SPRAYTECS Series UP High Velocity Directional Spray Nozzles, Open, Non-Automatic. Suitable for Water Spray fixed systems.

Similar documents
Directional Spray Nozzles, Open, with Strainers High Velocity General Description

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

Type D3S PROTECTOSPRAY Directional Spray Nozzles, Open, Medium Velocity General Description. Technical Data. Page 1 of 6 AUGUST 2018 TFP804

Type EA-1 PROTECTOSPRAY Directional Spray Nozzles, Automatic, Medium Velocity General Description

MODELS F822 THRU F834

MODEL: HV-AS & HV-BS TECHNICAL DATA : MAINTENANCE DESCRIPTION PRESSURE (3/4 NPT OPTIONAL)

Data Sheet High Velocity Water Spray Nozzle. Issue B. Rapidrop Global. Ref: SPTDHV/E TECHNICAL DATA MAINTENANCE DESCRIPTION

WATER SPRAY NOZZLE DATA SHEET

model E Spray nozzles vk810 - vk817

HIGH VELOCITY WATER SPRAY NOZZLE (BRASS)

Data Sheet 11.2 Issue B

TECHNICAL DATA SHEET. Medium Velocity Water Spray Nozzle. Page 1. Description. Technical and Environmental Specification. Installation & Maintenance

TECHNICAL DATA VK810 (65 ) VK811 (80 ) VK812 (95 ) VK813 (110 )

Data Sheet 11.1 Issue A

MEDIUM VELOCITY WATER SPRAY NOZZLE

MEDIUM VELOCITY WATER SPRAY NOZZLE

Data Sheet Issue E

FRAME STYLE SPRAY NOZZLES TECHNICAL DATA

TECHNICAL DATA OBSOLETE

Model DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Electric Actuation

GW THERMOCOOL NOZZLE STRUCTURAL STEEL PROTECTION

Model RM-1 Riser Manifold Commercial and Residential General Description

Data Sheet 3.03 Issue D

Data Sheet 3.01 Issue C

SOLID CONE SPRAY NOZZLES TECHNICAL DATA

Technical Data. Sizes 2 in. to 24 in. (DN50 to DN600) Approvals UL and ULC Listed FM Approved

with the specific application. Always read and understand the installation

Instructions for Installation, Operation, Care and Maintenance

Instructions for Installation, Operation Care and Maintenance

Worldwide Contacts.

Q= C. v P S Refer to Table 1 for part numbers and shipping weights. Accessories: Table 1: Valve Part Numbers and Specifications

Mounting and Operating Instructions EB 5863 EN. Electric Control Valves. Pneumatic Control Valve

B21 Series BASOTROL Gas Valve

Data Sheet 3.11 Issue F

TECHNICAL DATA. Viking Technical Data may be found on Style: 90 Degree Pattern (inlet to outlet)

007 Tank Monitor. WARNING Never use with gasoline or highly flammable liquids.

GW M5 WATER MIST NOZZLE K-5, LOW PRESSURE, NON-AUTOMATIC

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil

TECHNICAL DATA 1-1/2 (dn40)

DELUGE VALVE MODEL: SD-DVA TECHNICAL DATA : VALVE OPERATION TRIM DESCRIPTION DESCRIPTION PRESSURE THREADED OPENING

Users Manual Professional Series Direct Drive Pump.25-2 GPM Series Safety, Operating, Installation, and Maintenance Instructions

ENGINEERING MANUAL PRESSURE STEAM HUMIDIFIERS

DELUGE VALVE DATA SHEET

Worldwide Contacts. Technical Data

TRAINING BULLETIN TOOLS 7 December, 1978 HOSE NOZZLES (HAND HELD) 1. NOZZLE NOMENCLATURE AND IDENTIFICATION

PENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

1-1/2 Inch (DN40) 9 lb (4,1 kg) Groove Groove 1 8 lb (3,6 kg) Flange Groove 1 N/A N/A. Flange Flange N/A N/A

