER SEALANT UNDER SCREW HEAD Y INSTALLER PERIMETER SEALANT Y INSTALLER DO NOT COVER WEEP HOLES SUSTRATE Y OTHERS A 2 7/16" VERTICAL SECTION TYPICAL SILL ANCHORAGE MIN. EMEDMENT INTERIOR MIN. EMEDMENT SUSTRATE TYPE ANCHOR TYPE MIN. EMEDMENT CONCRETE (2.0 KSI MIN.) 3/16" ITW TAPCON 1" 3" CONCRETE (2.5 KSI MIN.) 3/16" ELCO ULTRACON 1-3/" 1" HOLLOW OR GROUT-FILLED CMU (ASTM C-0) 3/16" ELCO ULTRACON 1-1/" 2-1/2" 2X MIN. SOUTHERN PINE (G=0.55) 3/16" ITW TAPCON OR ELCO ULTRACON 1-3/" 7/" 2X MIN. SOUTHERN PINE (G=0.55) #10 WOOD SCREW 1-3/" 7/" 16 GAUGE (0.060") MIN. STEEL STUD (33 KSI YIELD MIN) 1/" ALUM. (6063-T5 MIN.) OR 1/" STEEL (33 KSI MIN.) FIXED PANEL CLIP ANCHORS INTO CONCRETE (2.0 KSI MIN.) OR HOLLOW OR GROUT-FILLED CMU (117 PCF MIN.) TALE 1: APPROVED INSTALLATION FASTENERS #10-16 HILTI KWIK-FLEX OR ITW TEKS SELF-DRILLING SCREW #10 GRADE 5 SELF-TAPPING / DRILLING SCREW FULL THREAD THRU 0.060" FULL THREAD THRU 0.125" 3/16" ITW TAPCON 1" 3" CONTINUOUS DL 1/" EAD OF SEALANT POINTS ETWEEN FRAME AND SUSTRATE Y INSTALLER HORIZONTAL SECTION HOOK STRIP 17 7/" MAX. O.C. (TYP.) FIXED PANEL CLIP CLIP ANCHORS MUST E LOCATED A MINIMUM DISTANCE OF 3" AWAY FROM ANY MAIN FRAME ANCHOR. PERIMETER SEALANT Y INSTALLER MIN. EMEDMENT HOOK STRIP SHIM AS REQUIRED TO MEET INTERIOR TRACK FACE SUSTRATE Y OTHERS 12" MAX. (TYP.) FIXED PANEL CLIP DETAIL SUSTRATE Y OTHERS NOTE: FIXED PANEL CLIP ANCHORS INTO WOOD OR METAL SHALL FOLLOW THE ANCHOR TYPE, MIN. EMEDMENT AND MIN. EDGE DISTANCE LISTED IN TALE 1. 1/2" 1/2" C HORIZONTAL SECTION TYPICAL JAM ANCHORAGE 2 7/16" TWO ANCHORS PER FIXED CLIP THROUGH PRE-DRILLED HOLES D HORIZONTAL SECTION FIXED PANEL ANCHORAGE FIXED PANEL MIN. EMEDMENT FIXED PANEL EDGE DIST. UPDATED PER 201 FC EMK 03/2/15 A UPDATED PER 2010 FC TEF 11/01/11 123 JAARA AVE. PH. 1-30-157 DRAWN Y: 1:2.63 Y: OF INSTALLATION DETAILS 2 TRACK

CONTINUOUS DL 1/" EAD OF SEALANT POINTS ETWEEN FRAME AND SUSTRATE Y INSTALLER MIN. EMEDMENT, SHT 100 SW TH AVE. PERIMETER SEALANT Y INSTALLER DO NOT COVER WEEP HOLES SUSTRATE Y OTHERS, SHT, SHT E VERTICAL SECTION 3 TRACK SILL EAD OF SEALANT ETWEEN SILL RISER AND FRAME Y INSTALLER MIN. EMEDMENT, SHT, SHT SEALANT UNDER SCREW HEAD Y INSTALLER, SHT G HORIZONTAL SECTION 3 TRACK JAM PERIMETER SEALANT Y INSTALLER SUSTRATE Y OTHERS, SHT CONTINUOUS DL 1/" EAD OF SEALANT POINTS ETWEEN FRAME AND SUSTRATE Y INSTALLER MIN. EMEDMENT, SHT 0 PVC SLIDING UPDATED PER 201 FC EMK 03/2/15 A UPDATED PER 2010 FC TEF 11/01/11 Y: CONTINUOUS DL 1/" EAD OF SEALANT POINTS ETWEEN FRAME AND SUSTRATE Y INSTALLER EAD OF SEALANT ETWEEN SILL RISER AND FRAME Y INSTALLER CONTINUOUS DL 1/" EAD OF SEALANT AROUND PERIMETER @ ALL INDICATED POINTS ETWEEN FRAME AND SUSTRATE Y INSTALLER PERIMETER SEALANT Y INSTALLER DO NOT COVER WEEP HOLES SUSTRATE Y OTHERS, SHT MIN. EMEDMENT, SHT 123 JAARA AVE. PH. 1-30-157, SHT F VERTICAL SECTION TRACK SILL, SHT SEALANT UNDER SCREW HEAD Y INSTALLER, SHT H HORIZONTAL SECTION TRACK JAM PERIMETER SEALANT Y INSTALLER SUSTRATE Y OTHERS, SHT INSTALLATION DETAILS 3 & TRACK DRAWN Y: 1:2.63 OF