NOZZLETECH INC. INSTRUCTION MANUAL CEV10 01/31/ C EAST COLONIAL DRIVE ORLANDO, FL USA

Model CV-1FR Grooved-End Riser Check Valves 2 Inch to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data

50:1 Grease Pump Kits

DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Wet Pilot Actuation General Description

DV-5 Deluge Valve Aluminium Bronze Diaphragm Style General Description

Owner s Information Manual

Technical Data. Sizes 2 12 Inch (DN50 DN300)

INSTALLATION/OPERATION/MAINTENANCE INSTRUCTIONS FOR ARCHON MODELS WD2010L, WD2010, WD2010H WASHDOWN STATIONS. ARCHON Industries, Inc.

Technical Data. UL Listing is based on the following criteria:

STYLE 3462 FORESTRY BUMPER MONITOR INSTALLATION, OPERATING and MAINTENANCE INSTRUCTIONS

TECHNICAL DATA. Q= C v P Cv = Flow Factor (GPM/1 PSI P)

Mounting and Operating Instructions EB 5894 EN. Electric control valves with jet pump. Flanged version of valve with jet pump

NOZZLETECH INC. INSTRUCTION MANUAL CEV00 01/31/ C EAST COLONIAL DRIVE ORLANDO, FL USA

D-023 PN 16 / 25. Combination Air Valve for Wastewater PATENTED. Description. Applications. Operation. Main Features

I-VICFLEX.AB7 VicFlex Sprinkler Fittings for Ceiling Suspension Systems STYLE AB7

DV-5a Automatic Water Control Valve Single Interlock Preaction Fire Protection Systems 1-1/2 Inch to 8 Inch (DN40 to DN200) General Description

Mounting and Operating Instructions EB 8048 EN. Type and Type Pneumatic Control Valves Type 3249 Aseptic Angle Valve

PowerFLO 7800 Series 12 Volt DC Motor-Driven Diaphragm Pumps

Instructions for Installation, Operation, Care and Maintenance

Elgin Hydraulic Clutch-Brake ECB-240, Product Number FORM NO. L F FORM NO. L F-0704

Wet pipe low flow foam/water manifold system

SYSTEM TB 1000 BULK ADHESIVE APPLICATOR INSTRUCTION FOR SET UP AND OPERATION SYSTEM TB1000

Right Angle Nozzle Assembly

BLACKMER BYPASS VALVES

Hollow Cone Spray Nozzles Series

Model F1 Model F1 Recessed Standard Response Sprinklers

CIRCLE SEAL CONTROLS

Listings and Approvals. G5 QR Gasket culus QR G5 SR Gasket culus, FM SR G5

mirage standard and Qr concealed pendent sprinkler vk462 and hp sprinkler vk463 (K5.6)

TECHNICAL DATA. Trimpac 244a. April 15, 2011

TECHNICAL DATA. Q= C v P S

Tank Foam Generator OPERATION AND MAINTENANCE

M-3025CB-AV Fuel Pump

Mounting and Operating Instructions EB 8039 EN. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve

SDM320D / SDM320A. Single phase din rail meter SDM320D / SDM320A user manual

D-040 PN 16 D-040-C PN 16. Combination Air Valve. Description. Applications. Operation. Main Features

DIESEL EXHAUST FLUID PUMP MOTOR ASSEMBLY REPLACEMENT GUIDE

TECHNICAL DATA. Table Standard Materials

Polypropylene Piston Drum Pumps

original operating manual Operating manual Translation of the Item-No.: ,

VERSAFLOW MAG 4000 Quick Start

EBS PRODUCTS

PROMAG SR SERIES SEAL-LESS CENTRIFUGAL PUMPS

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

18 KG MOBILE SODA BLASTING UNIT

PowerFLO 5800/5900 Series

SubDrive Inline Constant pressure controller Additional information for Australia, NZ TOLL FREE HELP 1300 FRANKLIN

DIKE AND SPILL PROTECTION

Full cone nozzles.

Installation & Design Maintenance for ILBP System

50 Gallon Skid Sprayer

Mounting and Operating Instructions EB 5868/5869 EN

Transcription:

Spraytecs technologies ltd SPRAYTECS Series UP High Velocity Directional Spray Nozzles, Open, Non-Automatic. Suitable for Water Spray fixed systems. Technical Data General Description The SPRAYTECS Series UP are high velocity, open (non-automatic) directional spray nozzles incorporating individual swirlers to obtain directional water spray. They are expressely designed for use in water spray fixed systems for fire protection applications, and are suitable when a high velocity water application is required, such in case of protection of flammable liquids. These Series UP spray nozzles can be equipped (as option) with an Inlet Strainer and/or (as option) a Dust Cap against dust and insect infestation as better explained in the section: Design Criteria. SPRAYTECS Series UP are availables in brass or stainless steel, and have a spray pattern related with different characteristics and dimensions of the orifice. When water reaches the nozzle, flows through and over the internal swirl. This causes the swirling of water, starting with an initial rotational movement. The design of the internal swirl assures better directionality and relative high velocity to the drops that come out the nozzle orifice. The result is a solid conical spray pattern of water drops, discharged in the design defined area. The spray nozzles expressly designed for High Velocity performances are used in water spray fixed systems for the protection of hazards as flammable liquids and gas storage tanks, diesel engines and diesel storage tanks, lube oil systems, oil fire boilers, circuit breakers, conveyor systems, chemical process equipments, oil filled transformers and similar hazards. These SPRAYTECS UP Series spray nozzles are able to quickly extinguishing the oil fires by emulsification, smothering, cooling. The high velocity spray nozzles in fixed water spray systems have good cooling effects on surfaces, so the possibility of reignition after a fire extinguishing action is minimized. Effects of concentration of chemicals, ambient temperature, and gas/chemical velocity should be considered about the corrosive nature to which spray nozzles may be exposed. We recommend that the end user could be advised about compatibility between corrosive environments and materials of construction of the spray nozzles. IMPORTANT Always read and refer to Technical sections: Design Criteria, Installation and Maintenance (here in this document in next pages) before handling and installation of these water spray, sprinkler systems and components. The products described herein must be installed and maintained in compliance with all recommendations of this document. Improper handling, installation or maintenance can create damages to the sprinkler/water spray system and fail to operate in a fire situation or cause to operate prematurely with dangerous effects. The sprinkler/water spray owner is the sole responsible about fire protection system and devices in good operating conditions. The installing contractor or sprinkler/spray nozzle manufacturer should be contacted about any information need. Page 1 of 5 JULY 2014 Series UP

Technical Data Approvals Series UP are tested under European Standards EN 12259-1 Maximum Working Pressure 350 psi (24,2 bar) Water Distribution Optimal flow pressure is between 30 to 90 psi (2,1 to 6,2 bar). Refer to the figures below in this document. Discharge Coefficient K-Factor Please refer to the figure on the left in this page. Fig. 1 : Water Spray Nozzle UP Series Codes, Dimensions, Wrench sizes and K-factor Phisical Characteristics (Brass) Body: Brass Swirl: Brass Phisical Characteristics (SS 316L) Body: Stainless Steel AISI 316L Swirl: Stainless Steel AISI 316L Dimensions Please refer to the figure on the left in this page. Thread Connection ½ NPT Male or ½ BSPT Male Page 2 of 5 JULY 2014 Series UP

Notes (Water Distribution Design): 1. The shapes of the Global Spray Area and Design Spray Area of Protection, Global and Design Spray Profile remain essentially the same over the showed maximum heights of nozzle positioning. 2. Design Data here indicated are related only to the indicated pressures. In case of different pressures applied, please ever consult Spraytecs Technologies Ltd. We will happy to support and confirm the project basic data with your Fire Fighting System Engineers. Every nozzle on the market can have a different distribution depending from the applied pressure. Ever contact the manufacturer is a best practice. 3. Design data applies to a maximum wind of 24 km/h (15 MPH). Fig. 2a : Water Distribution Design Data and Design Criteria Fig. 2b : Water Distribution Design Data of UP nozzle K23 at 2 bar Page 3 of 5 JULY 2014 Series UP

Design Criteria Nozzle Positioning The nominal global (overall) spray area patterns, the maximum heights of positioning from the protected surface (axial distances), the spacing are showed in Fig. 2a, Fig. 2b, Fig. 2c. The minimal residual pressure of 2 bar (29 psi) can be applied in most applications. Anyway we recommend to use a minimum residual pressure of 3,5 bar (51 psi) in all applications requiring higher velocity water discharge, as those specifying rapid extinguishment of oil fires by emulsification effect. To obtain the total impingement on all surfaces we recommend to consider in your system design the showed dimensions (in fig. 2a, fig. 2b, fig. 2c) of Design Distance Profile and Design Spray Area of Protection for the axial distances/heigths of nozzle positioning. The squared Design Spray Area of Protection inside the circular Global Spray Area is defined in Fig. 2a. The maximum recommended heights of nozzle are established on maintaining the specified spray patterns under a maximum wind speed of 25 km/h (15 MPH). Main Pipeline Strainers Main pipeline strainers are required for systems utilizing Spraytecs UP Nozzles, because their internal waterways are less than 9.5 mm (3/8 inch). Dust Caps. The optional Dust Caps are suitable for indoor and outdoor use over a temperature range of -50C to 68C ( - 58F to 154F ). To assure the release of the Dust Cap, a minimum flowing pressure of 1.0 bar (15 psi) is required. Fig. 2c : Water Distribution Design Data of UP nozzle K23 at 4 bar Installation Spraytecs Series UP Nozzles must be installed as specified in this section. General Instructions A leak tight in a ½ inch BSPT or NPT male nozzle joint should be obtained by applying a minimum to maximum torque of 10 to 19 Nm (7.3 to 14 ft-lbs). Higher levels of torque may damage the nozzle inlet and cause malfunctioning of the nozzle. Phase A). With pipe thread sealant applied to the pipe threads, hand tighten the nozzle into the nozzle fitting. Phase B). Using a fixed wrench of appropriate size, tighten the nozzle in the nozzle fitting. The wrench must be of the size specified as in Fig. 1. Care and Maintenance Spraytecs Series UP Nozzles must be maintained in accordance with the below specifications. Before to start maintenance works and therefore closing a fire protection system main control valve on the fire protection system that it controls, obtain permission from the proper authorities to shut down the fire protection system and notify all personnel who may be affected by this operation. Sprinklers/Nozzles which are found damaged, leaking or with sign of corrosion must be replaced. Moreover they must never be coated, painted, plated or anyway altered after leaving the factory. Sprinklers/Nozzles that have been exposed to corrosive effect of Page 4 of 5 JULY 2014 Series UP

combustion, but have not operated, should be substituted. Sprinklers/Nozzles that seems modified or not in perfect conditions must be replaced. During maintenance operation is mandatory to avoid any damage to the sprinklers/nozzles, as water dropping, wrench twist/slippage, striking, or similar situations, because in such cases must be replaced. Water spray fixed systems are mandatory as subjects to be inspected, to be tested and to be maintained by a qualified Inspection Service in accordance with the local requirements and/or national codes. Water spray fixed systems for fire protection needs of a regularly performed planned service of maintenance by trained operators. The service operations must inspect nozzles for proper spray performance during the water flow trip tests of the system. Moreover it is recommended that nozzles must be checked about broken, damages or signs of impaired protection, and this operation should be planned weekly or more frequently. Ever the local availability of sprinklers/nozzles of the same type should be assured, in the way to permit that the fire protection system will work as intended in the unfortunate case of fire. The owner of the fire protection system and of the fire protection devices, is responsible for the inspection, testing and maintenance in total compliance with this document, as well as with the applicable standards of the applicable Fire European Standards (EN 12259-1), the National Fire Protection Association (NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the installing contractor or Spraytecs Technologies Ltd regarding any questions. Copyright 2014 Spraytecs Technologies Ltd. All rights reserved. Page 5 of 5 JULY 2014 Series UP